1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
CÛrv solid
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Page 1/4 Rev. 06/26/13
Catalog No.
Project Name Type
Date
PROJECT INFORMATION
MOUNTING METHOD
FCM18 Fixed Aircraft
Cable Mount
(Non-adjustable,
Std.) 18"
CM Adjustable
Aircraft Cable
Mount
ADJUSTABLE
CABLE LENGTH
48 48"
96 96"
Other lengths
available on
request.
CURVES / CV SOLID
CONSTRUCTION
—Housing provides indirect distribution of light
—Up to four T8 lamps and up to three T5 or T5HO lamps
—The exact shape of the housing is maintained by the
use of an inner die cast plate at each xture end.
—The housing is designed to wrap around the end
plates and secures on top with concealed screws to
ensure housing tolerances are consistent. These die
cast aluminum end caps and aligners provide zero
tolerance alignment between xtures, resulting in
consistently straight rows with no snaking.
—Reectors: standard with a painted white steel
reector with specular inserts on the side.
—High eciency reector (HRF) high reectance
specular material allows for wide distribution with
maximum eciency.
WR: An economical painted white reector
FINISH
The housing and all painted parts are treated with a
multi-stage phosphate bonding process before being
nished. Parts are then nished with a white RAL
powder coat nish for maximum consistent coverage
and longevity.
MOUNTING
—Aircraft cable suspension mechanism.
—Fixed cable has a total vertical adjustment
of 1¼".
End of cable barrel screws into a standard ¼-20
bolt brought down from the ceiling. A feed canopy
is provided for each feed location. All xtures are
suspended in modular increments and must be
supported at each xture-housing end.
LABELS AND ELECTRICAL
—All luminaires are built to UL1598 Standards and bear
appropriate UL and cUL or CSA labels. Damp location
labeling is standard.
— Quick-connect plugs standard.
CONTROLS COMPATIBILITY
Controls compatible. When used with Occupancy
Sensors, most lamp vendors recommend Program
Start ballast (EP) to extend lamp life. Common control
schemes: wiHUBB Enabled (WIH) switching (L/R or
IBOB), 0-10V dimming ballast (ED), Step Dimming
ballast (ESD), wiHUBB Enabled (WIH). Compatibility
with specic control (example, dimmer switch) is by
others. wiHUBB antenna will be visible. For daylight
sensors installed, see information below.
ARCHITECTURAL SENSORS INSTALLED
Daylight sensors are used to measure available sunlight
and reduce electric light for energy savings. Alera
sensors are installed to be both accessible and visible
below the housing.
DSPL: Philips Luxsense, Mark 7 0-10V dimming ballast.
Closed loop sensor measures reected light in a cone
below the sensor. Pre-commissioned by Philips to 45fc
standard; modest manual adjustability via sensor ring.
DSL: Lutron EcoSystem, digital dimming ballast.
Open loop sensor must be pointed directly at the
source of natural light. System requires proprietary
commissioning by others.
Additional technical data: see TID sheets, Alera website
and sensor manufacturer websites.
FEATURES
2½" deep housing for a sleek modern appearance
Indirect Luminaire
Unique lamp crossing technique on one and three
lamp models maintains 48" modularity
Heavy 20-gauge steel construction provides
excellent housing rigidity
Controls compatible
Available with optional installed open or closed
loop daylight sensors (DSPL, DSL) when daylight
dimming systems are desired
Solid housing for 100% uplight
Unique die cast aluminum, tongue and groove
couplers provide zero tolerance alignment resulting
in consistently straight rows
Patented die cast aluminum end caps for a soft
nished appearance (Patent# 6,796,676B2)
Flat end caps standard
Modular mounting points for convenient hanging
locations
Available with exclusive wiHUBB technology
preinstalled (WIH option)
– Peer to peer, self-healing wireless mesh
network
– Integrated control system for 0-10VDC or
step dimming, or On/O
EXAMPLE: CV-8-2T8-S-CM48-EU-MW
ORDERING INFORMATION
OPTIONS
WR White Reflector
HRF High Efficiency Reflector
DC Dust Cover (N/A T5HO)5
SCE Sculpted End Cap (5⁄")5
BN Bull Nose End Cap (5⁄")5
LR Left/Right Switching (2-Lamp only)
IBOB Inboard/Outboard Switching (3-Lamp only)
F0841 With T8 4100L Lamp Installed
F5841 With T5(HO) 4100K Lamp Installed
F0835 With T8 3500K Lamp Installed
F5835 With T5(HO) 3500K Lamp Installed
EL One Emergency Battery Pack1, 2
EMC One Emergency Circuit2, 3
NLC Night Light Circuit2, 3
GLR Fast Blow Fuse
GMF Slow Blow Fuse
TBAR T-Bar Mounting
WIH wiHUBB Enabled 2
DSPL Philips LuxSense Daylight Sensor (Must Specify Philips
Advance 0-10V Dimming Ballast)2
DSL Lutron Daylight Sensor (Must Specify Lutron EcoSystem
(EC5 Series)Dimming Ballast)2, 4
1 Specify voltage. For additional, specify quantity before
nomenclature (Example: 2EL120).
2 Not available with all configurations; some limitations apply.
Contact factory for details.
3 One extra feed drop per EMC or NLC. (For through wiring,
contact factory.)
4 Lutron EcoSystem® series ballast. Contact factory for other
Lutron ballasts.
5 Ships separately.
S
HOUSING TYPE
SSolid
SHAPE AND DIMENSIONS
9½"
2½"
Name: CV-1T8-S-E-WR
Test #: 12991
Eciency: 97.2%
LER: 86
A
R
C
H
I
T
E
C
T
U
R
A
L
S
E
N
S
O
R
S
Protected by US Patent 6,796,676. Protected by Canada Patent 2,450,528. Specications subject to change without notice.
CV
MODEL
CV Cûrv
ROW LENGTH
44' Single
88' Single
12 12' Single
Indicate row length
over 12' in 4'
increments
Note: Rows over 12' will
be configured by Alera.
Example: 16' will be (2) 8'.
Alternate configurations:
contact factory.
LAMP TYPE AND PROFILE
1T5 One T5 Lamp
2T5 Two T5 Lamps
3T5 Three T5 Lamps
1T5HO One T5HO Lamp
2T5HO Two T5HO Lamps
3T5HO Three T5HO Lamps
2T8 Two T8 Lamps
3T8 Three T8 Lamps
4T8 Four T8 Lamps
BALLAST
EElectronic, Instant Start (Std. for T8)
EP Electronic, Programmed Start (Std. for T5
& T5HO, optional for T8)
ELW Electronic T8, Low Wattage, Instant Start
EPLW Electronic T8, Low Wattage, Programmed
Start
ED Electronic, Dimming (Must specify)
ESD Electronic, Step Dimming
EDUMK7 Universal Voltage, Electronic Dimming
Philips Advance Mark 7 (0-10V)
EDULUTES Universal Voltage, Lutron EcoSystem
Digital Dimming Ballast 2, 4
Unless specified, Alera will use fewest ballasts possible.
VOLTAGE
U120V-277V
120 120V
277 277V
347 347V
— —
FINISH
MW Matte White (Std.)
ZT ZET Metallic Silver
See Color Selection Guide
for other colors.
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
CÛrv solid
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Page 2/4 Rev. 06/26/13
750
1500
750
1500
015 30 45
90
75
60
105
120
180 165 150 135
Horiz 0-180
0.0 45.0 90.0
900
1800
900
1800
015 30 45
90
75
60
105
120
180 165 150 135
Horiz 0-180
0.0 45.0 90.0
CURVES / CV SOLID
CROSS SECTION
CV-1T8 SOLID
2½"
9½"
Zone Lumens % Lamp % Fixt.
90-120 1849 31.9 33.3
90-130 2844 49.0 51.2
90-150 4478 77.2 80.6
90-180 5554 95.8 100.0
0-180 5554 95.8 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
183 79 76 73 71 68 65 62 46 45 43 0
275 69 64 59 64 59 55 51 41 38 36 0
369 60 54 49 58 52 47 43 36 32 30 0
463 53 46 41 53 46 40 36 31 28 25 0
557 47 40 35 49 40 35 30 28 24 21 0
652 42 35 30 45 36 30 26 25 21 18 0
748 37 30 26 41 32 26 22 22 19 16 0
844 34 27 22 38 29 23 19 20 16 14 0
941 30 24 19 35 26 21 17 18 15 12 0
10 38 28 21 17 33 24 18 15 17 13 11 0
Luminaire CV-2T8-S-E
Cûrv Architectural Curve
9.5" × 48" 2-Lamp with
Solid White Reector &
Spec Side Strips
Ballast B232I120RH-A
Ballast Factor 0.88
Lamp F32T8
Lumens per Lamp 2900
Watts 59
Mounting Pendant
Shielding Angle 0º = 90 90º = 00
Spacing Criterion 0º = 0.00 90º = 0.00
Luminous
Opening in Feet
Length: 3.54
Width: 0.33
Height: 0.00
Total Luminaire Eciency 95.8%
Luminaire Ecacy Rating (LER) 83
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$2.89 based on 3000 hrs.
and $0.08 per KWH
LUMINAIRE DATA Test 12995
Test Date 12/17/01
Zone Lumens % Lamp % Fixt.
90-120 1865 32.2 33.8
90-130 2972 51.2 53.8
90-150 4670 80.5 84.6
90-180 5518 95.1 100.0
0-180 5518 95.1 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
182 79 75 72 70 67 65 62 46 44 43 0
275 69 63 59 64 59 54 51 40 38 35 0
368 60 54 49 58 52 46 42 35 32 30 0
462 53 46 41 53 45 40 36 31 28 25 0
557 47 40 35 48 40 34 30 28 24 21 0
652 42 35 30 44 36 30 26 25 21 18 0
748 37 30 25 41 32 26 22 22 18 16 0
844 33 27 22 38 29 23 19 20 16 14 0
941 30 24 19 35 26 21 17 18 14 12 0
10 38 27 21 17 32 24 18 15 16 13 10 0
Total Luminaire Eciency 95.1%
Luminaire Ecacy Rating (LER) 82
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$2.93 based on 3000 hrs.
and $0.08 per KWH
Test Date 12/17/01
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
PHOTOMETRIC DATA
PHOTOMETRIC DATA
COEFFICIENTS OF UTILIZATION (%)
COEFFICIENTS OF UTILIZATION (%)
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
INDOOR CANDELA PLOT
INDOOR CANDELA PLOT
ENERGY DATA
ENERGY DATA
Luminaire CV-2T8-S-E-HRF
Cûrv Architectural Curve
9.5" × 48" 2-Lamp with
Solid Highly Specular
Reector
Ballast B232I120RH-A
Ballast Factor 0.88
Lamp F32T8
Lumens per Lamp 2900
Watts 59
Mounting Pendant
Shielding Angle 0º = 90 90º = 90
Spacing Criterion 0º = 0.00 90º = 0.00
Luminous
Opening in Feet
Length: 3.54
Width: 0.33
Height: 0.00
LUMINAIRE DATA Test 12996
CV-2T8 SOLID
2½"
9½"
CV-3T8 SOLID
2½"
9½"
CV-4T8 SOLID
2½"
9½"
CV-1T5, T5HO SOLID
2½"
9½"
CV-2T5, T5HO SOLID
2½"
9½"
CV-3T5, T5HO SOLID
2½"
9½"
AVG. LUMINANCE (Candela/Sq. M.)
AVG. LUMINANCE (Candela/Sq. M.)
Data not available.
Data not available.
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
CÛrv solid
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Page 3/4 Rev. 06/26/13
1300
2600
1300
2600
015 30 45
90
75
60
105
120
180 165 150 135
Horiz 0-180
0.0 45.0 90.0
700
1400
700
1400
015 30 45
90
75
60
105
120
180 165 150 135
Horiz 0-180
0.0 45.0 90.0
CURVES / CV SOLID
Zone Lumens % Lamp % Fixt.
90-120 2408 27.7 29.1
90-130 3996 45.9 48.3
90-150 6788 78.0 82.1
90-180 8268 95.0 100.0
0-180 8268 95.0 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
182 78 75 72 70 67 64 62 46 44 43 0
275 68 63 59 64 59 54 51 40 38 35 0
368 60 54 49 58 51 46 42 35 32 30 0
462 53 46 41 53 45 40 35 31 28 25 0
557 47 40 35 48 40 34 30 28 24 21 0
652 42 35 30 44 36 30 26 25 21 18 0
748 37 30 25 41 32 26 22 22 18 16 0
844 33 27 22 38 29 23 19 20 16 14 0
941 30 24 19 35 26 21 17 18 14 12 0
10 38 27 21 17 32 24 18 15 16 13 10 0
Luminaire CV-3T8-S-E-HRF
Cûrv Architectural Curve
9.5" × 48" 3-Lamp with
Solid Highly Specular
Reector
Ballast B332I120RH-A
Ballast Factor 0.88
Lamp F32T8
Lumens per Lamp 2900
Watts 88
Mounting Pendant
Shielding Angle 0º = 90 90º = 00
Spacing Criterion 0º = 0.00 90º = 0.00
Luminous
Opening in Feet
Length: 3.54
Width: 0.33
Height: 0.00
Total Luminaire Eciency 95.0%
Luminaire Ecacy Rating (LER) 83
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$2.89 based on 3000 hrs.
and $0.08 per KWH
LUMINAIRE DATA Test 12999
Test Date 1/11/02
Zone Lumens % Lamp % Fixt.
90-120 1781 40.5 40.8
90-130 2515 57.2 57.7
90-150 3628 82.4 83.2
90-180 4361 99.1 100.0
0-180 4361 99.1 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
186 82 78 75 73 70 67 65 48 46 45 0
278 71 66 61 66 61 57 53 42 39 37 0
371 63 56 51 60 54 48 44 37 34 31 0
465 55 48 43 55 47 42 37 33 29 26 0
559 49 41 36 50 42 36 31 29 25 22 0
654 43 36 31 46 37 31 27 26 22 19 0
750 39 32 27 42 33 27 23 23 19 16 0
846 35 28 23 39 30 24 20 21 17 14 0
943 31 25 20 36 27 21 18 19 15 12 0
10 40 29 22 18 34 25 19 15 17 13 11 0
Total Luminaire Eciency 99.1%
Luminaire Ecacy Rating (LER) 71
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$3.38 based on 3000 hrs.
and $0.08 per KWH
Test Date 12/20/01
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
PHOTOMETRIC DATA
PHOTOMETRIC DATA
COEFFICIENTS OF UTILIZATION (%)
COEFFICIENTS OF UTILIZATION (%)
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
INDOOR CANDELA PLOT
INDOOR CANDELA PLOT
ENERGY DATA
ENERGY DATA
Luminaire CV-1T5HO -S-EP
Cûrv Architectural Curve
9.5" × 48" 1-Lamp with
Solid White Re & Spec
Side Strips
Ballast QT1X54/120PHO
Ballast Factor 1.00
Lamp F54T5
Lumens per Lamp 4400
Watts 61
Mounting Pendant
Shielding Angle 0º = 90 90º = 90
Spacing Criterion 0º = 0.00 90º = 0.00
Luminous
Opening in Feet
Length: 3.54
Width: 0.33
Height: 0.00
LUMINAIRE DATA Test 13004
AVG. LUMINANCE (Candela/Sq. M.)
AVG. LUMINANCE (Candela/Sq. M.)
Data not available.
Data not available.
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
CÛrv solid
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Page 4/4 Rev. 06/26/13
850
1700
850
1700
015 30 45
90
75
60
105
120
180 165 150 135
Horiz 0-180
0.0 45.0 90.0
1700
3400
1700
3400
015 30 45
90
75
60
105
120
180 165 150 135
Horiz 0-180
0.0 45.0 90.0
CURVES / CV SOLID
Zone Lumens % Lamp % Fixt.
90-120 1879 42.7 42.8
90-130 2769 62.9 63.0
90-150 3862 87.8 87.9
90-180 4393 99.8 100.0
0-180 4393 99.8 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
186 82 79 76 74 71 68 65 48 47 45 0
279 72 66 62 67 62 57 53 42 40 37 0
372 63 56 51 61 54 49 44 37 34 31 0
465 56 48 43 56 48 42 37 33 29 26 0
560 49 42 36 51 42 36 32 29 25 22 0
655 44 36 31 46 38 31 27 26 22 19 0
750 39 32 27 43 34 28 23 23 19 16 0
846 35 28 23 39 30 24 20 21 17 14 0
943 32 25 20 37 27 22 18 19 15 13 0
10 40 29 22 18 34 25 19 15 17 14 11 0
Luminaire CV-1T5HO-S-EP-HRF
Cûrv Architectural Curve
9.5" × 48" 1-Lamp with
Solid Highly Specular
Reector
Ballast QT1X54/120PHO
Ballast Factor 1.00
Lamp F54T5
Lumens per Lamp 4400
Watts 61
Mounting Pendant
Shielding Angle 0º = 90 90º = 00
Spacing Criterion 0º = 0.00 90º = 0.00
Luminous
Opening in Feet
Length: 3.54
Width: 0.33
Height: 0.00
Total Luminaire Eciency 99.8%
Luminaire Ecacy Rating (LER) 72
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$3.33 based on 3000 hrs.
and $0.08 per KWH
LUMINAIRE DATA Test 13011
Test Date 12/18/01
Zone Lumens % Lamp % Fixt.
90-120 3231 36.7 37.4
90-130 5057 57.5 58.5
90-150 7481 85.0 86.5
90-180 8644 98.2 100.0
0-180 8644 98.2 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
185 81 78 74 73 69 67 64 47 46 44 0
277 71 65 61 66 61 56 53 42 39 37 0
370 62 56 50 60 53 48 44 37 33 31 0
464 55 48 42 55 47 41 37 32 29 26 0
559 48 41 36 50 42 36 31 29 25 22 0
654 43 36 31 46 37 31 27 25 22 19 0
749 38 31 26 42 33 27 23 23 19 16 0
846 35 28 23 39 30 24 20 21 17 14 0
942 31 24 20 36 27 21 17 19 15 12 0
10 39 28 22 17 33 24 19 15 17 13 11 0
Total Luminaire Eciency 98.2%
Luminaire Ecacy Rating (LER) 73
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$3.29 based on 3000 hrs.
and $0.08 per KWH
Test Date 12/27/01
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Luminaire CV-2T5HO-S-EP-HRF
Cûrv Architectural Curve
9.5" × 48" 2-Lamp
with Highly Specular
Reector
Ballast QT2X54/120PHO
Ballast Factor 1.00
Lamp F54T5
Lumens per Lamp 4400
Watts 118
Mounting Pendant
Shielding Angle 0º = 90 90º = 90
Spacing Criterion 0º = 0.00 90º = 0.00
Luminous
Opening in Feet
Length: 3.54
Width: 0.33
Height: 0.00
LUMINAIRE DATA Test 13007
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
PHOTOMETRIC DATA
PHOTOMETRIC DATA
COEFFICIENTS OF UTILIZATION (%)
COEFFICIENTS OF UTILIZATION (%)
INDOOR CANDELA PLOT
INDOOR CANDELA PLOT
ENERGY DATA
ENERGY DATA
AVG. LUMINANCE (Candela/Sq. M.)
AVG. LUMINANCE (Candela/Sq. M.)
Data not available.