JR Clancy Titan Hoist Data Sheet
User Manual: Pdf JR Clancy Titan Hoist-DataSheet
Open the PDF directly: View PDF .
Page Count: 5
Download | ![]() |
Open PDF In Browser | View PDF |
DATA SHEET Titan ® High-Performance Hoist T itan is a high-performance hoist for applications requiring large capacity, speed and/or long travel. Titan is a customizable pre-engineered hoist – it is engineered and manufactured to your requirements yet provides the economic benefits of an “off-the-shelf” system. Capability • Speed: Up to 650 fpm (3.3 m/s) • Travel: Up to 8 lines @ 90 ft. (27.4 m) Up to 10 lines @ 67 ft. (20.4 m) • Gross Capacity: Up to 3,300 lbs. (1,496 kg) • Max batten length: 96 ft. (29.3 m) Features • Integrated gearmotor and brake provide proven reliability and feature an iron case for vibration and noise control. • Reliable head block with nylon sheaves provide long, trouble-free life and meet or exceed wire rope manufacturer recommendations. • Zero-fleet design allows for a compact, efficient hoist. Pre-loaded chase rollers ensure cables stay in grooves. • Quick-connect clamps – upright, underhung, vertical • Encoder for precise target • Quiet operation • Closed loop vector drives provide pinpoint accuracy. • A complete suite of load and safety features is available including slack line, over/under load, and cross-groove detection. Load monitoring, acoustic dampening, and safety covers can also be added. • Steel backbone adapts to your mounting and load requirements. • Center-to-center spacing • ANSI E1.6.1 Compliant page 1 of 5 • Hoists can be mounted vertically or horizontally. For theatres without grids, vertical mounting can save space and offers easier access for maintenance. Titan ® High-Performance Hoist Safety • Dual braking system with a primary brake on the motor and an independent SureBrake® II operating directly on the drum shaft. SureBrake II is spring applied and electrically released for maximum safety. • Emergency-stop system meets NFPA 79 (Electrical Standard for Industrial Machinery) with ramped stops for high speed equipment to reduce mechanical shock loads. • Two levels of limit switches with normal travel and over travel switches using separate, redundant circuits for added safety. • Loft block idlers contain individual grooves to keep lines contained, prevent binding, friction, and eliminate rubbing of adjacent lines. • Touch safe interior of all electrical enclosures guards to prevent contact with live components, per IEC 204-1 Protection. Control Options • Titan works with the entire range of J.R. Clancy motion control systems. Loft Block Options • 1/4" Universal Series upright or underhung • 1/4" 19 Series underhung Batten Termination Options • Trim Chain • Pipe Clamp and Turnbuckle • Batten Trim Plate • Batten Trim Clamp • 1.5” (48 mm) Schedule 40 batten • 1.5” (48 mm) Schedule 80 batten • 1.5” (48 mm) Schedule 40 truss batten page 2 of 5 Batten Options Titan ® High-Performance Hoist 6'-0" (1.83 m) MIN C/C 12'-0" (3.7 m) MAX C/C VERTICAL AND HORIZONTAL INSTALLATIONS SHOWN 1'-6" MIN (457 mm) 1'-0" (305 mm) MIN BETWEEN TITAN BACKBONE AND BOTTOM OF HEADBLOCK 8 LINE: 90'-0" (27.4 m)MAX BATTEN TRAVEL 10 LINE: 67'-0" (20.4 m) MAX BATTEN TRAVEL 8 LINE: 76'-0" (23.2 m) MAX BATTEN LENGTH 10 LINE: 96'-0" (29.3 m) MAX BATTEN LENGTH Product CAD files and other documents available for download on our website. www.jrclancy.com/ titan-high-performancehoist.php Hoist Capacity Hoist Capacity Loading Information Hoist Capacity Hoist self weight 750 lb (340 kg) max 750 lb (340 kg) max page 3 of 5 Loft Block: (Typical of 7) The combined load on the loft blocks associated with a single Titan hoist will not exceed the hoist capacity. Loads may be unevenly distributed on the batten with a maximum load of 750 lb (340 kg) on any individual loft block. Hoists are not recommended to be used for lifting people. Titan ® High-Performance Hoist Titan Riser — Typical CONTROL CONSOLE OPTIONS Power and Wiring Information: Titan is available for virtually any 3-phase voltage worldwide. Control wiring is dependent on your control system. E-STOP STATIONS TO CENTRAL CABINET OR E-STOP SLAVE 1- BELDEN 8469 BY OTHERS EMERGENCY STOP AUTOMATED RIGGING SYSTEM GEN CY EM ACTIVATION WILL STOP AND INHIBIT ALL MOTION ER S T O P CONSOLE OPTIONS: SCENECONTROL 24+ (DESK OR CART-MOUNT) 30' CABLE SCENECONTROL 24 (DESK, PEDESTAL OR CART-MOUNT) 30' CABLE SCENECONTROL 15 (DESK OR PEDESTAL-MOUNT), 30' CABLE ABOVE CONNECTS TO ANY CONTROL POINT AND POWER OUTLET REMOTE E-STOP STATION - COMPACT SIZE: 3.7"Hx3.7"Wx3.2"D LOCATION: 44"AFF, TBD SCENECONTROL 10 (WALL-MOUNT, 19" RACK-MOUNT OR PENDANT WITH 30' CABLE - PENDANT CONNECTS TO ANY CONTROL POINT) REMOTE E-STOP STATION WITH GUARD SIZE: 8.5"Hx6"Wx5.7"D LOCATION: 44"AFF, TBD NOTE: BASE SYSTEM SUPPORTS UP TO FOUR (4) REMOTE E-STOP STATIONS (WITHOUT ANNUNCIATION OR ILLUMINATION) WITHOUT AN E-STOP MASTER. AT LEAST ONE CONSOLE REQUIRED PER SYSTEM. OTHER OPTIONS: CONSOLE PEDESTAL CONSOLE CART 25' CONTROL EXTENSION CABLE CENTRAL CABINET OPTIONS: ONE (1) REQUIRED CONTROL POINT(S) SERVICE: 110-240VAC, 50-60Hz, 1Ă 20A, 2W+GND BY OTHERS SERVICE: 110-240VAC, 50-60Hz, 1Ă 20A, 2W+GND BY OTHERS TO CENTRAL CABINET 1- BELDEN 8468 2- BELDEN 1583A BY OTHERS 1- BELDEN 8468 2- BELDEN 1583A BY OTHERS EMERGENCY STOP AUTOMATED RIGGING SYSTEM ACTIVATION WILL STOP AND INHIBIT ALL MOTION NETWORK 1 E-STOP PORT NETWORK 2 SERVICE: 110-240VAC, 50-60Hz, 1Ă, 20A, 2W+GND BY OTHERS CONTROL POINT SIZE: 6.3"Hx6.3"Wx4.2"D LOCATION: 18" AFF, TBD TO CENTRAL CABINET NETWORK 1 NETWORK 2 E-STOP I/O PORT CONTROL POINT W/ E-STOP SIZE: 8.5"Hx6"Wx5.7"D LOCATION: 44"AFF, TBD CONSOLE POWER OUTLET ON 4" SQUARE COVER ENCLOSURE BY OTHERS LOCATION: 18" AFF, NEAR EACH CONTROL POINT E-STOP MASTER WITH NETWORK SWITCH REQUIRED IF REMOTE E-STOP STATIONS REQUIRE ANNUNCIATION OR ILLUMINATION, OR IF MORE THAN FOUR (4) REMOTE E-STOPS. ONE E-STOP MASTER SUPPORTS UP TO SIXTEEN (16) CONSOLE PORTS AND REMOTE E-STOP STATIONS. SIZE: AS REQUIRED FOR QUANTITY OF AXES AND E-STOPS UNDER CONTROL LOCATION: AS REQUIRED FOR VENUE LAYOUT. NOTE: MINIMUM OF ONE (1) CONTROL POINT (WITH OR WITHOUT REMOTE E-STOP) REQUIRED PER SYSTEM E-STOP RELAY CABINET WITH NETWORK SWITCH: AVAILABLE IF FEWER THAN FOUR E-STOPS WITH NO ANNUNCIATION OR ILLUMINATION SIZE: AS REQUIRED FOR QUANTITY OF AXES UNDER CONTROL LOCATION: AS REQUIRED FOR VENUE LAYOUT TITAN HOIST SYSTEM TITAN HOIST W/ 8' CONTROL AND POWER TAILS 208/380/480VAC 3Ă 50/60Hz HP PER CHART TYPICAL OF NUM (#) PROVIDED FACTORY-WIRED Current Draw Model HP 208 V 380 V 480 V 018-P0220G 1.5 (1.12 kW) 5A 2.8 A 2.2 A 018-P0220R 1.5 (1.12 kW) 5A 2.8 A 2.2 A 018-P1212R 5 (3.73 kW) 14.5 A 5.5 A 6.3 A 018-P1220R 7.5 (5.6 kW) 20 A 11 A 8.7 A 018-P1812R 7.5 (5.6 kW) 20 A 11 A 8.7 A 010-P1817R 10 (7.5 kW) - 28 A 23 A TO CENTRAL CABINET OR E-STOP EXPANSION 1 - BELDEN 8469 PER WIREWAY SECTION 1 - BELDEN 1583A PER HOIST RECEPTACLE (UP TO EIGHT (8) PER WIREWAY SECTION) BY OTHERS HOIST POWER AND CONTROL WIREWAY - EACH SECTION 8.5"H x 5"D x 96"L (MAXIMUM SECTION LENGTH) ADDITIONAL WIREWAY SECTIONS AS REQUIRED CONTROL DN BYPASS FAULT UP UP DOWN OFF ON HC - 100 SC5000 HC-1O0B LOCAL CONTROL PENDANT TYPICAL OF ONE (1) PER CONTROL SYSTEM (TYPICAL) SERVICE: 208-480VAC, 50-60Hz, 3Ă, SINGLE FEED AT 100A MAX. PER WIREWAY SECTION BY OTHERS page 4 of 5 Titan Electrical Requirements E-STOP OVER TRAVEL Titan ® High-Performance Hoist Warranty and Support Three-Year Warranty against defects in materials or workmanship is provided on all J.R. Clancy equipment. Our warranty is contingent on operation by trained personnel and an annual equipment inspection of a J.R. Clancy authorized technician. 24/7 factory technical support with additional service and assistance provided by a worldwide network of J.R. Clancy authorized dealers. Inspection and maintenance are available through J.R. Clancy’s T.I.M.® (Training, Inspection, Maintenance) Program. Ordering Information Model Number Hoist Speed Hoist Capacity 018-T0224 20 fpm (0.1 m/s) 2,400 lb (1,089 kg) 018-T0233 20 fpm (0.1 m/s) 3,300 lb (1,497 kg) 018-T2022 200 fpm (1.0 m/s) 2,200 lb (998 kg) 018-T2030 200 fpm (1.0 m/s) 3,000 lb (1,361 kg) 018-T2633 260 fpm (1.3 m/s) 3,300 lb (1,497 kg) 018-T3413 340 fpm (1.7 m/s) 1,300 lb (590 kg) 018-T3417 340 fpm (1.7 m/s) 1,750 lb (794 kg) 018-T4022 400 fpm (2.0 m/s) 2,200 lb (998 kg) 018-T6514 650 fpm (3.3 m/s) 1,400 lb (635 kg) Additional Information For more information on Titan, visit www.jrclancy.com to access: • Detailed structural loading • Specifications • Electrical risers diagrams WENGER CORPORATION Phone 800.4WENGER (493-6437) Worldwide +1.507.455.4100 | Parts & Service 800.887.7145 | Canada Office 800.268.0148 | wengercorp.com 555 Park Drive, PO Box 448 | Owatonna MN 55060-0448 J.R. CLANCY Phone 800.836.1885 Worldwide +1.315.451.3440 | jrclancy.com | 7041 Interstate Island Road | Syracuse NY 13209-9713 GEARBOSS Phone 800.493.6437 | email gearboss@wengercorp.com | gearboss.com | 555 Park Drive, PO Box 448 | Owatonna MN 55060-0448 page 5 of 5 © 2018 Wenger Corporation USA/2018-02/W
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2018:03:14 17:20:43-05:00 Creator : Adobe InDesign CC 13.0 (Macintosh) Modify Date : 2018:03:19 14:50:16-05:00 Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2018:03:19 14:50:16-05:00 Creator Tool : Adobe InDesign CC 13.0 (Macintosh) Instance ID : uuid:6c5603d3-e6f2-4e25-9e33-03714ae5dea5 Original Document ID : xmp.did:41b729a9-de69-447a-af27-5732bc2f5ecd Document ID : xmp.id:5a97fbf1-8519-4e5b-bea0-c5505cfa67d6 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:a1eab837-0cff-47f7-a38b-6ac182b2299d Derived From Document ID : xmp.did:4beb6a16-c831-4a12-92e6-4afa01c66e50 Derived From Original Document ID: xmp.did:41b729a9-de69-447a-af27-5732bc2f5ecd Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.0 (Macintosh) History Changed : / History When : 2018:03:14 17:20:43-05:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Mode : UseThumbs Page Count : 5EXIF Metadata provided by EXIF.tools