EMC Report_RGS 1016WS Report RGS

Emc Report Rgs-1016Ws EMC__Report_RGS-1016WS EMC__Report_RGS-1016WS CertsReports 524087 ProductFiles assets.mhint

2016-04-11

: Pdf Emc Report Rgs-1016Ws EMC__Report_RGS-1016WS CertsReports 524148 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 38

ELECTROMAGNETIC COMPLIANCE
TEST REPORT
For
16 Port Dump Gigabit switch&16 Port Web-Smart Gigabit switch
Model: RGS-1016WS, 524087, KN-S1016GM
Brand Name: Rapidmax
Report No.: AGC10430912GZ06-1E1
Date of Issue: Jan.14, 2010
Prepared For
Rapidmax Technology Corporation
3F, 531 Chung-Cheng Rd. Hsin-Tien, Taipei231, Taiwan, R.O.C.
TEL: 886-2-2219-6000
FAX: 886-2-2218-8833
Prepared By
Attestation of Global Compliance Co., Ltd.
2F., No.2 Building, Huafeng No.1 Technical Industrial Park, Sanwei,
Xixiang, Baoan District, Shenzhen
TEL: 86-755-2908 1966
FAX: 86-755-2600 8484
AGC
Report No.: AGC10430912GZ06-1E1
Page 1 of 37
TABLE OF CONTENTS
1. VERIFICATION OF CONFORMITY ...................................................................................... 3
2. SYSTEM DESCRIPTION ...................................................................................................... 4
3. PRODUCT INFORMATION .................................................................................................. 5
4. SUPPORT EQUIPMENT ....................................................................................................... 6
5. TEST FACILITY .................................................................................................................... 7
6. EN 55022 LINE CONDUCTED EMISSION TEST ................................................................. 8
6.1. TEST EQUIPMENT OF CONDUCTED EMISSION TEST ................................................. 8
6.2. LIMITS OF LINE CONDUCTED EMISSION TEST ............................................................ 8
6.3. BLOCK DIAGRAM OF TEST SETUP ................................................................................ 8
6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST ................................................. 9
6.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST .............................................. 10
7. EN 55022 RADIATED EMISSION TEST ............................................................................ 12
7.1. TEST EQUIPMENT OF RADIATED EMISSION TEST .................................................... 12
7.2. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES ..................................... 12
7.3. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 12
7.4. PROCEDURE OF RADIATED EMISSION TEST ............................................................. 13
7.5. TEST RESULT OF RADIATED EMISSION TEST ........................................................... 14
8. EN 61000-3-2 POWER HARMONICS TEST ...................................................................... 16
8.1. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 16
8.2. LIMITS OF HARMONIC CURRENT ................................................................................. 17
8.3. RESULT ........................................................................................................................... 17
9. EN 61000-3-3 VOLTAGE FLUCTUATION / FLICKER TEST ............................................. 19
9.1. TEST EQUIPMENT OF VOLTAGE FLUCTUATION / FLICKER TEST ............................ 19
9.2. BLOCK DIAGRAM OF TEST SETUP .............................................................................. 19
9.3. RESULT ........................................................................................................................... 19
10. IEC 61000-4-2 ESD IMMUNITY TEST .............................................................................. 21
10.1. TEST EQUIPMENT OF ESD TEST ............................................................................... 21
10.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 21
10.3. TEST PROCEDURE ...................................................................................................... 21
10.4. PERFORMANCE & RESULT ......................................................................................... 22
11. IEC 61000-4-3 TEST ......................................................................................................... 23
11.1. TEST EQUIPMENT ........................................................................................................ 23
11.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 23
11.3. TEST PROCEDURE ...................................................................................................... 24
AGC
Report No.: AGC10430912GZ06-1E1
Page 2 of 37
11.4. PERFORMANCE & RESULT ......................................................................................... 25
12. IEC 61000-4-4 TEST ......................................................................................................... 26
12.1. TEST EQUIPMENT ........................................................................................................ 26
12.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 26
12.3. TEST PROCEDURE ...................................................................................................... 27
12.4. PERFORMANCE & RESULT ......................................................................................... 27
13. IEC 61000-4-5 SURGE IMMUNITY TEST ........................................................................ 28
13.1. TEST EQUIPMENT OF SURGE TEST .......................................................................... 28
13.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 28
13.3. TEST PROCEDURE ...................................................................................................... 29
13.4. PERFORMANCE & RESULT ......................................................................................... 29
14. IEC 61000-4-6 TEST ......................................................................................................... 30
14.1. TEST EQUIPMENT ........................................................................................................ 30
14.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 30
14.3. TEST PROCEDURE ...................................................................................................... 31
14.4. PERFORMANCE & RESULT ......................................................................................... 31
15. IEC 61000-4-11 TEST ....................................................................................................... 32
15.1. TEST EQUIPMENT ........................................................................................................ 32
15.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................ 32
15.3. TEST PROCEDURE ...................................................................................................... 33
15.4. PERFORMANCE ........................................................................................................... 33
APPENDIX 1 ........................................................................................................................... 34
PHOTOGRAPHS OF TEST SETUP ....................................................................................... 34
APPENDIX 2 ........................................................................................................................... 35
PHOTOGRAPHS OF EUT ...................................................................................................... 35
AGC
Report No.: AGC10430912GZ06-1E1
Page 3 of 37
1. VERIFICATION OF CONFORMITY
Equipment Under Test: 16 Port Dump Gigabit switch &16 Port Web-Smart Gigabit switch
Brand Name: Rapidmax
Model: RGS-1016WS, 524087, KN-S1016GM
Difference: Only model name is different.
Applicant:
Rapidmax Technology Corporation
3F, 531 Chung-Cheng Rd. Hsin-Tien, Taipei231, Taiwan, R.O.C.
Manufacturer:
Shenzhen Kingnet Electronic Co., Ltd
5/F, Block 4, Science & Technology Industrial Park of Private Enterprise
Pingshan, Xili Town, Nanshan District, Shenzhen
Type of Test: EMC Directive 2004/108/EC for CE Marking
Technical Standards:
EN 55022: 2006
EN 61000-3-2: 2006
EN 61000-3-3: 2008
EN 55024: 1998 + A1: 2001 + A2: 2003
(IEC 61000-4-2: 2008; IEC 61000-4-3: 2008; IEC 61000-4-4: 2004;
IEC 61000-4-5: 2005; IEC 61000-4-6: 2008; IEC 61000-4-11: 2004)
File Number: AGC10430912GZ06-1E1
Date of test: Jan.06~ Jan.14, 2010
Deviation: None
Condition of Test Sample: Normal
The above equipment was tested by Attestation Of Global Compliance Co., Ltd. for compliance with the
requirements set forth in EMC Directive 2004/108/EC and the Technical Standards mentioned above. This
said equipment in the configuration described in this report shows the maximum emission levels emanating
from equipment and the level of the immunity endurance of the equipment are within the compliance
requirements.
The test results of this report relate only to the tested sample identified in this report.
Checked By
Jekey Zhang Jan.14, 2010
Authorized By
King Zhang Jan.14, 2010
AGC
Report No.: AGC10430912GZ06-1E1
Page 4 of 37
2. SYSTEM DESCRIPTION
EUT Test Procedure:
1. Connect EUT and peripheral devices (if need)
2. Power on the EUT, The EUT begins to work.
3. Make sure the EUT works normally during the test.
AGC
Report No.: AGC10430912GZ06-1E1
Page 5 of 37
3. PRODUCT INFORMATION
Housing Type: Metal
EUT Rating Voltage: AC 100-240V 50Hz/60Hz
I/O Port Information ( Applicable Not Applicable)
I/O Port of EUT
I/O Port Type Q’TY Cable Tested with
AC INPUT PORT 1 1 1
DC OUTPUT PORT 1 1 1
AGC
Report No.: AGC10430912GZ06-1E1
Page 6 of 37
4. SUPPORT EQUIPMENT
Device Type Manufacturer Model Name Serial No. Data Cable Power
Cable
-- -- -- -- -- --
**Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during
emission test.
Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended
use.
AGC
Report No.: AGC10430912GZ06-1E1
Page 7 of 37
5. TEST FACILITY
Location: F1, Bldg.A, Changyuan New Material Port, Keyuan Rd., Science & Industry Park,
Nanshan District, 518057 Shenzhen, P.R. China
Description: There is one 3m semi-anechoic an area test sites and two line conducted labs for final
test. The Open Area Test Sites and the Line Conducted labs are constructed and
calibrated to meet the FCC requirements in documents ANSI C63.4 and CISPR
22/EN 55022 requirements.
Site Filing: The site description is on file with the Federal Communications Commission, 7435
Oakland Mills Road, Columbia, MD 21046.
Instrument Tolerance: All measuring equipment is in accord with ANSI C63.4 and CISPR 22 requirements
that meet industry regulatory agency and accreditation agency requirement.
AGC
Report No.: AGC10430912GZ06-1E1
Page 8 of 37
6. EN 55022 LINE CONDUCTED EMISSION TEST
6.1. TEST EQUIPMENT OF CONDUCTED EMISSION TEST
Description Manufacturer Model Identifier Cal. Date Cal. Due
Spectrum Analyzer Agilent E4440A N/A 06/29/2009 06/28/2010
LISN ETS 3816 N/A 06/29/2009 06/28/2010
6.2. LIMITS OF LINE CONDUCTED EMISSION TEST
Frequency Maximum RF Line Voltage
Q.P.( dBuV) Average( dBuV)
150kHz-500kHz 66-56 56-46
500kHz-5MHz 56 46
5MHz-30MHz 60 50
**Note: 1. The lower limit shall apply at the transition frequency.
2.The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz
6.3. BLOCK DIAGRAM OF TEST SETUP
F ilte r
LISN
EUT
To M easuring Equipm ent
Pow e
0.4m
0.8m
S h ie ld e d R o o m
A: Pow ered through filter
AGC
Report No.: AGC10430912GZ06-1E1
Page 9 of 37
6.4. PROCEDURE OF LINE CONDUCTED EMISSION TEST
1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
placed on the ground plane as per EN55022 (see Test Facility for the dimensions of the ground plane
used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
mm non-conductive covering to insulate the EUT from the ground plane.
2) Support equipment, if needed, was placed as per EN55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN55022.
4) The EUT received AC100-240V/50Hz/60Hz power through a Line Impedance Stabilization Network (LISN)
which supplied power source and was grounded to the ground plane.
5) All support equipments received power from a second LISN supplying power of AC 230V/50Hz, if any.
6) The EUT test program was started. Emissions were measured on each current carrying line of the EUT
using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
7) Analyzer / Receiver scanned from 150 kHz to 30 MHz for emissions in each of the test modes.
8) During the above scans, the emissions were maximized by cable manipulation.
9) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
10) Emission frequency and amplitude were recorded into a computer in which correction factors were used to
calculate the emission level and compare reading to the applicable limit. If EUT emission level was
less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
detector.
The test data of the worst case condition(s) was reported on the Summary Data page.
AGC
Report No.: AGC10430912GZ06-1E1
Page 10 of 37
6.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST
Test Result of Line Conducted Emission Test-Neutral Line
AGC
Report No.: AGC10430912GZ06-1E1
Page 11 of 37
Test Result of Line Conducted Emission Test-Line Line

AGC
Report No.: AGC10430912GZ06-1E1
Page 12 of 37
7. EN 55022 RADIATED EMISSION TEST
7.1. TEST EQUIPMENT OF RADIATED EMISSION TEST
Description Manufacturer Model Identifier Cal. Date Cal. Due
Spectrum Analyzer Agilent E4443A N/A 06/29/2009 06/28/2010
Biconilog Antenna ETS 3142C N/A 06/29/2009 06/28/2010
Multi_device Controller ETS 2090 N/A 06/29/2009 06/28/2010
7.2. LIMITS OF RADIATED DISTURBANCES AT 10M DISTANCES
Frequency
(MHz)
Distance
(m)
Maximum Field Strength Limit
(dBuV/m Q.P.)
30-230 10 30.00
230-1000 10 37.00
**Note: The lower limit shall apply at the transition frequency.
7.3. BLOCK DIAGRAM OF TEST SETUP
Spectrum
Analyzer
10m
1-4m
0.8 m
Amplifier
EUT
AGC
Report No.: AGC10430912GZ06-1E1
Page 13 of 37
7.4. PROCEDURE OF RADIATED EMISSION TEST
1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which
is placed on the ground plane as per EN 55022 (see Test Facility for the dimensions of the ground plane
used).When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm
non-conductive covering to insulate the EUT from the ground plane.
2) Support equipment, if needed, was placed as per EN 55022.
3) All I/O cables were positioned to simulate typical actual usage as per EN 55022.
4) The EUT received AC100-240V/50Hz/60Hz power through the outlet socket under the turntable. All support
equipments received AC230V/50Hz power from socket under the turntable, if any.
5) The antenna was placed at 10 meter away from the EUT as stated in EN 55022. The antenna connected to
the Analyzer via a cable and at times a pre-amplifier would be used.
6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was started.
Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to
4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the
emission reading level.
7) The test mode(s) were scanned during the test:
8) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization
and turntable position were recorded into a computer in which correction factors were used to calculate the
emission level and compare reading to the applicable limit and Q.P./Peak reading is presented.
AGC
Report No.: AGC10430912GZ06-1E1
Page 14 of 37
7.5. TEST RESULT OF RADIATED EMISSION TEST
AGC
Report No.: AGC10430912GZ06-1E1
Page 15 of 37
AGC
Report No.: AGC10430912GZ06-1E1
Page 16 of 37
8. EN 61000-3-2 POWER HARMONICS TEST
POWER HARMONICS MEASUREMENT
Port : AC mains
Basic Standard: EN 61000-3-2 :2006
Limits: CLASS A ; CLASS B; CLASS C; CLASS D
Tester: Sky
Temperature: 25oC
Humidity: 55%
8.1. BLOCK DIAGRAM OF TEST SETUP
Harmonics & Flicker
Analyzer
+
Power Source
EUT
Support Units
Power cord
0.8m
AGC
Report No.: AGC10430912GZ06-1E1
Page 17 of 37
8.2. LIMITS OF HARMONIC CURRENT
Limits for Class A Equipment
Harmonics Order n Max. permissible harmonic current (A)
Odd harmonics
3 2.30
5 1.14
7 0.77
9 0.40
11 0.33
13 0.21
15n39 0.15×15/n
Even harmonics
2 1.08
4 0.43
6 0.30
8n40 0.23×8/n
NOTE:
1. According to section 5 of EN61000-3-2: 2006, the EUT is Class A equipment.
2. The above limits are for all applications having an active input power>75W. No limits apply for equipment
with an active input power up to and including 75W.
8.3. RESULT
AGC
Report No.: AGC10430912GZ06-1E1
Page 18 of 37
Test Result
Harmonics
Order
Harmonics Current
(A) Limit (A) Harmonics
Order
Harmonics Current
(A) Limit (A)
1 0.025 -- 2 0.001 --
3 0.018 -- 4 0.000 --
5 0.017 -- 6 0.000 --
7 0.015 -- 8 0.000 --
9 0.012 -- 10 0.000 --
11 0.010 -- 12 0.000 --
13 0.008 -- 14 0.000 --
15 0.006 -- 16 0.000 --
17 0.006 -- 18 0.000 --
19 0.005 -- 20 0.000 --
21 0.004 -- 22 0.000 --
23 0.003 -- 24 0.000 --
25 0.003 -- 26 0.000 --
27 0.002 -- 28 0.000 --
29 0.002 -- 30 0.000 --
31 0.002 -- 32 0.000 --
33 0.002 -- 34 0.000 --
35 0.001 -- 36 0.000 --
37 0.000 -- 38 0.000 --
39 0.000 -- 40 0.000 --
NOTE:
1. The active input power of the EUT is 15 W.
2. No limits apply for equipment with an active input power up to and including 75W.
AGC
Report No.: AGC10430912GZ06-1E1
Page 19 of 37
9. EN 61000-3-3 VOLTAGE FLUCTUATION / FLICKER TEST
VOLTAGE FLUCTUATION/FLICKER MEASUREMENT
Port : AC mains
Basic Standard: EN 61000-3-3 :2008
Limits: §5 of EN 61000-3-3
Test e r : Sky
Temperature: 25oC
Humidity: 55%
9.1. TEST EQUIPMENT OF VOLTAGE FLUCTUATION / FLICKER TEST
Description Manufacturer Model Identifier Cal. Date Cal. Due
Harmonic Emission Flicker California
instruments
500LIX-400-C
TS N/A 06/29/2009 06/28/2010
9.2. BLOCK DIAGRAM OF TEST SETUP
9.3. RESULT
Harmonics & Flicker
Analyzer
+
Power Source
EUT
Support Units
Power cord
0.8m
AGC
Report No.: AGC10430912GZ06-1E1
Page 20 of 37
Flicker Test Summary per EN/IEC61000-3-3 (Run time)
EUT: 16 Port Dump Gigabit switch &16 Port Web-Smart Gigabit switch Tested by: Sky
Test category: All parameters (European limits) Test Margin: 100
Test date: 2010-01-14 Start time: 11:02:15 End time: 11:12:15
Test duration (min): 10
Comment: On
Customer: Rapidmax Technology Corporation
Test Result: Pass Status: Test Completed
Psti and limit line European Limits
0.00
0.25
0.50
0.75
1.00
Pst
11:12:15
Time is too short for Plt plot
Parameter values recorded during the test:
Vrms at the end of test (Volt): 229.78
Highest dt (%): -0.13 Test limit (%): 3.30 Pass
Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass
Highest dc (%): 0.00 Test limit (%): 3.30 Pass
Highest dmax (%): 0.08 Test limit (%): 4.00 Pass
Highest Pst (10 min. period): 0.004 Test limit: 1.000 Pass
Highest Plt (2 hr. period): 0.002 Test limit: 0.650 Pass
AGC
Report No.: AGC10430912GZ06-1E1
Page 21 of 37
10. IEC 61000-4-2 ESD IMMUNITY TEST
ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST
Port : Enclosure
Basic Standard: IEC 61000-4-2: 2008
Test Level: ± 8.0 kV (Air Discharge)
± 4.0 kV (Contact Discharge)
± 4.0 kV (Indirect Discharge)
Standard require: B
Tester: Sky
Temperature: 20oC
Humidity: 50%
10.1. TEST EQUIPMENT OF ESD TEST
Description Manufacturer Model Identifier Cal. Date Cal. Due
ESD System HAEFELY PESD 1610 N/A 06/29/2009 06/28/2010
10.2. BLOCK DIAGRAM OF TEST SETUP
(The 470 k ohm resistors are installed per standard requirement)
10.3. TEST PROCEDURE
The EUT was located 0.1 m minimum from all side of the HCP.
The support units were located 1 m minimum away from the EUT.
EUT worked with resistance load, and make sure EUT worked normally.
Active the communication function if the EUT with such port(s).
As per the requirement of EN 55024; applying direct contact discharge at a minimum four points of the EUT
Ground Reference Plane
Wooden Table
Support units
EUT&
Support
Units
VCP
HCP
>1m
0.8m
AGC
Report No.: AGC10430912GZ06-1E1
Page 22 of 37
at minimum 200 discharges (100 positive and 100 negative) if applicable, one of the test points shall be
subjected to at least 50 indirect discharges(contact) to the centre of the front edge of the horizontal coupling
plane. The remaining three test points shall each receive at least 50 direct contact discharges. If no direct
contact test points available, then at least 200 indirect discharges shall be applied in the indirect mode. Tests
shall be performed at a maximum repetition rate of one discharge per second.
Other parts of EUT where it is not possible to perform contact discharge then selecting appropriate points of
EUT for air discharge, a minimum of 10 single air discharges shall be applied.
The application of ESD to the contact of open connectors is not required.
The following test condition was followed during the tests.
Note: As per the A2 to IEC 61000-4-2, a bleed resistor cable is connected between the EUT and HCP during the test.
The electrostatic discharges were applied as follows:
Amount of
Discharges Voltage Coupling Result (Pass/Fail)
Mini 150 /Point ±2kV; ±4kV Contact Discharge Pass
Mini 50 /Point ±2kV; ±4kV Indirect Discharge HCP (Front) Pass
Mini 50 /Point ±2kV; ±4kV Indirect Discharge VCP (Left) Pass
Mini 50/Point ±2kV; ±4kV Indirect Discharge VCP (Back) Pass
Mini 50 /Point ±2kV; ±4kV Indirect Discharge VCP (Right) Pass
Mini 10 /Point ±2kV; ±4kV; ±8kV Air Discharge Pass
10.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.
PASS FAIL
AGC
Report No.: AGC10430912GZ06-1E1
Page 23 of 37
11. IEC 61000-4-3 TEST
RADIATED ELECTROMAGNETIC FIELD IMMUNITY TEST
Port : Enclosure
Basic Standard: IEC 61000-4-3:2008
Test Level: 3V/m with 80% AM. 1kHz Modulation.
Standard require: A
Tester: Sky
Temperature: 25oC
Humidity: 55%
11.1. TEST EQUIPMENT
Description Manufacturer Model Identifier Cal. Date Cal. Due
Signal Generator IFA 2023B N/A 06/29/2009 06/28/2010
Power Amplifier AR 150W1000 N/A 06/29/2009 06/28/2010
Power Antenna AR 25S1G4A N/A 06/29/2009 06/28/2010
11.2. BLOCK DIAGRAM OF TEST SETUP
3 meter
1.5 meter
Power Amp Signal
Generato
r
EUT Monitoring by using
a camera
0.8m
Control Room
7X4X3 Chamber
EUT &Support Units
PC Controller to control
S.G. & PA as
AGC
Report No.: AGC10430912GZ06-1E1
Page 24 of 37
11.3. TEST PROCEDURE
The EUT was located at the edge of supporting table keep 3 meter away from transmitting antenna, it just
the calibrated square area of field uniformity. The support units were located outside of the uniformity area, but
the cable(s) connected with EUT were exposed to the calibrated field as per IEC 61000-4-3.
EUT worked with resistance load, and make sure EUT worked normally.
Setting the testing parameters of RS test software per IEC 61000-4-3.
Performing the test at each side of with specified level (3V/m) at 1% steps and test frequency from 80MHz
to 1000MHz
Recording the test result in following table.
IEC 61000-4-3 Final test conditions:
Test level: 3V/m
Steps: 1 % of fundamental
Dwell Time: 1 sec
Range (MHz) Field Modulation Polarity Position Result (Pass/Fail)
80-1000 3V/m AM H Front Pass
80-1000 3V/m AM H Left Pass
80-1000 3V/m AM H Back Pass
80-1000 3V/m AM H Right Pass
80-1000 3V/m AM V Front Pass
80-1000 3V/m AM V Left Pass
80-1000 3V/m AM V Back Pass
80-1000 3V/m AM V Right Pass
AGC
Report No.: AGC10430912GZ06-1E1
Page 25 of 37
11.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.
PASS FAIL
AGC
Report No.: AGC10430912GZ06-1E1
Page 26 of 37
12. IEC 61000-4-4 TEST
ELECTRICAL FAST TRANSIENTS/BURST IMMUNITY TEST
Port : On Power Supply Lines
Basic Standard: IEC 61000-4-4:2004
Test Level: +/- 1kV for Power Supply Lines
Standard require: B
Tester: Sky
Temperature: 25oC
Humidity: 55%
12.1. TEST EQUIPMENT
12.2. BLOCK DIAGRAM OF TEST SETUP
Description Manufacturer Model Identifier Cal. Date Cal. Due
Compact Generator EM-Test UCS500M/6B N/A 06/29/2009 06/28/2010
Capacitive Clamp EM-Test C Clamp HFK N/A 06/29/2009 06/28/2010
CDN for Telecom Port EM-Test CNV504S1 N/A 06/29/2009 06/28/2010
Controller Computer
EFT/Burst/Surge
Generator
EUT
Support Units
AC
80cm
Non-Conductive Table
Line
AGC
Report No.: AGC10430912GZ06-1E1
Page 27 of 37
12.3. TEST PROCEDURE
The EUT and support units were located on a wooden table 0.8m away from ground reference plane.
A 1.0 meter long power cord was attached to EUT during the test.
The length of communication cable between communication port and clamp was keeping within 1 meter.
EUT worked with resistance load, and make sure EUT worked normally.
Related peripherals work during the test.
Recording the test result as shown in following table.
Test conditions:
Impulse Frequency: 5 kHz
Tr/Th: 5/50ns
Burst Duration: 15ms
Burst Period: 300ms
Inject Line Voltage kV Inject Method Result (Pass/Fail)
L+N + 1 Direct Pass
L+N - 1 Direct Pass
12.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.
PASS FAIL
AGC
Report No.: AGC10430912GZ06-1E1
Page 28 of 37
13. IEC 61000-4-5 SURGE IMMUNITY TEST
SURGE IMMUNITY TEST
Port : On Power Supply Lines
Basic Standard: IEC 61000-4-5:2005
Requirements :
+/- 1kV (Line to Line)
+/- 2kV (Line to Ground)
Standard require: B
Tester: Sky
Temperature: 25oC
Humidity: 55%
13.1. TEST EQUIPMENT OF SURGE TEST
13.2. BLOCK DIAGRAM OF TEST SETUP
Description Manufacturer Model Identifier Cal. Date Cal. Due
Compact Generator EM-Test UCS500M/6B N/A 06/29/2009 06/28/2010
Capacitive Clamp EM-Test C Clamp HFK N/A 06/29/2009 06/28/2010
CDN for Telecom Port EM-Test CNV504S1 N/A 06/29/2009 06/28/2010
Surge Immunity Test
Controller Computer
EUT
&
Support Units
80 cm
To A C
Source
AGC
Report No.: AGC10430912GZ06-1E1
Page 29 of 37
13.3. TEST PROCEDURE
The EUT and support units were located on a wooden table 0.8 m away from ground floor.
EUT worked with resistance load, and make sure EUT worked normally.
Recording the test result as shown in following table.
Test conditions:
Voltage Waveform: 1.2/50 us
Current Waveform: 8/20 us
Polarity: Positive/Negative
Phase angle: 0o, 90o, 270o
Number of Test: 5
13.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by the
manufacturer, when the apparatus is used as intended. In some cases the performance level
may be replaced by a permissible loss of performance. During the test, degradation of
performance is however allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.
Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail)
L1-L2 1 Positive Capacitive Pass
L1-L2 1 Negative Capacitive Pass
PASS FAIL
AGC
Report No.: AGC10430912GZ06-1E1
Page 30 of 37
14. IEC 61000-4-6 TEST
IEC 61000-4-6 IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY
FIELD
Port : On Power Supply Lines
Basic Standard: IEC 61000-4-6: 2008
Requirements : 3V with 80% AM. 1 kHz Modulation
Standard require: A
Tester: Sky
Temperature: 25oC
Humidity: 55%
14.1. TEST EQUIPMENT
Description Manufacturer Model Identifier Cal. Date Cal. Due
Power Amplifier AR 75A250A N/A 06/29/2009 06/28/2010
CDN EM-Test N/A N/A 06/29/2009 06/28/2010
Direction Coupler EM-Test DC2600N N/A 06/29/2009 06/28/2010
EM-Clamp EM-Test EM101 N/A 06/29/2009 06/28/2010
Caliberation EM-Test CAM2/M3 N/A 06/29/2009 06/28/2010
Attenuator EM-Test ATT6/75 N/A 06/29/2009 06/28/2010
Power Sensor AR PH2000 N/A 06/29/2009 06/28/2010
Power Meter AR PM2002 N/A 06/29/2009 06/28/2010
Signal Generator IFA 2023B N/A 06/29/2009 06/28/2010
14.2. BLOCK DIAGRAM OF TEST SETUP
CDN
EUT and
Support units
Power
Amplifier
PC
Controller
Ground Reference Plane
10 cm isolation supporter
0.1m< L <0.3m
AGC
Report No.: AGC10430912GZ06-1E1
Page 31 of 37
14.3. TEST PROCEDURE
The EUT and support units were located at a ground reference plane with the interposition of a 0.1 m
thickness insulating support and the CDN was located on GRP directly.
EUT worked with resistance load, and make sure EUT worked normally.
Related peripherals work during the test.
Setting the testing parameters of CS test software per IEC 61000-4-6.
Recording the test result in following table.
Test conditions:
Frequency Range: 0.15MHz-80MHz
Frequency Step: 1% of fundamental
Dwell Time: 1 sec
14.4. PERFORMANCE & RESULT
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.
PASS FAIL
Range (MHz) Strength Modulation Result (Pass/Fail)
0.15-80 3V AM Pass
AGC
Report No.: AGC10430912GZ06-1E1
Page 32 of 37
15. IEC 61000-4-11 TEST
VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST
Port : On Power Supply Lines
Basic Standard: IEC 61000-4-11: 2004
Requirements : 0, 45, 90, 135, 180, 225, 270, 315 degrees
Test Interval: Min. 10 sec.
Tester: Sky
Temperature: 25oC
Humidity: 55%
Voltage Dips
Test Level
% UT
Reduction
(%)
Duration
( periods )
Performance
Criteria
<5 >95 0.5 B
70 30 25 C
Voltage Interruptions
Test Level
% UT
Reduction
(%)
Duration
( periods )
Performance
Criteria
<5 >95 250 C
15.1. TEST EQUIPMENT
15.2. BLOCK DIAGRAM OF TEST SETUP
Description Manufacturer Model Identifier Cal. Date Cal. Due
Compact Generator EM-Test UCS500M/6B N/A 06/29/2009 06/28/2010
Capacitive Clamp EM-Test C Clamp HFK N/A 06/29/2009 06/28/2010
CDN for Telecom Port EM-Test CNV504S1 N/A 06/29/2009 06/28/2010
Dips/Interruption and
Variations Simulator
Controller Computer
EUT
&
Support Units
80 cm
To A C
Source
AGC
Report No.: AGC10430912GZ06-1E1
Page 33 of 37
15.3. TEST PROCEDURE
The EUT and support units were located on a wooden table, 0.8 m away from ground floor.
EUT worked with resistance load, and make sure EUT worked normally.
Setting the parameter of tests and then perform the test software of test simulator.
Conditions changes to occur at 0 degree crossover point of the voltage waveform.
Recording the test result in test record form.
Test conditions:
The duration with a sequence of three dips/interruptions with interval of 10 s minimum
(Between each test event)
Voltage Dips:
Test Level
% UT
Reduction
(%)
Duration
( periods) Observation Meet Performance
Criteria
<5 >95 0.5 Normal B
70 30 25 Normal C
Voltage Interruptions:
Test Level
% UT
Reduction
(%)
Duration
( periods) Observation Meet Performance
Criteria
<5 >95 250 Normal C
15.4. PERFORMANCE
Criteria A: The apparatus continues to operate as intended. No degradation of performance or loss of
function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. In some cases the performance level may be replaced by a
permissible loss of performance.
Criteria B: The apparatus continues to operate as intended after the test. No degradation of performance
or loss of function is allowed below a performance level specified by the manufacturer, when
the apparatus is used as intended. In some cases the performance level may be replaced by
a permissible loss of performance. During the test, degradation of performance is however
allowed.
Criteria C: Temporary loss of function is allowed, provided the functions self recoverable or can be
restored by the operation of controls.
PASS FAIL
AGC
Report No.: AGC10430912GZ06-1E1
Page 34 of 37
APPENDIX 1
PHOTOGRAPHS OF TEST SETUP
EN 55022 LINE CONDUCTED EMISSION TEST SETUP
IEC 61000-4-2 ELECTROSTATIC DISCHARGE TEST SETUP
AGC
Report No.: AGC10430912GZ06-1E1
Page 35 of 37
APPENDIX 2
PHOTOGRAPHS OF EUT
TOP VIEW OF EUT
BOTTOM VIEW OF EUT
AGC
Report No.: AGC10430912GZ06-1E1
Page 36 of 37
LEFT VIEW OF EUT
RIGHT VIEW OF EUT
AGC
Report No.: AGC10430912GZ06-1E1
Page 37 of 37
BACK VIEW OF EUT
FRONT VIEW OF EUT
-----END OF REPORT-----