Nexus 1500+
®

Next Generation Power Meter for Critical Energy Circuits

Advanced Metering and
Communication

www.electroind.com

• Constant Calibration™ Architecture Provides Highly
Stable Readings, as the Meter Self-calibrates
Every 10 Seconds
• Critical Metering Needs are Met by 0.06% Accuracy in
Energy Metrology
• Color Touchscreen Programmable Display Enhances the
Meter's Functionality
• 6 Available Communication Ports, Including Dual
Ethernet Ports
• Ethernet Ports Offer Secure, Configurable Port
Services Control
• Supported COM Protocols Include Modbus, DNP 3.0,
IEC 61850, and GOOSE Messaging

Superior Recording and Power
Quality Analysis
• Class A IEC 61000-4-30 Power Quality Measurement
• Class A IEC 61000-4-15 Flicker Measurement
• Class A IEC 61000-4-7 Harmonics Measurement
• Supports Customized EN 50160 Power Quality Reporting
• Offers up to 4 GB of Memory for Storage
• Offers 50 MHz Transient Capture Speed
• The Perfect Meter for Co-generation and Independent
Power Providers
• Supports Substation Automation, Grid Monitoring, and
Distribution Substation Reliability Measurements

Electro Industries/GaugeTech™
The Leader in Power Monitoring and Smart Grid Solutions™

Introduction
The Nexus® 1500+ meter is designed to be a primary and testable
revenue meter that additionally provides advanced power quality analysis
functions. It records every aspect of electrical power, including power
quality and transients, and gives you access to this information both in
real time and through reports on the quality of the electrical circuit in
compliance with the IEC 61000-4-30 Class A and EN 50160 international
standards. In this way, the Nexus® 1500+ meter provides you with a
comprehensive picture of your circuits’ power usage and reliability.
The Nexus® 1500+ meter’s capabilities insure that essential data is
captured and stored, so that critical information about important electrical
circuits is not lost. Designed with superior processing power that lets it
measure energy usage precisely, large amounts of memory for recording
events, and advanced power quality reporting compliance, the Nexus®
1500+ meter is the clear choice for your applications where critical metering is an absolute necessity, be it for power utility, industrial, or other
critical metering usage.

Highly Accurate Energy Metrology
The Nexus® 1500+ meter incorporates one of the most advanced
metrologies available for measuring energy. Providing highly accurate
measurements exceeding the ANSI C12.20 (0.2 Class) standard and the
IEC 62053-22 (0.2S Class) standard, the 1500+ provides an Energy
Class accuracy of 0.06%, with typical shipping accuracies of 0.02%.
Additionally, the meter has a highly accurate front panel test pulse that
lets you test on one pulse at low pulse weight, which you can use to
quickly determine accuracy. The meter also features a new precision real
time clock that offers accuracy of 3.5 ppm, or less than 10 seconds per
month drift.
Typical Accuracy over Current Range

Typical 0.02% Accuracy over Full Range
Note that typical accuracy is 0.02%; however, the meter specification should be
consulted for accuracy details.
2

New Constant Calibration™ Architecture Increases
the Stability of Measurement Accuracy
The Nexus® 1500+ meter improves on existing Nexus® architecture
by providing one of the best auto-calibration methods available. Earlier
Nexus® models relied on AccuMeasure™ technology that auto-calibrated
the meter every 12 hours or 5 degree temperature change. Constant
Calibration™ architecture improves significantly on this, by providing
considerably faster, ongoing auto-calibration.
With Constant Calibration™ architecture, the meter utilizes a separate
calibration channel to calibrate the incoming signal in real time every
10 seconds, thereby insuring that the meter experiences minimal drift in
accuracy over time and temperature. With this auto-calibrating circuit,
right out of the box the Nexus® 1500+ meter will stabilize its readings
within 10 seconds. This means you no longer have to wait for the meter to
stabilize in temperature to achieve optimal accuracy. With Constant
Calibration™ architecture, the meter will hold its accuracy throughout
its operation range. Once the meter is tested, it will maintain the precise
accuracy even if the operating conditions are less than ideal.

Typical Meter
Accuracy Charts
Drift over Temperature

Meter Maintains Accuracy over Changing Temperature

Advanced Revenue Meter for
Primary Loads
The Nexus® 1500+ unit is a primary revenue meter designed to be used
for any important applications. In addition to highly accurate energy
measurement, the meter features:
•

Full 4 quadrant metering

•

Energy load profiling: log virtually unlimited historical trending

•

Time of Use perpetual calendar that supports multiple tariffs

•

Transformer and Line Loss compensation: for both iron and
copper and total substation losses

•

CT and PT compensation: correct for errors in current and voltage
transformers

•

Coincidental readings: e.g., PF or VARs at time of Peak Demand,
to identify number of capacitors needed, peak inefficiencies, etc.

•

Load aggregation/universal metering: pulse inputs can be used to
aggregate or accumulate different loads; utility products such as
gas and water can also be accumulated

Test Mode and Energy Presets
The Nexus® 1500+ meter offers a Test Mode for testing meter accuracy.
Test Mode allows the meter to be tested for watt-hour and VAR-hour
accuracy without affecting the stored readings. Using Test Mode, users
can verify the meter’s readings over the lifespan of an installed meter
without having to reset energy or disturb the load profiling and
demand recording.
The Energy Preset feature allows a user to program the energy accumulator values upon exiting Test Mode. This lets the user compensate for
accumulations missed during testing time, or easily swap a new meter for
a meter being replaced.

System Events Logging
The unit provides extensive usage information for detection of
unauthorized access. The unit records:
•

Resets

•

Time changes

•

Programming changes

•

Power up/down

•

Password access changes

•

Change of Firmware

Perpetual Time of Use for Complex Metering
The Nexus® 1500+ meter uses a perpetual Time of Use (TOU) calendar
that only needs to be set up once. The TOU implementation allows the
user to set up multiple tariffs to meet any contractual obligations. It also
allows the user to customize any energy parameter for TOU. The 16
available TOU registers can be configured not only for TOU built-in energy
readings, but also for any stored data from pulses or RTU Master readings
that might need TOU functionality.

3

Class A Power Quality Recorder
EIG’s Nexus® 1500+ meter is one of the industry’s premier fault and
voltage disturbance recorders. This instrument captures and stores a
comprehensive picture of the history of voltage reliability and power
quality events, for detailed and extensive forensic engineering analysis.
The Nexus® 1500+ meter offers a multitude of power quality
functionality that helps the user identify power quality problems, including
harmonics, sags, swells and transients. Power quality features include:
IEC 61000-4-30 Class A Power Quality Meter:

IEC 61000-4-7 Class A Harmonics and
Interharmonics Analysis:
•

View harmonic magnitudes to the 511th order for each voltage
and current channel

•

Harmonic magnitudes and phase angles in real time are resolved
to the 127th order

•

Obtain %THD, TDD, and K-Factor

•

Conduct power quality analysis at the high end of the harmonic
magnitude spectrum

The Nexus® 1500+ meter is a comprehensive Class A power quality
recorder. Designed specifically to meet the rigorous IEC 61000-4-30
Class A standard, it measures and analyzes power quality precisely. All
reporting is available via the EN 50160 reporting format, which provides
a weekly report of power quality indices system-wide. Additionally, the
report can be fully customized to meet the required application or
jurisdictional needs.
•

IEC 61000-4-30 Reporting: Class A Reporting – supports the
most stringent international power quality standards; the Nexus®
1500+ meter offers full reporting of power quality conditions
using the IEC 61000-4-30 Class A methodology

•

Automatic generation of EN 50160 reports and EN 50160 report
customization to support different jurisdictional requirements

Phasor Analysis:
The monitor reads a phase angle analysis between the voltage and current
channels, allowing you to analyze efficiency and system integrity.

High-speed Voltage Reliability Measurements:
Easy-to-Understand Reports Displaying PQ Compliance

The Nexus® 1500+ meter provides industry leading
voltage measurement.

IEC 61000-4-15 Class A Flicker Meter:

4

•

Flicker compliant with the IEC 61000-4-15 Class A standard

•

Operates on both 220 volt/50 Hz and 120 volt/60 Hz throughout
standard test points

•

Real time single cycle RMS measurements

•

Customizable high-speed readings – can be set from 2 to 20
cycles RMS

Set Limit Control:
The Nexus® 1500+ power monitor provides the user with programmable
setpoints. This feature allows a user to configure the meter to be used
as a control device for many applications, such as:
•

Capacitor control

•

Load shedding

•

Automatic transfer schemes

•

Transformer monitoring & control

•

Redundant protection (not designed for primary over-current
protection)

•

Many other control functions

Alarm Notification:
•

The Nexus® 1500+ meter lets you set multiple
programmable limits for any measured value, as well as those
set up in a Boolean logic tree, and limits set up in the IEC 61850
protocol implementation. Users can be notified of alarm
conditions via email.

16 Bit Waveform and Fault Recorder:
•

Record up to 1024 samples per cycle; capture a transient at over
800,000 samples per cycle or at 50 MHz sampling speed

•

Voltage and current recording with pre and post-event analysis

•

Fault recording offers 8 times full scale capture capability

•

16 bit A/D converter provides precise waveform resolution

•

Both hardware and software triggers are available

High-speed Status Input Triggers:
•

Waveforms are recorded at time of status change

•

Input change and waveform recording are time-stamped to a
100 micro second resolution

•

Inputs and waveforms can be displayed together to time breakers
and relays

Subcycle 50 MHz Transient Recorder (V3 Option):
Transients often cause intermittent, expensive periods of downtime. The
subcycle transient recorder allows you to:
•

Record subcycle transients at 50 MHz resolution

•

Monitor switching noise from capacitors, static transfer switches,
SCRs, and other devices that negatively impact power quality

This feature is essential for critical applications such as hospitals,
wafer-fabs plants, data centers and other highly power quality sensitive
applications.
Independent ITIC/CBEMA Log Plotting:
•

Quickly view total surges, sags, and average duration in the
independent ITIC/CBEMA log

•

SEMI F47 graphing for power quality compliance in semiconductor industry

Compatible Waveform Formats
Using Communicator EXT™ software, the meter will provide all
waveform data via COMTRADE and PQDIF compatible formats. This
allows the waveform PQ and fault records to be read by most third-party
waveform analysis software programs.
•

COMTRADE (common format for transient data exchange) is
defined by IEEE Std C37.111

•

PQDIF (power quality data interchange format) is defined by IEEE
Std 1159.3-2003

Record and Analyze Waveform Fault and
Transient Data
5

Multiport Communication
The Nexus® 1500+ meter offers up to 6 simultaneous communication
ports and multiple protocols to meet almost every need.

Industry-Leading DNP 3.0 Level 2 Plus - Complies
with DNP Level 1 and Level 2 Certification
Requirements:

Hardware Features:
Up to 136 measurements (64 Binary Inputs, 8 Binary Counters,
64 Analog Inputs) can be mapped to DNP static points

•

2 optional RS485 ports speaking Modbus and/or DNP 3.0

•

USB front panel port

•

Up to 16 relays and 8 resets can be controlled through DNP

•

ANSI optical front panel port

•

Report-by-exception processing (DNP Events) deadbands
with unsolicited response for serial communication

•

2 separately addressable Ethernet ports

•

•

Optional Fiber or RJ45 media on one Ethernet port

250 available events, in four event types (Binary Input Change,
Frozen Counter, Counter Change, and Analog Change)

Ethernet Communication Port Capabilities:

6

•

8 Built-in Digital High-speed Status Inputs:

•

2 Ethernet ports provide multiple simultaneous communication

•

Inputs automatically sense whether the circuit is externally wetted

•

Each port has separate MAC address and IP address

•

If externally wetted, input up to 150 VDC is accepted

•

Supports Modbus TCP/IP, DNP 3.0 and IEC 61850

•

•

GOOSE messaging protocol supported for IEC 61850

If internally wetted, the meter supplies the necessary voltage for
the contol application

•

Up to 32 Modbus TCP/IP sockets per Ethernet port

•

Highly secure port control to disable unneeded services
and ports

•

Email Function - SMTP email to client on alarm

•

Precise Time Synchcronization - SNTP Time Sync protocol

•

File Transfer Protocol - High-speed file data transfer

VAUX Input:
•

Neutral to ground or aux voltage readings

•

Synchronizing schemes, for example, obtaining the frequency,
magnitude, and phase angle on both sides of a switch or between
generator and bus voltage

Highly Capable Communication Options

Substation Automation

V-Switch™ Key Technology

V-Switch™ key levels V2 and above offer an embedded IEC 61850
Protocol Server for seamless integration with substation automation
applications. Features of the Nexus® 1500+ meter’s IEC 61850
implementation include:

The Nexus® 1500+ meter is equipped with V-Switch™ key upgrade
technology that lets you upgrade meter functionality even after
installation. This means you can purchase what you need now and then
upgrade whenever you need the additional features. Following are the
available V-Switch™ keys:

•

•

The IEC 61850 Protocol Server allows up to 6 simultaneous
MMS clients.

Feature

V1

V2

V3

Either Ethernet port can be configured for IEC 61850 (only one
port at a time can run IEC 61850).

Basic Measurements *

*

*

Memory

512 MB

1 GB

4 GB

•

GOOSE publisher/subscriber functionality is supported.

Sampling Speed

512

1024

Up to 800,000

•

Buffered and unbuffered reports are supported for the following
triggers: general meter interrogation, for example, the report is
generated in response to a query; meter integrity, for example,
the report is generated according to a programmed interval; and
data change, for example, the report is generated due to a change
in the contents of a dataset.

EN61000-4-30
Class A

•

File transfer is supported.

•

Embedded Web Protocol Server support is available for IEC
61850 CID file uploading, IEC 61850 Protocol Server status and
for displaying incoming and outgoing GOOSE messages.

•

•

Multiple Logical Nodes, which map flicker, harmonics, digital
inputs/outputs, limit state, voltage, current, energy and other
data, are supported.

50 MHz Transients

*
*

*

*

IEC 61850 Server

*

*

IEC 61850 GOOSE

*

*

Unique GOOSE Cross Trigger:
•

Fault-based cross trigger of waveform based on GOOSE message

•

Provides system-wide distribution fault analysis on an event

•

Timing better than 200 microseconds is typical

•

Many different circuits can be viewed after an event occured

Waveform capture can be triggered by status input data inside
GOOSE messages. The user can program up to 16 status inputs
that will trigger a waveform capture when the information is
received via a GOOSE message. The status inputs include digital
inputs, limit states, and any other status input supported by the
meter.

Intelligent Substation IEC 61850 Design
Cross Trigger Fault Readings for Simultaneous Station-wide Fault Analysis

7

The Meter of Choice for Critical Energy Measurement

Designed for use between two utility tie points
or for critical SCADA data
8

Expandable Inputs and Outputs to Extend Measurements

Internal I/O

•

8AI2: 8 Analog Inputs, 4-20 mA

•

8AI3: 8 Analog Inputs, 0±5 VDC

•

8AI4: 8 Analog Inputs, 0±20 VDC

485P: Dual RS485/Pulse Output Card

•

Wiring: Common Mode

•

4 KYZ pulses - Solid State

•

Accuracy: 0.25% of Full Scale

•

Pulse width: 5 ms

•

Scaling: Programmable

•

Two RS485 ports

•

Ordering: Up to 4 Analog Input modules

Pulse Outputs:

Relay Outputs:
6RO1: 6 Relay Output Card
•

5 A, 250 VAC/30 VDC

•

Form C (Latching)

Digital Dry Contact Relay Outputs:
•

4RO1: 4 Relay Outputs, 5 A, 250 VAC/30 VDC, Form-C Latching

•

Ordering: 1 module in addition to internal modules

Digital Solid State Pulse Outputs:

Digital Input Status:
16DI1: 16 Status Inputs Card
•

Used for alarm detect or pulse accumulation

•

Up to 150 VDC wetted or non-wetted (24 VDC
internally provided)

Note: The Nexus® 1500+ meter provides one I/O slot for the 485P
(Slot 1), and two I/O slots for the 6RO1 and 16DI1 (Slots 3 and 4).

•

4PO1: 4 Solid State Pulse Outputs, Form A or C KYZ pulses

•

Maximum Pulse Speed: 20 pulses per second

•

Ordering: Up to 4 Digital Solid State Output modules

I/O Module Accessories (Required):
•

PSIO: Power supply required
when using an external
I/O module. The Nexus®
1500+ meter does not have
internal power for external
I/O modules.

•

MBIO: Mounting bracket for
external I/O modules. Must
be ordered with external I/O
module.

External I/O
Analog Outputs:
•

1mAON4/1mAON8: 4 or 8 Analog Outputs, 0-1 mA,
self-powered, scalable, bidirectional

•

20mAON4/20mAON8: 4 or 8 Analog Outputs, 4-20 mA,
self-powered, scalable

•

Wiring: Common Mode

•

Accuracy: 0.1% of Full Scale

•

Calibration: Self-calibrating

•

Scaling: Programmable

•

Ordering: Up to 4 Analog Output modules

Analog Inputs:
•

8AI1: 8 Analog Inputs, 0±1 mA

Secure Communication

Expandable
External
I/O Modules

The Nexus® 1500+ meter offers 9
levels of password security to protect
the meter from unauthorized use. Each
level can be configured to enable specific capabilities, so that a Utility can
control access to functions according
to the type of user. For example, one
user level is able to create and change
TOU calendars, while a different user
level is able to read TOU data, but not
change anything.
9

Vibrant LCD Touch Screen Display
The Nexus® 1500+ meter features an LCD color display with touch
screen capability. The display uses bright TFT glass with a high temperature and long life LED backlight. LED is superior to CCFL solutions due to
better temperature and half-life specifications. Screen displays include:
•

Real-time viewing (voltage,
current, power, demand)

•

Harmonic spectrum
analysis and waveforms

•

Accumulated energy and
time of use readings

•

Real time trending

•

Log status

•

Flicker readings

•

Configuration settings

•

Alarms

•

Multi-language Support

•

Phasor Analysis

Vivid Color Display

Wiring Diagrams
A B C N

*

A B C N

*

CT
Shorting
Block

Va
Vb

Earth
Ground

CTs

N/U

CT
Shorting
Block

Vn

Vc
Vn
Vaux

Vaux

PTs

N/U

Vb

Earth
Ground

CTs

Vc

Va

Vn

Vn

Vc

Vc

Vb

Vb

Va

Va

Earth Ground

A B C N

4-Wire Wye, 3 Element with 4 CTs and 3 PTs
*Note: Optional CT for Current Measurement Only

A B C N

A B C

CT
Shorting
Block

CT
Shorting
Block
Va

Earth
Ground

CTs

4-Wire Wye, 3 Element with 4 CTs and no PTs
*Note: Optional CT for Current Measurement Only

A B C N

N/U

Vb
Vc
Vn

Va

Earth
Ground

CTs

Vc
Vn

Vaux

PTs

N/U

Vb

Vaux

Vc

Vc

Vn

Vb

Va

Va

Earth Ground

10

A B C N

4-Wire Wye, 2.5 Element, 3 CTs and 2 PTs

A B C

3-Wire, 2 Element Delta Direct with 2 CTs

Dimensional Drawings

10.74”
[27.28cm]

1.87”
[4.75cm]

7.6”
[19.30cm]

5.04”
[12.80cm]
5.73”
[14.55cm]

4.44”
[11.28cm]

5.94” [15.09cm]
4.44” [11.28cm]

6.96” [17.68cm]

6.74” [17.12cm]

Front

Side

Back

Specifications
Voltage Input Range:

Accuracy Rating:

•

(5-347)VAC, Line to Neutral

•

Energy measurement accuracy at 0.06%

•

ANSI C12.1 (Code for Electricity Metering)

•

(10-600)VAC, Line to Line

•

Full accuracy specifications available in
Nexus® 1500+ meter User Manual

•

ANSI C62.41 (Burst)

