Fd9c8528 2542 48af B376 7df366f018d7
2017-03-29
: Pdf Fd9C8528-2542-48Af-B376-7Df366F018D7 fd9c8528-2542-48af-b376-7df366f018d7 3 2017 pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
SVC Anatomy & Bridge™ Deployment Bridge™ Occlusion Balloon has proven to be a life-saving technology.1 Procedural planning that considers superior vena cava (SVC) anatomy in relation to the pericardium can help ensure successful deployment and utilization. BC BC SVC Tears Can Be Intra- and Extra-Pericardial • The pericardium extends above the right atrium and covers between 30-45% of the SVC. SVC • TEE may identify an intra-pericardial tear, but not recognize the tear also extends above the pericardium in the SVC. • Tears that extend into both areas can bleed into pericardium and the right chest. • Bleeding in the pericardium should not rule out a tear that extends higher in the SVC. Perica rdium Diagram of the pericardium covering about 1/3 of the SVC. The right atrium (RA) and brachiocephalic vein (BC, also known as the innominate vein) are also shown for reference. RA “When in doubt, inflate Bridge.” - Dr. Roger Carrillo, MD. University of Miami SVC lengths of patient population at University of Miami 93% of patients would be completely covered by the Bridge Balloon. The remaining 7% of patients would be mostly covered by the 8cm Bridge Balloon. Courtesy of Roger Carrillo, MD. 25 23 Number of Patients 20 16 15 93% 22 16 14 13 119 out of 128 patients had SVC lengths that would be completely covered by Bridge. 11 10 5 4 4 0 to 40 40 to 45 45 to 50 50 to 55 55 to 60 60 to 65 65 to 70 70 to 75 75 to 80 80 to 85 SVC Length in mm Bridge is designed to cover the entire length of the SVC, including tears in the intra- and extra-pericardial space. 3 85 to 90 2 90 to 95 95 to 100 STOPS ON AVERAGE 90% OF BLOOD LOSS3 DEPLOYS IN UNDER 2 MINUTES2 30 MINUTES OF ACCEPTABLE HEMOSTASIS4 “I cannot overstate that this is a tool that saves lives.1” - Dr. Roger Carrillo, MD., University of Miami Important Safety Information INDICATIONS The Bridge Occlusion Balloon Catheter is indicated for use for temporary vessel occlusion of the superior vena cava in applications including perioperative occlusion and emergency control of hemorrhage. Any use for procedures other than those indicated in these instructions is not recommended exiting the vasculature at the tear site, result in an inability to place the Bridge Occlusion Balloon Catheter or delay or prevent the ability to achieve occlusion. Lead extraction should be performed at institutions with cardiothoracic surgical capabilities by physicians knowledgeable in the techniques and devices for lead or catheter removal. Complication prevention and management protocols should be in place and routinely practiced. It is strongly suggested that the recommendations for lead management of the Heart Rhythm Society (HRS) and European Heart Rhythm Association (EHRA) be followed for best results. CONTRAINDICATIONS None known. WARNINGS Do not position the Bridge Occlusion Balloon Catheter in a manner that would obstruct the right atrium. Obstruction of the atrium could lead to arrhythmias and/or hemodynamic compromise. Prior to initiating the lead extraction procedure, a Bridge Occlusion Balloon Catheter compatible guidewire should be placed through a venous access site and across the length of the superior vena cava. Attempting to place a compatible guidewire after a venous tear occurs may result in an inability to traverse the superior vena cava with the guidewire, result in the guidewire Failure to observe recommended inflation techniques may result in formation of contrast crystals which could prevent deflation. Do not over-inflate the Bridge Occlusion Balloon Catheter after fully occluding the vessel. Over inflation may result in damage to the vessel Do not exceed the Maximum Inflation Volume. Over inflation may result in damage to the vessel or rupture of the balloon. Occlusion of the superior vena cava beyond 30 minutes is not recommended as this may increase the risk of adverse physiologic or neurologic complications. Refer to the IFU for additional information. Always Reaching Farther Corporate Headquarters The Spectranetics Corporation 9965 Federal Dr., Colorado Springs, CO 80921 Tel: 719-447-2000 • Fax: 719-447-2022 Customer Service: 800-231-0978 German Office Spectranetics Deutschland GmbH Schweinfurter Str. 7 97080 Würzburg, Germany Phone: +49 931/4520080 • Fax: +49 931/45200811 Spectranetics International B.V. Plesmanstraat 6, 3833 LA Leusden The Netherlands Tel: +31 33 4347 050 • Fax: +31 33 4347 051 References 1. Elrod, Jodia. Use of Bridge™ Occlusion Balloon in Lead Extraction: Interview with Dr. Roger Carrillo. EP Lab Digest. November, 2016. 2. Document on file D027562. Bridge can be fully deployed in under one minute (53 seconds) in an animal model when pre-positioned on a guidewire, or in under two minutes (1 minute, 46 seconds) when not pre-positioned. 3. Document on file D027561. When deployed, the Bridge occlusion balloon reduces blood loss by up to 90%, on average, in an animal model of an SVC tear. Testing was conducted in a heparinzed porcine model which has shorter SVC length than is typical in humans. A balloon design scaled for use specifically in the porcine model was used in generating this data. 4. Document on file, D026197. In an animal model with SVC tears up to 3.5 cm, with 2 pacing leads and 1 ICD lead. ©2016 Spectranetics. All Rights Reserved. Approved for External Distribution. D032863-00 112016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29 Create Date : 2016:12:05 12:53:31-07:00 Metadata Date : 2016:12:05 13:49:54-07:00 Modify Date : 2016:12:05 13:49:54-07:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Instance ID : uuid:7d47d3d0-0ea0-4dad-b71b-7c150402b4a5 Original Document ID : xmp.did:bb22bfda-5de4-443e-845a-53847d69ad29 Document ID : xmp.id:cc566e02-127d-48f4-bca6-6555bd438098 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:8ea651c8-a670-4d85-aeee-b2a5f656dd2d Derived From Document ID : xmp.did:8ea651c8-a670-4d85-aeee-b2a5f656dd2d Derived From Original Document ID: xmp.did:bb22bfda-5de4-443e-845a-53847d69ad29 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2016:12:05 12:53:31-07:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Layout : SinglePage Page Count : 2 Creator : Adobe InDesign CC 2015 (Macintosh)EXIF Metadata provided by EXIF.tools