Communications Systems | LBB 1965/00 Plena Message Manager

LBB 1965/00 Plena Message Manager
▶ Highly flexible stand‑alone digital message player
▶ Up to 12 messages and 12 trigger inputs
▶ Downloads messages from a PC in WAV format
▶ Compliant with standards for emergency sound
systems
▶ Zone control for Plena system preamplifier
LBB 1925/10
▶ Front panel control and remote control

The Plena message manager is a high performance, highly
versatile stand-alone digital message player. Applications
range from spot announcements in supermarkets and
theme parks to warning and evacuation messages in
emergency situations.

Functions
Messages
Up to 12 messages can be stored in the internal 64Mbit
EEPROM, without the need for data retention battery
backup. Each message can have any length within the
total available capacity. A PC uploads messages and
configurations via RS-232 to the unit, which can then
operate without a PC. The standard WAV format is used
for messages with sample rates of 8 kHz to 24 kHz with
16-bit word length (linear PCM). This gives up to
500 seconds of recording time with a CD‑quality signal-tonoise ratio. The use of linear PCM instead of a
compressed audio format, such as MP3, ADPCM and ulaw/A-law, ensures high-quality playback of all types of
audio signals, including sound effects and special tones,
such as attention chimes.

The unit has 12 contact closure trigger inputs for
announcements. Each can be configured for a sequence of
up to four messages from those available. In this way
messages can be used in combination with other
messages, optimizing flexibility and storage space usage.
When used together with the six-zone LBB 1925/10 Plena
System Pre-Amplifier, a zone selection can be configured
for each trigger input. The message manager
communicates this selection to the LBB 1925/10 via an
RS-232 connection. Continuous activation of a trigger
input causes the corresponding message sequence to
repeat.
Trigger Inputs
The trigger inputs have a serial priority, i.e., input 1 has
priority over input 2, input 2 over input 3, etc. The high
priority trigger inputs 1-6 are only accessible as contacts
on the rear panel to prevent accidental use. The lower
priority trigger inputs 7-12 are also available as trigger
switches on the front panel.
Integrity and Dependability
The LBB 1965/00 can also play emergency/evacuation
messages, as it fulfills the IEC 60849 standard. The
microcontroller continually checks the data integrity of
the system, and a watchdog circuit, in turn, checks the
microcontroller. The unit monitors the D/A converter with
a pilot tone, and the high priority trigger inputs (one to
six) for cable short circuits and breaks. A 24 V battery

www.boschsecurity.com

2 | LBB 1965/00 Plena Message Manager

backup connection with automatic fail-safe provides
continued operation if the mains power should fail. A
20 kHz pilot tone can be mixed with the output signal to
supervise the link to the next amplifier. This also works for
loudspeaker supervision in combination with 20 kHz
detectors. Any failure causes a red LED fault indication,
and activates a fault output contact.

Parts Included

Loop-through Facility
The LBB 1965/00 provides a loop-through facility with
balanced XLR and unbalanced cinch inputs and outputs.
This allows the unit to be inserted into an existing audio
link. As long as no announcements are playing, the signal
input is routed to the output. If an announcement begins,
the input signal is interrupted and the announcement is
routed to the output.
Updating
Messages and configuration settings are uploaded from a
PC. After uploading, the trigger inputs 7-12 can be
configured by using the front panel switches, without the
need for a new upload or even a PC. Message content can
be monitored using the available headphone jack.

Quantity Component
1

LBB 1965 Plena Message Manager

1

Power cord

1

Set of 19" mounting brackets

1

Plena CD

1

Installation and User Instructions

Technical Specifications
Electrical
Mains power supply
Voltage

230/115 VAC, ±10%, 50/60 Hz

Inrush current

1.5 A at 230 VAC / 3 A at 115 VAC

Max power consumption

50 VA

Battery power supply
Voltage

24 VDC, +15% / -15%

Current max

1A

Performance

Certifications and Approvals
Region

Certification

Europe

CE

Declaration of Conformity

Safety

according to EN 60065

Immunity

according to EN 55103-2

Emission

according to EN 55103-1

Installation/Configuration Notes

LBB 1965/00 back view

Supported sample rates (fs)

24 / 22.05 / 16 / 12 / 11.025 / 8 kHz

Frequency response
@ fs=24kHz
@ fs=22.05kHz

100 Hz to 11 kHz (+1 / -3 dB)
100 Hz to 10 kHz (+1 / -3 dB )

@ fs=16kHz

100 Hz to 7.3 kHz (+1 / -3 dB )

@ fs=12kHz

100 Hz to 5.5 kHz (+1 / -3 dB)

@ fs=11.025kHz

100 Hz to 5 kHz (+1 / -3 dB)

@ fs=8kHz

100 Hz to 3.6 kHz (+1 / -3 dB)

Distortion

<0.1% at 1 kHz

S/N (flat at max volume)

>80 dB

Supervision DAC

1 Hz pilot tone

Line input

1x

Connector

3-pin XLR, balanced

Sensitivity

1V

Impedance

20 kohm

CMRR

>25 dB (50 Hz-to 20 kHz)

Line input

1x

Connector

Cinch, unbalanced

Sensitivity

1V

Impedance

20 kohm

Trigger input

6x

Connector

Screw

Activation

Contact closure

Supervision method

Cable loop resistance check

Line output

1x

Connector

3-pin XLR, balanced

Nominal level

1 V, adjustable

LBB 1965/00 Plena Message Manager | 3

Mains power supply
Impedance

<100 ohm

Line output

1x

Connector

Cinch, unbalanced

Nominal level

1 V, adjustable

Impedance

<100 ohm

Message active output

1x

Connector

Screw

Relay

100 V, 2 A (voltage free, SPDT)

Fault output

1x

Connector

Screw

Relay

100 V, 2 A (voltage free, SPDT)

Interconnection

1x

Connector

9-pin D-sub (RS-232)

PC protocol

115 kb/s, N, 8, 1, 0 (upload)

LBB 1925/10 protocol

19.2 kb/s, N, 8, 1, 0 (zone control)

Messages
Data format

WAV-file, 16-bit PCM, mono

Memory capacity

64 Mb EEPROM

Recording/playback time

500 s @ fs=8 kHz
167 s @ fs=24 kHz

Number of messages

12 (maximum)

Data retention time

>10 years

Mechanical
Dimensions (H x W x D)

56 x 430 x 270 mm
2.20 x 16.92 x 10.62 inch
(19" wide, 1U high, with feet)

Weight

Approx. 3 kg

Mounting

Stand‑alone, 19” rack

Color

Charcoal

Environmental
Operating temperature

-10 ºC to +55 ºC (14 ºF to +131 ºF)

Storage temperature

-40 ºC to +70 ºC (-40 ºF to +158 ºF)

Relative humidity

<95%

Ordering Information
LBB 1965/00 Plena Message Manager
high performance, highly versatile standalone digital message player

LBB1965/00

www.boschsecurity.com

4 | LBB 1965/00 Plena Message Manager

Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us

Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com

© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T866759563 | Cur: en-US, V22, 2 Dec 2010

Asia-Pacific:
Represented by
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6258 5511
Fax: +65 6571 2698
apr.securitysystems@bosch.com
www.boschsecurity.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Author                          : Bosch Security Systems
Create Date                     : 2010:12:02 12:14:55+01:00
Modify Date                     : 2010:12:02 12:14:55+01:00
Creator                         : AH Formatter V5.0 MR2a (5,0,2009,0623) for Windows
Producer                        : Antenna House PDF Output Library 2.6.0 (Windows)
Title                           : LBB 1965/00 Plena Message Manager
Trapped                         : False
Page Count                      : 4
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu