Goodman GMSS92 Specs

2019-02-12

: Pdf Goodman Gmss92 Specs Goodman GMSS92 Specs Forms

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadGoodman GMSS92 Specs
Open PDF In BrowserView PDF
GMSS92 / GCSS92
Single-Stage, Multi-Speed
Gas Furnace
Up to 92% AFUE

Heating Input: 40,000–120,000 BTU/h

Contents

Nomenclature.............................................2
Product Specifications................................ 3
Dimensions.................................................5
Airflow Specifications.................................7
Wiring Diagram.........................................10
Accessories...............................................11

Standard Features

Cabinet Features

•
•
•
•
•
•
•
•

• Designed for multi-position installation —
GMSS92: upflow, horizontal left or right
GCSS92: downflow, horizontal left or right
• Certified for direct vent (2-pipe)
or non-direct vent (1-pipe)
• Easy-to-install top venting with optional side venting —
GMSS92/upflow models only
• Convenient left or right connection
for gas and electrical service
• Cabinet air leakage (QLeak) ≤ 2%
• Heavy-gauge steel cabinet with durable finish
• Foil-faced insulated heat exchanger cabinet
• Airtight solid bottom or side return with
easy-cut tabs for effortless removal in
bottom air-inlet applications

Heavy-duty aluminized-steel tubular heat exchanger
Stainless-steel secondary heat exchanger
Single-stage gas valve
Durable Silicon Nitride igniter
Multi-speed blower motor
Quiet single-speed induced draft blower
Self-diagnostic control board
All models comply with California 40 ng/J
Low NOx emissions standard
• For installation in California’s South Coast Air
Quality Management District (SCAQMD) only:
This furnace does not meet the SCAQMD
Rule 1111 14 ng/J NOx emission limit, and
thus is subject to a mitigation fee of up to
$450. This furnace is not eligible for the
SCAQMD Clean Air Furnace Rebate
Program: www.CleanAirFurnaceRebate.com.
• AHRI Certified; ETL Listed

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger
Limited Warranty (good for as long as you own your home), and 10-Year Parts Limited Warranty, online registration must be
completed within 60 days of installation. Online registration is not required in California or Québec.

SS-GMSS92

www.goodmanmfg.com

9/18
Supersedes 1/18

Nomenclature

G

M

S

S

92

060

3

B

N

**

1

2

3

4

5,6

7,8,9

10

11

12

13,14

Brand

Engineering

G - Goodman® Brand

Major / Minor Revisions
* Not used for inventory control.

Configuration

NOx

M - Upflow/Horizontal

N - Low NOx

C - Downflow/Horizontal
Cabinet Width
Motor

A - 14”

V - Variable Speed ECM / ComfortNet

B - 17½”

C - 21"
D - 24½"

E - Multi-Speed ECM
Maximum CFM

S - Single Speed
Gas Valve

2 - 800 CFM

4 - 1600 CFM

3 - 1200 CFM

5 - 2000 CFM

M - Modulating
MBTU/h

C - Two- Stage
S - Single Stage

040 - 40,000 BTU/h
060 - 60,000 BTU/h

AFUE
97 - 97% AFUE

120 - 120,000 BTU/h
96 - 96% AFUE

92 - 92% AFUE

2

www. goodmanmfg.com

SS-GMSS92

GMSS92 Product Specifications

GMSS92
0403ANA

GMSS92
0402BNA

GMSS92
0603BNA

GMSS92
0803BNA

GMSS92
0804CNA

GMSS92
0805CNA

GMSS92
1004CNA

GMSS92
1005CNA

GMSS92
1205DNA

High Fire Input¹

40,000

40,000

60,000

80,000

80,000

80,000

100,000

100,000

120,000

High Fire Output¹

36,800

36,800

55,200

73,600

73,600

73,600

92,000

92,000

110,400

92

92

92

92

92

92

92

92

92

Temperature Rise Range (°F)

30 - 60

30 - 60

35 - 65

35 - 65

35 - 65

25 - 55

35 - 65

35 - 65

35 - 65

Vent Diameter³

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

3"

No. of Burners

2

2

3

4

4

4

5

5

6

Available AC @ 0.5" ESP

1.5 - 3

1.5 - 3

1.5 - 3

1.5 - 3

3-5

3-5

3-5

3-5

3-5

Size (D x W)

10" x 6"

10" x 8"

10" x 8"

10" x 8"

10" x 10"

11" x 10"

10" x 10"

11" x 10"

11" x 11"

Horsepower @ 1075 RPM

⅓

⅓

⅓

⅓

½

¾

½

¾

¾

Speed

4

4

4

4

4

4

4

4

4

(1) 16 x 25
(side) or
(1) 14 x 25
(bottom)

(1) 16 x 25
(side or
bottom)

(1) 16 x 25
(side or
bottom)

(1) 16 x 25
(side or
bottom)

(1) 16 x 25
(side or
bottom)

(1) 20 x 25
(bottom)
or (2) 16 x 25
(side)

(1) 16 x 25
(side or
bottom)

Min. Circuit Ampacity⁴

9.3

9.6

9.6

9.6

11.7

13.7

11.7

13.7

13.7

Max. Overcurrent Device (amps)⁵

15

15

15

15

15

15

15

15

15

Shipping Weight (lbs)

104

109

112

115

137

138

139

140

152

Heating Data

AFUE²

Circulator Blower

Filter Size (in²) (Qty)

(1) 20 x 25
(1) 20 x 25
(bottom)
(bottom)
or( 2) 16 x 25 or( 2) 16 x 25
(side)
(side)

Electrical Data

¹
²
³

⁴
⁵

Natural Gas BTU/h
DOE AFUE based upon Isolated Combustion System (ICS)
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required).
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.
May use fuses or HACR-type circuit breakers of the same size as noted.

Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½" FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the
National Electrical Code and/or all existing local codes.
• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance
and noise issues.
• For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum
learances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

SS-GMSS92

www.goodmanmfg.com

3

GCSS92 Product Specifications

GCSS92
0402BNA

GCSS92
0603BNA

GCSS92
0804CNA

GCSS92
1005CNA

High Fire Input¹

40,000

60,000

80,000

100,000

High Fire Output¹

36,800

55,200

73,600

92,000

92

92

92

92

Temperature Rise Range (°F)

30 - 60

35 - 65

35 - 65

35 - 65

Vent Diameter³

2" - 3"

2" - 3"

2" - 3"

2" - 3"

No. of Burners

2

3

4

5

Available AC @ 0.5" ESP

1.5 - 3

1.5 - 3

2.5 - 4

2.5 - 4

Size (D x W)

10" x 8"

10" x 8"

10" x 10"

11" x 10"

Horsepower @ 1075 RPM

⅓

⅓

½

¾

Speed

4

4

4

4

Min. Circuit Ampacity⁴

9.6

9.6

11.7

13.7

Max. Overcurrent Device (amps)⁵

15

15

15

15

Shipping Weight (lbs)

109

112

137

140

Heating Data

AFUE²

Circulator Blower

Electrical Data

¹
²
³

⁴
⁵

Natural Gas BTU/h
DOE AFUE based upon Isolated Combustion System (ICS)
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required).
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.
May use fuses or HACR-type circuit breakers of the same size as noted.

Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½" FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the
National Electrical Code and/or all existing local codes.
• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance
and noise issues.
• For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

4

www. goodmanmfg.com

SS-GMSS92

GMSS92 Dimensions

Air
Discharge

Air
Discharge

28¾
Air Intake
2" Pipe

6½
2¾

A

2⅝
2

C

¾

B

Center Dimple
For Alternate
Air Intake Pipe
3" OD Hole
High-Voltage
Electrical Outlet

Left-Side
Drain Trap
Exterior Holes

6½

1⅞

¾

¾

2

19½

Vent/ Flue Pipe
2" PVC

Alternate
Vent/ Flue
Location

Right-Side
Drain Trap
Exterior Holes
High-Voltage
Electrical Outlet

Standard
Gas Supply
Location

Alternate
Gas Supply

34½
31⅞
23

26½

24⅞

23

19⅝

21⅛

19⅝

14
9¼

9¼

5

1½
LEFT SIDE VIEW

5
1⅞
2⅜
2½

Low-voltage
Electrical Outlet

1⅜

2⅜
2½
22

E
Folded Flanges

Unfolded Flanges

23½

Folded Flanges

Air
Discharge
Model

RIGHT SIDE VIEW

1⅞
Low-Voltage
Electrical Outlet

D
Unfolded Flanges
Condensate Drain
Trap Exterior
Connection
(Right or Left Side)
¾ PVC

23

⅞

FRONT VIEW

Air
Return

A

B

C

D

E

14”

12½"

10½"

8⅝"

10⅛"

GMSS920402BNA

17½

16"

13⅞"

12⅛"

13⅝"

GMSS920603BNA

17½”

16"

13⅞"

12⅛"

13⅝"

GMSS920803BNA

17½”

16"

13⅞"

12⅛"

13⅝"

GMSS920804CNA

21"

19½"

17⅜"

16"

17½"

GMSS920805CNA

21"

19½"

17⅜"

16"

17½"

GMSS921004CNA

21"

19½"

17⅜"

16"

17½"

GMSS921005CNA

21"

19½"

17⅜"

16"

17½"

GMSS921205DNA

24½"

23"

20⅞"

19⅜"

20⅞"

GMSS920403ANA

Minimum Clearances to Combustible Materials
Position

Sides

Rear

Front

Bottom

Flue

Top

Upflow

0"

0"

3"

C

0"

1"

Horizontal

6"

0"

3"

C

0"

6"

C = If placed on combustible floor, the floor MUST be wood ONLY.

SS-GMSS92

www.goodmanmfg.com

5

GCSS92 Dimensions

A
B

2⅝
1⅜

C

1⅞

23

6½
2½

1⅝

18¼

1⅞

Alternate Vent/

Low-Voltage
Electrical Outlet

1½
Low-Voltage
Electrical Outlet

14

Alternate Gas

Alternate
Gas Supply

High-Voltage
Electrical Outlet

25⅛

34½
25⅛

14⅞

14¾

14¾

11⅜
4⅛
Drain Trap Holes
Standard Drain Trap

11⅜

6⅞

6⅞

D
Unfolded Flanges

2
2½
3½

28¾

High-Voltage
Electrical Outlet

Air
Discharge

2⅝

Right-Side View

Right Side Exterior
Drain Trap Holes

Air
Return
Model

20⅛
Folded Flanges

2

E
Folded Flanges

Front View

18⅛
Unfolded Flanges

Air
Discharge

Air
Discharge

A

B

C

D

E

GCSS920402BNA

17½"

14⅝"

14"

14½"

16"

GCSS920603BNA

17½"

14⅝"

14"

14½"

16"

GCSS920804CNA

21"

18⅛"

17½"

18"

19½"

GCSS921005CNA

21"

18⅛"

17½"

18"

19½"

Minimum Clearances to Combustible Materials
Position

Sides

Rear

Front

Bottom

Flue

Top

Downflow

0"

0"

3"

NC

0"

1"

Horizontal

6"

0"

3"

C

0"

6"

C = If placed on combustible floor, the floor MUST be wood ONLY.
NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

6

www. goodmanmfg.com

SS-GMSS92

GMSS92 Airflow Data
(CFM & Temperature Rise vs. External Static Pressure)

Model

Motor
Speed
High

0.1

0.2

0.3

CFM

Rise

CFM

Rise

0.4

CFM

Rise

CFM

0.6

0.7

0.8

Rise

CFM

0.5
Rise

CFM

CFM

CFM

3

1260

N/A

1205

N/A

1153

N/A

1081

31

1023

N/A

946

871

790

2.5

1156

N/A

1115

N/A

1074

31

1019

33

959

35

893

817

742

2

1028

33

993

34

959

35

915

36

866

39

810

742

671

1.5

938

36

903

37

873

38

834

40

791

42

746

672

597

High

3

1,498

N/A

1,446

N/A

1,368

N/A

1,302

N/A

1,227

N/A

1,145

1,059

954

Med

2.5

1,223

N/A

1,182

N/A

1,153

30

1,099

31

1,051

32

982

901

813

2

983

35

971

35

945

36

919

37

878

39

813

746

659

Med
GMSS92
0403ANA Med-Lo
Low
GMSS92
0402BNA Med-Lo
Low

1.5

816

42

794

43

758

45

734

46

678

50

637

597

523

High

3

1,494

N/A

1,428

36

1,362

38

1,294

39

1,231

42

1,162

1,076

972

2.5

1,203

42

1,178

43

1,147

45

1,101

46

1,045

49

986

927

831

2

977

52

965

53

939

54

904

57

866

59

801

763

639
596

Med
GMSS92
0603BNA Med-Lo
Low

1.5

801

64

786

65

751

N/A

714

N/A

714

N/A

680

635

High

3

1,459

47

1,397

49

1,339

51

1,270

54

1,202

57

1,107

1,049

952

Med

2.5

1,191

57

1,166

58

1,137

60

1,086

63

1,033

N/A

973

889

797

2

985

N/A

967

N/A

932

N/A

900

N/A

859

N/A

805

731

620

Low

1.5

808

N/A

785

N/A

758

N/A

726

N/A

679

N/A

629

590

513

High

5

2,115

N/A

2,050

N/A

1,973

35

1,915

36

1,810

38

1,695

1,587

1,467

GMSS92
0803BNA Med-Lo

Med
GMSS92
0804CNA Med-Lo
Low
High
Med
GMSS92
0805CNA Med-Lo
Low

4

1,802

38

1,739

39

1,725

40

1,665

41

1,612

42

1,532

1,443

1,320

3.5

1,517

45

1,509

45

1,496

46

1,475

46

1,441

47

1,388

1,304

1,205

3

1,213

56

1,225

56

1,216

56

1,194

57

1,179

58

1,135

1,084

1,005

5

2,284

30

2,231

31

2,170

31

2,103

32

2,037

33

1,945

1,836

1,750

4

1,865

37

1,869

36

1,775

38

1,732

39

1,684

40

1,619

1,548

1,480

3.5

1,594

43

1,571

43

1,530

45

1,492

46

1,454

47

1,414

1,355

1,293

3

1,411

48

1,366

50

1,325

51

1,296

53

1,251

54

1,200

1,147

1,096
1,443

High

5

2,082

41

1,997

43

1,943

44

1,847

46

1,749

49

1,669

1,560

Med

4

1,823

47

1,782

48

1,711

50

1,659

51

1,574

54

1,513

1,402

1,305

3.5

1,565

54

1,545

55

1,529

56

1,487

57

1,441

59

1,365

1,287

1,196

Low

3

1,261

N/A

1237

N/A

1,242

N/A

1,216

N/A

1,179

N/A

1,145

1,098

1,034

High

5

2,137

40

2,073

41

2,031

42

1,949

44

1,879

45

1,811

1,734

1,625

4

1,793

48

1,754

49

1,704

50

1,648

52

1,590

54

1,534

1,451

1,371

3.5

1,558

55

1,518

56

1,477

58

1,425

60

1,376

62

1,316

1,242

1,170

Low

3

1,370

62

1,325

64

1,288

N/A

1,237

N/A

1,191

N/A

1,134

1,086

1,024

High

5

2,256

45

2,192

47

2,133

48

2,054

50

1,986

51

1,907

1,834

1,718

4

1,805

57

1,762

58

1,722

59

1,677

61

1,618

63

1,563

1,507

1,441

GMSS92
1004CNA Med-Lo

Med
GMSS92
1005CNA Med-Lo

Med
GMSS92
1205DNA Med-Lo
Low
¹

External Static Pressure, (Inches Water Column)

Tons
AC¹

3.5

1,565

65

1,513

N/A

1,480

N/A

1,415

N/A

1,392

N/A

1,346

1,269

1,198

3

1,368

N/A

1,326

N/A

1,278

N/A

1,238

N/A

1,208

N/A

1,165

1,093

1,052

at 0.5" ESP

Notes
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters,
this chart assumes both filters are installed.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
The shaded area indicates ranges in excess of maximum static pressure allowed when heating.
• The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same
temperature rise at a particular CFM, while ESP at the CFM will be lower.

Minimum Filter Sizes
GMSS92
0403ANA

Filter Size (in²) (Qty)

(1) 16 x 25
(side) or (1)
14 x 25
(bottom)

GMSS92
0402BNA

GMSS92
0603BNA

GMSS92
0803BNA

GMSS92
0804CNA

(1) 16 x 25 (side or bottom)

GMSS92
0805CNA

GMSS92
1004CNA

(1) 20 x 25 (bottom)
or (2) 16 x 25 (side)

(1) 16 x 25
(side or bottom)

GMSS92
1005CNA

GMSS92
1205DNA

(1) 20 x 25 (bottom)
or (2) 16 x 25 (side)

Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.

SS-GMSS92

www.goodmanmfg.com

7

GCSS92 Airflow Data
(CFM & Temperature Rise vs. External Static Pressure)
Model

Motor
Speed

Tons
AC¹

High

3

Med
GCSS92
0402BNA Med-Lo
Low

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

CFM

CFM

1,400

N/A

1,331

N/A

1,263

N/A

1,189

N/A

1,106

31

1,020

941

843

2.5

1,204

N/A

1,176

N/A

1,121

30

1,072

32

1,002

34

927

853

740

2

1,020

33

998

34

968

35

923

37

880

39

820

739

652

1.5

841

41

827

41

797

43

766

44

727

47

680

634

556

High

3

1,668

31

1,335

38

1,288

40

1,207

42

1,133

45

1,061

955

845

Med

2.5

1,224

42

1,182

43

1,139

45

1,088

47

1,015

50

948

859

759

2

1,030

50

1,005

51

988

52

942

54

893

57

830

751

666

Low

1.5

859

60

830

62

815

63

789

65

751

N/A

693

629

556

High

4

1,770

39

1,645

41

1,610

42

1,528

45

1,437

47

1,340

1,251

1,141

3.5

1,690

40

1,615

42

1,531

45

1,470

46

1,393

49

1,308

1,196

1,099

3

1,612

42

1,540

44

1,472

46

1,398

49

1,306

52

1,223

1,132

1,010

Low

2.5

1,396

49

1,339

51

1,304

52

1,250

55

1,170

58

1,092

1,010

906

High

4

1,793

48

1,699

50

1,610

53

1,533

56

1,461

58

1,363

1,247

1,146

3.5

1,693

50

1,622

53

1,552

55

1,467

58

1,390

61

1,320

1,205

1,083

GCSS92
0603BNA Med-Lo

Med
GCSS92
0804BNA Med-Lo

Med
GCSS92
1005CNA Med-Lo
Low
¹

External Static Pressure, (Inches Water Column)

3

1,632

52

1,546

55

1,493

57

1,415

60

1,332

64

1,257

1,148

1,054

2.5

1,429

60

1,380

62

1,334

64

1,258

N/A

1,199

N/A

1,136

1,041

942

at 0.5" ESP

Notes
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters,
this chart assumes both filters are installed.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
The shaded area indicates ranges in excess of maximum static pressure allowed when heating.
• The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same
temperature rise at a particular CFM, while ESP at the CFM will be lower.

Minimum Filter Sizes
GCSS92
0402BNA

Filter Size (in²) (Qty)

GCSS92
0603BNA

GCSS92
0804CNA

(2) 10 x 20 or (1) 16 x 25 (top return)

GCSS92
1005CNA

(1) 14 x 20 (bottom) or
(1) 20 x 25 (top return)

Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.

8

www. goodmanmfg.com

SS-GMSS92

SS-GMSS92

www.goodmanmfg.com

10

20

30

40

50

60

70

30

80

90

100

40

50

60

700

600 CFM

90

100

2000
2200
2400 CFM

1800

1600

1400

OUTPUT
BTU/HR
x 1000
Output BTU/h
x 1,000

80

1200

1100

1000

900

70

800

Formulas
FORMULAS

110

120

130

CFM x 1.08

140

BTUBTU/h
OUTPUT
1.08
x RISE
Output== CFM
CFM xx1.08
x Rise
BTU OUTPUT
BTU/H Output ÷ CFM
RISE
Rise= =
1.08

BTU
OUTPUT
TEMPERATURE
RISEChart
CHART
BTU
OutputvsVs.
Temperature Rise

150

Temperature Rise Range Chart

9

TEMPERATURE
RISE
Temperature Rise

Wiring Diagram

W

Y

BK

BL

FUSE

PK

3

2

1

6

5

4

9

8

7

BL

12

11

10

YL

GY

OR
GR

OR

GY

24V THERMOSTAT CONNECTIONS

BK

OR

INTEGRATED
CONTROL
MODULE

MV(12)

C

WH

BK

C2

G

C

ID BLOWER
PRESSURE
SWITCH

PS (10)

NO

C

PSO (4)

TO
MICRO

Y

GAS
VALVE

M1

FRONT COVER
PRESSURE SWITCH

HLI (7)

W

HLO (1)
AUXILIARY
LIMIT CONTROLS

R

AUTO RESET
PRIMARY
LIMIT
CONTROL

RO2 (11)
RO1 (5)
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON 40K BTU)
24 VAC

BR

RD

N
O

⚡

R

G

GND

TH (3)

40 VA
TRANSFORMER

WH

BR

-H
AT
HE

BLOWER COMPARTMENT

LINE-H
JUNCTION BOX

PU

GND

DOOR
SWITCH

BK
WH

WH
INDUCED DRAFT
BLOWER

PU
BL
YL

OR
N
O

WH

MA NUAL R ESET RO LLO UT L IMIT CO NTR O L(S)
( SINGLE CONTROL ON 40K BTU )

C2

GND

BL
GR

1 FLASH

GY

C

GAS VALVE

FRONT COVER
PRESSURE SWITCH

N

FLAME
SENSOR

GR

GND

BK

DISCONNECT

HI VOLTAGE (115V)

2 FLASHES = PRESSURE SWITCH STUCK CLOSED

HI VOLTAGE FIELD

3 FLASHES = PRESSURE SWITCH STUCK OPEN
4 FLASHES = OPEN HIGH LIMIT

JUNCTION

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

TERMINAL

6 FLASHES = OPEN ROLLOUT

8 FLASHES = 8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
PK PINK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED

GND

LOW VOLTAGE FIELD

= SYSTEM LOCKOUT (RETRIES EXCEEDED)

7 FLASHES = 7 FLASHES = LOW FLAME SIGNAL

N

WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.

LOW VOLTAGE (24V)

= CONTROL FAILURE

COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK

GND

WH

NO

STEADY ON = NORMAL OPERATION

OFF

JUNCTION
BOX

BR

MI

L

INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION

L

TO 115 VAC / 1Ø / 60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE

24 VAC
HUMIDIFIER

2 CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER

RD

PK

DISCONNECT

TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE

OR

C

ID BLOWER
PRESSURE
SWITCH

WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.

WH

AUTO RE SET
PRIMA RY LIMIT
CO NTR O L

RD

ELECTRONIC
AIR CLEANER

EAC-H

BURNER COMPARTMENT

CIRCULATOR
BLWR

INTEGRATED CONTROL MODULE

CO
OL

OR

AUXILIARY LIMIT
CONTROLS

ID
BLWR

IND

LINE NEUTRALS

GY

OR

CAPACITOR

BL

WH

BK

YL

INTEGRATED CONTROL MODULE

GR
RD
YL

WH

PK

RD

HOT SURFACE
IGNITER

IGN

BK

CIRCULATOR
BLOWER

BR

115 VAC

FS

WH
BK (HI)
BL (MED)
OR (MED LOW)
RD (LOW)

BR

XFMR-H

FLAME SENSOR

1

HEAT-H
LINE-H

GND

WH

PK

2

115 VAC HOT AND PARK TERMINALS
COOL-H

115 VAC NEUTRAL
TERMINALS

XFMR-H

DIAGNOSTIC
LED

EQUIPMENT GND
FIELD GND
FIELD SPLICE
SWITCH (TEMP.)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

115 VAC

TR (6)
GND (8)
MVC (9)

Warning

C

40 VA
TRANSFORMER

INTEGRATED
CONTROL MODULE

HUMIDIFIER

⚠

24 VAC
24V THERMOSTAT
CONNECTIONS

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)

GY

Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring.

OR

24 VAC
HUMIDIFIER

NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTUR'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY.
4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO

AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM.
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

0140F01908-A

10

www. goodmanmfg.com

SS-GMSS92

Accessories

Model

Description

GMSS92
0403ANA

GMSS92
0402BNA

GMSS92
0603BNA

GMSS92
0803BNA

GMSS92
0804CNA

GMSS92
0805CNA

GMSS92
1004CNA

GMSS92
1005CNA

GMSS92
1205DNA

CVENT-2

Concentric Vent Kit (2")

√

√

√

√

√

√

√

√

---

CVENT-3

Concentric Vent Kit (3")

√

√

√

√

√

√

√

√

√

CFSB17

Downflow Sub-Base 17.5"

---

---

---

---

---

---

---

---

---

CFSB21

Downflow Sub-Base 21"

---

---

---

---

---

---

---

---

---

CFSB24

Downflow Sub-Base 24"

---

---

---

---

---

---

---

---

---

RF000142

Drain Kit -Horizontal Left Vertical Flue

√

√

√

√

√

√

√

√

√

EFR02

External Filter Rack with 16"x25"
Permanent Filter

√

√

√

√

√

---

√

---

---

0170K00000S

Flush Mount Vent Kit - 3" or 2"

√

√

√

√

√

√

√

√

√

0170K00001S

Flush Mount Vent Kit - 2"

√

√

√

√

√

√

√

√

---

AFE18-60A

Fossil Fuel (Dual Fuel) Kit

√

√

√

√

√

√

√

√

√

HASFK

High-Altitude Natural Gas Kit

TBD

HASFK-4

HASFK-4

HASFK-4

HASFK-4

HASFK-4

HASFK-4

HASFK-4

HASFK-4

HASFK

High-Altitude LP Gas Kit

TBD

HASFK-4

HASFK-4

HASFK-5

HASFK-4

HASFK-4

HASFK-4

HASFK-5

HASFK-4

LPLP03

Low LP Gas Pressure Switch

√

√

√

√

√

√

√

√

√

LPM-07

LP Conversion Kits

√

√

√

√

√

√

√

√

√

TK-400

Twinning Kit

√

√

√

√

√

√

√

√

√

Model

Description

GCSS92
0402BNA

GCSS92
0603BNA

GCSS92
0804CNA

GCSS92
1005CNA

√
√
√
------√
√
√
√

√
√
√
------√
√
√
√

√
√
--√
----√
√
√
√

√
√
--√
------√
√
√

CVENT-2

Concentric Vent Kit (2")

CVENT-3

Concentric Vent Kit (3")

CFSB17

Downflow Sub-Base 17.5"

CFSB21

Downflow Sub-Base 21"

CFSB24

Downflow Sub-Base 24"

RF000142

Drain Kit -Horizontal Left Vertical Flue

EFR02

External Filter Rack with 16"x25" Permanent Filter

0170K00000S

Flush Mount Vent Kit - 3" or 2"

0170K00001S

Flush Mount Vent Kit - 2"

AFE18-60A

Fossil Fuel (Dual Fuel) Kit

HASFK

High-Altitude Natural Gas Kit

HASFK-4

HASFK-4

HASFK-4

HASFK-4

HASFK

High-Altitude LP Gas Kit

HASFK-4

HASFK-4

HASFK-5

HASFK-4

LPLP03

Low LP Gas Pressure Switch

LPM-07

LP Conversion Kits

TK-400

Twinning Kit

√
√
√

√
√
√

√
√
√

√
√
√

SS-GMSS92

www.goodmanmfg.com

11

Notes

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs
without notice or without incurring obligations. © 2018 Goodman Manufacturing Company, L.P. • Houston, Texas

12

www. goodmanmfg.com

SS-GMSS92



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47
Create Date                     : 2018:09:13 13:27:40-05:00
Modify Date                     : 2018:09:13 13:27:43-05:00
Metadata Date                   : 2018:09:13 13:27:43-05:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Version ID                      : 1
Instance ID                     : uuid:51f6b5f0-d18e-764e-83e9-0de61d84e6d6
Original Document ID            : adobe:docid:indd:2f777e5f-6773-11dc-818f-bda6d96a0b37
Document ID                     : xmp.id:887f7a25-1e76-4f3c-bd24-7cdfdc5610f4
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:dca31bf3-1368-4245-9032-283346368dcf
Derived From Document ID        : xmp.did:a827050c-3fe2-4342-ae6f-3f54f68d06af
Derived From Original Document ID: adobe:docid:indd:2f777e5f-6773-11dc-818f-bda6d96a0b37
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:09:13 13:27:40-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Slug Family                     : Avenir Heavy
Slug Version                    : 8.0
Slug Outline File Size          : 0
Slug Kerning Checksum           : 0
Slug Foundry                    : Linotype AG
Slug Font Kind                  : TrueType Collection
Slug Checksum                   : 1845206366
Slug Post Script Name           : Avenir-HeavyOblique
Slug Font Sense 12 Checksum     : 1845206366
Page Count                      : 12
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu