EN 300440

2016-04-12

: Pdf En 300440 EN_300440 CertsReports 525824 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 31

DownloadEN 300440
Open PDF In BrowserView PDF
Shenzhen SEM.Test Technology Co., Ltd.

Radio
Measurement and Test Report
For
Winstars Technology Limited

t

Block 4, TaiSong Industrial Park, DaLang Street, LongHua Town, Bao’an

es

district, Shenzhen, China

EN 300 440-1 V1.6.1 (2010-08)
EN 300 440-2 V1.4.1 (2010-08)

Test Standards:
Product Description:

High Power Wi-fi AP/Router
WS-WN570HA1

SE
M.
T

Tested Model:
Report No.:

STR15098069E-2

Tested Date:

2015-09-08 to 2015-09-22

Issued Date:

2015-09-22

Tested By:

Jack Kang / Engineer

Reviewed By:

Silin Chen / Engineer

Approved & Authorized By:

Jandy So / PSQ Manager

Prepared By:

Shenzhen SEM.Test Technology Co., Ltd.
1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
Bao'an District, Shenzhen, P.R.C.(518101)

Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn

Note: This test report is limited to the above client company and the product model only. It
may not be duplicated without prior permitted by Shenzhen SEM.Test Technology Co., Ltd.

REPORT NO.: STR15098069E-2

PAGE 1 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

TABLE OF CONTENTS
1 GENERAL INFORMATION ..................................................................................................................................... 3 
1.1 Product Description for Equipment Under Test (EUT) .................................................................................... 3 
1.2 Test Standards ................................................................................................................................................... 4 
1.3 Test Methodology ............................................................................................................................................. 4 
1.4 Test Facility ....................................................................................................................................................... 4 
1.5 EUT Setup and Test Mode ................................................................................................................................ 5 
1.6 Measurement Uncertainty ................................................................................................................................. 5 
1.7 Test Equipment List and Details ....................................................................................................................... 6 
2. SUMMARY OF TEST RESULTS ............................................................................................................................. 7 

t

3. EQUIVALENT ISOTROPICALLY RADIATED POWER ..................................................................................................... 8 
3.1 Standard Applicable .......................................................................................................................................... 8 
3.2 Test Procedure ................................................................................................................................................... 8 
3.3 Summary of Test Results .................................................................................................................................. 9 

es

4. PERMITTED RANGE OF OPERATING FREQUENCIES .................................................................................................. 10 
4.1 Applicable Standard ........................................................................................................................................ 10 
4.2 Test Procedure ................................................................................................................................................. 10 
4.3 Test Results/Plots ............................................................................................................................................ 11 
5. SPURIOUS EMISSIONS ................................................................................................................................................. 13 
5.1 Limit of Spurious Emissions........................................................................................................................... 13 
5.2 Test Procedure ................................................................................................................................................. 13 
5.3 Environmental Conditions .............................................................................................................................. 13 
5.4 Summary of Test Results/Plots ....................................................................................................................... 13 

SE
M.
T

6. DUTY CYCLE .............................................................................................................................................................. 21 
6.1 Applicable Standard ........................................................................................................................................ 21 
6.2 Test Procedure ................................................................................................................................................. 21 
6.3 Environmental Conditions .............................................................................................................................. 21 
6.4 Summary of Test Results/Plots ....................................................................................................................... 21 
7. RECEIVER SPURIOUS EMISSIONS ............................................................................................................................... 22 
7.1 Limit of Spurious Emissions........................................................................................................................... 22 
7.2 Test Procedure ................................................................................................................................................. 22 
7.3 Environmental Conditions .............................................................................................................................. 22 
7.4 Summary of Test Results/Plots ....................................................................................................................... 22 
EXHIBIT 1 - PRODUCT LABELING ........................................................................................................................ 25 
Proposed CE Label Format ................................................................................................................................... 25 
Proposed Label Location on EUT......................................................................................................................... 25 
EXHIBIT 2 - EUT PHOTOGRAPHS.......................................................................................................................... 26 
EXHIBIT 3 - TEST SETUP PHOTOGRAPHS .......................................................................................................... 30 

REPORT NO.: STR15098069E-2

PAGE 2 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

1 GENERAL INFORMATION
1.1 Product Description for Equipment Under Test (EUT)

General Description of EUT
Product Name:
Trade Name:
Model No.:
Adding Model(s):
Rated Voltage:

High Power Wi-fi AP/Router
N/A
WS-WN570HA1
525824
DC 24V from adapter
Model: TDX-2400500
Input: AC 100-240V 50/60Hz, Output: DC 24V 0.5A

SE
M.
T

Power Adaptor Model:

t

Manufacturer:
Address of manufacturer:

Winstars Technology Limited
Block 4, TaiSong Industrial Park, DaLang Street, LongHua
Town, Bao’an district, Shenzhen, China
Winstars Technology Limited
Block 4, TaiSong Industrial Park, DaLang Street, LongHua
Town, Bao’an district, Shenzhen, China

es

Client Information
Applicant:
Address of applicant:

Note: The test data is gathered from a production sample, provided by the manufacturer.

Technical Characteristics of EUT
Wi-Fi(5.8G)
Support Standards:
Frequency Range:
RF Output Power:
Type of Modulation:
Quantity of Channels
Channel Separation:
Type of Antenna:
Antenna Gain:

REPORT NO.: STR15098069E-2

802.11ac
5775-5825MHz for 802.11a
13.52dBm (EIRP)
BPSK/QPSK/16QAM/64QAM/256QAM
6 for 802.11ac
10MHz
External Antenna
7.0dBi

PAGE 3 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

1.2 Test Standards
The following report is prepared on behalf of the Winstars Technology Limited in accordance with ETSI EN 300
440-2, Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment
to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE
Directive.

t

The objective of the manufacturer is to determine compliance with ETSI EN 300 440-2, Electromagnetic
compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz
to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive.

1.3 Test Methodology

es

Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product maybe
which result in lowering the immunity should be checked to ensure compliance has been maintained

SE
M.
T

All measurements contained in this report were conducted with ETSI EN 300 440-1, Electromagnetic
compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in
the 1 GHz to 40 GHz frequency range; Part 1: Technical characteristics and test methods.
The equipment under test (EUT) was configured to measure its highest possible emission level. For more detail
refer to the Operating Instructions.

1.4 Test Facility

FCC – Registration No.: 934118
Shenzhen SEM.Test Technology Co., Ltd. EMC Laboratory has been registered and fully described in a report
filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in
our files and the Registration is 934118.
Industry Canada (IC) Registration No.: 11464A
The 3m Semi-anechoic chamber of Shenzhen SEM.Test Technology Co., Ltd. has been registered by Certification
and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 11464A.
CNAS Registration No.: L4062
Shenzhen SEM.Test Technology Co., Ltd. is a testing organization accredited by China National Accreditation
Service for Conformity Assessment (CNAS) according to ISO/IEC 17025. The accreditation certificate number is
L4062. All measurement facilities used to collect the measurement data are located at 1/F, Building A, Hongwei
Industrial Park, Liuxian 2nd Road, Bao’an District, Shenzhen, P.R.C (518101).

REPORT NO.: STR15098069E-2

PAGE 4 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

1.5 EUT Setup and Test Mode
The equipment under test (EUT) was configured to measure its highest possible emission/immunity level. The test
modes were adapted according to the operation manual for use, the EUT was operated in the engineering mode to
fix the Tx frequency that was for the purpose of the measurements, more detailed description as follows:
Test Mode List
Description

Remark

TM1

Low Channel

5775 MHz

TM2

Middle Channel

5805 MHz

TM3

High Channel

5825 MHz

t

Test Mode

Test Conditions
Temperature (℃)

20

Voltage (V)

AC 230V

Special Cable List and Details

LTHV

HTHV

HTLV

-20

-20

55

55

AC 207V

AC 253V

AC 207V

AC 253V

Length (m)

Shielded/Unshielded

With / Without Ferrite

DC Cable

1.0

Unshielded

Without Ferrite

RJ45 Cable

1.0

Unshielded

Without Ferrite

Manufacturer

Model

Serial Number

Lenovo

E10

LR-63C8R

SE
M.
T

Cable Description

LTLV

es

Normal

Auxiliary Equipment List and Details
Description

Notebook

1.6 Measurement Uncertainty
Measurement uncertainty
Parameter

Conditions

Uncertainty

EIRP

Conducted

±0.42dB

Frequency Range

---

±1×10-7

Transmitter Spurious Emissions

Radiated

±5.2dB

Receiver Spurious Emissions

Radiated

±5.2dB

REPORT NO.: STR15098069E-2

PAGE 5 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

1.7 Test Equipment List and Details
Manufacturer
Agilent

E4407B

Serial Number
MY41440400

2016-06-16

Spectrum Analyzer

Agilent

N9020A

US47140102

2016-06-16

Signal Generator

Agilent

83752A

3610A01453

2016-06-16

Power Divider

Weinschel

1506A

PM204

2016-06-16

Spectrum Analyzer

Rohde & Schwarz

FSP

836079/035

2016-06-16

EMI Test Receiver

Rohde & Schwarz

ESVB

825471/005

2016-06-16

Amplifier

Agilent

8447F

3113A06717

2016-06-16

Amplifier

C&D

PAP-1G18

2002

2016-06-16

Broadband Antenna

Schwarz beck

VULB9163

9163-333

2016-06-16

Horn Antenna

ETS

3117

00086197

2016-06-16

DC Power Supply

LW

APR-3003

N/A

2016-06-16

Attenuator

ATTEN

es

Model

ATS100-4-20

Due. Date

/

2016-06-16

SE
M.
T

Description

t

Spectrum Analyzer

REPORT NO.: STR15098069E-2

PAGE 6 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

2. SUMMARY OF TEST RESULTS

EN 300440-1
V1.6.1 (2010-08)

Reference

Description of Test Item

Result

7.1.3

Equivalent Isotropically Radiated Power

Pass

7.2.4

Permitted Range of Operating Frequencies

Pass

7.3.6

Spurious Emissions

Pass

7.4.3

Duty Cycle

Pass

7.5.1

Additional requirements for FHSS equipment

N/A

8.3.5

Receiver Spurious Radiations

Pass

t

Standards

SE
M.
T

es

Pass: The EUT complies with the essential requirements in the standard
Fail: The EUT does not comply with the essential requirements in the standard
N/A: not applicable

REPORT NO.: STR15098069E-2

PAGE 7 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

3. Equivalent Isotropically Radiated Power
3.1 Standard Applicable

SE
M.
T

es

t

According to ETSI EN 300 440-1 section 7.1.3, the effective radiated power shall not exceed the power class
value given in following table:

3.2 Test Procedure

According to section 7.1.2 of the standard EN 300440-1, the test procedure shall be as follows:

1. Using a suitable means, the output of the transmitter shall be connected to the spectrum analyzer, the spectrum
analyzer shall be capable of faithfully reproducing the envelope peaks and the duty cycle of the transmitter output
signal. The observed duty cycle of the transmitter (Tx on/(Tx on + Tx off)) shall be noted as x, (0 < x < 1) and
recorded.
2. The average output power of the transmitter shall be determined using the spectrum analyzer. The observed
value shall be recorded as "A" (in dBm).
3. The e.i.r.p. shall be calculated from the above measured power output A, the observed duty cycle x, and the
applicable antenna assembly gain "G" in dBi, according to the formula:
- P = A + G + 10 log (1/x);
4. The measurement shall be repeated at the lowest, the middle, and the highest frequency of the stated frequency
range.These frequencies shall be recorded. FHSS equipment shall be made to hop continuously to each of these
three frequencies separately. These measurements shall be performed at normal and extreme test conditions.

REPORT NO.: STR15098069E-2

PAGE 8 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

3.3 Summary of Test Results
Test Conditions

Measured Value

Antenna Gain

EIRP

Limit

dBm

dBi

dBm

dBm

Low Channel (5775MHz)
6.52

7

13.52

13.98

LTLV

6.42

7

13.42

13.98

LTHV

6.30

7

13.30

13.98

HTHV

6.09

7

13.09

13.98

HTLV

6.28

7

13.28

13.98

Middle Channel (5805MHz)
5.89

7

12.89

13.98

LTLV

5.85

7

12.85

13.98

LTHV

5.79

7

12.79

13.98

HTHV

5.69

7

12.69

13.98

HTLV

5.76

7

12.76

13.98

7

12.62

13.98

7

12.56

13.98

7

12.59

13.98

es

Normal

t

Normal

High Channel (5825MHz)
5.62

LTLV

5.56

LTHV

5.59

SE
M.
T

Normal

HTHV

5.61

7

12.61

13.98

HTLV

5.46

7

12.46

13.98

REPORT NO.: STR15098069E-2

PAGE 9 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

4. Permitted Range of Operating Frequencies
4.1 Applicable Standard
According to EN 300 440-1 section 7.2

4.2 Test Procedure

es

t

The frequency range of the equipment is determined by the lowest and highest frequencies occupied by the power
envelope in accordance with CEPT/ERC Recommendation 74-01 [2].
fH is the highest frequency of the power envelope, it is the frequency furthest above the frequency of maximum
power
where the output power drops below the level of –75 dBm/Hz spectral power density (-30 dBm if measured in a
30 kHz reference bandwidth) eirp.
fL is the lowest frequency of the power envelope; it is the frequency furthest below the frequency of maximum
power
where the output power drops below the level of –75 dBm/Hz spectral power density (-30 dBm if measured in a
30 kHz reference bandwidth) eirp.

SE
M.
T

According to section 7.2.2 of the standard EN 300440-1, the test procedure shall be as follows:
1. Put the spectrum analyzer in video averaging mode with a minimum of 50 sweeps selected.

2. Select the lowest operating frequency of the equipment under test and activate the transmitter with modulation
applied. The RF emission of the equipment shall be displayed on the spectrum analyzer.
3. Using the marker of the spectrum analyzer, find lowest frequency below the operating frequency at which
spectral power density drops below the required value.
4. Select the highest operating frequency of the equipment under test and find the highest frequency at which the
spectral power density drop below the required value.
5. The difference between the frequencies measured in step 3 and step 4 is the operating frequency range.
The equivalent isotropically radiated power is then calculated from the measured value, the known antenna gain,
relative to an isotropic antenna, and if applicable, any losses due to cables and connectors in the measurement
system.

REPORT NO.: STR15098069E-2

PAGE 10 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

4.3 Test Results/Plots
Test Conditions

Frequencies (MHz) at -30dBm/30kHz (EIRP)
Lowest Frequency (fL)

Highest Frequency (fH)

Normal

5731.16

5868.94

LTLV

5731.24

5868.86

LTHV

5731.24

5868.86

HTHV

5731.16

5868.94

HTLV

5731.16

5868.94

t

The frequency range lies within the band 5725MHz to 5875MHz (fL > 5725MHz and fH < 5875MHz),
fullfit the requirements of the standard.

SE
M.
T

es

Test plots hereby for reference with the normal case:

REPORT NO.: STR15098069E-2

PAGE 11 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

Lowest Frequency Channel Edge for reference:

Highest Frequency Channel Edge for reference:

REPORT NO.: STR15098069E-2

PAGE 12 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

5. Spurious Emissions
5.1 Limit of Spurious Emissions

t

The power of any spurious emission shall not exceed the following values given in the following table.

es

5.2 Test Procedure

The EUT was placed on a nonmetal table which is 1.5 meter above the grounded reference plane and set to work
in normal operation mode. Details refer to EN 300 440-1 subclause 7.3.4.
The EUT was operating at transmitting mode to represent worst case during final qualification test.

SE
M.
T

5.3 Environmental Conditions
Temperature:

23 °C

Relative Humidity:

45%

ATM Pressure:

1014 mbar

5.4 Summary of Test Results/Plots

According to the data sheet, the EUT complied with the EN 300 440 standards, and had the worst margin of:

-5.41 dB at 851.0353 MHz in the Horizontal polarization, High Channel, 3Meters

REPORT NO.: STR15098069E-2

PAGE 13 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

Spurious Emission from 30MHz to 1GHz
Test Mode: Transmitting-Low channel (5775MHz)
Horizontal:

No.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

Factor(dB)

(dBm)

(dBm)

(dB)

1

105.2718

-87.47

17.40

-70.07

-54.00

-16.07

ERP

2

734.4913

-86.97

26.98

-59.99

-54.00

-5.99

ERP

3

875.2470

-87.16

28.42

-58.74

-36.00

-22.74

ERP

REPORT NO.: STR15098069E-2

PAGE 14 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

Factor(dB)

(dBm)

(dBm)

(dB)

1

100.9340

-88.20

17.85

-70.35

-54.00

-16.35

ERP

2

739.6605

-87.62

27.29

-60.33

-54.00

-6.33

ERP

3

827.4934

-86.67

26.91

-59.76

-54.00

-5.76

ERP

SE
M.
T

No.

es

t

Vertical:

REPORT NO.: STR15098069E-2

PAGE 15 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

Test Mode: Transmitting-Middle channel (5805MHz)
Horizontal:

No.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

1

106.0126

-88.06

17.32

-70.74

-54.00

-16.74

ERP

2

401.8385

-87.70

21.88

-65.82

-36.00

-29.82

ERP

3

734.4913

-86.89

26.98

-59.91

-54.00

-5.91

ERP

REPORT NO.: STR15098069E-2

PAGE 16 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

1

99.5281

-88.82

17.83

-70.99

-54.00

-16.99

ERP

2

734.4913

-87.28

26.98

-60.30

-54.00

-6.30

ERP

3

893.8567

-86.84

28.55

-58.29

-36.00

-22.29

ERP

SE
M.
T

No.

es

t

Vertical:

REPORT NO.: STR15098069E-2

PAGE 17 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

Test Mode: Transmitting-High channel (5825MHz)
Horizontal:

No.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

1

103.8055

-88.41

17.55

-70.86

-54.00

-16.86

ERP

2

750.1083

-86.91

26.87

-60.04

-54.00

-6.04

ERP

3

851.0353

-87.11

27.70

-59.41

-54.00

-5.41

ERP

REPORT NO.: STR15098069E-2

PAGE 18 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

1

100.2286

-87.78

17.92

-69.86

-54.00

-15.86

ERP

2

734.4913

-86.52

26.98

-59.54

-54.00

-5.54

ERP

3

851.0353

-87.46

27.70

-59.76

-54.00

-5.76

ERP

SE
M.
T

No.

es

t

Vertical:

REPORT NO.: STR15098069E-2

PAGE 19 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

Spurious Emission Above 1GHz
Frequency

Reading

Correct

Result

Limit

Margin

Polar

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

H/V

Low Channel-5775MHz
11550

-51.43

3.1

-48.33

-30

-18.33

H

17325

-53.45

4.2

-49.25

-30

-19.25

H

11550

-51.27

3.1

-48.17

-30

-18.17

V

17325

-53.75

4.2

-49.55

-30

-19.55

V

t

Middle Channel-5805MHz
-51.28

3.1

-48.18

-30

-18.18

H

17415

-52.73

4.5

-48.23

-30

-18.23

H

11610

-51.36

3.1

-48.26

-30

-18.26

V

17415

-55.53

4.5

-51.03

-30

-21.03

V

-48.16

-30

-18.16

H

-51.04

-30

-21.04

H

-46.27

-30

-16.27

V

-49.96

-30

-19.96

V

es

11610

High Channel-5825MHz
-51.26

3.1

17475

-55.54

4.5

11650

-49.37

3.1

17475

-54.46

4.5

SE
M.
T

11650

Note: Testing is carried out with frequency rang 30MHz to 40 GHz, which above 4th Harmonics are attenuated
more than 20dB below the permissible limits or the field strength is too small to be measured.

REPORT NO.: STR15098069E-2

PAGE 20 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

6. Duty Cycle
6.1 Applicable Standard

SE
M.
T

es

t

Test is conducting under the description of ETSI EN 300 440-1 section 7.4. Where an acknowledgement is
required, the additional transmitter on-time shall be included and declared by the manufacturer.

6.2 Test Procedure

Test is conducting under the description of ETSI EN 300 440-1 section 7.4.2.

6.3 Environmental Conditions
Temperature:

22 °C

Relative Humidity:

45%

ATM Pressure:

1019 mbar

6.4 Summary of Test Results/Plots

For generic use devices operating at frequency range 5725-5875MHz, according to ETSI EN 300 440-1, the duty
cycle is no restriction.

REPORT NO.: STR15098069E-2

PAGE 21 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

7. Receiver Spurious Emissions
7.1 Limit of Spurious Emissions
According to the ETSI EN 300 440-1 section 8.3.5, the power of any spurious emission shall not exceed 2 nW in the
range 25 MHz to 1 GHz and shall not exceed 20 nW on frequencies above 1 GHz.

7.2 Test Procedure

t

The EUT was placed on a nonmetal table which is 1.5 meter above the grounded reference plane and set to work
in receiving operation mode. For more detail please refer to the ETSI EN 300 440-1 section 8.3.4.
The EUT was operating at normal to represent worst case during final qualification test.

Temperature:

22 °C

Relative Humidity:

45%

ATM Pressure:

1019 mbar

7.4 Summary of Test Results/Plots

es

7.3 Environmental Conditions

SE
M.
T

According to the data sheet, the EUT complied with the EN 300 440 standards, and had the worst margin of:

-14.26 dB at 737.0714 MHz in the Vertical polarization, Receiving mode, 3Meters

REPORT NO.: STR15098069E-2

PAGE 22 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

Receiver Spurious Emission From 30MHz To 1GHz
Test Mode: Receiving mode
Horizontal:

No.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

1

43.6585

-71.77

-7.73

-79.50

-57.00

-22.50

ERP

2

56.3948

-71.04

-8.16

-79.20

-57.00

-22.20

ERP

3*

454.3100

-71.70

-2.11

-73.81

-57.00

-16.81

ERP

REPORT NO.: STR15098069E-2

PAGE 23 OF 31

Remark

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

Frequency

Reading

Correct

Result

Limit

Margin

(MHz)

(dBm)

dB

(dBm)

(dBm)

(dB)

1

330.1949

-83.22

6.80

-76.42

-57.00

-19.42

ERP

2

473.8347

-82.08

10.09

-71.99

-57.00

-14.99

ERP

3*

737.0714

-81.44

10.18

-71.26

-57.00

-14.26

ERP

SE
M.
T

No.

es

t

Vertical

Remark

Note: Testing is carried out with frequency rang 30MHz to 10th Harmonics frequency, which above 1GHz are
attenuated more than 20dB below the permissible limits or the field strength is too small to be measured.

REPORT NO.: STR15098069E-2

PAGE 24 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

EXHIBIT 1 - PRODUCT LABELING

t

Proposed CE Label Format

Proposed Label Location on EUT

es

Specifications: Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive
backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. The ‘CE’ marking
must be affixed to the EUT or to its data plate. Where this is not possible or not warranted on account of the nature
of the apparatus, it must be affixed to the packaging, if any, and to the accompanying documents. The ‘CE’
marking must have a height of at least 5 mm. If the ‘CE’ marking is reduced or enlarged the proportions given in
the above graduated drawing must be respected.

SE
M.
T

CE Label Location

REPORT NO.: STR15098069E-2

PAGE 25 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

EXHIBIT 2 - EUT PHOTOGRAPHS

t

EUT View 1

SE
M.
T

WIFI 2.4G Antenna

es

WIFI 5G/5.8G Antenna

EUT View 2

REPORT NO.: STR15098069E-2

PAGE 26 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

EUT View 3

EUT View 4

REPORT NO.: STR15098069E-2

PAGE 27 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

EUT View 5

EUT Housing and Board View 1

REPORT NO.: STR15098069E-2

PAGE 28 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

EUT Housing and Board View 2

REPORT NO.: STR15098069E-2

PAGE 29 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

EXHIBIT 3 - TEST SETUP PHOTOGRAPHS

SE
M.
T

es

t

Spurious Emission Test Setup (Below 1GHz)

Spurious Emission Test Setup (Above 1GHz)

REPORT NO.: STR15098069E-2

PAGE 30 OF 31

RF REPORT

Shenzhen SEM.Test Technology Co., Ltd.

SE
M.
T

es

t

Extreme Conditions Test Setup

***** END OF REPORT *****

REPORT NO.: STR15098069E-2

PAGE 31 OF 31

RF REPORT



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2015:10:08 14:14:21+08:00
Create Date                     : 2015:10:08 14:13:41+08:00
Metadata Date                   : 2015:10:08 14:14:21+08:00
Format                          : application/pdf
Title                           : Microsoft Word - EN 300440
Creator                         : Administrator
Document ID                     : uuid:ad37e71c-e325-4cc1-8b88-1520fa1d0f3e
Instance ID                     : uuid:201889ef-dec2-467d-aa50-4cac490bd8dc
Page Count                      : 31
Author                          : Administrator
EXIF Metadata provided by EXIF.tools

Navigation menu