Communications Systems | LBB 1965/00 Plena Message Manager LBB 1965/00 Plena Message Manager ▶ Highly flexible stand‑alone digital message player ▶ Up to 12 messages and 12 trigger inputs ▶ Downloads messages from a PC in WAV format ▶ Compliant with standards for emergency sound systems ▶ Zone control for Plena system preamplifier LBB 1925/10 ▶ Front panel control and remote control The Plena message manager is a high performance, highly versatile stand-alone digital message player. Applications range from spot announcements in supermarkets and theme parks to warning and evacuation messages in emergency situations. Functions Messages Up to 12 messages can be stored in the internal 64Mbit EEPROM, without the need for data retention battery backup. Each message can have any length within the total available capacity. A PC uploads messages and configurations via RS-232 to the unit, which can then operate without a PC. The standard WAV format is used for messages with sample rates of 8 kHz to 24 kHz with 16-bit word length (linear PCM). This gives up to 500 seconds of recording time with a CD‑quality signal-tonoise ratio. The use of linear PCM instead of a compressed audio format, such as MP3, ADPCM and ulaw/A-law, ensures high-quality playback of all types of audio signals, including sound effects and special tones, such as attention chimes. The unit has 12 contact closure trigger inputs for announcements. Each can be configured for a sequence of up to four messages from those available. In this way messages can be used in combination with other messages, optimizing flexibility and storage space usage. When used together with the six-zone LBB 1925/10 Plena System Pre-Amplifier, a zone selection can be configured for each trigger input. The message manager communicates this selection to the LBB 1925/10 via an RS-232 connection. Continuous activation of a trigger input causes the corresponding message sequence to repeat. Trigger Inputs The trigger inputs have a serial priority, i.e., input 1 has priority over input 2, input 2 over input 3, etc. The high priority trigger inputs 1-6 are only accessible as contacts on the rear panel to prevent accidental use. The lower priority trigger inputs 7-12 are also available as trigger switches on the front panel. Integrity and Dependability The LBB 1965/00 can also play emergency/evacuation messages, as it fulfills the IEC 60849 standard. The microcontroller continually checks the data integrity of the system, and a watchdog circuit, in turn, checks the microcontroller. The unit monitors the D/A converter with a pilot tone, and the high priority trigger inputs (one to six) for cable short circuits and breaks. A 24 V battery www.boschsecurity.com 2 | LBB 1965/00 Plena Message Manager backup connection with automatic fail-safe provides continued operation if the mains power should fail. A 20 kHz pilot tone can be mixed with the output signal to supervise the link to the next amplifier. This also works for loudspeaker supervision in combination with 20 kHz detectors. Any failure causes a red LED fault indication, and activates a fault output contact. Parts Included Loop-through Facility The LBB 1965/00 provides a loop-through facility with balanced XLR and unbalanced cinch inputs and outputs. This allows the unit to be inserted into an existing audio link. As long as no announcements are playing, the signal input is routed to the output. If an announcement begins, the input signal is interrupted and the announcement is routed to the output. Updating Messages and configuration settings are uploaded from a PC. After uploading, the trigger inputs 7-12 can be configured by using the front panel switches, without the need for a new upload or even a PC. Message content can be monitored using the available headphone jack. Quantity Component 1 LBB 1965 Plena Message Manager 1 Power cord 1 Set of 19" mounting brackets 1 Plena CD 1 Installation and User Instructions Technical Specifications Electrical Mains power supply Voltage 230/115 VAC, ±10%, 50/60 Hz Inrush current 1.5 A at 230 VAC / 3 A at 115 VAC Max power consumption 50 VA Battery power supply Voltage 24 VDC, +15% / -15% Current max 1A Performance Certifications and Approvals Region Certification Europe CE Declaration of Conformity Safety according to EN 60065 Immunity according to EN 55103-2 Emission according to EN 55103-1 Installation/Configuration Notes LBB 1965/00 back view Supported sample rates (fs) 24 / 22.05 / 16 / 12 / 11.025 / 8 kHz Frequency response @ fs=24kHz @ fs=22.05kHz 100 Hz to 11 kHz (+1 / -3 dB) 100 Hz to 10 kHz (+1 / -3 dB ) @ fs=16kHz 100 Hz to 7.3 kHz (+1 / -3 dB ) @ fs=12kHz 100 Hz to 5.5 kHz (+1 / -3 dB) @ fs=11.025kHz 100 Hz to 5 kHz (+1 / -3 dB) @ fs=8kHz 100 Hz to 3.6 kHz (+1 / -3 dB) Distortion <0.1% at 1 kHz S/N (flat at max volume) >80 dB Supervision DAC 1 Hz pilot tone Line input 1x Connector 3-pin XLR, balanced Sensitivity 1V Impedance 20 kohm CMRR >25 dB (50 Hz-to 20 kHz) Line input 1x Connector Cinch, unbalanced Sensitivity 1V Impedance 20 kohm Trigger input 6x Connector Screw Activation Contact closure Supervision method Cable loop resistance check Line output 1x Connector 3-pin XLR, balanced Nominal level 1 V, adjustable LBB 1965/00 Plena Message Manager | 3 Mains power supply Impedance <100 ohm Line output 1x Connector Cinch, unbalanced Nominal level 1 V, adjustable Impedance <100 ohm Message active output 1x Connector Screw Relay 100 V, 2 A (voltage free, SPDT) Fault output 1x Connector Screw Relay 100 V, 2 A (voltage free, SPDT) Interconnection 1x Connector 9-pin D-sub (RS-232) PC protocol 115 kb/s, N, 8, 1, 0 (upload) LBB 1925/10 protocol 19.2 kb/s, N, 8, 1, 0 (zone control) Messages Data format WAV-file, 16-bit PCM, mono Memory capacity 64 Mb EEPROM Recording/playback time 500 s @ fs=8 kHz 167 s @ fs=24 kHz Number of messages 12 (maximum) Data retention time >10 years Mechanical Dimensions (H x W x D) 56 x 430 x 270 mm 2.20 x 16.92 x 10.62 inch (19" wide, 1U high, with feet) Weight Approx. 3 kg Mounting Stand‑alone, 19” rack Color Charcoal Environmental Operating temperature -10 ºC to +55 ºC (14 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity <95% Ordering Information LBB 1965/00 Plena Message Manager high performance, highly versatile standalone digital message player LBB1965/00 www.boschsecurity.com 4 | LBB 1965/00 Plena Message Manager Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems Inc. 2010 | Data subject to change without notice T866759563 | Cur: en-US, V22, 2 Dec 2010 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : Bosch Security Systems Create Date : 2010:12:02 12:14:55+01:00 Modify Date : 2010:12:02 12:14:55+01:00 Creator : AH Formatter V5.0 MR2a (5,0,2009,0623) for Windows Producer : Antenna House PDF Output Library 2.6.0 (Windows) Title : LBB 1965/00 Plena Message Manager Trapped : False Page Count : 4 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools