Blood Gas Analyzer 2011
2015-05-08
: Pdf Blood-Gas-Analyzer 2011 blood-gas-analyzer_2011 11 2011 rtmagazi uploads wp-content
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
|| tech guide || Technology Guide Blood Gas Analyzers alere inc instrumentation laboratory Nova Biomedical epoc® GEM® Premier™ 4000 critical care analyzer Stat Profile® pHOx® Product Calibration/Measurement Web site www.alere.com www.ilus.com www.novabiomedical.com Sample volume 92 μL 65 μL micro mode, 100 μL CO-Ox/Total Bilirubin, 135 μL full menu 45 µL to 125 µL Calibration time ~170 seconds Automated continuous with iQM 3 to 5 minutes Measurement time ~35 seconds 70 seconds for electrochemical and 25 additional seconds for CO-Ox 45 to 52 seconds Analytes Measured: pH, Pco2, Po2, Hct, Na, K, iCa, Lactate, Glucose; Calculated: Hgb, O2SAT, BEb, BEecf, tco2, Hco3 Measured: pH, Pco2, Po2, Na+, K+, Cl-, iCa++, Glu, Lact, Hct, tHb, COHb, HHb, MetHb, O2Hb, Total Bilirubin; Calculated: Hct, tco2, BEecf (in vivo), BE(B) (in vivo), tHb(c), Ca++ (7.4), anion gap, P/F ratio, pao2, Cao2, Cvo2, P50, O2cap, sO2(c), Hco3- std, Hco33- (c), AaDO2, Pao2/Pao2, RI, CcO2, a-vDO2, Qsp/Qt(est), Qsp/Qt pH, Po2, Pco2, SO2%, Hct, Hb, Na+, K+, Cl, Ca, Glu, Lac Typical cycle time ~30 seconds 90 seconds Throughput of 40 to 50 samples per hour Operating temperature 15°C to 30°C (59°F to 86°F) 12°C to 32°C (53.6°F to 89.6°F) Ambient operating temperature is 15°C to 30°C (59°F to 86°F) Sample type Heparinized or un-anticoagulated arterial, venous, or capillary whole blood Whole blood, capillary, mixed venous, arterial, venous Whole blood, arterial, mixed venous, venous, capillary, serum/plasma Measurement principle pH, iCa, Pco2, Na, K: potentiometry; Po2, lactate, glucose: amperometry; Hct: conductometry Electrochemical, conductivity, CO-Ox Direct ISE, Severinghaus, Optical, Conductivity, Enzyme/Amperometric Sample application Injection Syringe, capillary, tube, ampoule Syringe, tube, capillary tube (no adapter required) Data storage Data Management System, Database and Web Server Security 100 MB (unlimited patient samples) All quality control data is automatically stored. Daily and cumulative statistical reports and Levey-Jennings graphs can be printed at any time. Password Yes Yes Multilevel password with unique user ID No. QC Lockout Yes User definable QC and new lot lockout options Yes Height x width x depth (inches) 3 x 3.4 x 8.5 18 x 12 x 15 15 × 12 × 15 Weight ~1.5 pounds 44 pounds 18 pounds Voltage/frequency Reader: AC input: 100-240 Vac, .5 amps, 50-60 Hz; DC output: 5 volts, 3 amps; Host: Input: 100-240 Vac, 50/60 Hz, 500 mA; Output: 5 Vdc, 3000 mA 100 VAC/3 Amps Voltage - /Freq - 50/60 Hz 90-264 VAC, 50/60 Hz Power consumption (max) DC output: 5 volts, 3 amps 300 VA 200 W Interface HL7 ASTM1394/HL7 RS232 serial communication and HL7 ASTM Standard data protocols, HL7 on TCP/IP, USB ports Approvals FDA 501(k) clearance on epoc System and all analytes represented CE, CSA, EMC Emissions and Immunity, European Union Directive 2002/96/EC on WEEE, CEI/IEC 61010.1, FDA ISO 13485; 2003, ISO 9001; 2000 Quality System, Registration, CSA, TüV, IVDD CE Self Declared, CSA, TüV. Complies to EN 61010, EN 50081,82 Security Dimensions/ Weight Miscellaneous Other Features 32 Room-temperature card storage (up to 6 months); bar-coded test cards for quality and inventory management; fully wireless data transfer to data manager, real time (no need to dock for download). RT | For Decision Makers in Respiratory Care RT11_32-33_TechGuideBloodGas.indd 32 iQM detects, corrects, and documents instrument errors, reducing error detection time to minutes; single component, multi-use PAK includes all testing components, is changed every 30 days, requires no refrigeration or maintenance; GEMweb Plus Custom Connectivity software allows access and control from any networked PC or GEM Premier 4000 analyzer. Onboard auto-cartridge QC; all-liquid calibration cartridge eliminates gas tanks; single reagent cartridge has all supplies for calibration and waste collection. November 2011 10/26/11 