EA471572_EDIMAX_EN 62311 (MPE) EA471572 EDIMAX EN

2016-04-12

: Pdf Ea471572 Edimax En 62311 (Mpe) EA471572_EDIMAX_EN_62311_(MPE) CertsReports 525688 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 7

CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 1 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
CE EMF Test Report
Equipment : AC1200 Dual Band Concurrent Ceiling-Mount AP
Brand Name : EDIMAX
Model No. : EW-7476HPC, GAP-476HPC,CAP1200
Standard : EN 62311:2008
Applicant
Manufacturer : EDIMAX TECHNOLOGY CO., LTD.
No.3,Wu-Chuan 3rd Road,Wu-Ku Industrial Park,
New Taipei City, Taiwan
The product sample received on Jul. 15, 2014 and completely tested on Nov. 15, 2014. We,
SPORTON, would like to declare that the tested sample has been evaluated in accordance
with the procedures given in EN 62311:2008 and shown compliance with the applicable
technical standards. The equipment under R&TTE Directive 1999/5/EC of article 3.1a
harmonized essential for the EMF human exposure requirements.
The test results in this report apply exclusively to the tested model / sample. Without written
approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced except
in full.
Reviewed by:
Vic Hsiao / Supervisor
CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 2 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Table of Contents
1GENERAL DESCRIPTION .................................................................................................................... 5
1.1Information.............................................................................................................................................. 5
1.2EUT General Information ....................................................................................................................... 5
1.3Evaluation Distance ................................................................................................................................ 5
1.4Evaluation Method .................................................................................................................................. 6
1.5Basic Restrictions ................................................................................................................................... 6
1.6Reference Levels ................................................................................................................................... 6
1.7Compliance criteria ................................................................................................................................. 6
2ASSESSMENT RESULT ....................................................................................................................... 7
2.1Reference Levels Limits ......................................................................................................................... 7
2.2Reference Levels Evaluation.................................................................................................................. 7
CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 3 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Summary of Test Result
EN 62311:2008 Harmonized Standard and Conformance Test Specifications
Report
Clause Ref. Std.
Clause Description Limit Result
2.2 4/6 Basic Restrictions or Reference Levels Recommendation 1999/519/EC
Table 1 Basic Restrictions
Table 2 Reference Levels
Complied
CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 4 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
Revision History
Report No. Version Description Issued Date
EA471572 Rev. 01 Initial issue of report Jan. 07, 2015
CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 5 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
1 General Description
1.1 Information
1.2 EUT General Information
RF General Information
Frequency Range (MHz) Evaluation Mode Application
2400-2483.5 2.4GHz WLAN Wideband Data Transmission
5150-5250 5GHz WLAN Wideband Data Transmission
1.3 Evaluation Distance
Evaluation Distance
Evaluation distance 20cm as a distance between the equipment and the operator or user when it is used
normally. The distance used for the assessment had be specified by the manufacturer and be consistent with
the intended usage of the equipment.
Evaluation Region
Far field region, r > (2*D^2/λ) (m)
Radiating near-field region, (2*D^2/λ) r > (λ/4) (m)
Reactive near-field region, (λ/4) r (m)
largest linear dimension = D (m), evaluation distance = r (m), wavelength = λ(m)
CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 6 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
1.4 Evaluation Method
Evaluation Method
Far field region, For calculating the field in the far-field region the free space formula:
E (V/m) = d
GP30 Power Density: Pd (W/m2) = 377
E2
E = Electric field (V/m) P = RF output power (W)
G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human (m)
The formula can be changed to
Pd = 2
d377
GP30
Radiating near-field region evaluation method:
SAR evaluation
alternative are E-field, H-field measurements
alternative either the synthetic model or cylindrical wave model.
The cylindrical wave model allows direct calculation of the power flux density, S, using:
S =
rD
P180
S = Power flux density W/m2
P = Power in watts radiated (W)
D = Length of antenna (m)
r = Distance in meters from the antenna
The cylindrical wave model is valid for a range of distances where rc (the distance at which the Cylinder and
far-field wave models give the same result) lies in the radiating near-field, and where the distance is less
than rc. At distances greater than rc the far field model (refer to the far-field calculation information in the
previous section) is more appropriate. Rc (m) – DG/2*δ/360
Reactive near-field region evaluation method:
SAR evaluation
1.5 Basic Restrictions
Restrictions on exposure to time-varying electric, magnetic, and electromagnetic fields which are based
directly on established health effects and biological considerations are termed “basic restrictions”. Depending
upon the frequency of the field, the physical quantities used to specify these restrictions are specific
absorption rate (SAR), and power density.
1.6 Reference Levels
Levels of field strength and currents that can be compared with corresponding measured or calculated values.
The reference levels are derived from the basic restrictions using worst-case assumptions about exposure. If
the reference levels are met, then the basic restrictions will be complied with, but if the reference levels are
exceeded, it does not necessarily mean that the basic restrictions will not be met.
1.7 Compliance criteria
If the average power emitted by apparatus operating in the frequency range 10 MHz – 300 GHz is less than or
equal to 20 mW and the transmitting peak power is less than 20 W then the apparatus is deemed to comply
with the basic restrictions without testing. The evaluation of power is only valid if it is made with an uncertainty
of less than 30 %.
CE EMF Test Report Report No. : EA471572
SPORTON INTERNATIONAL INC. Page No. : 7 of 7
TEL : 886-3-327-3456 Report Version : Rev. 01
FAX : 886-3-327-0973
2 Assessment Result
2.1 Reference Levels Limits
According to Council Recommendation 99/519/EC Annex III
Reference levels limits for electric, magnetic and electromagnetic fields (0 Hz to 300 GHz)
Frequency
range
E-field
strength
(V/m)
H-field
strength
(A/m)
B-field
(μT)
Equivalent plane
wave power
density
Seq (W/m2)
0-1 Hz - 3.2×10
4
4×10
4
-
1-8 Hz 10000 3.2×10
4
/f
2
4×10
4
/f
2
-
8-25 Hz 10000 4000/f 5000/f -
0.025-0.8 kHz 250/f 4/f 5/f -
0.8-3 kHz 250/f 5 6.25 -
3-150 kHz 87 5 6.25 -
0.15-1 MHz 87 0.73/f 0.92/f -
1-10 MHz 87/f
1/2
0.73/f 0.92/f -
10-400 MHz 28 0.073 0.095 2
400-2000
MHz 1.375 f1/2 0.0037 f1/2 0.0046 f1/2 f/200
2-300 GHz 61 0.16 0.2 10
2.2 Reference Levels Evaluation
Evaluation Mode RF Output
Power (dBm) Gain (dBi) EIRP Power
(dBm) PD (S)
(W/m²)
2.4GHz WLAN 17.08 2.82 19.90 0.19422
5GHz WLAN 18.94 4.00 22.94 0.39191
Maximum Reference Level Limit (W/m²) 10