Perimeter Access Guarding

BeamSafe II
®

BS2

Rev. 8.12

Long-Range, Single-Beam Safety Control
•
•
•
•
•
•

60 m (200 ft.) range
Four possible transmit codes eliminate crosstalk from multiple units in the same area
Signal strength indicator and integral “Gun Sight” allow easy installation
No interconnecting cables required, which speeds long-range installations
Adjustable mounting brackets allow easy alignment
Three models available:
– Relay output with 24 VDC power input
– Relay output with 85 to 250 VAC power input
– Solid-state output with 24 VDC power input
• Switch-selected Automatic Start or Start/Restart Interlock operation
• Lens heater
• Designed in accordance with IEC61496, EN954-1 and
ANSI B11.19-2003

Specifications
Performance
Protected Height:
Operating Range:
Beam Diameter:
Maximum Response Time:
<0.035 seconds for all models
DC Models Input Power:

Construction:
Operating Temperature:
Protection Category:
Agencies:

Shown here
with optional
quick-disconnect
cable kit.

C

US

File No. LR90200

Single Beam
0.3 to 60 m (1 to 200 ft.)
31 mm (1.2 in.)

24 V ±10% (negative ground)
Receiver/Relay Output: 0.45 A Max
Receiver/SS Output: 0.80 A Max
Transmitter: 0.17 A Max

AC Models Input Power:  100
to 230 VAC ±10%, 50/60 Hz;

Effective Aperture Angle:
Frequency Selection:
Diagnostics:
Output:

C

Receiver 115 VAC: 16 VA
Receiver 230 VAC: 25 VA
Transmitter 115 VAC: 10.5 VA
Transmitter 230 VAC: 20 VA
2.5° maximum half angle
4 non-interfering codes, all models
Built-in diagnostic indicators
Relay Output Version: Two relays with force-guided contacts, NO rated 4 A
at 115 VAC, 200 W switched power (2.0 kVA). DC Loads are limited to 100 V
maximum. Estimated mechanical life is 50,000,000 operations. Electrical  life is
typically 1,000,000 operations at 200 VA.
Auxiliary Monitoring Relay: 400 V AC/DC maximum, 0.1 A; total power 180 mW
maximum.
Solid-State Output Version: Two safety solid-state relay outputs. Each output
sources (PNP) up to 0.25 A at 24 VDC.
Polyester powder-painted aluminum body. Anodized aluminum end-caps.
0 to 55°C (32 to 131°F)
IP65; NEMA 4
Designed in accordance with IEC 61496, type 4 and UL/CSA requirements.

Specifications are subject to change without notice.

Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357	 Canada Tel. 1/866/986-6766	 www.sti.com

Description
The BeamSafe II is a
long-range single-beam safety
control designed for perimeter
and access guarding. “Diverse
redundant” microprocessor
design provides safe, control
reliable operation.
A BeamSafe II system
consists of one transmitter
and one receiver. No interconnecting cables or separate
control enclosure are required.
Mounted on the receiver, four
separate visible indicators
provide instant information on
system clear, blocked or interlocked status as well as signal
strength. Additional diagnostic
indicators on the receiver
provide codes to assist with
troubleshooting. Output options
include redundant solid-state
or force-guided relays located
in the receiver.
Immunity to weld flash and
ambient light are enhanced
by coding the infrared beam.
This feature also eliminates
interference from other BeamSafe II units installed in close
proximity. A tight beam angle
reduces problems associated
with reflective surfaces. The
Beamsafe II’s built-in lens
heater is effective in environments where condensation
may form on the transmitter or
receiver lens.
C1

BeamSafe® II

Perimeter Access Guarding

Applications	

(mm/in.)

Perimeter Guarding

Long-Range
Perimeter Guarding

Shown here with one transmitter and
receiver. Mirrors are used to form two
beams and also turn corners.

Double Bounce

Two transmitter/receiver pairs using two
mirrors and Omron STI mounting stands to
direct the beam around a corner.

1 to 59 ft
0.3 to 18 m

This configuration guards access to
hazardous work cells. One transmitter and
receiver combined with two Omron STI 4
in. mirrors and mounting brackets.

