ECOTRONIC

GENERAL DATA
Applications
ECOTRONIC 110, 120 & 130 ECOJET self priming single impeller pump fitted with the Hydrotronic pump control system
ECOTRONIC 230, 240 & 250 ECOPLUS self priming multistage pump (with 2,3 or 4 impellers) fitted with the Hydrotronic pump
control system to supply water for systems including
Pressure Boosting
*
Residential Homes
*
Farming Applications
*
Residential Irrigation
*
Garden Irrigation Drip/Low Flow
*
Hydroponics
*
Rain Water Harvesting
*
Water Supply from Shallow Wells
F version supplied with 5” filter housing and filter cartridge

Constructional features of the pump .

Technopolymer pump body and motor support.
Carbon/ceramic mechanical seal.
Technopolymer impeller, diffuser, venturi and nozzle in ECOJET
Technopolymer impeller, diffuser, self-priming disc in ECOPLUS

Construction of the motor
Induction motor, closed and cooled with external ventilation.
Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and a long life.
Built-in thermal and current overload protection on ECOTRONIC 110 & 230
Bult-in thermal and resettable overload protection on ECOTRONIC 120, 130, 240 & 250
Motor protection: NEMA 3
Insulation class: F

Standard voltage: 115v 60Hz

Page 1

TECHNICAL DATA
MATERIALS

N°

5

PARTS*

MATERIALS

1

PUMP

SEE ECOJET 110, 120 , 130
SEE ECOPLUS 230, 240, 250

2

NON-RETURN VALVE

TECHNOPOLYMER

3

VALVE BODY

TECHNOPOLYMER

4

FLOW SENSOR

TECHNOPOLYMER

5

FLOW SENSOR BODY

TECHNOPOLYMER

6

OR GASKET

NBR

7

OR GASKET

NBR

15

BODY

TECHNOPOLYMER

7
6

4
3
2
1

* In contact with liquid

Operating Range:

ECOTRONIC 110 to 130 From 1 to 21gpm with a head up to 164ft ( 71 psi )
ECOTRONIC 230 to 250 From 1 to 27gpm with a head up to 197ft ( 85 psi )

Liquid quality requirements:

clean, free from solids or abrasive substances,
non viscous, non aggressive, non crystallized, chemically
neutral, close to the characteristics of water

Liquid temperature Range:

From 32°F to 104°F

Maximum suction depth

26 ft

Maximum ambient temp.

104°F

Maximum operating pressure

116 psi

Installation:

fixed or portable in a horizontal position

Special version on request

other voltages and/or frequencies

Page 2

ECOTRONIC 110
D

C

H1

DNA

H

DNM

F

E
B

A

MODEL
ECOTRONIC 110

A

B

C

D

E

15 3/4”

8 3/4”

4 5/8”

9 1/2”

5 3/4”

F

H

H1

DNA

DNM

Weight

/8”

15 1/2”

6 1/2”

1” NPT

1 ” NPT

26.4 lbs

3

ELECTRICAL DATA
MODEL

P1

Voltage
60Hz

Watt

115v

800

ECOTRONIC 110

HYDRAULIC DATA

Hp

In
A

Start
Pressure

MAX
Flow

Max
Head

Max
Pressure

1/2

8.0

23 psi

16 gpm

138 ft

60 psi

ECOTRONIC 120 F
D

C

H1

DNA

H

DNM

F

E
B

A

MODEL
ECOTRONIC 120 F

A

B

C

D

E

22 3/4”

8 3/4”

11 5/8”

9 1/2”

5 3/4”

F

H

H1

DNA

DNM

Weight

/8”

15 1/2”

6 1/2”

1” NPT

1 ” NPT

29.5 lbs

3

ELECTRICAL DATA
MODEL
ECOTRONIC 120 F

P1

Voltage
60Hz

Watt

115v

1000

HYDRAULIC DATA

Hp

In
A

Start
Pressure

MAX
Flow

Max
Head

Max
Pressure

3/4

10.0

23 psi

16 gpm

164 ft

71 psi

* IF version supplied with a 5” fliter housing and sediment filter housing.

Page 3

ECOTRONIC 130
D

C

H1

DNA

H

DNM

F

E
B

A

MODEL
ECOTRONIC 130

A

B

C

D

E

15 3/4”

8 3/4”

4 5/8”

9 1/2”

5 3/4”

F

H

H1

DNA

DNM

Weight

/8”

15 1/2”

6 1/2”

1” NPT

1 ” NPT

27.2 lbs

3

ELECTRICAL DATA
MODEL
ECOTRONIC 130

P1

Voltage
60Hz

Watt

115v

1250

HYDRAULIC DATA

Hp

In
A

Start
Pressure

MAX
Flow

Max
Head

Max
Pressure

1

13.0

23 psi

21 gpm

164 ft

71 psi

Page 4

ECOTRONIC 230
B

A

DNM

H1

DNA

H

C

F
E

D

MODEL
ECOTRONIC 230

A

B

C

D

E

F

H

H1

DNA

DNM

Weight

16 1/8”

9 1/2”

7 1/8”

6 3/4”

8 1/2”

5 5/8”

15 3/8”

5 5/8”

1” NPT

1 ” NPT

26.4 lbs

ELECTRICAL DATA
MODEL

P1

Voltage
60Hz

Watt

115v

800

ECOTRONIC 230

HYDRAULIC DATA

Hp

In
A

Start
Pressure

MAX
Flow

Max
Head

Max
Pressure

1/2

7.5

23 psi

27 gpm

118 ft

51 psi

ECOTRONIC 240 F
B

A
C

H1

DNA

H

DNM

F
E

D

MODEL
ECOTRONIC 240 F

A

B

C

D

E

F

H

H1

DNA

DNM

Weight

24 ”

9 1/2”

15 1/4”

6 3/4”

8 1/2”

5 5/8”

15 3/8”

5 5/8”

1” NPT

1 ” NPT

29.5 lbs

ELECTRICAL DATA
MODEL
ECOTRONIC 240 F

P1

Voltage
60Hz

Watt

115v

1000

HYDRAULIC DATA

Hp

In
A

Start
Pressure

MAX
Flow

Max
Head

Max
Pressure

3/4

10.0

23 psi

27 gpm

157 ft

68 psi

* IF version supplied with a 5” fliter housing and sediment filter housing.

Page 5

ECOTRONIC 250
B

A

DNM

H1

DNA

H

C

F
E

D

MODEL
ECOTRONIC 250

A

B

C

D

E

F

H

H1

DNA

DNM

Weight

18 ”

9 1/2”

9 1/4”

6 3/4”

8 1/2”

5 5/8”

15 3/8”

5 5/8”

1” NPT

1 ” NPT

27.2 lbs

ELECTRICAL DATA
MODEL
ECOTRONIC 250

P1

Voltage
60Hz

Watt

115v

1200

HYDRAULIC DATA

Hp

In
A

Start
Pressure

MAX
Flow

Max
Head

Max
Pressure

1

13.0

23 psi

27 gpm

197 ft

85 psi

Page 6



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Create Date                     : 2015:05:26 10:50:30-04:00
Creator                         : Adobe InDesign CC 2014 (Windows)
Modify Date                     : 2015:12:09 10:22:10-08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Metadata Date                   : 2015:12:09 10:22:10-08:00
Creator Tool                    : Adobe InDesign CC 2014 (Windows)
Instance ID                     : uuid:32df45c0-6102-5d49-bcb7-24f78368efff
Original Document ID            : xmp.did:98B5A8B4AEF5E011A598DA9DB35A2696
Document ID                     : xmp.id:1b060ef8-2964-c648-8baf-01703a767cb1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:e7476f3f-a606-f143-8eaf-61a61507af64
Derived From Document ID        : xmp.did:6f4e1974-256d-8a47-8dcf-f391c738a63b
Derived From Original Document ID: xmp.did:98B5A8B4AEF5E011A598DA9DB35A2696
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Windows)
History Changed                 : /
History When                    : 2015:05:26 10:50:30-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu