Three-Phase Systems - 10KVA to 125KVA
FEATURES

AC output provides full lumen output for emergency lighting loads in commercial or
industrial applications
Compatible with any lighting load including incandescent, HID, fluorescent
and LED lamps
Painted steel enclosure and double conversion online operation
Maintenance-free batteries with fully automatic solid state charger
Form C contact closure points standard on all models
24 hour recharge time
Temperature range: 20°C to 30°C (68°F to 86°F)
OSHPD seismic qualification on 65 - 125KVA sizes
UL 924 Listed

•

I N V E RT E R S

•
•
•
•
•
•
•
•

ORDERING INFORMATION

TRF
MODEL

INPUT
VOLTAGE
208¹ 208VAC
480 480VAC

INPUT
CONDUCTOR
3 3 Wire
42 4 Wire

10
15
20
30
40
50
60
65
80
100
125

CAPACITY
10KVA/9KW
15KVA/13KW
20KVA/18KW
30KVA/27KW
40KVA/36KW
50KVA/45KW
60KVA/54KW
65KVA/58KW
80KVA/72KW
100KVA/90KW
125KVA/112KW

OUTPUT
VOLTAGE
208 208VAC
4803 480VAC

A
B
C
D
E

OPTIONS6,7
SNMP/Web Card
SNMP/Web Card & Env. Sensor
Top Entry Cabinet
SNMP Card & Top Entry Cabinet
SNMP Card, Env. Sensor &
Top Entry Cabinet

FACTORY START-UPS (REQUIRED)4
FST-1 Factory Start-Up 10 - 30kVA
FST-2 Factory Start-Up 40 - 80kVA
FST-3 Factory Start-Up > 80kVA
TRF-RSP-1
TRF-RSP-2
TRF-SFK-1
TRF-SFK-2

ACCESSORIES
Remote Status Panel 10-60kVA
Remote Status Panel 65-125kVA
Seismic Mounting 10-40kVA
Seismic Mounting 50-60kVA

1

Only available with 208VAC output voltage.
Only available with 480VAC output voltage (all capacities), and with 208 VAC input voltage on 10KVA through 65KVA capacities
Only available with 480VAC input voltage.
4
Start-up must be performed by an Authorized Service Center within 6 months of shipment to maintain battery warranty.
5
Batteries must be connected to an energized charging circuit within 90 days from date of shipment or warranty is void.
6
Alternate run times and 50Hz models available on request; consult factory.
7
SNMP/web card: Internal SNMP Card allows inverter management acrosss a LAN using any of the main network communication protocols. - TCP/IP, HTTP and network interface (SNMP).
SNMP/Web Card & Env. Sensor: SNMP card with an environmental sensor module that senses temperature, humidity and smoke and displays it via SNMP.
Top Entry Cabinet: Provides additional compartments to allow for top conduit entry.
2
3

Cabinet Configurations
Cabinet Configurations
Cabinet
Cabinet
Configuration
Configurati

CABINET CONFIGURATIONS

ELECTRONICS
• Uninterruptible "no break" transfer
• Microprocessor controlled pulse width modulation (PWM) using IGBT technology
• Transient surge, LVD, short-circuit, current limiting, overload and brown-out protection
• Self-test diagnostic circuitry
• True sine wave output; optional runtime available
• Digital controls with graphic user interface
with LED
and audible
Configuration
A indicators
Configuration
B alarm systemConfiguration C

Configuration D

• Load power factor range of 0.9 leading to 0.5 lagging without derating (may not exceed KVA rating)
rations
Configuration A
Configuration B
• Internal power factor of 0.90 to yield KW rating

Configuration I

Configuration G

Configuration
Configuration
E E

Configuration E

Configuration C
Configuration
Configuration
B
Configuration
Configuration
A
AA
Configuration
Configuration
B
B

Configuration
Configuration F F

Configuration H

Configuration G

Configuration G

Configuration J

Configuration I

Configuration I

Configuration H
Configuration
Configuration
G
G

Configuration
Configuration
H
H

Configuration
Configuration
J
J

Configuration I

Configurati
Config

Configuration L

Configuration K
Configuration J

Configuration E
Configuration
DD
Configuration
Configuration
D

Configuration H

Configuration K

Configuration J

Configuration F

Configuration D
Configuration
CC
Configuration
Configuration
C

Configuration L
Configuration K

Configuration
Configuration
K
K

Configuration L

TRF

Three Phase Central Lighting Inverters – 10KVA to 125KVA
SPECIFICATIONS
UPS
Rating

AC Voltage

AC Current

Battery

Recommended OCPD

Mechanical Data

Input
(VAC)

Output
(VAC)

Bypass
(VAC)

Input
Nom
(A)

Input
Max
(A)

Output
Nom
(A)

Nom.
(VDC)

Discharge
(A)

Input

Output

DC

No. of
Cab.

Cab.
Config.

Width
(in)

Depth
(in)

Height
(in)

Weight
(lbs)

Heat Dis.
(BTU/hr)

10/9
10/9
10/9
10/9
10/9

208V
208Y/120V
480V
480V
480Y/277V

208Y/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

27.8
27.1
12.1
12.2
12.1

33.4
32.6
14.5
14.7
14.5

27.8
27.8
27.8
12.0
12.0

432
432
432
432
432

26.5
26.5
26.5
26.9
26.9

45
40
20
20
20

35
35
35
15
15

35
35
35
35
35

2
2
2
2
2

A
A
A
A
A

49.2
49.2
49.2
49.2
49.2

35.6
35.6
35.6
35.6
35.6

72.4
72.4
72.4
72.4
72.4

2,351
2,171
2,381
2,481
2,371

3200
2400
3200
3700
3400

15/13
15/13
15/13
15/13
15/13

208V
208Y/120V
480V
480V
480Y/277V

208Y/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

41.7
40.7
18.1
18.4
18.2

50.1
48.8
21.7
22.0
21.8

41.6
41.6
41.6
18.0
18.0

432
432
432
432
432

39.8
39.8
39.8
40.4
40.4

70
60
30
30
30

60
60
60
25
25

50
50
50
60
60

2
2
2
2
2

B
B
B
B
B

59.1
59.1
59.1
59.1
59.1

34.5
34.5
34.5
34.5
34.5

78.7
78.7
78.7
78.7
78.7

3,439
3,189
3,439
3,639
3,589

4800
3500
4800
5600
5000

20/18
20/18
20/18
20/18
20/18

208V
208Y/120V
480V
480V
480Y/277V

208/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

55.7
54.3
24.1
24.5
24.2

66.8
65.1
28.9
29.4
29.1

55.5
55.5
55.5
24.1
24.1

432
432
432
432
432

53.1
53.1
53.1
53.9
53.9

90
80
35
40
40

70
70
70
30
30

70
70
70
70
70

2
2
2
2
2

C
C
C
C
C

63.1
63.1
63.1
63.1
63.1

34.5
34.5
34.5
34.5
34.5

78.7
78.7
78.7
78.7
78.7

4319
4,089
4,389
4,619
4,549

6400
4700
6400
7400
6700

30/27
30/27
30/27
30/27
30/27

208V
208Y/120V
480V
480V
480Y/277V

208Y/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

83.5
81.4
36.2
36.7
36.4

100.2
97.7
43.4
44.1
43.6

83.3
83.3
83.3
36.1
36.1

432
432
432
432
432

79.6
79.6
79.6
80.8
80.8

125
125
60
60
60

110
110
110
50
50

100
100
100
110
110

3
3
3
3
3

D
D
D
D
D

99.1
99.1
99.1
99.1
99.1

34.5
34.5
34.5
34.5
34.5

78.7
78.7
78.7
78.7
78.7

6,509
6,079
6,509
6,774
6,609

9500
7000
9500
11100
10000

40/36
40/36
40/36
40/36
40/36

208V
208Y/120V
480V
480V
480Y/277V

208Y/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

111.3
108.5
48.2
49.0
48.5

133.6
130.2
57.9
58.8
58.2

111.0
111.0
111.0
48.1
48.1

432
432
432
432
432

106.2
106.2
106.2
107.8
107.8

175
175
70
80
80

150
150
150
70
70

150
150
150
150
150

3
3
3
3
3

E
E
E
E
E

103.1
103.1
103.1
103.1
103.1

34.5
34.5
34.5
34.5
34.5

78.7
78.7
78.7
78.7
78.7

7,953
7,519
7,969
8,239
8,059

12700
9300
12700
14700
13300

50/45
50/45
50/45
50/45
50/45

208V
208Y/120V
480V
480V
480Y/277V

208Y/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

147.1
143.4
63.7
65.4
65.4

176.5
172.0
76.5
78.4
78.4

138.8
138.8
138.8
60.1
60.1

432
432
432
432
432

132.7
132.7
132.7
136.1
136.1

225
225
100
100
100

175
175
175
80
80

175
175
175
175
175

3
3
3
3
3

F
F
F
F
F

106.4
106.4
106.4
106.4
106.4

34.3
34.3
34.3
34.3
34.3

78.7
78.7
78.7
78.7
78.7

9,621
9,041
9,451
9,861
9,861

25500
21000
25500
30100
30100

60/54
60/54
60/54
60/54
60/54

208V
208Y/120V
480V
480V
480Y/277V

208Y/120V
208Y/120V
208Y/120V
480Y/277V
480Y/277V

208V
208/120V
480V
480V
480/277V

170.6
166.4
73.9
75.1
74.3

204.8
199.7
88.7
90.1
89.2

166.5
166.5
166.5
72.2
72.2

432
432
432
432
432

159.3
159.3
159.3
161.7
161.7

250
250
110
110
110

225
225
225
100
100

200
200
200
225
225

3
3
3
3
3

F
F
F
F
F

106.4
106.4
106.4
106.4
106.4

34.3
34.3
34.3
34.3
34.3

78.7
78.7
78.7
78.7
78.7

9,599
9,041
9,601
10,167
10,173

23500
18300
23500
26600
24500

65/58
65/58
65/58
65/58

208V
480V
480V
480Y/277V

208Y/120V
480/277V
208Y/120V
480Y/277V

208V
480V
480V
480/277V

180.5
78.2
78.2
78.2

209.0
89.0
89.0
89.0

180.4
78.2
180.4
78.2

480
480
480
480

159.5
159.5
159.5
159.5

300
125
125
125

225
125
225
100

160
160
160
160

4
4
4
3

J
J
J
G

137
137
137
103.6

33.5
33.5
33.5
33.5

78.7
78.7
78.7
78.7

12,539
11,909
11,909
10,439

15683
15833
15683
15033

80/72
80/72
80/72
80/72

208V
480V
480V
480Y/277V

208Y/120V
480/277V
208Y/120V
480Y/277V

208V
480V
480V
480/277V

222.2
96.3
96.3
96.3

256.0
109.0
109.0
109.0

222.1
96.2
222.1
96.2

480
480
480
480

196.4
196.4
196.4
196.4

350
150
150
150

300
150
300
125

200
200
200
200

5
5
5
4

K
K
K
H

173
173
173
139.6

33.5
33.5
33.5
33.5

78.7
78.7
78.7
78.7

17,009
16,379
16,739
14,909

19300
19300
19300
18500

100/90
100/90
100/90
100/90

208V
480V
480V
480Y/277V

208Y/120V
480/277V
208Y/120V
480Y/277V

208V
480V
480V
480/277V

277.6
120.3
120.3
120.3

317.0
136.0
136.0
136.0

277.6
120.3
277.6
120.3

480
480
480
480

235.8
235.8
235.8
235.8

400
175
175
175

350
175
350
150

250
250
250
250

5
5
5
4

K
K
K
H

173
173
173
139.6

33.5
33.5
33.5
33.5

78.7
78.7
78.7
78.7

17,119
16,489
16,489
15,019

24120
24120
24120
23120

125/112
125/112
125/112
125/112

208V
480V
480V
480Y/277V

208Y/120V
480/277V
208Y/120V
480Y/277V

208V
480V
480V
480/277V

347.1
150.4
150.4
150.4

360.0
160.0
160.0
160.0

347.0
150.4
347.0
150.4

480
480
480
480

294.8
294.8
294.8
294.8

450
200
200
200

450
200
450
200

300
300
300
300

6
6
6
5

L
L
L
I

209
209
209
175.6

33.5
33.5
33.5
33.5

78.7
78.7
78.7
78.7

21,722
21,092
21,092
19,622

30150
30150
30150
28900

NOTES FOR SITE PLANNING DATA:

1. Input and bypass cables must be run in separate conduit from output cables.
2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors
are recommended. Neutral conductors to be sized for full capacity per NEC 310-15(B)(4)
References are per NEC 2008.
3. Wiring requirements:
AC Input: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground
AC Output: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground
4. All wiring is to be in accordance with national and local electrical codes.
5. Minimum cabinet access clearance: 3 ft. (0.9m) front, ; 18” (457mm) overhead for up to
65kVA systems and 24” (610mm) overhead for >65kVA systems; 8” (203mm) rear for up to
65kVA systems and 24”(610mm) rear for >65kVA systems.
6. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size
then replace.
7. Control wiring and power wiring must be run in separate conduit.

8. Dimensions are system dimensions including UPS, battery cabinets and transformer
cabinets (if any).; Transformer cabinets are front access
9. Weights are system weights including UPS, battery cabinets and transformer cabinets
(if any).; Transformer cabinets are front access.
10. Heat dissipation includes UPS , battery and transformer cabinet.
11. Recommended AC input external overcurrent protection is based on 80% rated
devices and maximum input current limit settings.

ADDITIONAL NOTES:

• If site configuration includes a back-up emergency generator, it is recommended

that the engine generator set be properly sized and equipped for
a UPS application. Generator options would typically include an
isochronous governor (generator frequency regulation) and a UPS
compatible regulator (generator voltage regulation). Consult generator
manufacturer for required generator options and sizing.

I N V E RT E R S

kVA/kW



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47
Instance ID                     : uuid:42a5b87d-fed4-c441-8cb3-d47fbea66105
Original Document ID            : adobe:docid:indd:a5474d74-47f3-11de-a5ae-b70cb1765cd9
Document ID                     : xmp.id:e458ef5e-e611-4eac-aefc-fa2e55aad84a
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6d75a830-30b2-42b7-b54b-1ce7dde97dbc
Derived From Document ID        : xmp.did:f39c9896-f718-479f-bbb3-8df7fa34ebd0
Derived From Original Document ID: adobe:docid:indd:a5474d74-47f3-11de-a5ae-b70cb1765cd9
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:08:10 13:20:44-04:00
Create Date                     : 2018:08:10 13:20:44-04:00
Modify Date                     : 2018:08:10 13:21:08-04:00
Metadata Date                   : 2018:08:10 13:21:08-04:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu