Dlt Trf Psg
2018-08-28
: Pdf Dlt Trf Psg dlt_trf_psg psg products dual-lite
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
TRF Three-Phase Systems - 10KVA to 125KVA FEATURES AC output provides full lumen output for emergency lighting loads in commercial or industrial applications Compatible with any lighting load including incandescent, HID, fluorescent and LED lamps Painted steel enclosure and double conversion online operation Maintenance-free batteries with fully automatic solid state charger Form C contact closure points standard on all models 24 hour recharge time Temperature range: 20°C to 30°C (68°F to 86°F) OSHPD seismic qualification on 65 - 125KVA sizes UL 924 Listed • I N V E RT E R S • • • • • • • • ORDERING INFORMATION TRF MODEL INPUT VOLTAGE 208¹ 208VAC 480 480VAC INPUT CONDUCTOR 3 3 Wire 42 4 Wire 10 15 20 30 40 50 60 65 80 100 125 CAPACITY 10KVA/9KW 15KVA/13KW 20KVA/18KW 30KVA/27KW 40KVA/36KW 50KVA/45KW 60KVA/54KW 65KVA/58KW 80KVA/72KW 100KVA/90KW 125KVA/112KW OUTPUT VOLTAGE 208 208VAC 4803 480VAC A B C D E OPTIONS6,7 SNMP/Web Card SNMP/Web Card & Env. Sensor Top Entry Cabinet SNMP Card & Top Entry Cabinet SNMP Card, Env. Sensor & Top Entry Cabinet FACTORY START-UPS (REQUIRED)4 FST-1 Factory Start-Up 10 - 30kVA FST-2 Factory Start-Up 40 - 80kVA FST-3 Factory Start-Up > 80kVA TRF-RSP-1 TRF-RSP-2 TRF-SFK-1 TRF-SFK-2 ACCESSORIES Remote Status Panel 10-60kVA Remote Status Panel 65-125kVA Seismic Mounting 10-40kVA Seismic Mounting 50-60kVA 1 Only available with 208VAC output voltage. Only available with 480VAC output voltage (all capacities), and with 208 VAC input voltage on 10KVA through 65KVA capacities Only available with 480VAC input voltage. 4 Start-up must be performed by an Authorized Service Center within 6 months of shipment to maintain battery warranty. 5 Batteries must be connected to an energized charging circuit within 90 days from date of shipment or warranty is void. 6 Alternate run times and 50Hz models available on request; consult factory. 7 SNMP/web card: Internal SNMP Card allows inverter management acrosss a LAN using any of the main network communication protocols. - TCP/IP, HTTP and network interface (SNMP). SNMP/Web Card & Env. Sensor: SNMP card with an environmental sensor module that senses temperature, humidity and smoke and displays it via SNMP. Top Entry Cabinet: Provides additional compartments to allow for top conduit entry. 2 3 Cabinet Configurations Cabinet Configurations Cabinet Cabinet Configuration Configurati CABINET CONFIGURATIONS ELECTRONICS • Uninterruptible "no break" transfer • Microprocessor controlled pulse width modulation (PWM) using IGBT technology • Transient surge, LVD, short-circuit, current limiting, overload and brown-out protection • Self-test diagnostic circuitry • True sine wave output; optional runtime available • Digital controls with graphic user interface with LED and audible Configuration A indicators Configuration B alarm systemConfiguration C Configuration D • Load power factor range of 0.9 leading to 0.5 lagging without derating (may not exceed KVA rating) rations Configuration A Configuration B • Internal power factor of 0.90 to yield KW rating Configuration I Configuration G Configuration Configuration E E Configuration E Configuration C Configuration Configuration B Configuration Configuration A AA Configuration Configuration B B Configuration Configuration F F Configuration H Configuration G Configuration G Configuration J Configuration I Configuration I Configuration H Configuration Configuration G G Configuration Configuration H H Configuration Configuration J J Configuration I Configurati Config Configuration L Configuration K Configuration J Configuration E Configuration DD Configuration Configuration D Configuration H Configuration K Configuration J Configuration F Configuration D Configuration CC Configuration Configuration C Configuration L