EMC TEST REPORT

Report No.: EH030518-04

CE EMC TEST REPORT
according to
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-17 V2.1.1 (2009-05)
EN 61000-3-2:2000 EN 61000-3-3:2008
Equipment
: 150N Wireless LAN USB Adapter
Model No.
: EW-7811GLn,EW-7811Un,EW-7811UWn,GWU-H811GLn
Brand Name
: EDIMAX
Filing Type
: Existing Change
Applicant
: EDIMAX TECHNOLOGY CO., LTD
No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei
Hsien, Taiwan
Manufacturer

: EDIMAX TECHNOLOGY CO., LTD

No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei
Hsien, Taiwan

: Mar. 23, 2010
Final Test Date : Mar. 31, 2010
Multiple Listing : Please refer to section 2.3
Received Date

Statement
The test result in this report refers exclusively to the presented test model / sample.
Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full.
The test equipment used to perform the test is calibrated and traceable to NML/ROC.

SPORTON International Inc.
st

No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

SPORTON International Inc.
Report Format Version: a

EMC TEST REPORT

Report No.: EH030518-04

Table of Contents
1 SUMMARY OF THE TEST RESULT .......................................................................................................................2
1.1
1.2
1.3
1.4

Emission Tests.................................................................................................................................................................................... 2
Immunity Tests.................................................................................................................................................................................... 2
Uncertainty.......................................................................................................................................................................................... 2
EMS Performance Criteria Description ................................................................................................................................................ 3

2 GENERAL INFORMATION ......................................................................................................................................4
2.1
2.2
2.3
2.4
2.5

Product Category ................................................................................................................................................................................ 4
Table for Testing Locations ................................................................................................................................................................. 4
Table for Multiple Listing ..................................................................................................................................................................... 4
Table for Supporting Units................................................................................................................................................................... 4
EUT Operation during Test ................................................................................................................................................................. 4

3 EMISSION TESTS RESULT ....................................................................................................................................5
3.1
3.2

AC Power Line Conducted Emissions Measurement........................................................................................................................... 5
Typical Test Setup Layout of Conducted Powerline ............................................................................................................................. 6

4 IMMUNITY TESTS RESULT ....................................................................................................................................9
4.1
4.2

Electrostatic Discharge Immunity Measurement (ESD) ....................................................................................................................... 9
Radio Frequency Electromagnetic Field Immunity Measurement (RS) .............................................................................................. 13

5 LIST OF MEASURING EQUIPMENTS ................................................................................................................. 16
6 TEST LOCATION .................................................................................................................................................. 17
7 TAF CERTIFICATE OF ACCREDITATION .......................................................................................................... 18
APPENDIX A. TEST PHOTOS ........................................................................................................................ A1 ~ A5
APPENDIX B. PHOTOGRAPHS OF EUT ....................................................................................................... B1 ~ B3

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: i of ii
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

History of This Test Report
Original Issue Date: Mar. 04, 2011
Report No.: EH030518-04
□ No additional attachment.
■ Additional attachment were issued as following record:
Attachment No.

Issue Date

Description

EH030518

Apr. 07, 2010

EH030518-03

Sep. 01, 2010

EH030518-04

Mar. 04, 2011

Original.
Update layout and standard version EN 301 489-17 V1.3.2
(2008-04) to EN 301 489-17 V2.1.1 (2009-05).
For EMS tests were retested in this report.
Update standard version EN 61000-3-3:1995/A2:2005 to
EN 61000-3-3:2008.

±1 kV 10 25 4 8

EN 61000-3-2:2000 EN 301 489-1 V1.8.1 (2008-04)
EN 61000-3-3:2008

沒有AE不適用本章節

EN 55022:2006

EN 301 489-17 V2.1.1 (2009-05)

EN 61000-3-2:2006
EN 61000-3-3:2008
EN 61000-4-2:2001
沒有車充不適用本章節

EN 61000-4-3:2006
EN 61000-4-4:2004

本法規不適用本章節

EN 61000-4-5:2006
EN 61000-4-6:2005
EN 61000-4-11:2004

1 2 1
Line to ground: ±0.5kV
0 70 0 ; 10/20 ms
500 ms 5000 ms
20 10

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

EN 301 489-1 V1.8.1 (2008-04)
A (Continuous Phenomena for Transmitter/ Receiver)
B (Transient Phenomena for Transmitter / Receiver)

Page No.
Issued Date

: ii of ii
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

CERTIFICATE OF COMPLIANCE
according to
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-17 V2.1.1 (2009-05)
EN 61000-3-2:2000 EN 61000-3-3:2008
Equipment

: 150N Wireless LAN USB Adapter

Model No.

: EW-7811GLn,EW-7811Un,EW-7811UWn,GWU-H811GLn

Brand Name

: EDIMAX

Applicant

: EDIMAX TECHNOLOGY CO., LTD
No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei Hsien, Taiwan

Sporton International as requested by the applicant to evaluate the EMC performance of the product sample
received on Mar. 23, 2010 would like to declare that the tested sample has been evaluated and found to be in
compliance with the tested rule parts. The data recorded as well as the test configuration specified is true and
accurate for showing the sample’s EMC nature.

____________________________
Wayne Hsu / Vice Manager
Reviewed Data: Jul. 30, 2004

SPORTON International Inc.
st

No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 1 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

1 SUMMARY OF THE TEST RESULT
1.1 Emission Tests
Applicable Standard : EN 301 489-1 V1.8.1 (2008-04)
Part

Test Standard

Description of Test

Result

Under Limit

Complies

8.90 dB

3.1

EN 55022:2006

AC Power Conducted Emissions

-

EN 55022:2006

Telecom Line Conducted Emissions

-

-

-

EN 55022:2006

Radiated Emissions

-

-

-

EN 61000-3-2:2006

Harmonic Current Emissions

-

-

-

EN 61000-3-3:2008

Voltage Fluctuations and Flicker

-

-

1.2 Immunity Tests
Applicable Standard : EN 301 489-1 V1.8.1 (2008-04)
Part

Test Standard

Description of Test

Result

Criteria

4.1

EN 61000-4-2:2001

ESD (EUT of Enclosure)

Complies

A

4.2

EN 61000-4-3:2006

RS (EUT of Enclosure)

Complies

A

-

EN 61000-4-4:2004

EFT (EUT of AC Power Port)

-

-

-

EN 61000-4-4:2004

EFT (EUT of Telecom Port)

-

-

-

EN 61000-4-5:2006

Surge (EUT of AC Power Port)

-

-

-

EN 61000-4-5:2006

Surge (EUT of Telecom Port)

-

-

-

EN 61000-4-6:2005

CS (EUT of AC Power Port)

-

-

-

EN 61000-4-6:2005

CS (EUT of Telecom Port)

-

-

-

EN 61000-4-11:2004

DIP (EUT of AC Power Port)

-

-

1.3 Uncertainty
Test Items

Uncertainty

Remark

Conducted Emissions

±2.3dB

Confidence levels of 95%

Radiated Emissions

±3.7dB

Confidence levels of 95%

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 2 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

1.4 EMS Performance Criteria Description
Criteria

During test

After test

Shall operate as intended.
May show degradation of performance
(see note 1).
Shall be no loss of function.
Shall be no unintentional transmissions.
May show loss of function (one or more).
May show degradation of performance
(see note 1).
No unintentional transmissions.

Shall operate as intended.
Shall be no degradation of performance (see note 2).
Shall be no loss of function.
A
Shall be no loss of stored data or user programmable
functions.
Functions shall be self-recoverable.
Shall operate as intended after recovering.
Shall be no degradation of performance (see note 2).
B
Shall be no loss of stored data or user programmable
functions.
May be loss of function (one or more).
Functions shall be recoverable by the operator.
Shall operate as intended after recovering.
C
Shall be no degradation of performance (see note 2).
NOTE 1: Degradation of performance during the test is understood as a degradation to a level not below a
minimum performance level specified by the manufacturer for the use of the apparatus as intended. In
some cases the specified minimum performance level may be replaced by a permissible degradation
of performance.
If the minimum performance level or the permissible performance degradation is not specified by the
manufacturer then either of these may be derived from the product description and documentation
(including leaflets and advertising) and what the user may reasonably expect from the apparatus if
used as intended.
NOTE 2: No degradation of performance after the test is understood as no degradation below a minimum
performance level specified by the manufacturer for the use of the apparatus as intended. In some
cases the specified minimum performance level may be replaced by a permissible degradation of
performance. After the test no change of actual operating data or user retrievable data is allowed.
If the minimum performance level or the permissible performance degradation is not specified by the
manufacturer then either of these may be derived from the product description and documentation
(including leaflets and advertising) and what the user may reasonably expect from the apparatus if
used as intended.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 3 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

3 EMISSION TESTS RESULT
3.1 AC Power Line Conducted Emissions Measurement
3.1.1

Limit
For this product, which is designed to be connected to the AC power line, the radio frequency voltage that is
conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz
shall not exceed below limits table.
Class A
Frequency (MHz)

QP Limit (dBuV)

AV Limit (dBuV)

0.15~0.5

79

66

0.5~30

73

60

Frequency (MHz)

QP Limit (dBuV)

AV Limit (dBuV)

0.15~0.5

66~56

56~46

0.5~5

56

46

5~30

60

50

Class B

3.1.2

Measuring Instruments and Setting
Please refer to section 5 of equipments list in this report. The following table is the setting of the receiver.

3.1.3

Receiver Parameters

Setting

Attenuation

10 dB

Start Frequency

0.15 MHz

Stop Frequency

30 MHz

IF Bandwidth

9 KHz

Test Procedures
1.

The EUT warm up about 15 minutes then start test.

2.

The EUT or host of EUT has to be placed 0.4 meter far from the conducting wall of the shielding room
and at least 80 centimeters from any other grounded conducting surface.

3.

Connect EUT or host of EUT to the power mains through a line impedance stabilization network (LISN).

4.

All the support units are connected to the other LISNs. The LISN should provide 50uH/50ohms coupling
impedance.

5.

The frequency range from 150 KHz to 30 MHz was searched.

6.

Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold
Mode.

7.

The measurement has to be done between each power line and ground at the power terminal.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 5 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

3.2 Typical Test Setup Layout of Conducted Powerline

10 cm

80 cm to the ground plane

L.I.S.N.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

L.I.S.N.

Page No.
Issued Date

: 6 of 18
: Mar. 04, 2011

EMC TEST REPORT
3.2.1

Report No.: EH030518-04

Results of AC Power Line Conducted Emissions Measurement
Final Test Date

Mar. 23, 2010

Test Site No.

CO01-HY

Temperature

20℃

Humidity

50%

Test Engineer

Steven

Configuration

Normal Mode

Line

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 7 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

Neutral

Note:
Level = Read Level + LISN Factor + Cable Loss.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 8 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

4 IMMUNITY TESTS RESULT
4.1 Electrostatic Discharge Immunity Measurement (ESD)
4.1.1

Limit
Air discharges and contact charges are estimated to enclosure of EUT on all connectors and conducting
surfaces.
Contact Discharges to the conductive surfaces and to coupling planes:
The EUT shall be exposed to at least 20 discharges 10 each at negative and positive polarity.One of the test
points shall be subjected to at least 50 indirect discharges (contact) to the center of the front edge of the
horizontal coupling plane(HCP). The remaining three test points shall each receive at least 50 direct contact
discharges. If no direct contact test points are available, then at least 200 indirect discharges shall be applied
in the indirect mode [see IEC 61000-4-2 for use of the Vertical Conducting Plane (VCP)]. Tests shall be
performed at a maximum repetition rate of one discharge per second.
Air Discharge at seam between apertures and insulation surfaces:
On those parts of the EUT where it is not possible to perform contact discharge testing, the equipment should
be investigated to identify user accessible points where breakdown may occur. This investigation should be
restricted to those areas normally handled by the user. A minimum of 10 single air discharges of each polarity
and test level shall be applied to the selected test point for each area.
The preferential range of test levels for the ESD test is given in following levels:
Contact discharge Test voltage ±4 kV; Air discharge Test voltage ±8 kV
Performance criteria is the criteria B (Transient Phenomena for Transmitter / Receiver).

4.1.2

Measuring Instruments and Setting
Please refer to section 5 of equipments list in this report. The following table is the setting of the electrostatic
discharge simulator.
Electrostatic Discharge Simulator

Discharge Setting

Contact Charge Voltage

±4 kV

Air Charge Voltage

±8 kV

Rise Time

5nS + 30%

Half-Value width

30nS + 30%

Polarity

Positive/Negative

Single Discharge Mode

1 discharge per 1s

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 9 of 18
: Mar. 04, 2011

EMC TEST REPORT
4.1.3

Report No.: EH030518-04

Test Procedures
1.

In the case of air discharge testing the climatic conditions shall be within the following ranges:
Ambient temperature: 15℃ to 35℃;
Relative humidity: 30% to 60%;
Atmospheric pressure: 86 kPa (860 mbar) to 106 kPa (1060 mbar).

2.

Test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT.
The use of special exercising software is encouraged, but permitted only where it can be shown that the
EUT is being comprehensively exercised.

3.

The test voltage shall be increased from the minimum to the selected test severity level, in order to
determine any threshold of failure.

The final severity level should not exceed the product specification

value in order to avoid damage to the equipment.
4.

The test shall be performed with both air discharge and contact discharge. On pre-selected points at
least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On
pre-selected points at least 10 single discharges (in the most sensitive polarity) shall be applied on
contact discharge.

5.

For the time interval between successive single discharges an initial value of one second is
recommended. Longer intervals may be necessary to determine whether a system failure has occurred.

6.

In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the
discharge switch is operated.

7.

In the case of painted surface covering a conducting substrate, the following procedure shall be adopted:
- If the coating is not declared to be an insulating coating by the equipment manufacturer, then the
pointed tip of the generator shall penetrate the coating so as to make contact with the conducting
substrate.
- Coating declared as insulating by the manufacturer shall only be submitted to the air discharge.
- The contact discharge test shall not be applied to such surfaces.

8.

In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as
fast as possible (without causing mechanical damage) to touch the EUT. After each discharge, the ESD
generator (discharge electrode) shall be removed from the EUT. The generator is then re-triggered for a
new single discharge. This procedure shall be repeated until the discharges are completed. In the case
of an air discharge test, the discharge switch, which is used for contact discharge, shall be closed.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 10 of 18
: Mar. 04, 2011

EMC TEST REPORT
4.1.4

Report No.: EH030518-04

Test Setup Layout

A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or
aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm
thickness. In the SPORTON EMC LAB, we provided 1 mm thickness aluminum ground reference plane or 1
mm thickness stainless steel ground reference plane. The minimum size of the ground reference plane is 1 m
x 1 m, the exact size depending on the dimensions of the EUT. It was connected to the protective grounding
system.
The EUT was arranged and connected according to its functional requirements. A distance of 1m minimums
was provided between the EUT and the wall of the lab. And any other metallic structure. In cases where this
length exceeds the length necessary to apply the discharges to the selected points, the excess length shall,
where possible, be placed non-inductively off the ground reference plane and shall not come closer than
0.2m to other conductive parts in the test setup.
Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable with a
470k-ohm resister located at each end, to prevent a build-up of charge. The test setup was consisting a
wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was placed on the
table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm thick. The VCP size,
0.5 m x 0.5 m.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 11 of 18
: Mar. 04, 2011

EMC TEST REPORT
4.1.5

Report No.: EH030518-04

Test Deviation
There is no deviation with the original standard.

4.1.6

Test Result of Electrostatic Discharge Immunity
Final Test Date

Aug. 09, 2010

Test Site

ES01-HY

Temperature

23.9℃

Humidity

51%

Pressure

100 kPa

Test Engineer

Kero

Discharge Mode

Contact Discharge

Test Voltage

±4 kV

Tested No.

10 single
Normal Mode

Required Criteria B

Configuration

Performance

Test Point

Observation

HCP

Criteria

No performance degradation was observed.

A

No performance degradation was observed.

A

(At front, left, right, rear)

VCP
(At front, left, right, rear)

Final Test Date

Aug. 09, 2010

Test Site

ES01-HY

Temperature

23.9℃

Humidity

51%

Pressure

100 kPa

Test Engineer

Kero

Discharge Mode

Air Discharge

Test Voltage

±8 kV

Tested No.

10 single
Normal Mode

Required Criteria B

Configuration

Performance

Test Point

Observation

Criteria

Case

No performance degradation was observed.

A

LED

No performance degradation was observed.

A

USB Port

No performance degradation was observed.

A

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 12 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

4.2 Radio Frequency Electromagnetic Field Immunity Measurement (RS)
4.2.1

Limit
Most electronic equipment is in some manner affected by electromagnetic radiation. RF immunity test entails
subjecting the equipment under test to a uniform field of radiated electromagnetic energy of specified
electromagnetic field strength and frequency and monitoring the functionality of the device as the frequency
is swept over a specified frequency range.
The preferential range of test field strength levels for the RS test is given in following levels:
80~1GHz: 3V/m / 1.4~2.7GHz: 3V/m
Performance criteria is the criteria A (Continuous Phenomena for Transmitter/ Receiver).

4.2.2

Measuring Instruments and Setting
Please refer to section 5 of equipments list in this report. The following table is the setting of the RS Immunity
Test System.

4.2.3

RS Immunity Test System

Setting

Method Used

Bilog antenna and semi-anechoic chamber

Field Strength Exposure

3 V/m

Frequency Range/Modulation

80-1000MHz and 1400-2700 MHz, 80% AM modulation

Antenna Polarization

Vertical & Horizontal

Test Distance

3m

Frequency Steps

1% step

Dwell Time

2.9 sec

Exposures

Front, Back, Left and Right of the EUT

Test Procedures
1.

The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is
then connected to power and signal leads according to pertinent installation instructions.

2.

The Bilog antenna which is enabling the complete frequency range of 80-1000MHz and 1400-2700 MHz
is placed 3m away from the equipment. The required field strength is determined by placing the field
strength meter(s) on top of or directly alongside the equipment under test and monitoring the field
strength meter via a remote field strength indicator outside the enclosure while adjusting the
continuous-wave to the applicable antennae.

3.

The test is normally performed with the generating antenna facing each of four sides of the EUT. The
polarization of the field generated by the bi-conical antenna necessitates testing each position twice,
once with the antenna positioned vertically and again with the antenna positioned horizontally. The
circular polarization of the field from the log-spiral antenna makes a change of position of the antenna
unnecessary.

4.

At each of the above conditions, the frequency range is swept 80-1000MHz and 1400-2700 MHz
pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 13 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be
discretely analyzed.

4.2.4

Test Setup Layout

NOTE: The chamber is compliance with the sixteen points uniform field requirement as stated in IEC
61000-4-3 Section 6.2.
The procedure defined in this part requires the generation of electromagnetic fields within which the test
sample is placed and its operation observed. To generate fields that are useful for simulation of actual (field)
conditions may require significant antenna drive power and the resultant high field strength levels. To comply
with local regulations and to prevent biological hazards to the testing personnel, it is recommended that these
tests be carried out in a shielded enclosure or semi-anechoic chamber.

4.2.5

Test Deviation
There is no deviation with the original standard.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 14 of 18
: Mar. 04, 2011

EMC TEST REPORT
4.2.6

Report No.: EH030518-04

Test Result of Radio Frequency Electromagnetic Field Immunity
Final Test Date

Aug. 09, 2010

Test Site

RS01/02-HY

Temperature

21.8℃

Humidity

52%

Pressure

100 kPa

Test Engineer

Kero

Performance

Required Criteria A

Configuration

Normal Mode

EUT Face Exposed

Observation

Performance

Front

No performance degradation was observed.

A

Back

No performance degradation was observed.

A

Left

No performance degradation was observed.

A

Right

No performance degradation was observed.

A

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 15 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

5 LIST OF MEASURING EQUIPMENTS
Original < Conducted Emissions >
Instrument

Manufacturer

Model No.

Serial No.

Characteristics

Calibration
Date

Remark

EMC Receiver

R&S

ESCS 30

100132

9kHz – 2.75GHz

Sep. 01, 2009

Conduction
(CO01-HY)

LISN

MessTec

NNB-2/16Z

2001/004

9kHz – 30MHz

Jan. 19, 2010

Conduction
(CO01-HY)

LISN
(Support Unit)

MessTec

NNB-2/16Z

2001/009

9kHz – 30MHz

Mar. 01, 2010

Conduction
(CO01-HY)

RF Cable-CON

HUBER+SUHNER

RG213/U

07611832010001

9kHz – 30MHz

May 05, 2009

Conduction
(CO01-HY)

Note: Calibration Interval of instruments listed above is one year.

Update 
Instrument

Manufacturer

ESD Simulator

KEYTEK

Model No.
MZ-15/EC

Serial No.

Characteristics

Calibration Date

Remark

0711355

Air: 0 kV - 15 kV
Contact: 0 kV - 8 kV

Mar. 10, 2010

ESD

Note: Calibration Interval of instruments listed above is one year.
< RS > -- to 1G test
Instrument

Manufacturer

Model No.

Serial No.

Characteristics

Calibration Date

Remark

Probe

ETS-LINDGREN

HI-6005

00052473

0.1 MHz - 5 GHz

Aug. 12, 2009

RS

Amplifier

AR

250W 1000AM1

320482

80 MHz - 1 GHz

Sep. 21, 2009

RS

DUAL
DIRECTIONAL
COUPLER

AMPLIFIER&
RESEARCH

DC7144A

312782

80-1GHz

Sep. 21, 2009

RS

Antenna

FRANKONIA

BTA-L

02002L

26 MHz - 1 GHz

Sep. 21, 2009

RS

Note: Calibration Interval of instruments listed above is one year.

< RS > -- to 3G test
Instrument

Manufacturer

Model No.

Serial No.

Characteristics

Calibration Date

Remark

Amplifier

AMPLIFIER&
RESEARCH

30S1G3

312505

80M~3GHz

Sep. 21, 2009

RS

DUAL
DIRECTIONAL
COUPLER

AMPLIFIER&
RESEARCH

DC6180A

312453

0.8-4.2GHz

Sep. 21, 2009

RS

Antenna

ETS

3115

6744

1GHz - 18 GHz

Sep. 21, 2009

RS

ROHDE&
SCHWARZ

IMS

100007

9kHz~3GHz

Nov. 03, 2009

RS

ROHDE&
SCHWARZ

1168.8004.02

100095

9kHz~3GHz

Nov. 03, 2009

RS

INTEGRATED
MEASUREMENT
SYSTEM
NRP-Z91 POWER
SENSOR 6GHZ

Note: Calibration Interval of instruments listed above is one year.

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 16 of 18
: Mar. 04, 2011

EMC TEST REPORT

6

Report No.: EH030518-04

TEST LOCATION
SHIJR

HWA YA

LINKOU

DUNGHU

JUNGHE

NEIHU

JHUBEI

ADD

:

6Fl., No. 106, Sec. 1, Shintai 5th Rd., Shijr City, Taipei, Taiwan 221, R.O.C.

TEL

:

886-2-2696-2468

FAX

:

886-2-2696-2255

ADD

:

No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

TEL

:

886-3-327-3456

FAX

:

886-3-318-0055

ADD

:

No. 30-2, Dingfu Tsuen, Linkou Shiang, Taipei, Taiwan 244, R.O.C

TEL

:

886-2-2601-1640

FAX

:

886-2-2601-1695

ADD

:

No. 3, Lane 238, Kangle St., Neihu Chiu, Taipei, Taiwan 114, R.O.C.

TEL

:

886-2-2631-4739

FAX

:

886-2-2631-9740

ADD

:

7Fl., No. 758, Jungjeng Rd., Junghe City, Taipei, Taiwan 235, R.O.C.

TEL

:

886-2-8227-2020

FAX

:

886-2-8227-2626

ADD

:

4Fl., No. 339, Hsin Hu 2

TEL

:

886-2-2794-8886

FAX

:

886-2-2794-9777

ADD

:

No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C.

TEL

:

886-3-656-9065

FAX

:

886-3-656-9085

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

nd

Rd., Taipei 114, Taiwan, R.O.C.

Page No.
Issued Date

: 17 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

7 TAF CERTIFICATE OF ACCREDITATION

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

Page No.
Issued Date

: 18 of 18
: Mar. 04, 2011

EMC TEST REPORT

Report No.: EH030518-04

Appendix A. Test Photos

Page No.

: A1 of A5

EMC TEST REPORT

Report No.: EH030518-04

1. Photographs of Conducted Emissions Test Configuration

FRONT VIEW

REAR VIEW

Page No.

: A2 of A5

EMC TEST REPORT

Report No.: EH030518-04

SIDE VIEW

Page No.

: A3 of A5

EMC TEST REPORT

Report No.: EH030518-04

2. Photographs of ESD Immunity Test Configuration

FRONT VIEW

REAR VIEW

Page No.

: A4 of A5

EMC TEST REPORT

Report No.: EH030518-04

3. Photographs of RS Immunity Test Configuration

FRONT VIEW

REAR VIEW

Page No.

: A5 of A5

TEST REPORT

APPENDIX B. Photographs of EUT

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

PAGE NUMBER : B1 OF B3
ISSUED DATE

: Mar. 04, 2011

TEST REPORT

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

PAGE NUMBER : B2 OF B3
ISSUED DATE

: Mar. 04, 2011

TEST REPORT

SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255

PAGE NUMBER : B3 OF B3
ISSUED DATE

: Mar. 04, 2011



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2012:12:14 18:01:27+08:00
Create Date                     : 2011:03:04 14:17:02+08:00
Metadata Date                   : 2012:12:14 18:01:27+08:00
Creator Tool                    : Adobe Acrobat Pro 9.0.0
Format                          : application/pdf
Document ID                     : uuid:068a4f64-c216-4d6b-b3ac-b66aaf96d525
Instance ID                     : uuid:fa496f64-315b-4af6-84b0-e44e8fc1fdfe
Producer                        : Microsoft® Office Word 2007
Page Count                      : 30
Creator                         : Adobe Acrobat Pro 9.0.0
EXIF Metadata provided by EXIF.tools

Navigation menu