SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

EMC TEST REPORT
For
Dongguan Juling Electronics Technology Co., Ltd.
Bluetooth Headphone
Model No.: HE09
Additional Model No.: HE01, HE02, HE03, HE04, HE05, HE08, HE14, HE16

Prepared for
Address

: Dongguan Juling Electronics Technology Co., Ltd.
: Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China

Prepared by
Address

: Shenzhen LCS Compliance Testing Laboratory Ltd.
: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an
District, Shenzhen, Guangdong, China

Date of receipt of test sample
Number of tested samples
Serial number
Date of Test
Date of Report

:
:
:
:
:

January 14, 2014
1
Prototype
January 14, 2014 - January 22, 2014
January 22, 2014

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 1 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

EMC TEST REPORT
ETSI EN 301 489-17 V2.2.1 (2012-09)
Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility
(EMC)standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission
Systems
Report Reference No..................

: LCS140114249TE

Date of Issue.................................

: January 22, 2014

Testing Laboratory Name..........

: Shenzhen LCS Compliance Testing Laboratory Ltd.

Address.........................................
Testing Location/ Procedure.........

1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
Bao'an District, Shenzhen, Guangdong, China
Full application of Harmonised standards ■
: Partial application of Harmonised standards □
Other standard testing method □
:

Applicant’s Name .......................

: Dongguan Juling Electronics Technology Co., Ltd.

Address.........................................

: Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong,
China

Test Specification

Test Report Form No. .................

ETSI EN 301 489-1 V1.9.2 (2011-09)
ETSI EN 301 489-17 V2.2.1 (2012-09)
: LCSEMC-1.0

TRF Originator.............................

: Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF ..................................

: Dated 2011-03

Standard........................................

:

Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
Test Item Description ...............

: Bluetooth Headphone

Trade Mark ...................................

: N/A

Model/ Type reference .................

: HE09

Ratings..........................................

:

Result ………………………......

: Positive

DC 3.7V by battery(360mAh)
Recharge Voltage: DC 5V/0.22A

Compiled by:

Supervised by:

Approved by:

Tree Zhan/ File administrators

Fox Zhang/ Technique principal

Gavin Liang/ Manager

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 2 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

EMC -- TEST REPORT

Test Report No. : LCS140114249TE

January 22, 2014
Date of issue

Type / Model........................... : HE09
EUT......................................... : Bluetooth Headphone
Applicant............................... : Dongguan Juling Electronics Technology Co., Ltd.
Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City,
Guangdong, China
Telephone............................... : /
Fax.......................................... : /
Manufacturer........................ : Dongguan Juling Electronics Technology Co., Ltd.
Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City,
Guangdong, China
Telephone............................... : /
Fax.......................................... : /
Factory................................... : Dongguan Juling Electronics Technology Co., Ltd.
Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City,
Guangdong, China
Telephone............................... : /
Fax.......................................... : /

Test Result:

Positive

The test report merely corresponds to the test sample.
It is not permitted to copy extracts of these test result without the written permission of the test
laboratory.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 3 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

