Cv Solid

2014-03-21

: Pdf Cv Solid cv_solid spec products alera

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadCv Solid
Open PDF In BrowserView PDF
CÛrv solid
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution

CHIT

SORS

AR

TURAL S

Project Name

Type

Catalog No.

Date

EN

E

Project Information
C

Construction

—Housing provides indirect distribution of light
—Up to four T8 lamps and up to three T5 or T5HO lamps
—The exact shape of the housing is maintained by the
use of an inner die cast plate at each fixture end.

Features

•	 2½" deep housing for a sleek modern appearance
•	 Indirect Luminaire
•	 Unique lamp crossing technique on one and three
lamp models maintains 48" modularity
•	 Heavy 20-gauge steel construction provides
excellent housing rigidity
•	 Controls compatible
•	 Available with optional installed open or closed
loop daylight sensors (DSPL, DSL) when daylight
dimming systems are desired
•	 Solid housing for 100% uplight
•	 Unique die cast aluminum, tongue and groove
couplers provide zero tolerance alignment resulting
in consistently straight rows
•	 Patented die cast aluminum end caps for a soft
finished appearance (Patent# 6,796,676B2)
•	 Flat end caps standard
•	 Modular mounting points for convenient hanging
locations
•	 Available with exclusive wiHUBB technology
preinstalled (WIH option)
– Peer to peer, self-healing wireless mesh 		
	network
– Integrated control system for 0-10VDC or 	 	
	 step dimming, or On/Off

Shape and Dimensions

—The housing is designed to wrap around the end
plates and secures on top with concealed screws to
ensure housing tolerances are consistent. These die
cast aluminum end caps and aligners provide zero
tolerance alignment between fixtures, resulting in
consistently straight rows with no snaking.
—Reflectors: standard with a painted white steel
reflector with specular inserts on the side.
—High efficiency reflector (HRF) high reflectance
specular material allows for wide distribution with
maximum efficiency.
—WR: An economical painted white reflector

Finish

The housing and all painted parts are treated with a
multi-stage phosphate bonding process before being
finished. Parts are then finished with a white RAL
powder coat finish for maximum consistent coverage
and longevity.

Mounting

—Aircraft cable suspension mechanism.
—Fixed cable has a total vertical adjustment
of 1¼".
End of cable barrel screws into a standard ¼-20
bolt brought down from the ceiling. A feed canopy
is provided for each feed location. All fixtures are
suspended in modular increments and must be
supported at each fixture-housing end.

2½"
9½"

—

—All luminaires are built to UL1598 Standards and bear
appropriate UL and cUL or CSA labels. Damp location
labeling is standard.
— Quick-connect plugs standard.

controls compatibility

Controls compatible. When used with Occupancy
Sensors, most lamp vendors recommend Program
Start ballast (EP) to extend lamp life. Common control
schemes: wiHUBB Enabled (WIH) switching (L/R or
IBOB), 0-10V dimming ballast (ED), Step Dimming
ballast (ESD), wiHUBB Enabled (WIH). Compatibility
with specific control (example, dimmer switch) is by
others. wiHUBB antenna will be visible. For daylight
sensors installed, see information below.

architectural sensors installed
Daylight sensors are used to measure available sunlight
and reduce electric light for energy savings. Alera
sensors are installed to be both accessible and visible
below the housing.
DSPL: Philips Luxsense, Mark 7 0-10V dimming ballast.
Closed loop sensor measures reflected light in a cone
below the sensor. Pre-commissioned by Philips to 45fc
standard; modest manual adjustability via sensor ring.
DSL: Lutron EcoSystem, digital dimming ballast.
Open loop sensor must be pointed directly at the
source of natural light. System requires proprietary
commissioning by others.
Additional technical data: see TID sheets, Alera website
and sensor manufacturer websites.

Name:
Test #:
Efficiency:
LER:

