Leader Ecotronic Pumps Data Sheet
2015-12-10
: Pdf Leader-Ecotronic-Pumps Data-Sheet Leader-Ecotronic-Pumps_Data-Sheet product s
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
ECOTRONIC GENERAL DATA Applications ECOTRONIC 110, 120 & 130 ECOJET self priming single impeller pump fitted with the Hydrotronic pump control system ECOTRONIC 230, 240 & 250 ECOPLUS self priming multistage pump (with 2,3 or 4 impellers) fitted with the Hydrotronic pump control system to supply water for systems including Pressure Boosting * Residential Homes * Farming Applications * Residential Irrigation * Garden Irrigation Drip/Low Flow * Hydroponics * Rain Water Harvesting * Water Supply from Shallow Wells F version supplied with 5” filter housing and filter cartridge Constructional features of the pump . Technopolymer pump body and motor support. Carbon/ceramic mechanical seal. Technopolymer impeller, diffuser, venturi and nozzle in ECOJET Technopolymer impeller, diffuser, self-priming disc in ECOPLUS Construction of the motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and a long life. Built-in thermal and current overload protection on ECOTRONIC 110 & 230 Bult-in thermal and resettable overload protection on ECOTRONIC 120, 130, 240 & 250 Motor protection: NEMA 3 Insulation class: F Standard voltage: 115v 60Hz Page 1 TECHNICAL DATA MATERIALS N° 5 PARTS* MATERIALS 1 PUMP SEE ECOJET 110, 120 , 130 SEE ECOPLUS 230, 240, 250 2 NON-RETURN VALVE TECHNOPOLYMER 3 VALVE BODY TECHNOPOLYMER 4 FLOW SENSOR TECHNOPOLYMER 5 FLOW SENSOR BODY TECHNOPOLYMER 6 OR GASKET NBR 7 OR GASKET NBR 15 BODY TECHNOPOLYMER 7 6 4 3 2 1 * In contact with liquid Operating Range: ECOTRONIC 110 to 130 From 1 to 21gpm with a head up to 164ft ( 71 psi ) ECOTRONIC 230 to 250 From 1 to 27gpm with a head up to 197ft ( 85 psi ) Liquid quality requirements: clean, free from solids or abrasive substances, non viscous, non aggressive, non crystallized, chemically neutral, close to the characteristics of water Liquid temperature Range: From 32°F to 104°F Maximum suction depth 26 ft Maximum ambient temp. 104°F Maximum operating pressure 116 psi Installation: fixed or portable in a horizontal position Special version on request other voltages and/or frequencies Page 2 ECOTRONIC 110 D C H1 DNA H DNM F E B A MODEL ECOTRONIC 110 A B C D E 15 3/4” 8 3/4” 4 5/8” 9 1/2” 5 3/4” F H H1 DNA DNM Weight /8” 15 1/2” 6 1/2” 1” NPT 1 ” NPT 26.4 lbs 3 ELECTRICAL DATA MODEL P1 Voltage 60Hz Watt 115v 800 ECOTRONIC 110 HYDRAULIC DATA Hp In A Start Pressure MAX Flow Max Head Max Pressure 1/2 8.0 23 psi 16 gpm 138 ft 60 psi ECOTRONIC 120 F D C H1 DNA H DNM F E B A MODEL ECOTRONIC 120 F A B C D E 22 3/4” 8 3/4” 11 5/8” 9 1/2” 5 3/4” F H H1 DNA DNM Weight /8” 15 1/2” 6 1/2” 1” NPT 1 ” NPT 29.5 lbs 3 ELECTRICAL DATA MODEL ECOTRONIC 120 F P1 Voltage 60Hz Watt 115v 1000 HYDRAULIC DATA Hp In A Start Pressure MAX Flow Max Head Max Pressure 3/4 10.0 23 psi 16 gpm 164 ft 71 psi * IF version supplied with a 5” fliter housing and sediment filter housing. Page 3 ECOTRONIC 130 D C H1 DNA H DNM F E B A MODEL ECOTRONIC 130 A B C D E 15 3/4” 8 3/4” 4 5/8” 9 1/2” 5 3/4” F H H1 DNA DNM Weight /8” 15 1/2” 6 1/2” 1” NPT 1 ” NPT 27.2 lbs 3 ELECTRICAL DATA MODEL ECOTRONIC 130 P1 Voltage 60Hz Watt 115v 1250 HYDRAULIC DATA Hp In A Start Pressure MAX Flow Max Head Max Pressure 1 13.0 23 psi 21 gpm 164 ft 71 psi Page 4 ECOTRONIC 230 B A DNM H1 DNA H C F E D MODEL ECOTRONIC 230 A B C D E F H H1 DNA DNM Weight 16 1/8” 9 1/2” 7 1/8” 6 3/4” 8 1/2” 5 5/8” 15 3/8” 5 5/8” 1” NPT 1 ” NPT 26.4 lbs ELECTRICAL DATA MODEL P1 Voltage 60Hz Watt 115v 800 ECOTRONIC 230 HYDRAULIC DATA Hp In A Start Pressure MAX Flow Max Head Max Pressure 1/2 7.5 23 psi 27 gpm 118 ft 51 psi ECOTRONIC 240 F B A C H1 DNA H DNM F E D MODEL ECOTRONIC 240 F A B C D E F H H1 DNA DNM Weight 24 ” 9 1/2” 15 1/4” 6 3/4” 8 1/2” 5 5/8” 15 3/8” 5 5/8” 1” NPT 1 ” NPT 29.5 lbs ELECTRICAL DATA MODEL ECOTRONIC 240 F P1 Voltage 60Hz Watt 115v 1000 HYDRAULIC DATA Hp In A Start Pressure MAX Flow Max Head Max Pressure 3/4 10.0 23 psi 27 gpm 157 ft 68 psi * IF version supplied with a 5” fliter housing and sediment filter housing. Page 5 ECOTRONIC 250 B A DNM H1 DNA H C F E D MODEL ECOTRONIC 250 A B C D E F H H1 DNA DNM Weight 18 ” 9 1/2” 9 1/4” 6 3/4” 8 1/2” 5 5/8” 15 3/8” 5 5/8” 1” NPT 1 ” NPT 27.2 lbs ELECTRICAL DATA MODEL ECOTRONIC 250 P1 Voltage 60Hz Watt 115v 1200 HYDRAULIC DATA Hp In A Start Pressure MAX Flow Max Head Max Pressure 1 13.0 23 psi 27 gpm 197 ft 85 psi Page 6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Create Date : 2015:05:26 10:50:30-04:00 Creator : Adobe InDesign CC 2014 (Windows) Modify Date : 2015:12:09 10:22:10-08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Metadata Date : 2015:12:09 10:22:10-08:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Instance ID : uuid:32df45c0-6102-5d49-bcb7-24f78368efff Original Document ID : xmp.did:98B5A8B4AEF5E011A598DA9DB35A2696 Document ID : xmp.id:1b060ef8-2964-c648-8baf-01703a767cb1 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:e7476f3f-a606-f143-8eaf-61a61507af64 Derived From Document ID : xmp.did:6f4e1974-256d-8a47-8dcf-f391c738a63b Derived From Original Document ID: xmp.did:98B5A8B4AEF5E011A598DA9DB35A2696 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2015:05:26 10:50:30-04:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 6EXIF Metadata provided by EXIF.tools