EMC Report_RGS 1016WS Report RGS
Emc Report Rgs-1016Ws EMC__Report_RGS-1016WS EMC__Report_RGS-1016WS CertsReports 524087 ProductFiles assets.mhint
2016-04-11
: Pdf Emc Report Rgs-1016Ws EMC__Report_RGS-1016WS CertsReports 524148 ProductFiles
Open the PDF directly: View PDF .
Page Count: 38
Download | |
Open PDF In Browser | View PDF |
ELECTROMAGNETIC COMPLIANCE TEST REPORT For 16 Port Dump Gigabit switch&16 Port Web-Smart Gigabit switch Model: RGS-1016WS, 524087, KN-S1016GM Brand Name: Rapidmax AG C Report No.: AGC10430912GZ06-1E1 Date of Issue: Jan.14, 2010 Prepared For Rapidmax Technology Corporation 3F, 531 Chung-Cheng Rd. Hsin-Tien, Taipei231, Taiwan, R.O.C. TEL: 886-2-2219-6000 FAX: 886-2-2218-8833 Prepared By Attestation of Global Compliance Co., Ltd. 2F., No.2 Building, Huafeng No.1 Technical Industrial Park, Sanwei, Xixiang, Baoan District, Shenzhen TEL: 86-755-2908 1966 FAX: 86-755-2600 8484 Report No.: AGC10430912GZ06-1E1 Page 1 of 37 AG C TABLE OF CONTENTS 1. VERIFICATION OF CONFORMITY ...................................................................................... 3 2. SYSTEM DESCRIPTION ...................................................................................................... 4 3. PRODUCT INFORMATION .................................................................................................. 5 4. SUPPORT EQUIPMENT....................................................................................................... 6 5. TEST FACILITY .................................................................................................................... 7 6. EN 55022 LINE CONDUCTED EMISSION TEST ................................................................. 8 6.1. TEST EQUIPMENT OF CONDUCTED EMISSION TEST ................................................. 8 6.2. LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................ 8 6.3. BLOCK DIAGRAM OF TEST SETUP ................................................................................ 8 6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST ................................................. 9 6.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST .............................................. 10 7. EN 55022 RADIATED EMISSION TEST ............................................................................ 12 7.1. TEST EQUIPMENT OF RADIATED EMISSION TEST .................................................... 12 7.2. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES ..................................... 12 7.3. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 12 7.4. PROCEDURE OF RADIATED EMISSION TEST ............................................................. 13 7.5. TEST RESULT OF RADIATED EMISSION TEST ........................................................... 14 8. EN 61000-3-2 POWER HARMONICS TEST ...................................................................... 16 8.1. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 16 8.2. LIMITS OF HARMONIC CURRENT ................................................................................. 17 8.3. RESULT ........................................................................................................................... 17 9. EN 61000-3-3 VOLTAGE FLUCTUATION / FLICKER TEST ............................................. 19 9.1. TEST EQUIPMENT OF VOLTAGE FLUCTUATION / FLICKER TEST ............................ 19 9.2. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 19 9.3. RESULT ........................................................................................................................... 19 10. IEC 61000-4-2 ESD IMMUNITY TEST .............................................................................. 21 10.1. TEST EQUIPMENT OF ESD TEST ............................................................................... 21 10.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 21 10.3. TEST PROCEDURE ...................................................................................................... 21 10.4. PERFORMANCE & RESULT ......................................................................................... 22 11. IEC 61000-4-3 TEST ......................................................................................................... 23 11.1. TEST EQUIPMENT ........................................................................................................ 23 11.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 23 11.3. TEST PROCEDURE ...................................................................................................... 24 Report No.: AGC10430912GZ06-1E1 Page 2 of 37 11.4. PERFORMANCE & RESULT ......................................................................................... 25 12. IEC 61000-4-4 TEST ......................................................................................................... 26 12.1. TEST EQUIPMENT ........................................................................................................ 26 12.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 26 12.3. TEST PROCEDURE ...................................................................................................... 27 12.4. PERFORMANCE & RESULT ......................................................................................... 27 13. IEC 61000-4-5 SURGE IMMUNITY TEST ........................................................................ 28 13.1. TEST EQUIPMENT OF SURGE TEST .......................................................................... 28 13.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 28 13.3. TEST PROCEDURE ...................................................................................................... 29 13.4. PERFORMANCE & RESULT ......................................................................................... 29 AG C 14. IEC 61000-4-6 TEST ......................................................................................................... 30 14.1. TEST EQUIPMENT ........................................................................................................ 30 14.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 30 14.3. TEST PROCEDURE ...................................................................................................... 31 14.4. PERFORMANCE & RESULT ......................................................................................... 31 15. IEC 61000-4-11 TEST ....................................................................................................... 32 15.1. TEST EQUIPMENT ........................................................................................................ 32 15.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 32 15.3. TEST PROCEDURE ...................................................................................................... 33 15.4. PERFORMANCE ........................................................................................................... 33 APPENDIX 1 ........................................................................................................................... 34 PHOTOGRAPHS OF TEST SETUP ....................................................................................... 34 APPENDIX 2 ........................................................................................................................... 35 PHOTOGRAPHS OF EUT ...................................................................................................... 35 Report No.: AGC10430912GZ06-1E1 Page 3 of 37 1. VERIFICATION OF CONFORMITY Equipment Under Test: Brand Name: 16 Port Dump Gigabit switch &16 Port Web-Smart Gigabit switch Rapidmax Model: RGS-1016WS, 524087, KN-S1016GM Difference: Only model name is different. Rapidmax Technology Corporation Applicant: 3F, 531 Chung-Cheng Rd. Hsin-Tien, Taipei231, Taiwan, R.O.C. File Number: Shenzhen Kingnet Electronic Co., Ltd 5/F, Block 4, Science & Technology Industrial Park of Private Enterprise Pingshan, Xili Town, Nanshan District, Shenzhen EMC Directive 2004/108/EC for CE Marking EN 55022: 2006 EN 61000-3-2: 2006 EN 61000-3-3: 2008 EN 55024: 1998 + A1: 2001 + A2: 2003 (IEC 61000-4-2: 2008; IEC 61000-4-3: 2008; IEC 61000-4-4: 2004; IEC 61000-4-5: 2005; IEC 61000-4-6: 2008; IEC 61000-4-11: 2004) AGC10430912GZ06-1E1 Date of test: Jan.06~ Jan.14, 2010 Deviation: None Condition of Test Sample: Normal Manufacturer: AG C Type of Test: Technical Standards: The above equipment was tested by Attestation Of Global Compliance Co., Ltd. for compliance with the requirements set forth in EMC Directive 2004/108/EC and the Technical Standards mentioned above. This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment and the level of the immunity endurance of the equipment are within the compliance requirements. The test results of this report relate only to the tested sample identified in this report. Checked By Jekey Zhang Jan.14, 2010 King Zhang Jan.14, 2010 Authorized By Report No.: AGC10430912GZ06-1E1 Page 4 of 37 2. SYSTEM DESCRIPTION EUT Test Procedure: 1. Connect EUT and peripheral devices (if need) 2. Power on the EUT, The EUT begins to work. AG C 3. Make sure the EUT works normally during the test. Report No.: AGC10430912GZ06-1E1 Page 5 of 37 3. PRODUCT INFORMATION Housing Type: Metal EUT Rating Voltage: AC 100-240V 50Hz/60Hz I/O Port Information ( Applicable Not Applicable) I/O Port of EUT Q’TY Cable Tested with AC INPUT PORT 1 1 1 DC OUTPUT PORT 1 1 1 AG C I/O Port Type Report No.: AGC10430912GZ06-1E1 Page 6 of 37 4. SUPPORT EQUIPMENT Device Type Manufacturer Model Name Serial No. Data Cable Power Cable -- -- -- -- -- -- **Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during emission test. AG C Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended use. Report No.: AGC10430912GZ06-1E1 Page 7 of 37 5. TEST FACILITY Location: F1, Bldg.A, Changyuan New Material Port, Keyuan Rd., Science & Industry Park, Nanshan District, 518057 Shenzhen, P.R. China Description: There is one 3m semi-anechoic an area test sites and two line conducted labs for final test. The Open Area Test Sites and the Line Conducted labs are constructed and calibrated to meet the FCC requirements in documents ANSI C63.4 and CISPR AG C 22/EN 55022 requirements. Site Filing: The site description is on file with the Federal Communications Commission, 7435 Oakland Mills Road, Columbia, MD 21046. Instrument Tolerance: All measuring equipment is in accord with ANSI C63.4 and CISPR 22 requirements that meet industry regulatory agency and accreditation agency requirement. Report No.: AGC10430912GZ06-1E1 Page 8 of 37 6. EN 55022 LINE CONDUCTED EMISSION TEST 6.1. TEST EQUIPMENT OF CONDUCTED EMISSION TEST Description Manufacturer Model Spectrum Analyzer Agilent E4440A LISN ETS Identifier N/A Cal. Date 06/29/2009 Cal. Due 06/28/2010 N/A 06/29/2009 06/28/2010 3816 6.2. LIMITS OF LINE CONDUCTED EMISSION TEST Maximum RF Line Voltage Q.P.( dBuV) Average( dBuV) Frequency 66-56 56-46 500kHz-5MHz 56 46 5MHz-30MHz 60 50 AG C 150kHz-500kHz **Note: 1. The lower limit shall apply at the transition frequency. 2.The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz 6.3. BLOCK DIAGRAM OF TEST SETUP S h ie ld e d R o o m F ilte r 0 .4 m E U T T o M e a s u r in g E q u ip m e n t 0 .8 m L IS N P o w e A : P o w e re d th ro u g h filte r Report No.: AGC10430912GZ06-1E1 Page 9 of 37 6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed on the ground plane as per EN55022 (see Test Facility for the dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. 2) Support equipment, if needed, was placed as per EN55022. 3) All I/O cables were positioned to simulate typical actual usage as per EN55022. 4) The EUT received AC100-240V/50Hz/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power source and was grounded to the ground plane. 5) All support equipments received power from a second LISN supplying power of AC 230V/50Hz, if any. 6) The EUT test program was started. Emissions were measured on each current carrying line of the EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver. 7) Analyzer / Receiver scanned from 150 kHz to 30 MHz for emissions in each of the test modes. 8) During the above scans, the emissions were maximized by cable manipulation. 9) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions. 10) Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. If EUT emission level was less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average detector. AG C 1) The test data of the worst case condition(s) was reported on the Summary Data page. Report No.: AGC10430912GZ06-1E1 Page 10 of 37 6.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST AG C Test Result of Line Conducted Emission Test-Neutral Line Report No.: AGC10430912GZ06-1E1 Page 11 of 37 AG C Test Result of Line Conducted Emission Test-Line Line Report No.: AGC10430912GZ06-1E1 Page 12 of 37 7. EN 55022 RADIATED EMISSION TEST 7.1. TEST EQUIPMENT OF RADIATED EMISSION TEST Description Manufacturer Model Spectrum Analyzer Agilent E4443A Identifier N/A Cal. Date 06/29/2009 Cal. Due 06/28/2010 Biconilog Antenna ETS 3142C N/A 06/29/2009 06/28/2010 Multi_device Controller ETS 2090 N/A 06/29/2009 06/28/2010 7.2. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES Frequency (MHz) Distance (m) Maximum Field Strength Limit 30-230 10 30.00 230-1000 10 37.00 AG C (dBuV/m Q.P.) **Note: The lower limit shall apply at the transition frequency. 7.3. BLOCK DIAGRAM OF TEST SETUP 1-4m EUT 0.8 m 10m Amplifier Spectrum Analyzer Report No.: AGC10430912GZ06-1E1 Page 13 of 37 7.4. PROCEDURE OF RADIATED EMISSION TEST AG C 1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of the ground plane used).When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. 2) Support equipment, if needed, was placed as per EN 55022. 3) All I/O cables were positioned to simulate typical actual usage as per EN 55022. 4) The EUT received AC100-240V/50Hz/60Hz power through the outlet socket under the turntable. All support equipments received AC230V/50Hz power from socket under the turntable, if any. 5) The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna connected to the Analyzer via a cable and at times a pre-amplifier would be used. 6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. 7) The test mode(s) were scanned during the test: 8) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and Q.P./Peak reading is presented. Report No.: AGC10430912GZ06-1E1 Page 14 of 37 AG C 7.5. TEST RESULT OF RADIATED EMISSION TEST AG C Report No.: AGC10430912GZ06-1E1 Page 15 of 37 Report No.: AGC10430912GZ06-1E1 Page 16 of 37 8. EN 61000-3-2 POWER HARMONICS TEST POWER HARMONICS MEASUREMENT Port : AC mains Basic Standard: Limits: EN 61000-3-2 :2006 CLASS A ; CLASS B; Tester: Sky Temperature: 25oC Humidity: 55% CLASS C; CLASS D AG C 8.1. BLOCK DIAGRAM OF TEST SETUP Harmonics & Flicker Analyzer + Power cord Power Source EUT 0.8m Support Units Report No.: AGC10430912GZ06-1E1 Page 17 of 37 8.2. LIMITS OF HARMONIC CURRENT Limits for Class A Equipment Harmonics Order n Max. permissible harmonic current (A) Odd harmonics 3 2.30 5 1.14 7 0.77 9 0.40 11 0.33 13 0.21 15≤n≤39 0.15×15/n Even harmonics 1.08 4 0.43 6 0.30 8≤n≤40 0.23×8/n AG C 2 NOTE: 1. According to section 5 of EN61000-3-2: 2006, the EUT is Class A equipment. 2. The above limits are for all applications having an active input power>75W. with an active input power up to and including 75W. 8.3. RESULT No limits apply for equipment Report No.: AGC10430912GZ06-1E1 Page 18 of 37 Harmonics Current (A) 0.025 0.018 0.017 0.015 0.012 0.010 0.008 0.006 0.006 0.005 0.004 0.003 0.003 0.002 0.002 0.002 0.002 0.001 0.000 0.000 Limit (A) --------------------- Harmonics Order 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Harmonics Current (A) 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Limit (A) --------------------- AG C Test Result Harmonics Order 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 NOTE: 1. The active input power of the EUT is 15 W. 2. No limits apply for equipment with an active input power up to and including 75W. Report No.: AGC10430912GZ06-1E1 Page 19 of 37 9. EN 61000-3-3 VOLTAGE FLUCTUATION / FLICKER TEST VOLTAGE FLUCTUATION/FLICKER MEASUREMENT Port : AC mains Basic Standard: EN 61000-3-3 :2008 Limits: §5 of EN 61000-3-3 Tester: Sky Temperature: 25oC Humidity: 55% Cal. Date Cal. Due 06/29/2009 06/28/2010 AG C 9.1. TEST EQUIPMENT OF VOLTAGE FLUCTUATION / FLICKER TEST Description Manufacturer Model Identifier California 500LIX-400-C Harmonic Emission Flicker N/A instruments TS 9.2. BLOCK DIAGRAM OF TEST SETUP Harmonics & Flicker Analyzer + Power cord Power Source EUT 0.8m 9.3. RESULT Support Units Report No.: AGC10430912GZ06-1E1 Page 20 of 37 Flicker Test Summary per EN/IEC61000-3-3 (Run time) EUT: 16 Port Dump Gigabit switch &16 Port Web-Smart Gigabit switch Tested by: Sky Test category: All parameters (European limits) Test Margin: 100 Test date: 2010-01-14 End time: 11:12:15 Start time: 11:02:15 Test duration (min): 10 Comment: On Customer: Rapidmax Technology Corporation Test Result: Pass Status: Test Completed Psti and limit line AG C European Limits 1.00 Pst 0.75 0.50 0.25 0.00 11:12:15 Time is too short for Plt plot Parameter values recorded during the test: Vrms at the end of test (Volt): 229.78 Highest dt (%): -0.13 Time(mS) > dt: 0.0 Highest dc (%): 0.00 Highest dmax (%): 0.08 Test limit (%): 3.30 Pass 500.0 Pass Test limit (%): 3.30 Pass Test limit (%): 4.00 Pass 1.000 Pass Test limit (mS): Highest Pst (10 min. period): 0.004 Test limit: Highest Plt (2 hr. period): 0.002 Test limit: 0.650 Pass Report No.: AGC10430912GZ06-1E1 Page 21 of 37 10. IEC 61000-4-2 ESD IMMUNITY TEST ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST Port : Basic Standard: Enclosure IEC 61000-4-2: 2008 Test Level: ± 8.0 kV (Air Discharge) ± 4.0 kV (Contact Discharge) ± 4.0 kV (Indirect Discharge) B Tester: Sky Temperature: 20oC Humidity: 50% AG C Standard require: 10.1. TEST EQUIPMENT OF ESD TEST Description Manufacturer ESD System HAEFELY Model PESD 1610 Identifier N/A Cal. Date 06/29/2009 Cal. Due 06/28/2010 10.2. BLOCK DIAGRAM OF TEST SETUP (The 470 k ohm resistors are installed per standard requirement) VCP EUT& Support Units Support units HCP >1m Wooden Table 0.8m Ground Reference Plane 10.3. TEST PROCEDURE The EUT was located 0.1 m minimum from all side of the HCP. The support units were located 1 m minimum away from the EUT. EUT worked with resistance load, and make sure EUT worked normally. Active the communication function if the EUT with such port(s). As per the requirement of EN 55024; applying direct contact discharge at a minimum four points of the EUT Report No.: AGC10430912GZ06-1E1 Page 22 of 37 at minimum 200 discharges (100 positive and 100 negative) if applicable, one of the test points shall be subjected to at least 50 indirect discharges(contact) to the centre of the front edge of the horizontal coupling plane. The remaining three test points shall each receive at least 50 direct contact discharges. If no direct contact test points available, then at least 200 indirect discharges shall be applied in the indirect mode. Tests shall be performed at a maximum repetition rate of one discharge per second. Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate points of EUT for air discharge, a minimum of 10 single air discharges shall be applied. The application of ESD to the contact of open connectors is not required. The following test condition was followed during the tests. Note: As per the A2 to IEC 61000-4-2, a bleed resistor cable is connected between the EUT and HCP during the test. The electrostatic discharges were applied as follows: AG C Amount of Discharges Mini 150 /Point Mini 50 /Point Mini 50 /Point Mini 50/Point Mini 50 /Point Mini 10 /Point Voltage Coupling Result (Pass/Fail) ±2kV; ±4kV ±2kV; ±4kV ±2kV; ±4kV ±2kV; ±4kV ±2kV; ±4kV ±2kV; ±4kV; ±8kV Contact Discharge Indirect Discharge HCP (Front) Indirect Discharge VCP (Left) Indirect Discharge VCP (Back) Indirect Discharge VCP (Right) Air Discharge Pass Pass Pass Pass Pass Pass 10.4. PERFORMANCE & RESULT Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Report No.: AGC10430912GZ06-1E1 Page 23 of 37 11. IEC 61000-4-3 TEST RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST Port : Enclosure Basic Standard: IEC 61000-4-3:2008 Test Level: 3V/m with 80% AM. 1kHz Modulation. Standard require: A Tester: Sky Temperature: 25oC Humidity: 55% Manufacturer IFA AR Model 2023B 150W1000 Identifier N/A N/A Cal. Date 06/29/2009 06/29/2009 Cal. Due 06/28/2010 06/28/2010 AR 25S1G4A N/A 06/29/2009 06/28/2010 AG C 11.1. TEST EQUIPMENT Description Signal Generator Power Amplifier Power Antenna 11.2. BLOCK DIAGRAM OF TEST SETUP 3 meter 7X4X3 Chamber EUT &Support Units 0.8m 1.5 meter Power Amp Signal Generator EUT Monitoring by using a camera PC Controller to control S.G. & PA as Control Room Report No.: AGC10430912GZ06-1E1 Page 24 of 37 11.3. TEST PROCEDURE The EUT was located at the edge of supporting table keep 3 meter away from transmitting antenna, it just the calibrated square area of field uniformity. The support units were located outside of the uniformity area, but the cable(s) connected with EUT were exposed to the calibrated field as per IEC 61000-4-3. EUT worked with resistance load, and make sure EUT worked normally. Setting the testing parameters of RS test software per IEC 61000-4-3. Performing the test at each side of with specified level (3V/m) at 1% steps and test frequency from 80MHz to 1000MHz Recording the test result in following table. IEC 61000-4-3 Final test conditions: Test level: 3V/m AG C Steps: 1 % of fundamental Dwell Time: 1 sec Range (MHz) Field Modulation Polarity Position Result (Pass/Fail) 80-1000 3V/m AM H Front Pass 80-1000 3V/m AM H Left Pass 80-1000 3V/m AM H Back Pass 80-1000 3V/m AM H Right Pass 80-1000 3V/m AM V Front Pass 80-1000 3V/m AM V Left Pass 80-1000 3V/m AM V Back Pass 80-1000 3V/m AM V Right Pass Report No.: AGC10430912GZ06-1E1 Page 25 of 37 11.4. PERFORMANCE & RESULT Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. AG C Criteria B: PASS FAIL Report No.: AGC10430912GZ06-1E1 Page 26 of 37 12. IEC 61000-4-4 TEST ELECTRICAL FAST TRANSIENTS/BURST IMMUNITY TEST Port : On Power Supply Lines Basic Standard: IEC 61000-4-4:2004 Test Level: +/- 1kV for Power Supply Lines Standard require: B Tester: Sky Temperature: 25oC Humidity: 55% AG C 12.1. TEST EQUIPMENT Description Compact Generator Capacitive Clamp CDN for Telecom Port Manufacturer EM-Test EM-Test EM-Test Model UCS500M/6B C Clamp HFK CNV504S1 Identifier N/A N/A N/A Cal. Date 06/29/2009 06/29/2009 06/29/2009 Cal. Due 06/28/2010 06/28/2010 06/28/2010 12.2. BLOCK DIAGRAM OF TEST SETUP EUT AC Line EFT/Burst/Surge Generator Controller Computer 80cm Support Units Non-Conductive Table Report No.: AGC10430912GZ06-1E1 Page 27 of 37 12.3. TEST PROCEDURE The EUT and support units were located on a wooden table 0.8m away from ground reference plane. A 1.0 meter long power cord was attached to EUT during the test. The length of communication cable between communication port and clamp was keeping within 1 meter. EUT worked with resistance load, and make sure EUT worked normally. Related peripherals work during the test. Recording the test result as shown in following table. Test conditions: Impulse Frequency: 5 kHz Tr/Th: 5/50ns Burst Duration: 15ms Burst Period: 300ms Voltage kV +1 -1 Inject Method Direct Direct Result (Pass/Fail) Pass Pass AG C Inject Line L+N L+N 12.4. PERFORMANCE & RESULT Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Report No.: AGC10430912GZ06-1E1 Page 28 of 37 13. IEC 61000-4-5 SURGE IMMUNITY TEST SURGE IMMUNITY TEST Port : On Power Supply Lines Basic Standard: IEC 61000-4-5:2005 +/- 1kV (Line to Line) Requirements : +/- 2kV (Line to Ground) B Tester: Sky Temperature: 25oC Humidity: 55% AG C Standard require: 13.1. TEST EQUIPMENT OF SURGE TEST Description Compact Generator Capacitive Clamp CDN for Telecom Port Manufacturer EM-Test EM-Test EM-Test Model UCS500M/6B C Clamp HFK CNV504S1 Identifier N/A N/A N/A Cal. Date 06/29/2009 06/29/2009 06/29/2009 13.2. BLOCK DIAGRAM OF TEST SETUP To AC Surge Immunity Test EUT Source & Support Units 80 cm Controller Computer Cal. Due 06/28/2010 06/28/2010 06/28/2010 Report No.: AGC10430912GZ06-1E1 Page 29 of 37 13.3. TEST PROCEDURE The EUT and support units were located on a wooden table 0.8 m away from ground floor. EUT worked with resistance load, and make sure EUT worked normally. Recording the test result as shown in following table. Test conditions: Voltage Waveform: Current Waveform: Polarity: Phase angle: Number of Test: Voltage (kV) 1 1 Polarity Positive Negative Coupling Method Capacitive Capacitive Result (Pass/Fail) Pass Pass AG C Coupling Line L1-L2 L1-L2 1.2/50 us 8/20 us Positive/Negative 0o, 90o, 270o 5 13.4. PERFORMANCE & RESULT Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Report No.: AGC10430912GZ06-1E1 Page 30 of 37 14. IEC 61000-4-6 TEST IEC 61000-4-6 IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELD Port : On Power Supply Lines Basic Standard: IEC 61000-4-6: 2008 Requirements : 3V with 80% AM. 1 kHz Modulation Standard require: A Tester: Sky Temperature: 25oC Humidity: 55% AG C 14.1. TEST EQUIPMENT Description Power Amplifier CDN Manufacturer AR EM-Test Model 75A250A N/A Identifier N/A N/A Cal. Date 06/29/2009 06/29/2009 Cal. Due 06/28/2010 06/28/2010 Direction Coupler EM-Test DC2600N N/A 06/29/2009 06/28/2010 EM-Clamp EM-Test EM101 N/A 06/29/2009 06/28/2010 Caliberation EM-Test CAM2/M3 N/A 06/29/2009 06/28/2010 Attenuator EM-Test ATT6/75 N/A 06/29/2009 06/28/2010 Power Sensor AR PH2000 N/A 06/29/2009 06/28/2010 Power Meter AR PM2002 N/A 06/29/2009 06/28/2010 Signal Generator IFA 2023B N/A 06/29/2009 06/28/2010 14.2. BLOCK DIAGRAM OF TEST SETUP PC Controller Power 0.1m< L <0.3m Amplifier 10 cm isolation supporter EUT and Support units CDN Ground Reference Plane Report No.: AGC10430912GZ06-1E1 Page 31 of 37 14.3. TEST PROCEDURE The EUT and support units were located at a ground reference plane with the interposition of a 0.1 m thickness insulating support and the CDN was located on GRP directly. EUT worked with resistance load, and make sure EUT worked normally. Related peripherals work during the test. Setting the testing parameters of CS test software per IEC 61000-4-6. Recording the test result in following table. Test conditions: 0.15MHz-80MHz Frequency Step: 1% of fundamental Dwell Time: 1 sec AG C Frequency Range: Range (MHz) Strength Modulation Result (Pass/Fail) 0.15-80 3V AM Pass 14.4. PERFORMANCE & RESULT Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Report No.: AGC10430912GZ06-1E1 Page 32 of 37 15. IEC 61000-4-11 TEST VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST Port : On Power Supply Lines Basic Standard: IEC 61000-4-11: 2004 Requirements : 0, 45, 90, 135, 180, 225, 270, 315 degrees Test Interval: Min. 10 sec. Tester: Sky Temperature: 25oC Humidity: 55% Reduction (%) >95 30 Duration ( periods ) 0.5 25 Performance Criteria B C Voltage Interruptions Test Level % UT <5 Reduction (%) >95 Duration ( periods ) 250 Performance Criteria C AG C Voltage Dips Test Level % UT <5 70 15.1. TEST EQUIPMENT Description Compact Generator Capacitive Clamp CDN for Telecom Port Manufacturer EM-Test EM-Test EM-Test Model UCS500M/6B C Clamp HFK CNV504S1 Identifier N/A N/A N/A Cal. Date 06/29/2009 06/29/2009 06/29/2009 15.2. BLOCK DIAGRAM OF TEST SETUP To AC Source Dips/Interruption and EUT Variations Simulator & Support Units 80 cm Controller Computer Cal. Due 06/28/2010 06/28/2010 06/28/2010 Report No.: AGC10430912GZ06-1E1 Page 33 of 37 15.3. TEST PROCEDURE The EUT and support units were located on a wooden table, 0.8 m away from ground floor. EUT worked with resistance load, and make sure EUT worked normally. Setting the parameter of tests and then perform the test software of test simulator. Conditions changes to occur at 0 degree crossover point of the voltage waveform. Recording the test result in test record form. Test conditions: The duration with a sequence of three dips/interruptions with interval of 10 s minimum (Between each test event) Voltage Dips: Reduction (%) >95 30 Duration ( periods) 0.5 25 Voltage Interruptions: Test Level Reduction % UT (%) <5 >95 Duration ( periods) 250 Observation Normal Normal Meet Performance Criteria B C AG C Test Level % UT <5 70 Observation Normal Meet Performance Criteria C 15.4. PERFORMANCE Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. In some cases the performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be restored by the operation of controls. PASS FAIL Report No.: AGC10430912GZ06-1E1 Page 34 of 37 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP AG C EN 55022 LINE CONDUCTED EMISSION TEST SETUP IEC 61000-4-2 ELECTROSTATIC DISCHARGE TEST SETUP Report No.: AGC10430912GZ06-1E1 Page 35 of 37 APPENDIX 2 PHOTOGRAPHS OF EUT AG C TOP VIEW OF EUT BOTTOM VIEW OF EUT Report No.: AGC10430912GZ06-1E1 Page 36 of 37 AG C LEFT VIEW OF EUT RIGHT VIEW OF EUT Report No.: AGC10430912GZ06-1E1 Page 37 of 37 AG C BACK VIEW OF EUT FRONT VIEW OF EUT -----END OF REPORT-----
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2010:01:18 08:51:01+08:00 Create Date : 2010:01:18 08:48:57+08:00 Metadata Date : 2010:01:18 08:51:01+08:00 Format : application/pdf Title : Microsoft Word - EMC Test Report_RGS-1016WS Creator : ANNA Document ID : uuid:35ad722b-1f77-4b12-8147-3932d190f3b4 Instance ID : uuid:70ef5593-f7df-46eb-980c-1c792cffc883 Page Count : 38 Author : ANNAEXIF Metadata provided by EXIF.tools