All Suture Anchor

	

with IntelliBraid Technology

Introduction

Searching For a Better Option
The ICONIX family of anchors symbolize the next generation of suture anchor technology. The all suture based system
allows for less bone removal during pilot hole creation without compromising pullout strength. The innovative design is
truly the first of its kind.

IntelliBraid Technology
The IntelliBraid Technology creates a bunching effect using targeted compression zones within the implant sheath for optimal fixation.

ICONIX 2,3,25

ICONIX 1
4.5 mm
12.0 mm

8.0 mm
3.0 mm

4.0 mm
Measurements - Before

Measurements - After

Self-Centering Technology
The ICONIX disposable drills feature a unique Self Centering (SC) Technology, to ensure accurate pilot hole placement.

Without SC Technology

With SC Technology

Competitive Advantages
Anchors
• Four all suture configurations
• A completely all suture based implant made of HSS (Force Fiber) and a polyester sheath
• Helps eliminate the possibility of loose bodies in the joint due to anchor breakage

ICONIX 1
1 strand #2 Force Fiber

Use w/1.4mm instrumentation

ICONIX 2
2 strands #2 Force Fiber

Use w/2.3mm instrumentation

Pilot Hole
• Smaller drill allows for minimal bone removal
during pilot hole creation

ICONIX 3
3 strands #2 Force Fiber

Use w/2.3mm instrumentation

Typical
3.0mm Drill Hole

ICONIX 25
2 strands #5 Force Fiber

Use w/2.3mm instrumentation

ICONIX
2.3mm Drill Hole
ICONIX
1.4mm Drill Hole

• More anchors can be placed in smaller footprint

Intelligent Design
• The ICONIX Anchor System is intelligently sized and color coded to reduce risk of human error

1.4mm

2.3mm

Competitive Advantages
Guides
• Smaller drill guides cause less damage to surrounding tissue
• Universal crown tips can be used on the face and rim of the glenoid

• Options when you need them
• The ICONIX Anchor System was specifically designed for both Rotator Cuff and Instability repairs, with curved		
and straight option guides

Rotator Cuff
Straight Short
Instability
2.3mm

Straight

12º

25º

1.4mm

Competitive Advantages
• The ICONIX Anchor System is specifically designed for Hip FAI procedures with curved and straight guide options
• Designed to provide proper guide length during all FAI cases

Hip - FAI
12º Slant

2.3mm

1.4mm

25º Slant

• Directs anchor trajectory away from the acetabular socket
• Unique SLANT mouth helps place anchor closer to the acetabulum rim, allowing for a more anatomic repair

3mm

Technique
Rotator Cuff

Take selected drill guide and place on
bone in preferred position.

Insert the awl or drill into the drill
guide and advance until positive
stop is hit.

Insert anchor, lightly mallet to fully seat the
anchor into the bone until positive stop is
hit. Untether the suture from the inserter
handle. Pull the anchor inserter handle.
Pull on all sutures to set the anchor.

Insert the drill into the drill guide and
advance until positive stop is hit.

Insert anchor, lightly mallet to fully seat the
anchor into the bone until positive stop is
hit. Untether the suture from the inserter
handle. Pull the anchor inserter handle.
Pull on all sutures to set the anchor.

Instability

Take selected drill guide and place on
bone in preferred position.

Hip - FAI

(Instructions for Hip - FAI are same
as for Instability)

Competitive Advantages
Cannulated Obturator
• Cannulated obturators help save time while gaining access to the hip joint

Pull-out Strength1
Anchor
Stryker ICONIX 25
Stryker ICONIX 3
Stryker ICONIX 2
Stryker ICONIX 1
Biomet JuggerKnot
single loaded

Linvatec Y-Knot

single loaded

0	

100	 200	 300	 400	 500	600

Ultimate Pull-out Force (N)
One pound force is approximately equal to 4.5 Newtons

PART NUMBER	

DESCRIPTION

Anchors
3910-500-512

ICONIX 1   with IntelliBraid Technology,  1.4mm Anchor with 1 strand  #2 Force Fiber

3910-500-522

ICONIX 2   with IntelliBraid Technology,  2.3mm Anchor with 2 strands #2 Force Fiber

3910-500-532

ICONIX 3   with IntelliBraid Technology,  2.3mm Anchor with 3 strands #2 Force Fiber

3910-500-525

ICONIX 25 with IntelliBraid Technology,  2.3mm Anchor with 2 strands #5 Force Fiber

Guides
3910-500-550

ICONIX Straight Guide SHORT for 1.4mm anchor

3910-500-551

ICONIX Straight Guide SHORT for 2.3mm anchor

3910-500-552

ICONIX Straight Guide for 1.4mm anchor

3910-500-553

ICONIX 12º Guide for 1.4mm anchor

3910-500-554

ICONIX 25º Guide for 1.4mm anchor

3910-500-555

ICONIX Straight Guide for 2.3mm anchor

3910-500-556

ICONIX 12º Guide for 2.3mm anchor

3910-500-557

ICONIX 25º Guide for 2.3mm anchor

3910-500-558

ICONIX SLANT 12º Guide for 1.4mm anchor

3910-500-559

ICONIX SLANT 25º Guide for 1.4mm anchor

3910-500-560

ICONIX SLANT 12º Guide for 2.3mm anchor

3910-500-561

ICONIX SLANT 25º Guide for 2.3mm anchor

Obturator
3910-500-562

ICONIX Pencil Tip Obturator SHORT for 1.4mm anchor

3910-500-563

ICONIX Pencil Tip Obturator SHORT for 2.3mm anchor

3910-500-564

ICONIX Trocar Tip Obturator for 1.4mm anchor

3910-500-565

ICONIX Trocar Tip Obturator for 2.3mm anchor

3910-500-566

ICONIX Cannulated Bullet Obturator for 1.4mm anchor

3910-500-567

ICONIX Cannulated Bullet Obturator for 2.3mm anchor

Drills / Awl
3910-500-568

ICONIX 1.4mm Disposable Drill

3910-500-569

ICONIX 2.3mm Disposable Drill

3910-500-571

ICONIX 1.4mm Reusable Straight Drill

3910-500-573

ICONIX 2.3mm Reusable Straight Drill

3910-500-574

ICONIX 2.3mm Reusable Awl

Tray
3910-500-575

Multi-System Reusable Tray

References:
Tech Report # RD-12-080
A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular 	
product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be
trained in the use of any particular product before using it in surgery.
The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always 	
refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be
available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.
Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: ICONIX, Stryker. All other trademarks are trademarks of their respective owners or holders.
Force Fiber is a registered trademark of Teleflex Incorporated.
Literature Number: LJPICX-B
MS/GS 09/12
Copyright © 2012 Stryker
Printed in USA

325
325Corporate
CorporateDrive
Drive
Mahwah,
Mahwah,NJ
NJ07430
07430
t:t:201
201831
8315000
5000
www.stryker.com
www.stryker.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2012:09:21 11:47:14-04:00
Metadata Date                   : 2012:09:21 11:48:14-04:00
Modify Date                     : 2012:09:21 11:48:14-04:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:24f7f1d2-92f1-cf4d-8219-2426f803072c
Original Document ID            : xmp.did:496BCBCEDF2068118C14CF41F34D54A8
Document ID                     : xmp.id:018011740720681180838C90A715F925
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:0E338889802068118C1488EEB49F16A7
Derived From Document ID        : xmp.did:0E338889802068118C1488EEB49F16A7
Derived From Original Document ID: xmp.did:496BCBCEDF2068118C14CF41F34D54A8
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2012:09:21 11:47:14-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu