ELECTROMAGNETIC COMPLIANCE
TEST REPORT
For

16 Port Dump Gigabit switch&16 Port Web-Smart Gigabit switch
Model: RGS-1016WS, 524087, KN-S1016GM
Brand Name: Rapidmax

AG
C

Report No.: AGC10430912GZ06-1E1
Date of Issue: Jan.14, 2010
Prepared For

Rapidmax Technology Corporation

3F, 531 Chung-Cheng Rd. Hsin-Tien, Taipei231, Taiwan, R.O.C.
TEL: 886-2-2219-6000

FAX: 886-2-2218-8833
Prepared By

Attestation of Global Compliance Co., Ltd.

2F., No.2 Building, Huafeng No.1 Technical Industrial Park, Sanwei,
Xixiang, Baoan District, Shenzhen
TEL: 86-755-2908 1966

FAX: 86-755-2600 8484

Report No.: AGC10430912GZ06-1E1
Page 1 of 37

AG
C

TABLE OF CONTENTS
1. VERIFICATION OF CONFORMITY ...................................................................................... 3 
2. SYSTEM DESCRIPTION ...................................................................................................... 4 
3. PRODUCT INFORMATION .................................................................................................. 5 
4. SUPPORT EQUIPMENT....................................................................................................... 6 
5. TEST FACILITY .................................................................................................................... 7 
6. EN 55022 LINE CONDUCTED EMISSION TEST ................................................................. 8 
6.1. TEST EQUIPMENT OF CONDUCTED EMISSION TEST ................................................. 8 
6.2. LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................ 8 
6.3. BLOCK DIAGRAM OF TEST SETUP ................................................................................ 8 
6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST ................................................. 9 
6.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST .............................................. 10 
7. EN 55022 RADIATED EMISSION TEST ............................................................................ 12 
7.1. TEST EQUIPMENT OF RADIATED EMISSION TEST .................................................... 12 
7.2. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES ..................................... 12 
7.3. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 12 
7.4. PROCEDURE OF RADIATED EMISSION TEST ............................................................. 13 
7.5. TEST RESULT OF RADIATED EMISSION TEST ........................................................... 14 
8. EN 61000-3-2 POWER HARMONICS TEST ...................................................................... 16 
8.1. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 16 
8.2. LIMITS OF HARMONIC CURRENT ................................................................................. 17 
8.3. RESULT ........................................................................................................................... 17 
9. EN 61000-3-3 VOLTAGE FLUCTUATION / FLICKER TEST ............................................. 19 
9.1. TEST EQUIPMENT OF VOLTAGE FLUCTUATION / FLICKER TEST ............................ 19 
9.2. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 19 
9.3. RESULT ........................................................................................................................... 19 
10. IEC 61000-4-2 ESD IMMUNITY TEST .............................................................................. 21 
10.1. TEST EQUIPMENT OF ESD TEST ............................................................................... 21 
10.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 21 
10.3. TEST PROCEDURE ...................................................................................................... 21 
10.4. PERFORMANCE & RESULT ......................................................................................... 22 
11. IEC 61000-4-3 TEST ......................................................................................................... 23 
11.1. TEST EQUIPMENT ........................................................................................................ 23 
11.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 23 
11.3. TEST PROCEDURE ...................................................................................................... 24 

Report No.: AGC10430912GZ06-1E1
Page 2 of 37

11.4. PERFORMANCE & RESULT ......................................................................................... 25 
12. IEC 61000-4-4 TEST ......................................................................................................... 26 
12.1. TEST EQUIPMENT ........................................................................................................ 26 
12.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 26 
12.3. TEST PROCEDURE ...................................................................................................... 27 
12.4. PERFORMANCE & RESULT ......................................................................................... 27 
13. IEC 61000-4-5 SURGE IMMUNITY TEST ........................................................................ 28 
13.1. TEST EQUIPMENT OF SURGE TEST .......................................................................... 28 
13.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 28 
13.3. TEST PROCEDURE ...................................................................................................... 29 
13.4. PERFORMANCE & RESULT ......................................................................................... 29 

AG
C

14. IEC 61000-4-6 TEST ......................................................................................................... 30 
14.1. TEST EQUIPMENT ........................................................................................................ 30 
14.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 30 
14.3. TEST PROCEDURE ...................................................................................................... 31 
14.4. PERFORMANCE & RESULT ......................................................................................... 31 
15. IEC 61000-4-11 TEST ....................................................................................................... 32 
15.1. TEST EQUIPMENT ........................................................................................................ 32 
15.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 32 
15.3. TEST PROCEDURE ...................................................................................................... 33 
15.4. PERFORMANCE ........................................................................................................... 33 
APPENDIX 1 ........................................................................................................................... 34 
PHOTOGRAPHS OF TEST SETUP ....................................................................................... 34 
APPENDIX 2 ........................................................................................................................... 35 
PHOTOGRAPHS OF EUT ...................................................................................................... 35 

Report No.: AGC10430912GZ06-1E1
Page 3 of 37

1. VERIFICATION OF CONFORMITY
Equipment Under Test:
Brand Name:

16 Port Dump Gigabit switch &16 Port Web-Smart Gigabit switch
Rapidmax

Model:

RGS-1016WS, 524087, KN-S1016GM

Difference:

Only model name is different.
Rapidmax Technology Corporation

Applicant:

3F, 531 Chung-Cheng Rd. Hsin-Tien, Taipei231, Taiwan, R.O.C.

File Number:

Shenzhen Kingnet Electronic Co., Ltd
5/F, Block 4, Science & Technology Industrial Park of Private Enterprise
Pingshan, Xili Town, Nanshan District, Shenzhen
EMC Directive 2004/108/EC for CE Marking
EN 55022: 2006
EN 61000-3-2: 2006
EN 61000-3-3: 2008
EN 55024: 1998 + A1: 2001 + A2: 2003
(IEC 61000-4-2: 2008; IEC 61000-4-3: 2008; IEC 61000-4-4: 2004;
IEC 61000-4-5: 2005; IEC 61000-4-6: 2008; IEC 61000-4-11: 2004)
AGC10430912GZ06-1E1

Date of test:

Jan.06~ Jan.14, 2010

Deviation:

None

Condition of Test Sample:

Normal

Manufacturer:

AG
C

Type of Test:

Technical Standards:

The above equipment was tested by Attestation Of Global Compliance Co., Ltd. for compliance with the
requirements set forth in EMC Directive 2004/108/EC and the Technical Standards mentioned above. This
said equipment in the configuration described in this report shows the maximum emission levels emanating
from equipment and the level of the immunity endurance of the equipment are within the compliance
requirements.
The test results of this report relate only to the tested sample identified in this report.

Checked By

Jekey Zhang

Jan.14, 2010

King Zhang

Jan.14, 2010

Authorized By

Report No.: AGC10430912GZ06-1E1
Page 4 of 37

2. SYSTEM DESCRIPTION
EUT Test Procedure:
1. Connect EUT and peripheral devices (if need)
2. Power on the EUT, The EUT begins to work.

AG
C

3. Make sure the EUT works normally during the test.

Report No.: AGC10430912GZ06-1E1
Page 5 of 37

3. PRODUCT INFORMATION
Housing Type:

Metal

EUT Rating Voltage:

AC 100-240V

50Hz/60Hz

I/O Port Information (

Applicable

Not Applicable)

I/O Port of EUT
Q’TY

Cable

Tested with

AC INPUT PORT

1

1

1

DC OUTPUT PORT

1

1

1

AG
C

I/O Port Type

Report No.: AGC10430912GZ06-1E1
Page 6 of 37

4. SUPPORT EQUIPMENT
Device Type

Manufacturer

Model Name

Serial No.

Data Cable

Power
Cable

--

--

--

--

--

--

**Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during
emission test.

AG
C

Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended
use.

Report No.: AGC10430912GZ06-1E1
Page 7 of 37

5. TEST FACILITY

Location:

F1, Bldg.A, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,
Nanshan District, 518057 Shenzhen, P.R. China

Description:

There is one 3m semi-anechoic an area test sites and two line conducted labs for final
test. The Open Area Test Sites and the Line Conducted labs are constructed and
calibrated to meet the FCC requirements in documents ANSI C63.4 and CISPR

AG
C

22/EN 55022 requirements.

Site Filing:

The site description is on file with the Federal Communications Commission, 7435
Oakland Mills Road, Columbia, MD 21046.

Instrument Tolerance:

All measuring equipment is in accord with ANSI C63.4 and CISPR 22 requirements
that meet industry regulatory agency and accreditation agency requirement.

Report No.: AGC10430912GZ06-1E1
Page 8 of 37

6. EN 55022 LINE CONDUCTED EMISSION TEST
6.1. TEST EQUIPMENT OF CONDUCTED EMISSION TEST
Description
Manufacturer
Model
Spectrum Analyzer
Agilent
E4440A
LISN

ETS

Identifier
N/A

Cal. Date
06/29/2009

Cal. Due
06/28/2010

N/A

06/29/2009

06/28/2010

3816

6.2. LIMITS OF LINE CONDUCTED EMISSION TEST
Maximum RF Line Voltage
Q.P.( dBuV)
Average( dBuV)

Frequency

66-56

56-46

500kHz-5MHz

56

46

5MHz-30MHz

60

50

AG
C

150kHz-500kHz

**Note: 1. The lower limit shall apply at the transition frequency.

2.The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz

6.3. BLOCK DIAGRAM OF TEST SETUP

S h ie ld e d

R o o m

F ilte r

0 .4 m

E U T

T o

M e a s u r in g

E q u ip m e n t

0 .8 m

L IS N

P o w e

A : P o w e re d

th ro u g h

filte r

Report No.: AGC10430912GZ06-1E1
Page 9 of 37

6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST
The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
placed on the ground plane as per EN55022 (see Test Facility for the dimensions of the ground plane
used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
mm non-conductive covering to insulate the EUT from the ground plane.
2) Support equipment, if needed, was placed as per EN55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN55022.
4) The EUT received AC100-240V/50Hz/60Hz power through a Line Impedance Stabilization Network (LISN)
which supplied power source and was grounded to the ground plane.
5) All support equipments received power from a second LISN supplying power of AC 230V/50Hz, if any.
6) The EUT test program was started. Emissions were measured on each current carrying line of the EUT
using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
7) Analyzer / Receiver scanned from 150 kHz to 30 MHz for emissions in each of the test modes.
8) During the above scans, the emissions were maximized by cable manipulation.
9) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
10) Emission frequency and amplitude were recorded into a computer in which correction factors were used to
calculate the emission level and compare reading to the applicable limit. If EUT emission level was
less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
detector.

AG
C

1)

The test data of the worst case condition(s) was reported on the Summary Data page.

Report No.: AGC10430912GZ06-1E1
Page 10 of 37

6.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST

AG
C

Test Result of Line Conducted Emission Test-Neutral Line

Report No.: AGC10430912GZ06-1E1
Page 11 of 37

AG
C

Test Result of Line Conducted Emission Test-Line Line



Report No.: AGC10430912GZ06-1E1
Page 12 of 37

7. EN 55022 RADIATED EMISSION TEST
7.1. TEST EQUIPMENT OF RADIATED EMISSION TEST
Description
Manufacturer
Model
Spectrum Analyzer
Agilent
E4443A

Identifier
N/A

Cal. Date
06/29/2009

Cal. Due
06/28/2010

Biconilog Antenna

ETS

3142C

N/A

06/29/2009

06/28/2010

Multi_device Controller

ETS

2090

N/A

06/29/2009

06/28/2010

7.2. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES
Frequency
(MHz)

Distance
(m)

Maximum Field Strength Limit

30-230

10

30.00

230-1000

10

37.00

AG
C

(dBuV/m Q.P.)

**Note: The lower limit shall apply at the transition frequency.

7.3. BLOCK DIAGRAM OF TEST SETUP

1-4m

EUT

0.8 m

10m

Amplifier

Spectrum

Analyzer

Report No.: AGC10430912GZ06-1E1
Page 13 of 37

7.4. PROCEDURE OF RADIATED EMISSION TEST

AG
C

1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which
is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of the ground plane
used).When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm
non-conductive covering to insulate the EUT from the ground plane.
2) Support equipment, if needed, was placed as per EN 55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN 55022.
4) The EUT received AC100-240V/50Hz/60Hz power through the outlet socket under the turntable. All support
equipments received AC230V/50Hz power from socket under the turntable, if any.
5) The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna connected to
the Analyzer via a cable and at times a pre-amplifier would be used.
6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was started.
Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to
4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the
emission reading level.
7) The test mode(s) were scanned during the test:
8) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization
and turntable position were recorded into a computer in which correction factors were used to calculate the
emission level and compare reading to the applicable limit and Q.P./Peak reading is presented.

Report No.: AGC10430912GZ06-1E1
Page 14 of 37

AG
C

7.5. TEST RESULT OF RADIATED EMISSION TEST

AG
C

Report No.: AGC10430912GZ06-1E1
Page 15 of 37

Report No.: AGC10430912GZ06-1E1
Page 16 of 37

8. EN 61000-3-2 POWER HARMONICS TEST
POWER HARMONICS MEASUREMENT
Port :

AC mains

Basic Standard:
Limits:

EN 61000-3-2 :2006
CLASS A ;
CLASS B;

Tester:

Sky

Temperature:

25oC

Humidity:

55%

CLASS C;

CLASS D

AG
C

8.1. BLOCK DIAGRAM OF TEST SETUP
Harmonics & Flicker
Analyzer
+

Power cord

Power Source

EUT

0.8m

Support Units

Report No.: AGC10430912GZ06-1E1
Page 17 of 37

8.2. LIMITS OF HARMONIC CURRENT
Limits for Class A Equipment
Harmonics Order n

Max. permissible harmonic current (A)
Odd harmonics

3

2.30

5

1.14

7

0.77

9

0.40

11

0.33

13

0.21

15≤n≤39

0.15×15/n
Even harmonics
1.08

4

0.43

6

0.30

8≤n≤40

0.23×8/n

AG
C

2

NOTE:

1. According to section 5 of EN61000-3-2: 2006, the EUT is Class A equipment.
2. The above limits are for all applications having an active input power>75W.
with an active input power up to and including 75W.

8.3. RESULT

No limits apply for equipment

Report No.: AGC10430912GZ06-1E1
Page 18 of 37

Harmonics Current
(A)
0.025
0.018
0.017
0.015
0.012
0.010
0.008
0.006
0.006
0.005
0.004
0.003
0.003
0.002
0.002
0.002
0.002
0.001
0.000
0.000

Limit (A)
---------------------

Harmonics
Order
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

Harmonics Current
(A)
0.001
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Limit (A)
---------------------

AG
C

Test Result
Harmonics
Order
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
NOTE:

1. The active input power of the EUT is 15 W.

2. No limits apply for equipment with an active input power up to and including 75W.

Report No.: AGC10430912GZ06-1E1
Page 19 of 37

9. EN 61000-3-3 VOLTAGE FLUCTUATION / FLICKER TEST
VOLTAGE FLUCTUATION/FLICKER MEASUREMENT
Port :

AC mains

Basic Standard:

EN 61000-3-3 :2008

Limits:

§5 of EN 61000-3-3

Tester:

Sky

Temperature:

25oC

Humidity:

55%

Cal. Date

Cal. Due

06/29/2009

06/28/2010

AG
C

9.1. TEST EQUIPMENT OF VOLTAGE FLUCTUATION / FLICKER TEST
Description
Manufacturer
Model
Identifier
California
500LIX-400-C
Harmonic Emission Flicker
N/A
instruments
TS
9.2. BLOCK DIAGRAM OF TEST SETUP
Harmonics & Flicker
Analyzer
+

Power cord

Power Source

EUT

0.8m

9.3. RESULT

Support Units

Report No.: AGC10430912GZ06-1E1
Page 20 of 37

Flicker Test Summary per EN/IEC61000-3-3 (Run time)
EUT: 16 Port Dump Gigabit switch &16 Port Web-Smart Gigabit switch

Tested by: Sky

Test category: All parameters (European limits)

Test Margin: 100

Test date: 2010-01-14

End time: 11:12:15

Start time: 11:02:15

Test duration (min): 10
Comment: On
Customer: Rapidmax Technology Corporation

Test Result: Pass

Status: Test Completed

Psti and limit line

AG
C

European Limits

1.00

Pst

0.75
0.50
0.25
0.00

11:12:15

Time is too short for Plt plot

Parameter values recorded during the test:
Vrms at the end of test (Volt):

229.78

Highest dt (%):

-0.13

Time(mS) > dt:

0.0

Highest dc (%):

0.00

Highest dmax (%):

0.08

Test limit (%):

3.30

Pass

500.0

Pass

Test limit (%):

3.30

Pass

Test limit (%):

4.00

Pass

1.000

Pass

Test limit (mS):

Highest Pst (10 min. period):

0.004

Test limit:

Highest Plt (2 hr. period):

0.002

Test limit:

0.650

Pass

Report No.: AGC10430912GZ06-1E1
Page 21 of 37

10. IEC 61000-4-2 ESD IMMUNITY TEST
ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST
Port :
Basic Standard:

Enclosure
IEC 61000-4-2: 2008

Test Level:

± 8.0 kV (Air Discharge)
± 4.0 kV (Contact Discharge)
± 4.0 kV (Indirect Discharge)
B

Tester:

Sky

Temperature:

20oC

Humidity:

50%

AG
C

Standard require:

10.1. TEST EQUIPMENT OF ESD TEST
Description
Manufacturer
ESD System
HAEFELY

Model
PESD 1610

Identifier
N/A

Cal. Date
06/29/2009

Cal. Due
06/28/2010

10.2. BLOCK DIAGRAM OF TEST SETUP

(The 470 k ohm resistors are installed per standard requirement)

VCP

EUT&
Support
Units

Support units

HCP

>1m

Wooden Table

0.8m

Ground Reference Plane

10.3. TEST PROCEDURE

The EUT was located 0.1 m minimum from all side of the HCP.

The support units were located 1 m minimum away from the EUT.

EUT worked with resistance load, and make sure EUT worked normally.
Active the communication function if the EUT with such port(s).

As per the requirement of EN 55024; applying direct contact discharge at a minimum four points of the EUT

Report No.: AGC10430912GZ06-1E1
Page 22 of 37

at minimum 200 discharges (100 positive and 100 negative) if applicable, one of the test points shall be
subjected to at least 50 indirect discharges(contact) to the centre of the front edge of the horizontal coupling
plane. The remaining three test points shall each receive at least 50 direct contact discharges. If no direct
contact test points available, then at least 200 indirect discharges shall be applied in the indirect mode. Tests
shall be performed at a maximum repetition rate of one discharge per second.
Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate points of
EUT for air discharge, a minimum of 10 single air discharges shall be applied.
The application of ESD to the contact of open connectors is not required.
The following test condition was followed during the tests.
Note: As per the A2 to IEC 61000-4-2, a bleed resistor cable is connected between the EUT and HCP during the test.

The electrostatic discharges were applied as follows:

AG
C

Amount of
Discharges
Mini 150 /Point
Mini 50 /Point
Mini 50 /Point
Mini 50/Point
Mini 50 /Point
Mini 10 /Point

Voltage

Coupling

Result (Pass/Fail)

±2kV; ±4kV
±2kV; ±4kV
±2kV; ±4kV
±2kV; ±4kV
±2kV; ±4kV
±2kV; ±4kV; ±8kV

Contact Discharge
Indirect Discharge HCP (Front)
Indirect Discharge VCP (Left)
Indirect Discharge VCP (Back)
Indirect Discharge VCP (Right)
Air Discharge

Pass
Pass
Pass
Pass
Pass
Pass

10.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B:

The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.

PASS

FAIL

Report No.: AGC10430912GZ06-1E1
Page 23 of 37

11. IEC 61000-4-3 TEST
RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST
Port :

Enclosure

Basic Standard:

IEC 61000-4-3:2008

Test Level:

3V/m with 80% AM. 1kHz Modulation.

Standard require:

A

Tester:

Sky

Temperature:

25oC

Humidity:

55%

Manufacturer
IFA
AR

Model
2023B
150W1000

Identifier
N/A
N/A

Cal. Date
06/29/2009
06/29/2009

Cal. Due
06/28/2010
06/28/2010

AR

25S1G4A

N/A

06/29/2009

06/28/2010

AG
C

11.1. TEST EQUIPMENT
Description
Signal Generator
Power Amplifier
Power Antenna

11.2. BLOCK DIAGRAM OF TEST SETUP

3 meter

7X4X3 Chamber

EUT &Support Units

0.8m

1.5 meter

Power Amp

Signal

Generator

EUT Monitoring by using
a camera

PC Controller to control
S.G. & PA as

Control Room

Report No.: AGC10430912GZ06-1E1
Page 24 of 37

11.3. TEST PROCEDURE
The EUT was located at the edge of supporting table keep 3 meter away from transmitting antenna, it just
the calibrated square area of field uniformity. The support units were located outside of the uniformity area, but
the cable(s) connected with EUT were exposed to the calibrated field as per IEC 61000-4-3.
EUT worked with resistance load, and make sure EUT worked normally.
Setting the testing parameters of RS test software per IEC 61000-4-3.
Performing the test at each side of with specified level (3V/m) at 1% steps and test frequency from 80MHz
to 1000MHz
Recording the test result in following table.
IEC 61000-4-3 Final test conditions:
Test level: 3V/m

AG
C

Steps: 1 % of fundamental
Dwell Time: 1 sec
Range (MHz)

Field

Modulation

Polarity

Position

Result (Pass/Fail)

80-1000

3V/m

AM

H

Front

Pass

80-1000

3V/m

AM

H

Left

Pass

80-1000

3V/m

AM

H

Back

Pass

80-1000

3V/m

AM

H

Right

Pass

80-1000

3V/m

AM

V

Front

Pass

80-1000

3V/m

AM

V

Left

Pass

80-1000

3V/m

AM

V

Back

Pass

80-1000

3V/m

AM

V

Right

Pass

Report No.: AGC10430912GZ06-1E1
Page 25 of 37

11.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.

AG
C

Criteria B:

PASS

FAIL

Report No.: AGC10430912GZ06-1E1
Page 26 of 37

12. IEC 61000-4-4 TEST
ELECTRICAL FAST TRANSIENTS/BURST IMMUNITY TEST
Port :

On Power Supply Lines

Basic Standard:

IEC 61000-4-4:2004

Test Level:

+/- 1kV for Power Supply Lines

Standard require:

B

Tester:

Sky

Temperature:

25oC

Humidity:

55%

AG
C

12.1. TEST EQUIPMENT
Description
Compact Generator
Capacitive Clamp
CDN for Telecom Port

Manufacturer
EM-Test
EM-Test
EM-Test

Model
UCS500M/6B
C Clamp HFK
CNV504S1

Identifier
N/A
N/A
N/A

Cal. Date
06/29/2009
06/29/2009
06/29/2009

Cal. Due
06/28/2010
06/28/2010
06/28/2010

12.2. BLOCK DIAGRAM OF TEST SETUP

EUT

AC

Line

EFT/Burst/Surge
Generator

Controller Computer

80cm

Support Units

Non-Conductive Table

Report No.: AGC10430912GZ06-1E1
Page 27 of 37

12.3. TEST PROCEDURE
The EUT and support units were located on a wooden table 0.8m away from ground reference plane.
A 1.0 meter long power cord was attached to EUT during the test.
The length of communication cable between communication port and clamp was keeping within 1 meter.
EUT worked with resistance load, and make sure EUT worked normally.
Related peripherals work during the test.
Recording the test result as shown in following table.
Test conditions:
Impulse Frequency: 5 kHz
Tr/Th: 5/50ns
Burst Duration: 15ms
Burst Period: 300ms
Voltage kV
+1
-1

Inject Method
Direct
Direct

Result (Pass/Fail)
Pass
Pass

AG
C

Inject Line
L+N
L+N

12.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B:

The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.

PASS

FAIL

Report No.: AGC10430912GZ06-1E1
Page 28 of 37

13. IEC 61000-4-5 SURGE IMMUNITY TEST
SURGE IMMUNITY TEST
Port :

On Power Supply Lines

Basic Standard:

IEC 61000-4-5:2005
+/- 1kV (Line to Line)

Requirements :

+/- 2kV (Line to Ground)
B

Tester:

Sky

Temperature:

25oC

Humidity:

55%

AG
C

Standard require:

13.1. TEST EQUIPMENT OF SURGE TEST
Description
Compact Generator
Capacitive Clamp
CDN for Telecom Port

Manufacturer
EM-Test
EM-Test
EM-Test

Model
UCS500M/6B
C Clamp HFK
CNV504S1

Identifier
N/A
N/A
N/A

Cal. Date
06/29/2009
06/29/2009
06/29/2009

13.2. BLOCK DIAGRAM OF TEST SETUP

To AC

Surge Immunity Test

EUT

Source

&

Support Units

80 cm

Controller Computer

Cal. Due
06/28/2010
06/28/2010
06/28/2010

Report No.: AGC10430912GZ06-1E1
Page 29 of 37

13.3. TEST PROCEDURE
The EUT and support units were located on a wooden table 0.8 m away from ground floor.
EUT worked with resistance load, and make sure EUT worked normally.
Recording the test result as shown in following table.
Test conditions:
Voltage Waveform:
Current Waveform:
Polarity:
Phase angle:
Number of Test:

Voltage (kV)
1
1

Polarity
Positive
Negative

Coupling Method
Capacitive
Capacitive

Result (Pass/Fail)
Pass
Pass

AG
C

Coupling Line
L1-L2
L1-L2

1.2/50 us
8/20 us
Positive/Negative
0o, 90o, 270o
5

13.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B:

The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by the
manufacturer, when the apparatus is used as intended. In some cases the performance level
may be replaced by a permissible loss of performance. During the test, degradation of
performance is however allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.

PASS

FAIL

Report No.: AGC10430912GZ06-1E1
Page 30 of 37

14. IEC 61000-4-6 TEST
IEC 61000-4-6 IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY
FIELD
Port :

On Power Supply Lines

Basic Standard:

IEC 61000-4-6: 2008

Requirements :

3V with 80% AM. 1 kHz Modulation

Standard require:

A

Tester:

Sky

Temperature:

25oC

Humidity:

55%

AG
C

14.1. TEST EQUIPMENT
Description
Power Amplifier
CDN

Manufacturer
AR
EM-Test

Model
75A250A
N/A

Identifier
N/A
N/A

Cal. Date
06/29/2009
06/29/2009

Cal. Due
06/28/2010
06/28/2010

Direction Coupler

EM-Test

DC2600N

N/A

06/29/2009

06/28/2010

EM-Clamp

EM-Test

EM101

N/A

06/29/2009

06/28/2010

Caliberation

EM-Test

CAM2/M3

N/A

06/29/2009

06/28/2010

Attenuator

EM-Test

ATT6/75

N/A

06/29/2009

06/28/2010

Power Sensor

AR

PH2000

N/A

06/29/2009

06/28/2010

Power Meter

AR

PM2002

N/A

06/29/2009

06/28/2010

Signal Generator

IFA

2023B

N/A

06/29/2009

06/28/2010

14.2. BLOCK DIAGRAM OF TEST SETUP

PC

Controller

Power

0.1m< L <0.3m

Amplifier

10 cm isolation supporter

EUT and
Support units

CDN

Ground Reference Plane

Report No.: AGC10430912GZ06-1E1
Page 31 of 37

14.3. TEST PROCEDURE
The EUT and support units were located at a ground reference plane with the interposition of a 0.1 m
thickness insulating support and the CDN was located on GRP directly.
EUT worked with resistance load, and make sure EUT worked normally.
Related peripherals work during the test.
Setting the testing parameters of CS test software per IEC 61000-4-6.
Recording the test result in following table.
Test conditions:
0.15MHz-80MHz

Frequency Step:

1% of fundamental

Dwell Time:

1 sec

AG
C

Frequency Range:

Range (MHz)

Strength

Modulation

Result (Pass/Fail)

0.15-80

3V

AM

Pass

14.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B:

The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.

PASS

FAIL

Report No.: AGC10430912GZ06-1E1
Page 32 of 37

15. IEC 61000-4-11 TEST
VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST
Port :

On Power Supply Lines

Basic Standard:

IEC 61000-4-11: 2004

Requirements :

0, 45, 90, 135, 180, 225, 270, 315 degrees

Test Interval:

Min. 10 sec.

Tester:

Sky

Temperature:

25oC

Humidity:

55%
Reduction
(%)
>95
30

Duration
( periods )
0.5
25

Performance
Criteria
B
C

Voltage Interruptions

Test Level
% UT
<5

Reduction
(%)
>95

Duration
( periods )
250

Performance
Criteria
C

AG
C

Voltage Dips

Test Level
% UT
<5
70

15.1. TEST EQUIPMENT

Description
Compact Generator
Capacitive Clamp
CDN for Telecom Port

Manufacturer
EM-Test
EM-Test
EM-Test

Model
UCS500M/6B
C Clamp HFK
CNV504S1

Identifier
N/A
N/A
N/A

Cal. Date
06/29/2009
06/29/2009
06/29/2009

15.2. BLOCK DIAGRAM OF TEST SETUP
To AC

Source

Dips/Interruption and

EUT

Variations Simulator

&

Support Units

80 cm

Controller Computer

Cal. Due
06/28/2010
06/28/2010
06/28/2010

Report No.: AGC10430912GZ06-1E1
Page 33 of 37

15.3. TEST PROCEDURE
The EUT and support units were located on a wooden table, 0.8 m away from ground floor.
EUT worked with resistance load, and make sure EUT worked normally.
Setting the parameter of tests and then perform the test software of test simulator.
Conditions changes to occur at 0 degree crossover point of the voltage waveform.
Recording the test result in test record form.
Test conditions:
The duration with a sequence of three dips/interruptions with interval of 10 s minimum
(Between each test event)
Voltage Dips:
Reduction
(%)
>95
30

Duration
( periods)
0.5
25

Voltage Interruptions:
Test Level
Reduction
% UT
(%)
<5
>95

Duration
( periods)
250

Observation
Normal
Normal

Meet Performance
Criteria
B
C

AG
C

Test Level
% UT
<5
70

Observation
Normal

Meet Performance
Criteria
C

15.4. PERFORMANCE
Criteria A:

The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.

Criteria B:

The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.

Criteria C:

Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.

PASS

FAIL

Report No.: AGC10430912GZ06-1E1
Page 34 of 37

APPENDIX 1
PHOTOGRAPHS OF TEST SETUP

AG
C

EN 55022 LINE CONDUCTED EMISSION TEST SETUP

IEC 61000-4-2 ELECTROSTATIC DISCHARGE TEST SETUP

Report No.: AGC10430912GZ06-1E1
Page 35 of 37

APPENDIX 2
PHOTOGRAPHS OF EUT

AG
C

TOP VIEW OF EUT

BOTTOM VIEW OF EUT

Report No.: AGC10430912GZ06-1E1
Page 36 of 37

AG
C

LEFT VIEW OF EUT

RIGHT VIEW OF EUT

Report No.: AGC10430912GZ06-1E1
Page 37 of 37

AG
C

BACK VIEW OF EUT

FRONT VIEW OF EUT

-----END OF REPORT-----



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2010:01:18 08:51:01+08:00
Create Date                     : 2010:01:18 08:48:57+08:00
Metadata Date                   : 2010:01:18 08:51:01+08:00
Format                          : application/pdf
Title                           : Microsoft Word - EMC Test Report_RGS-1016WS
Creator                         : ANNA
Document ID                     : uuid:35ad722b-1f77-4b12-8147-3932d190f3b4
Instance ID                     : uuid:70ef5593-f7df-46eb-980c-1c792cffc883
Page Count                      : 38
Author                          : ANNA
EXIF Metadata provided by EXIF.tools

Navigation menu