Page 1 of 19 EMC Test Report Report No.: AGC03307150201EE01 PRODUCT DESIGNATION : HDMI Extender by cat-5e/6 BRAND NAME : CE-LINK MODEL NAME : E30D CLIENT : CE LINK LIMITED DATE OF ISSUE : Feb.11,2015 STANDARD(S) : EN 55024:2010+AC:2011 REPORT VERSION : V1.0 EN 55022:2010+AC:2011 Attestation of Global Compliance (Shenzhen) Co., Ltd CAUTION: This report shall not be reproduced except in full without the written permission of the test laboratory and shall not be quoted out of context. Report No.: AGC03307150201EE01 Page 2 of 19 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Feb.11,2015 Valid Original Report Report No.: AGC03307150201EE01 Page 3 of 19 TABLE OF CONTENTS 1. VERIFICATION OF CONFORMITY ...................................................................................... 4 2. SYSTEM DESCRIPTION ...................................................................................................... 5 3. MEASUREMENT UNCERTAINTY........................................................................................ 5 4. PRODUCT INFORMATION .................................................................................................. 6 5. SUPPORT EQUIPMENT....................................................................................................... 7 6. TEST FACILITY .................................................................................................................... 8 7. EN 55022 RADIATED EMISSION TEST .............................................................................. 9 7.1. LIMITS OF RADIATED DISTURBANCES ...................................................................... 9 7.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 9 7.3. PROCEDURE OF RADIATED EMISSION TEST ......................................................... 10 7.4. TEST RESULT OF RADIATED EMISSION TEST ......................................................... 11 8. IEC 61000-4-2 ESD IMMUNITY TEST ................................................................................ 13 8.1. BLOCK DIAGRAM OF TEST SETUP .......................................................................... 13 8.2. TEST PROCEDURE .................................................................................................... 14 8.3. PERFORMANCE & RESULT ....................................................................................... 14 9. IEC 61000-4-3 RS IMMUNITY TEST .................................................................................. 15 9.1. BLOCK DIAGRAM OF TEST SETUP .......................................................................... 15 9.2. TEST PROCEDURE .................................................................................................... 16 9.3. PERFORMANCE & RESULT ....................................................................................... 16 APPENDIX A: PHOTOGRAPHS OF TEST SETUP ............................................................... 17 APPENDIX B: PHOTOGRAPHS OF EUT .............................................................................. 18 Report No.: AGC03307150201EE01 Page 4 of 19 1. VERIFICATION OF CONFORMITY Applicant CE LINK LIMITED Address Building G, Licheng Technology Industrial Zone, Gonghe Village, Shajing Town, Shenzhen City, China Manufacturer CE LINK LIMITED Address Building G, Licheng Technology Industrial Zone, Gonghe Village, Shajing Town, Shenzhen City, China Product Designation HDMI Extender by cat-5e/6 Brand Name CE-LINK Test Model E30D Date of test Feb.7~Feb.10, 2015 Deviation None Condition of Test Sample Normal Report Template AGCRT-EC-IT/DC(2013-03-01) The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. for compliance with the requirements set forth in the Technical Standards mentioned above. This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment and the level of the immunity endurance of the equipment are within the compliance requirements. The test results of this report relate only to the tested sample identified in this report. Prepared By Max Zhang Feb.11,2015 Kidd Yang Feb.11,2015 Solger Zhang Feb.11,2015 Checked By Authorized By Report No.: AGC03307150201EE01 Page 5 of 19 2. SYSTEM DESCRIPTION 1. Connect EUT and peripheral devices (if need) 2. Power on the EUT, The EUT begins to work. 3. Make sure the EUT works normally during the test. 3. MEASUREMENT UNCERTAINTY The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in measurement” (GUM) published by ISO. - Uncertainty of Radiated Emission, Uc = ±3.2 dB Report No.: AGC03307150201EE01 Page 6 of 19 4. PRODUCT INFORMATION Housing Type Plastic and metal EUT Rating Voltage DC 5V Supply By PC I/O Port Information ( Applicable Not Applicable) I/O Port of EUT I/O Port Type Q’TY Cable Tested with HDMI input port 1 0.25m, shielded 1 DDC output port 1 0 1 TMDS output port 1 0 1 Report No.: AGC03307150201EE01 Page 7 of 19 5. SUPPORT EQUIPMENT Device Type Manufacturer Model Name Serial No. Data Cable Power Cable PC Apple MB990CH/A N/A N/A N/A Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during emission test. Report No.: AGC03307150201EE01 Page 8 of 19 6. TEST FACILITY Site Location Attestation of Global Compliance (Shenzhen) Co., Ltd 2/F., Building 2, No.1-No.4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang, Bao'an District, Shenzhen, Guangdong, China TEST EQUIPMENT OF RADIATED EMISSION TEST Equipment Manufacturer Model S/N Cal. Date Cal. Due TEST RECEIVER R&S ESPI 101206 2014.07.25 2015.07.25 ANTENNA SCHWARZBE CK VULB9168 494 2014.08.17 2015.08.17 POSITIONING CONTROLLER MF MF-7802 MF780208285 -- -- TEST EQUIPMENT OF ESD TEST Equipment Manufacturer Model S/N Cal. Date Cal. Due ESD Simulator Schaffner NSG 438 782 2014.07.30 2015.07.30 TEST EQUIPMENT OF RS IMMUNITY TEST Description Manufacturer Model Identifier Cal. Date Cal. Due SIGNAL GENERATOR R&S E4421B 102525 2014.07.25 2015.07.25 ANTENNA SCHWARZBEC K VULB9168 VULB9168-494 2014.08.17 2015.08.17 POWER SENSOR R&S URV5-Z4 100124 2014.07.25 2015.07.25 POWER METER R&S NRVD 832378/027 2014.07.25 2015.07.25 POWER AMPLIFIER KALMUS 7100C N/A 2014.07.25 2015.07.25 RF AMPLIFIER Milmega AS01004-5 5_55 1004793 2014.07.25 2015.07.25 HORN ANTENNA ETS LINDGREN 3117 N/A 2013.08.17 2015.08.17 Report No.: AGC03307150201EE01 Page 9 of 19 7. EN 55022 RADIATED EMISSION TEST 7.1. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES Frequency (MHz) Distance (m) Maximum Field Strength Limit (dBuV/m Q.P.) 30-230 10 30.00 230-1000 10 37.00 Distance (m) Maximum Field Strength Limit (dBuV/m Q.P.) 30-230 3 40.00 230-1000 3 47.00 AT 3M DISTANCES Frequency (MHz) Note: The lower limit shall apply at the transition frequency. 7.2. BLOCK DIAGRAM OF TEST SETUP System Diagram of Connections between EUT and Simulators Report No.: AGC03307150201EE01 Page 10 of 19 7.3. PROCEDURE OF RADIATED EMISSION TEST (1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of the ground plane used).When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. (2) Support equipment, if needed, was placed as per EN 55022. (3) All I/O cables were positioned to simulate typical actual usage as per EN 55022. (4) The EUT was connected to PC and displayer. All support equipments received AC230V/50Hz power from socket under the turntable, if any. (5) The antenna was placed at 3 meter away from the EUT as stated in EN 55022. The antenna connected to the Analyzer via a cable and at times a pre-amplifier would be used. (6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. (7) The test mode(s) were scanned during the test: (8) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and Q.P./Peak reading is presented. Report No.: AGC03307150201EE01 Page 11 of 19 7.4. TEST RESULT OF RADIATED EMISSION TEST Radiated Emission Test at 3m Distance-Horizontal RESULT: PASS Report No.: AGC03307150201EE01 Page 12 of 19 Radiated Emission Test at 3m Distance-Vertical RESULT: PASS Report No.: AGC03307150201EE01 Page 13 of 19 8. IEC 61000-4-2 ESD IMMUNITY TEST ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST Port Enclosure Basic Standard IEC 61000-4-2 Test Level ± 8.0 kV (Air Discharge) ± 4.0 kV (Contact Discharge) ± 4.0 kV (Indirect Discharge) Standard require B Tester Max Temperature 20oC Humidity 50% 8.1. BLOCK DIAGRAM OF TEST SETUP (The 470 k ohm resistors are installed per standard requirement) VCP EUT& Support Units Support units HCP >1m Wooden Table 0.8m Ground Reference Plane Report No.: AGC03307150201EE01 Page 14 of 19 8.2. TEST PROCEDURE The EUT was located 0.1 m minimum from all side of the HCP. The support units were located 1 m minimum away from the EUT. EUT worked with resistance load, and make sure EUT worked normally. Active the communication function if the EUT with such port(s). As per the requirement of EN 55024; applying direct contact discharge at the sides other than front of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable, can’t be applied direct contact discharge side of EUT then the indirect discharge shall be applied. One of the test points shall be subjected to at least 50 indirect discharge (contact) to the front edge of horizontal coupling plane. Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate points of EUT for air discharge, a minimum of 10 single air discharges shall be applied. The application of ESD to the contact of open connectors is not required. Note: As per the A2 to IEC 61000-4-2, a bleed resistor cable is connected between the EUT and HCP during the test. The electrostatic discharges were applied as follows: Voltage Coupling Test Performance Result ±4kV Contact Discharge No function loss A ±4kV Indirect Discharge HCP (Front) No function loss A ±4kV Indirect Discharge HCP (Left) No function loss A ±4kV Indirect Discharge HCP (Back) No function loss A ±4kV Indirect Discharge HCP (Right) No function loss A ±4kV Indirect Discharge VCP (Front) No function loss A ±4kV Indirect Discharge VCP (Left) No function loss A ±4kV Indirect Discharge VCP (Back) No function loss A ±4kV Indirect Discharge VCP (Right) No function loss A ±8kV Air Discharge No function loss A 8.3. PERFORMANCE & RESULT The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the Criteria A: apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the Criteria B: manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Temporary loss of function is allowed, provided the functions self recoverable or can be Criteria C: restored by the operation of controls. PASS FAIL Report No.: AGC03307150201EE01 Page 15 of 19 9. IEC 61000-4-3 RS IMMUNITY TEST RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST Port Enclosure Basic Standard IEC 61000-4-3 Test Level: 3V/m with 80% AM. 1kHz Modulation. Standard require A Tester Max Temperature 25oC Humidity 55% 9.1. BLOCK DIAGRAM OF TEST SETUP Report No.: AGC03307150201EE01 Page 16 of 19 9.2. TEST PROCEDURE The EUT was located at the edge of supporting table keep 3 meter away from transmitting antenna, it just the calibrated square area of field uniformity. The support units were located outside of the uniformity area, but the cable(s) connected with EUT were exposed to the calibrated field as per IEC 61000-4-3. EUT worked with resistance load, and make sure EUT worked normally. Setting the testing parameters of RS test software per IEC 61000-4-3. Performing the test at each side of with specified level (3V/m) at 1% steps and test frequency from 80MHz to 1000MHz Recording the test result in following table. IEC 61000-4-3 Final test conditions: Test level: 3V/m Steps: 1 % of fundamental Dwell Time: 1 sec Range Field Modulation Polarity Position Test Performance Result (MHz) 80-1000 3V/m AM H Front No function loss A 80-1000 3V/m AM H Left No function loss A 80-1000 3V/m AM H Back No function loss A 80-1000 3V/m AM H Right No function loss A 80-1000 3V/m AM V Front No function loss A 80-1000 3V/m AM V Left No function loss A 80-1000 3V/m AM V Back No function loss A 80-1000 3V/m AM V Right No function loss A 9.3. PERFORMANCE & RESULT The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus Criteria A: is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the Criteria B: apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Temporary loss of function is allowed, provided the functions self recoverable or can be restored Criteria C: by the operation of controls. PASS FAIL Report No.: AGC03307150201EE01 Page 17 of 19 APPENDIX A: PHOTOGRAPHS OF TEST SETUP EN 55022 RADIATED EMISSION TEST SETUP IEC 61000-4-2 ESD IMMUNITY TEST SETUP Report No.: AGC03307150201EE01 Page 18 of 19 APPENDIX B: PHOTOGRAPHS OF EUT EXTERNAL VIEW OF EUT INTERNAL VIEW OF EUT-1 Report No.: AGC03307150201EE01 Page 19 of 19 INTERNAL VIEW OF EUT-2 -----END OF REPORT------
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2015:02:11 09:40:38+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2015:02:11 17:27:07+08:00 Metadata Date : 2015:02:11 17:27:07+08:00 Format : application/pdf Creator : dell Title : Microsoft Word - E30D_EMC Test Report_DC Document ID : uuid:76597364-54f5-473f-af25-885848861409 Instance ID : uuid:f7f63a19-85af-4ce0-a19e-89ca57fcf3da Page Count : 19 Author : dellEXIF Metadata provided by EXIF.tools