1 to 176 ft
0.3 to 53 m

C

1 to 75 ft
0.3 to 23

Transmitter

45° Mirror
Transmitter

36 in
900 mm

Receiver

36 in
900 mm

16 in
400 mm

Floor

Transmitter

Transmitter

Receiver

36 in
900 mm
45° Mirror

16 in
400 mm

Receiver

Receiver

Floor

16 in
400 mm

Floor

Dimensions	

(mm/in.)

BeamSafe II, Relay Output Version
60
2.36

B

C
R

108
4.25

74.3
2.93

77.9
3.07

MOUNTING HOLES (4) FOR
ALTERNATE REAR MOUNTING

BeamSafeII

R

BeamSafeIIReceiver

25.4
1.00

F1
F2

158.8
6.25

168.7
6.64 REF.

ALTERNATE REAR
CABLE ENTRY
SIDE VIEW

FRONT VIEW

MOUNTING BRACKET
SURFACE MTG "FOOTPRINT" DIMENSIONS
55.9
35°
13.0 (X2)
2.20
0.55
R27.3
1.075

35.1
1.38 50.8
2.00
3.9 (X3)
0.27
32.4
1.28

C2

A
REF.

C
L

6.9 DIA.
0.27

BeamSafe II,
Relay Output Version
Unit Length Dims
AC Receiver
AC Transmitter
DC Receiver
DC Transmitter

BACK/REAR VIEW

±
Dimensions: mm 0.25
IN ± 0.01

SLOTS FOR
T-NUTS

A

B

C

239.6
9.44
197.7
7.79
197.7
7.79
197.7
7.79

178.9
7.05
137.2
5.40
137.2
5.40
137.2
5.40

160.1
6.31
118.4
4.66
118.4
4.66
118.4
4.66

Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357	 Canada Tel. 1/866/986-6766	 www.sti.com

ADJUSTABLE
MOUNTING
BRACKET

24.4
0.96

TOP VIEW

BOTTOM VIEW

BeamSafe® II

Perimeter Access Guarding

Dimensions (continued)	

(mm/in.)

BeamSafe II,
Solid-State Output Version, Tranmitter and Receiver

R

88.9
3.50

55.2
2.17

191
REF.
7.52
93.0
3.66

111.8
4.40

50.8
2.00

This drawing is available in
CAD format at www.sti.com

MOUNTING HOLES (4) FOR
ALTERNATE REAR MOUNTING

BeamSafeII

BeamSafeII Receiver

C

139.7
5.50

168
REF.
6.62
ALTERNATE REAR
CABLE ENTRY
SIDE VIEW

FRONT VIEW

BACK/REAR VIEW
SLOTS FOR
T-NUTS

MOUNTING BRACKET
SURFACE MTG "FOOTPRINT" DIMENSIONS
47.6
35°
13.0 (X2)
1.875
0.55
R27.3
1.075

32.4
1.275

ADJUSTABLE MOUNTING BRACKET

20.5
0.81

35.1
1.38 50.8
2.00

6.9 (X3)
0.27
C
L

25.4
1.00

±
Dimensions: mm 0.25
IN ± 0.01

BOTTOM VIEW

TOP VIEW

Ø6.9
0.27

Wiring
Two Normally Open Contacts AC Voltage Connections

BS2RAC

MPCE 1

100 to 230 VAC
8

Output A

2

3

J6

1

Output B
Auxiliary Monitor Relay
(Non Safety Output)

J7

(N.C.)
Start

Arc Suppressor
3

6
5
11
12
1
2

1`

WARNING: Arc suppression devices
should only be installed across the
coils of the machine control relays.
Never install Arc Suppression
devices directly across the control
output contacts of the BeamSafe.
An arc suppression device installed
across the contacts may fail with a
short circuit and will result in an
unsafe condition.

2

These relay contacts must be forceguided contacts.

3

User supplied over current
protection, 4A max.

1`

MPCE 1

Arc Suppressor
3

MPCE 2

To Machine Control Stop Circuit

7

Earth/Ground

2

1`

MPCE 2

No external voltage is
to be applied to
terminals 1 & 2.
Damage to unit will occur.

Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357	 Canada Tel. 1/866/986-6766	 www.sti.com

C3

BeamSafe® II

Perimeter Access Guarding

Wiring (continued)
Normally Open/Normally Closed Connection Diagram

BS2RAC

MPCE 1

100 to 230 VAC
Earth/Ground

8

Arc Suppressor
3

J6

Output A

3

1`

MPCE 1

2

1`

WARNING: Arc suppression devices
should only be installed across the
coils of the machine control relays.
Never install Arc Suppression
devices directly across the control
output contacts of the BeamSafe.
An arc suppression device installed
across the contacts may fail with a
short circuit and will result in an
unsafe condition.

2

These relay contacts must be forceguided contacts.

1

Arc Suppressor

6

Output B

J7

MPCE 2

To Machine Control Stop Circuit

7

C

2

3

5

Auxiliary Monitor Relay
(Non Safety Output)

11

(N.C.)
Start

1

12

1`

MPCE 2

No external voltage is
to be applied to
terminals 1 & 2,
Damage to unit will occur.

2

User supplied over current
protection, 4A max.

3

Two Normally Open Contacts DC Voltage Connections (Solid-State Output Model)
+24

-24

24 VDC

MPCE 1

BS2RC24

2

MPCE 2

To Machine Control Stop Circuit
6

Earth/Ground
Sourcing

J5

7

Arc Suppressor
Output A

3

3

1

3

1`

MPCE 1

Arc Suppressor
Output B

1

1

MPCE 2

2

Start (N.C.)
Signal Return

C4

4
5

No external voltage is
to be applied to
terminals 4 & 5;
Damage to unit will occur.

Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357	 Canada Tel. 1/866/986-6766	 www.sti.com

WARNING: Arc suppression devices
should only be installed across the
coils of the machine control relays.
Never install Arc Suppression
devices directly across the control
output contacts of the BeamSafe.
An arc suppression device installed
accros the contacts may fail with a
short circuit and will result in an
unsafe condition.

2

These relay contacts must be force
guided contacts.

3

If load is less than 50 mA a resistor
must be installed across the load.

BeamSafe® II

Perimeter Access Guarding

Wiring (continued)	

(mm/in.)

Two Normally Open Contacts 24 VDC Voltage Connections

BS2R24

MPCE 1

24 VDC
Earth/Ground

MPCE 2

To Machine Control Stop Circuit

6

J2

2

3

C
6

Output A

J1

4

Output B
J2

Auxiliary Monitor Relay
(Non Safety Output)
(N.C.)
Start

Arc Suppressor

5
3

2
1
1
2
4
5

1`

WARNING: Arc suppression devices
should only be installed across the
coils of the machine control relays.
Never install Arc Suppression
devices directly across the control
output contacts of the BeamSafe.
An arc suppression device installed
accros the contacts may fail with a
short circuit and will result in an
unsafe condition.

2

These relay contacts must be forceguided contacts.

3

User supplied over current
protection, 4A max.

MPCE 1

Arc Suppressor
3

1`

1`

MPCE 2

No external voltage is
to be applied to
terminals 4 & 5.
Damage to unit will occur.

Accessories	

(mm/in.)

Front Surface Glass or
Stainless Steel Mirror

Brackets

MIR45-FG and MIR45-SS

MIR45BKT

38.1
1.500

BSMK

MIRROR
STAINLESS STEEL
OR
GLASS

MIRROR
SUPPORT
BLOCK

MIRROR
STAND
PIPE

OR

MOUNTING TABS
(4 PLACES)
38.35
1.510

Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357	 Canada Tel. 1/866/986-6766	 www.sti.com

C5

BeamSafe® II

Perimeter Access Guarding

Accessories	

(mm/in.)

Laser Alignment Tool

BS2LA

Laser Level Unit
Target Clip

C

BEAMCHECK

BeamSafe II

BeamSafe II
Laser Mounting Adaptor

Ordering
Model No.

Description

BS2X24

Transmitter, 24 VDC

BS2XAC

Transmitter, 85 to 250 VAC, 50/60 Hz

BS2XC24

Transmitter, 24 VDC, Compact Size (This is not
compatible with QDX and QDR series connectors)

BS2R24

Receiver, 24 VDC, Relay Output

BS2RAC

Receiver, 85 to 250 VAC, 50/60 Hz, Relay Output

BS2RC24

Receiver, 24 VDC, Compact Size, Solid-state Output
(This is not compatible with QDX and QDR series
connectors)

Accessories

C6

MIR45-FG

4 in. mirror for use with MIR45BKT-Front Surface Glass

MIR45-SS

4 in. mirror for use with MIR45BKT-Stainless Steel

MIR45BKT

Bracket for mounting above mirrors at 45° angles for
use in “double bounce” applications (kit mounts one
mirror)

BSMK

Bracket kit. Allows mounting of one BeamSafe II
transmitter and one BeamSafe II receiver to Omron STI
mounting stands

MIRS-04

4 ft. stand for mounting mirrors and BeamSafe II units

MIRS-06

6 ft. stand for mounting mirrors and BeamSafe II units

QDR-12

12 ft., 12-conductor receiver cable, with quickdisconnect socket

QDR-20

20 ft., 12-conductor receiver cable, with quickdisconnect socket

QDR-35

35 ft., 12-conductor receiver cable, with quickdisconnect socket

QDX-12

12 ft., 3-conductor transmitter cable, with quickdisconnect socket

QDX-20

20 ft., 3-conductor transmitter cable, with quickdisconnect socket

QDX-100

100 ft., 3-conductor transmitter cable, with quickdisconnect socket

BS2LA

Laser Alignment Tool

Safety Standards and Precautions
The BeamSafe II meets applicable OSHA, ANSI and RIA
standards and was designed in accordance with IEC61496, DIN
EN 50100 and EN 954-1.
Only use the BeamSafe II on machinery that stops consistently
and immediately anywhere in its cycle or stroke. Never use a
BeamSafe II on a full-revolution clutched press or machine.
The BeamSafe II is a single optical beam, not a curtain of light.
Therefore it is not designed for use as a point-of-operation device.
If one or more BeamSafe II systems do not protect all access to
the hazardous machine area, the unprotected access must be
guarded by fencing, barriers or other appropriate methods.
The purchaser, installer and employer are responsible for
meeting all appropriate laws, rules and regulations relating to the
proper use, installation, operation and maintenance of this control
and the guarded machine.

information on safety light
✎ For
curtain accessories, see page D74

Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357	 Canada Tel. 1/866/986-6766	 www.sti.com

OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com

OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300

OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com

OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920

OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com

OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu

Authorized Distributor:

Automation Control Systems
• Machine Automation Controllers (MAC) • Programmable Controllers (PLC)
• Operator interfaces (HMI) • Distributed I/O • Software
Drives & Motion Controls
• Servo & AC Drives • Motion Controllers & Encoders
Temperature & Process Controllers
• Single and Multi-loop Controllers
Sensors & Vision
• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors
• Amplified Photomicrosensors • Measurement Sensors
• Ultrasonic Sensors • Vision Sensors
Industrial Components
• RFID/Code Readers • Relays • Pushbuttons & Indicators
• Limit and Basic Switches • Timers • Counters • Metering Devices
• Power Supplies
Safety
• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety
Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

F242I-E-01

07/15

Note: Specifications are subject to change.
Printed on recycled paper.

© 2015 Omron Electronics LLC

Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : Omron
Create Date                     : 2012:08:20 15:10:10-05:00
Keywords                        : BeamSafe II Perimeter Access Guarding Sensor, sti, light curtain
Modify Date                     : 2015:07:10 09:41:39-05:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Instance ID                     : uuid:8ad605b3-c876-4b27-9684-a139c21ccdd6
Original Document ID            : adobe:docid:indd:d4b18561-5753-11de-b0bf-a560c17a1bc9
Document ID                     : xmp.id:5CB0AB9D00246811822AC499020A12DA
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:5AB0AB9D00246811822AC499020A12DA
Derived From Document ID        : xmp.did:F38E8D96F6236811822AC499020A12DA
Derived From Original Document ID: adobe:docid:indd:d4b18561-5753-11de-b0bf-a560c17a1bc9
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2012:08:20 15:10:10-05:00
Metadata Date                   : 2015:07:10 09:41:39-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Title                           : BeamSafe II Perimeter Access Guarding Sensor Datasheet
Description                     : BeamSafe II Perimeter Access Guarding Sensor
Creator                         : Omron
Subject                         : BeamSafe II Perimeter Access Guarding Sensor, sti, light curtain
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 7
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu