Attributes

Strength Data
Engineered with HEALIX Dual
Thread Technology™

Pullout Comparison

1

• Dual thread pattern maximizes pull-out
strength2 by independently engaging both
cortical & cancellous bone

100

4.5mm HEALIX Ti Torque Capability

1

24

175

150

Driver/Anchor Hex Strip Failure - 18.70

20

80

110.00

82.90

72.00

74.20

40

Cancellous
Threads

20
0
5.5mm
HEALIX Ti

4.5mm
5.5mm
4.5mm
HEALIX Ti Corkscrew FT* Corkscrew FT*

100

128.3

75
50

5

0
5.5mm HEALIX Ti

16

5.5mm Corkscrew FT*

Driver/Anchor
Hex Strip -12.50

12

• Cannulation channels blood
to the surface

8

12.71

13.88
• Smooth suture bridge provides
improved resistance to
suture abrasion

4

Threads per Anchor Comparison1

125

25

Safe Driver/Handle Strip - 17.60

Insertion Torque [lbf]

60

Cadaveric Perfusion (Flow Rate)1

• Internally driven design provides increased
torque capabilities and insertion confidence2

• Tactile feedback during transition from
cancellous to cortical threads confirms
anchor engagement and security

120

Pullout Force [lbf]

Insertion Torque

Perfusion (cm3/min)

• DePuy Mitek’s evolutionary HEALIX Suture Anchor
is now offered with titanium for added strength

Optimized Fixation in
Rotator Cuff Repair

2.95

Cortical
Threads

3.38

0
4.5mm HEALIX Ti

4.5mm Corkscrew FT*

14
Threads per anchor

12
10

• HEALIX Ti is engineered to engage denser
bone than Arthrex’s Corkscrew FT 1

8

12

6
4

Soft Foam

Hard Foam

Hard Foam

Difference before the force to
insert reaches the force of failure

• Increased number of threads provides
improved bone contact, purchase & bite

4

2

Soft Foam

Suture Bridge

0
5.5mm HEALIX Ti

5.5mm Corkscrew FT*

Suture Abrasion Resistance1

5.5mm HEALIX Ti Torque Capability3
30
25

Trocar Tip Strength

1

Driver/Anchor Hex Strip Failure - 25.00

Insertion Torque [lbf]

250
200
150

1171 Cycles
972 Cycles

20

169 Cycles

15

21.34

10

22.00

4.5mm HEALIX Ti

0

200

400

4.5mm Corkscrew FT
FASTIN®RC
600

800

1000

1200

1400

Suture Abrasion in Number of Suture Cycles to Break

100
50

5.5mm HEALIX Ti

Driver/Anchor Hex Strip - 22.80

300
Tip Separation Force [lbf]

1346 Cycles

242

126

82

0
5.5mm HEALIX Ti

4.5mm HEALIX Ti

FASTIN® RC

• Efficient trocar tip designs allows quick &
easy anchor insertion without the need to
pre-awl, or request additional instruments

5

5.19

5.14

0
5.5mm HEALIX Ti

5.5mm Corkscrew FT*

• ORTHOCORD® Suture now with the
NEW blue striped 3rd suture
- 55 lbs of tensile strength3
- 45% less stiff than Fiberwire**

1600

Mark H. Getelman, M.D.
Co-Director Sports Medicine Fellowship
Southern California Orthopedic Institute

Triple-Loaded HEALIX Ti Techniques
™

Technique I

Introduction - For rotator cuff repairs, there are cases where double row techniques can be beneficial, however, the majority of
cases can be managed well with single row repairs. Several prospective randomized studies have documented equivalent
outcomes with either single or double row repairs4,5,6. In the following, we present different suture options for single row repair.

Technique III

Single-Row Rotator Cuff Repair with HEALIX Ti Triple Loaded Anchor

Pyramid Stitch with HEALIX Ti Triple Loaded Anchor

Blue Striped

Blue

Blue

Purple
Purple

Blue Striped

1

For the simple repair three suture passes
are made per anchor. The medial limb of
each suture closer to the RC is then passed
through the RC using either a shuttle
technique with DePuy Mitek IDEAL™
Suture Graspers or an EXPRESSEW® II
device. The three limbs are equidistantly
spaced apart. Once all sutures are passed
they are sequentially tied using a locking
sliding knot and then follow up with three
alternating half hitches.

Technique II

Blue

2

A lateral microfracture is performed with
a small awl (2-3mm diameter holes by
3-4mm in depth) to promote blood flow
to the healing site (Crimson Duvet).

1

Passes are typically made from posterior to anterior with
the purple stitch as a laterally based wider mattress (pass
1,5) the blue ORTHOCORD® stitch as a narrower and more
medial mattress (pass 2,4) and the blue striped medial limb
passed at the apex (most medial) of the triangle as pass 3.

3

The blue striped ORTHOCORD is then tied over the top of
the medial mattress as a simple stitch.

2

The blue ORTHOCORD sutures are tied first as a medial
mattress (limbs 2 and 4).

4

The second most lateral mattress (purple ORTHOCORD) is lastly
tied over the top of the simple stitch completing the repair. A
microfracture is then performed laterally on the tuberosity to
stimulate blood flow to the surface (Crimson Duvet).

Mason-Alex7 with HEALIX Ti Triple Loaded Anchor

Purple

Blue Striped
Blue Striped

Blue

1

Purple

The two blue striped ORTHOCORD® suture
limbs are passed through the RC as a horizontal mattress with the medial limbs of
the blue and purple passed more medially
and between the mattress. Simply, pass 1 is
posterior lateral and is the blue striped.
Next, pass 2 and 3(purple & blue) are made
as simple passes using more medial limbs
closer to the tissue. Pass 4 is blue striped
and that is anterior lateral.

2

A wide lateral horizontal mattress is created with passes 1 and 4 and the mattress
stitch is then tied first.

3

The two simple stitches are then tied over
the mattress stitch. A microfracture is
then performed laterally on the tuberosity
to stimulate blood flow to the surface
(Crimson Duvet).

IX

AL
HE

m
.5m
4
Ti

IX

AL
HE

mm
5.5
i
T

IX

AL
HE

m
.5m
6
Ti

Pascal Boileau M.D.

3

CUFFLOK Surgical Technique
™

Ordering Information

Department of Orthopaedic Surgery, Hôpital de L’Archet,
University of Nice, Nice, France

TM

Engineered with HEALIX Dual Thread Technology™
1

Insert HEALIX Ti™ Dual Threaded
Suture Anchor adjacent to the articular
margin on the medial tuberosity.

2

Group like colored suture limbs
together and pass either anteriorly
or posteriorly with EXPRESSEW® II
Flexible Suture Passer.

3

Grasp and remove inner suture limbs
(one purple and one blue) together and
tie a secure knot outside the shoulder.

HEALIX Ti product breadth provides versatility
to address the demands from a wide variety of
techniques & tear configurations

PRODUCT#

4

Pull opposite limbs to advance knot
into the subacromial space securing
the medial aspect in a mattress fashion.

5

Place limbs into a VERSALOK® Suture
Anchor. Insert VERSALOK Anchor into the
bone and load deployment gun. Once
sutures are tensioned deploy anchor.

6

Rotate VERSALOK inserter in
a counterclockwise manner to
remove inserter. Cut sutures
and probe final repair.

• Sizes (4.5mm, 5.5mm, 6.5mm)
• Arthroscopic and Needle versions
• Comes preloaded with 2 or 3 strands of ORTHOCORD® Suture

DESCRIPTION

DESCRIPTION

HEALIX Ti™ Anchor
222253
4.5mm HEALIX Ti Anchor w/ORTHOCORD®
222245
5.5mm HEALIX Ti Anchor w/ORTHOCORD
222249
6.5mm HEALIX Ti Anchor w/ORTHOCORD
222242
5.5mm HEALIX Ti Anchor w/ORTHOCORD and Needles
222248
6.5mm HEALIX Ti Anchor w/ORTHOCORD and Needles
222271
4.5mm HEALIX Ti 3-Suture Anchor w/ORTHOCORD
222243
5.5mm HEALIX Ti 3-Suture Anchor w/ORTHOCORD
222241
6.5mm HEALIX Ti 3-Suture Anchor w/ORTHOCORD

VERSALOK®
210808
VERSALOK Anchor w/ ORTHOCORD
214710
Deployment Gun
214711
2.9mm Awl

HEALIX BR™ Anchor
222229
4.5mm HEALIX BR Anchor w/ ORTHOCORD
222233
5.5mm HEALIX BR Anchor w/ ORTHOCORD
222238
6.5mm HEALIX BR Anchor w/ ORTHOCORD
222232
5.5mm HEALIX BR Anchor w/ ORTHOCORD w/ Needles
222239
6.5mm HEALIX BR Anchor w/ ORTHOCORD w/ Needles

NEW Clear Cannula System
214106
5.5mm x 75mm Smooth
214114
7.0mm x 75mm Smooth
214107
5.5mm x 75mm Smooth with Distal Rib
214115
7.0mm x 75mm Smooth with Distal Rib
214104
5.5mm x 55mm Threaded
214118
8.5mm x 55mm Threaded
214108
5.5mm x 75mm Threaded
214116
7.0mm x 75mm Threaded
214120
8.5mm x 75mm Threaded
214110
5.5mm x 90mm Threaded
214122
8.5mm x 90mm Threaded

HEALIX PEEK™ Anchor
222205
4.5mm HEALIX PEEK Anchor w/ ORTHOCORD
222209
5.5mm HEALIX PEEK Anchor w/ ORTHOCRD
222221
6.5mm HEALIX PEEK Anchor w/ ORTHOCORD
222210
5.5mm HEALIX PEEK Anchor w/ ORTHOCORD and Needles
222215
6.5mm HEALIX PEEK Anchor w/ ORTHOCORD and Needles
222207
5.5mm HEALIX PEEK 3-Suture w/ ORTHOCORD
222219
6.5mm HEALIX PEEK 3-Suture w/ ORTHOCORD
HEALIX Instruments (For use with HEALIX BR & HEALIX PEEK)
222223
HEALIX Awl™
222226
4.5mm HEALIX Cortical Awl/Tap™
222251
5.5mm HEALIX Cortical Awl/Tap
222272
4.5mm HEALIX Full Awl/Tap
222224
5.5mm HEALIX Full Awl/Tap
222225
6.5mm HEALIX Full Awl/Tap

ROTATOR CUFF

PRODUCT#

EXPRESSEW® II Flexible Suture Passer
214004
EXPRESSEW II Device
214005
EXPRESSEW II Needles 5/box
270120
Grasper-Grabber Suture/Tendon Grabber

IDEAL™ Suture Shuttle with CHIA™
251001
IDEAL Suture Shuttle, 25º Left
251002
IDEAL Suture Shuttle, 25º Right
251003
IDEAL Suture Shuttle, 45º Left
251004
IDEAL Suture Shuttle, 45º Right
251005
IDEAL Suture Shuttle, 90º Up
251006
IDEAL Suture Shuttle, Straight Hook
251007
IDEAL Suture Shuttle, Straight Crescent
CHIA PERCPASSER™
214101
CHIA PERCPASSER Suture Passer

R E PA I R S Y S T E M S

A
HE

LIX

Ti

mm
5.5

EW
SS
E
PR
EX

II

K
LO

V

SA
ER

*Corkscrew FT is a trademark of Arthrex Inc. Naples FL

5. Grasso A., Milano G., Salvatore M., Falcone G., Deriu L.,

**Fiberwire is a registered trademark of Arthrex, Inc. Naples FL

Fabbriciani C., Single-row versus double-row arthroscopic

1. Data on File at DePuy Mitek, Inc.

rotator cuff repair: a prospective randomized clinical study.

2. Compared with Arthrex Corkscrew FT Anchor.

Arthroscopy. 25(1):4-12, 2009 Jan.

3. Professor Pascal Boileau M.D. et al, The Mattress-Tension-Band (MTB)

6. Franceschi F., Ruzzini L., Longo UG., Martina FM., Zobel BB.,

Technique: A Knotless Double-Row Arthroscopic Rotator Cuff Repair, Shoulder

Maffulli N., Denaro V. Equivalent clinical results of arthroscopic

Concepts 2008 Arthroscopy & Arthroplasty, pp 245, 2008 May.

single-row and double-row suture anchor repair for rotator

4. Burks RT., Crim J., Brown N., Fink B. Greis PE. A prospective randomized

cuff tears: a randomized controlled trial. American Journal of

clinical trial comparing arthroscopic single- and double-row rotator cuff repair:

Sports Medicine. 35(8):1254-60, 2007 Aug.

magnetic resonance imaging and early clinical evaluation. American Journal

7. Castagna A., Garofalo R., Conti M., Borroni M., Snyder SJ.

of Sports Medicine. 37(4):674-82, 2009 Apr.

Arthroscopic rotator cuff repair using a triple-loaded suture
anchor and a modified Mason-Allen technique (Alex stitch).
Arthroscopy. 23(4):440.e1-4, 2007 Apr.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Create Date                     : 2009:10:29 14:47:10-05:00
Creator Tool                    : QuarkXPress(R) 8.1
Modify Date                     : 2009:10:29 14:58:31-04:00
Metadata Date                   : 2009:10:29 14:58:31-04:00
Producer                        : QuarkXPress(R) 8.1
Format                          : application/pdf
Title                           : Layout 1
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Document ID                     : uuid:d7f2b092-879b-514b-ad39-4c75fc7d2543
Instance ID                     : uuid:f4dd446a-392d-614a-b268-22be3a5068d6
Page Count                      : 4
Creator                         : QuarkXPress(R) 8.1
EXIF Metadata provided by EXIF.tools

Navigation menu