TABLE OF CONTENTS
1. GENERAL INFORMATION ..................................................................................................................5
1.1. PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................. 5
1.2. OBJECTIVE ................................................................................................................................................ 5
1.3. RELATED SUBMITTAL(S)/GRANT(S) ......................................................................................................... 5
1.4. TEST METHODOLOGY ............................................................................................................................... 5
1.5. FACILITIES ................................................................................................................................................ 5
1.6. SUPPORT EQUIPMENT LIST ........................................................................................................................ 6
1.7. EXTERNAL I/O.......................................................................................................................................... 6
1.8. LABORATORY ACCREDITATIONS AND LISTINGS....................................................................................... 6
1.9. MEASUREMENT UNCERTAINTY ................................................................................................................ 6
1.10. DESCRIPTION OF TEST MODES ............................................................................................................... 6
2. SUMMARY OF TEST RESULTS...........................................................................................................7
3. RADIATED DISTURBANCE.................................................................................................................8
3.1. RADIATED EMISSION LIMIT ...................................................................................................................... 8
3.2. TEST EQUIPMENT...................................................................................................................................... 8
3.3. TEST CONFIGURATION .............................................................................................................................. 9
3.4. TEST PROCEDURE ..................................................................................................................................... 9
3.5. TEST DATA ............................................................................................................................................... 9
4. GENERAL PERFORMANCE CRITERIA FOR IMMUNITY TEST ..............................................12
4.1. PERFORMANCE CRITERIA FOR CONTINUOUS PHENOMENA APPLIED TO TRANSMITTER (CT) ................... 12
4.2. PERFORMANCE CRITERIA FOR TRANSIENT PHENOMENA APPLIED TO TRANSMITTER (TT)....................... 12
4.3. PERFORMANCE CRITERIA FOR CONTINUOUS PHENOMENA APPLIED TO RECEIVER (CR).......................... 12
4.4. PERFORMANCE CRITERIA FOR TRANSIENT PHENOMENA APPLIED TO RECEIVER (TR) ............................. 12
5. ETSI EN 301 489-17 V2.2.1 §7.2 – RF ELECTROMAGNETIC FIELD (80 MHz -1000 MHz and 1400
MHz –2700 MHz) .......................................................................................................................................13
5.1. TEST EQUIPMENT.................................................................................................................................... 13
5.2. TEST CONFIGURATION ............................................................................................................................ 13
5.3. TEST STANDARD ..................................................................................................................................... 14
5.4. TEST PROCEDURE ................................................................................................................................... 14
5.5. TEST DATA ............................................................................................................................................. 14
6. ELECTROSTATIC DISCHARGE .......................................................................................................16
6.1. TEST EQUIPMENT.................................................................................................................................... 16
6.2. TEST CONFIGURATION ............................................................................................................................ 16
6.3. TEST PROCEDURE ................................................................................................................................... 17
6.4. TEST DATA ............................................................................................................................................. 17
7. TEST SETUP PHOTOGRAPHS ..........................................................................................................19
7.1.PHOTO OF RADIATED MEASUREMENT ..................................................................................................... 19
7.2.PHOTO OF RADIO-FREQUENCY, CONTINUOUS RADIATED DISTURBANCE ................................................. 20
7.3.PHOTO OF ELECTROSTATIC DISCHARGE TEST ......................................................................................... 20
8. MANUFACTURER/ APPROVAL HOLDER DECLARATION........................................................21

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 4 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

1. GENERAL INFORMATION
1.1. Product Description for Equipment Under Test (EUT)
EUT

: Bluetooth Headphone

Model No.

: HE09

Frequency Range

: 2402.00-2480.00MHz

Channel Number

: 79 channel for Bluetooth V4.0 (DSS)
40 channels for Bluetooth V4.0 (DTS)

Channel Spacing

: 1MHz for Bluetooth V4.0 (DSS)
2MHz for Bluetooth V4.0 (DTS)

Modulation Type

: GFSK, π/4-DQPSK, 8-DPSK

Bluetooth Version

: V4.0

Antenna Gain

: Integral antenna, 2.0dBi(Max.)

Input Voltage

: DC 3.7V by battery(360mAh)
Recharge Voltage: DC 5V/0.22A

1.2. Objective
ETSI EN 301
489-1

Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro
Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1:
Common technical requirements

ETSI EN 301
489-17

Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic
Compatibility (EMC) standard for radio equipment Part 17: Specific conditions for
Broadband Data Transmission Systems

The objective is to determine EUT compliance with ETSI EN 301 489-1 V1.9.2 (2011-09) and
ETSI EN 301 489-17 V2.2.1 (2012-09).

1.3. Related Submittal(s)/Grant(s)
No Related Submittals.

1.4. Test Methodology
All measurements contained in this report were conducted with ETSI EN 301 489-1 V1.9.2 (2011-09)
and ETSI EN 301 489-17 V2.2.1 (2012-09).

1.5. Facilities
All measurement facilities used to collect the measurement data are located at 1/F., Xingyuan Industrial
Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China.
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR
Publication 22.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 5 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

1.6. Support equipment List
Manufacturer
--

Description
--

Model
--

Serial Number
--

Certificate
--

1.7. External I/O
I/O Port Description

Quantity

Cable

USB Port

1

N/A

1.8. Laboratory Accreditations And Listings
Site Description

EMC Lab.

: Accredited by CNAS, June 04, 2010
The Certificate Registration Number. is L4595.
Accredited by FCC, April 22, 2011
The Certificate Registration Number. is 899208.
Accredited by Industry Canada, May. 02, 2011
The Certificate Registration Number. is 9642A-1

Name of Firm

: Shenzhen LCS Compliance Testing Laboratory Ltd.

Site Location

: 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District,
Shenzhen, Guangdong, China

1.9. Measurement Uncertainty
Item
Uncertainty for Power point Conducted Emissions Test
Uncertainty for Radiation Emission test in 3m chamber
(30MHz to 1GHz)
Uncertainty for Radiation Emission test in 3m chamber
(1GHz to 25GHz)

MU
2.42dB
3.54dB
4.10dB
2.08dB
2.56dB

Remark
Polarize: V
Polarize: H
Polarize: H
Polarize: V

1.10. Description Of Test Modes
MODE 1:
Normal Operating (Bluetooth is active)

MODE 2:
Idle
***Note: All test modes were tested, but we only recorded the worst case in this report.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 6 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

2. SUMMARY OF TEST RESULTS
Rule
§7.1
§7.1
§7.1
§7.1
§7.1
§7.1
§7.2
§7.2
§7.2
§7.2
§7.2
§7.2
§7.2

Description of Test

Reference to clauses EN 301 489-1
§8.4 AC mains power input/output ports
Reference to clauses EN 301 489-1§8.3 DC power input/output
ports
Reference to clauses EN 301 489-1
§8.2 Enclosure of ancillary equipment measured on a stand
alone basis
Reference to clauses EN 301 489-1
§8.5 Harmonic current emissions (AC mains input port)
Reference to clauses EN 301 489-1
§8.6 Voltage fluctuations and flicker (AC mains input port)
Reference to clauses EN 301 489-1§8.7 Telecommunication ports
Reference to clauses EN 301 489-1 §9.3 Electrostatic discharge
(EN 61000-4-2)
Reference to clauses EN 301 489-1
§9.2 Radio frequency electromagnetic field (80 MHz to
1 000 MHz and 1 400 MHz to 2 000 MHz)(EN 61000-4-3)
Reference to clauses EN 301 489-1§9.4 Fast transients, common
mode (EN 61000-4-4)
Reference to clauses EN 301 489-1§9.8 Surges
(EN 61000-4-5)
Reference to clauses EN 301 489-1§9.5 Radio frequency, common
mode (EN 61000-4-6)
Reference to clauses EN 301 489-1
§9.6 Transients and surges in the vehicular environment
(ISO 7637-2)
Reference to clauses EN 301 489-1§9.7 Voltage dips and
interruptions (EN 61000-4-11)

Result

N/A
N/A*
Compliant
N/A
N/A
N/A*
Compliant
Compliant
N/A
N/A
N/A
N/A*
N/A

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 7 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

3. RADIATED DISTURBANCE
3.1. Radiated Emission Limit
ETSI 301 489-1 V1.9.2 (2011-09)/EN 55022 Class B

Limits for radiated disturbance Blow 1GHz
FREQUENCY
(MHz)
30 ~ 230
230 ~ 1000

DISTANCE
(Meters)
3

FIELD STRENGTHS LIMIT
(dBμV/m)
40

3

47

Note: (1) The smaller limit shall apply at the combination point between two frequency bands. (2)
Distance refers to the distance in meters between the measuring instrument antenna and the
closed point of any part of the EUT.

Limits for radiated disturbance Above 1GHz
FREQUENCY
(MHz)
1000-3000

DISTANCE
(Meters)
3

Average Limit
(dBμV/m)
50

3000-6000

3

54

Peak Limit
(dBμV/m)
70
74

Note: The lower limit applies at the transition frequency.

3.2. Test Equipment
Item
1
2

Manufacturer
ROHDE & SCHWARZ
ROHDE & SCHWARZ

Model No.
ESCI
ESPI

SIDT FRANKONIA

SAC-3M

4
5

Test Equipment
EMI Test Receiver
EMI Test Receiver
3m Semi Anechoic
Chamber
Amplifier
Amplifier

6

Amplifier

MITEQ

7

Spectrum Analyzer

Agilent

8

Signal analyzer

Agilent

9
10
11

Loop Antenna
By-log Antenna
Horn Antenna

R&S
SCHWARZBECK
EMCO

12

Horn Antenna

SCHWARZBECK

13

RF Cable-R03m

Jye Bao

14

RF Cable-HIGH

SUHNER

3

SCHAFFNER
Agilent

Serial No.
101142
101840

Last Cal.
2013-06-18
2013-06-18

Due Cal.
2014-06-17
2014-06-17

03CH03-HY 2013-06-18

2014-06-17

COA9231A
18667
2013-06-18
8449B
3008A02120 2013-06-16
AMF-6F-260
9121372 2013-06-16
400
MY4144029
E4407B
2013-06-16
2
E4448A(Exte
rnal mixers to US44300469 2013-06-16
40GHz)
HFH2-Z2 860004/001 2013-06-18
VULB9163 9163-470 2013-06-10
3115
6741
2013-06-10
BBHA91701
2013-06-10
BBHA9170
54
RG142
CB021
2013-06-18
SUCOFLEX
03CH03-HY 2013-06-18
106

2014-06-17
2014-06-15
2014-06-15
2014-06-15
2014-06-15
2014-06-17
2014-06-09
2014-06-09
2014-06-09
2014-06-17
2014-06-17

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 8 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

3.3. Test Configuration

Antenna
tower

Horn
antenna

3m
EUT
4m

Spectrum
analyzer
Turntable

0.8m

1m
Pre-amp

Above 1000MHz

3.4. Test Procedure
Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement
methods.

3.5. Test Data
The worst test mode of the EUT was Mode 1, and its test data was showed as the follow:

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 9 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 10 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

Test Mode: Mode 1(above 1GHz)

Tested by: Andy

Test voltage: DC 3.7V by battery

Test Distance: 3m

Detector Function: Peak+AV

Test Results: Passed

Polarization

Horizontal

Vertical

Frequency
MHz
1402.53
1855.24
3217.61
3963.19
4449.68
4864.23
1383.15
1875.30
3226.21
3734.08
4446.38
4855.59

Emission Level
dBμV/m
55.45
54.60
56.41
60.47
61.89
63.35
53.91
58.07
58.05
61.75
59.93
63.49

37.66
35.12
32.92
36.93
39.48
37.58
34.40
34.88
37.51
36.59
38.14
36.47

Limits
dBμV/m
70.00
70.00
74.00
74.00
74.00
74.00
70.00
70.00
74.00
74.00
74.00
74.00

50.00
50.00
54.00
54.00
54.00
54.00
50.00
50.00
54.00
54.00
54.00
54.00

Margin
dBμV/m
-14.55
-15.40
-17.59
-13.53
-12.11
-10.65
-16.09
-11.93
-15.95
-12.25
-14.07
-10.51

-12.34
-14.88
-21.08
-17.07
-14.52
-16.42
-15.60
-15.12
-16.49
-17.41
-15.86
-17.53

1. Field strength limits for frequency above 1000MHz are based on average limits. However,
Peak mode field strength shall not exceed the average limits specified plus 20dB.
2. Measurements above show only up to 6 maximum emissions noted.
3. Data of measurement within this frequency range shown “ -- ” in the table above means the
reading of emissions are attenuated more than 20dB below the permissible limits or the field
strength is too small to be measured.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 11 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

4. GENERAL PERFORMANCE CRITERIA FOR IMMUNITY TEST
4.1. Performance criteria for Continuous phenomena applied to Transmitter (CT)
For equipment of type II or type III that requires a communication link that is maintained during the test, it
shall be verified by appropriate means supplied by the manufacturer that the communication link is
maintained during each individual exposure in the test sequence.
Where the EUT is a transmitter, tests shall be repeated with the EUT in standby mode to ensure that any
unintentional transmission does not occur.

4.2. Performance criteria for Transient phenomena applied to Transmitter (TT)
For equipment of type II or type III that requires a communication link that is maintained during the test,
this shall be verified by appropriate means supplied by the manufacturer during each individual exposure in
the test sequence. Where the EUT is a transmitter, tests shall be repeated with the EUT in standby mode to
ensure that any unintentional transmission does not occur.

4.3. Performance criteria for Continuous phenomena applied to Receiver (CR)
For equipment of type II or III that requires a communication link that is maintained during the test, it shall
be verified by appropriate means supplied by the manufacturer that the communication link is maintained
during each individual exposure in the test sequence. Where the EUT is a transceiver, under no
circumstances shall the transmitter operate unintentionally during the test.

4.4. Performance criteria for Transient phenomena applied to Receiver (TR)
For equipment of type II or type III that requires a communication link that is maintained during the test,
this shall be verified by appropriate means supplied by the manufacturer during each individual exposure in
the test sequence. Where the EUT is a transceiver, under no circumstances shall the transmitter operate
unintentionally during the test.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 12 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

5. ETSI EN 301 489-17 V2.2.1 §7.2 – RF ELECTROMAGNETIC FIELD (80 MHz
-1000 MHz and 1400 MHz –2700 MHz)
Please refer to ETSI EN 301 489-1, ETSI EN 301 489-17 and EN 61000-4-3.

5.1. Test Equipment
Item
Test Equipment
Manufacturer
1
Signal Generator
R&S
2
Amplifier
AR
3
Amplifier
AR
4 Isotropic Field Monitor
AR
5
Isotropic Field Probe
AR
6
Bi-conic Antenna
EMCO
7 By-log-periodic Antenna
AR
ROHDE &
8
EMS Test Software
SCHWARZ

Model No.
SMR40
500A100
100W/1000M1
FM2000
FP2000
3108
AT1080

Serial No.
10016
17034
17028
16829
16755
9507-2534
16812

Last Cal.
2013-06-16
2013-06-18
2013-06-18
2013-06-18
2013-06-18
2013-06-18
2013-06-18

Due Cal.
2014-06-15
2014-06-17
2014-06-17
2014-06-17
2014-06-17
2014-06-17
2014-06-17

ESK1

N/A

2013-06-18

2014-06-17

5.2. Test Configuration

3 meter

9x6x6
EUT & Support
Units

1.5 meter
0.8m

Power Amp

PC Controller to
control S.G. & PA as
well as forward
power

Signal
Generator

EUT Monitoring by
using a camera

Control Room

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 13 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

5.3. Test Standard
ETSI 301 489-1 V1.9.2 (2011-09)/ (EN 61000-4-3: 2006+A1: 2008+A2: 2010)
Test level 2 at 3V / m
Test Level
Level

Field Strength V/m

1.

1

2.

3

3.

10

X

Special

Performance criterion: A

5.4. Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. EUT is set 3
meter away from the transmitting antenna which is mounted on an antenna tower. Both horizontal
and vertical polarization of the antenna are set on test. Each of the four sides of EUT must be faced
this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD
camera is used to monitor EUT screen. All the scanning conditions are as follows:
Condition of Test
---------------------------------------------1. Fielded Strength
2. Radiated Signal
3. Scanning Frequency
4. Dwell time of radiated
5. Waiting Time

Remarks
---------------------------------3 V/m (Severity Level 2)
Unmodulated
80 – 1000 1400-2700MHz
0.0015 decade/s
3 Sec.

5.5. Test Data
PASS.
Please refer to the following page.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 14 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

RF Field Strength Susceptibility Test Results
Standard

† IEC 61000-4-3

; EN 61000-4-3

Applicant

Dongguan Juling Electronics Technology Co., Ltd.

EUT

Bluetooth Headphone

Temperature

24℃

M/N

HE09

Humidity

53%

Field Strength

3V/m

Criterion

A

Test Mode

Mode 1

Test Engineer

Andy

Frequency
Range

80-1000MHz, 1.4GHz-2.7GHz,

Test Date

January 18, 2013

Modulation

†None

Steps

1%

† Pulse

Field

Modulation

Polarity

3V/m

Yes

H/V

3V/m

Yes

H/V

3V/m

Yes

H/V

3V/m

Yes

H/V

;AM 1KHz 80%

Position
Right, Left, Front,
Back
Right, Left, Front,
Back
Right, Left, Front,
Back
Right, Left, Front,
Back

Observation

Result

CT, CR

PASS

CT, CR

PASS

CT, CR

PASS

CT, CR

PASS

Note:
During the test, the communication link is maintained. Unintentional transmission is not founded from the EUT.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 15 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

6. ELECTROSTATIC DISCHARGE
Please refer to ETSI EN 301 489-1 and EN 61000-4-2.

6.1. Test Equipment
Item Test Equipment Manufacturer
1 ESD Simulator
KIKUSUI

Model No.
KC001311

Serial No.
KES4021

Last Cal.
2013-06-18

Due Cal.
2014-06-17

6.2. Test Configuration

10 cm

0.5 mm Thick
Insulator

EUT

0.8 m

HCP

VCP

470 k
Ω

470 kΩ

Ground

EN 61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80
centimeters above a ground reference plane and that floor mounted equipment shall be placed on a
insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is
positioned over a ground reference plane in conformance with this requirement.
For tabletop equipment, a 1.5 by 1.0-meter metal sheet (HCP) is placed on the table and connected
to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached
cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical
Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP
is used.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 16 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

6.3. Test Procedure
ETSI 301 489-1 V1.9.2 (2011-09)/ EN 61000-4-2: 2009
Test level 3 for Air Discharge at ±8 kV
Test level 2 for Contact Discharge at ±4 kV
6.3.1. Air Discharge
This test is done on a non-conductive surface. The round discharge tip of the discharge electrode
shall be approached as fast as possible to touch the EUT. After each discharge, the discharge
electrode shall be removed from the EUT. The generator is then re-triggered for a new single
discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated
until all the air discharge completed.
6.3.2. Contact Discharge
All the procedure shall be same as Section 6.3.1. except that the tip of the discharge electrode shall
touch the EUT before the discharge switch is operated.
6.3.3. Indirect Discharge For Horizontal Coupling Plane
At least 10 single discharges (in the most sensitive polarity) shall be applied at the front edge of each
HCP opposite the center point of each unit (if applicable) of the EUT and 0.1m from the front of the
EUT. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to
its front edge during the discharge.
6.3.4. Indirect Discharge For Vertical Coupling Plane
At least 10 single discharges (in the most sensitive polarity) shall be applied to the center of one
vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed
parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the
coupling plane, with this plane in sufficient different positions that the four faces of the EUT are
completely illuminated.

6.4. Test Data
PASS.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 17 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

Electrostatic Discharge Test Results
Standard

† IEC 61000-4-2

; EN 61000-4-2

Applicant

Dongguan Juling Electronics Technology Co., Ltd.

EUT

Bluetooth Headphone

Temperature

24℃

M/N

HE09

Humidity

54%

Criterion

B

Pressure

1021mbar

Test Mode

Mode 1

Test Date

January 18, 2013

Test Engineer

Andy
Test Result Of Mode 1

Test Voltage

Coupling

Observation

Result (Pass/Fail)

±2KV, ±4kV

Contact Discharge

TT, TR

Pass

±2KV, ±4kV, ±8kV

Air Discharge

TT, TR

Pass

±2KV, ±4kV

Indirect Discharge HCP

TT, TR

Pass

±2KV, ±4kV

Indirect Discharge VCP

TT, TR

Pass

Note:

During the test, the communication link is maintained. Unintentional transmission is not founded from
the EUT.

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 18 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

7. TEST SETUP PHOTOGRAPHS
7.1.Photo of Radiated Measurement

Below 1G

Above 1G

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 19 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

7.2.Photo of Radio-frequency, Continuous radiated disturbance

7.3.Photo of Electrostatic Discharge Test

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 20 of 21

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.

Report No.: LCS140114249TE

8. MANUFACTURER/ APPROVAL HOLDER DECLARATION
The following identical model(s):
HE01

HE02

HE03

HE04

HE05

HE08

HE09

HE14

HE16

--

--

--

Belong to the tested device:
Product description

: Bluetooth Headphone

Model name

: HE09

Remark: PCB board, structure and internal of these model(s) are the same,
So no additional models were tested.

---------------THE END OF REPORT-------------

This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
Page 21 of 21



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2014:01:22 17:28:58+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2014:01:24 09:54:11+08:00
Metadata Date                   : 2014:01:24 09:54:11+08:00
Format                          : application/pdf
Title                           : Microsoft Word - LCS140114249TE.doc
Creator                         : Administrator
Document ID                     : uuid:61d97cd5-16ba-453d-bdda-5ea895b86f01
Instance ID                     : uuid:ec4b8d26-8fc8-4f2f-b310-c42614305ffc
Page Count                      : 21
Author                          : Administrator
EXIF Metadata provided by EXIF.tools

Navigation menu