EW 7811GLN EH030518 04 EDIMAX 150N Wireless LAN USB Adapter EN301 489 Unprotected
2016-04-11
: Pdf Ew-7811Gln Eh030518-04-Edimax-150N Wireless Lan Usb Adapter-En301 489-Unprotected EW-7811GLN_EH030518-04-EDIMAX-150N_Wireless_LAN_USB_Adapter-EN301_489-unprotected CertsReports 525336 ProductFiles
Open the PDF directly: View PDF .
Page Count: 30
Download | |
Open PDF In Browser | View PDF |
EMC TEST REPORT Report No.: EH030518-04 CE EMC TEST REPORT according to EN 301 489-1 V1.8.1 (2008-04) EN 301 489-17 V2.1.1 (2009-05) EN 61000-3-2:2000 EN 61000-3-3:2008 Equipment : 150N Wireless LAN USB Adapter Model No. : EW-7811GLn,EW-7811Un,EW-7811UWn,GWU-H811GLn Brand Name : EDIMAX Filing Type : Existing Change Applicant : EDIMAX TECHNOLOGY CO., LTD No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei Hsien, Taiwan Manufacturer : EDIMAX TECHNOLOGY CO., LTD No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei Hsien, Taiwan : Mar. 23, 2010 Final Test Date : Mar. 31, 2010 Multiple Listing : Please refer to section 2.3 Received Date Statement The test result in this report refers exclusively to the presented test model / sample. Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full. The test equipment used to perform the test is calibrated and traceable to NML/ROC. SPORTON International Inc. st No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C. SPORTON International Inc. Report Format Version: a EMC TEST REPORT Report No.: EH030518-04 Table of Contents 1 SUMMARY OF THE TEST RESULT .......................................................................................................................2 1.1 1.2 1.3 1.4 Emission Tests.................................................................................................................................................................................... 2 Immunity Tests.................................................................................................................................................................................... 2 Uncertainty.......................................................................................................................................................................................... 2 EMS Performance Criteria Description ................................................................................................................................................ 3 2 GENERAL INFORMATION ......................................................................................................................................4 2.1 2.2 2.3 2.4 2.5 Product Category ................................................................................................................................................................................ 4 Table for Testing Locations ................................................................................................................................................................. 4 Table for Multiple Listing ..................................................................................................................................................................... 4 Table for Supporting Units................................................................................................................................................................... 4 EUT Operation during Test ................................................................................................................................................................. 4 3 EMISSION TESTS RESULT ....................................................................................................................................5 3.1 3.2 AC Power Line Conducted Emissions Measurement........................................................................................................................... 5 Typical Test Setup Layout of Conducted Powerline ............................................................................................................................. 6 4 IMMUNITY TESTS RESULT ....................................................................................................................................9 4.1 4.2 Electrostatic Discharge Immunity Measurement (ESD) ....................................................................................................................... 9 Radio Frequency Electromagnetic Field Immunity Measurement (RS) .............................................................................................. 13 5 LIST OF MEASURING EQUIPMENTS ................................................................................................................. 16 6 TEST LOCATION .................................................................................................................................................. 17 7 TAF CERTIFICATE OF ACCREDITATION .......................................................................................................... 18 APPENDIX A. TEST PHOTOS ........................................................................................................................ A1 ~ A5 APPENDIX B. PHOTOGRAPHS OF EUT ....................................................................................................... B1 ~ B3 SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : i of ii : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 History of This Test Report Original Issue Date: Mar. 04, 2011 Report No.: EH030518-04 □ No additional attachment. ■ Additional attachment were issued as following record: Attachment No. Issue Date Description EH030518 Apr. 07, 2010 EH030518-03 Sep. 01, 2010 EH030518-04 Mar. 04, 2011 Original. Update layout and standard version EN 301 489-17 V1.3.2 (2008-04) to EN 301 489-17 V2.1.1 (2009-05). For EMS tests were retested in this report. Update standard version EN 61000-3-3:1995/A2:2005 to EN 61000-3-3:2008. ±1 kV 10 25 4 8 EN 61000-3-2:2000 EN 301 489-1 V1.8.1 (2008-04) EN 61000-3-3:2008 沒有AE不適用本章節 EN 55022:2006 EN 301 489-17 V2.1.1 (2009-05) EN 61000-3-2:2006 EN 61000-3-3:2008 EN 61000-4-2:2001 沒有車充不適用本章節 EN 61000-4-3:2006 EN 61000-4-4:2004 本法規不適用本章節 EN 61000-4-5:2006 EN 61000-4-6:2005 EN 61000-4-11:2004 1 2 1 Line to ground: ±0.5kV 0 70 0 ; 10/20 ms 500 ms 5000 ms 20 10 SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 EN 301 489-1 V1.8.1 (2008-04) A (Continuous Phenomena for Transmitter/ Receiver) B (Transient Phenomena for Transmitter / Receiver) Page No. Issued Date : ii of ii : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 CERTIFICATE OF COMPLIANCE according to EN 301 489-1 V1.8.1 (2008-04) EN 301 489-17 V2.1.1 (2009-05) EN 61000-3-2:2000 EN 61000-3-3:2008 Equipment : 150N Wireless LAN USB Adapter Model No. : EW-7811GLn,EW-7811Un,EW-7811UWn,GWU-H811GLn Brand Name : EDIMAX Applicant : EDIMAX TECHNOLOGY CO., LTD No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei Hsien, Taiwan Sporton International as requested by the applicant to evaluate the EMC performance of the product sample received on Mar. 23, 2010 would like to declare that the tested sample has been evaluated and found to be in compliance with the tested rule parts. The data recorded as well as the test configuration specified is true and accurate for showing the sample’s EMC nature. ____________________________ Wayne Hsu / Vice Manager Reviewed Data: Jul. 30, 2004 SPORTON International Inc. st No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 1 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 1 SUMMARY OF THE TEST RESULT 1.1 Emission Tests Applicable Standard : EN 301 489-1 V1.8.1 (2008-04) Part Test Standard Description of Test Result Under Limit Complies 8.90 dB 3.1 EN 55022:2006 AC Power Conducted Emissions - EN 55022:2006 Telecom Line Conducted Emissions - - - EN 55022:2006 Radiated Emissions - - - EN 61000-3-2:2006 Harmonic Current Emissions - - - EN 61000-3-3:2008 Voltage Fluctuations and Flicker - - 1.2 Immunity Tests Applicable Standard : EN 301 489-1 V1.8.1 (2008-04) Part Test Standard Description of Test Result Criteria 4.1 EN 61000-4-2:2001 ESD (EUT of Enclosure) Complies A 4.2 EN 61000-4-3:2006 RS (EUT of Enclosure) Complies A - EN 61000-4-4:2004 EFT (EUT of AC Power Port) - - - EN 61000-4-4:2004 EFT (EUT of Telecom Port) - - - EN 61000-4-5:2006 Surge (EUT of AC Power Port) - - - EN 61000-4-5:2006 Surge (EUT of Telecom Port) - - - EN 61000-4-6:2005 CS (EUT of AC Power Port) - - - EN 61000-4-6:2005 CS (EUT of Telecom Port) - - - EN 61000-4-11:2004 DIP (EUT of AC Power Port) - - 1.3 Uncertainty Test Items Uncertainty Remark Conducted Emissions ±2.3dB Confidence levels of 95% Radiated Emissions ±3.7dB Confidence levels of 95% SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 2 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 1.4 EMS Performance Criteria Description Criteria During test After test Shall operate as intended. May show degradation of performance (see note 1). Shall be no loss of function. Shall be no unintentional transmissions. May show loss of function (one or more). May show degradation of performance (see note 1). No unintentional transmissions. Shall operate as intended. Shall be no degradation of performance (see note 2). Shall be no loss of function. A Shall be no loss of stored data or user programmable functions. Functions shall be self-recoverable. Shall operate as intended after recovering. Shall be no degradation of performance (see note 2). B Shall be no loss of stored data or user programmable functions. May be loss of function (one or more). Functions shall be recoverable by the operator. Shall operate as intended after recovering. C Shall be no degradation of performance (see note 2). NOTE 1: Degradation of performance during the test is understood as a degradation to a level not below a minimum performance level specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. If the minimum performance level or the permissible performance degradation is not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect from the apparatus if used as intended. NOTE 2: No degradation of performance after the test is understood as no degradation below a minimum performance level specified by the manufacturer for the use of the apparatus as intended. In some cases the specified minimum performance level may be replaced by a permissible degradation of performance. After the test no change of actual operating data or user retrievable data is allowed. If the minimum performance level or the permissible performance degradation is not specified by the manufacturer then either of these may be derived from the product description and documentation (including leaflets and advertising) and what the user may reasonably expect from the apparatus if used as intended. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 3 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 3 EMISSION TESTS RESULT 3.1 AC Power Line Conducted Emissions Measurement 3.1.1 Limit For this product, which is designed to be connected to the AC power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed below limits table. Class A Frequency (MHz) QP Limit (dBuV) AV Limit (dBuV) 0.15~0.5 79 66 0.5~30 73 60 Frequency (MHz) QP Limit (dBuV) AV Limit (dBuV) 0.15~0.5 66~56 56~46 0.5~5 56 46 5~30 60 50 Class B 3.1.2 Measuring Instruments and Setting Please refer to section 5 of equipments list in this report. The following table is the setting of the receiver. 3.1.3 Receiver Parameters Setting Attenuation 10 dB Start Frequency 0.15 MHz Stop Frequency 30 MHz IF Bandwidth 9 KHz Test Procedures 1. The EUT warm up about 15 minutes then start test. 2. The EUT or host of EUT has to be placed 0.4 meter far from the conducting wall of the shielding room and at least 80 centimeters from any other grounded conducting surface. 3. Connect EUT or host of EUT to the power mains through a line impedance stabilization network (LISN). 4. All the support units are connected to the other LISNs. The LISN should provide 50uH/50ohms coupling impedance. 5. The frequency range from 150 KHz to 30 MHz was searched. 6. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 7. The measurement has to be done between each power line and ground at the power terminal. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 5 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 3.2 Typical Test Setup Layout of Conducted Powerline 10 cm 80 cm to the ground plane L.I.S.N. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 L.I.S.N. Page No. Issued Date : 6 of 18 : Mar. 04, 2011 EMC TEST REPORT 3.2.1 Report No.: EH030518-04 Results of AC Power Line Conducted Emissions Measurement Final Test Date Mar. 23, 2010 Test Site No. CO01-HY Temperature 20℃ Humidity 50% Test Engineer Steven Configuration Normal Mode Line SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 7 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 Neutral Note: Level = Read Level + LISN Factor + Cable Loss. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 8 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 4 IMMUNITY TESTS RESULT 4.1 Electrostatic Discharge Immunity Measurement (ESD) 4.1.1 Limit Air discharges and contact charges are estimated to enclosure of EUT on all connectors and conducting surfaces. Contact Discharges to the conductive surfaces and to coupling planes: The EUT shall be exposed to at least 20 discharges 10 each at negative and positive polarity.One of the test points shall be subjected to at least 50 indirect discharges (contact) to the center of the front edge of the horizontal coupling plane(HCP). The remaining three test points shall each receive at least 50 direct contact discharges. If no direct contact test points are available, then at least 200 indirect discharges shall be applied in the indirect mode [see IEC 61000-4-2 for use of the Vertical Conducting Plane (VCP)]. Tests shall be performed at a maximum repetition rate of one discharge per second. Air Discharge at seam between apertures and insulation surfaces: On those parts of the EUT where it is not possible to perform contact discharge testing, the equipment should be investigated to identify user accessible points where breakdown may occur. This investigation should be restricted to those areas normally handled by the user. A minimum of 10 single air discharges of each polarity and test level shall be applied to the selected test point for each area. The preferential range of test levels for the ESD test is given in following levels: Contact discharge Test voltage ±4 kV; Air discharge Test voltage ±8 kV Performance criteria is the criteria B (Transient Phenomena for Transmitter / Receiver). 4.1.2 Measuring Instruments and Setting Please refer to section 5 of equipments list in this report. The following table is the setting of the electrostatic discharge simulator. Electrostatic Discharge Simulator Discharge Setting Contact Charge Voltage ±4 kV Air Charge Voltage ±8 kV Rise Time 5nS + 30% Half-Value width 30nS + 30% Polarity Positive/Negative Single Discharge Mode 1 discharge per 1s SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 9 of 18 : Mar. 04, 2011 EMC TEST REPORT 4.1.3 Report No.: EH030518-04 Test Procedures 1. In the case of air discharge testing the climatic conditions shall be within the following ranges: Ambient temperature: 15℃ to 35℃; Relative humidity: 30% to 60%; Atmospheric pressure: 86 kPa (860 mbar) to 106 kPa (1060 mbar). 2. Test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. 3. The test voltage shall be increased from the minimum to the selected test severity level, in order to determine any threshold of failure. The final severity level should not exceed the product specification value in order to avoid damage to the equipment. 4. The test shall be performed with both air discharge and contact discharge. On pre-selected points at least 10 single discharges (in the most sensitive polarity) shall be applied on air discharge. On pre-selected points at least 10 single discharges (in the most sensitive polarity) shall be applied on contact discharge. 5. For the time interval between successive single discharges an initial value of one second is recommended. Longer intervals may be necessary to determine whether a system failure has occurred. 6. In the case of contact discharges, the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. 7. In the case of painted surface covering a conducting substrate, the following procedure shall be adopted: - If the coating is not declared to be an insulating coating by the equipment manufacturer, then the pointed tip of the generator shall penetrate the coating so as to make contact with the conducting substrate. - Coating declared as insulating by the manufacturer shall only be submitted to the air discharge. - The contact discharge test shall not be applied to such surfaces. 8. In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as fast as possible (without causing mechanical damage) to touch the EUT. After each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The generator is then re-triggered for a new single discharge. This procedure shall be repeated until the discharges are completed. In the case of an air discharge test, the discharge switch, which is used for contact discharge, shall be closed. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 10 of 18 : Mar. 04, 2011 EMC TEST REPORT 4.1.4 Report No.: EH030518-04 Test Setup Layout A ground reference plane was provided on the floor of the test site. It was a metallic sheet (copper or aluminum) of 0.25 mm, minimum thickness; other metallic may be used but they shall have at least 0.65 mm thickness. In the SPORTON EMC LAB, we provided 1 mm thickness aluminum ground reference plane or 1 mm thickness stainless steel ground reference plane. The minimum size of the ground reference plane is 1 m x 1 m, the exact size depending on the dimensions of the EUT. It was connected to the protective grounding system. The EUT was arranged and connected according to its functional requirements. A distance of 1m minimums was provided between the EUT and the wall of the lab. And any other metallic structure. In cases where this length exceeds the length necessary to apply the discharges to the selected points, the excess length shall, where possible, be placed non-inductively off the ground reference plane and shall not come closer than 0.2m to other conductive parts in the test setup. Where the EUT is installed on a metal table, the table was connected to the reference plane via a cable with a 470k-ohm resister located at each end, to prevent a build-up of charge. The test setup was consisting a wooden table, 0.8m high, standing on the ground reference plane. A HCP, 1.6 m x 0.8 m, was placed on the table. The EUT and cables was isolated from the HCP by an insulating support 0.5 mm thick. The VCP size, 0.5 m x 0.5 m. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 11 of 18 : Mar. 04, 2011 EMC TEST REPORT 4.1.5 Report No.: EH030518-04 Test Deviation There is no deviation with the original standard. 4.1.6 Test Result of Electrostatic Discharge Immunity Final Test Date Aug. 09, 2010 Test Site ES01-HY Temperature 23.9℃ Humidity 51% Pressure 100 kPa Test Engineer Kero Discharge Mode Contact Discharge Test Voltage ±4 kV Tested No. 10 single Normal Mode Required Criteria B Configuration Performance Test Point Observation HCP Criteria No performance degradation was observed. A No performance degradation was observed. A (At front, left, right, rear) VCP (At front, left, right, rear) Final Test Date Aug. 09, 2010 Test Site ES01-HY Temperature 23.9℃ Humidity 51% Pressure 100 kPa Test Engineer Kero Discharge Mode Air Discharge Test Voltage ±8 kV Tested No. 10 single Normal Mode Required Criteria B Configuration Performance Test Point Observation Criteria Case No performance degradation was observed. A LED No performance degradation was observed. A USB Port No performance degradation was observed. A SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 12 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 4.2 Radio Frequency Electromagnetic Field Immunity Measurement (RS) 4.2.1 Limit Most electronic equipment is in some manner affected by electromagnetic radiation. RF immunity test entails subjecting the equipment under test to a uniform field of radiated electromagnetic energy of specified electromagnetic field strength and frequency and monitoring the functionality of the device as the frequency is swept over a specified frequency range. The preferential range of test field strength levels for the RS test is given in following levels: 80~1GHz: 3V/m / 1.4~2.7GHz: 3V/m Performance criteria is the criteria A (Continuous Phenomena for Transmitter/ Receiver). 4.2.2 Measuring Instruments and Setting Please refer to section 5 of equipments list in this report. The following table is the setting of the RS Immunity Test System. 4.2.3 RS Immunity Test System Setting Method Used Bilog antenna and semi-anechoic chamber Field Strength Exposure 3 V/m Frequency Range/Modulation 80-1000MHz and 1400-2700 MHz, 80% AM modulation Antenna Polarization Vertical & Horizontal Test Distance 3m Frequency Steps 1% step Dwell Time 2.9 sec Exposures Front, Back, Left and Right of the EUT Test Procedures 1. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions. 2. The Bilog antenna which is enabling the complete frequency range of 80-1000MHz and 1400-2700 MHz is placed 3m away from the equipment. The required field strength is determined by placing the field strength meter(s) on top of or directly alongside the equipment under test and monitoring the field strength meter via a remote field strength indicator outside the enclosure while adjusting the continuous-wave to the applicable antennae. 3. The test is normally performed with the generating antenna facing each of four sides of the EUT. The polarization of the field generated by the bi-conical antenna necessitates testing each position twice, once with the antenna positioned vertically and again with the antenna positioned horizontally. The circular polarization of the field from the log-spiral antenna makes a change of position of the antenna unnecessary. 4. At each of the above conditions, the frequency range is swept 80-1000MHz and 1400-2700 MHz pausing to adjust the R.F. signal level or to switch oscillators and antenna. The rate of sweep is in the SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 13 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 order of 1.5*10-3 decades/s. The sensitive frequencies or frequencies of dominant interest may be discretely analyzed. 4.2.4 Test Setup Layout NOTE: The chamber is compliance with the sixteen points uniform field requirement as stated in IEC 61000-4-3 Section 6.2. The procedure defined in this part requires the generation of electromagnetic fields within which the test sample is placed and its operation observed. To generate fields that are useful for simulation of actual (field) conditions may require significant antenna drive power and the resultant high field strength levels. To comply with local regulations and to prevent biological hazards to the testing personnel, it is recommended that these tests be carried out in a shielded enclosure or semi-anechoic chamber. 4.2.5 Test Deviation There is no deviation with the original standard. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 14 of 18 : Mar. 04, 2011 EMC TEST REPORT 4.2.6 Report No.: EH030518-04 Test Result of Radio Frequency Electromagnetic Field Immunity Final Test Date Aug. 09, 2010 Test Site RS01/02-HY Temperature 21.8℃ Humidity 52% Pressure 100 kPa Test Engineer Kero Performance Required Criteria A Configuration Normal Mode EUT Face Exposed Observation Performance Front No performance degradation was observed. A Back No performance degradation was observed. A Left No performance degradation was observed. A Right No performance degradation was observed. A SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 15 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 5 LIST OF MEASURING EQUIPMENTS Original < Conducted Emissions > Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark EMC Receiver R&S ESCS 30 100132 9kHz – 2.75GHz Sep. 01, 2009 Conduction (CO01-HY) LISN MessTec NNB-2/16Z 2001/004 9kHz – 30MHz Jan. 19, 2010 Conduction (CO01-HY) LISN (Support Unit) MessTec NNB-2/16Z 2001/009 9kHz – 30MHz Mar. 01, 2010 Conduction (CO01-HY) RF Cable-CON HUBER+SUHNER RG213/U 07611832010001 9kHz – 30MHz May 05, 2009 Conduction (CO01-HY) Note: Calibration Interval of instruments listed above is one year. UpdateInstrument Manufacturer ESD Simulator KEYTEK Model No. MZ-15/EC Serial No. Characteristics Calibration Date Remark 0711355 Air: 0 kV - 15 kV Contact: 0 kV - 8 kV Mar. 10, 2010 ESD Note: Calibration Interval of instruments listed above is one year. < RS > -- to 1G test Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark Probe ETS-LINDGREN HI-6005 00052473 0.1 MHz - 5 GHz Aug. 12, 2009 RS Amplifier AR 250W 1000AM1 320482 80 MHz - 1 GHz Sep. 21, 2009 RS DUAL DIRECTIONAL COUPLER AMPLIFIER& RESEARCH DC7144A 312782 80-1GHz Sep. 21, 2009 RS Antenna FRANKONIA BTA-L 02002L 26 MHz - 1 GHz Sep. 21, 2009 RS Note: Calibration Interval of instruments listed above is one year. < RS > -- to 3G test Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark Amplifier AMPLIFIER& RESEARCH 30S1G3 312505 80M~3GHz Sep. 21, 2009 RS DUAL DIRECTIONAL COUPLER AMPLIFIER& RESEARCH DC6180A 312453 0.8-4.2GHz Sep. 21, 2009 RS Antenna ETS 3115 6744 1GHz - 18 GHz Sep. 21, 2009 RS ROHDE& SCHWARZ IMS 100007 9kHz~3GHz Nov. 03, 2009 RS ROHDE& SCHWARZ 1168.8004.02 100095 9kHz~3GHz Nov. 03, 2009 RS INTEGRATED MEASUREMENT SYSTEM NRP-Z91 POWER SENSOR 6GHZ Note: Calibration Interval of instruments listed above is one year. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 16 of 18 : Mar. 04, 2011 EMC TEST REPORT 6 Report No.: EH030518-04 TEST LOCATION SHIJR HWA YA LINKOU DUNGHU JUNGHE NEIHU JHUBEI ADD : 6Fl., No. 106, Sec. 1, Shintai 5th Rd., Shijr City, Taipei, Taiwan 221, R.O.C. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 ADD : No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C. TEL : 886-3-327-3456 FAX : 886-3-318-0055 ADD : No. 30-2, Dingfu Tsuen, Linkou Shiang, Taipei, Taiwan 244, R.O.C TEL : 886-2-2601-1640 FAX : 886-2-2601-1695 ADD : No. 3, Lane 238, Kangle St., Neihu Chiu, Taipei, Taiwan 114, R.O.C. TEL : 886-2-2631-4739 FAX : 886-2-2631-9740 ADD : 7Fl., No. 758, Jungjeng Rd., Junghe City, Taipei, Taiwan 235, R.O.C. TEL : 886-2-8227-2020 FAX : 886-2-8227-2626 ADD : 4Fl., No. 339, Hsin Hu 2 TEL : 886-2-2794-8886 FAX : 886-2-2794-9777 ADD : No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C. TEL : 886-3-656-9065 FAX : 886-3-656-9085 SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 nd Rd., Taipei 114, Taiwan, R.O.C. Page No. Issued Date : 17 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 7 TAF CERTIFICATE OF ACCREDITATION SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page No. Issued Date : 18 of 18 : Mar. 04, 2011 EMC TEST REPORT Report No.: EH030518-04 Appendix A. Test Photos Page No. : A1 of A5 EMC TEST REPORT Report No.: EH030518-04 1. Photographs of Conducted Emissions Test Configuration FRONT VIEW REAR VIEW Page No. : A2 of A5 EMC TEST REPORT Report No.: EH030518-04 SIDE VIEW Page No. : A3 of A5 EMC TEST REPORT Report No.: EH030518-04 2. Photographs of ESD Immunity Test Configuration FRONT VIEW REAR VIEW Page No. : A4 of A5 EMC TEST REPORT Report No.: EH030518-04 3. Photographs of RS Immunity Test Configuration FRONT VIEW REAR VIEW Page No. : A5 of A5 TEST REPORT APPENDIX B. Photographs of EUT SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 PAGE NUMBER : B1 OF B3 ISSUED DATE : Mar. 04, 2011 TEST REPORT SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 PAGE NUMBER : B2 OF B3 ISSUED DATE : Mar. 04, 2011 TEST REPORT SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 PAGE NUMBER : B3 OF B3 ISSUED DATE : Mar. 04, 2011
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2012:12:14 18:01:27+08:00 Create Date : 2011:03:04 14:17:02+08:00 Metadata Date : 2012:12:14 18:01:27+08:00 Creator Tool : Adobe Acrobat Pro 9.0.0 Format : application/pdf Document ID : uuid:068a4f64-c216-4d6b-b3ac-b66aaf96d525 Instance ID : uuid:fa496f64-315b-4af6-84b0-e44e8fc1fdfe Producer : Microsoft® Office Word 2007 Page Count : 30 Creator : Adobe Acrobat Pro 9.0.0EXIF Metadata provided by EXIF.tools