11:13:44 AM Technology Guide Blood Gas Analyzers Product Web site Calibration/Measurement siemens healthcare diagnostics inc Stat Profile® pHOx® ULTRA OPTI® CCA-TS analyzer RAPIDPoint® 500 system www.optimedical.com www.siemens.com/diagnostics Sample volume 60 µL to 210 µL 125 µL for most cassettes, 60 µL cassette available Max no. of patient samples per hour/max no. measured; results per hour 25/up to 325; sample size 100 μL minimum Calibration time 3 to 5 minutes ~1 minute 1 and 2 point (manual and automatic); 1 point: 30 minutes; 2 point: 2 hours Measurement time 1 to 2 minutes ~1.5 minutes ~60 seconds to result pH, Pco2, Po2, tHb, So2, Na+, K+, iCa, Cl-, glucose, lactate, and BUN (in various test configurations) pH, Pco2, Po2, Hb, Na+, K+, Cl-, iCa, glucose, neonatal total bilirubin, COOXimeter fractions (fO2Hb, fCOHb, fMetHb, fHHb) pH, Po2, Pco2, SO2%, Hct, Hb, Na, K, Cl, Ca, iMg, Glu, BUN, Creat, Lac, CO-Ox (HHb, O2Hb, COHb, MetHb, tBil) Typical cycle time Throughput up to 38 samples per hour ~2.5 minutes ~60 seconds Operating temperature Ambient operating temperature is 15°C to 30°C (59°F to 86°F) 10°C to 32°C (50°F to 90°F) 15°C to 32°C (59°F to 90°F) Sample type Whole blood, arterial, mixed venous, venous, capillary, serum/plasma Whole blood, serum, plasma Whole blood Measurement principle Direct ISE, Severinghaus, Amperometric, Optical, Conductivity, Enzyme/ Amperometric Optical fluorescence and reflectance pH, iCa, Na, Cl, K: potentiometry using ISE; Pco2: potentiometry based on Severinghaus; Po2: amperometric; glucose: amperometric, glucose oxidase; Hb: spectrophotometric Sample application Syringe, tube, capillary tube (no adapter required) Syringe or capillary by automatic aspiration Specimen types suitable for device: whole blood, capillary, mixed venous, arterial, venous, heparin/aspiration Onboard data management Holds 200 patient records and 1 month of QC on board. RAPIDComm Data Management system Password Multilevel password with unique user ID No. Password protected setup and operation, holds up to 300 secure operator IDs/PINs. Yes QC Lockout Yes User definable QC and new lot lockout options Yes Height x width x depth (inches) 17.2 × 22.4 × 17.3 5 x 14 x 9 21.5 × 11.5 × 16 Weight 53 pounds 12 pounds with rechargeable battery 36.5 pounds Voltage/frequency 90-264 VAC, 50/60 Hz 120 or 240 AC/50-60 Hz n/a Power consumption (max) 350 W 110 VA n/a Interface RS232 serial communication and HL7 ASTM Standard data protocols, HL7 on TCP/IP, USB ports Ethernet, serial (ASTM or ASCII) Ethernet and RS232 via the Siemens communication protocol LIS3 and serial RS232 option Approvals ISO 13485; 2003, ISO 9001; 2000 Quality System, Registration, CSA, TüV, IVDD CE Self Declared, CSA, TüV, Complies to EN 61010, EN 50081,82 CE, UL, IVDD FDA approved Large whole blood critical care menu (20 tests), BUN, ionized Mg available exclusively from Nova; onboard co-oximeter; onboard QC cartridge provides sufficient QC materials for 30-day auto QC analysis; allows user to program frequency and select report protocol. Single use measurement cassette with automatic sample aspiration; color touch screen interface; barcode scanner; heated measurement for cold environments. No maintenance, multi-use cartridge; fast time to patient results and sample to sample throughput; 28-day, onboard, automatic quality control cartridge. Data storage Security Miscellaneous OPTI Medical www.novabiomedical.com Analytes Dimensions/ Weight Nova Biomedical Other features November 2011 RT11_32-33_TechGuideBloodGas.indd 33 www.rtmagazine.com 33 10/26/11 11:13:50 AM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2011:11:04 13:32:20-04:00 Creator : Adobe InDesign CS3 (5.0) Modify Date : 2011:11:13 23:51:11-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2011:11:13 23:51:11-05:00 Creator Tool : Adobe InDesign CS3 (5.0) Format : application/pdf Document ID : uuid:c93e4014-ea59-4802-bc16-a143ffd90598 Instance ID : uuid:b8f24544-9a9f-461a-8fc3-486c7f62c7eb Producer : Adobe PDF Library 8.0 Page Count : 2EXIF Metadata provided by EXIF.tools