NEI FCCE 1 E0903103

Nei-Fcce-1-E0903103 NEI-FCCE-1-E0903103 NEI-FCCE-1-E0903103 CertsReports 130042 ProductFiles assets.mhint

2016-04-05

: Pdf Nei-Fcce-1-E0903103 NEI-FCCE-1-E0903103 CertsReports 130028 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 22

DownloadNEI-FCCE-1-E0903103
Open PDF In BrowserView PDF
Neutron Engineering Inc.

FCC Test Report
Apr. 09, 2009
E0903103
2.5” SATA HDD External Enclosure
SUB2A8

Issued Date
Project No.
Equipment
Model Name

:
:
:
:

Applicant
Address

: Age Star Inc.
: 6F-1, No. 23, Sec. 1, Sichuan Road,
Banqiao City 22063, Taipei Hsien,
Taiwan

Tested by:
Neutron Engineering Inc. EMC Laboratory
Date of Test:
Mar. 24, 2009 ~ Apr. 08, 2009

Te s t i n g E n g i n e e r :
(Pike Lee)

Technical Manager :
(Jeff Yang)

Authorized Signatory :
(Andy Chiu)

Neutron Engineering Inc.
B1, No. 37, Lane 365, YangGuang St.,
NeiHu District 114, Taipei, Taiwan.
TEL: +886-2-2657-3299
FAX: +886-2-2657-3331

Report No.: NEI-FCCE-1-E0903103

Page 1 of 22

Neutron Engineering Inc.
Declaration
Neutron represents to the client that testing is done in accordance with standard procedures as applicable
and that test instruments used has been calibrated with the standards traceable to National Measurement
Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A.
Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s
responsibility to ensure that additional production units of this model are manufactured with the identical
electrical and mechanical components. Neutron shall have no liability for any declarations, inferences or
generalizations drawn by the client or others from Neutron issued reports.
Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any
agency of the Government.
This report is the confidential property of the client. As a mutual protection to the clients, the public and
Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized
written approval.
Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025
requirements, and accredited by the conformity assessment authorities listed in this test report.

Limitation
For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
test report is (are) included in the conformity assessment authorities acceptance respective.

Report No.: NEI-FCCE-1-E0903103

Page 2 of 22

Neutron Engineering Inc.

Table of Contents

Page

1 . CERTIFICATION

4

2 . SUMMARY OF TEST RESULTS

5

2.1 TEST FACILITY

6

2.2 MEASUREMENT UNCERTAINTY

6

3 . GENERAL INFORMATION

7

3.1 GENERAL DESCRIPTION OF EUT

7

3.2 DESCRIPTION OF TEST MODES

8

3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

9

3.4 DESCRIPTION OF SUPPORT UNITS

4 . EMC EMISSION TEST

10

11

4.1 CONDUCTED EMISSION MEASUREMENT
4.1.1 POWER LINE CONDUCTED EMISSION
4.1.2 MEASUREMENT INSTRUMENTS LIST
4.1.3 TEST PROCEDURE
4.1.4 DEVIATION FROM TEST STANDARD
4.1.5 TEST SETUP
4.1.6 EUT OPERATING CONDITIONS
4.1.7 TEST RESULTS

11
11
11
12
12
12
13
14

4.2 RADIATED EMISSION MEASUREMENT
4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT
4.2.2 MEASUREMENT INSTRUMENTS LIST
4.2.3 TEST PROCEDURE
4.2.4 DEVIATION FROM TEST STANDARD
4.2.5 TEST SETUP
4.2.6 EUT OPERATING CONDITIONS
4.2.7 TEST RESULTS

16
16
17
17
17
18
18
19

5 . EUT TEST PHOTO

Report No.: NEI-FCCE-1-E0903103

21

Page 3 of 22

Neutron Engineering Inc.
1. CERTIFICATION
Equipment :
Brand Name :
Model Name :
Applicant:
Date of Test :
Sta n d a r d s :

2.5” SATA HDD External Enclosure
AGE STAR
SUB2A8
Age Star Inc.
Mar. 24, 2009 ~ Apr. 08, 2009
FCC Part 15, Subpart B, Class B
CISPR 22: 1997+A1: 2000, Class B
ICES-003: 2004, Class B
ANSI C63.4-2003

The above equipment has been tested and found compliance with the requirement of the relative
standards by Neutron Engineering Inc. EMC Laboratory.
The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
NEI-FCCE-1-E0903103) were obtained utilizing the test procedures, test instruments, test sites
that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality
assessment standard and technical standard(s).

Report No.: NEI-FCCE-1-E0903103

Page 4 of 22

Neutron Engineering Inc.
2. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
Emission
Standard

Test Item

Limit

Judgment

FCC Part15, Subpart B
CISPR 22:1997+A1: 2000
ICES-003: 2004

Conducted Emission

Class B

PASS

Radiated Emission

Class B

PASS

Remark

NOTE:
(1) ” N/A” denotes test is not applicable in this Test Report.
(2) For client’s request and manual description, the test will not be executed.

Report No.: NEI-FCCE-1-E0903103

Page 5 of 22

Neutron Engineering Inc.
2.1 TEST FACILITY
The test facilities used to collect the test data in this report is C01/OS02 at the location of
No.132-1, Lane 329, Sec. 2, Palian Road, Shijr City, Taipei, Taiwan.
2.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95%。
A. Conducted Measurement :
Test Site
C01

Method
ANSI

Measurement Frequency Range
150 KHz ~ 30MHz

U,(dB)
1.94

NOTE

U,(dB)

NOTE

B. Radiated Measurement :
Test Site

Method

OS-01

ANSI

OS-02

ANSI

Measurement Frequency
Range
30MHz ~ 200MHz
30MHz ~ 200MHz
200MHz ~ 1,000MHz
200MHz ~ 1,000MHz
30MHz ~ 200MHz
30MHz ~ 200MHz
200MHz ~ 1,000MHz
200MHz ~ 1,000MHz

Report No.: NEI-FCCE-1-E0903103

Ant.
H/V
V
H
V
H
V
H
V
H

2.86
2.56
2.88
2.98
2.48
2.16
2.50
2.66

Page 6 of 22

Neutron Engineering Inc.
3. GENERAL INFORMATION
3.1 GENERAL DESCRIPTION OF EUT

Equipment

2.5” SATA HDD External Enclosure

Brand Name

AGE STAR

Model Name

SUB2A8

OEM Brand/Model Name N/A

Power Source

N/A
The EUT is a 2.5” SATA HDD External Enclosure.
Based on the application, features, or specification
exhibited in User's Manual, the EUT is considered as an
ITE/Computing Device. More details of EUT technical
specification, please refer to the User's Manual.
Supplied from PC USB port.

Power Rating

N/A

Connecting I/O Port(s)

Please refer to the User's Manual

Products Covered

N/A

EUT Modification(s)

N/A

Model Difference

Product Description

Note:
1. For a more detailed features description, please refer to the manufacturer’s specifications
or the User's Manual.

Report No.: NEI-FCCE-1-E0903103

Page 7 of 22

Neutron Engineering Inc.

3.2 DESCRIPTION OF TEST MODES
To investigate the maximum EMI emission characteristics generates from EUT, the test system
was pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT
operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.
Pretest Test Mode

Description

Mode 1

USB READ/WRITE

For Conducted Test
Final Test Mode

Description

Mode 1

USB READ/WRITE
For Radiated Test

Final Test Mode

Description

Mode 1

USB READ/WRITE

Report No.: NEI-FCCE-1-E0903103

Page 8 of 22

Neutron Engineering Inc.

3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

C-1

C-6
E-1
EUT

E-2 Monitor

C-2
E-3 Keyboard

C-5
E-7
PC

E-5
Modem

C-4
E-6
Printer

C-3
E-4
Mouse
C-1 D-SUB Cable
C-2 PS/2 Cable
C-3 PS/2 Cable
C-4 Parallel Cable
C-5 RS232 Cable
C-6 USB Cable

Report No.: NEI-FCCE-1-E0903103

Page 9 of 22

Neutron Engineering Inc.

3.4 DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item

E-3

Equipment
2.5” SATA
HDD
External
Enclosure
19” LCD
Monitor
PS/2 K/B

E-4

PS/2 Mouse

Logitech

M-SBF69

DOC

HCA44601156

E-5

Modem

ACEEX

DM-1414V

DOC

8041708

E-6

Printer

SII

DOC

1045105A

E-7

PC

HP

DPU-414
HP Compaq
dx7300 MT

DOC

SGH71505LH

E-1
E-2

Mfr/Brand

Model/Type No.

FCC ID

Series No.

Note

AGE STAR

SUB2A8

DOC

N/A

EUT

Samsung

SyncMaster 193P

DOC

DI19H4JXC05517A

Logitech

Y-SJ17(ACK260A)

DOC

SYU44664880

Item

Shielded Type

Ferrite Core

Length

C-1

YES

YES

1.8M

C-2

YES

NO

1.5M

C-3

YES

NO

1.7M

C-4

YES

NO

1.8M

C-5

YES

NO

1.7M

C-6

YES

NO

1.0M

Note

Note:
(1)
(2)

The support equipment was authorized by Declaration of Conformity.
For detachable type I/O cable should be specified the length in cm in『Length』column.

Report No.: NEI-FCCE-1-E0903103

Page 10 of 22

Neutron Engineering Inc.

4. EMC EMISSION TEST
4.1 CONDUCTED EMISSION MEASUREMENT
4.1.1 POWER LINE CONDUCTED EMISSION (FREQUENCY RANGE 150KHZ-30MHZ)
FREQUENCY (MHz)

Class A (dBuV)

Class B (dBuV)

Quasi-peak

Average

Quasi-peak

Average

0.15 -0.5

79.00

66.00

66 - 56 *

56 - 46 *

0.50 -5.0

73.00

60.00

56.00

46.00

5.0 -30.0
73.00
60.00
60.00
50.00
Note:
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the
logarithm of the frequency in the range.
4.1.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment

Manufacturer

1

Test Cable

N/A

2

LISN

EMCO

Type No.
SR03_C_01
&02
3816/2

Serial No.

Calibrated until

N/A

Oct. 19, 2009

00042991

Jan. 21, 2010

3

Pulse Limiter

Electro-Metrics

EM-7600

112644

Dec. 28, 2009

4

50Ω Terminator

N/A

N/A

N/A

May 13, 2009

5

EMI Test Receiver

R&S

ESCI

100082

Mar. 17, 2010

6

LISN

EMCO

3816/2

00066528

Apr. 27, 2009

Remark: ” N/A” denotes No Model Name , Serial No. or No Calibration specified.

Report No.: NEI-FCCE-1-E0903103

Page 11 of 22

Neutron Engineering Inc.

4.1.3 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
to the power mains through a line impedance stabilization network (LISN). All other support
equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall
length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
4.1.4 DEVIATION FROM TEST STANDARD
No deviation
4.1.5 TEST SETUP

Vertical Reference Ground Plane

40 cm

EUT

Test Receiver

80 cm

LISN
Horizontal Reference Ground Plane

Report No.: NEI-FCCE-1-E0903103

Page 12 of 22

Neutron Engineering Inc.

4.1.6 EUT OPERATING CONDITIONS
The EUT exercise program (EMC.exe) used during radiated and/or conducted emission
measurement was designed to exercise the various system components in a manner similar to a
typical use. The program contained on a PC hard disk and is auto-starting on power-up. Once
loaded, the program sequentially exercises each system component in turn. The sequence used
is:
1. Read (write) from (to) mass storage device (EUT).
2. Send "H" pattern to video port device (Monitor).
3. Send " H " pattern to parallel port device (Printer).
4. Send " H " pattern to serial port device (Modem).
5. Repeated from 2 to 4 continuously.
As the keyboard and mouse are strictly input devices, no data is transmitted to (from) them during
test. They are, however, continuously scanned for data input activity.

Report No.: NEI-FCCE-1-E0903103

Page 13 of 22

Neutron Engineering Inc.

4.1.7 TEST RESULTS
E.U.T :
Temperature :
Test Voltage :
Test Mode :

2.5” SATA HDD External
Enclosure
25°C
AC 120V/60Hz
USB READ/WRITE

Freq.

