CE EMF Test Report

Report No. : EA471572

CE EMF Test Report
Equipment

: AC1200 Dual Band Concurrent Ceiling-Mount AP

Brand Name

: EDIMAX

Model No.

: EW-7476HPC, GAP-476HPC,CAP1200

Standard

: EN 62311:2008

Applicant
Manufacturer

: EDIMAX TECHNOLOGY CO., LTD.
No.3,Wu-Chuan 3rd Road,Wu-Ku Industrial Park,
New Taipei City, Taiwan

The product sample received on Jul. 15, 2014 and completely tested on Nov. 15, 2014. We,
SPORTON, would like to declare that the tested sample has been evaluated in accordance
with the procedures given in EN 62311:2008 and shown compliance with the applicable
technical standards. The equipment under R&TTE Directive 1999/5/EC of article 3.1a
harmonized essential for the EMF human exposure requirements.
The test results in this report apply exclusively to the tested model / sample. Without written
approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced except
in full.

Reviewed by:

Vic Hsiao / Supervisor

SPORTON INTERNATIONAL INC.

Page No.

: 1 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973

CE EMF Test Report

Report No. : EA471572

Table of Contents
1 

GENERAL DESCRIPTION .................................................................................................................... 5 

1.1 
1.2 
1.3 
1.4 
1.5 
1.6 
1.7 

Information.............................................................................................................................................. 5 
EUT General Information ....................................................................................................................... 5 
Evaluation Distance................................................................................................................................ 5 
Evaluation Method .................................................................................................................................. 6 
Basic Restrictions ................................................................................................................................... 6 
Reference Levels ................................................................................................................................... 6 
Compliance criteria................................................................................................................................. 6 

2 

ASSESSMENT RESULT ....................................................................................................................... 7 

2.1 
2.2 

Reference Levels Limits ......................................................................................................................... 7 
Reference Levels Evaluation.................................................................................................................. 7 

SPORTON INTERNATIONAL INC.

Page No.

: 2 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973

CE EMF Test Report

Report No. : EA471572

Summary of Test Result
EN 62311:2008 Harmonized Standard and Conformance Test Specifications
Report Ref. Std.
Clause Clause
2.2

4/6

Description
Basic Restrictions or Reference Levels

Limit

Result

Recommendation 1999/519/EC Complied
Table 1 Basic Restrictions
Table 2 Reference Levels

SPORTON INTERNATIONAL INC.

Page No.

: 3 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973

CE EMF Test Report

Report No. : EA471572

Revision History
Report No.

Version

Description

Issued Date

EA471572

Rev. 01

Initial issue of report

Jan. 07, 2015

SPORTON INTERNATIONAL INC.

Page No.

: 4 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973

CE EMF Test Report

Report No. : EA471572

1

General Description

1.1

Information

1.2

EUT General Information
RF General Information

1.3

Frequency Range (MHz)

Evaluation Mode

Application

2400-2483.5

2.4GHz WLAN

Wideband Data Transmission

5150-5250

5GHz WLAN

Wideband Data Transmission

Evaluation Distance
Evaluation Distance

Evaluation distance 20cm as a distance between the equipment and the operator or user when it is used
normally. The distance used for the assessment had be specified by the manufacturer and be consistent with
the intended usage of the equipment.
Evaluation Region
Far field region, r > (2*D^2/λ) (m)
Radiating near-field region, (2*D^2/λ) ≥ r > (λ/4) (m)
Reactive near-field region, (λ/4) ≥ r (m)
largest linear dimension = D (m), evaluation distance = r (m), wavelength = λ(m)

SPORTON INTERNATIONAL INC.

Page No.