Configuration K Configuration Configuration K K Configuration L TRF Three Phase Central Lighting Inverters – 10KVA to 125KVA SPECIFICATIONS UPS Rating AC Voltage AC Current Battery Recommended OCPD Mechanical Data Input (VAC) Output (VAC) Bypass (VAC) Input Nom (A) Input Max (A) Output Nom (A) Nom. (VDC) Discharge (A) Input Output DC No. of Cab. Cab. Config. Width (in) Depth (in) Height (in) Weight (lbs) Heat Dis. (BTU/hr) 10/9 10/9 10/9 10/9 10/9 208V 208Y/120V 480V 480V 480Y/277V 208Y/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 27.8 27.1 12.1 12.2 12.1 33.4 32.6 14.5 14.7 14.5 27.8 27.8 27.8 12.0 12.0 432 432 432 432 432 26.5 26.5 26.5 26.9 26.9 45 40 20 20 20 35 35 35 15 15 35 35 35 35 35 2 2 2 2 2 A A A A A 49.2 49.2 49.2 49.2 49.2 35.6 35.6 35.6 35.6 35.6 72.4 72.4 72.4 72.4 72.4 2,351 2,171 2,381 2,481 2,371 3200 2400 3200 3700 3400 15/13 15/13 15/13 15/13 15/13 208V 208Y/120V 480V 480V 480Y/277V 208Y/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 41.7 40.7 18.1 18.4 18.2 50.1 48.8 21.7 22.0 21.8 41.6 41.6 41.6 18.0 18.0 432 432 432 432 432 39.8 39.8 39.8 40.4 40.4 70 60 30 30 30 60 60 60 25 25 50 50 50 60 60 2 2 2 2 2 B B B B B 59.1 59.1 59.1 59.1 59.1 34.5 34.5 34.5 34.5 34.5 78.7 78.7 78.7 78.7 78.7 3,439 3,189 3,439 3,639 3,589 4800 3500 4800 5600 5000 20/18 20/18 20/18 20/18 20/18 208V 208Y/120V 480V 480V 480Y/277V 208/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 55.7 54.3 24.1 24.5 24.2 66.8 65.1 28.9 29.4 29.1 55.5 55.5 55.5 24.1 24.1 432 432 432 432 432 53.1 53.1 53.1 53.9 53.9 90 80 35 40 40 70 70 70 30 30 70 70 70 70 70 2 2 2 2 2 C C C C C 63.1 63.1 63.1 63.1 63.1 34.5 34.5 34.5 34.5 34.5 78.7 78.7 78.7 78.7 78.7 4319 4,089 4,389 4,619 4,549 6400 4700 6400 7400 6700 30/27 30/27 30/27 30/27 30/27 208V 208Y/120V 480V 480V 480Y/277V 208Y/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 83.5 81.4 36.2 36.7 36.4 100.2 97.7 43.4 44.1 43.6 83.3 83.3 83.3 36.1 36.1 432 432 432 432 432 79.6 79.6 79.6 80.8 80.8 125 125 60 60 60 110 110 110 50 50 100 100 100 110 110 3 3 3 3 3 D D D D D 99.1 99.1 99.1 99.1 99.1 34.5 34.5 34.5 34.5 34.5 78.7 78.7 78.7 78.7 78.7 6,509 6,079 6,509 6,774 6,609 9500 7000 9500 11100 10000 40/36 40/36 40/36 40/36 40/36 208V 208Y/120V 480V 480V 480Y/277V 208Y/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 111.3 108.5 48.2 49.0 48.5 133.6 130.2 57.9 58.8 58.2 111.0 111.0 111.0 48.1 48.1 432 432 432 432 432 106.2 106.2 106.2 107.8 107.8 175 175 70 80 80 150 150 150 70 70 150 150 150 150 150 3 3 3 3 3 E E E E E 103.1 103.1 103.1 103.1 103.1 34.5 34.5 34.5 34.5 34.5 78.7 78.7 78.7 78.7 78.7 7,953 7,519 7,969 8,239 8,059 12700 9300 12700 14700 13300 50/45 50/45 50/45 50/45 50/45 208V 208Y/120V 480V 480V 480Y/277V 208Y/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 147.1 143.4 63.7 65.4 65.4 176.5 172.0 76.5 78.4 78.4 138.8 138.8 138.8 60.1 60.1 432 432 432 432 432 132.7 132.7 132.7 136.1 136.1 225 225 100 100 100 175 175 175 80 80 175 175 175 175 175 3 3 3 3 3 F F F F F 106.4 106.4 106.4 106.4 106.4 34.3 34.3 34.3 34.3 34.3 78.7 78.7 78.7 78.7 78.7 9,621 9,041 9,451 9,861 9,861 25500 21000 25500 30100 30100 60/54 60/54 60/54 60/54 60/54 208V 208Y/120V 480V 480V 480Y/277V 208Y/120V 208Y/120V 208Y/120V 480Y/277V 480Y/277V 208V 208/120V 480V 480V 480/277V 170.6 166.4 73.9 75.1 74.3 204.8 199.7 88.7 90.1 89.2 166.5 166.5 166.5 72.2 72.2 432 432 432 432 432 159.3 159.3 159.3 161.7 161.7 250 250 110 110 110 225 225 225 100 100 200 200 200 225 225 3 3 3 3 3 F F F F F 106.4 106.4 106.4 106.4 106.4 34.3 34.3 34.3 34.3 34.3 78.7 78.7 78.7 78.7 78.7 9,599 9,041 9,601 10,167 10,173 23500 18300 23500 26600 24500 65/58 65/58 65/58 65/58 208V 480V 480V 480Y/277V 208Y/120V 480/277V 208Y/120V 480Y/277V 208V 480V 480V 480/277V 180.5 78.2 78.2 78.2 209.0 89.0 89.0 89.0 180.4 78.2 180.4 78.2 480 480 480 480 159.5 159.5 159.5 159.5 300 125 125 125 225 125 225 100 160 160 160 160 4 4 4 3 J J J G 137 137 137 103.6 33.5 33.5 33.5 33.5 78.7 78.7 78.7 78.7 12,539 11,909 11,909 10,439 15683 15833 15683 15033 80/72 80/72 80/72 80/72 208V 480V 480V 480Y/277V 208Y/120V 480/277V 208Y/120V 480Y/277V 208V 480V 480V 480/277V 222.2 96.3 96.3 96.3 256.0 109.0 109.0 109.0 222.1 96.2 222.1 96.2 480 480 480 480 196.4 196.4 196.4 196.4 350 150 150 150 300 150 300 125 200 200 200 200 5 5 5 4 K K K H 173 173 173 139.6 33.5 33.5 33.5 33.5 78.7 78.7 78.7 78.7 17,009 16,379 16,739 14,909 19300 19300 19300 18500 100/90 100/90 100/90 100/90 208V 480V 480V 480Y/277V 208Y/120V 480/277V 208Y/120V 480Y/277V 208V 480V 480V 480/277V 277.6 120.3 120.3 120.3 317.0 136.0 136.0 136.0 277.6 120.3 277.6 120.3 480 480 480 480 235.8 235.8 235.8 235.8 400 175 175 175 350 175 350 150 250 250 250 250 5 5 5 4 K K K H 173 173 173 139.6 33.5 33.5 33.5 33.5 78.7 78.7 78.7 78.7 17,119 16,489 16,489 15,019 24120 24120 24120 23120 125/112 125/112 125/112 125/112 208V 480V 480V 480Y/277V 208Y/120V 480/277V 208Y/120V 480Y/277V 208V 480V 480V 480/277V 347.1 150.4 150.4 150.4 360.0 160.0 160.0 160.0 347.0 150.4 347.0 150.4 480 480 480 480 294.8 294.8 294.8 294.8 450 200 200 200 450 200 450 200 300 300 300 300 6 6 6 5 L L L I 209 209 209 175.6 33.5 33.5 33.5 33.5 78.7 78.7 78.7 78.7 21,722 21,092 21,092 19,622 30150 30150 30150 28900 NOTES FOR SITE PLANNING DATA: 1. Input and bypass cables must be run in separate conduit from output cables. 2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per NEC 310-15(B)(4) References are per NEC 2008. 3. Wiring requirements: AC Input: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground AC Output: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground 4. All wiring is to be in accordance with national and local electrical codes. 5. Minimum cabinet access clearance: 3 ft. (0.9m) front, ; 18” (457mm) overhead for up to 65kVA systems and 24” (610mm) overhead for >65kVA systems; 8” (203mm) rear for up to 65kVA systems and 24”(610mm) rear for >65kVA systems. 6. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size then replace. 7. Control wiring and power wiring must be run in separate conduit. 8. Dimensions are system dimensions including UPS, battery cabinets and transformer cabinets (if any).; Transformer cabinets are front access 9. Weights are system weights including UPS, battery cabinets and transformer cabinets (if any).; Transformer cabinets are front access. 10. Heat dissipation includes UPS , battery and transformer cabinet. 11. Recommended AC input external overcurrent protection is based on 80% rated devices and maximum input current limit settings. ADDITIONAL NOTES: • If site configuration includes a back-up emergency generator, it is recommended that the engine generator set be properly sized and equipped for a UPS application. Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS compatible regulator (generator voltage regulation). Consult generator manufacturer for required generator options and sizing. I N V E RT E R S kVA/kW
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47 Instance ID : uuid:42a5b87d-fed4-c441-8cb3-d47fbea66105 Original Document ID : adobe:docid:indd:a5474d74-47f3-11de-a5ae-b70cb1765cd9 Document ID : xmp.id:e458ef5e-e611-4eac-aefc-fa2e55aad84a Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:6d75a830-30b2-42b7-b54b-1ce7dde97dbc Derived From Document ID : xmp.did:f39c9896-f718-479f-bbb3-8df7fa34ebd0 Derived From Original Document ID: adobe:docid:indd:a5474d74-47f3-11de-a5ae-b70cb1765cd9 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.1 (Macintosh) History Changed : / History When : 2018:08:10 13:20:44-04:00 Create Date : 2018:08:10 13:20:44-04:00 Modify Date : 2018:08:10 13:21:08-04:00 Metadata Date : 2018:08:10 13:21:08-04:00 Creator Tool : Adobe InDesign CC 13.1 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 13.1 (Macintosh)EXIF Metadata provided by EXIF.tools