Terminal

(MHz)
0.18
0.24
0.30
0.88
8.46
12.85

L/N
Line
Line
Line
Line
Line
Line

Measured(dBuV)
QP-Mode
50.67
42.75
41.13
35.56
47.99
40.89

AV-Mode
*
*
*
*
40.21
*

Model Name :

SUB2A8

Relative Humidity : 60%

Limits(dBuV)
QP-Mode
64.63
62.17
60.32
56.00
60.00
60.00

AV-Mode
54.63
52.17
50.32
46.00
50.00
50.00

Margin
(dB)
-13.96
-19.42
-19.19
-20.44
-9.79
-19.11

Note
(QP)
(QP)
(QP)
(QP)
(AV)
(QP)

Remark
:
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.2 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.2 sec./MHz。
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』
. If the QP
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
(3) Measuring frequency range from 150KHz to 30MHz。

Report No.: NEI-FCCE-1-E0903103

Page 14 of 22

Neutron Engineering Inc.

E.U.T :
Temperature :
Test Voltage :
Test Mode :

2.5” SATA HDD External
Enclosure
25°C
AC 120V/60Hz
USB READ/WRITE

Freq.

Terminal

(MHz)
0.18
0.24
0.30
0.88
8.64
11.68

L/N
Neutral
Neutral
Neutral
Neutral
Neutral
Neutral

Measured(dBuV)
QP-Mode
52.10
43.95
40.75
35.38
48.25
40.54

AV-Mode
*
*
*
*
41.20
*

Model Name :

SUB2A8

Relative Humidity : 60%

Limits(dBuV)
QP-Mode
64.55
62.22
60.37
56.00
60.00
60.00

AV-Mode
54.55
52.22
50.37
46.00
50.00
50.00

Margin
(dB)
-12.45
-18.27
-19.62
-20.62
-8.80
-19.46

Note
(QP)
(QP)
(QP)
(QP)
(AV)
(QP)

Remark
:
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.2 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.2 sec./MHz。
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』
. If the QP
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
(3) Measuring frequency range from 150KHz to 30MHz。

Report No.: NEI-FCCE-1-E0903103

Page 15 of 22

Neutron Engineering Inc.

4.2 RADIATED EMISSION MEASUREMENT
4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT (BELOW 1000MHZ)
FREQUENCY (MHz)

Class A (at 10m)

Class B (at 10m)

dBuV/m

dBuV/m

40

30

30 – 230

230 – 1000
47
37
Notes:
(1) The limit for radiated test was performed according to as following:
CISPR 22/ FCC PART 15B /ICES-003.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m).
LIMITS OF RADIATED EMISSION MEASUREMENT (ABOVE 1000MHZ)

FREQUENCY (MHz)

Class A (dBuV/m) (at 3m)

Above 1000

Class B (dBuV/m) (at 3m)

PEAK

AVERAGE

PEAK

AVERAGE

80

60

74

54

Notes:
(1) The limit for radiated test was performed according to FCC PART 15B.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m).
FREQUENCY RANGE OF RADIATED MEASUREMENT (FOR UNINTENTIONAL
RADIATORS)
Highest frequency generated or Upper
frequency of measurement used in the
device or on which the device operates
or tunes (MHz)

Range (MHz)

Below 1.705

30

1.705 – 108

1000

108 – 500

2000

500 – 1000

5000
5 harmonic of the highest frequency or
40 GHz, whichever is lower

Above 1000

Report No.: NEI-FCCE-1-E0903103

th

Page 16 of 22

Neutron Engineering Inc.

4.2.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Turn Table
1

Manufacturer
Chance Most

Type No.
CMTB-1.5

Serial No.
N/A

Calibrated until
N/A

2

Log-Bicon Antenna

Schwarzbeck

VULB 9160

3173

Jul. 02, 2009

3

Test Cable

N/A

10M_OS02

N/A

Oct. 08, 2009

4

Test Cable

N/A

OS02

N/A

Oct. 08, 2009

5

Pre-Amplifier

Anritsu

MH648A

M98457

Nov. 26, 2010

6

EMI Test Receiver

R&S

ESCI

100082

Mar. 17, 2010

7

System Controller
(OS02)

CT

SC100

N/A

N/A

Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified.

4.2.3 TEST PROCEDURE
a. The measuring distance of at 10 m shall be used for measurements at frequency up to 1GHz.
For frequencies above 1GHz, any suitable measuring distance may be used.
b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m or 10
meter open area test site. The table was rotated 360 degrees to determine the position of the
highest radiation.
c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
antenna are set to make the measurement.
d. The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode
pre-scanning the measurement frequency range. Significant peaks are then marked and then
Quasi Peak detector mode re-measured.
e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
performed.
f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
4.2.4 DEVIATION FROM TEST STANDARD
No deviation

Report No.: NEI-FCCE-1-E0903103

Page 17 of 22

Neutron Engineering Inc.

4.2.5 TEST SETUP

3 or 10 m
EUT

1-4 m

80 cm

Ground Plane

Test
Receiver

Amp.

4.2.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.

Report No.: NEI-FCCE-1-E0903103

Page 18 of 22

Neutron Engineering Inc.

4.2.7 TEST RESULTS
2.5” SATA HDD External
Enclosure
17°C
AC 120V/60Hz
USB READ/WRITE

E.U.T :
Temperature :
Test Voltage :
Test Mode :
Freq.
(MHz)
168.00
192.01
240.00
479.99
720.03
960.86

Ant.
H/V
V
V
V
V
V
V

Model Name :

Relative Humidity : 72%

Reading(RA) Corr.Factor(CF) Measured(FS)
(dBuV)
(dB)
(dBuV/m)
24.97
30.50
-5.53
33.50
37.90
29.70
26.25
20.06

SUB2A8

Limits(QP)
(dBuV/m)
30.00

Margin
(dB)
- 5.03

(QP)
(QP)

-7.66
-6.26

25.84
31.64

30.00
37.00

-

4.16
5.36

0.11
4.96
9.25

29.81
31.21

37.00
37.00

-

7.19
5.79

29.31

37.00

-

7.69

Note

(QP)

Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measure-ment
didn‘t perform。
(3) Measuring frequency range from 30MHz to 1000MHz。
(4) If the peak scan value is under the limit for more than 20dB, the signal will not show in
table。

Report No.: NEI-FCCE-1-E0903103

Page 19 of 22

Neutron Engineering Inc.

2.5” SATA HDD External
Enclosure
17°C
AC 120V/60Hz
USB READ/WRITE

E.U.T :
Temperature :
Test Voltage :
Test Mode :
Freq.
(MHz)
168.01
240.01
344.39
360.01
480.02
960.01

Ant.
H/V
H

Model Name :

SUB2A8

Relative Humidity : 72%

Reading(RA) Corr.Factor(CF) Measured(FS)
(dBuV)
(dB)
(dBuV/m)
26.68
32.21
-5.53

Limits(QP)
(dBuV/m)
30.00

Margin
(dB)
- 3.32

Note

H
H

40.10
35.60

-6.26
-3.10

33.84
32.50

37.00
37.00

-

3.16
4.50

(QP)
(QP)

H
H

35.24
33.10
21.20

-2.74
0.11
9.23

32.50
33.21

37.00
37.00

-

4.50
3.79

(QP)

30.43

37.00

-

6.57

H

Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measure-ment
didn‘t perform。
(3) Measuring frequency range from 30MHz to 1000MHz。
(4) If the peak scan value is under the limit for more than 20dB, the signal will not show in
table。

Report No.: NEI-FCCE-1-E0903103

Page 20 of 22

Neutron Engineering Inc.
5. EUT TEST PHOTO
Conducted Measurement Photos

Report No.: NEI-FCCE-1-E0903103

Page 21 of 22

Neutron Engineering Inc.

Radiated Measurement Photos

Report No.: NEI-FCCE-1-E0903103

Page 22 of 22



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2009:04:10 10:37:38+08:00
Create Date                     : 2009:04:10 10:36:51+08:00
Metadata Date                   : 2009:04:10 10:37:38+08:00
Format                          : application/pdf
Title                           : Microsoft Word - NEI-FCCE-1-E0903103.doc
Creator                         : Administrator
Document ID                     : uuid:2e3fabc3-b5be-4064-b488-105e68068e78
Instance ID                     : uuid:535d39a9-de2d-453e-8af1-4b1031af7174
Page Count                      : 22
Author                          : Administrator
EXIF Metadata provided by EXIF.tools

Navigation menu