CV-1T8-S-E-WR
12991
97.2%
86

Example: CV-8-2T8-S-CM48-EU-MW

Ordering Information

CV —

Labels and Electrical

— S —

—

—

—

Adjustable
Voltage
Finish
MOUNTING Method
Cable length
U 120V-277V
MW Matte White (Std.)
FCM18 Fixed Aircraft
Cable Mount
48 48"
120 120V
ZT ZET Metallic Silver
(Non-adjustable,
277 277V
96 96"
See
Color Selection Guide
Std.) 18"
for other colors.
347 347V
Other lengths
CM Adjustable
available on
Options
Aircraft Cable
request.
Row length
LAMP TYPE AND PROFILE
Mount
WR White Reflector
4 4' Single
1T5 One T5 Lamp
HRF High Efficiency Reflector
Ballast
DC Dust Cover (N/A T5HO)5
8 8' Single
2T5 Two T5 Lamps
SCE Sculpted End Cap (55⁄16")5
E Electronic, Instant Start (Std. for T8)
12 12' Single
3T5 Three T5 Lamps
BN Bull Nose End Cap (51⁄16")5
EP Electronic, Programmed Start (Std. for T5
— Indicate row length
1T5HO One T5HO Lamp
LR Left/Right Switching (2-Lamp only)
&
T5HO,
optional
for
T8)
over 12' in 4'
2T5HO Two T5HO Lamps
IBOB Inboard/Outboard Switching (3-Lamp only)
increments
ELW Electronic T8, Low Wattage, Instant Start
3T5HO Three T5HO Lamps
F0841 With T8 4100L Lamp Installed
Note: Rows over 12' will
EPLW Electronic T8, Low Wattage, Programmed F5841 With T5(HO) 4100K Lamp Installed
2T8 Two T8 Lamps
be configured by Alera.
Start
F0835 With T8 3500K Lamp Installed
3T8 Three T8 Lamps
Example: 16' will be (2) 8'.
ED Electronic, Dimming (Must specify)
F5835 With T5(HO) 3500K Lamp Installed
Alternate configurations:
4T8 Four T8 Lamps
ESD Electronic, Step Dimming
EL One Emergency Battery Pack1, 2
contact factory.
EMC One Emergency Circuit 2, 3
EDUMK7
Universal
Voltage,
Electronic
Dimming
1
	Specify voltage. For additional, specify quantity before
NLC Night Light Circuit 2, 3
Philips Advance Mark 7 (0-10V)
nomenclature (Example: 2EL120).
GLR Fast Blow Fuse
EDULUTES
Universal
Voltage,
Lutron
EcoSystem
2
	Not available with all configurations; some limitations apply.
GMF Slow Blow Fuse
Digital Dimming Ballast 2, 4
Contact factory for details.
TBAR T-Bar Mounting
3
Unless specified, Alera will use fewest ballasts possible.
	One extra feed drop per EMC or NLC. (For through wiring,
WIH wiHUBB Enabled 2
contact factory.)
DSPL Philips LuxSense Daylight Sensor (Must Specify Philips
4
Lutron EcoSystem® series ballast. Contact factory for other
Advance 0-10V Dimming Ballast)2
Lutron ballasts.
DSL Lutron Daylight Sensor (Must Specify Lutron EcoSystem
5
Ships separately.
(EC5 Series)Dimming Ballast)2, 4
Model
CV Cûrv

Page 1/4 Rev. 06/26/13

housing type
S Solid

Protected by US Patent 6,796,676. Protected by Canada Patent 2,450,528. Specifications subject to change without notice.

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

curves / CV SOLID

CÛrv solid
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
Cross section

2½"

2½"

9½"
CV-1T8 SOLID

2½"

2½"

9½"
CV-2T8 SOLID

9½"
CV-4T8 SOLID

9½"
CV-3T8 SOLID

2½"

2½"

2½"

9½"
CV-1T5, T5HO SOLID

9½"
CV-3T5, T5HO SOLID

9½"
CV-2T5, T5HO SOLID

Photometric Data
Luminaire

Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet

CV-2T8-S-E
Cûrv Architectural Curve
9.5" × 48" 2-Lamp with
Solid White Reflector &
Spec Side Strips
B232I120RH-A
0.88
F32T8
2900
59
Pendant
0º = 90  90º = 00
0º = 0.00  90º = 0.00
Length: 3.54
Width: 0.33
Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
RC
80
70
50
Data not available.

RCR

Luminaire Data	 Test 12995

RW
1
2
3
4
5
6
7
8
9
10

70
83
75
69
63
57
52
48
44
41
38

50
79
69
60
53
47
42
37
34
30
28

30
76
64
54
46
40
35
30
27
24
21

10
73
59
49
41
35
30
26
22
19
17

70
71
64
58
53
49
45
41
38
35
33

50
68
59
52
46
40
36
32
29
26
24

30
65
55
47
40
35
30
26
23
21
18

10
62
51
43
36
30
26
22
19
17
15

50
46
41
36
31
28
25
22
20
18
17

30
45
38
32
28
24
21
19
16
15
13

10
43
36
30
25
21
18
16
14
12
11

Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0

180 165
1500

Zone

90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixt.
1849
2844
4478
5554
5554

31.9
49.0
77.2
95.8
95.8

33.3
51.2
80.6
100.0
100.0

135

120
750
105
90

RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary

150

75
750

Energy Data

60
95.8%
83
$2.89 based on 3000 hrs.
and $0.08 per KWH

Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Comparative Yearly Lighting
Energy Cost per 1000 Lumens

1500
0
0.0

15
30
Horiz 0-180
90.0
45.0

45

Test Date 12/17/01

Photometric Data
Luminaire

Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet

CV-2T8-S-E-HRF
Cûrv Architectural Curve
9.5" × 48" 2-Lamp with
Solid Highly Specular
Reflector
B232I120RH-A
0.88
F32T8
2900
59
Pendant
0º = 90  90º = 90
0º = 0.00  90º = 0.00
Length: 3.54
Width: 0.33
Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
RC
80
70
50
Data not available.

RCR

Luminaire Data	 Test 12996

RW
1
2
3
4
5
6
7
8
9
10

70
82
75
68
62
57
52
48
44
41
38

50
79
69
60
53
47
42
37
33
30
27

30
75
63
54
46
40
35
30
27
24
21

10
72
59
49
41
35
30
25
22
19
17

70
70
64
58
53
48
44
41
38
35
32

50
67
59
52
45
40
36
32
29
26
24

30
65
54
46
40
34
30
26
23
21
18

10
62
51
42
36
30
26
22
19
17
15

50
46
40
35
31
28
25
22
20
18
16

30
44
38
32
28
24
21
18
16
14
13

10
43
35
30
25
21
18
16
14
12
10

Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0

180 165
1800

150

120
900
105
90

RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary
Zone

90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixt.
1865
2972
4670
5518
5518

32.2
51.2
80.5
95.1
95.1

33.8
53.8
84.6
100.0
100.0

135

75
900

Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Comparative Yearly Lighting
Energy Cost per 1000 Lumens

95.1%
82
$2.93 based on 3000 hrs.
and $0.08 per KWH

60
1800
0
0.0

15
30
Horiz 0-180
90.0
45.0

45

Test Date 12/17/01
Page 2/4 Rev. 06/26/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

curves / CV SOLID

CÛrv solid
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
Photometric Data
Luminaire

Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet

CV-3T8-S-E-HRF
Cûrv Architectural Curve
9.5" × 48" 3-Lamp with
Solid Highly Specular
Reflector
B332I120RH-A
0.88
F32T8
2900
88
Pendant
0º = 90  90º = 00
0º = 0.00  90º = 0.00
Length: 3.54
Width: 0.33
Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
RC
80
70
50
Data not available.

RCR

Luminaire Data	 Test 12999

RW
1
2
3
4
5
6
7
8
9
10

70
82
75
68
62
57
52
48
44
41
38

50
78
68
60
53
47
42
37
33
30
27

30
75
63
54
46
40
35
30
27
24
21

10
72
59
49
41
35
30
25
22
19
17

70
70
64
58
53
48
44
41
38
35
32

50
67
59
51
45
40
36
32
29
26
24

30
64
54
46
40
34
30
26
23
21
18

10
62
51
42
35
30
26
22
19
17
15

50
46
40
35
31
28
25
22
20
18
16

30
44
38
32
28
24
21
18
16
14
13

10
43
35
30
25
21
18
16
14
12
10

Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0

180

Zone

90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixt.
2408
3996
6788
8268
8268

27.7
45.9
78.0
95.0
95.0

29.1
48.3
82.1
100.0
100.0

150

135

120
1300
105
90

RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary

165

2600

75
1300

Energy Data

60
95.0%
83
$2.89 based on 3000 hrs.
and $0.08 per KWH

Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Comparative Yearly Lighting
Energy Cost per 1000 Lumens

2600
0

15
30
Horiz 0-180
90.0
45.0

0.0

45

Test Date 1/11/02

Photometric Data
Luminaire

Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet

CV-1T5HO-S-EP
Cûrv Architectural Curve
9.5" × 48" 1-Lamp with
Solid White Refl & Spec
Side Strips
QT1X54/120PHO
1.00
F54T5
4400
61
Pendant
0º = 90  90º = 90
0º = 0.00  90º = 0.00
Length: 3.54
Width: 0.33
Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
RC
80
70
50
Data not available.

RCR

Luminaire Data	 Test 13004

RW
1
2
3
4
5
6
7
8
9
10

70
86
78
71
65
59
54
50
46
43
40

50
82
71
63
55
49
43
39
35
31
29

30
78
66
56
48
41
36
32
28
25
22

10
75
61
51
43
36
31
27
23
20
18

70
73
66
60
55
50
46
42
39
36
34

50
70
61
54
47
42
37
33
30
27
25

30
67
57
48
42
36
31
27
24
21
19

10
65
53
44
37
31
27
23
20
18
15

50
48
42
37
33
29
26
23
21
19
17

30
46
39
34
29
25
22
19
17
15
13

10
45
37
31
26
22
19
16
14
12
11

Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0

180 165
1400

Zone

90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixt.
1781
2515
3628
4361
4361

40.5
57.2
82.4
99.1
99.1

40.8
57.7
83.2
100.0
100.0

120
105
90
75
700

Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Comparative Yearly Lighting
Energy Cost per 1000 Lumens

135

700

RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary

150

60
99.1%
71
$3.38 based on 3000 hrs.
and $0.08 per KWH

1400
0
0.0

15
30
Horiz 0-180
90.0
45.0

45

Test Date 12/20/01

Page 3/4 Rev. 06/26/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

curves / CV SOLID

CÛrv solid
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
Photometric Data
Luminaire

Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet

CV-1t5ho-s-ep-hrf
Cûrv Architectural Curve
9.5" × 48" 1-Lamp with
Solid Highly Specular
Reflector
QT1X54/120PHO
1.00
F54T5
4400
61
Pendant
0º = 90  90º = 00
0º = 0.00  90º = 0.00
Length: 3.54
Width: 0.33
Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
RC
80
70
50
Data not available.

RCR

Luminaire Data	 Test 13011

RW
1
2
3
4
5
6
7
8
9
10

70
86
79
72
65
60
55
50
46
43
40

50
82
72
63
56
49
44
39
35
32
29

30
79
66
56
48
42
36
32
28
25
22

10
76
62
51
43
36
31
27
23
20
18

70
74
67
61
56
51
46
43
39
37
34

50
71
62
54
48
42
38
34
30
27
25

30
68
57
49
42
36
31
28
24
22
19

10
65
53
44
37
32
27
23
20
18
15

50
48
42
37
33
29
26
23
21
19
17

30
47
40
34
29
25
22
19
17
15
14

10
45
37
31
26
22
19
16
14
13
11

Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0

180 165
1700

150

120
850
105
90

RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary
Zone

90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixt.
1879
2769
3862
4393
4393

42.7
62.9
87.8
99.8
99.8

42.8
63.0
87.9
100.0
100.0

135

75
850

Energy Data

60

99.8%
72
$3.33 based on 3000 hrs.
and $0.08 per KWH

Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Comparative Yearly Lighting
Energy Cost per 1000 Lumens

1700
0

15
30
Horiz 0-180
90.0
45.0

0.0

45

Test Date 12/18/01

Photometric Data
Luminaire

Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet

CV-2T5HO-S-EP-HRF
Cûrv Architectural Curve
9.5" × 48" 2-Lamp
with Highly Specular
Reflector
QT2X54/120PHO
1.00
F54T5
4400
118
Pendant
0º = 90  90º = 90
0º = 0.00  90º = 0.00
Length: 3.54
Width: 0.33
Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
RC
80
70
50
Data not available.

RCR

Luminaire Data	 Test 13007

RW
1
2
3
4
5
6
7
8
9
10

70
85
77
70
64
59
54
49
46
42
39

50
81
71
62
55
48
43
38
35
31
28

30
78
65
56
48
41
36
31
28
24
22

10
74
61
50
42
36
31
26
23
20
17

70
73
66
60
55
50
46
42
39
36
33

50
69
61
53
47
42
37
33
30
27
24

30
67
56
48
41
36
31
27
24
21
19

10
64
53
44
37
31
27
23
20
17
15

50
47
42
37
32
29
25
23
21
19
17

30
46
39
33
29
25
22
19
17
15
13

10
44
37
31
26
22
19
16
14
12
11

Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0

180

Zone

90-120
90-130
90-150
90-180
0-180

Lumens % Lamp % Fixt.
3231
5057
7481
8644
8644

36.7
57.5
85.0
98.2
98.2

37.4
58.5
86.5
100.0
100.0

150

120
105
90
75
1700

Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Comparative Yearly Lighting
Energy Cost per 1000 Lumens

135

1700

RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Zonal Lumen Summary

165

3400

60

98.2%
73
$3.29 based on 3000 hrs.
and $0.08 per KWH

3400
0
0.0

15
30
Horiz 0-180
90.0
45.0

45

Test Date 12/27/01

Page 4/4 Rev. 06/26/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

curves / CV SOLID



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Instance ID                     : uuid:8c83e5f1-7e8a-b944-ac64-ef07a5a625b7
Original Document ID            : adobe:docid:indd:06f5464d-5038-11de-8cd8-e293284ac75d
Document ID                     : xmp.id:2D3A8BE8B72468118083EBD29EB3BC3C
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:2EC3A6C2E52068118083EBD29EB3BC3C
Derived From Document ID        : adobe:docid:indd:06f5464d-5038-11de-8cd8-e293284ac75d
Derived From Original Document ID: adobe:docid:indd:06f5464d-5038-11de-8cd8-e293284ac75d
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2013:06:30 21:20:54-04:00
Create Date                     : 2013:06:30 21:20:54-04:00
Modify Date                     : 2013:06:30 21:20:59-04:00
Metadata Date                   : 2013:06:30 21:20:59-04:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu