LCS140114249TE
Lcs140114249Te LCS140114249TE LCS140114249TE CertsReports 178747 ProductFiles assets.mhint
Lcs140114249Te LCS140114249TE LCS140114249TE CertsReports 178754 ProductFiles assets.mhint
2016-04-06
: Pdf Lcs140114249Te LCS140114249TE CertsReports 178761 ProductFiles
Open the PDF directly: View PDF .
Page Count: 21
Download | |
Open PDF In Browser | View PDF |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE EMC TEST REPORT For Dongguan Juling Electronics Technology Co., Ltd. Bluetooth Headphone Model No.: HE09 Additional Model No.: HE01, HE02, HE03, HE04, HE05, HE08, HE14, HE16 Prepared for Address : Dongguan Juling Electronics Technology Co., Ltd. : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China Prepared by Address : Shenzhen LCS Compliance Testing Laboratory Ltd. : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Date of receipt of test sample Number of tested samples Serial number Date of Test Date of Report : : : : : January 14, 2014 1 Prototype January 14, 2014 - January 22, 2014 January 22, 2014 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE EMC TEST REPORT ETSI EN 301 489-17 V2.2.1 (2012-09) Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC)standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems Report Reference No.................. : LCS140114249TE Date of Issue................................. : January 22, 2014 Testing Laboratory Name.......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address......................................... Testing Location/ Procedure......... 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Full application of Harmonised standards ■ : Partial application of Harmonised standards □ Other standard testing method □ : Applicant’s Name ....................... : Dongguan Juling Electronics Technology Co., Ltd. Address......................................... : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China Test Specification Test Report Form No. ................. ETSI EN 301 489-1 V1.9.2 (2011-09) ETSI EN 301 489-17 V2.2.1 (2012-09) : LCSEMC-1.0 TRF Originator............................. : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................. : Dated 2011-03 Standard........................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description ............... : Bluetooth Headphone Trade Mark ................................... : N/A Model/ Type reference ................. : HE09 Ratings.......................................... : Result ………………………...... : Positive DC 3.7V by battery(360mAh) Recharge Voltage: DC 5V/0.22A Compiled by: Supervised by: Approved by: Tree Zhan/ File administrators Fox Zhang/ Technique principal Gavin Liang/ Manager This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE EMC -- TEST REPORT Test Report No. : LCS140114249TE January 22, 2014 Date of issue Type / Model........................... : HE09 EUT......................................... : Bluetooth Headphone Applicant............................... : Dongguan Juling Electronics Technology Co., Ltd. Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Dongguan Juling Electronics Technology Co., Ltd. Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China Telephone............................... : / Fax.......................................... : / Factory................................... : Dongguan Juling Electronics Technology Co., Ltd. Address.................................. : Jiuwei Industrial Zone, Qishi Town, Dongguan City, Guangdong, China Telephone............................... : / Fax.......................................... : / Test Result: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE TABLE OF CONTENTS 1. GENERAL INFORMATION ..................................................................................................................5 1.1. PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................. 5 1.2. OBJECTIVE ................................................................................................................................................ 5 1.3. RELATED SUBMITTAL(S)/GRANT(S) ......................................................................................................... 5 1.4. TEST METHODOLOGY ............................................................................................................................... 5 1.5. FACILITIES ................................................................................................................................................ 5 1.6. SUPPORT EQUIPMENT LIST ........................................................................................................................ 6 1.7. EXTERNAL I/O.......................................................................................................................................... 6 1.8. LABORATORY ACCREDITATIONS AND LISTINGS....................................................................................... 6 1.9. MEASUREMENT UNCERTAINTY ................................................................................................................ 6 1.10. DESCRIPTION OF TEST MODES ............................................................................................................... 6 2. SUMMARY OF TEST RESULTS...........................................................................................................7 3. RADIATED DISTURBANCE.................................................................................................................8 3.1. RADIATED EMISSION LIMIT ...................................................................................................................... 8 3.2. TEST EQUIPMENT...................................................................................................................................... 8 3.3. TEST CONFIGURATION .............................................................................................................................. 9 3.4. TEST PROCEDURE ..................................................................................................................................... 9 3.5. TEST DATA ............................................................................................................................................... 9 4. GENERAL PERFORMANCE CRITERIA FOR IMMUNITY TEST ..............................................12 4.1. PERFORMANCE CRITERIA FOR CONTINUOUS PHENOMENA APPLIED TO TRANSMITTER (CT) ................... 12 4.2. PERFORMANCE CRITERIA FOR TRANSIENT PHENOMENA APPLIED TO TRANSMITTER (TT)....................... 12 4.3. PERFORMANCE CRITERIA FOR CONTINUOUS PHENOMENA APPLIED TO RECEIVER (CR).......................... 12 4.4. PERFORMANCE CRITERIA FOR TRANSIENT PHENOMENA APPLIED TO RECEIVER (TR) ............................. 12 5. ETSI EN 301 489-17 V2.2.1 §7.2 – RF ELECTROMAGNETIC FIELD (80 MHz -1000 MHz and 1400 MHz –2700 MHz) .......................................................................................................................................13 5.1. TEST EQUIPMENT.................................................................................................................................... 13 5.2. TEST CONFIGURATION ............................................................................................................................ 13 5.3. TEST STANDARD ..................................................................................................................................... 14 5.4. TEST PROCEDURE ................................................................................................................................... 14 5.5. TEST DATA ............................................................................................................................................. 14 6. ELECTROSTATIC DISCHARGE .......................................................................................................16 6.1. TEST EQUIPMENT.................................................................................................................................... 16 6.2. TEST CONFIGURATION ............................................................................................................................ 16 6.3. TEST PROCEDURE ................................................................................................................................... 17 6.4. TEST DATA ............................................................................................................................................. 17 7. TEST SETUP PHOTOGRAPHS ..........................................................................................................19 7.1.PHOTO OF RADIATED MEASUREMENT ..................................................................................................... 19 7.2.PHOTO OF RADIO-FREQUENCY, CONTINUOUS RADIATED DISTURBANCE ................................................. 20 7.3.PHOTO OF ELECTROSTATIC DISCHARGE TEST ......................................................................................... 20 8. MANUFACTURER/ APPROVAL HOLDER DECLARATION........................................................21 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 1. GENERAL INFORMATION 1.1. Product Description for Equipment Under Test (EUT) EUT : Bluetooth Headphone Model No. : HE09 Frequency Range : 2402.00-2480.00MHz Channel Number : 79 channel for Bluetooth V4.0 (DSS) 40 channels for Bluetooth V4.0 (DTS) Channel Spacing : 1MHz for Bluetooth V4.0 (DSS) 2MHz for Bluetooth V4.0 (DTS) Modulation Type : GFSK, π/4-DQPSK, 8-DPSK Bluetooth Version : V4.0 Antenna Gain : Integral antenna, 2.0dBi(Max.) Input Voltage : DC 3.7V by battery(360mAh) Recharge Voltage: DC 5V/0.22A 1.2. Objective ETSI EN 301 489-1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro Magnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements ETSI EN 301 489-17 Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment Part 17: Specific conditions for Broadband Data Transmission Systems The objective is to determine EUT compliance with ETSI EN 301 489-1 V1.9.2 (2011-09) and ETSI EN 301 489-17 V2.2.1 (2012-09). 1.3. Related Submittal(s)/Grant(s) No Related Submittals. 1.4. Test Methodology All measurements contained in this report were conducted with ETSI EN 301 489-1 V1.9.2 (2011-09) and ETSI EN 301 489-17 V2.2.1 (2012-09). 1.5. Facilities All measurement facilities used to collect the measurement data are located at 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 1.6. Support equipment List Manufacturer -- Description -- Model -- Serial Number -- Certificate -- 1.7. External I/O I/O Port Description Quantity Cable USB Port 1 N/A 1.8. Laboratory Accreditations And Listings Site Description EMC Lab. : Accredited by CNAS, June 04, 2010 The Certificate Registration Number. is L4595. Accredited by FCC, April 22, 2011 The Certificate Registration Number. is 899208. Accredited by Industry Canada, May. 02, 2011 The Certificate Registration Number. is 9642A-1 Name of Firm : Shenzhen LCS Compliance Testing Laboratory Ltd. Site Location : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China 1.9. Measurement Uncertainty Item Uncertainty for Power point Conducted Emissions Test Uncertainty for Radiation Emission test in 3m chamber (30MHz to 1GHz) Uncertainty for Radiation Emission test in 3m chamber (1GHz to 25GHz) MU 2.42dB 3.54dB 4.10dB 2.08dB 2.56dB Remark Polarize: V Polarize: H Polarize: H Polarize: V 1.10. Description Of Test Modes MODE 1: Normal Operating (Bluetooth is active) MODE 2: Idle ***Note: All test modes were tested, but we only recorded the worst case in this report. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 6 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 2. SUMMARY OF TEST RESULTS Rule §7.1 §7.1 §7.1 §7.1 §7.1 §7.1 §7.2 §7.2 §7.2 §7.2 §7.2 §7.2 §7.2 Description of Test Reference to clauses EN 301 489-1 §8.4 AC mains power input/output ports Reference to clauses EN 301 489-1§8.3 DC power input/output ports Reference to clauses EN 301 489-1 §8.2 Enclosure of ancillary equipment measured on a stand alone basis Reference to clauses EN 301 489-1 §8.5 Harmonic current emissions (AC mains input port) Reference to clauses EN 301 489-1 §8.6 Voltage fluctuations and flicker (AC mains input port) Reference to clauses EN 301 489-1§8.7 Telecommunication ports Reference to clauses EN 301 489-1 §9.3 Electrostatic discharge (EN 61000-4-2) Reference to clauses EN 301 489-1 §9.2 Radio frequency electromagnetic field (80 MHz to 1 000 MHz and 1 400 MHz to 2 000 MHz)(EN 61000-4-3) Reference to clauses EN 301 489-1§9.4 Fast transients, common mode (EN 61000-4-4) Reference to clauses EN 301 489-1§9.8 Surges (EN 61000-4-5) Reference to clauses EN 301 489-1§9.5 Radio frequency, common mode (EN 61000-4-6) Reference to clauses EN 301 489-1 §9.6 Transients and surges in the vehicular environment (ISO 7637-2) Reference to clauses EN 301 489-1§9.7 Voltage dips and interruptions (EN 61000-4-11) Result N/A N/A* Compliant N/A N/A N/A* Compliant Compliant N/A N/A N/A N/A* N/A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 7 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 3. RADIATED DISTURBANCE 3.1. Radiated Emission Limit ETSI 301 489-1 V1.9.2 (2011-09)/EN 55022 Class B Limits for radiated disturbance Blow 1GHz FREQUENCY (MHz) 30 ~ 230 230 ~ 1000 DISTANCE (Meters) 3 FIELD STRENGTHS LIMIT (dBμV/m) 40 3 47 Note: (1) The smaller limit shall apply at the combination point between two frequency bands. (2) Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the EUT. Limits for radiated disturbance Above 1GHz FREQUENCY (MHz) 1000-3000 DISTANCE (Meters) 3 Average Limit (dBμV/m) 50 3000-6000 3 54 Peak Limit (dBμV/m) 70 74 Note: The lower limit applies at the transition frequency. 3.2. Test Equipment Item 1 2 Manufacturer ROHDE & SCHWARZ ROHDE & SCHWARZ Model No. ESCI ESPI SIDT FRANKONIA SAC-3M 4 5 Test Equipment EMI Test Receiver EMI Test Receiver 3m Semi Anechoic Chamber Amplifier Amplifier 6 Amplifier MITEQ 7 Spectrum Analyzer Agilent 8 Signal analyzer Agilent 9 10 11 Loop Antenna By-log Antenna Horn Antenna R&S SCHWARZBECK EMCO 12 Horn Antenna SCHWARZBECK 13 RF Cable-R03m Jye Bao 14 RF Cable-HIGH SUHNER 3 SCHAFFNER Agilent Serial No. 101142 101840 Last Cal. 2013-06-18 2013-06-18 Due Cal. 2014-06-17 2014-06-17 03CH03-HY 2013-06-18 2014-06-17 COA9231A 18667 2013-06-18 8449B 3008A02120 2013-06-16 AMF-6F-260 9121372 2013-06-16 400 MY4144029 E4407B 2013-06-16 2 E4448A(Exte rnal mixers to US44300469 2013-06-16 40GHz) HFH2-Z2 860004/001 2013-06-18 VULB9163 9163-470 2013-06-10 3115 6741 2013-06-10 BBHA91701 2013-06-10 BBHA9170 54 RG142 CB021 2013-06-18 SUCOFLEX 03CH03-HY 2013-06-18 106 2014-06-17 2014-06-15 2014-06-15 2014-06-15 2014-06-15 2014-06-17 2014-06-09 2014-06-09 2014-06-09 2014-06-17 2014-06-17 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 8 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 3.3. Test Configuration Antenna tower Horn antenna 3m EUT 4m Spectrum analyzer Turntable 0.8m 1m Pre-amp Above 1000MHz 3.4. Test Procedure Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement methods. 3.5. Test Data The worst test mode of the EUT was Mode 1, and its test data was showed as the follow: This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 9 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 10 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE Test Mode: Mode 1(above 1GHz) Tested by: Andy Test voltage: DC 3.7V by battery Test Distance: 3m Detector Function: Peak+AV Test Results: Passed Polarization Horizontal Vertical Frequency MHz 1402.53 1855.24 3217.61 3963.19 4449.68 4864.23 1383.15 1875.30 3226.21 3734.08 4446.38 4855.59 Emission Level dBμV/m 55.45 54.60 56.41 60.47 61.89 63.35 53.91 58.07 58.05 61.75 59.93 63.49 37.66 35.12 32.92 36.93 39.48 37.58 34.40 34.88 37.51 36.59 38.14 36.47 Limits dBμV/m 70.00 70.00 74.00 74.00 74.00 74.00 70.00 70.00 74.00 74.00 74.00 74.00 50.00 50.00 54.00 54.00 54.00 54.00 50.00 50.00 54.00 54.00 54.00 54.00 Margin dBμV/m -14.55 -15.40 -17.59 -13.53 -12.11 -10.65 -16.09 -11.93 -15.95 -12.25 -14.07 -10.51 -12.34 -14.88 -21.08 -17.07 -14.52 -16.42 -15.60 -15.12 -16.49 -17.41 -15.86 -17.53 1. Field strength limits for frequency above 1000MHz are based on average limits. However, Peak mode field strength shall not exceed the average limits specified plus 20dB. 2. Measurements above show only up to 6 maximum emissions noted. 3. Data of measurement within this frequency range shown “ -- ” in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 11 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 4. GENERAL PERFORMANCE CRITERIA FOR IMMUNITY TEST 4.1. Performance criteria for Continuous phenomena applied to Transmitter (CT) For equipment of type II or type III that requires a communication link that is maintained during the test, it shall be verified by appropriate means supplied by the manufacturer that the communication link is maintained during each individual exposure in the test sequence. Where the EUT is a transmitter, tests shall be repeated with the EUT in standby mode to ensure that any unintentional transmission does not occur. 4.2. Performance criteria for Transient phenomena applied to Transmitter (TT) For equipment of type II or type III that requires a communication link that is maintained during the test, this shall be verified by appropriate means supplied by the manufacturer during each individual exposure in the test sequence. Where the EUT is a transmitter, tests shall be repeated with the EUT in standby mode to ensure that any unintentional transmission does not occur. 4.3. Performance criteria for Continuous phenomena applied to Receiver (CR) For equipment of type II or III that requires a communication link that is maintained during the test, it shall be verified by appropriate means supplied by the manufacturer that the communication link is maintained during each individual exposure in the test sequence. Where the EUT is a transceiver, under no circumstances shall the transmitter operate unintentionally during the test. 4.4. Performance criteria for Transient phenomena applied to Receiver (TR) For equipment of type II or type III that requires a communication link that is maintained during the test, this shall be verified by appropriate means supplied by the manufacturer during each individual exposure in the test sequence. Where the EUT is a transceiver, under no circumstances shall the transmitter operate unintentionally during the test. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 12 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 5. ETSI EN 301 489-17 V2.2.1 §7.2 – RF ELECTROMAGNETIC FIELD (80 MHz -1000 MHz and 1400 MHz –2700 MHz) Please refer to ETSI EN 301 489-1, ETSI EN 301 489-17 and EN 61000-4-3. 5.1. Test Equipment Item Test Equipment Manufacturer 1 Signal Generator R&S 2 Amplifier AR 3 Amplifier AR 4 Isotropic Field Monitor AR 5 Isotropic Field Probe AR 6 Bi-conic Antenna EMCO 7 By-log-periodic Antenna AR ROHDE & 8 EMS Test Software SCHWARZ Model No. SMR40 500A100 100W/1000M1 FM2000 FP2000 3108 AT1080 Serial No. 10016 17034 17028 16829 16755 9507-2534 16812 Last Cal. 2013-06-16 2013-06-18 2013-06-18 2013-06-18 2013-06-18 2013-06-18 2013-06-18 Due Cal. 2014-06-15 2014-06-17 2014-06-17 2014-06-17 2014-06-17 2014-06-17 2014-06-17 ESK1 N/A 2013-06-18 2014-06-17 5.2. Test Configuration 3 meter 9x6x6 EUT & Support Units 1.5 meter 0.8m Power Amp PC Controller to control S.G. & PA as well as forward power Signal Generator EUT Monitoring by using a camera Control Room This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 13 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 5.3. Test Standard ETSI 301 489-1 V1.9.2 (2011-09)/ (EN 61000-4-3: 2006+A1: 2008+A2: 2010) Test level 2 at 3V / m Test Level Level Field Strength V/m 1. 1 2. 3 3. 10 X Special Performance criterion: A 5.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. EUT is set 3 meter away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor EUT screen. All the scanning conditions are as follows: Condition of Test ---------------------------------------------1. Fielded Strength 2. Radiated Signal 3. Scanning Frequency 4. Dwell time of radiated 5. Waiting Time Remarks ---------------------------------3 V/m (Severity Level 2) Unmodulated 80 – 1000 1400-2700MHz 0.0015 decade/s 3 Sec. 5.5. Test Data PASS. Please refer to the following page. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 14 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE RF Field Strength Susceptibility Test Results Standard IEC 61000-4-3 ; EN 61000-4-3 Applicant Dongguan Juling Electronics Technology Co., Ltd. EUT Bluetooth Headphone Temperature 24℃ M/N HE09 Humidity 53% Field Strength 3V/m Criterion A Test Mode Mode 1 Test Engineer Andy Frequency Range 80-1000MHz, 1.4GHz-2.7GHz, Test Date January 18, 2013 Modulation None Steps 1% Pulse Field Modulation Polarity 3V/m Yes H/V 3V/m Yes H/V 3V/m Yes H/V 3V/m Yes H/V ;AM 1KHz 80% Position Right, Left, Front, Back Right, Left, Front, Back Right, Left, Front, Back Right, Left, Front, Back Observation Result CT, CR PASS CT, CR PASS CT, CR PASS CT, CR PASS Note: During the test, the communication link is maintained. Unintentional transmission is not founded from the EUT. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 15 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 6. ELECTROSTATIC DISCHARGE Please refer to ETSI EN 301 489-1 and EN 61000-4-2. 6.1. Test Equipment Item Test Equipment Manufacturer 1 ESD Simulator KIKUSUI Model No. KC001311 Serial No. KES4021 Last Cal. 2013-06-18 Due Cal. 2014-06-17 6.2. Test Configuration 10 cm 0.5 mm Thick Insulator EUT 0.8 m HCP VCP 470 k Ω 470 kΩ Ground EN 61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement. For tabletop equipment, a 1.5 by 1.0-meter metal sheet (HCP) is placed on the table and connected to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP is used. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 16 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 6.3. Test Procedure ETSI 301 489-1 V1.9.2 (2011-09)/ EN 61000-4-2: 2009 Test level 3 for Air Discharge at ±8 kV Test level 2 for Contact Discharge at ±4 kV 6.3.1. Air Discharge This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. 6.3.2. Contact Discharge All the procedure shall be same as Section 6.3.1. except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. 6.3.3. Indirect Discharge For Horizontal Coupling Plane At least 10 single discharges (in the most sensitive polarity) shall be applied at the front edge of each HCP opposite the center point of each unit (if applicable) of the EUT and 0.1m from the front of the EUT. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to its front edge during the discharge. 6.3.4. Indirect Discharge For Vertical Coupling Plane At least 10 single discharges (in the most sensitive polarity) shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated. 6.4. Test Data PASS. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 17 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE Electrostatic Discharge Test Results Standard IEC 61000-4-2 ; EN 61000-4-2 Applicant Dongguan Juling Electronics Technology Co., Ltd. EUT Bluetooth Headphone Temperature 24℃ M/N HE09 Humidity 54% Criterion B Pressure 1021mbar Test Mode Mode 1 Test Date January 18, 2013 Test Engineer Andy Test Result Of Mode 1 Test Voltage Coupling Observation Result (Pass/Fail) ±2KV, ±4kV Contact Discharge TT, TR Pass ±2KV, ±4kV, ±8kV Air Discharge TT, TR Pass ±2KV, ±4kV Indirect Discharge HCP TT, TR Pass ±2KV, ±4kV Indirect Discharge VCP TT, TR Pass Note: During the test, the communication link is maintained. Unintentional transmission is not founded from the EUT. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 18 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 7. TEST SETUP PHOTOGRAPHS 7.1.Photo of Radiated Measurement Below 1G Above 1G This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 19 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 7.2.Photo of Radio-frequency, Continuous radiated disturbance 7.3.Photo of Electrostatic Discharge Test This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 20 of 21 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. Report No.: LCS140114249TE 8. MANUFACTURER/ APPROVAL HOLDER DECLARATION The following identical model(s): HE01 HE02 HE03 HE04 HE05 HE08 HE09 HE14 HE16 -- -- -- Belong to the tested device: Product description : Bluetooth Headphone Model name : HE09 Remark: PCB board, structure and internal of these model(s) are the same, So no additional models were tested. ---------------THE END OF REPORT------------- This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 21 of 21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2014:01:22 17:28:58+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2014:01:24 09:54:11+08:00 Metadata Date : 2014:01:24 09:54:11+08:00 Format : application/pdf Title : Microsoft Word - LCS140114249TE.doc Creator : Administrator Document ID : uuid:61d97cd5-16ba-453d-bdda-5ea895b86f01 Instance ID : uuid:ec4b8d26-8fc8-4f2f-b310-c42614305ffc Page Count : 21 Author : AdministratorEXIF Metadata provided by EXIF.tools