•

ANSI/IEEE C37.90.1 – Surge Withstand

•

FCC Part 15, Subpart B, Class A

•

IEC 61000-4-2 – ESD

•

IEC 61000-4-3 – Radiated Immunity

•

IEC 61000-4-4 – Fast Transient

•

IEC 61000-4-5 – Surge Immunity

•

IEC 61000-4-6 - Conducted Immunity

•

IEC 61000-4-7 – Harmonics

•

IEC 61000-4-15 – Flicker Meter

•

IEC 61000-4-30 – Class A

•

IEC 62052-11 - General Requirements
IEC/CISPR 14-1 - Continuous EM Disturbance

Voltage Input Withstand Capability:
•

Voltage Inputs isolated to 2500 VAC

•

Current Input Range:

Time clock: 3.5 ppm for -40 to +85 °C - less
than 10 seconds drift per month on crystal
sync; 2.0 ppm Typical from 0 - +40 °C - less
than 6 seconds per month drift

•

Programmable to any CT ratio

•

Class 2: Nominal 1 A, with 2 times over range

•

Class 2: fault current recording to +/- 16 A
peak

•

1 Second - Revenue accurate readings

•

1 Cycle - Faster updated readings

•

Class 20: Nominal 5 A, with 4 times over range

•

•

Class 20: fault current recording to +/- 80 A
peak

Customizable high-speed readings - from 2 to
20 cycles RMS

Control Power Requirements:

Current Input Withstand Capability
(at 23°C):

Update Time:

•

D2 Option: (100–240)VAC @50/60 Hz or
(100-240)VDC

(0.2S Class) Accuracy

•

100 A for 10 seconds

•

115AC Option: (100-240)VAC @50/60 Hz

•

•

300 A for 3 seconds

•

D Option: (18-60)VDC (24-48 VDC Systems)

•

CE Marked

•

500 A for 1 second

•

Burden: 25 VA Max

•

UL and cUL Listed

Burden:

Frequency Range:

External I/O Modules

•

•

•

1mAON4: 4 Analog Outputs, 0±1 mA

Communication:

•

1mAON8: 8 Analog Outputs, 0±1 mA

•

Programmable parity and stop bits

•

20mAON4: 4 Analog Outputs, 4-20 mA

•

Communication protocols: Modbus TCP/IP,
ASCII/RTU; DNP 3.0; IEC 61850 (V2 and above)

•

20mAON8: 8 Analog Outputs, 4-20 mA

Temperature Rating:

•

8AI1: 8 Analog Inputs, 0±1 mA

•

ANSI optical port

•

Operating temperature: (-20 to +70)°C

•

8AI2: 8 Analog Inputs, 4-20 mA

•

USB 1.1/2.0 Virtual COM port

•

Storage temperature: (-30 to +80)°C

•

8AI3: 8 Analog Inputs, 0±5 VDC

•

RJ45 Ethernet port 10/100BaseT

•

Humidity: Up to 95% RH non-condensing

•

8AI4: 8 Analog Inputs, 0±10 VDC

•

Optional 2nd Ethernet port - RJ45 or Fiber Optic

Sensing Method:

•

4RO1: 4 Relay Outputs

•

2 RS485 ports (optional)

•

Up to 1024 samples per cycle (programmable)

•

4PO1: 4 Solid State Pulse Outputs

Shipping:

•

16 Bit A/D resolution – multiple converters

•

•

Total shipping weight: approx. 6.5 lbs (2.9 kgs)

PSIO: Power Supply for I/O modules (must be
ordered with external I/O module)

•

Constant Calibration™ technology

•

•

•

True RMS

Shipping container dimensions: 16" x 15.5" x
11.5" (40.64 am x 39.37 cm x 29.21 cm)

MBIO: I/O mounting bracket (must be ordered
with external I/O module)

•

Transient at 50 million samples per second

•

Voltage Inputs: 0.072 VA/phase max at 600
volts, 0.003 VA/phase max at 120 volts
Current Inputs: 0.008 VA per phase max at 20 A

Isolation:
•

All inputs to outputs are isolated to 2500 VAC

45 Hz–69.9 Hz

Compliance:
•

ANSI C12.20 (0.2 Class) and IEC 62053-22

Note: Please see product User Manual for
comprehensive specifications.

11

To order a Nexus® 1500+ meter:
•

•

Fill out the options you want in the order chart shown below:
list accessories separately.

•

EIG can also provide current and potential transformers.

•

Email or fax order information and quantity to the email address or fax
number listed below, or call the phone number listed below to place
your order.

Specify Communicator EXT™ 4.0 software.

Ordering Information
Nexus®
Base Meter
-

Option
Numbers:
Example:

Control
Power

Nexus 1500+
Nexus®
1500+ Meter

-

Frequency
Range
-

D2

-

Current
Class
-

60

-

Virtual
Switch
-

20

-

Communication
Expansion/Slot 1
-

V2

I/O
Slot 2

-

-

485P

I/O
Slot 3
-

-

NTRJ

I/O
Slot 4
-

-

6RO1

-

6RO1

115AC
(100-240)VAC
@50/60 Hz

60
60 Hz

20
20 A

V1
Standard
Nexus® 1500+ Meter
512 MB memory / 512 s/c

X
No Option

X
No Option

X
No Option

X
No Option

D2
Universal
(100-240)VAC
@50/60 Hz
or (100-240)VDC

50
50 Hz

2
2A

V2
V1 + 1 GB memory /
1024 s/c
IEC 61850

485P
2 RS485 and
4 Pulse Outputs

NTRJ
Second RJ45
Network Card

6RO1
6 Relay
Outputs

6RO1
6 Relay
Outputs

NTFO
Second Fiber
Network Card
(ST terminated)

16DI1
16 Status
Inputs

16DI1
16 Status
Inputs

D
(18-60)VDC

V3
V2 + 4 GB memory /
50 MHz
Transient Recording

Accessory Options
Software
COMEXT4P1Y

Communicator EXT™ 4.0
Software for Windows
Single-Computer License (One
Site)

I/O Modules
1mAON4
1mAON8
20mAON4
20mAON8
8AI1
8AI2
8AI3
8AI4
4RO1
4PO1

4 Analog Outputs, 0±1 mA
8 Analog Outputs, 0±1 mA
4 Analog Outputs, 4-20 mA
8 Analog Outputs, 4-20 mA
8 Analog Inputs, 0±1 mA
8 Analog Inputs, 4-20 mA
8 Analog Inputs, 0±5 VDC
8 Analog Inputs, 0±10 VDC
4 Relay Outputs
4 Solid State Pulse Outputs

*PSIO

Power Supply for
External I/O Modules

*MBIO

I/O Mounting Bracket

* Must be ordered with an external
I/O module.

About Electro Industries: Electro Industries/GaugeTech is one of the oldest and largest manufacturers of microprocessor-based digital power meters in the
United States. EIG's success is attributable to our willingness to support our users with on-staff technical expertise. Contact us and we will assist you in solving your
complex metering applications.

Nexus® 1500+ web page:
http://electroind.com/product-info/nexus-1500_plus-nextgeneration-power-quality-revenue-meter/

Electro Industries/GaugeTech™

1800 Shames Drive, Westbury, NY 11590 1-877-EIMETER (1-877-346-3837)

The Leader in Power Monitoring and Smart Grid Solutions™ Tel: 516-334-0870 Fax: 516-338-4741 Email: sales@electroind.com
www.electroind.com
E154718 012016 V.1.05



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2016:01:20 16:13:21-05:00
Metadata Date                   : 2016:01:20 16:14:12-05:00
Modify Date                     : 2016:01:20 16:14:12-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:58dfff98-573f-4a76-8d98-ca609cf5df49
Original Document ID            : adobe:docid:indd:16dc73aa-227d-11e0-a17f-bf3b56d83edc
Document ID                     : xmp.id:499E5F95BABFE511A8ABE4BDA445C314
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:489E5F95BABFE511A8ABE4BDA445C314
Derived From Document ID        : xmp.did:93D352AA01BEE511B45A82F85738B188
Derived From Original Document ID: adobe:docid:indd:16dc73aa-227d-11e0-a17f-bf3b56d83edc
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:01:20 16:13:21-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 12
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu