Ljt22
2017-09-20
: Pdf Ljt22 ljt22 spec products columbia
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
LJT22 2' × 2' LED Troffer PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION Luminaire housing, end caps, and reflectors are die-formed code-gauge cold-rolled steel. Optical system hinges from either side for easy access to LED module and electrical components. Mechanical light trap prevents light leaks. FEATURES FINISH • Full distribution LED troffer • Direct replacement for fluorescent 2x2 • Long-life, 60,000 hour LEDs at L80 reduce life cycle maintenance costs • Four LED color choices and 80 CRI • Many shielding choices • Two door frame choices • Metal to metal light leak protection on all four sides of shielding frame • Fixed output, step dimming (high/low/off), 0-10V dimming, 0-10V dimming-dim to dark drivers available • Hinged optical system allows easy access to LED modules and electrical from below the ceiling • All models standard with IC rating • DesignLights Consortium® (DLC) qualified with many configurations qualifying for DLC Premium; see www.designlights.org • Five year warranty ORDERING INFORMATION LJT 22 – MODEL LJT LED Lensed Troffer COLOR TEMP 30 35 40 50 SIZE 22 2' × 2' VW MW LW ML HL VL 3000K 3500K 4000K 5000K All metal parts processed with a multi-stage phosphate bonding treatment and finished with a high reflectance baked white enamel. CERTIFICATION SHIELDING Lens is high transmission pattern #12 acrylic (A12) for light diffusion without compromise to light output. Other shielding may be specified. If desired shielding media is not shown in ordering guide, contact your local Hubbell Lighting representative. INSTALLATION An access plate is furnished with each recessed fixture for fast wiring connections without the necessity to open the fixture or wireway. – SHIELDING G Grid1 SM Surface Mount CM Cable Mount2 A12 Pattern 12 Acrylic Lens A12125 Pattern 12 Acrylic Lens, 0.125" Nominal A12F Pattern 12 Frosted Acrylic Lens A12125F Pattern 12 Frosted Acrylic Lens, 0.125" Nominal A19 Pattern 19 Acrylic Lens, 0.156" Nominal A19F Pattern 19 Frosted Acrylic Lens 0.156" LUMEN OUTPUT DOOR Very Low Watt Medium Low Watt Low Watt Medium Lumen High Lumen Very High Lumen FS White Flush Steel FA White Flush Aluminum See Product Availability Table below All luminaires are built to UL 1598 and 2108 standards, and bear appropriate CSA labels. Damp location labeling is standard. Emergency equipped fixtures labeled UL924. Adheres to LM79, LM80 and TM21 industry standards. IC rating is standard on all models. DesignLights Consortium® (DLC) and DLC Premium qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. WARRANTY Five year warranty. (Terms and Conditions Apply) EXAMPLE LJT22-35HLG-FSA12-EU U – – CEILING TYPE CEILING COMPATIBILITY Designed for recessed installation in standard inverted tee grid ceilings (G), recessed installation in hard ceilings (G with FK accessory), surface mount at ceiling plane (SM), or cable mount suspension below ceiling plane (CM). For compatibility with specific ceilings contact your Hubbell Lighting representative. DRIVER VOLTAGE Fixed Output Step Dimming 0-10V Dimming 0-10V 1% Dimming EDD 0-10V Dimming, Dim to Dark3 LUTH Hi-lume 1% EcoSystem LED driver with Softon, Fade-toBlack dimming technology 4 LUT5 5-Series EcoSystem LED driver 4 U 120V-277V E ESD ED ED1 C388 C488 C588 TB4 ELL14 GLR GTD G1 G2 G3 CP OPTIONS 3-Wire Flex 4-Wire Flex 5-Wire Flex (4) Bulk T-Bar Clips Emergency Battery Pack Installed, 1400 Lumens4,5 Fast Blow Fuse Generator Transfer Device Single Gasketing (Door to Housing) Double Gasketing (G1 and Lens to Door) Triple Gasketing (G2 and Housing to Ceiling) Chicago Plenum DRIVER AVAILABILITY TABLE For hard ceilings use flange kit accessory. Order hanger accessories separately. 3 50 Watt and Below 4 For compatibility with Dual-LiteGear(R) inverters in lieu of installed battery pack, contact Hubbell Lighting Representative. 5 Not available with 2x2 Surface or Cable Mount. Damp label—standard. IC rating—standard. Page 1/3 Rev. 09/18/17 1 2 E ESD ED ED1 EDD LUTH LUT5 VW X X X X X X MW X X X X X X X LW X X X X X X X ML X X X X X X X HL X X X X X X X © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com VL X X X X X X X ACCESSORIES (ORDER SEPARATELY) FK22 2' × 2' Single Flange Kit CM48Y2SC3F-KIT 48" Cable Mount Kit for 2' wide CM ceiling type, 3 Wire Feed Cord LED / LJT22 LJT22 2' × 2' LED Troffer Product Availability Lumen Package Lumens Input Watts LPW LJT22-50VWG-FSA12-EU 1572 13 120 LJT22-40VWG-FSA12-EU 1443 13 110 LJT22-35VWG-FSA12-EU 1421 13 108 105 LJT22-30VWG-FSA12-EU 1380 13 LJT22-50MWG-FSA12-EU 2130 18 117 LJT22-40MWG-FSA12-EU 1956 18 107 LJT22-35MWG-FSA12-EU 1926 18 106 LJT22-30MWG-FSA12-EU 1870 18 103 LJT22-50LWG-FSA12-EU 2741 24 116 LJT22-40LWG-FSA12-EU 2517 24 106 LJT22-35LWG-FSA12-EU 2479 24 105 LJT22-30LWG-FSA12-EU 2407 24 102 LJT22-50MLG-FSA12-EU 3722 31 119 LJT22-40MLG-FSA12-EU 3419 31 109 LJT22-35MLG-FSA12-EU 3365 31 108 LJT22-30MLG-FSA12-EU 3267 31 104 LJT22-50HLG-FSA12-EU 4074 33 125 114 LJT22-40HLG-FSA12-EU 3743 33 LJT22-35HLG-FSA12-EU 3684 33 113 LJT22-30HLG-FSA12-EU 3577 33 109 LJT22-50VLG-FSA12-EU 4718 42 113 LJT22-40VLG-FSA12-EU 4334 42 104 LJT22-35VLG-FSA12-EU 4265 42 103 LJT22-30VLG-FSA12-EU 4142 42 100 Page 2/3 Rev. 09/18/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / LJT22 PHOTOMETRIC DATA LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet ENERGY DATA LJT22-40LWG-FSA12-EU LJT LED, Lensed Troffer 2' X 2' LED with A12 pattern acrylic prismed lens XI040C110V054BST1 1.00 LED 2518 23.70 Recessed 0º = 90 90º = 90 0º = 1.14 90º = 1.20 Length:1.92 Width: 1.92 Height: 0.00 Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet LJT22-40MLG-FSA12-EU LJT LED, Lensed Troffer 2' X 2' LED with A12 pattern acrylic prismed lens XI040C110V054BST1 1.00 LED 3419 31.30 Recessed 0º = 90 90º = 90 0º = 1.14 90º = 1.20 Length:1.92 Width: 1.92 Height: 0.00 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet 2' × 2' LED Troffer Test 16378 Test Date 06/30/2016 INDOOR CANDELA PLOT INDOOR CANDELA INDOOR CANDELA PLOTPLOT 90 90 75 75 600 600 60 AVERAGE LUMINANCE %Lamp CANDELA/SQ M Zone Lumens %Fixt. ANGLE 0.0 22.5 35.345.0 67.5 90.0 60 0-30 889 35.3 AVERAGE LUMINANCE CANDELA/SQ M 3445 3445 3445 3445 3445 0 0-40 1401 55.6 ANGLE 0.0 22.555.63109 45.0 67.5 90.0 3004 3021 3190 3230 30 3445 344585.72710 3445 3445 3445 0-60400 2600 2157 2615 85.7 2733 2748 3004 3021 3109 3190 3230 30 2350 2366 2387 2370 0-9045 2518 100.02440 100.0 2600 2615 2710 2733 2748 40 2071 2094 2112 2026 2008 50 0-18055 2518 100.0 2350 2366100.0 2440 2387 2370 45 1802 1797 1746 1675 1710 2071 2094 2112 2026 2008 50 1577 1513 1407 1407 1489 60 1200 1802 1797 1746 1675 1710 55 1437 1340 1147 1223 1354 65 1577 1513 1407 1407 1489 60 1434 1306 1033 1161 1323 70 0 1200 15 30 TEST 45 #16381 LJT22-40MLG-FSA12-EU LUMINAIRE: Horiz 0-180 1437Troffer 1340 1147 1223 1354 65 Lensed DATE: 7/13/2016 LJT LED, 1602 1388 1106 1207 1354 75 TEST #16381 LJT22-40MLG-FSA12-EU LUMINAIRE: 2' X 2'80 LED with A12 pattern prismed lens 1480 TOTAL = 1434 1306 acrylic 1033 1161 1323 70 0 15 30LUMINAIRE EFFICIENCY 45100.0 1850 1597 1345 1278 DATE: 7/13/2016 LJT LED, Lensed Troffer Data scaled from test 16.01920 TOTAL LUMENS PER WATT = 109 Horiz 0-180 1602 1388 acrylic 1106 1207 1354 75 2044 1943 1508 1474 1675 2' X 2'85 LED with A12 pattern prismed lens TOTAL LUMINAIRE EFFICIENCY = 100.0 BALLAST: ANSI/IESNA RP-1-2004 COMPLIANCE: NONCOMPLIANT 1850test 16.01920 1597 1345 1278 1480 80 XI040C110V054BST1 Data scaled from TOTAL 90.0 LUMENS PER WATT = 109 0.0 45.0 BALLAST FACTOR: 1.00 COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $2.18 BALLAST: XI040C110V054BST1 2044 1943 1508 1474 1675 ANSI/IESNA RP-1-2004 COMPLIANCE: NONCOMPLIANT LAMP: 85 Led BASED ON 3000 HRS. AND $.08 PER KWH BALLAST FACTOR: 1.00 COMPARATIVE YEARLY COST PER FIXTURE LUMENS: 3419 0.0 LIGHTING ENERGY 45.0 90.0 1000 LUMENS = $2.18 LAMP: Led BASED ON 3000 ZONAL HRS. AND $.08 PER KWH COEFFICIENTS CAVITY METHOD WATTS: 31.30 OF UTILIZATION (%) FIXTURE LUMENS: 3419 MOUNTING: Recessed EFFECTIVE FLOOR CAVITY REFLECTANCE = 20% Test 16381 Test Date 07/13/2016 WATTS: 31.30 SHIELDING ANGLE: 0º = 90 90º (%) = 90 COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD RC 80% 70% 50% 30% 10% 0% MOUNTING: Recessed CANDELA PLOT SPACING CRITERION: 0º = 1.14 90º = 1.20 EFFECTIVE FLOOR CAVITY REFLECTANCE =INDOOR 20% 30% RW 70% 50%0º =30% 10% 50% 30% 10% 50% 30% 10% 50% 10% 50% 30% 10% 0% SHIELDING ANGLE: 90 90º = 90 70% LUMINOUS OPENING IN FEET INDOOR30% CANDELA PLOT 90 RC 0 119 80% 50% 10% 0% SPACING CRITERION: 0º = 1.1411990º =116 1.20 116 70%116 119 116 111 111 111 106 106 106 102 102 102 100 LENGTH: 1.92 119 LUMINOUS OPENING IN FEET RW1 WIDTH: 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0% 110 105 98 107 103 100 96 99 96 93 95 93 91 92 90 88 86 90 1.92 102 1.92 87 Total Luminaire Efficiency 100.0% 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 20 LENGTH: 101 93 82 98 92 86 81 88 83 79 85 81 77 82 79 76 74 HEIGHT: 0.00 119 WIDTH: 1.92 102 110 105 98 107 103 100 96 99 96 93 95 93 91 92 90 88 86 31 HEIGHT: 93 83 76 70 91 82 75 69 79 73 68 76 71 67 74 70 66 64 0.00 Total Lumens per Watt67 109 ZONAL 101 93 87 82 98 92 86 81 88 83 79 85 81 77 82 79 76 74 42 LUMENS 86 75 61 84 74 66 60 71 65 60 69 63 59 67 62 58 56 R 93 RP-1-2004 83 76 70 % FIXTURE 91 82 75 69 79 73 68 76 71 67 74 70 66 64 ANSI/IESNA Noncompliant LUMENS % LAMP 53LUMENS 80 68 59 53 78 67 59 53 65 58 52 63 57 52 61 56 51 49 C ZONE ZONAL 86 1209 75 6735.3 47 84 74 66 60 71 65 60 69 63 59 67 62 58 56 R ZONE 0-30 35.3 Compliance 64 74 62 53 72 61 53 47 59 52 47 57 51 46 56 50 46 44 R 75 LUMENS % LAMP61 % FIXTURE 80 1209 68 5935.3 53 78 67 59 53 65 58 52 63 57 52 61 56 51 49 C 0-30 0-40 1903 55.7 42 55.7 75 69 56 48 67 56 48 54 47 42 53 46 42 51 46 41 39 35.3 Comparative Yearly Lighting $2.18 based on 42 75 74 1903 62 5355.7 47 72 61 53 47 59 52 47 57 51 46 56 50 46 44 R 0-40 0-60 2930 85.7 38 85.7 86 64 52 44 63 51 43 38 50 43 38 49 42 38 47 42 37 36 55.7 Energy Cost per 1000 Lumens 3000 hrs. and 69 2930 56 48100.0 42 67 56 48 42 54 47 42 53 46 42 51 46 41 39 0-90 3419 100.0 97 60 48 40 59 47 40 35 46 39 34 45 39 34 44 38 34 32 0-60 85.7 35 85.7 $0.08 per 64 3419 52 44100.0 32 38 63 51 KWH 43 38 50 43 38 49 42 38 47 42 37 36 0-180 100.0 108 57 44 37 56 44 37 32 43 36 32 42 36 31 41 35 31 30 0-90 3419 100.0 100.0 9 60 48 40 35 59 47 40 35 46 800 39 34 45 39 34 44 38 34 32 0-180 3419 RATIO 100.0RC = EFFECTIVE 100.0 RCR = ROOM CAVITY CEILING CAVITY REFLECTANCE RW = WALL REFLECTANCE 10 57 44 37 32 56 44 37 32 43 800 36 32 42 36 31 41 35 31 30 INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY RCRDATA = ROOM CAVITY RATIOARERC = EFFECTIVE CEILING CAVITY REFLECTANCE RW = WALL REFLECTANCE 60 THE IN THIS REPORT BASED ON ABSOLUTE MEASUREMENTS. Zone Lumens %Lamp %Fixt. AVERAGE CANDELA/SQ M MEASUREMENTS. ANSI/IESNALUMINANCE RP-1 COMPLIANCE IS BASED ON ABSOLUTE 60 0-30 1209 35.3 35.3 THIS TEST RUN IN ACCORDANCE WITH CURRENT I.E.S.N.A. PUBLISHED PROCEDURES. ANGLE 0.0 22.5 45.0 67.5 90.0 THE DATALUMINANCE IN THIS REPORT ARE BASED ON ABSOLUTE AVERAGE CANDELA/SQ M MEASUREMENTS. ANSI/IESNA IS BASED ON ABSOLUTE MEASUREMENTS. 4681 4681 4681 4681 0-40 0 RP-1 1903 55.7 ANGLE 0.0 COMPLIANCE 22.5 55.74681 45.0 67.5 90.0 APPROVED BY:______________ THIS TEST WITH 4333 CURRENT I.E.S.N.A. PUBLISHED PROCEDURES. 4090IN ACCORDANCE 4113 4231 4383 30 RUN 4681 4681 4681 0-60400 2930 4681 85.74681 85.7 3541 3560 3678 3720 3739 4090 4113 4231 4333 4383 30 APPROVED BY:______________ 0-9040 3419 100.0 100.0 3200 3229 3324 3250 3213 45 3541 3560 3678 3720 3739 Tel 864 678 2807 2835 2862 2744 27261000 701 Millennium Blvd. Greenville, SC 29607 50 3200 3229 3324 3250 3213 45 0-180 3419 100.0 100.0 2454 2444 2362 2281 2316 55 2807 2835 2862 2744 50 Tel 864 2726 678 1000 701 Millennium Blvd. Greenville, SC 29607 2137 2073 1898 1910 2003 60 2454 2444 2362 2281 2316 55 1600 1935 1803 1561 1651 1831 65 2137 2073 1898 1910 2003 60 1946 1767 1409 1579 1784 70 0 1600 15 30 45 1935 1803 1561 1651 1831 65 TEST #16384 LJT22-40HLG-FSA12-EU LUMINAIRE: Horiz 0-180 2177 Troffer 1884 1500 1636 1828 75 Lensed DATE: 7/13/2016 LJT 70 LED, 1946 1767 1409 1579 1784 0 15 30 45 2505 2152 acrylic 1799prismed 1749 2018 80 2' X 75 2' LED 2177 with A12 pattern lens 1828 TEST = #16384 LJT22-40HLG-FSA12-EU TOTAL 100.0 LUMINAIRE: Horiz 0-180 LUMINAIRE EFFICIENCY 1884 1500 1636 Data scaled from test 16.019211799 DATE: 7/13/2016 LJT 80 LED, Lensed Troffer 2814 2647 2044 2010 2278 TOTAL LUMENS PER WATT = 114 85 2505 2152 1749 2018 BALLAST: XI040C110V054BST1 2' X 2' LED with A12 pattern acrylic prismed lens TOTAL COMPLIANCE: LUMINAIRE EFFICIENCY = 100.0 ANSI/IESNA RP-1-2004 NONCOMPLIANT 0.0 45.0 90.0 2814 2647 2010 2278 BALLAST FACTOR: 1.00 Data85scaled from test 16.019212044 LUMENS WATT = 114 COMPARATIVE YEARLY LIGHTING ENERGYTOTAL COST PER 1000 PER LUMENS = $2.12 LAMP: Led XI040C110V054BST1 BALLAST: NONCOMPLIANT 0.0ANSI/IESNA RP-1-2004 45.0 BASED ONCOMPLIANCE: 300090.0 HRS. AND $.08 PER KWH FIXTURE BALLAST LUMENS: FACTOR: 3743 1.00 COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $2.12 COEFFICIENTS OF UTILIZATION (%) ZONAL CAVITY METHOD WATTS: 32.70 LAMP: Led BASED ON 3000 HRS. AND $.08 PER KWH Date 07/13/2016 EFFECTIVE FLOOR CAVITY REFLECTANCE = 20% Test 16384 TestZONAL MOUNTING: Recessed FIXTURE LUMENS: 3743 COEFFICIENTS OF UTILIZATION (%) CAVITY METHOD SHIELDING ANGLE:80% 0º = 90 90º = 90 WATTS: 32.70 RC 70% 50% 10% 0% EFFECTIVE FLOOR CAVITY REFLECTANCE = INDOOR 20% 30% CANDELA PLOT SPACING CRITERION: 0º = 1.14 = 1.20 50% MOUNTING: Recessed RW 70% 50%80%30% 10%90º 70% 10% 50% 50% 30% 10% 50% 30% 30% 10% 50% 10% 30% 10% 0% RC 70%30% 0% LUMINOUS FEET SHIELDING ANGLE: = 90 90º 90 119OPENING 119 0ºIN 119 119= 90 70% 116 116 116 116 111 111 111 106 106 106 PLOT 102 102 102 100 INDOOR CANDELA RW 0 70% 50% 10% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0% LENGTH: 1.9230% SPACING CRITERION: 0º = 1.14 90º = 1.20 50% 110 105 102 98 107 103 100 96 99 96 93 95 93 91 92 90 88 86 01 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 WIDTH: 1.92IN119 LUMINOUS OPENING FEET 119 Total Luminaire Efficiency 100.0% 90 101 940.00 87 82 98 92 86 81 88 83 79 85 81 78 82 79 76 74 HEIGHT: LENGTH: 1.92102 12 110 105 98 107 103 100 96 99 96 93 95 93 91 92 90 88 86 93 831.92 76 70 91 82 75 69 79 73 68 76 71 67 74 70 66 64 WIDTH: Total Lumens per Watt87 114 23 101 94 82 98 92 86 81 88 83 79 85 81 78 82 79 76 74 HEIGHT: LUMENS 86 750.00 76 67 61 84 74 66 60 71 65 60 69 63 59 67 62 58 56 RZONAL 34 93 83 70 91 82 75 69 79 73 68 76 71 67 74 70 66 64 ANSI/IESNA RP-1-2004 Noncompliant 80 LUMENS 68 59% LAMP 53 % FIXTURE 78 67 59 53 65 58 53 63 57 52 61 56 51 49 C ZONE 45 LUMENS 86 75 67 61 84 74 66 60 71 65 60 69 63 59 67 62 58 56 R ZONAL Compliance 1321 35.3 67 74 62 53 35.353 47 72 61 53 47 59 52 47 57 51 46 56 50 46 44 R 0-30 75 56 80 68 59 78 59 53 65 58 53 63 57 52 61 56 51 49 C ZONE LAMP 0-40 2081 55.6 based 69 LUMENS 56 Lighting 48% 55.6 42 % FIXTURE 67 56 48 42 54 47 42 53 46 42 51 46 41 40 Comparative Yearly $2.12 on 47 67 74 62 53 72 53 59 52 47 57 51 46 56 50 46 44 R 0-30 1321 35.347 35.3 61 0-60 3206 85.7 75 8 Cost 64 per 52 44 85.7 38 63 51 and 43 38 50 43 38 49 42 38 47 42 37 36 Energy 1000 Lumens 3000 hrs. 7 69 56 48 42 67 56 48 42 54 47 42 53 46 42 51 46 41 40 0-40 2081 55.635 55.6 47 0-90 3743 100.0 60 48 40 100.0 59 40 35 46 39 34 45 39 34 44 38 34 32 $0.08 per KWH 89 64 52 44 63 43 38 50 43 38 49 42 38 47 42 37 36 0-60 3206 85.738 85.7 51 0-180 3743 100.0 10 57 44 37 100.0 32 56 44 37 32 43 36 32 42 36 31 41 35 31 30 9 60 48 40 35 59 47 40 35 46 39 34 45 39 34 44 38 34 32 0-90 3743 100.0 100.0 900 57 CAVITY 44 RATIO 37 100.0 32 = EFFECTIVE 56 37 CAVITY 32 REFLECTANCE 43 36 32 42 REFLECTANCE 36 31 41 35 31 30 RCR10 = ROOM RC RW = WALL 0-180 3743 100.0 44CEILING ENERGY DATA LJT22-40HLG-FSA12-EU LJT LED, Lensed Troffer 2' X 2' LED with A12 pattern acrylic prismed lens XI040C110V054BST1 1.00 LED 3743 32.70 Recessed 0º = 90 90º = 90 0º = 1.14 90º = 1.20 Length:1.92 Width: 1.92 Height: 0.00 LJT22 TEST #16378 DATE: 6/30/2016 TOTAL LUMINAIRE EFFICIENCY 100.0 TEST =#16378 TOTAL LUMENS PER WATT = 106 DATE: 6/30/2016 ANSI/IESNA RP-1-2004 NONCOMPLIANT TOTAL COMPLIANCE: LUMINAIRE EFFICIENCY = 100.0 COMPARATIVE YEARLY LIGHTING ENERGY TOTAL COST PER 1000 LUMENS = $2.29 LUMENS PER WATT = 106 BASED ONCOMPLIANCE: 3000 HRS. AND $.08 PER KWH ANSI/IESNA RP-1-2004 NONCOMPLIANT COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $2.29 BASED ON 3000 HRS. AND $.08 PER KWH ZONAL LUMEN SUMMARY ENERGY DATA LUMINAIRE DATA Luminaire LUMINAIRE: LJT22-40LWG-FSA12-EU LJT LED, Lensed Troffer 2' X 2' LED with A12 pattern acrylic prismed lens LJT22-40LWG-FSA12-EU LUMINAIRE: Data scaled from test 16.01561 LJT LED, Lensed Troffer BALLAST: XI040C110V054BST1 2' X 2' LED with A12 pattern acrylic prismed lens BALLAST FACTOR: 1.00 Data scaled from test 16.01561 LAMP: Led XI040C110V054BST1 BALLAST: FIXTURE BALLASTLUMENS: FACTOR:2518 1.00 WATTS: 23.70 LAMP: Led MOUNTING: Recessed FIXTURE LUMENS: 2518 SHIELDING ANGLE: 0º = 90 90º = 90 WATTS: 23.70 SPACING CRITERION: MOUNTING: Recessed 0º = 1.14 90º = 1.20 LUMINOUS IN=FEET SHIELDINGOPENING ANGLE: 0º 90 90º = 90 1.92 0º = 1.14 90º = 1.20 SPACINGLENGTH: CRITERION: WIDTH: 1.92 IN FEET LUMINOUS OPENING Total Luminaire Efficiency 100.0% HEIGHT: 0.00 LENGTH: 1.92 WIDTH: 1.92 Total Lumens per0.00 Watt 106 ZONAL LUMENS HEIGHT: ZONE LUMENS % LAMP % FIXTURE ANSI/IESNA RP-1-2004 Noncompliant ZONAL LUMENS 0-30 889 35.3 35.3 Compliance ZONE LUMENS %55.6 LAMP % FIXTURE 0-40 1401 55.6 Comparative Yearly $2.29 based on 0-30 889 Lighting 35.3 35.3 0-60 2157 85.7 85.7 Energy 1000 Lumens 3000 0-40Cost per 1401 55.6 55.6 hrs. and 0-90 2518 100.0 100.0 0-60 2157 85.7 85.7 $0.08 per KWH 0-180 2518 100.0 100.0 0-90 2518 100.0 100.0 0-180 2518 100.0 100.0 INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY 900 RCR = ROOM CAVITY RATIO RC = EFFECTIVE CEILING CAVITY REFLECTANCE RW = WALL REFLECTANCE 60 Zone %Lamp %Fixt. THE DATA Lumens IN THIS REPORT ARE BASED ON ABSOLUTE MEASUREMENTS. AVERAGE LUMINANCE CANDELA/SQ M MEASUREMENTS. ANSI/IESNA RP-1 COMPLIANCE IS BASED ON ABSOLUTE 0-30 1321 35.3 35.3 THE DATA IN THIS REPORT ARE BASED ON ABSOLUTE MEASUREMENTS. ANGLE 22.5 45.0 67.5 90.0 60 THIS TEST RUN0.0 IN ACCORDANCE WITH CURRENT I.E.S.N.A. PUBLISHED PROCEDURES. ANSI/IESNA RP-1 COMPLIANCE IS BASED ON ABSOLUTE AVERAGE M MEASUREMENTS. 5116 511655.6 5116 CANDELA/SQ 5116 5116 0 LUMINANCE 0-40 2081 55.6 THIS TEST RUN 0.0 IN ACCORDANCE WITH CURRENT I.E.S.N.A. PUBLISHED PROCEDURES. ANGLE 22.5 45.0 67.5 90.0 APPROVED BY:______________ 4464 4498 4622 4744 4791 0-60 300 3206 85.7 85.7 5116 5116 5116 5116 5116 3865 3899 4021 4075 4086 40 APPROVED BY:______________ 4464 4498 4622 100.0 4744 4791 0-90 45 3743 100.03630 30 3477 3531 3572 3506 3865 3899 4021 100.0 4075 4086 40 Tel 864 678 1000 701 Millennium Blvd. Greenville, SC 29607 3066 3130 3016 2994 0-180 50 3743 100.03143 3477 3531 3630 3572 3506 45 2673 2678 2596 2505 2535 55 Tel 864 678 1000 701 Millennium Blvd. Greenville, SC 29607 3066 3130 3143 3016 2994 50 2324 2260 2091 2096 2196 60 1800 2673 2678 2596 2505 2535 55 2128 1990 1707 1817 2004 65 2324 2260 2091 2096 2196 60 2126 1946 1545 1742 1955 70 0 1800 15 30 45 2128 1990 1707 1817 2004 65 Horiz 0-180 2369 2065 1647 1805 2008 75 2126 1946 1545 1742 1955 70 0 15 30 45 2758 2371 1967 1917 2203 80 Horiz 0-180 2369 2065 1647 1805 2008 75 3049 2915 2245 2178 2479 85 2758 2371 1967 1917 2203 80 0.0 45.0 90.0 3049 2915 2245 2178 2479 85 COEFFICIENTS OF UTILIZATION (%) 0.0 EFFECTIVE FLOOR CAVITY REFLECTANCE = 20% COEFFICIENTS OF UTILIZATION (%) RC 80% 70% 50% 20% RW 70% 50% 30% 10% 70% EFFECTIVE 50% 30%FLOOR 10% CAVITY 50% REFLECTANCE 30% 10% =50% Page 3/3 Rev. 09/18/17 RC 0 119 50% 119 80%119 119 116 116 70%116 116 111 111 111 106 RW 1 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 110 105 102 98 107 103 100 96 99 96 93 95 0 101 119 119 119 116 116 116 116 111 111 111 106 93change 87 without 82 98 92 86 81 88 83 79 85 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications 2subject to119 notice. 105 102 98 107 103 100 96 99 96 93 95 31 110 93 83 76 70 91 82 75 69 79 73 68 76 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / WebsiteRwww.columbialighting.com 2 101 93 87 82 98 92 86 81 88 83 79 85 4 86 75 67 61 84 74 66 60 71 65 60 69 93 83 76 70 91 82 75 69 79 73 68 76 53 80 68 59 53 78 67 59 53 65 58 52 63 C 86 75 67 61 84 74 66 60 71 65 60 69 R 64 74 62 53 47 72 61 53 47 59 52 47 57 R 80 68 59 53 78 67 59 53 65 58 52 63 C 75 69 56 48 42 67 55 48 42 54 47 42 53 6 74 62 53 47 72 61 53 47 59 52 47 57 R 8 64 52 44 38 63 51 43 38 50 43 38 49 45.0 30% 30% 30% 106 30% 93 106 81 93 71 81 63 71 57 63 51 57 46 51 42 90.0 ZONAL CAVITY METHOD 10% 106 10% 91 106 77 91 67 77 59 67 52 59 46 52 42 46 38 ZONAL 10%CAVITY METHOD 0% 30% 0% LED10% / LJT22 10% 0% 102 102 100 30% 10% 0% 90 88 86 102 102 100 79 76 74 90 88 86 70 66 64 79 76 74 62 58 56 70 66 64 56 51 49 62 58 56 50 46 44 56 51 49 46 41 39 50 46 44 42 37 36 50% 102 50% 92 102 82 92 74 82 67 74 61 67 56 61 51 56 47 LJT22 2' × 2' LED Troffer DIMENSIONAL DATA CEILING COMPATIBILITY Type G 4¼" Side End 24" For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. LJT22 FK22 Flange Kit 24" Side 3" End 41/2" A For hard ceiling applications order FK22 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. K 161/2" FKCR A - 7/8" Diameter Knockout K - 2" × 3" through hole for access plate NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK22 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK22 & (1) FKCR) Row cut out dimensions using FK22 & FKCR adapters: Width 243/8", Length [24" × (# in row)] + 3/4". Example: (24" × 2) + 3/8"= 483/8" Flange kit rough in dimensions for single unit only: 243/8" × 243/8" DIMENSIONAL DATA - SURFACE MOUNT (SM) OR CABLE MOUNT (CM) 59⁄16" NOTE: 215⁄8" Mounting Holes: (4) 1⁄4–1⁄2" DIA KOs (A) All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. 123⁄8" 25" 15" Side View 11⁄2" Thru Hole 41⁄2" x 5" Mounting Collar (SM only). For Cable Mount (CM) a 2" x 3" access plate with (2) 7⁄8" K.O.s provided in place of Mounting Collar shown. 45⁄8" End View SURFACE MOUNT CABLE MOUNT Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 1⁄4" to 1⁄2" provided as shown, marked "A". Order CM ceiling type. Access plate supplied for cable mounting or suspension. Use CM48Y2C3F-KIT 48" cable mount kit. Includes 3 wire feed cord. For other wiring needs, contact Hubbell Lighting representative. Mounting knock-outs, 1⁄4" to 1⁄2", provided as shown, marked "A". Page 4/3 Rev. 09/18/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / LJT22