Robotiq Universal Controller Instruction Manual

Table of Contents
Table of Contents

2

Revisions

3

1. General Presentation

4

2. Safety

6

2.1 Warning

7

2.2 Intended Use

8

3. Installation
3.1 Scope of Delivery

9
9

3.2 Environmental and operating conditions

10

3.3 Mechanical connections

11

3.4 Power supply specifications

12

3.5 Wiring

13

3.5.1 Power connection

15

3.5.2 Communication connection

17

4. Control

26

4.1 Overview

26

4.2 Status LEDs

26

4.2.1 Supply LED

27

4.2.2 Communication LED

27

4.2.3 Fault LED

27

4.3 Controller register mapping

28

4.4 Robot output registers & functionalities

28

4.5 Robot input registers & status

29

5. User Interface

30

6. Specifications

31

6.1 Technical dimensions

31

6.2 Mechanical specifications

32

6.3 Moment of inertia and center of mass

32

6.4 Electrical ratings

33

7. Maintenance

34

8. Spare Parts, Kits and Accessories

35

9. Troubleshooting

36

10. Warranty

38

11. Contact

39

©Robotiq inc. 2008 - 2014

2

Robotiq Universal Controller Instruction Manual

Revisions
Robotiq may modify this product without notice, when necessary, due to product improvements, modifications or changes in specifications. If such modification is
made, the manual will also be revised, see revision information. See the latest version of this manual online at http://support.robotiq.com/.
Revision 180327
Udated section 3 : Installation
Revision 140626
Manual release
Copyright
© 2008-2014 Robotiq Inc. All rights reserved.
This manual, and the product it describes, are protected by the Copyright Act of Canada, by laws of other countries, and by international treaties, and therefore
may not be reproduced in whole or in part, whether for sale or not, without prior written consent from Robotiq. Under copyright law, copying includes translation
into another language or format.
Information provided by Robotiq in this document is believed to be accurate and reliable. However, no responsibility is assumed by Robotiq for its use. There may
be some differences between the manual and the product if the product has been modified after the edition date.
The information contained in this document is subject to change without notice.

©Robotiq inc. 2008 - 2014

3

Robotiq Universal Controller Instruction Manual

1. General Presentation
The terms "Controller", "Universal Controller", "Robotiq Controller" , "K-Model", and "Robotiq Universal Controller" used in the following manual all refer to the
Robotiq Universal Controller. The Robotiq Universal Controller is a robotic peripheral controller for other Robotiq devices and communication with other robot
controllers. The Universal Controller is designed for industrial applications with various communication protocols and is common to all Robotiq devices.

Note
The following manual uses the metric system, unless specified, all dimensions are in millimeters.

Note
The following section presents the key features of the Controller and must not be considered as related to Controller operation, each feature is detailed in
an appropriate section of the manual. Safety guidelines must be read and understood before any operation is attempted with the Controller.
The Universal Controller has two panels as shown in Figure 1.1. The front panel is called the Communication Panel and covers standard and optional
communication features. The side panel is called the Supply Panel and features the connector for supply of the Controller, setup of emergency stop and the
Robotiq Device Connector.

Figure 1.1 : The Robotiq Universal Controller.

©Robotiq inc. 2008 - 2014

4

Robotiq Universal Controller Instruction Manual

All Robotiq Universal Controllers have a standard USB 2.0 port available for serial communication. Optional communication panel choices are :
l

Ethernet family protocols
l
l
l
l

l
l
l

Ethernet / IP
Modbus TCP
EtherCAT
PROFINET

DeviceNet
CANopen
Profibus

The Supply Panel is standard on all Controllers and includes a supply connector with an emergency stop feature and the Robotiq Device Connector for connection
to the various Robotiq Grippers.
Info
See section 3.5.1 Power connection for details on the Supply Panel and section 3.5.2 Communication connection for details on the Communication Panel.
The Robotiq User Interface can be used via the standard USB 2.0 port to control or configure Robotiq devices. Visit http://support.robotiq.com to get the latest
installer of the Robotiq User Interface along with appropriate documentation.
See the Robotiq User Interface Instruction Manual for details on usage of the RUI.

©Robotiq inc. 2008 - 2014

5

Robotiq Universal Controller Instruction Manual

2. Safety
Warning
The operator must have read and understood all of the instructions in the following manual before handling the Robotiq Universal
Controller and the associated Gripper device.

The term "operator" refers to anyone responsible for any of the following operations on the Universal Controller and associated Gripper device :
l
l
l
l
l
l
l

Installation
Control
Maintenance
Inspection
Calibration
Programming
Decommissioning

This documentation explains the various components of the Universal Controller and its general operation. Read this documentation and the associated Robotiq
Gripper device documentation and be sure to understand its contents before handling the Controller or Gripper.
The drawings and photos in this documentation are representative examples and differences may exist between them and the delivered product.

©Robotiq inc. 2008 - 2014

6

Robotiq Universal Controller Instruction Manual

2.1 Warning
Note
Any use of the Controller in noncompliance of these warnings is inappropriate and may cause injury or damage.

Warning
Concerning Controller use in a robot environment (with robot and/or Robotiq Grippers):
l
l
l
l
l
l
l
l

Respect all robot safety recommendations.
Respect all Gripper safety recommendations.
Controller must be installed in a secured and clean environment.
Make sure all cord sets are always secured at the Gripper, the Controller and at the robot.
Respect power supplies according to the associated Robotiq device.
Respect fusing according to the associated Robotiq device.
Always respect the recommended keying for electrical connections.
Never supply the Gripper with an alternative current source.

Any usage of the Controller beyond these definitions is inappropriate and may cause injury or damage.

Note
Usage of the Universal Controller with an emergency stop is strongly recommended.

©Robotiq inc. 2008 - 2014

7

Robotiq Universal Controller Instruction Manual

2.2 Intended Use
The Controller unit is designed for control of Robotiq devices such as the Robotiq Adaptive Robot Gripper series.
Caution
The Controller is NOT intended for robot control.
The product is intended to be installed in parallel to a robot or other automated machinery or equipment.
Note
Always comply with local and/or national laws, regulations and directives on automation safety and general machine safety.
The unit may be used only within the range of its technical data. Any other use of the product is deemed improper and unintended use. Robotiq will not be liable for
any damages resulting from improper use.

©Robotiq inc. 2008 - 2014

8

Robotiq Universal Controller Instruction Manual

3. Installation
Warning
Be sure to read and understand the safety instructions related to the Universal Controller prior to installation.

Warning
Respect robot and Gripper safety measure and installation before operating or even turning on the power supply.

3.1 Scope of Delivery
Standard upon delivery :
l
l

Robotiq Universal Controller (UNI-CTR-001-XXXX)
Replace XXXX by one of the following communication options :
ENIP - Ethernet / IP
MTCP - Modbus TCP
ECAT - EtherCAT
DNET - DeviceNet
CANO - CANopen
PNET - PROFINET

l
l
l
l
l
l
l
l

Controller Supply Connector with emergency stop jumper (CONN-COMB-2059)
DIN rail #3 mounting clips

Note
The following are not included with the delivery of the Robotiq Universal Controller unless specified :
l
l
l

Cables.
Hardware required for any of the communication options, accessories, faceplates or fixtures.
Power supply unit, power supply wiring or fuse.

See Spare Parts, Kits and Accessories section for a list of available parts and cables.

©Robotiq inc. 2008 - 2014

9

Robotiq Universal Controller Instruction Manual

3.2 Environmental and operating conditions
The Controller is designed for industrial applications but requires clean conditions and is not water resistant. Always respect the conditions specified for storage and
operating environments:

SPECIFICATION

VALUE

Minimum storage/transit temperature

-22°F [-30°C]

Maximum storage/transit temperature

158°F [70°C]

Minimum operating temperature

32°F [0°C]

Maximum operating temperature

158°F [70°C]

Humidity (non-condensing)

20-80% RH

Vibration
Others

< 0.5G
l
l
l

Free from dust, soot or water
Free from corrosive gases, liquids or explosive gases
Free from powerful electromagnetic interference sources

Info
If environmental conditions present dust, dirt or water, additional protection of the Controller will be required.

©Robotiq inc. 2008 - 2014

10

Robotiq Universal Controller Instruction Manual

3.3 Mechanical connections
Robotiq Universal Controller is meant to be mounted on #3 DIN rails (standard on all Controllers).
Here are the steps to follow for the installation of the Controller (see Figure 3.3.1).
1. Secure the DIN rail.
2. Clip mounting adapters onto the rails.

Figure 3.3.1 : Attaching the Universal Controller using the DIN rails.

©Robotiq inc. 2008 - 2014

11

Robotiq Universal Controller Instruction Manual

3.4 Power supply specifications
The Controller needs to be supplied by a DC voltage source. This power supply is not included with the Controller. Required power supply will be chosen according
to the associated Robotiq device. The following table shows the specifications regarding the power supply required to operate the Controller and Gripper properly.

POWER SUPPLY SPECIFICATION FOR VARIOUS ROBOTIQ DEVICES
SPECIFICATION

2-FINGER-85 (LASTEST)

VALUES FOR 2-FINGER-85 (LEGACY) AND 3FINGER GRIPPER

Output voltage

24 V DC

24 V DC

Output current

1A

2A

2-3 % peak-peak

2-3 % peak-peak

10% maximum

10% maximum

Recommended power supply as an internal
protection, otherwise fusing is required with :
2 A fuse at 77°F [25°C]2

Recommended power supply as an internal
protection, otherwise fusing is required with :
2 A fuse at 77°F [25°C]2

Not required1

Not required1

Ripple
Output regulation
Overcurrent

Overvoltage protection

Warning
1Always respect the ripple and output regulation tolerances on the output voltage, exceeding these limits could damage the Gripper. If your power supply

could exceed the specified regulation, over-voltage protection is required.

Info
2Suggested fuse is Phoenix Contact # 0916605 2 A thermal, use AWG #20 wiring.

Robotiq recommends the use of the following power supply:
l

For 4A : TDK-Lambda DPP Series, 100W Single Output DIN Rail Mount Power Supply, DDP100-24-1

©Robotiq inc. 2008 - 2014

12

Robotiq Universal Controller Instruction Manual

3.5 Wiring
The Controller communication ports are shown in Figure 3.5.1 and supply port in Figure 3.5.2. The Universal Controller is supplied via the Supply Connector port,
an optional emergency stop feature is present see section 3.5.1 Power connection for details on the supply pinout and emergency stop. Communication is
established with either the standard USB 2.0 port (for testing and configuration of the Controller) or via the optional communication fieldbus port, see section 3.5.2
Communication connection for details. The Robotiq devices are connected to the Controller via a single Gripper signal cable which connects onto the Robotiq
device port, the cable must be chosen according to the associated device, see the various Robotiq device manuals for details at support.robotiq.com.

Info
Note that the Communication Option Panel shown in Figure 3.5.1 will change according to the provided communication protocol. The Standard Panel,
which include the Status LEDs and the USB 2.0 port is standard on every Robotiq Universal Controller unit. The schematics bellow are represented with the
Ethernet family option.

Figure 3.5.1 : The Robotiq Universal Controller Communication Panel.

©Robotiq inc. 2008 - 2014

13

Robotiq Universal Controller Instruction Manual

Figure 3.5.2 : Controller Supply Connector and Robotiq Device Connector for the Robotiq Universal Controller.

Info
Device (Gripper) signal cable is supplied by Robotiq, see your Robotiq Gripper Spare Parts, Kits and Accessories section.

Warning
Use proper cabling management. Be sure to have enough forgiveness in the cabling to allow movement of the Robotiq device along all axes without pulling
out the connectors. Always protect the controller-side of the cable with a strain relief cable clamp.

©Robotiq inc. 2008 - 2014

14

Robotiq Universal Controller Instruction Manual

3.5.1 Power connection
Figure 3.5.1.1 presents the general cabling schematics of the Robotiq Universal Controller showing the power supply, fusing, grounding, emergency stop and
optional Robotiq device.

Note
Robotiq strongly advices the use of an emergency stop for all Robotiq devices. The emergency stop is normally closed. If an emergency stop is not used, a
jumper must be placed on pins 4 & 5 of the Supply Connector to allow usage of the device.

Caution
The fuse is external to the Controller and Robotiq device. It is not provided by Robotiq and the user is responsible for proper installation.

Info
Fusing must be chosen according to your Robotiq device, see details in section 3.4 Power supply specifications.

Figure 3.5.1.1 : Power connection diagram of the Robotiq Universal Controller.

The pin-out of the Supply Connector and the Robotiq Device Connector, as well as the matching device pinout are detailed in Figure 3.5.1.2.
Note
The 2-Finger 85 Gripper pin-out shows both generation of the Gripper, legacy Gripper has 8 pins while the lastest generation of the Gripper has 5 pins.

©Robotiq inc. 2008 - 2014

15

Robotiq Universal Controller Instruction Manual

Figure 3.5.1.2 : Universal Controller Supply Connector and Robotiq Device Connector with matching pinout.

Supply cable should have the following specifications :
l

For 2A supply (3-Finger Gripper and 2-Finger-85(legacy and latest))
l

minimum #22 AWG TEW, 300 V or 600 V.

The emergency stop cable should have the following specifications :
l
l
l

Minimum 22 AWG TEW (recommended, current is 500 mA), 300 V or 600V.
Using a "normally closed" emergency stop button.
Installed in compliance with the Machinery Directive or compliance to national standards derived from the directive used in your country.

Earth grounding cable should have the following specifications :
l

Same as supply.

Gripper signal cable is supplied by Robotiq, see the appropriate Spare Parts, Kits and Accessories section in your Robotiq device manual.

©Robotiq inc. 2008 - 2014

16

Robotiq Universal Controller Instruction Manual

3.5.2 Communication connection
The following table summarizes the communication protocols available for the Controller. A USB connection is standard on all Controllers, while the optional
communication panel will be setup for your options with a single communication protocol. See the following subsection for details on the communication parameters
of each communication option.

Note
Only one protocol option is available for a given Controller unit.

Family
Real-Time ethernet

Protocol
l
l
l
l

Fieldbus

l
l
l

USB

Ethernet / IP
Modbus TCP/IP
EtherCAT
ProfiNET
DeviceNET
CANopen
ProfiBUS

Modbus RTU

The Figure 3.5.2.1 shows the Communication Panel of the Robotiq Universal Controller. The communication port will vary depending on the communication
protocol chosen. Real-Time Ethernet family protocols ( Ethernet IP, EtherCAT, Modbus TCP) will come with two (2) RJ45 standard ports. DeviceNet protocol will
come with a 5-pin Combicon connector, CANopen with a standard male DB-9 connector, finally ProfiBUS will come with a standard female DB-9 connector.

Figure 3.5.2.1 : Representation of the Communication Panel options for the Robotiq Universal Controller.

©Robotiq inc. 2008 - 2014

17

Robotiq Universal Controller Instruction Manual

It is the users responsibility to setup the appropriate cable between the Controller unit and the master controller. Robotiq can provide you with appropriate cables
available on demand from its Spare Parts, Kits and Accessories section.

Warning
Be sure to use the appropriate cables and pinouts for your communication protocol as any other setup may damage the Controller.

©Robotiq inc. 2008 - 2014

18

Robotiq Universal Controller Instruction Manual

Real-time Ethernet communication protocols
Real-time Ethernet communication includes Ethernet/IP, EtherCAT, ProfiNET and Modbus TCP/IP protocols.
Factory settings for each Ethernet protocol:
IDENTIFICATION SETTINGS
EtherCAT

Ethernet/IP

ProfiNET

Modbus
TCP/IP

Vendor ID

0x0000FFFF

Vendor ID

0x0000011B

Vendor ID

0x0000011E

Product Code

0x0000000B

Product Code

0x0000010D

Device ID

0x0000010A

Serial Number

0x00000000

Product Type

0x0000000C

Device Type

Revision Number

0x00000000

Major Revision

1

Order ID

Minor Revision

1

Name of station

nic50repns

Device Name

AG-EIS

Type of station

Default.Station.Type

N/A

1541.110

Device Access Point

1

IDENTIFICATION SETTINGS
EtherCAT
N / A (see info note)

Ethernet/IP
IP Address

192.168.1.11

Bus Startup

Netmask

255.255.255.0

Watchdog Time

Gateway

Modbus TCP/IP
IP Address

192.168.1.11

Netmask

255.255.255.0

Disabled

Gateway

Disabled

BootP

Disabled

BootP

Disabled

DHCP

Disabled

DHCP

Disabled

100Mbit

Enabled

Full Duplex

Enabled

Auto-neg

Enabled

Assembly Instance (input)

101

Assembly Instance (output)

100

Configuration Instance
Connection Type

©Robotiq inc. 2008 - 2014

ProfiNET
Automatic
1000ms

1
Run/Idle Header

19

Robotiq Universal Controller Instruction Manual

IDENTIFICATION SETTINGS
EtherCAT

Ethernet/IP

ProfiNET

Input Data Bytes

16

Prod. Data Length

20

Output Data Bytes (16)

Output Data Bytes

16

Cons. Data Length

20

Module

Modbus
TCP/IP
N/A
1

Type

Byte

Count

16

N/A

Input Data Bytes (16)
Module

5

Type

Byte

Count

16

Info
EtherCAT protocol uses inherent dynamic addressing, thus bus settings cannot be customized.

Info
Ethernet/IP uses 4 bytes of header which may be visible or not depending on the master.

©Robotiq inc. 2008 - 2014

20

Robotiq Universal Controller Instruction Manual

DeviceNet communication protocol
The DeviceNet communication and the Controller use a 24 V power supply. Robotiq suggests to separate power supplies as shown in Figure 3.5.2.2.
Caution
l
l
l

There is no terminating resistor mounted in the Gripper.
The shield of the cable must be grounded in the robot controller.
Fusing must be respected.

Tip
DeviceNet standard requires a 120 Ohms resistor to be mounted at the beginning and at the end of the line. If the Gripper is the end of line, then a 120
Ohms resistor must be mounted between pin 2 and 4.

Figure 3.5.2.2 : Power connection diagram for the 3-Finger Gripper using DeviceNet Fieldbus.

©Robotiq inc. 2008 - 2014

21

Robotiq Universal Controller Instruction Manual

Factory settings for DeviceNet protocol:

Identification Settings
Info

Decimal Value (base 10)

Hexadecimal Value (base 16)

Vendor ID

283

0x0000011B

Product Code

35

0x00000023

Serial Number

0

0x00000000

Product Type

12

0x0000000C

Major Revision

1

Minor Revision

1

Product Name

AG-DNS

BUS SETTINGS
MAC ID

11

Baud Rate

250 KBaud

DATA SETTINGS

©Robotiq inc. 2008 - 2014

Prod. Data Length

16

Cons. Data Length

16

22

Robotiq Universal Controller Instruction Manual

CANopen communication protocol
Caution
l
l
l

There is no terminating resistor mounted in the Gripper.
The shield of the cable must be grounded in the robot controller.
Fusing must be respected.

Tip
CANopen standard requires a 120 Ohms resistor to be mounted at the beginning and at the end of the line. If Gripper is the end of line, then a 120 Ohms
resistor must but mounted between pin 4 and 5.

Figure 3.5.2.3 : Power connection diagram for the 3-Finger Gripper using CANopen Fieldbus.

©Robotiq inc. 2008 - 2014

23

Robotiq Universal Controller Instruction Manual

Identification Settings
Info

Decimal Value (base 10)

Hexadecimal Value (base 16)

Vendor ID

68

0x00000044

Product Code

1541540

0x001785A4

Revision Number

131072

0x00020000

Serial Number

0

0x00000000

BUS SETTINGS
MAC ID

11

Baud Rate

1 MBaud

DATA SETTINGS
Index

Size

Send Object

0x2000

128

Receive Object

0x2200

128

Output Databytes

512

Input Databytes

512

Hint
The CANopen communication interface supports SDO (Service Data Object) and PDO (Process Data Object) protocols.

©Robotiq inc. 2008 - 2014

24

Robotiq Universal Controller Instruction Manual

PROFIBUS communication protocol
PROFIBUS DP (Decentralized Peripheral) is an available option for the Robotiq Universal Controller.
Factory settings for PROFIBUS protocol:

IDENTIFICATION SETTINGS
Model Name

NIC 50-DPS

Identification Number

0x0C10

Station Address1

2

1Station address, the address of the device can be set anywhere between 0 and 126.

BUS SETTINGS
Bus startup

Automatic

Watchdog Time

1000 ms

Baud rate

Auto-detect

Sync supported

Enable

DATA SETTINGS
Output
Module

1

Size

16 Bytes

Size

16 Bytes

Input
Module

©Robotiq inc. 2008 - 2014

5

25

Robotiq Universal Controller Instruction Manual

4. Control
Info
Unless specified, all values in section 4 are hexadecimal values.

Info
Register format is Little Endian (Intel format), namely from LSB (Less Significant Bit) to MSB (Most Significant Bit). Meaning that bytes are written with the
least significant byte in the smallest address. If Big-endian it would be writing from left to right, Little-endian would be writing from right to left.

4.1 Overview
The Robotiq Universal Controller is accessed from the robot controller using an industrial protocol (Ethernet/IP, DeviceNet, CANopen, EtherCAT, etc.) and used
to operate a Robotiq device. The programming of the Robotiq device can be done with the Teach Pendant of the robot or by offline programming. To have more
information on your Robotiq device controls see the appropriate section in your device manual at support.robotiq.com.
Info
When accessing the Universal Controller with no Robotiq devices, no command can be sent and only fault status can be read. See the input registers &
status section for details.

4.2 Status LEDs
Four LED lights provide general information about the Controller and associated device status on the Controller Communication Panel. Figure 4.4.1 shows the
LEDs and their locations.

Figure 4.4.1 : Controller status LEDs.
There is an additional LED on the Robotiq device, see device manual for details.

©Robotiq inc. 2008 - 2014

26

Robotiq Universal Controller Instruction Manual

4.2.1 Supply LED
The following applies to the power LED on the Controller.
Color

State

Information

--

Off

No power supplied

Blue

On

Correctly supplied and the control board is
running (for the control board LED)

Color

State

Information

--

Off

No network detected

Green

Blinking

A network has been detected, but no connection
has been established

Green

On

A network has been detected and at least one
connection is established

4.2.2 Communication LED
The following applies to the communication LED on the Controller.

4.2.3 Fault LED
The following applies to the fault LED on the Controller.
Hint
Error code can be obtained reading the Fault Status byte described in section 4.5 Robot Input registers & status or using the Robotiq User Interface menu
option ''Input Registers".
For the Controller fault LED:
Color

State

Code

Information

--

Off

0x00

No fault detected
Warning

Red

0x04

24V not detected (reconfiguration through USB is possible)

0x05

No device detected

On

Minor fault occurred
0x09

Red

Blinking

©Robotiq inc. 2008 - 2014

The main communication protocol is ready (may be booting)
Major fault occurred

0x0C

Emergency stop triggered

0x0E

Overcurrent protection triggered (controller)

27

Robotiq Universal Controller Instruction Manual

4.3 Controller register mapping
For details on Robot Output / Functionalities see your Robotiq device instruction manual.
Info
Register format is Little Endian (Intel format), namely from LSB (Less Significant Bit) to MSB (Most Significant Bit).
Register mapping:
Caution
Byte numeration starts at zero and not at 1 for the functionalities and status registers.
Only Byte 2 of Robot Input / Status can be read when no Robotiq devices are present, if one is present, consult the appropriate instruction manual.
Register

Robot Input / Status

Byte 2

FAULT STATUS

4.4 Robot output registers & functionalities
See your Robotiq device instruction manual.

©Robotiq inc. 2008 - 2014

28

Robotiq Universal Controller Instruction Manual

4.5 Robot input registers & status
Info
Register format is Little Endian (Intel format), namely from LSB (Less Significant Bit) to MSB (Most Significant Bit).
Register: FAULT STATUS
Address: Byte 2
Bit

Name

Description

0 -- 3

gFLT

See Robotiq device instruction manual

4 -- 7

kFLT

0x00 – No Fault
Warning
0x04 – 24V not detected (reconfiguration through USB is possible)
0x05 – No device detected
Minor Fault (red LED continuous )
0x09 - Communication is not ready
Major Fault (red LED blinking) – Reset is required
0x0C – Emergency stop triggered
0x0E – Overcurrent protection triggered (Gripper)

©Robotiq inc. 2008 - 2014

29

Robotiq Universal Controller Instruction Manual

5. User Interface
Visit http://support.robotiq.com to get the latest installer for the Robotiq User Interface along with appropriate documentation.
See the Robotiq User Interface Instruction Manual for details on usage of the RUI.

©Robotiq inc. 2008 - 2014

30

Robotiq Universal Controller Instruction Manual

6. Specifications
6.1 Technical dimensions
Figure 6.1.1 presents the main technical dimensions of the Robotiq Universal Controller, axis system shown in red represents the coordinate system used to
calculate the center of mass and intertia values available in the follow sections.

Figure 6.1.1 : Robotiq Universal Controller technical dimensions shown with Ethernet family option.

©Robotiq inc. 2008 - 2014

31

Robotiq Universal Controller Instruction Manual

6.2 Mechanical specifications
Specification

Imperial units

Metric units

Controller Approximate Weight

1 lb

[0.475 kg]

Volume

12 in3

[200 cm3]

6.3 Moment of inertia and center of mass
The coordinate system used for calculating the moment of inertia and center of mass for the Controller is shown in Figure 6.3.1. The center of mass and moment of
inertia are calculated for a configuration with an Ethernet family option and may vary slightly for other options.
Info
All values are approximate.

Figure 6.3.1 : Approximate value for the moment of inertia and the center of mass for the Universal Controller.

©Robotiq inc. 2008 - 2014

32

Robotiq Universal Controller Instruction Manual

6.4 Electrical ratings
Below are the Electrical ratings for the Robotiq Universal Controller.
SPECIFICATION

VALUE

Operating Supply Voltage

24V

Absolute Maximum Supply Voltage

28V

Quiescent Power (minimum power consumption)

3.6W

Peak Power

See your Robotiq device instruction manual

Maximum RMS Supply Current (supply voltage at 24V)

12 A

Emergency stop entry current

50 mA

Emergency stop voltage

24V

©Robotiq inc. 2008 - 2014

33

Robotiq Universal Controller Instruction Manual

7. Maintenance
No maintenance is required on the Universal Controller.

Note
Controller must be kept away from dirty, dust, scraps, chemicals, etc.
Always respect the operating conditions.

Tip
It is a good practice to test emergency stop functionnality when doing Robotiq device maintenance.

©Robotiq inc. 2008 - 2014

34

Robotiq Universal Controller Instruction Manual

8. Spare Parts, Kits and Accessories
Spare parts, kits and accessories list :
The following list is up to date at print time and is subject to change, check online for updates.

Item

Description

Ordering Number

Standard Universal Controller

External Controller for Robotiq devices, includes Supply Connector with emergency
stop jumper.
Replace XXXX by one of the following communication protocol option :

UNI-CTR-001-XXXX

l
l
l
l
l
l
l

ENIP - Ethernet IP
MTCP - Modbus TCP/IP
ECAT - EtherCAT
DNET - Device Net
CANO - CANopen
PNET - ProfiNET
DPS - ProfiBUS

USB cable

5 m USB 2.0 cable, USB A - A male.
Meant for configuration of the Robotiq Universal Controller communication parameters
and control of Robotiq devices via the Robotiq User Interface.

Fieldbus cable

Available on demand

©Robotiq inc. 2008 - 2014

CBL-USB-2057

35

Robotiq Universal Controller Instruction Manual

9. Troubleshooting
If your Controller is not working, check the following:
1. Check the blue LED on the Controller:
a. It's ON : Check communication (step 2)
b. It's OFF : Controller not supplied, check power supply cable integrity and check power supply (see specification in section 3.4)
2. Check the green LED on the Controller:
a. It's OFF : No network detected, check communication cables and network infrastructure (see specific protocol in section 3.5.2 and step 4 below).
b. It's BLINKING : Network detected, no communication established, go to step 4.

Ethernet family protocol must be connected via RJ45 while CanOpen, DeviceNet and ProfiBUS must be connected via their own connectors.
c. It's ON : Network detected and communication is established, go to step 3.
3. Check the red LED on the Controller:
a. It's OFF : No fault, go to step 5.
b. It's BLINKING : Major fault occurred, reset (activate) the Controller (see section 4.5 for details on fault).
c. It's ON : Communication is not ready, wait until it's off, if blinking, reset is needed.
4. Communication & Networking issues:
a. Only use one connection at a time, either USB or the industrial protocol.
b. Ethernet family : Use the proper Ethernet options, Modbus TCP/IP and Ethernet IP require fixed IP, EtherCAT requires DHCP.
c. DeviceNet:
i. Requires a separate power supply (see DeviceNet section).
ii. May require a 120 Ohms terminating resistor.
d. CANopen:
i. Does not requires a separate power supply.
ii. May require a 120 Ohms terminating resistor.
e. After reprogramming communication options, wait until the red LED stops blinking to update the configuration.

Master communication device must use the same protocol and the same option settings as the Controller for the Gripper.
5. Other problems:
a. If the system shuts down (blue LED goes off) when the Robotiq device activates or grasps an object, check the power supply, the power supply must
meet the requirement of your Robotiq device.

©Robotiq inc. 2008 - 2014

36

Robotiq Universal Controller Instruction Manual

Possible troubleshooting issues:
1. Controller shuts down or does not power up.
2. Cannot establish a connection (Ethernet family).
3. Cannot establish a connection (CANbus family).

Q: Controller and/or associated Robotiq device shuts down when working or does not power up when connected.

A: Check the power supply specifications in section 3.3. Your power supply must meet the minimum requirements (according to the associated Robotiq device) and
the maximum operational voltage must not exceed 26 V.

Q: Cannot establish a connection under Ethernet / IP or Modbus TCP/IP.

A: Default settings for Ethernet / IP and Modbus TCP/IP use fixed addresses, you must:
1. Check device address using the Robotiq User Interface via USB. Communication protocol panel will show current address, default IP address for Robotiq
devices are IP 192.168.1.11 with Gateway 255.255.255.0.
2. Use the same protocol options (fixed IP, auto-neg, full duplex, etc.) shown in the Communication protocol panel. Set your Ethernet network card to use fixed
addresses other than the device address.
3. Set your master Ethernet network card to use fixed addresses other than the device address (for example use 192.168.1.10 if device address is
192.168.1.11).

Q: Cannot establish a connection under DeviceNet or CANopen.

A: Both protocols will use the CANbus, but make sure that DeviceNet is supplied with the adequate 24v power supply as specified in the DeviceNet communication
protocol. Both protocols will use default address node 11. CANopen default baud rate is set to 1 Mbaud while DeviceNet is set to 250 kBaud.

©Robotiq inc. 2008 - 2014

37

Robotiq Universal Controller Instruction Manual

10. Warranty
Robotiq warrants the Unviersal Controller against defects in material and workmanship for a period of one year from the date of reception when utilized as
intended with the specified maintenance. Robotiq also warrants that this equipment will meet applicable specifications under normal use.
Warranty applies under the following conditions:
l
l
l

Usage respects the operating and storage conditions specified in section 3.2
Usage under normal one-shift operation (40h a week)
Usage respect maintenance specified in section 7.

During the warranty period, Robotiq will repair or replace any defective product, as well as verify and adjust the product free of charge if the equipment should need
to be repaired or if the original adjustment is erroneous. If the equipment is sent back for verification during the warranty period and found to meet all published
specifications, Robotiq will charge standard verification fees.
The unit is considered defective when at least one of the following conditions occurs:
l
l
l

The Controller standard USB communication is not accessible;
The Controller optional communication is not accessible;
The Robotiq device feedback necessary for the robot program is not accessible.

Caution
The warranty will become null and void if the:
l
l
l
l
l
l

Unit has been tampered with, repaired or worked on by unauthorized individuals.
Warranty sticker has been removed.
Screws, other than as explained in this guide, have been removed.
Unit has been opened other than as explained in this guide.
Unit serial number has been altered, erased, or removed.
Unit has been misused, neglected, or damaged by accident.

This warranty is in lieu of all other warranties expressed, implied, or statutory, including, but not limited to, the implied warranties of merchantability and fitness for a
particular purpose. In no event shall Robotiq be liable for special, incidental, or consequential damages.
Robotiq shall not be liable for damages resulting from the use of the product, nor shall Robotiq be responsible for any failure in the performance of other items to
which the product is connected or the operation of any system of which the product may be a part.

Exclusion
Robotiq reserves the right to make changes in the design or construction of any of its products at any time without incurring obligation to make any changes
whatsoever on units already purchased.
This warranty excludes failure resulting from: improper use or installation, normal wear and tear, accident, abuse, neglect, fire, water, lightning or other acts of
nature, causes external to the product or other factors beyond Robotiq's control.

©Robotiq inc. 2008 - 2014

38

Robotiq Universal Controller Instruction Manual

11. Contact
www.robotiq.com
Contact Us

Phone
1-888-ROBOTIQ (762-6847)
(01) 418-380-2788 Outside US and Canada

Fax
1-418-800-0046

Technical support and Engineering
extension 207

Sales US
extension 122

Head office
Robotiq:
966, chemin Olivier
Suite 325
St-Nicolas, Québec
G7A 2N1
Canada

Where automation Pros come to share their know-how and get answers.
dof.robotiq.com

©Robotiq inc. 2008 - 2014

39



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 39
Page Mode                       : UseOutlines
Language                        : en-us
Producer                        : madbuild
Create Date                     : 2018:04:05 11:17:11-04:00
Modify Date                     : 2018:04:05 11:17:11-04:00
Title                           : Robotiq Universal Controller Instruction Manual
Author                          : phileon
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu