Iconix All Suture Anchor Brochure
Iconix All Suture Anchor Brochure iconix_all_suture_anchor_brochure iconix_all_suture_anchor_brochure 3 2013 pdf 258413772373414384
2013-02-24
: Pdf Iconix All Suture Anchor Brochure iconix_all_suture_anchor_brochure 2 2013 pdf
Open the PDF directly: View PDF .
Page Count: 8
All Suture Anchor
with IntelliBraid Technology
e ICONIX family of anchors symbolize the next generation of suture anchor technology. e all suture based system
allows for less bone removal during pilot hole creation without compromising pullout strength. e innovative design is
truly the rst of its kind.
Introduction
Searching For a Better Option
IntelliBraid Technology
Without SC Technology
e IntelliBraid Technology creates a bunching eect using targeted compression zones within the implant sheath for optimal xation.
Self-Centering Technology
e ICONIX disposable drills feature a unique Self Centering (SC) Technology, to ensure accurate pilot hole placement.
With SC Technology
12.0 mm
Measurements - Aer
ICONIX 1
4.5 mm
3.0 mm
ICONIX 2,3,25
Measurements - Before
4.0 mm
8.0 mm
Competitive Advantages
• Four all suture congurations
• A completely all suture based implant made of HSS (Force Fiber) and a polyester sheath
• Helps eliminate the possibility of loose bodies in the joint due to anchor breakage
ICONIX 1
1 strand #2 Force Fiber
Use w/1.4mm instrumentation
ICONIX 2
2 strands #2 Force Fiber
Use w/2.3mm instrumentation
ICONIX 3
3 strands #2 Force Fiber
Use w/2.3mm instrumentation
ICONIX 25
2 strands #5 Force Fiber
Use w/2.3mm instrumentation
• Smaller drill allows for minimal bone removal
during pilot hole creation
• More anchors can be placed in smaller footprint
Typical
3.0mm Drill Hole
ICONIX
2.3mm Drill Hole
ICONIX
1.4mm Drill Hole
Anchors
Pilot Hole
• e ICONIX Anchor System is intelligently sized and color coded to reduce risk of human error
Intelligent Design
2.3mm1.4mm
Competitive Advantages
• Smaller drill guides cause less damage to surrounding tissue
• Universal crown tips can be used on the face and rim of the glenoid
• Options when you need them
• e ICONIX Anchor System was specically designed for both Rotator Cu and Instability repairs, with curved
and straight option guides
Rotator Cuff
Instability
Straight Short
Straight
12º
25º
2.3mm 1.4mm
Guides
Competitive Advantages
• e ICONIX Anchor System is specically designed for Hip FAI procedures with curved and straight guide options
• Designed to provide proper guide length during all FAI cases
• Directs anchor trajectory away from the acetabular socket
• Unique SLANT mouth helps place anchor closer to the acetabulum rim, allowing for a more anatomic repair
2.3mm 1.4mm
12º Slant
25º Slant
3mm
Hip - FAI
Technique
Rotator Cuff
Instability
Hip - FAI
Take selected drill guide and place on
bone in preferred position.
Insert the awl or drill into the drill
guide and advance until positive
stop is hit.
Insert anchor, lightly mallet to fully seat the
anchor into the bone until positive stop is
hit. Untether the suture from the inserter
handle. Pull the anchor inserter handle.
Pull on all sutures to set the anchor.
Take selected drill guide and place on
bone in preferred position.
Insert the drill into the drill guide and
advance until positive stop is hit.
Insert anchor, lightly mallet to fully seat the
anchor into the bone until positive stop is
hit. Untether the suture from the inserter
handle. Pull the anchor inserter handle.
Pull on all sutures to set the anchor.
(Instructions for Hip - FAI are same
as for Instability)
Pull-out Strength1
Competitive Advantages
Stryker ICONIX 25
Stryker ICONIX 3
Stryker ICONIX 2
Stryker ICONIX 1
Biomet JuggerKnot
single loaded
Linvatec Y-Knot
single loaded
0 100 200 300 400 500 600
Anchor
Ultimate Pull-out Force (N)
One pound force is approximately equal to 4.5 Newtons
• Cannulated obturators help save time while gaining access to the hip joint
Cannulated Obturator
A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular
product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be
trained in the use of any particular product before using it in surgery.
The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always
refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be
available in all markets because product availability is subject to the regulatory and/or medical practices in individual mar-
kets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.
Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trade-
marks or service marks: ICONIX, Stryker. All other trademarks are trademarks of their respective owners or holders.
Force Fiber is a registered trademark of Teleflex Incorporated.
Literature Number: LJPICX-B
MS/GS 09/12
Copyright © 2012 Stryker
Printed in USA
325 Corporate Drive
Mahwah, NJ 07430
t: 201 831 5000
www.stryker.com
325 Corporate Drive
Mahwah, NJ 07430
t: 201 831 5000
www.stryker.com
References:
Tech Report # RD-12-080
PART NUMBER DESCRIPTION
3910-500-512
3910-500-522
3910-500-532
3910-500-525
3910-500-550
3910-500-551
3910-500-552
3910-500-553
3910-500-554
3910-500-555
3910-500-556
3910-500-557
3910-500-558
3910-500-559
3910-500-560
3910-500-561
Obturator
3910-500-562
3910-500-563
3910-500-564
3910-500-565
3910-500-566
3910-500-567
Drills / Awl
3910-500-568
3910-500-569
3910-500-571
3910-500-573
3910-500-574
Tray
3910-500-575
ICONIX 1 with IntelliBraid Technology, 1.4mm Anchorwith 1 strand #2 Force Fiber
ICONIX 2 with IntelliBraid Technology, 2.3mm Anchor with 2 strands #2 Force Fiber
ICONIX 3 with IntelliBraid Technology, 2.3mm Anchor with 3 strands #2 Force Fiber
ICONIX 25 with IntelliBraid Technology, 2.3mm Anchor with 2 strands #5 Force Fiber
ICONIX Straight Guide SHORT for 1.4mm anchor
ICONIX Straight Guide SHORT for 2.3mm anchor
ICONIX Straight Guide for 1.4mm anchor
ICONIX 12º Guide for 1.4mm anchor
ICONIX 25º Guide for 1.4mm anchor
ICONIX Straight Guide for 2.3mm anchor
ICONIX 12º Guide for 2.3mm anchor
ICONIX 25º Guide for 2.3mm anchor
ICONIX SLANT 12º Guide for 1.4mm anchor
ICONIX SLANT 25º Guide for 1.4mm anchor
ICONIX SLANT 12º Guide for 2.3mm anchor
ICONIX SLANT 25º Guide for 2.3mm anchor
ICONIX Pencil Tip Obturator SHORT for 1.4mm anchor
ICONIX Pencil Tip Obturator SHORT for 2.3mm anchor
ICONIX Trocar Tip Obturator for 1.4mm anchor
ICONIX Trocar Tip Obturator for 2.3mm anchor
ICONIX Cannulated Bullet Obturator for 1.4mm anchor
ICONIX Cannulated Bullet Obturator for 2.3mm anchor
ICONIX 1.4mm Disposable Drill
ICONIX 2.3mm Disposable Drill
ICONIX 1.4mm Reusable Straight Drill
ICONIX 2.3mm Reusable Straight Drill
ICONIX 2.3mm Reusable Awl
Multi-System Reusable Tray
Anchors
Guides