: 5 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973

CE EMF Test Report

1.4

Report No. : EA471572

Evaluation Method
Evaluation Method

Far field region, For calculating the field in the far-field region the free space formula:
30  P  G
d
E = Electric field (V/m)
G = EUT Antenna numeric gain (numeric)
The formula can be changed to
Pd = 30  P  G

E (V/m) =

2
Power Density: Pd (W/m2) = E
377
P = RF output power (W)
d = Separation distance between radiator and human (m)

377  d 2

Radiating near-field region evaluation method:

SAR evaluation

alternative are E-field, H-field measurements

alternative either the synthetic model or cylindrical wave model.
The cylindrical wave model allows direct calculation of the power flux density, S, using:
P  180
S=
 D  r 
S = Power flux density W/m2
P = Power in watts radiated (W)
D = Length of antenna (m)
r = Distance in meters from the antenna
The cylindrical wave model is valid for a range of distances where rc (the distance at which the Cylinder and
far-field wave models give the same result) lies in the radiating near-field, and where the distance is less
than rc. At distances greater than rc the far field model (refer to the far-field calculation information in the
previous section) is more appropriate. Rc (m) – DG/2*δ/360
Reactive near-field region evaluation method:

SAR evaluation

1.5

Basic Restrictions

Restrictions on exposure to time-varying electric, magnetic, and electromagnetic fields which are based
directly on established health effects and biological considerations are termed “basic restrictions”. Depending
upon the frequency of the field, the physical quantities used to specify these restrictions are specific
absorption rate (SAR), and power density.

1.6

Reference Levels

Levels of field strength and currents that can be compared with corresponding measured or calculated values.
The reference levels are derived from the basic restrictions using worst-case assumptions about exposure. If
the reference levels are met, then the basic restrictions will be complied with, but if the reference levels are
exceeded, it does not necessarily mean that the basic restrictions will not be met.

1.7

Compliance criteria

If the average power emitted by apparatus operating in the frequency range 10 MHz – 300 GHz is less than or
equal to 20 mW and the transmitting peak power is less than 20 W then the apparatus is deemed to comply
with the basic restrictions without testing. The evaluation of power is only valid if it is made with an uncertainty
of less than 30 %.

SPORTON INTERNATIONAL INC.

Page No.

: 6 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973

CE EMF Test Report

Report No. : EA471572

2

Assessment Result

2.1

Reference Levels Limits

According to Council Recommendation 99/519/EC Annex III
Reference levels limits for electric, magnetic and electromagnetic fields (0 Hz to 300 GHz)

Frequency
range

E-field
strength
(V/m)

H-field
strength
(A/m)

B-field
(μT)

Equivalent plane
wave power
density
2
Seq (W/m )

0-1 Hz

-

3.2×104

4×104

-

4 2

4 2

1-8 Hz

10000

3.2×10 /f

4×10 /f

-

8-25 Hz

10000

4000/f

5000/f

-

0.025-0.8 kHz

250/f

4/f

5/f

-

0.8-3 kHz

250/f

5

6.25

-

3-150 kHz

87

5

6.25

-

0.15-1 MHz

87

0.73/f

0.92/f

-

1-10 MHz

87/f1/2

0.73/f

0.92/f

-

10-400 MHz

28

0.073

0.095

2

400-2000
MHz

1.375 f1/2

0.0037 f1/2

0.0046 f1/2

f/200

2-300 GHz

61

0.16

0.2

10

2.2

Reference Levels Evaluation
Evaluation Mode

RF Output
Power (dBm)

Gain (dBi)

EIRP Power
(dBm)

PD (S)

2.4GHz WLAN

17.08

2.82

19.90

0.19422

5GHz WLAN

18.94

4.00

22.94

0.39191

(W/m²)

10

Maximum Reference Level Limit (W/m²)

SPORTON INTERNATIONAL INC.

Page No.

: 7 of 7

TEL : 886-3-327-3456

Report Version

: Rev. 01

FAX : 886-3-327-0973



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Author                          : alicechen
Create Date                     : 2015:01:07 13:50:30+08:00
Modify Date                     : 2015:01:07 19:30:21+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:01:07 19:30:21+08:00
Format                          : application/pdf
Title                           : Microsoft Word - EA471572_EDIMAX_EN 62311 (MPE)
Creator                         : alicechen
Document ID                     : uuid:1b19f233-66f4-4079-95c1-f38caa11b670
Instance ID                     : uuid:4e154a67-704f-49c1-a6d6-c8a8b5874b5b
Page Count                      : 7
EXIF Metadata provided by EXIF.tools

Navigation menu