Design And Drawing
2017-12-08
: Pdf Design--And-Drawing design--and-drawing uploads
Open the PDF directly: View PDF
.
Page Count: 77
| Download | |
| Open PDF In Browser | View PDF |
DRAWING CREATED 2010-01-15 8420 in. (mm) POST TYPE INSULATOR TR-202 TR-202 METAL CAP BOTH ENDS 4 TAPPED HOLES Ø1/2"-13+.015 OVERSIZE .62 (16) MIN. FULL THREAD ON 3.0 (76) B.C. BOTH ENDS. Reference Color 084201111 084201101 LT. GRAY No. 70 BROWN Ø4.25 (108) MARK 7.5 (191) Ø7.0 (178) NOTE: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER. DWG. No. P:8420 /8420-CLIENTE DWG. No.TYPE SALES Autocad 2000 DWN. L.E. RINCÓN APP. A.I.PÉREZ DRAWING CREATED 2010-01-14 8425 in. (mm) POST TYPE INSULATOR TR-205 TR-205 METAL CAP BOTH ENDS 4 TAPPED HOLES Ø1/2"-13+.015 OVERSIZE .62 (16) MIN. FULL THREAD ON 3.0 (76) B.C. BOTH ENDS. Reference Color 084251111 084251101 LT. GRAY No. 70 BROWN Ø4.25 (108) MARK 10.0 (254) Ø7 (178) NOTE: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER. DWG. No. P:8425 /8425-CLIENTE DWG. No.TYPE SALES Autocad 2000 DWN. L.E. RINCÓN APP. A.I.PÉREZ DRAWING CREATED 2010-01-14 8428 in. (mm) POST TYPE INSULATOR TR-208 TR-208 METAL CAP BOTH ENDS 4 TAPPED HOLES Ø1/2"-13+.015 OVERSIZE .62 (16) MIN. FULL THREAD ON 3.0 (76) B.C. BOTH ENDS. Reference Color 084281111 084281101 LT. GRAY No. 70 BROWN Ø4.25 (108) MARK 14 (356) Ø6.5 (167) NOTE: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER. DWG. No. P:8428 /8428-CLIENTE DWG. No.TYPE SALES Autocad 2000 DWN. L.E. RINCÓN APP. A.I.PÉREZ DRAWING CREATED 2010-01-14 8430 in. (mm) POST TYPE INSULATOR TR-210 TR-210 METAL CAP BOTH ENDS 4 TAPPED HOLES Ø1/2"-13+.015 OVERSIZE .62 (16) MIN. FULL THREAD ON 3.0 (76) B.C. BOTH ENDS. Ø3.0 (76) Ø4.25 (108) MARK Reference Color 084301111 084301101 LT. GRAY No. 70 BROWN 18.0 (457) Ø7.5 (191) NOTE: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED DWG. No. P:8430 /8430-CLIENTE DWG. No.TYPE SALES Autocad 2000 DWN. L.E. RINCÓN APP. A.I.PÉREZ DRAWING CREATED 2010-01-14 8435 in. (mm) POST TYPE INSULATOR TR-214 TR-214 METAL CAP BOTH ENDS 4 TAPPED HOLES Ø1/2"-13+.015 OVERSIZE .62 (16) MIN. FULL THREAD ON 3.0 (76) B.C. BOTH ENDS. Ø4.25 (108) MARK Reference Color 084351111 084351101 LT. GRAY No. 70 BROWN 22.0 (559) Ø7.7 (178) NOTE: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER. DWG. No. P:8435 /8435-CLIENTE DWG. No.TYPE SALES Autocad 2000 DWN. L.E. RINCÓN APP. A.I.PÉREZ DRAWING CREATED 2010-01-15 8436 in. (mm) POST TYPE INSULATOR TR-216 TR-216 METAL CAP BOTH ENDS MARK 4 TAPPED HOLES Ø1/2"-13+.015 OVERSIZE .62 (16) MIN. FULL THREAD ON 3.0 (76) B.C. BOTH ENDS. Ø4.25 (108) Reference Color 084361111 084361101 LT. GRAY No. 70 BROWN 30.0 (762) Ø8.1 (205) NOTE: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER. DWG. No. P:8436 /8436-CLIENTE DWG. No.TYPE SALES Autocad 2000 DWN. L.E. RINCÓN APP. A.I.PÉREZ Technical reference number: TR 286 EUROPE BIL 550 kV Top Flange View PART NUMBER CERISOL in (mm) TITLE 286SU0550 STATION POST INSULATOR. STANDARD STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø5.0 (Ø127) CERISOL EUROPE Year-month Serial number 286SU0550 TR286 SC907 Ø6.22 (Ø158) Unit Part n° Unit Shed ID Weight: Fixation: Top / Bottom S2907EJ TR286 SC907 143 lb 65 kg 4 holes 5/8-11UNC 4 holes 5/8-11UNC NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 (21 Sheds) 45.0 ±0.06 (1143 ±1.6) Ø8.46 (Ø215) DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 101 99 (2565) (2515) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1700 1700 20000 40000 60000 (7562) (7562) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 610 230 550 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 73 200 Other characteristics: Insulating material: Glaze: Ø8.46 (Ø215) Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Shed Profile 18° Ø6.22 (Ø158) R 0.19 (5) Ø5.0 (Ø127) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Bottom Flange View NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 1.69 (43) 10° 1.77 (45) DWG. No.: H21286EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: TR 287 EUROPE BIL 550 kV Top Flange View PART NUMBER CERISOL in (mm) TITLE 287HU0550 STATION POST INSULATOR. HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks CERISOL Ø5.0 (Ø127) EUROPE Year-month Serial number 287HU0550 TR287 SC914 Ø6.3 (Ø160) Unit Part n° Unit Shed ID Weight: Fixation: Top / Bottom S2914EJ TR287 SC914 172 lb 78 kg 4 holes 5/8-11UNC 4 holes 5/8-11UNC NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 (21 Sheds) 45.0 ±0.06 (1143 ±1.6) Ø9.41 (Ø239) DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 101 99 (2565) (2515) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 2600 2600 25000 90000 75000 (11565) (11565) (112000) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 610 230 550 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 73 200 Other characteristics: Insulating material: Glaze: Ø9.41 (Ø239) Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Shed Profile 18° Ø6.3 (Ø160) R 0.19 (5) Ø5.0 (Ø127) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Bottom Flange View NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 1.69 (43) 10° 1.77 (45) DWG. No.: H21287EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: TR 288 EUROPE BIL 650 kV Top Flange View PART NUMBER CERISOL in (mm) TITLE 288SU0650 STATION POST INSULATOR. STANDARD STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø5.0 (Ø127) CERISOL EUROPE Year-month Serial number 288SU0650 TR288 SC6905 Ø6.22 (Ø158) Ø8.46 (Ø215) Unit Part n° Unit Shed ID Weight: Fixation: Top / Bottom S26905EJ TR288 SC6905 159 lb 72 kg 4 holes 5/8-11UNC 4 holes 5/8-11UNC (25 Sheds) 54.0 ±0.06 (1372 ±1.6) NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 121 116 (3073) (2946) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1400 1400 20000 40000 60000 (6227) (6227) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 710 275 650 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 88 200 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Ø8.46 (Ø215) Shed Profile 18° Ø6.22 (Ø158) R 0.19 (5) Ø5.0 (Ø127) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Bottom Flange View NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 1.77 (45) 10° 1.77 (45) DWG. No.: H21288EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: TR 289 EUROPE BIL 650 kV Top Flange View PART NUMBER CERISOL in (mm) TITLE 289HU0650 STATION POST INSULATOR. HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø5.0 (Ø127) CERISOL EUROPE Year-month Serial number 289HU0650 TR289 SC913 Ø6.3 (Ø160) Ø9.06 (Ø230) Unit Part n° Unit Shed ID Weight: Fixation: Top / Bottom S2913EJ TR289 SC913 201 lb 91 kg 4 holes 5/8-11UNC 4 holes 5/8-11UNC (25 Sheds) 54.0 ±0.06 (1372 ±1.6) NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 121 116 (3073) (2946) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 2200 2200 25000 90000 75000 (9786) (9786) (88960) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 710 275 650 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 88 200 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Ø9.06 (Ø230) Shed Profile 18° Ø6.3 (Ø160) R 0.19 (5) Ø5.0 (Ø127) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Bottom Flange View NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 1.77 (45) 10° 1.77 (45) DWG. No.: H21289EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: TR 291 EUROPE BIL 750 kV Top Flange View PART NUMBER CERISOL in (mm) TITLE 291SU0750 STATION POST INSULATOR. STANDARD STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø5.0 (Ø127) CERISOL EUROPE Year-month Serial number 291SU0750 TR291 SC911 Ø6.22 (Ø158) Unit Part n° Unit Shed ID Weight: Fixation: Top / Bottom S2911EJ TR291 SC911 185 lb 84 kg 4 holes 5/8-11UNC 4 holes 5/8-11UNC Ø8.78 (Ø223) (27 Sheds) 62.0 ±0.09 (1575 ±2.4) NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 134 132 (3404) (3353) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1200 1200 20000 40000 60000 (5338) (5338) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 810 315 750 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 103 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Ø8.78 (Ø223) Shed Profile 18° R 0.19 (5) Ø6.22 (Ø158) Ø5.0 (Ø127) Bottom Flange View NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) 1.92 (49) 10° 1.77 (45) DWG. No.: H21291EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: TR 295 EUROPE BIL 750 kV Top Flange View PART NUMBER CERISOL in (mm) TITLE 295HU0750 STATION POST INSULATOR. HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø5.0 (Ø127) CERISOL EUROPE Year-month Serial number 295HU0750 TR295 SC916 Ø6.3 (Ø160) Unit Part n° Unit Shed ID Weight: Fixation: Top / Bottom S2916EJ TR295 SC916 230 lb 104 kg 4 holes 5/8-11UNC 4 holes 5/8-11UNC Ø9.53 (Ø242) (27 Sheds) 62.0 ±0.09 (1575 ±2.4) NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 134 132 (3404) (3353) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1850 1850 25000 90000 75000 (8229) (8229) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 810 315 750 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 103 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Ø9.53 (Ø242) Shed Profile 18° R 0.19 (5) Ø6.3 (Ø160) Ø5.0 (Ø127) Bottom Flange View NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) 1.92 (49) 10° 1.77 (45) DWG. No.: H21295EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 304 EUROPE BIL 900 kV TITLE STATION POST INSULATOR. STANDARD STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Top Flange View Ø5.0 (Ø127) Marks Ø6.22 (Ø158) EUROPE (20 Sheds) 40.0 (1016) Ø8.39 (Ø213) 80.0 ±0.13 (2032 ±3.2) Ø9.25 (Ø235) Ø7.87 (Ø200) (20 Sheds) 40.0 (1016) Ø8.39 (Ø213) S2912EJ UNIT 2 S3912EJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 128 lb 4 holes 5/8-11UNC 58 kg 4xØ18xØ200 128 lb 4xØ18xØ200 58 kg 4 holes 5/8-11UNC 256 lb 116 kg (4343) (4191) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 950 950 20000 40000 60000 (4226) (4226) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1010 385 900 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° 10° 1.53 (39) Ø6.22 (Ø158) Bottom Flange View 4xM16 Bolts 4xM16 Nuts 4 Washers 171 165 R 0.19 (5) Ø5.0 (Ø127) Galvanized Steel: DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) Ø8.39 (Ø213) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER UNIT 1 Unit Shed ID TR304 SC912 TR304 SC912 NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.39 (Ø213) UNIT 2 Unit Part n° CERISOL Year-month Serial number 304SU0900 TR304 SC912 UNIT 1 304SU0900 in (mm) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) 1.57 (40) DWG. No.: H21304EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 308 EUROPE BIL 900 kV in (mm) TITLE STATION POST INSULATOR. HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Top Flange View Ø5.0 (Ø127) Marks Ø6.3 (Ø160) Unit Part n° CERISOL EUROPE Year-month Serial number 308HT0900 TR308 SC6904 UNIT 1 UNIT 2 (20 Sheds) 40.0 (1016) Ø9.33 (Ø237) UNIT 1 Ø10.24 (Ø260) Ø8.86 (Ø225) (20 Sheds) 40.0 (1016) Ø9.33 (Ø237) Unit Shed ID TR308 S26904EJ SC6904 TR308 S36904EJ SC6904 Total Weight: Assembly: Fixation: Weight: Top / Bottom 174 lb 4 holes 5/8-11UNC 79 kg 4xØ18xØ225 174 lb 4xØ18xØ225 79 kg 4 holes 5/8-11UNC 348 lb 158 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 80.0 ±0.13 (2032 ±3.2) Ø9.33 (Ø237) UNIT 2 308HT0900 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 170 165 (4318) (4191) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1450 25000 90000 75000 (6450) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1010 385 900 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) R 0.19 (5) 10° Ø5.0 (Ø127) Bottom Flange View 1.53 (39) Ø6.3 (Ø160) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 18° Ø9.33 (Ø237) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) 1.57 (40) DWG. No.: H21307EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 308 EUROPE BIL 900 kV in (mm) TITLE STATION POST INSULATOR. HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Top Flange View Ø5.0 (Ø127) Marks Ø6.3 (Ø160) EUROPE (20 Sheds) 40.0 (1016) Ø9.33 (Ø237) Ø10.24 (Ø260) Ø8.86 (Ø225) (20 Sheds) 40.0 (1016) Ø9.33 (Ø237) UNIT 2 Total Weight: Assembly: Fixation: Weight: Top / Bottom 174 lb 4 holes 5/8-11UNC 79 kg 4xØ18xØ225 174 lb 4xØ18xØ225 79 kg 4 holes 5/8-11UNC 348 lb 158 kg (4318) (4191) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1450 1450 25000 90000 75000 (6450) (6450) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1010 385 900 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° 10° 1.53 (39) Ø6.3 (Ø160) Bottom Flange View 4xM16 Bolts 4xM16 Nuts 4x Washers 170 165 R 0.19 (5) Ø5.0 (Ø127) Galvanized Steel: DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) Ø9.33 (Ø237) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER UNIT 1 Unit Shed ID TR308 S26904EJ SC6904 TR308 S36904EJ SC6904 NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 80.0 ±0.13 (2032 ±3.2) Ø9.33 (Ø237) UNIT 2 Unit Part n° CERISOL Year-month Serial number 308HU0900 TR308 SC6904 UNIT 1 308HU0900 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) 1.57 (40) DWG. No.: H21308EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 312 EUROPE BIL 1050 kV 312ST1050 in (mm) TITLE STATION POST INSULATOR. STANDARD STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.22 (Ø158) Unit Part n° CERISOL EUROPE Year-month Serial number 312ST1050 TR312 SC907 (21 Sheds) 46.0 (1168.5) Ø8.46 (Ø215) UNIT 1 92.0 ±0.13 (2337 ±3.2) Ø7.87 (Ø200) (21 Sheds) 46.0 (1168.5) Ø8.46 (Ø215) UNIT 2 S3907MJ UNIT 2 S4907MJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 137 lb 4 holes 5/8-11UNC 62 kg 4xØ18xØ200 137 lb 4xØ18xØ200 62 kg 4 holes 5/8-11UNC 274 lb 124 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.46 (Ø215) Ø9.25 (Ø235) UNIT 1 Unit Shed ID TR312 SC907 TR312 SC907 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 202 198 (5131) (5030) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 800 20000 40000 60000 (3558) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1210 455 1050 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) Ø8.46 (Ø215) 1.39 (43) 10° Ø6.22 (Ø158) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 1.77 (45) DWG. No.: H21312EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 312 U EUROPE BIL 1050 kV 312SU1050 in (mm) TITLE STATION POST INSULATOR. STANDARD STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.22 (Ø158) Unit Part n° CERISOL EUROPE Year-month Serial number 312SU1050 TR312 SC907 (21 Sheds) 46.0 (1168.5) Ø8.46 (Ø215) UNIT 1 92.0 ±0.13 (2337 ±3.2) Ø7.87 (Ø200) (21 Sheds) 46.0 (1168.5) Ø8.46 (Ø215) UNIT 2 S3907MJ UNIT 2 S4907MJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 137 lb 4 holes 5/8-11UNC 62 kg 4xØ18xØ200 137 lb 4xØ18xØ200 62 kg 4 holes 5/8-11UNC 274 lb 124 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.46 (Ø215) Ø9.25 (Ø235) UNIT 1 Unit Shed ID TR312 SC907 TR312 SC907 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 202 198 (5131) (5030) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 800 800 20000 40000 60000 (3558) (3558) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1210 455 1050 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) Ø8.46 (Ø215) 1.39 (43) 10° Ø6.22 (Ø158) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 1.77 (45) DWG. No.: H21313EJ DWG: TYPE SALES Date: 2015/07/22 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 316 EUROPE BIL 1050 kV 316HT1050 in (mm) TITLE STATION POST INSULATOR. HIGH STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.22 (Ø158) Unit Part n° CERISOL EUROPE Year-month Serial number 316HT1050 TR316 SC924 (Unit 1) SC914 (Unit 2) (21 Sheds) 46.0 (1168.5) Ø8.98 (Ø228) UNIT 1 92.0 ±0.13 (2337 ±3.2) Ø8.86 (Ø225) (21 Sheds) 46.0 (1168.5) Ø9.41 (Ø239) UNIT 2 S2924EJ UNIT 2 S4914MJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 155 lb 4 holes 5/8-11UNC 70 kg 4xØ18xØ225 183 lb 4xØ18xØ225 83 kg 4 holes 5/8-11UNC 338 lb 153 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.98 (Ø228) Ø10.24 (Ø260) UNIT 1 Unit Shed ID TR316 SC924 TR316 SC914 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 202 198 (5131) (5030) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1250 25000 90000 75000 (5560) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1210 455 1050 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) Ø9.41 (Ø239) 1.39 (43) 10° Ø6.3 (Ø160) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 1.77 (45) DWG. No.: H21316EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 316 U EUROPE BIL 1050 kV 316HU1050 in (mm) TITLE STATION POST INSULATOR. HIGH STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.3 (Ø160) Unit Part n° CERISOL EUROPE Year-month Serial number 316HU1050 TR316 SC914 (21 Sheds) 46.0 (1168.5) Ø9.41 (Ø239) UNIT 1 92.0 ±0.13 (2337 ±3.2) Ø8.86 (Ø225) (21 Sheds) 46.0 (1168.5) Ø9.41 (Ø239) UNIT 2 S3914MJ UNIT 2 S4914MJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 183 lb 4 holes 5/8-11UNC 83 kg 4xØ18xØ225 183 lb 4xØ18xØ225 83 kg 4 holes 5/8-11UNC 366 lb 166 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø9.41 (Ø239) Ø10.24 (Ø260) UNIT 1 Unit Shed ID TR316 SC914 TR316 SC914 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 202 198 (5131) (5030) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1250 1250 25000 90000 75000 (5560) (5560) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1210 455 1050 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) Ø9.41 (Ø239) 1.39 (43) 10° Ø6.3 (Ø160) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 1.77 (45) DWG. No.: H21317EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 324 EUROPE BIL 1300 kV 324ST1300 in (mm) TITLE STATION POST INSULATOR. STANDARD STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.22 (Ø158) Unit Part n° CERISOL EUROPE Year-month Serial number 324ST1300 TR324 SC905 (Unit 1) SC915 (Unit 2) (25 Sheds) 53.15 (1350) Ø8.46 (Ø215) 106.0 ±0.16 (2692 ±4) Ø8.86 (Ø225) (28 Sheds) 52.83 (1342) Ø9.06 (Ø230) UNIT 2 UNIT 2 SJ915EJ Total Weight: 234 231 (5944) (5867) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1000 25000 90000 75000 (4448) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1410 525 1300 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) 18° Ø9.06 (Ø230) 10° 1.77 (45) Ø6.3 (Ø160) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 4xM16 Bolts 4xM16 Nuts 4xB16 Washers DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) R 0.19 (5) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Galvanized Steel: NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.46 (Ø215) Ø10.43 (Ø265) SJ905PJ Assembly: Fixation: Weight: Top / Bottom 166 lb 4 holes 5/8-11UNC 75 kg 4xØ18xØ225 201 lb 4xØ18xØ225 91 kg 4 holes 5/8-11UNC 367 lb 166 kg 18° 1.53 (39) UNIT 1 UNIT 1 Unit Shed ID TR324 SC905 TR324 SC915 1.57 (40) 1.77 (45) Shed Profile (Unit 1) 10° Shed Profile (Unit 2) Bottom Flange View DWG. No.: H21324EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 324 U EUROPE BIL 1300 kV 324SU1300 in (mm) TITLE STATION POST INSULATOR. STANDARD STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.3 (Ø160) Unit Part n° CERISOL EUROPE Year-month Serial number 324SU1300 TR324 SC915 (28 Sheds) 53.15 (1350) Ø9.06 (Ø230) UNIT 1 Ø10.43 (Ø265) Ø8.86 (Ø225) (28 Sheds) 52.83 (1342) Ø9.06 (Ø230) UNIT 2 SW915EJ UNIT 2 SJ915EJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 201 lb 4 holes 5/8-11UNC 91 kg 4xØ18xØ225 201 lb 4xØ18xØ225 91 kg 4 holes 5/8-11UNC 367 lb 166 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 106.0 ±0.16 (2692 ±4) Ø9.06 (Ø230) UNIT 1 Unit Shed ID TR324 SC915 TR324 SC915 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 238 231 (6045) (5867) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1000 1000 25000 90000 75000 (4448) (4448) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1410 525 1300 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) 18° 1.53 (39) Ø9.06 (Ø230) Ø6.3 (Ø160) 10° 1.57 (40) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Shed Profile Bottom Flange View DWG. No.: H21325EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 330 U EUROPE BIL 1470 kV 330SU1470 in (mm) TITLE STATION POST INSULATOR. STANDARD STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.3 (Ø160) Unit Part n° CERISOL EUROPE Year-month Serial number 330SU1470 TR330 SC916 (27 Sheds) 61.0 (1549.5) Ø9.53 (Ø242) UNIT 1 128.0 ±0.19 (3099 ±4.8) Ø8.86 (Ø225) (27 Sheds) 61.0 (1549.5) Ø9.53 (Ø242) UNIT 2 SM916PJ UNIT 2 SN916PJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 230 lb 4 holes 5/8-11UNC 104 kg 4xØ18xØ225 230 lb 4xØ18xØ225 104 kg 4 holes 5/8-11UNC 460 lb 208 kg Galvanized Steel: 4xM16 Bolts 4xM16 Nuts 4x washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø9.53 (Ø242) Ø10.24 (Ø260) UNIT 1 Unit Shed ID TR330 SC916 TR330 SC916 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 267 264 (6782) (6706) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 900 900 25000 90000 75000 (4003) (4003) (111200) (10170) (333600) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1610 590 1470 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) Ø9.53 (Ø242) 1.92 (49) 10° Ø6.3 (Ø160) Ø5.0 (Ø127) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) 1.77 (45) DWG. No.: H21330EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 362 U EUROPE BIL 1050 kV Top Flange View in (mm) TITLE STATION POST INSULATOR. EXTRA HIGH STRENGTH 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) Marks Ø8.66 (Ø220) Unit Part n° CERISOL EUROPE Year-month Serial number 362EU1050 TR362 SC8923 (UNIT1) SC918 (UNIT2) (21 Sheds) 46.0 (1168.5) Ø10.24 (Ø260) UNIT 1 92.0 ±0.13 (2337±3.2) Ø11.42 (Ø290) Ø10.0 (Ø254) (21 Sheds) 46.0 (1168.5) Ø10.43 (Ø265) UNIT 1 UNIT 2 Unit Shed ID TR362 S28923EJ SC8923 TR362 S4918EJ SC918 Total Weight: Assembly: Fixation: Weight: Top / Bottom 256 lb 4 holes 3/4-10UNC 116 kg 8xØ18xØ254 265 lb 8xØ18xØ254 120 kg 4 holes 3/4-10UNC 521 lb 236 kg Galvanized Steel: 8xM16 Bolts 8xM16 Nuts 8x washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø10.24 (Ø260) UNIT 2 362EU1050 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 202 198 (5131) (5030) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 2300 2300 40000 120000 100000 (10230) (10230) (177920) (13560) (444800) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1210 455 1050 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 146 500 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) Ø10.43 (Ø265) 1.69 (43) 10° Ø8.66 (Ø220) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 1.77 (45) DWG. No.: H21362EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 367 EUROPE BIL 1300 kV 367HT1300 in (mm) TITLE STATION POST INSULATOR. HIGH STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.22 (Ø158) Unit Part n° CERISOL EUROPE Year-month Serial number 367HT1300 TR367 SC905 (Unit 1) SC902 (Unit 2) (25 Sheds) 53.15 (1350) Ø8.46 (Ø215) 106.0 ±0.16 (2692 ±4) Ø10.0 (Ø254) (28 Sheds) 52.83 (1342) Ø10.04 (Ø255) UNIT 2 UNIT 2 SJ902MJ Total Weight: 234 231 (5944) (5867) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1450 20000 40000 60000 (6450) (88960) (4250) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1410 525 1300 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) 18° Ø10.04 (Ø255) 10° 1.77 (45) Ø8.66 (Ø220) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 8xM16 Bolts 8xM16 Nuts 8x Washers DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) R 0.19 (5) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) Galvanized Steel: NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.46 (Ø215) Ø11.42 (Ø290) SJ905MJ Assembly: Fixation: Weight: Top / Bottom 166 lb 4 holes 5/8-11UNC 75 kg 8xØ18xØ254 285 lb 8xØ18xØ254 129 kg 4 holes 3/4-10UNC 451 lb 204 kg 18° 1.53 (39) UNIT 1 UNIT 1 Unit Shed ID TR367 SC905 TR367 SC902 1.57 (40) 1.77 (45) Shed Profile (Unit 1) 10° Shed Profile (Unit 2) Bottom Flange View DWG. No.: H21367EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 368 EUROPE BIL 1300 kV in (mm) TITLE 368EU1300 STATION POST INSULATOR. EXTRA HIGH STRENGTH Top Flange View 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) Marks Ø8.66 (Ø220) Unit Part n° CERISOL EUROPE Year-month Serial number 368EU1300 TR368 SC8922 (Unit 1) SC903 (Unit 2) (28 Sheds) 53.15 (1350) Ø10.04 (Ø255) UNIT 1 Ø11.42 (Ø290) Ø10.0 (Ø254) (27 Sheds) 52.83 (1342) Ø10.43 (Ø265) UNIT 2 UNIT 2 Total Weight: Assembly: Fixation: Weight: Top / Bottom 296 lb 4 holes 3/4-10UNC 134 kg 8xØ18xØ255 302 lb 8xØ18xØ255 137 kg 4 holes 3/4-10UNC 598 lb 271 kg Galvanized Steel: 8xM16 Bolts 8xM16 Nuts 8x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 106.0 ±0.16 (2692 ±4) Ø10.04 (Ø255) UNIT 1 Unit Shed ID TR368 S28922EJ SC8922 TR368 S2903MJ SC903 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 234 231 (5944) (5867) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 2050 2050 40000 120000 100000 (9118) (9118) (177920) (13560) (444880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1410 525 1300 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) R 0.19 (5) Ø10.43 (Ø265) 1.53 (39) 18° Ø8.66 (Ø220) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 10° 1.57 (40) Bottom Flange View DWG. No.: H21368EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 369 EUROPE BIL 1300 kV in (mm) TITLE 369ET1300 STATION POST INSULATOR. EXTRA HIGH STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.69 (Ø170) Unit Part n° CERISOL EUROPE Year-month Serial number 369ET1300 TR369 SC902 (Unit 1) SC903 (Unit 2) (28 Sheds) 53.15 (1350) Ø10.04 (Ø255) UNIT 1 Ø11.42 (Ø290) Ø10.0 (Ø254) (27 Sheds) 52.83 (1342) Ø10.43 (Ø265) UNIT 2 UNIT 2 Total Weight: Assembly: Fixation: Weight: Top / Bottom 278 lb 4 holes 5/8-11UNC 126 kg 8xØ18xØ254 302 lb 8xØ18xØ254 137 kg 4 holes 3/4-10UNC 580 lb 263 kg Galvanized Steel: 8xM16 Bolts 8xM16 Nuts 8x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 106.0 ±0.16 (2692 ±4) Ø10.04 (Ø255) UNIT 1 Unit Shed ID TR369 S26902EJ SC6902 TR369 S26903EJ SC6903 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 234 231 (5944) (5867) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 2050 20000 40000 60000 (9118) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1410 525 1300 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) R 0.19 (5) Ø10.43 (Ø265) 1.53 (39) 18° Ø8.66 (Ø220) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 10° 1.57 (40) Bottom Flange View DWG. No.: H21369EJ DWG: TYPE SALES Date: 2015/05/28 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 371 EUROPE BIL 1470 kV Top Flange View Ø5.0 (Ø127) TITLE STATION POST INSULATOR. HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø6.22 (Ø158) Unit Part n° CERISOL EUROPE Year-month Serial number 371HT1470 TR371 SC911 (UNIT1) SC919 (UNIT2) (27 Sheds) 61.0 (1549.5) Ø8.78 (Ø223) UNIT 1 128.0 ±0.19 (3099±4.8) Ø10.24 (Ø260) Ø8.86 (Ø225) (28 Sheds) 61.0 (1549.5) Ø9.72 (Ø247) UNIT 1 SL911MJ UNIT 2 S2919EJ Unit Shed ID TR371 SC911 TR371 SC919 Total Weight: Assembly: Fixation: Weight: Top / Bottom 194 lb 4 holes 5/8-11UNC 88 kg 4xØ18xØ225 267 lb 4xØ18xØ225 121 kg 4 holes 3/4-10UNC 461 lb 209 kg 4xM16 Bolts 4xM16 Nuts 4x washers DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 270 264 (6858) (6706) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1170 20000 40000 60000 (5204) (88960) (4520) (266800) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1610 590 1470 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) R 0.19 (5) 18° 1.92 (49) 10° Ø8.66 (Ø220) 18° 1.77 (45) Ø9.72 (Ø247) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) Bottom Flange View Shed Profile (Unit 1) DWG. No.: H21371EJ DWG: TYPE SALES Date: 2015/07/07 10° 1.77 (45) 1.77 (45) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Galvanized Steel: NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø8.78 (Ø223) UNIT 2 371HT1470 in (mm) Shed Profile (Unit 2) DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 372 EUROPE BIL 1470 kV Top Flange View in (mm) TITLE STATION POST INSULATOR. EXTRA HIGH STRENGTH 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) Marks Ø8.66 (Ø220) Unit Part n° CERISOL EUROPE Year-month Serial number 372EU1470 TR372 SC921 (UNIT1) SC920 (UNIT2) (28 Sheds) 61.0 (1549.5) Ø10.24 (Ø260) UNIT 1 128.0 ±0.19 (3099±4.8) Ø11.42 (Ø290) Ø10.0 (Ø254) (28 Sheds) 61.0 (1549.5) Ø10.32 (Ø262) UNIT 1 UNIT 2 Unit Shed ID TR372 S28921EJ SC921 TR372 S2920MJ SC920 Total Weight: Assembly: Fixation: Weight: Top / Bottom 322 lb 4 holes 3/4-10UNC 146 kg 8xØ18xØ254 309 lb 8xØ18xØ254 140 kg 4 holes 3/4-10UNC 631 lb 286 kg Galvanized Steel: 8xM16 Bolts 8xM16 Nuts 4x washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø10.0 (Ø254) UNIT 2 372EU1470 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 271 264 (6883) (6706) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) CANTILEVER BREAKING STRENGTH,UNDERHUNG pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1750 1750 20000 40000 60000 (7784) (7784) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1610 590 1470 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. Shed Profile (Unit 1,2) 18° R 0.19 (5) 1.92 (49) 10° Ø8.66 (Ø220) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View 1.77 (45) DWG. No.: H21372EJ DWG: TYPE SALES Date: 2015/07/07 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 373 EUROPE BIL 1470 kV Top Flange View Ø5.0 (Ø127) TITLE STATION POST INSULATOR. EXTRA HIGH STRENGTH 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Marks Ø6.3 (Ø160) Unit Part n° CERISOL EUROPE Year-month Serial number 373ET1470 TR373 SC916 (UNIT1) SC920 (UNIT2) (27 Sheds) 61.0 (1549.5) Ø9.53 (Ø242) UNIT 1 128.0 ±0.19 (3099±4.8) Ø11.42 (Ø290) Ø10.0 (Ø254) (28 Sheds) 61.0 (1549.5) Ø10.32 (Ø262) UNIT 1 SP916PJ UNIT 2 S2920EJ Unit Shed ID TR373 SC916 TR373 SC920 Total Weight: Assembly: Fixation: Weight: Top / Bottom 234 lb 4 holes 5/8-11UNC 106 kg 8xØ18xØ254 309 lb 8xØ18xØ254 140 kg 4 holes 3/4-10UNC 543 lb 246 kg Galvanized Steel: 8xM16 Bolts 8xM16 Nuts 4x washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø9.53 (Ø242) UNIT 2 373ET1470 in (mm) DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 269 264 (6833) (6706) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1750 20000 40000 60000 (7784) (88960) (4520) (266800) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1610 590 1470 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 220 1000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) R 0.19 (5) 18° Ø8.66 (Ø220) 1.77 (45) 1.92 (49) 10° 18° 1.77 (45) 1.77 (45) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER Bottom Flange View Shed Profile (Unit 1) DWG. No.: H21373EJ DWG: TYPE SALES Date: 2015/07/07 10° Shed Profile (Unit 2) DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: PART NUMBER CERISOL TR 379 EUROPE BIL 1550 kV 379HT1550 in (mm) TITLE STATION POST INSULATOR. HIGH STRENGTH Top Flange View 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks Ø6.3 (Ø160) Unit Part n° CERISOL EUROPE Year-month Serial number 379HT1550 TR379 SC916 (Unit 1) SC917 (Unit 2) (27 Sheds) 64.0 (1625.5) Ø9.53 (Ø242) UNIT 1 Ø11.42 (Ø290) Ø10.0 (Ø254) (31 Sheds) 64.0 (1625.5) Ø10.32 (Ø262) UNIT 2 SL916MJ UNIT 2 S2917EJ Total Weight: Assembly: Fixation: Weight: Top / Bottom 230 lb 4 holes 5/8-11UNC 104 kg 8xØ18xØ254 329 lb 8xØ18xØ254 149 kg 4 holes 3/4-10UNC 559 lb 253 kg Galvanized Steel: 8xM16 Bolts 8xM16 Nuts 8x Washers NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 128.0 ±0.19 (3251 ±4.8) Ø9.53 (Ø242) UNIT 1 Unit Shed ID TR379 SC916 TR379 SC917 DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) 284 280 (7214) (7112) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1700 20000 40000 60000 (7562) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 1710 620 1550 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 318 2000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) R 0.19 (5) 18° 1.92 (49) Ø8.66 (Ø220) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) Ø7.0 (Ø178) NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 10° 18° 1.69 (43) Ø10.83 (Ø275) 1.77 (45) 1.77 (45) Shed Profile (Unit 1) 10° Shed Profile (Unit 2) Bottom Flange View DWG. No.: H21379EJ DWG: TYPE SALES Date: 2015/07/01 DWN: A.MEJÍA A. APP: C. JARAMILLO Technical reference number: TR 391 EUROPE BIL 1800 kV in (mm) TITLE 391ST1800 STATION POST INSULATOR. STANDARD STRENGTH "T" Top Flange View "T" Ø10.43 (Ø265) 4 Tapped Holes 5/8-11 UNC +0.015 Oversize Full Thread 0.87 (22) Ø5.0 (Ø127) Marks (23 Sheds) 50.67 (1287.0) UNIT 1 Ø10.43 (Ø265) Ø11.42 (Ø290) EUROPE Year-month Serial number 391ST1800 TR391 SC6900 (Unit 1,2) SC6901 (Unit 3) Ø10.0 (Ø254) (22 Sheds) 50.67 (1287) Ø10.83 (Ø275) UNIT 3 152.0 ±0.22 (3861 ±5.6) (23 Sheds) 50.67 (1287) Ø11.42 (Ø290) UNIT 2 UNIT 3 Assembly: Fixation: Top / Bottom 267 lb 4 holes 5/8-11UNC 121 kg 8xØ18xØ254 274 lb 8xØ18xØ254 124 kg 8xØ18xØ254 291 lb 8xØ18xØ254 132 kg 4 holes 3/4-10UNC 832 lb 377 kg Weight: NOT E: TO PURCHASER ALL SALES OF GAMMA PRODUCTS ARE SUBJECT TO OUR STANDARD TERMS AND CONDITIONS AND THE LIMITED WARRANTIES THEREUNDER 330 321.5 (8382) (8166) MECHANICAL VALUES CANTILEVER BREAKING STRENGTH,UPRIGHT pounds (N) TENSILE BREAKING STRENGTH, pounds (N) TORSIONAL BREAKING STRENGTH, in-pounds (N.m) COMPRESSION BREAKING STRENGTH, pounds (N) 1400 20000 40000 60000 (6227) (88960) (4520) (266880) ELECTRICAL VALUES GUARANTEED VOLTAGES: CRITICAL IMPULSE FLASHOVER, POS., kV LOW FREQUENCY WET WITHSTAND, kV IMPULSE WITHSTAND, kV 2000 710 1800 RADIO INFLUENCE VOLTAGE TEST VOLTAGE, RMS TO GROUND, kV MAXIMUM RIV AT 1 MHz, µV 318 2000 Other characteristics: Insulating material: Glaze: Al. Porcelain Light Gray Munsell n° 70 Metal parts assembled with Portland cement. Bolts required for stack assembly are supplied. R 0.19 (5) 18° Bottom Flange View "B" Ø7.0 (Ø178) 4 Tapped Holes 3/4-10 UNC +0.015 Oversize Full Thread 0.87 (22) "B" 16xM16 Bolts 16xM16 Nuts 16x Washers DIMENSIONS NOMINAL LEAKAGE DISTANCE, In (mm) MINIMUM LEAKAGE DISTANCE; In (mm) Ø10.83 (Ø275) Ø8.66 (Ø220) Galvanized Steel: NOTES 1. DIMENSIONS ARE INCHES (MILLIMETERS) 2. ALL FERROUS PARTS ARE HOT DIP GALVANIZED PER ASTM A153, MALLEABLE OR SPHEROIDAL CAST IRON. 3. MEETS CHARACTERISTICS AND TOLERANCES OF ANSI C29.9 / C29.1 Ø10.43 (Ø265) Ø10.43 (Ø265) UNIT 1 Total Weight: Ø10.0 (Ø254) UNIT 2 Unit Shed ID TR391 S26900EJ SC6900 TR391 S36900EJ SC6900 TR391 S26901EJ SC6901 Unit Part n° CERISOL DWG. No.: H21391EJ DWG: TYPE SALES Date: 2015/07/01 1.77 (45) Ø6.69 (Ø170) PART NUMBER CERISOL 10° 1.77 (45) Shed Profile (Unit 1,2,3) DWN: A.MEJÍA A. APP: C. JARAMILLO Date: March 08, 2008 CERTIFICATE OF TESTING MATERIAL TESTED: GAMMA STATION POST Insulator. TR 202 DESIGN TESTS 1. LOW FREQUENCY WET WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.5 of ANSI C29.1-1982. Failure of any insulator to meet the rated wet withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 30 Low Frequency Wet Withstand, kV Unit 2 30 Unit 3 30 Rating 30 Result: Satisfactory 2. CRITICAL IMPULSE FLASHOVER, POSITIVE Three insulators were randomly selected and tested in accordance with section 4.7 of ANSI C29.1-1982. Failure of the average critical – impulse flashover value of the three insulators to equal or exceed 92 percent of the rated critical – impulse flashover value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Critical Impulse Flashover, Positive, kV Unit 1 120,7 Unit 2 119,6 Unit 3 120,9 Average Rating 120,4 105 92% 96.6 Result: Satisfactory 3. IMPULSE WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.8 of ANSI C29.1-1982. Failure of any insulator to meet the rated impulse withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 95 Impulse Withstand, kV Unit 2 95 Unit 3 95 Rating 95 Result: Satisfactory 4. RADIO INFLUENCE VOLTAGE RIV Three insulators were randomly selected and tested in accordance with section 4.9 of ANSI C29.1-1982. If one or more insulators fail to meet the requirements given in the standard, three additional insulators shall be selected at random and tested. Failure of one or more of these additional insulators shall constitute failure to meet the requirements of this standard. RIV at 5 kV, to ground (μV) Result: Satisfactory . Unit 1 Unit 2 <2,5V <2,5V Unit 3 <2,5V Rating max 50 V 5. THERMAL SHOCK TEST Three insulators were randomly selected and tested for ten complete cycles in accordance with section 5.5 of ANSI C29.1-1982. The temperature of the hot water bath was approximately 150°F (66°C) and the temperature of the cold water was approximately 39°F (4°C). At the end of the tenth cycle the test specimens were checked for electrical soundness. If one insulator fails, three additional insulators shall be selected randomly and tested. Failure of more than one insulator from the first set of samples, or from the first and second set of samples combined shall constitute failure to meet the requirements of this standard. Three insulators were thermal shock tested in accordance to ANSI Standard, section 5.5. All units passed this test. Result: Satisfactory 6. COMPRESSION STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.4 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement where applicable, or failure of any one insulator unit to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Compression Strength, pounds (*) Unit 1 Unit 2 225.496 226.202 Unit 3 224.941 Average 225.546 Rating 10.000 85% 8500 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory 7. TORSIONAL STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.2 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Torsional Strength, inches pounds Unit 1 20.116 Unit 2 21.586 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 26.118 Average 22.607 Rating 6.000 85% 5100 QUALITY CONFORMANCE TESTS 1. VISUAL AND DIMENSIONAL TEST Three insulators were randomly selected and checked according to section 4.2 of the standard and met the requirements. Their dimensions were verified against the manufacturing drawing. Failure of more than one of these insulators to conform to the dimensions on the drawing shall constitute failure of the lot to meet the requirements of the standard. All the samples meet the conditions and dimensions. Result: Satisfactory 2. POROSITY TEST Ten samples of porcelain taken from the same firing cycle as these posts were subjected to the porosity test. No porosity was observed. The test was performed in accordance with ANSI C29.9-1983, paragraph 7.3.2. Dyer penetration: NEGATIVE: X POSITIVE: Result: Satisfactory 3. GALVANIZING TEST A galvanizing thickness test was performed on three hardware samples. The galvanizing thickness measured, equaled or exceeded the values given in the table shown in paragraph 7.3.3 of ANSI C29.91983. Result: Satisfactory 4. CANTILEVER STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.1 of ANSI C29.11982. The units were tested individually. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Cantilever Strength, pounds Unit 1 5.985 Unit 2 5.806 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 5.995 Average 5.929 Rating 2000 85% 1700 5. TENSILE STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.3 of ANSI C29.1-1982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Tensile Strength, pounds (*) Unit 1 30.007 Unit 2 27.028 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory FRANK ESCOBAR OBANDO PRODUCT ENGINEER. . Unit 3 27.912 Average 28.316 Rating 7000 85% 5950 Date: March 08, 2008 CERTIFICATE OF TESTING MATERIAL TESTED: GAMMA STATION POST Insulator. TR 205 DESIGN TESTS 1. LOW FREQUENCY WET WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.5 of ANSI C29.1-1982. Failure of any insulator to meet the rated wet withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 45 Low Frequency Wet Withstand, kV Unit 2 45 Unit 3 45 Rating 45 Result: Satisfactory 2. CRITICAL IMPULSE FLASHOVER, POSITIVE Three insulators were randomly selected and tested in accordance with section 4.7 of ANSI C29.1-1982. Failure of the average critical – impulse flashover value of the three insulators to equal or exceed 92 percent of the rated critical – impulse flashover value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Critical Impulse Flashover, Positive, kV Unit 1 150,7 Unit 2 142,1 Unit 3 145,1 Average Rating 146,0 125 92% 115 Result: Satisfactory 3. IMPULSE WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.8 of ANSI C29.1-1982. Failure of any insulator to meet the rated impulse withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 110 Impulse Withstand, kV Unit 2 110 Unit 3 110 Rating 110 Result: Satisfactory 4. RADIO INFLUENCE VOLTAGE RIV Three insulators were randomly selected and tested in accordance with section 4.9 of ANSI C29.1-1982. If one or more insulators fail to meet the requirements given in the standard, three additional insulators shall be selected at random and tested. Failure of one or more of these additional insulators shall constitute failure to meet the requirements of this standard. RIV at 10 kV, to ground (μV) Unit 1 <2,5V Result: Satisfactory . Unit 2 <2,5V Unit 3 <2,5V Rating 50 V max 5. THERMAL SHOCK TEST Three insulators were randomly selected and tested for ten complete cycles in accordance with section 5.5 of ANSI C29.1-1982. The temperature of the hot water bath was approximately 150°F (66°C) and the temperature of the cold water was approximately 39°F (4°C). At the end of the tenth cycle the test specimens were checked for electrical soundness. If one insulator fails, three additional insulators shall be selected randomly and tested. Failure of more than one insulator from the first set of samples, or from the first and second set of samples combined shall constitute failure to meet the requirements of this standard. Three insulators were thermal shock tested in accordance to ANSI Standard, section 5.5. All units passed this test. Result: Satisfactory 6. COMPRESSION STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.4 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement where applicable, or failure of any one insulator unit to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Compression Strength, pounds (*) Unit 1 Unit 2 225.406 226.056 Unit 3 224.770 Average 225.411 Rating 10.000 85% 8500 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory 7. TORSIONAL STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.2 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Torsional Strength, inches pounds Unit 1 19.418 Unit 2 20.716 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 21.529 Average 20.554 Rating 7.000 85% 5950 QUALITY CONFORMANCE TESTS 1. VISUAL AND DIMENSIONAL TEST Three insulators were randomly selected and checked according to section 4.2 of the standard and met the requirements. Their dimensions were verified against the manufacturing drawing. Failure of more than one of these insulators to conform to the dimensions on the drawing shall constitute failure of the lot to meet the requirements of the standard. All the samples meet the conditions and dimensions. Result: Satisfactory 2. POROSITY TEST Ten samples of porcelain taken from the same firing cycle as these posts were subjected to a porosity test. No porosity was observed. The test was performed in accordance with ANSI C29.9-1983, paragraph 7.3.2. Dyer penetration: NEGATIVE: X POSITIVE: Result: Satisfactory 3. GALVANIZING TEST A galvanizing thickness test was performed on three hardware samples. The galvanizing thickness measured, equaled or exceeded the values given in the table shown in paragraph 7.3.3 of ANSI C29.91983. Result: Satisfactory 4. CANTILEVER STRENGTH TEST Three insulators were randomly selected and tested according to section 5.1.4.1 of ANSI C29.1-1982. The units were tested individually. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Cantilever Strength, pounds Unit 1 4.239 Unit 2 4.781 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 4.162 Average 4.394 Rating 2000 85% 1700 5. TENSILE STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.3 of ANSI C29.1-1982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard Tensile Strength, pounds (*) Unit 1 23.692 Unit 2 25.763 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory FRANK ESCOBAR OBANDO PRODUCT ENGINEER. . Unit 3 26.058 Average 25.171 Rating 8500 85% 7225 Date: March 08, 2008 CERTIFICATE OF TESTING MATERIAL TESTED: GAMMA STATION POST Insulator TR 208 DESIGN TESTS 1. LOW FREQUENCY WET WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.5 of ANSI C29.1-1982. Failure of any insulator to meet the rated wet withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 60 Low Frequency Wet Withstand, kV Unit 2 60 Unit 3 60 Rating 60 Result: Satisfactory 2. CRITICAL IMPULSE FLASHOVER, POSITIVE Three insulators were randomly selected and tested in accordance with section 4.7 of ANSI C29.1-1982. Failure of the average critical – impulse flashover value of the three insulators to equal or exceed 92 percent of the rated critical – impulse flashover value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Critical Impulse Flashover, Positive, kV Unit 1 171,9 Unit 2 174,4 Unit 3 175,5 Average Rating 173,9 170 92% 156.4 Result: Satisfactory 3. IMPULSE WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.8 of ANSI C29.1-1982. Failure of any insulator to meet the rated impulse withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 151 Impulse Withstand, kV Unit 2 150 Unit 3 151 Rating 150 Result: Satisfactory 4. RADIO INFLUENCE VOLTAGE RIV Three insulators were randomly selected and tested in accordance with section 4.9 of ANSI C29.1-1982. If one or more insulators fail to meet the requirements given in the standard, three additional insulators shall be selected at random and tested. Failure of one or more of these additional insulators shall constitute failure to meet the requirements of this standard. Unit 1 <2,5V RIV at 15 kV, to ground (μV) Result: Satisfactory . Unit 2 <2,5V Unit 3 <2,5V Rating 100 V max 5. THERMAL SHOCK TEST Three insulators were randomly selected and tested for ten complete cycles in accordance with section 5.5 of ANSI C29.1-1982. The temperature of the hot water bath was approximately 150°F (66°C) and the temperature of the cold water was approximately 39°F (4°C). At the end of the tenth cycle the test specimens were checked for electrical soundness. If one insulator fails, three additional insulators shall be selected randomly and tested. Failure of more than one insulator from the first set of samples, or from the first and second set of samples combined shall constitute failure to meet the requirements of this standard. Three insulators were thermal shock tested in accordance to ANSI Standard, section 5.5. All units passed this test. Result: Satisfactory 6. COMPRESSION STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.4 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement where applicable, or failure of any one insulator unit to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Compression Strength, pounds (*) Unit 1 Unit 2 225.480 225.570 Unit 3 225.795 Average 225.615 Rating 10000 85% 8500 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory 7. TORSIONAL STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.2 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Torsional Strength, inches pounds Unit 1 21.232 Unit 2 24.023 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 25.311 Average 23.522 Rating 8000 85% 6800 QUALITY CONFORMANCE TESTS 1. VISUAL AND DIMENSIONAL TEST Three insulators were randomly selected and checked according to section 4.2 of the standard and met the requirements. Their dimensions were checked against the dimension of manufacturing drawing Failure of more than one of these insulators to conform to the dimensions of the drawing shall constitute failure of the lot to meet the requirements of the standard. All the samples meet the conditions and dimensions. Result satisfactory. Result: Satisfactory 2. POROSITY TEST Ten samples of porcelain taken from the same firing cycle as these posts were subjected to a porosity test. No porosity was observed. The test was performed in accordance with ANSI C29.9-1983, paragraph 7.3.2. Dyer penetration: NEGATIVE: X POSITIVE: Result: Satisfactory 3. GALVANIZING TEST A galvanizing thickness test was performed on three hardware samples. The galvanizing thickness measured, equaled or exceeded the values given in the table shown in paragraph 7.3.3 of ANSI C29.91983. Result: Satisfactory 4. CANTILEVER STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.1 of ANSI C29.11982. The units were tested individually. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Cantilever Strength, pounds Unit 1 3.226 Unit 2 2.641 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 2.689 Average 2.852 Rating 2000 85% 1700 5. TENSILE STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.3 of ANSI C29.1-1982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Tensile Strength, pounds (*) Unit 1 18.985 Unit 2 22.672 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory FRANK ESCOBAR OBANDO PRODUCT ENGINEER. . Unit 3 26.324 Average 22.660 Rating 10000 85% 8500 Date: March 08, 2008 CERTIFICATE OF TESTING MATERIAL TESTED: GAMMA STATION POST Insulator. TR 210 DESIGN TESTS 1. LOW FREQUENCY WET WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.5 of ANSI C29.1-1982. Failure of any insulator to meet the rated wet withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 80 Low Frequency Wet Withstand, kV Unit 2 80 Unit 3 80 Rating 80 Result: Satisfactory 2. CRITICAL IMPULSE FLASHOVER, POSITIVE Three insulators were randomly selected and tested in accordance with section 4.7 of ANSI C29.1-1982. Failure of the average critical – impulse flashover value of the three insulators to equal or exceed 92 percent of the rated critical – impulse flashover value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Critical Impulse Flashover, Positive, kV Unit 1 208,1 Unit 2 211,7 Unit 3 212 Average Rating 210,6 225 92% 207 Result: Satisfactory 3. IMPULSE WITHSTAND Three insulators were randomly selected and tested in accordance with section 4.8 of ANSI C29.1-1982. Failure of any insulator to meet the rated impulse withstand value, as given in the applicable table, shall constitute failure to meet the requirements of the standard. Unit 1 201,21 Impulse Withstand, kV Unit 2 203,53 Unit 3 200,09 Rating 200 Result: Satisfactory 4. RADIO INFLUENCE VOLTAGE RIV Three insulators were randomly selected and tested in accordance with section 4.9 of ANSI C29.1-1982. If one or more insulators fail to meet the requirements given in the standard, three additional insulators shall be selected at random and tested. Failure of one or more of these additional insulators shall constitute failure to meet the requirements of this standard. Unit 1 < 2,5V RIV at 22 kV, to ground (μV) Result: Satisfactory . Unit 2 < 2,5V Unit 3 < 2,5V Rating 100 V max 5. THERMAL SHOCK TEST Three insulators were randomly selected and tested for ten complete cycles in accordance with section 5.5 of ANSI C29.1-1982. The temperature of the hot water bath was approximately 150°F (66°C) and the temperature of the cold water was approximately 39°F (4°C). At the end of the tenth cycle the test specimens were checked for electrical soundness. If one insulator fails, three additional insulators shall be selected randomly and tested. Failure of more than one insulator from the first set of samples, or from the first and second set of samples combined shall constitute failure to meet the requirements of this standard. Three insulators were thermal shock tested in accordance to ANSI Standard, section 5.5. All units passed this test. Result: Satisfactory 6. COMPRESSION STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.4 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement where applicable, or failure of any one insulator unit to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard Compression Strength, pounds (*) Unit 1 Unit 2 140.757 131.166 Unit 3 215.206 Average 162.376 Rating 15000 85% 12750 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory 7. TORSIONAL STRENGTH Three insulators were randomly selected and tested in accordance with section 5.1.4.2 of ANSI C29.11982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard Torsional Strength, inches pounds Unit 1 25.866 Unit 2 25.799 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 25.773 Average 25.813 Rating 10000 85% 8500 QUALITY CONFORMANCE TESTS 1. VISUAL AND DIMENSIONAL TEST Three insulators were randomly selected and checked according to section 4.2 of the standard and met the requirements. Their dimensions were checked against the dimension of manufacturing drawing Failure of more than one of these insulators to conform to the dimensions of the drawing shall constitute failure of the lot to meet the requirements of the standard. All the samples meet the conditions and dimensions. Result satisfactory. Result: Satisfactory 2. POROSITY TEST Ten samples of porcelain taken from the same firing cycle as these posts were subjected to a porosity test. No porosity was observed. The test was performed in accordance with ANSI C29.9-1983, paragraph 7.3.2. Dyer penetration: NEGATIVE: X POSITIVE: Result: Satisfactory 3. GALVANIZING TEST A galvanizing thickness test was performed on three hardware samples. The galvanizing thickness measured, equaled or exceeded the values given in the table shown in paragraph 7.3.3 of ANSI C29.91983. Result: Satisfactory 4. CANTILEVER STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.1 of ANSI C29.11982. The units were tested individually. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Cantilever Strength, pounds Unit 1 3.628 Unit 2 3.791 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory . Unit 3 3.693 Average 3.704 Rating 2000 85% 1700 5. TENSILE STRENGTH TEST Three insulators were randomly selected and tested in accordance with section 5.1.4.3 of ANSI C29.1-1982. Failure of the average strength of the three insulators to meet the strength requirements given in the tables or to meet the specified higher strength requirement, where applicable, or failure of any insulator to equal 85% of that strength requirement shall constitute failure to meet the requirements of this standard. Tensile Strength, pounds (*) Unit 1 40.000 Unit 2 40.000 NOTE: (*) Load released with no visible damage to the unit Result: Satisfactory FRANK ESCOBAR OBANDO PRODUCT ENGINEER. . Unit 3 40.000 Average 40.000 Rating 12000 85% 10200 Design Test Certification Material Tested GAMMA Catalog Number 8435 TEST OBJECT: Station Post Insulator TYPE SPECIFICATION: TR 214 TEST STANDARDS: ANSI C29.9, ANSI C29.1, NEMA No. 107:1993 SCHEDULE OF TESTS Design Tests, Section 7.2 Page Test Section Description of Test Electrical Tests 2 7.2.1 Low-frequency Wet Withstand Voltage 3 7.2.2 & 7.2.3 Critical Impulse Flashover Positive & Impulse Withstand Voltage 5 7.2.4 Radio-influence voltage tests Mechanical Tests 6 7.2.5 Thermal shock test 7 7.2.6 Compression Strength 8 7.2.7 Torsional Strength Quality Conformance Tests, Section 7.3 9 7.3.4 Cantilever Strength 10 7.3.5 Tensile Strength All Electrical tests were performed per the requirements of ANSI test standard C29.9:2012, ANSI C29.1:2012, and NEMA No. 107:1993. All Mechanical tests were performed per the requirements of ANSI test standard C29.9 - 1983 (R1996), and ANSI C29.1 – 1988 (R2002). Page 1 of 5 GAMMA Catalog 8435 Design Test Certification 7.2.1 Low-frequency Wet Withstand Voltage The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.1. The rated wet withstand voltage was applied on each of the tested post insulator for 10 seconds. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Low-frequency Wet Withstand Voltage Test Results Sample No. 1 Sample No. 2 Sample No. 3 b (in Hg) t (°F) 29.42 65.84 29.42 65.84 29.42 65.84 r.i. (mm/min) RW (Ωm) VLW (kV) T (s) result 5.0 185.0 5.0 185.0 5.0 185.0 100 10 no flashover occurred 100 10 no flashover occurred 100 10 no flashover occurred No flashover occurred during the test at the rated wet withstand voltage 100 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Post type insulator TR-214, Catalog No. 8435 passed low-frequency wet withstand voltage test according to ANSI C29.9, cl. 7.2.1. 7.2.2 & 7.2.3 Impulse Withstand Voltage Test and Flashover Voltage The tests were carried out on the three post insulators according to ANSI C29.9, cl. 7.2.2 and 7.2.3. Three consecutive impulses of the rated impulse-withstand value of both polarities were applied on each of tested post insulator. The critical impulse voltages of both polarities were determined by the up and down method with 30 impulses. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Impulse Withstand Voltage and Flashover Voltage Test Results Polarity Test Sample No. VIW (kV) Impulses Flashovers b (in Hg) t (°F) Kh Kd VCRS LI (kV) VCRSA LI (kV) + - 1 2 3 1 2 3 250 3 0 29.48 67.6 250 3 0 29.48 67.6 250 3 0 29.48 67.6 250 3 0 29.48 67.6 250 3 0 29.48 67.6 250 3 0 29.48 67.6 1.0029 1.0764 1.0029 1.0764 1.0029 1.0764 1.0029 1.0663 1.0029 1.0663 1.0029 1.0663 277 277 276 468 452 482 277 467 No flashover occurred during the test with three impulses at the rated impulse-withstand voltage 250 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Post type insulator TR-214, C a t a l o g No. 8435 passed impulse withstand voltage test according to ANSI C29.9, cl. 7.2.3. The rated critical-impulse flashover voltage 280 kV is specified by ANSI C29.9, Table 2. The average values of critical-impulse flashover voltages are higher than 92 percent of the rated critical-impulse flashover voltage, i.e. 258 kV. All test samples met the requirements. Post type insulator TR-214, Catalog No. 843 passed critical-impulse flashover voltage test according to ANSI C29.9, cl. 7.2.2. Page 2 of 5 GAMMA Catalog 8435 Design Test Certification 7.2.4 Radio-influence Voltage (RIV) Test The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.4. Radio-influence voltage was measured at the frequency 1.0 MHz in accordance with circuit diagram in Figure 3 – 3a of NEMA No. 107, Section 3. The test arrangement was set up according to ANSI C29.1, cl. 4.9.1. Radio-influence Voltage (RIV) Test Results Sample No. 1 b (in Hg) t (°F) Sample No. 2 29,48 63,5 RIV (µV) 4 4 4 4 VT (kV) 33 30 27 0 Sample No. 3 29,48 63,5 29,48 63,5 RIV (µV) 4 4 4 4 RIV (µV) 4 4 4 4 Rated value: max. 200 µV at 30 kV/1,0 MHz Measured values of radio-influence voltages on post insulators at test voltage 30 kV (1 MHz) are less than 200 µV specified by ANSI C29.9, Table 2. All test samples met the requirements. Post type insulator TR-214, Catalog No. 8435 passed radioinfluence voltage test according to ANSI C29.9, cl. 7.2.4. 7.2.5 Thermal Shock Test The test was carried out on three post insulator according to ANSI C 29.9, cl 7.2.5. Each tested post insulator was first immersed in a hot water bath 150 °F (66 °C) for 10 minutes. Then it was withdrawn and immersed in a cold water bath 39 °F (4 °C) for 10 minutes. After tenth cycle each post insulator was tested for electrical soundness by low-frequency momentary flashover voltage test. Thermal Shock Test Results 10 cycles (150 °F / 10 min and 39 °F/ 10 min) Low-frequency Momentary Flashover Voltage Test Flashover voltage (kV) Result Test Sample No. 1 No failure No failure 173 Passed Test Sample No. 2 No failure No failure 178 Passed Test Sample No. 3 No failure No failure 179 Passed No failure occurred during the thermal shock test according to ANSI C29.9, cl. 7.2.5. All test samples met the requirements. Post type insulator TR-214, Catalog No. 8435 passed thermal shock test according to ANSI C29.9, cl. 7.2.5. Page 3 of 5 GAMMA Catalog 8435 Design Test Certification 7.2.6 Compression Strength Test Temperature 68 -71.6 °F (20-22 °C), Minimum failing load 14,994.76 lbs. (66.70 kN). Smooth increase in load 450 - 900 lbs. /s. (2 - 4 kN/s), smooth load up to failure, visual inspection Compression Strength Test Results Sample No. Maximum failure load lbs. (kN) Failure Mode 7 (3012) Sheds Passed 8 (2035) Sheds Passed 9 (3012) Ceramic core Passed Average Result (MFL) (2686) 7.2.7 Torsional Strength Test Temperature during test + 73.4 °F (+ 23 °C), Minimum failing load (MFL) 11,948.51 lb.-in. (1.35 kNm), Smooth increase in load 265.52- 442.54 lb.-in./s (0.03 – 0.05 kNm/s), Smooth load up to failure of screws Torsional Strength Test Results Sample No. Maximum reached torsional moment lbs. (kNm) 10 >75,231.34 (8.5) 11 > 77,001.49 (8.7) 12 > 57,529.85 (6.5) Failure Mode Screws failed. Insulator did not fail. Test stopped by operator. Screws failed. Insulator did not fail. Test stopped by operator. Insulator did not fail. Test stopped by operator Result (MFL) Passed Passed Passed 7.3.4 Cantilever Strength Test Temperature during test + 71.6 °F (+ 22 °C), Minimum failing load (MFL) 2,023.28 lbs. (9 kN), Increase in load 6.74 – 13.49 lbs. /s (0.03 - 0.06 kN/s), smoothly to failure Cantilever Strength Test Results Sample No. Maximum failing load lbs. (kN) 1 3,214.77 (14.30) Failed at bottom part of ceramic core passed 2 2,203.13 (9.80) Failed at bottom part of ceramic core passed 3 3,012.44 (13.4) Failed at bottom part of ceramic core passed Average 2,810.11 (12.5) Page 4 of 5 Failure Mode Result (MFL) GAMMA Catalog 8435 Design Test Certification 7.3.5 Tensile strength Temperature 68 – 69.8 °F (20-21 °C), Minimum failing load (MFL) 13,983.11 lbs. (62.2 kN), Increase in load 6.74 – 13.49 lbs./s (0.3 – 0.6 kN/s), smoothly. Smooth load up to failure, visual inspection Tensile Strength Test Results Sample No. Maximum failure load [kN] 4 20,839.79 (92.7) Ceramic core inside of metal cap Passed 5 36,081.84 (160.5) Ceramic core inside of metal cap Passed 6 28,404.61 (126.35) Ceramic core inside of metal cap Passed Average 28,438.33 (126.5) Way of failure Result (MFL) Tests performed at EGU HV Laboratory a. s., Test No. 10210/A/15, and The Klockner Institute, Report No. 129/15/AL. All test results contained in this document are held on file under drawing number reference 84351011. __________________________________ Frank Escobar Chief Engineer, GAMMA Insulators Corporation Page 5 of 5 Design Test Certification Material Tested GAMMA Catalog Number 8436 TEST OBJECT: Station Post Insulator TYPE SPECIFICATION: TR 216 TEST STANDARDS: ANSI C29.9, ANSI C29.1, NEMA No. 107:1993 SCHEDULE OF TESTS Design Tests, Section 7.2 Page Test Section Description of Test Electrical Tests 2 7.2.1 Low-frequency Wet Withstand Voltage 3 7.2.2 & 7.2.3 Critical Impulse Flashover Positive & Impulse Withstand Voltage 5 7.2.4 Radio-influence voltage tests Mechanical Tests 6 7.2.5 Thermal shock test 7 7.2.6 Compression Strength 8 7.2.7 Torsional Strength Quality Conformance Tests, Section 7.3 9 7.3.4 Cantilever Strength 10 7.3.5 Tensile Strength All Electrical tests were performed per the requirements of ANSI test standard C29.9:2012, ANSI C29.1:2012, and NEMA No. 107:1993. All Mechanical tests were performed per the requirements of ANSI test standard C29.9 - 1983 (R1996), and ANSI C29.1 – 1988 (R2002). Page 1 of 5 GAMMA Catalog 8436 Design Test Certification 7.2.1 Low-frequency Wet Withstand Voltage The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.1. The rated wet withstand voltage was applied on each of the tested post insulator for 10 seconds. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Low-frequency Wet Withstand Voltage Test Results Sample No. 1 b (in Hg) t (°F) r.i. (mm/min) RW (Ωm) VLW (kV) T (s) Result Sample No. 2 Sample No. 3 29.42 67.1 29.42 67.1 29.42 67.1 5.0 185.0 5.0 185.0 5.0 185.0 145 10 no flashover occurred 145 10 no flashover occurred 145 10 no flashover occurred No flashover occurred during the test at the rated wet withstand voltage 145 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Post type insulator TR-216, Catalog No. 8436 passed low-frequency wet withstand voltage test according to ANSI C29.9, cl. 7.2.1. 7.2.2 & 7.2.3 Impulse Withstand Voltage Test and Flashover Voltage The tests were carried out on the three post insulators according to ANSI C29.9, cl. 7.2.2 and 7.2.3. Three consecutive impulses of the rated impulse-withstand value of both polarities were applied on each of tested post insulator. The critical impulse voltages of both polarities were determined by the up and down method with 30 impulses. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Impulse Withstand Voltage and Flashover Voltage Test Results Polarity Test Sample No. VIW (kV) Impulses Flashovers b (in Hg) t (°F) Kh Kd VCRS LI (kV) VCRSA LI (kV) + 1 350 3 0 2 350 3 0 3 350 3 0 1 350 3 0 2 350 3 0 29.48 64.6 29.48 64.6 29.48 64.6 29.48 64.6 1.0088 1.0823 1.0088 1.0823 1.0088 1.0823 1.0088 1.0714 1.0088 1.0714 386 381 630 640 383 383 29.48 64.6 3 350 3 0 29.48 64.6 1.0088 1.0714 617 629 No flashover occurred during the test with three impulses at the rated impulse-withstand voltage 350 kV specified by ANSI C29.9, Table 2, All test samples met the requirements. Post type insulator TR-216, Catalog No. 8436 passed impulse withstand voltage test according to ANSI C29.9, cl. 7.2.3. The rated critical-impulse flashover voltage 390 kV is specified by ANSI C29.9, Table 2. The average values of critical-impulse flashover voltages are higher than 92 percent of the rated critical-impulse flashover voltage, i.e. 359 kV. All test samples met the requirements. Post type insulator TR-216, Catalog No. 8436 passed critical-impulse flashover voltage test according to ANSI C29.9, cl. 7.2.2. Page 2 of 5 GAMMA Catalog 8436 Design Test Certification 7.2.4 Radio-influence Voltage (RIV) Test The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.4. Radio-influence voltage was measured at the frequency 1.0 MHz in accordance with circuit diagram in Figure 3 – 3a of NEMA No. 107, Section 3. The test arrangement was set up according to ANSI C29.1, cl. 4.9.1. Radio-influence Voltage (RIV) Test Results Sample No. 1 Sample No. 2 29.48 63.5 b (in Hg) t (°F) 29.48 63.5 RIV (µV) VT (kV) 48 44 40 36 0 Sample No. 3 29.48 63.5 RIV (µV) 4 4 4 4 4 RIV (µV) 4 4 4 4 4 4 4 4 4 4 Rated value: max. 200 µV at 30 kV/1,0 MHz Measured values of radio-influence voltages on post insulators at test voltage 44 kV (1 MHz) are less than 200 µV specified by ANSI C29.9, Table 2. All test samples met the requirements. Post type insulator TR-216, Catalog No. 8436 passed radioinfluence voltage test according to ANSI C29.9, cl. 7.2.4. 7.2.5 Thermal Shock Test The test was carried out on three post insulator according to ANSI C 29.9, cl 7.2.5. Each tested post insulator was first immersed in a hot water bath 150 °F (66 °C) for 10 minutes. Then it was withdrawn and immersed in a cold water bath 39 F (4 °C) for 10 minutes. After tenth cycle each post insulator was tested for electrical soundness by low-frequency momentary flashover voltage test. Thermal Shock Test Results 10 cycles (150 °F / 10 min and 39 °F/ 10 min) Low-frequency Momentary Flashover Voltage Test Flashover voltage (kV) Result Test Sample No. 1 No failure No failure 242 Passed Test Sample No. 2 No failure No failure 246 Passed Test Sample No. 3 No failure No failure 241 Passed No failure occurred during the thermal shock test according to ANSI C29.9, cl. 7.2.5. All test samples met the requirements. Post type insulator TR-216, Catalog No. 8436 passed thermal shock test according to ANSI C29.9, cl. 7.2.5. Page 3 of 5 GAMMA Catalog 8436 Design Test Certification 7.2.6 Compression Strength Test Temperature 68 -71.6 °F (20-22 °C), Minimum failing load 24,998.75 lbs. (111.2 kN). Smooth increase in load 450 - 900 lbs./s. (2 - 4 kN/s), Smooth load up to failure, visual inspection Compression Strength Test Results Sample No. Maximum failure load lbs. (kN) Failure Mode Result (MFL) 7 (3754) Ceramic core Passed 8 (3628) Ceramic core Passed 9 (3472) Ceramic core Passed Average (3618) 7.2.7 Torsional Strength Test Temperature during test + 73.4 °F (+ 23 °C), Minimum failing load (MFL) 15,002 lb.-in. (1.695 kNm), Smooth increase in load 265.52- 442.54 lb.-in./s (0.03 – 0.05 kNm/s), Smooth load up until 57,530 lb.-in. (6.5 kNm) – The limit of screws used, test stopped by operator, visual inspection. Torsional Strength Test Results Sample No. Maximum Reached Torsional Moment lbs.-in. (kNm) Failure Mode Result (MFL) 10 >57,530 (6.5) Insulator did not fail. Test stopped by operator. Passed 11 >57,530 (6.5) Insulator did not fail. Test stopped by operator Passed 12 >57,530 (6.5) Insulator did not fail. Test stopped by operator Passed 7.3.4 Cantilever Strength Test Temperature during test + 71.6 °F (+ 22 °C), Minimum failing load (MFL) 1,506.22 lbs. (6. kN), Increase in load 6.74 – 13.49 lbs. /s (0.03 - 0.06 kN/s), smoothly until failure Cantilever Strength Test Results Sample No. Maximum failing load lbs. (kN] Failure Mode Result (MFL) 1 2,855.07 (12.7) Failed at bottom part of ceramic core Passed 2 1775.99 (7.9) Failed at bottom part of ceramic core Passed 3 2472.90 (11.0) Failed at bottom part of ceramic core Passed Average 2360.50 (10.5) Page 4 of 5 GAMMA Catalog 8436 Design Test Certification 7.3.5 Tensile strength Temperature 68 – 69.8 °F (20-21 °C), Minimum failing load (MFL) 16,006.40 lbs. (71.2 kN), Increase in load 6.74 – 13.49 lbs./s (0.3 – 0.6 kN/s), smoothly. Smooth load up to Failure, visual inspection. Tensile Strength Test Results Sample No. 4 Maximum failure load lbs. (kN) 25,628.22 (114.0) Failure Mode Result (MFL) Ceramic core inside of metal cap Passed 5 23,649.90 (105.2) Ceramic core inside of metal cap Passed 6 24,661.54 (109.7) Ceramic core inside of metal cap Passed Average 24,639.06 (109.6) Tests performed at EGU HV Laboratory a. s., Test No.10201/B/15, and The Klokner Institute, Report No. 128/15/AL. All test results contained in this document are held on file under drawing number reference 84361011. __________________________________ Frank Escobar Chief Engineer, GAMMA Insulators Corporation Page 5 of 5 Design Test Certification Material Tested GAMMA-CERISOL Catalog Number 288SU0650 TEST OBJECT: Station Post Insulator TYPE SPECIFICATION: TR 288 TEST STANDARDS: ANSI C29.9, ANSI C29.1, NEMA No. 107:1993 SCHEDULE OF TESTS Design Tests, Section 7.2 Page Test Section Description of Test Electrical Tests 2 7.2.1 Low-frequency Wet Withstand Voltage 3 7.2.2 & 7.2.3 Critical Impulse Flashover Positive & Impulse Withstand Voltage 5 7.2.4 Radio-influence voltage tests Mechanical Tests 6 7.2.5 Thermal shock test 7 7.2.6 Compression Strength 8 7.2.7 Torsional Strength Quality Conformance Tests, Section 7.3 9 7.3.4 Cantilever Strength 10 7.3.5 Tensile Strength All Electrical tests were performed per the requirements of ANSI test standard C29.9:2012, ANSI C29.1:2012, and NEMA No. 107:1993. All Mechanical tests were performed per the requirements of ANSI test standard C29.9 - 1983 (R1996), and ANSI C29.1 – 1988 (R2002). Page 1 of 5 GAMMA-CERISOL Catalog 288SU0650 Design Test Certification 7.2.1 Low-frequency Wet Withstand Voltage The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.1. The rated wet withstand voltage was applied on each of the tested post insulator for 10 seconds. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Low-frequency Wet Withstand Voltage Test Results Station post insulator Sample No. 1 Sample No.2 Sample No.3 b (in Hg) 28.88 28.88 28.88 t (°F) 60.6 60.6 60.6 r.i. (mm/min) 5.0 5.0 5.0 Rw (Ωm) 200.0 200.0 200.0 VLW (kV) 275 275 275 T (s) 10 10 10 result No flashover occurred No flashover occurred No flashover occurred No flashover occurred during the test at the rated wet withstand voltage 275 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 288, Catalog No. 288SU0650 passed low-frequency wet withstand voltage tests according to ANSI C29.9, cl. 7.2.1. 7.2.2 & 7.2.3 Impulse Withstand Voltage Test and Flashover Voltage The tests were carried out on the three post insulators according to ANSI C29.9, cl. 7.2.2 and 7.2.3. Three consecutive impulses of the rated impulse-withstand value of both polarities were applied on each of tested post insulator. The critical impulse voltages of both polarities were determined by the up and down method with 30 impulses. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Impulse Withstand Voltage and Flashover Voltage Test Results Polarity Test sample No. VIW (kV) Impulses Flashovers b (in Hg) t (°F) Kh Kd VCRS LI (kV) VCRSA LI (kV) 1 650 3 0 28.85 60.6 1.066 0.995 701 + 2 650 3 0 28.85 60.6 1.066 0.995 711 706 3 650 3 0 28.76 61.7 1.061 0.990 706 1 650 3 0 28.85 60.6 1.058 0.995 863 2 650 3 0 28.85 60.6 1.058 0.995 846 846 3 650 3 0 28.76 61.7 1.054 0.990 829 No flashover occurred during the test with three impulses at the rated impulse-withstand voltage 650 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 288, Catalog No. 288SU0650 passed impulse withstand voltage tests according to ANSI C29.9, cl. 7.2.3. The rated critical-impulse flashover voltage 710 kV is specified by ANSI C29.9, Table 2. The average values of critical-impulse flashover voltages are higher than 92 percent of the rated critical-impulse flashover voltage, i.e. 653 kV. All test samples met Page 2 of 5 the requirements. Station post insulator TR 288, Catalog No. 288SU0650 passed critical impulse flashover voltage tests according to ANSI C29.9, cl. 7.2.2. GAMMA-CERISOL Catalog 288SU0650 Design Test Certification 7.2.4 Radio-influence Voltage (RIV) Test The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.4. Radio-influence voltage was measured at the frequency 1.0 MHz in accordance with circuit diagram in Figure 3 – 3a of NEMA No. 107, Section 3. The test arrangement was set up according to ANSI C29.1, cl. 4.9.1. Radio-influence Voltage (RIV) Test Results Station post insulator b (in Hg) t (°F) VT (kV) 97 88 79 70 61 0 Sample No.1 Sample No.2 Sample No. 3 29.03 59.5 RIV (µV) 6 6 6 6 6 6 29.03 59.7 RIV (µV) 6 6 6 6 6 6 29.03 59.7 RIV (µV) 6 6 6 6 6 6 Rated value: ma. 200 µV at 88 kV/1.0 MHz Measured values of radio-influence voltages on post insulators at test voltage 88kV (1MHz) are less than 200 µV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 288, Catalog No. 288SU0650 passed radio-influence voltage tests according to ANSI C29.9, cl. 7.2.4. 7.2.5 Thermal Shock Test The test was carried out on three post insulator according to ANSI C 29.9, cl 7.2.5. Each tested post insulator was first immersed in a hot water bath 150 °F (66 °C) for 10 minutes. Then it was withdrawn and immersed in a cold water bath 39 °F (4 °C) for 10 minutes. After tenth cycle each post insulator was tested for electrical soundness by low-frequency momentary flashover voltage test. Thermal Shock Test Results Test sample #1 Test sample #2 Test sample #3 10 cycles (150 °F/ 10 min and 39 °F/ 10 min) No failure No failure No failure Low-frequency Momentary Flashover Voltage Test Flashover voltage (kV) Result No failure No failure No failure 410 404 413 Passed Passed Passed No Failure occurred during the thermal shock test according to ANSI C29.9, cl. 7.2.5. All test samples met the requirements. Station post insulator TR 288, Catalog No. 288SU0650 passed thermal shock test according to ANSI C29.9, cl. 7.2.5. Page 3 of 5 GAMMA-CERISOL Catalog 288SU0650 Design Test Certification 7.2.6 Compression Strength Test Temperature 68 -71.6 °F (20-22 °C), Minimum failing load 60,000 lbs. (266.880 kN). Smooth increase in load 450 - 900 lbs. /s. (2 - 4 kN/s), Smooth load up until 67,442.68 lbs. (300 kN), 3 sec hold on this level and unloading, visual inspection. Compression Strength Test Results Sample No. 1 2 3 Load 67,442.68 lbs. (300 kN) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed 7.2.7 Torsional Strength Test Temperature during test + 73.4 °F (+ 23 °C), Minimum failing load (MFL) 40,000 lb.-in. (4.52 kNm), Smooth increase in load 265.52- 442.54 lb.-in./s (0.03 – 0.05 kNm/s), Smooth load up until 44,253.73 lb.-in. (5 kNm), 3 sec hold on this level and unloading, visual inspection. Torsional Strength Test Results Sample No. 1 2 3 Torsional moment 44,253.73 lb.-in. (5 kNm) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed 7.3.4 Cantilever Strength Test Temperature during test + 71.6 °F (+ 22 °C), Minimum failing load (MFL) 1,400 lbs. (6.227 kN), Increase in load 6.74 – 13.49 lbs. /s (0.03 - 0.06 kN/s), smoothly until failure Cantilever Strength Test Results Sample No. Maximum failing load lbs. (kN) Way of failure Result (MFL) 1 2 3 2,592.05 lbs. (11.53kN) 2,189.64 lbs. ( 9.74kN) 2,297.55 lbs. (10.22kN) Failed at bottom part of ceramic core Failed at bottom part of ceramic core Failed at bottom part of ceramic core Passed Passed Passed Average 2,358.25 lbs. (10.49kN) Page 4 of 5 GAMMA-CERISOL Catalog 288SU0650 Design Test Certification 7.3.5 Tensile strength Temperature 68 – 69.8 °F (20-21 °C), Minimum failing load (MFL) 20,000 lbs. (88.96 kN), Increase in load 6.74 – 13.49 lbs./s (0.3 – 0.6 kN/s), smoothly. Smooth load up until 21,356.85.07 lbs. (95 kN), 3 sec hold on this level and unloading, visual inspection. Tensile Strength Test Results Sample No. 1 2 3 Load 21,356.07 lbs. (95 kN) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed Tests performed at EGU HV Laboratory a. s., Test No.10060/B/14, and The Klokner Institute, Report No. 57/14/AL. All test results contained in this document are held on file under drawing number reference H21288EJ. __________________________________ Frank Escobar Chief Engineer, GAMMA Insulators Corporation Page 5 of 5 Design Test Certification Material Tested GAMMA-CERISOL Catalog Number 308HU0900 TEST OBJECT: Station Post Insulator TYPE SPECIFICATION: TR 308 TEST STANDARDS: ANSI C29.9, ANSI C29.1, NEMA No. 107:1993 SCHEDULE OF TESTS Design Tests, Section 7.2 Page Test Section Description of Test Electrical Tests 2 7.2.1 Low-frequency Wet Withstand Voltage 3 7.2.2 & 7.2.3 Critical Impulse Flashover Positive & Impulse Withstand Voltage 5 7.2.4 Radio-influence voltage tests Mechanical Tests 6 7.2.5 Thermal shock test 7 7.2.6 Compression Strength 8 7.2.7 Torsional Strength Quality Conformance Tests, Section 7.3 9 7.3.4 Cantilever Strength 10 7.3.5 Tensile Strength All Electrical tests were performed per the requirements of ANSI test standard C29.9:2012, ANSI C29.1:2012, and NEMA No. 107:1993. All Mechanical tests were performed per the requirements of ANSI test standard C29.9 - 1983 (R1996), and ANSI C29.1 – 1988 (R2002). GAMMA-CERISOL Catalog 308HU0900 Design Test Certification 7.2.1 Low-frequency Wet Withstand Voltage The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.1. The rated wet withstand voltage was applied on each of the tested post insulator for 10 seconds. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Low-frequency Wet Withstand Voltage Test Results b (in Hg) t (°F) r.i. (mm/min) Rw (Ωm) VLW (kV) T (s) result Sample No. 1 28.79 60.6 5.0 200.0 385 10 No flashover occurred Station post insulator Sample No.2 28.79 60.6 5.0 200.0 385 10 No flashover occurred Sample No.3 28.79 60.6 5.0 200.0 385 10 No flashover occurred No flashover occurred during the test at the rated wet withstand voltage 385 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 308, Catalog No. 308HU0900 passed low-frequency wet withstand voltage tests according to ANSI C29.9, cl. 7.2.1. 7.2.2 & 7.2.3 Impulse Withstand Voltage Test and Flashover Voltage The tests were carried out on the three post insulators according to ANSI C29.9, cl. 7.2.2 and 7.2.3. Three consecutive impulses of the rated impulse-withstand value of both polarities were applied on each of tested post insulator. The critical impulse voltages of both polarities were determined by the up and down method with 30 impulses. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Impulse Withstand Voltage and Flashover Voltage Test Results Polarity Test Sample No. VIW (kV) Impulses Flashovers b (in Hg) t (°F) Kh Kd VCRS LI (kV) VCRSA LI (kV) 1 1010 3 0 28.79 61.0 1.064 0.992 1112 + 2 1010 3 0 28.79 61.0 1.064 0.992 1105 1108 3 1010 3 0 28.79 61.0 1.064 0.992 1106 1 1010 3 0 28.79 61.0 1.056 0.992 1277 2 1010 3 0 28.79 61.0 1.056 0.992 1277 1284 3 1010 3 0 28.79 61.0 1.056 0.992 1299 No flashover occurred during the test with three impulses at the rated impulse-withstand voltage 1010 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 308, Catalog No. 308HU0900 passed impulse withstand voltage tests according to ANSI C29.9, cl. 7.2.3. The rated critical-impulse flashover voltage 1010 kV is specified by ANSI C29.9, Table 2. The average values of critical-impulse flashover voltages are higher than 92 percent of the rated critical-impulse flashover voltage, i.e. 929 kV. All test samples met Page 2 of 5 the requirements. Station post insulator TR 308, Catalog No. 308HU0900 passed critical impulse flashover voltage tests according to ANSI C29.9, cl. 7.2.2. GAMMA-CERISOL Catalog 308HU0900 Design Test Certification 7.2.4 Radio-influence Voltage (RIV) Test The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.4. Radio-influence voltage was measured at the frequency 1.0 MHz in accordance with circuit diagram in Figure 3 – 3a of NEMA No. 107, Section 3. The test arrangement was set up according to ANSI C29.1, cl. 4.9.1. Radio-influence Voltage (RIV) Test Results Station post insulator b (in Hg) t (°F) VT (kV) 161 146 131 116 101 86 71 0 Sample No.1 Sample No.2 Sample No. 3 29.00 60.3 RIV (µV) 141 45 10 6 6 6 6 6 29.00 60.3 RIV (µV) 63 32 20 11 7 6 6 6 29.00 60.4 RIV (µV) 100 50 14 9 6 6 6 6 Rated value: ma. 500 µV at 146 kV/1.0 MHz Measured values of radio-influence voltages on post insulators at test voltage 146kV (1MHz) are less than 500 µV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 308, Catalog No. 308HU0900 passed radio-influence voltage tests according to ANSI C29.9, cl. 7.2.4. 7.2.5 Thermal Shock Test The test was carried out on three post insulator according to ANSI C 29.9, cl 7.2.5. Each tested post insulator was first immersed in a hot water bath 150 °F (66 °C) for 10 minutes. Then it was withdrawn and immersed in a cold water bath 39 °F (4 °C) for 10 minutes. After tenth cycle each post insulator was tested for electrical soundness by low-frequency momentary flashover voltage test. Thermal Shock Test Results Test sample #1 Test sample #2 Test sample #3 10 cycles (150 °F/ 10 min, and 39 °F/ 10 min) No failure No failure No failure Low-frequency Momentary Flashover Voltage Test No failure No failure No failure Flashover voltage (kV) 596 585 591 Result Passed Passed Passed No Failure occurred during the thermal shock test according to ANSI C29.9, cl. 7.2.5. All test samples met the requirements. Station post insulator TR 308, Catalog No. 308HU0900 passed thermal shock test according to ANSI C29.9, cl. 7.2.5. Page 3 of 5 GAMMA-CERISOL Catalog 308HU0900 Design Test Certification 7.2.6 Compression Strength Test Temperature 68 -71.6 °F (20-22 °C), Minimum failing load 75,000 lbs. (333.6 kN). Smooth increase in load 450 - 900 lbs. /s. (2 - 4 kN/s), Smooth load up until 89,923 lbs. (400 kN), 3 sec hold on this level and unloading, visual inspection. Compression Strength Test Results Load 89,923 lbs. (400kN) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Sample No. 1 2 3 Result (MFL) Passed Passed Passed 7.2.7 Torsional Strength Test Temperature during test + 73.4 °F (+ 23 °C), Minimum failing load (MFL) 90,000 lb.-in. (10.17 kNm), Smooth increase in load 265.52- 442.54 lb.-in./s (0.03 – 0.05 kNm/s), Smooth load up until 92,932.83 lb.-in. (10.5 kNm), 3 sec hold on this level and unloading, visual inspection. Torsional Strength Test Results Torsional moment 92,932.83 lb.-in. (10.5 kNm) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Sample No. 1 2 3 Result (MFL) Passed Passed Passed 7.3.4 Cantilever Strength Test Temperature during test + 71.6 °F (+ 22 °C), Minimum failing load (MFL) 1,450 lbs. (6.45 kN), Increase in load 6.74 – 13.49 lbs. /s (0.03 - 0.06 kN/s), smoothly until failure Cantilever Strength Test Results Sample No. Maximum failing load, lbs. (kN) Way of failure Result (MFL) 1 1,978.32 (8.8) Failed at bottom part of ceramic core Passed 2 2,176.15 (9.68) Failed at bottom part of ceramic core Passed 3 2,000.80 (8.9) Failed at bottom part of ceramic core Passed Average 2,050.26 (9.12) Page 4 of 5 GAMMA-CERISOL Catalog 308HU0900 Design Test Certification 7.3.5 Tensile strength Temperature 68 – 69.8 °F (20-21 °C), Minimum failing load (MFL) 25,000 lbs. (111.2 kN), Increase in load 6.74 – 13.49 lbs./s (0.3 – 0.6 kN/s), smoothly. Smooth load up until 26,977.07 lbs. (120 kN), 3 sec hold on this level and unloading, visual inspection. Tensile Strength Test Results Sample No. 1 2 3 Load 26,977.07 lbs. (120 kN) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed Tests performed at EGU HV Laboratory a. s., Test No.10060/C/14, and The Klokner Institute, Report No. 56/14/AL. All test results contained in this document are held on file under drawing number reference H21308EJ. __________________________________ Frank Escobar Chief Engineer, GAMMA Insulators Corporation Page 5 of 5 Design Test Certification Material Tested GAMMA-CERISOL Catalog Number 369ET1300 TEST OBJECT: Station Post Insulator TYPE SPECIFICATION: TR 369 TEST STANDARDS: ANSI C29.9, ANSI C29.1, NEMA No. 107:1993 SCHEDULE OF TESTS Design Tests, Section 7.2 Page Test Section Description of Test Electrical Tests 2 7.2.1 Low-frequency Wet Withstand Voltage 3 7.2.2 & 7.2.3 Critical Impulse Flashover Positive & Impulse Withstand Voltage 5 7.2.4 Radio-influence voltage tests Mechanical Tests 6 7.2.5 Thermal shock test 7 7.2.6 Compression Strength 8 7.2.7 Torsional Strength Quality Conformance Tests, Section 7.3 9 7.3.4 Cantilever Strength 10 7.3.5 Tensile Strength All Electrical tests were performed per the requirements of ANSI test standard C29.9:2012, ANSI C29.1:2012, and NEMA No. 107:1993. All Mechanical tests were performed per the requirements of ANSI test standard C29.9 - 1983 (R1996), and ANSI C29.1 – 1988 (R2002). Page 1 of 5 GAMMA-CERISOL Catalog 369ET1300 Design Test Certification 7.2.1 Low-frequency Wet Withstand Voltage The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.1. The rated wet withstand voltage was applied on each of the tested post insulator for 10 seconds. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Low-frequency Wet Withstand Voltage Test Results Station post insulator Sample No. 1 Sample No.2 28.82 28.82 59.4 59.4 4.9 4.9 200.0 200.0 525 525 10 10 No flashover occurred No flashover occurred b (in Hg) t (°F) r.i. (mm/min) Rw (Ωm) VLW (kV) T (s) result Sample No.3 28.82 59.4 4.9 200.0 525 10 No flashover occurred No flashover occurred during the test at the rated wet withstand voltage 525 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 369, Catalog No. 369ET1300 passed low-frequency wet withstand voltage tests according to ANSI C29.9, cl. 7.2.1. 7.2.2 & 7.2.3 Impulse Withstand Voltage Test and Flashover Voltage The tests were carried out on the three post insulators according to ANSI C29.9, cl. 7.2.2 and 7.2.3. Three consecutive impulses of the rated impulse-withstand value of both polarities were applied on each of tested post insulator. The critical impulse voltages of both polarities were determined by the up and down method with 30 impulses. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Impulse Withstand Voltage and Flashover Voltage Test Results Polarity + - Test sample no. 1 2 3 1 2 3 VIW (kV) Impulses Flashovers b (in Hg) t (°F) Kh Kd VCRS LI (kV) VCRSA LI (kV) 1410 3 0 28.82 60.6 1.073 0.994 1470 1410 3 0 28.88 60.4 1.066 0.996 1438 1451 1410 3 0 28.82 60.6 1.073 0.994 1446 1410 3 0 28.82 60.6 1.064 0.994 1650 1410 3 0 28.88 60.4 1.058 0.996 1645 1645 1410 3 0 28.82 60.6 1.064 0.994 1639 No flashover occurred during the test with three impulses at the rated impulse-withstand voltage 1410 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 369, Catalog No. 369ET1300 passed impulse withstand voltage tests according to ANSI C29.9, cl. 7.2.3. The rated critical-impulse flashover voltage 1410 kV is specified by ANSI C29.9, Table 2. The average values of critical-impulse flashover voltages are higher than 92 percent of the rated critical-impulse flashover voltage, i.e. 1297 kV. All test samples met Page 2 of 5 the requirements. Station post insulator TR 369, Catalog No. 369ET1300 passed critical impulse flashover voltage tests according to ANSI C29.9, cl. 7.2.2. GAMMA-CERISOL Catalog 369ET1300 Design Test Certification 7.2.4 Radio-influence Voltage (RIV) Test The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.4. Radio-influence voltage was measured at the frequency 1.0 MHz in accordance with circuit diagram in Figure 3 – 3a of NEMA No. 107, Section 3. The test arrangement was set up according to ANSI C29.1, cl. 4.9.1. Radio-influence Voltage (RIV) Test Results Station post insulator b (in Hg) t (°F) VT (kV) 242 220 198 176 154 132 110 88 66 0 Sample No.1 Sample No.2 Sample No. 3 29.03 59.7 RIV (µV) 631 355 251 158 126 100 79 5 5 5 29.03 59.7 RIV (µV) 794 501 316 224 126 100 7 5 5 5 29.03 59.9 RIV (µV) 631 447 282 224 126 100 9 5 5 5 Rated value: ma. 1000 µV at 220 kV/1.0 MHz Measured values of radio-influence voltages on post insulators at test voltage 220kV (1MHz) are less than 1000 µV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 369, catalog No. 369ET1300 passed radioinfluence voltage tests according to ANSI C29.9, cl. 7.2.4. 7.2.5 Thermal Shock Test The test was carried out on three post insulator according to ANSI C 29.9, cl 7.2.5. Each tested post insulator was first immersed in a hot water bath 150 °F (66 °C) for 10 minutes. Then it was withdrawn and immersed in a cold water bath 39 °F (4 °C) for 10 minutes. After tenth cycle each post insulator was tested for electrical soundness by low-frequency momentary flashover voltage test. Thermal Shock Test Results Test sample #1 Test sample #2 Test sample #3 10 cycles (150 °F/ 10 min and 39 °F/ 10 min) No failure No failure No failure Low-frequency Momentary Flashover Voltage Test No failure No failure No failure Flashover voltage (kV) 764 752 760 Result Passed Passed Passed No Failure occurred during the thermal shock test according to ANSI C29.9, cl. 7.2.5. All test samples met the requirements. Station post insulator TR 369, Catalog No. 369ET1300 passed thermal shock test according to ANSI C29.9, cl. 7.2.5. Page 3 of 5 GAMMA-CERISOL Catalog 369ET1300 Design Test Certification 7.2.6 Compression Strength Test Temperature 68 -71.6 °F (20-22 °C), Minimum failing load 60,000 lbs. (266.880 kN). Smooth increase in load 450 - 900 lbs. /s. (2 - 4 kN/s), Smooth load up until 89,923 lbs. (400 kN), 3 sec hold on this level and unloading, visual inspection. Compression Strength Test Results Load 89,923 lbs. Load (400 kN) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Sample No. 1 2 3 Result (MFL) Passed Passed Passed 7.2.7 Torsional Strength Test Temperature during test + 73.4 °F (+ 23 °C), Minimum failing load (MFL) 40,000 lb.-in. (4.52 kNm), Smooth increase in load 265.52- 442.54 lb.-in./s (0.03 – 0.05 kNm/s), Smooth load up until 44,253.73 lb.-in. (5 kNm), 3 sec hold on this level and unloading, visual inspection. Torsional Strength Test Results Sample No. 1 2 3 Torsional moment 44,248 lb.-in. (5 kNm) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed 7.3.4 Cantilever Strength Test Temperature during test + 71.6 °F (+ 22 °C), Minimum failing load (MFL) 2,050 lbs. (9.118 kN), Increase in load 9.0 – 15.74 lbs. /s (0.04 - 0.07 kN/s), smoothly until failure Cantilever Strength Test Results Sample No. Maximum failing load lbs. (kN) Way of failure Result (MFL) 1 3,331.67 (14.82) Failed at bottom part of ceramic core Passed 2 3,167.56 (14.09) Failed at bottom part of ceramic core Passed 3 2,542.59 (11.31) Failed at bottom part of ceramic core Passed Average 3,012.44 (13.4) Page 4 of 5 GAMMA-CERISOL Catalog 369ET1300 Design Test Certification 7.3.5 Tensile strength Temperature 68 – 69.8 °F (20-21 °C), Minimum failing load (MFL) 20,000 lbs. (88.960 kN), Increase in load 6.74 – 13.49 lbs./s (0.3 – 0.6 kN/s), smoothly. Smooth load up until 26,977.07 lbs. (120 kN), 3 sec hold on this level and unloading, visual inspection. Tensile Strength Test Results Sample No. 1 2 3 Load 26,977.07 lbs. (120 kN Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed Tests performed at EGU HV Laboratory a. s., Test No.10060/D/14, and The Klokner Institute, Report No. 55/14/AL. All test results contained in this document are held on file under drawing number reference H21369EJ. __________________________________ Frank Escobar Chief Engineer, GAMMA Insulators Corporation Page 5 of 5 Design Test Certification Material Tested GAMMA-CERISOL Catalog Number 391ST1800 TEST OBJECT: Station Post Insulator TYPE SPECIFICATION: TR 391 TEST STANDARDS: ANSI C29.9, ANSI C29.1, NEMA No. 107:1993 SCHEDULE OF TESTS Design Tests, Section 7.2 Page Test Section Description of Test Electrical Tests 2 7.2.1 Low-frequency Wet Withstand Voltage 3 7.2.2 & 7.2.3 Critical Impulse Flashover Positive & Impulse Withstand Voltage 5 7.2.4 Radio-influence voltage tests Mechanical Tests 6 7.2.5 Thermal shock test 7 7.2.6 Compression Strength 8 7.2.7 Torsional Strength Quality Conformance Tests, Section 7.3 9 7.3.4 Cantilever Strength 10 7.3.5 Tensile Strength All Electrical tests were performed per the requirements of ANSI test standard C29.9:2012, ANSI C29.1:2012, and NEMA No. 107:1993. All Mechanical tests were performed per the requirements of ANSI test standard C29.9 - 1983 (R1996), and ANSI C29.1 – 1988 (R2002). Page 1 of 5 GAMMA-CERISOL Catalog 391ST1800 Design Test Certification 7.2.1 Low-frequency Wet Withstand Voltage The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.1. The rated wet withstand voltage was applied on each of the tested post insulator for 10 seconds. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Low-frequency Wet Withstand Voltage Test Results Station post insulator Sample No. 1 Sample No.2 Sample No.3 b (in Hg) 29.4 29.4 29.4 t (°F) 59.2 59.2 59.2 r.i. (mm/min) 5.0 5.0 5.0 Rw (Ωm) 200.0 200.0 200.0 VLW (kV) 710 710 710 T (s) 10 10 10 result No flashover occurred No flashover occurred No flashover occurred No flashover occurred during the test at the rated wet withstand voltage 230 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 391, Catalog No. 391ST1800 passed low-frequency wet withstand voltage tests according to ANSI C29.9, cl. 7.2.1. 7.2.2 & 7.2.3 Impulse Withstand Voltage Test and Flashover Voltage The tests were carried out on the three post insulators according to ANSI C29.9, cl. 7.2.2 and 7.2.3. Three consecutive impulses of the rated impulse-withstand value of both polarities were applied on each of tested post insulator. The critical impulse voltages of both polarities were determined by the up and down method with 30 impulses. The test arrangement was set up according to ANSI C29.1, cl. 3.3 Impulse Withstand Voltage and Flashover Voltage Test Results Polarity Test Sample No. VIW (kV) Impulses Flashovers b (in Hg) t (°F) Kh Kd VCRS LI (kV) VCRSA LI (kV) 1 1800 3 0 29.0 60.1 1.001 1.073 2143 + 2 1800 3 0 29.0 60.1 1.001 1.073 2139 2131 3 1800 3 0 29.0 60.1 1.001 1.073 2110 1 1800 3 0 29.0 60.1 1.001 1.064 2316 2 1800 3 0 29.0 60.1 1.001 1.064 2292 2303 3 1800 3 0 29.0 60.1 1.001 1.064 2302 No flashover occurred during the test with three impulses at the rated impulse-withstand voltage 1800 kV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 391, Catalog No. 391ST1800 passed impulse withstand voltage tests according to ANSI C29.9, cl. 7.2.3. The rated critical-impulse flashover voltage 2000 kV is specified by ANSI C29.9, Table 2. The average values of critical-impulse flashover voltages are higher than 92 percent of the rated critical-impulse flashover voltage, i.e. 1840 kV. All test samples met the requirements. Station post insulator TR 391, Catalog No. 391ST1800 passed critical-impulse flashover voltage tests according to ANSI C29.9, cl. 7.2.2. Page 2 of 5 GAMMA-CERISOL Catalog 391ST1800 Design Test Certification 7.2.4 Radio-influence Voltage (RIV) Test The tests were carried out on three post insulators according to ANSI C29.9, cl. 7.2.4. Radio-influence voltage was measured at the frequency 1.0 MHz in accordance with circuit diagram in Figure 3 – 3a of NEMA No. 107, Section 3. The test arrangement was set up according to ANSI C29.1, cl. 4.9.1. Radio-influence Voltage (RIV) Test Results Station post insulator b (in Hg) t (°F) VT (kV) 350 318 286 254 222 190 158 126 0 Sample No.1 Sample No.2 Sample No. 3 29.03 60.1 RIV (µV) 562 100 56 32 20 5 5 5 5 29.03 60.1 RIV (µV) 562 112 63 28 20 5 5 5 5 29.03 60.1 RIV (µV) 794 89 56 35 18 5 5 5 5 Rated value: ma. 2000 µV at 318 kV/1.0 MHz Measured values of radio-influence voltages on post insulators at test voltage 318kV (1MHz) are less than 2000 µV specified by ANSI C29.9, Table 2. All test samples met the requirements. Station post insulator TR 391, Catalog No. 391ST1800 passed radio-influence voltage tests according to ANSI C29.9, cl. 7.2.4. 7.2.5 Thermal Shock Test The test was carried out on three post insulator according to ANSI C 29.9, cl 7.2.5. Each tested post insulator was first immersed in a hot water bath 150 °F (66 °C) for 10 minutes. Then it was withdrawn and immersed in a cold water bath 39 °F (4 °C) for 10 minutes. After tenth cycle each post insulator was tested for electrical soundness by low-frequency momentary flashover voltage test. Thermal Shock Test Results Test sample #1 Test sample #2 Test sample #3 10 cycles (150 °F/ 10 min and 39 F/ 10 min) No failure No failure No failure Low-frequency Momentary Flashover Voltage Test No failure No failure No failure Flashover voltage (kV) Result 937 945 929 Passed Passed Passed No Failure occurred during the thermal shock test according to ANSI C29.9, cl. 7.2.5. All test samples met the requirements. Station post insulator TR 391, Catalog No. 391ST1800 passed thermal shock test according to ANSI C29.9, cl. 7.2.5. Page 3 of 5 GAMMA-CERISOL Catalog 391ST1800 Design Test Certification 7.2.6 Compression Strength Test Temperature 68 -71.6 °F (20-22 °C), Minimum failing load 60,000 lbs. (266.880 kN). Smooth increase in load 450 - 900 lbs. /s. (2 - 4 kN/s), Smooth load up until 89,923 lbs. (400 kN), 3 sec hold on this level and unloading, visual inspection. Compression Strength Test Results Load 89,923 (400 kN), Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Sample No. 1 2 3 Result (MFL) Passed Passed Passed 7.2.7 Torsional Strength Test Temperature during test + 73.4 °F (+ 23 °C), Minimum failing load (MFL) 40,000 lb.-in. (4.52 kNm), Smooth increase in load 265.52- 442.54 lb.-in./s (0.03 – 0.05 kNm/s), Smooth load up until 44,253.72 lb.-in. (5 kNm), 3 sec hold on this level and unloading, visual inspection. Torsional Strength Test Results Sample No. 1 2 3 Torsional moment 44,253.72 lb.-in (5 kNm) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed 7.3.4 Cantilever Strength Test Temperature during test + 71.6 °F (+ 22 °C), Minimum failing load (MFL) 1,400 lbs. (6.227 kN), Increase in load 6.74 – 13.49 lbs. /s (0.03 - 0.06 kN/s), smoothly until failure Cantilever Strength Test Results Sample No. Maximum failing load [kN] Way of failure Result (MFL) 1 2 3 9.26 7.04 7.84 Failed at bottom part of ceramic core Failed at bottom part of ceramic core Failed at bottom part of ceramic core Passed Passed Passed Average 8.05 Page 4 of 5 GAMMA-CERISOL Catalog 391ST1800 Design Test Certification 7.3.5 Tensile strength Temperature 68 – 69.8 °F (20-21 °C), Minimum failing load (MFL) 20,000 lbs. (88.960 kN), Increase in load 6.74 – 13.49 lbs./s (0.3 – 0.6 kN/s), smoothly. Smooth load up until 26,977.07 lbs. (120 kN), 3 sec hold on this level and unloading, visual inspection. Tensile Strength Test Results Sample No. 1 2 3 Load 26,977.07 lbs. (120 kN) Applied for 3 sec Insulator did not fail Insulator did not fail Insulator did not fail Result (MFL) Passed Passed Passed Tests performed at EGU HV Laboratory a. s., Test No.10060/E/14, and The Klokner Institute, Report No. 54/14/AL. All test results contained in this document are held on file under drawing number reference H21391EJ. __________________________________ Frank Escobar Chief Engineer, GAMMA Insulators Corporation Page 5 of 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2015:07:13 07:32:52Z Creator : AutoCAD LT 2015 - English 2015 (20.0s (LMS Tech)) Modify Date : 2015:10:15 09:16:28-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : AutoCAD LT 2015 - English 2015 (20.0s (LMS Tech)) Metadata Date : 2015:10:15 09:16:28-05:00 Producer : pdfplot12.hdi 12.0.51.0 Format : application/pdf Title : Model Document ID : uuid:684b5be7-9502-4d51-92de-552e77cd6789 Instance ID : uuid:ca72ad67-806f-452a-8906-7b3fb9d26fcc Page Layout : SinglePage Page Mode : UseOC Page Count : 77EXIF Metadata provided by EXIF.tools