RG 68X576703_RevA_HIRES_10_11 Orion Star A213 A223 A323
User Manual: Pdf Orion Star-A213-A223-A323
Open the PDF directly: View PDF
.
Page Count: 52
| Download | |
| Open PDF In Browser | View PDF |
Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meters Reference Guide For Sales & Service Contact 2650 E. 40th Ave. • Denver, CO 80205 Phone 303-320-4764 • Fax 303-322-7242 1-800-833-7958 www.geotechenv.com Ross and the COIL trade dress are trademarks of Thermo Fisher Scientific, Inc. and its subsidiaries. AQUAfast, AQUASensors, BOD AutoEZ, ionplus, KNIpHE, LogR, No Cal, ORION, perpHect, PerpHecT, pHISA, pHuture, Pure Water, Sage, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS, and TURBO2 are registered trademarks of Thermo Fisher Scientific, Inc. and its subsidiaries. A+, All in One, Aplus, AUTO-BAR, AUTO-CAL, Auto-ID, AUTO-READ, AUTO-STIR, Auto-Test, AutoTration, CISA, digital LogR, DuraProbe, EZ Startup, ISEasy, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, Optimum Results, Orion Dual Star, Orion Star, SAOB, SMART AVERAGING, SMART STABILITY, Star LogR, Star Navigator 21, Stat Face, Triode are trademarks of Thermo Fisher Scientific, Inc. and its subsidiaries. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher Scientific, Inc. and its subsidiaries. © 2011 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific, Inc. and its subsidiaries. The specifications, descriptions, drawings, ordering information and part numbers within this document are subject to change without notice. This publication supersedes all previous publications on this subject. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meters Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Chapter 2 Meter Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Meter Connections and Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Electrodes and Other Connections . . . . . . . . . . . . . . . . . . . .4 Connecting Electrode Arm to the Benchtop Meter . . . . . . . .5 Meter Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Meter Keypad. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Meter Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chapter 3 Meter Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Navigating the Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Setup Menu Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 DO/RDO Channel Menu . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Settings Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 View Log Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Diagnostics Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Chapter 4 RDO/DO Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Air Dissolved Oxygen Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Dissolved Oxygen Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual Dissolved Oxygen Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Set Zero Dissolved Oxygen Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 16 17 18 Chapter 5 Temperature Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Chapter 6 Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Chapter 7 Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Saving the Current Meter Settings as a New Method. . . . . . . . . . . . . . . . . . . . . 23 Loading an Existing Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Editing, Copying or Deleting an Existing Method. . . . . . . . . . . . . . . . . . . . . . . . . 24 Chapter 8 Data Storage and Retrieval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Data Storage Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Read Type Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Computer and Printer Export Settings . . . . . . . . . . . . . . . . .26 Data Log Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Viewing the Calibration Log and Data Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Viewing the Calibration Log . . . . . . . . . . . . . . . . . . . . . . . . .27 Viewing the Data Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Exporting the Data Log to a Computer or Printer . . . . . . . . . . . . . . . . . . . . . . . . . 28 Clearing the Data Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Interfacing a Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Interfacing a Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Chapter 9 Customer Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Meter Errors and Recommended Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Meter Self Test and Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Meter Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Electrode Stability Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Meter Factory Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Meter User Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 About Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Warranty and Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Chapter 10 Meter Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Notice of Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WEEE Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Declaration of Conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix 1 39 39 40 41 Advanced Meter Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Dissolved Oxygen Barometric Pressure Compensation . . . . . . . . . . . . . . . . . . 45 Dissolved Oxygen Salinity Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 This page intentionally left blank. Chapter 1 Introduction Thank you for your purchase of the Orion Star A213 benchtop RDO/DO meter, Star A223 portable RDO/DO meter or Star A323 portable RDO/DO meter. These meters are capable of measuring dissolved oxygen and temperature in °C or °F. The Orion Star A213 benchtop RDO/DO meters feature t %JTTPMWFEPYZHFOSBOHFPGUPNH-PSUPTBUVSBUJPOVTJOHBO3%0PQUJDBMEJTTPMWFE PYZHFOQSPCFXJUIBSFTPMVUJPOPGPSNH-BOEPSTBUVSBUJPO t %JTTPMWFEPYZHFOSBOHFPGUPNH-PSUPTBUVSBUJPOVTJOHBQPMBSPHSBQIJDEJTTPMWFE PYZHFOQSPCFXJUIBSFTPMVUJPOPGPSNH-BOEPSTBUVSBUJPO t "6503&"% DPOUJOVPVT XJUIIPMEPQUJPO BOEUJNFENFBTVSFNFOUNPEFT t QPJOUEBUBMPH t NBOVBM SFBEZ "6503&"% BOEUJNFEEBUBMPHHJOHGVODUJPOT t *1SBUFEEVTUBOETQMBTISFTJTUBOUIPVTJOH The Orion Star A223 portable RDO/DO meters feature t %JTTPMWFEPYZHFOSBOHFPGUPNH-PSUPTBUVSBUJPOVTJOHBO3%0PQUJDBMEJTTPMWFE PYZHFOQSPCFXJUIBSFTPMVUJPOPGPSNH-BOEPSTBUVSBUJPO t %JTTPMWFEPYZHFOSBOHFPGUPNH-PSUPTBUVSBUJPOVTJOHBQPMBSPHSBQIJDEJTTPMWFE PYZHFOQSPCFXJUIBSFTPMVUJPOPGPSNH-BOEPSTBUVSBUJPO t "6503&"%BOEDPOUJOVPVT XJUIIPMEPQUJPO NFBTVSFNFOUNPEFT t QPJOUEBUBMPH t NBOVBMBOEBVUPNBUJDXJUI"6503&"%EBUBMPHHJOHGVODUJPOT t *1SBUFEEVTUQSPPGBOEXBUFSQSPPGIPVTJOH The Orion Star A323 portable RDO/DO meters feature t %JTTPMWFEPYZHFOSBOHFPGUPNH-PSUPTBUVSBUJPOVTJOHBO3%0PQUJDBMEJTTPMWFE PYZHFOQSPCFXJUIBSFTPMVUJPOPGPSNH-BOEPSTBUVSBUJPO t %JTTPMWFEPYZHFOSBOHFPGUPNH-PSUPTBUVSBUJPOVTJOHBQPMBSPHSBQIJDEJTTPMWFE PYZHFOQSPCFXJUIBSFTPMVUJPOPGPSNH-BOEPSTBUVSBUJPO t "6503&"% DPOUJOVPVT XJUIIPMEPQUJPO BOEUJNFENFBTVSFNFOUNPEFT t QPJOUEBUBMPH t NBOVBM SFBEZ "6503&"% BOEUJNFEEBUBMPHHJOHGVODUJPOT t *1SBUFEEVTUQSPPGBOEXBUFSQSPPGIPVTJOH Please read this reference guide thoroughly. Any use outside of these instructions may invalidate your warranty and cause permanent damage to the meter. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 1 This page intentionally left blank. 2 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 2 Meter Overview Meter Connections and Inputs Power Source 1PXFSBEBQUFS JODMVEFEXJUICFODIUPQNFUFST TPMETFQBSBUFMZGPSQPSUBCMFNFUFST a. Select the appropriate wall socket plug plate. b. Slide off the clear plastic cover from the plug plate. c. Slide the plug plate into the groove on the back of the power adapter. d. Connect the power adapter to the meter and power outlet. #BUUFSJFT JODMVEFEXJUIQPSUBCMFNFUFST TPMETFQBSBUFMZGPSCFODIUPQNFUFST a. Select four AA alkaline batteries. b. Confirm that the meter is powered off. c. Remove the battery compartment cover. i. Benchtop meters – push down on the battery compartment tab and lift the battery cover up. ii. Portable meters – loosen the screws holding the battery cover, release the top portion of the CBUUFSZDPWFSGSPNUIFNFUFS VTFBDPJOPSZPVSmOHFS BOESFMFBTFUIFCPUUPNQPSUJPOPGUIF battery cover. d. Orientate the batteries as shown in the battery compartment housing and insert batteries. e. Replace the battery compartment cover. For portable meters – replace the screws. Orion Star A Series Benchtop Orion Star A Series Portable Remove screws Push down on tab and lift the battery cover Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 3 Electrodes and Other Connections 1. Prepare the RDO optical dissolved oxygen probe or polarographic dissolved oxygen probe and any other applicable electrodes according to the directions in the electrode user guide. 2. Connect the appropriate items as labeled on the meter and as shown in the figure below: Ground DO/RDO Power Ref. ATC/CON BNC USB Stirrer RS232 Star A213 Meter Back Panel DO/ RDO ATC/ COND REF USB BNC POWER RS232 Star A223 and Star A323 Meter Back Panel t (SPVOEo*OQVUGPSBHSPVOEXJSFXJUIBTUBOEBSEQJOUJQDPOOFDUPSOrion Star A213 benchtop meters only. t %03%0o*OQVUGPS3%0PQUJDBMEJTTPMWFEPYZHFOQSPCFPSQPMBSPHSBQIJDEJTTPMWFEPYZHFOQSPCFXJUI QJO.JOJ%*/DPOOFDUPS t 1PXFSo*OQVUGPSUIFQPXFSBEBQUFS t 4UJSSFSo*OQVUGPSUIFTUJSSFSQSPCF $BU/POrion Star A213 benchtop meters only. t 64#o*OQVUGPSUIF64#DBCMF VTFEUPDPOOFDUUIFNFUFSUPBQSJOUFSPSDPNQVUFS t 34o*OQVUGPSUIF34DBCMF VTFEUPDPOOFDUUIFNFUFSUPBQSJOUFSPSDPNQVUFS 4 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Connecting Electrode Arm to an Orion Star A Series Benchtop Meter Orion Star A series benchtop meters include an electrode arm that can be attached to either side of the meter. 6OQBDLUIFFMFDUSPEFBSNBOECBTF 2. Choose the side of the meter to attach the arm. 6TFBDMFBOTVSGBDFBOEUVSOUIFNFUFSPWFS 3FMFBTFUIFFYJTUJOHTDSFXGSPNUIFCBDLPGUIFNFUFS "MJHOUIFFMFDUSPEFBSNCBTFXJUIUIFDJSDMFTBUUIFCPUUPNPGUIFNFUFS5IFNFUBMQPTUPOUIFFMFDUSPEFBSNCBTF should be on the same side as the meter display. 5BLFUIFTDSFXUIBUXBTSFNPWFEBOEVTFJUUPTFDVSFUIFFMFDUSPEFBSNCBTFUPUIFNFUFS 5VSOUIFNFUFSPWFS 8. Place the hole at the bottom of the electrode arm onto the metal post on the electrode arm base. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 5 Meter Display Display Icon Description Shown when the meter is running on AC power. Shown when the meter has batteries installed. *OEJDBUFTEBUBJTCFJOHTFOUUPBDPNQVUFSPSQSJOUFS *OEJDBUFTEBUBJTCFJOHTFOUUPUIFEBUBMPH Shown when an alarm is set and the alarm value is reached. *OEJDBUFTUIFNFUFSJTTFUUPCFJOUFSGBDFEXJUIBQSJOUFSPSDPNQVUFSWJBUIF34QPSU *OEJDBUFTUIFNFUFSJTTFUUPCFJOUFSGBDFEXJUIBQSJOUFSPSDPNQVUFSWJBUIF64#QPSU Displays the time and date entered in the setup menu. C 25.0˚ATC HOLD Displays the current temperature based on the temperature probe reading or entered temperature value. Shows the PSJHJOPGUIFUFNQFSBUVSFBT."/ FOUFSFEUFNQFSBUVSF PS"5$ UFNQFSBUVSFQSPCF Shown when is pressed and the displayed measurement is frozen. *OEJDBUFTBDBMJCSBUJPOXBTTVDDFTTGVMMZDPNQMFUFE*DPOXJMMCMJOLXIFOUIFDBMJCSBUJPOBMBSNJTTFUBOEUIF alarm value is reached. M *OEJDBUFTBNFUIPEJTJOVTFBOEUIFOVNCFSPGUIFNFUIPECFJOHVTFE DO *OEJDBUFTUIFUZQFPGNFBTVSFNFOUBOETIPXTUIFUZQFPG%0QSPCFDPOOFDUFEUPUIFNFUFSBT RDO 3%0PQUJDBM PSDO QPMBSPHSBQIJD 100 ready Specifies the stability of the electrode as stabilizing or ready. 4IPXOXIFOUIFNFUFSJTJO"6503&"%NPEF5IF icon will blink while the reading is stabilizing and stop blinking when the reading is stable and the measurement is locked on the display. 98.5 %sat Auto Baro Press : 757.3 Salt: 0.0 %JTQMBZTUIFNFBTVSFNFOUWBMVFCBTFEPOUIFMBTUTBWFEDBMJCSBUJPOBOEDVSSFOUFMFDUSPEFSFBEJOH6OJUTBSF shown to the right of the value. Shows the barometric pressure measured by the meter (Auto) or entered by operator (Man.) and used to correct dissolved oxygen measurements. Displays the salinity correction factor used to correct dissolved oxygen measurements. 4IPXTUIFPQFSBUPSBTTJHOFETBNQMF*%OVNCFSOrion Star A213 and Star A323 meters only. 4IPXTUIFPQFSBUPSBTTJHOFEVTFS*%OVNCFSOrion Star A213 and Star A323 meters only. 6 cal Displays the action that will be performed when f1 is pressed. sample ID Displays the action that will be performed when f2 is pressed. channel Displays the action that will be performed when f3 is pressed. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Meter Keypad measure (esc) Orion Star A200 and A300 Series Portable Keypad Orion Star A200 Series Benchtop Keypad setup hold mode log/print Press the f1, f2 and f3 function keys to perform the action shown above each key on the display. Press to turn the meter on. When the meter is on, press and quickly release to turn the display backlight on or off or hold down to turn the meter off. *OUIFNFBTVSFNFOUNPEF QSFTTUPUBLFBNFBTVSFNFOU *OUIFTFUVQ DBMJCSBUJPOBOEPUIFSNFOVT QSFTTUPFTDBQFUIFDVSSFOUNFOVBOESFUVSOUPUIF measurement mode. *OUIFNFBTVSFNFOUNPEF QSFTTUPFOUFSUIFTFUVQNFOV *OUIFTFUVQ DBMJCSBUJPOBOEPUIFSNFOVT QSFTTUPTDSPMMVQUISPVHIBMJTUPGPQUJPOT *OUIFDPOUJOVPVTNFBTVSFNFOUNPEF QSFTTUPIPME GSFF[F UIFEJTQMBZFENFBTVSFNFOUBOEQSFTT BHBJOUPSFMFBTF VOGSFF[F UIFNFBTVSFNFOU *OUIFTFUVQ DBMJCSBUJPOBOEPUIFSNFOVT QSFTTUPTDSPMMMFGUUISPVHIBMJTUPGPQUJPOT *OUIFNFBTVSFNFOUNPEF QSFTTUPDIBOHFUIFEJTQMBZFENFBTVSFNFOUNPEF0QUJPOTBSFTBU EJTTPMWFEPYZHFOJOQFSDFOUTBUVSBUJPO NH- EJTTPMWFEPYZHFOJONJMMJHSBNTQFSMJUFS PS ¡$ QSPCFNFNCSBOFUFNQFSBUVSF *OUIFTFUVQ DBMJCSBUJPOBOEPUIFSNFOVT QSFTTUPTDSPMMSJHIUUISPVHIBMJTUPGPQUJPOT *OUIFNFBTVSFNFOUNPEF QSFTTUPMPHPSQSJOUBNFBTVSFNFOU *OUIFTFUVQ DBMJCSBUJPOBOEPUIFSNFOVT QSFTTUPTDSPMMEPXOUISPVHIBMJTUPGPQUJPOT Press to view the data log and calibration log. Orion Star A213 benchtop meters only. Press to start or stop the stirrer probe. Orion Star A213 benchtop meters only. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 7 1. Press to power the meter on. When the meter is on, press and quickly release on or off or press and hold 2. Press to turn the backlight for about three seconds to power the meter off. to exit any meter function and return to the measurement mode. 3. The f1, f2, and f3GVODUJPOLFZTQFSGPSNBWBSJFUZPGNFUFSPQFSBUJPOT5IFNFOVTQFDJmDPQFSBUJPOJTTIPXO above each key on the display. For example, press f1 in the measurement mode to start a calibration. , 5IF , or LFZTBSFVTFEBTOBWJHBUJPOLFZT VQ SJHIU EPXO MFGU XIFOTFMFDUJOHGSPNBmYFE MJTUPSHSJEPGNFUFSPQUJPOT*OUIFNFBTVSFNFOUNPEF UIFTFLFZTBSFVTFEUPBDDFTTUIFTFUVQNFOV DIBOHF UIFNFBTVSFNFOUNPEF NBOVBMMZMPHPSQSJOUBNFBTVSFNFOUBOEIPME GSFF[F BEJTQMBZFENFBTVSFNFOUJOUIF continuous measurement mode. *OUIFDPOUJOVPVTNFBTVSFNFOUNPEF XIFO JTQSFTTFEBOEUIFNFBTVSFNFOUJTCFJOHIFME GSP[FO POMZUIF LFZXJMMCFGVODUJPOBMVOUJMUIFNFBTVSFNFOUJTSFMFBTFE VOGSP[FO 1SFTT UPUVSOPOPSPGGUIFTUJSSFSQSPCF $BU/P Orion Star A213 benchtop meters only. 1SFTT to access the calibration log and data log. Orion Star A213 benchtop meters only. Meter Maintenance 'PSSPVUJOFNFUFSNBJOUFOBODF EVTUBOEXJQFUIFNFUFSXJUIBEBNQDMPUI*GOFDFTTBSZ XBSNXBUFSPSBNJME XBUFSCBTFEEFUFSHFOUDBOCFVTFE.FUFSNBJOUFOBODFDBOCFQFSGPSNFEPOBEBJMZ XFFLMZPSNPOUIMZCBTJT BT SFRVJSFECZUIFFOWJSPONFOUJOXIJDIUIFNFUFSJTPQFSBUFE*NNFEJBUFMZSFNPWFBOZTQJMMFETVCTUBODFGSPNUIF meter using the proper cleaning procedure for the type of spill. 8 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 3 Meter Setup Navigating the Setup Menu *OUIFNFBTVSFNFOUNPEF QSFTT to enter the main setup menu. 2. Press , , or to scroll through the main setup menu options. Press f3 (select) to select a main setup menu option. 3. Press or to scroll through setup submenu options. Press f3 (select) to select a setup submenu option. 1FSGPSNUIFBQQSPQSJBUFBDUJPOTUPTFUUIFEFTJSFEQBSBNFUFSJOUIFTFUVQTVCNFOVT a. To select a value from a list of options, press f3 (select) to set the value. b. To enter a numeric value, use the numeric entry screen. or to highlight the desired value and press i. Select the value to be entered by pressing f3 (select) or f3 (edit). The numeric entry screen will popup on the display. ii. Press , , or to highlight a number, decimal place or negative sign; press f3 (enter) to select the highlighted item and repeat until the desired value is shown on the top of the numeric entry screen. iii. Press f2 (done) to save the value and exit the numeric entry screen. 1SFTTf1 (back) and then to return to the measurement mode at any time. Setup Menu Overview DO/RDO Channel Settings Log View Diagnostics Method (Star A213 and Star A323 meters only) t&YQPSU%BUB t%BUB-PH t%BUF5JNF t-BOHVBHF t,FZ1SFTT#FFQ t"MBSN#FFQ t4UJSSFS(Star A213 meters only) t$POUSBTU t"VUP4IVU0GG t6TFS*%(Star A213 and Star A323 meters only) t4BNQMF*%(Star A213 and Star A323 meters only) t%BUB-PH t$BMJCSBUJPO-PH t'BDUPSZ3FTFU t6TFS3FTFU t4FMG5FTU t4UBCJMJUZ5FTU t"CPVU.FUFS Mode & Settings t.FBTVSF.PEF t.FBTVSF6OJU t3FTPMVUJPO t3FBE5ZQF t#BSP1SFTT t4BMJOJUZ$PSSFDU t4UBCJMJUZ(Star A213 and Star A323 meters only) t"WFSBHJOH(Star A213 and Star A323 meters only) t-JNJU"MBSN t$BM%VF"MBSN t3%0$BQ-JGF(RDO only) Temperature t.BOVBM5FNQ7BMVF t5FNQFSBUVSF6OJU t5FNQFSBUVSFCalibration Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 9 DO/RDO Channel Menu The DO/RDO Channel setup menu is used to review and change parameters relating to dissolved oxygen measurements and calibrations. Main Setup Menu 2nd Level 3rd Level Menu Options Menu allows the current meter settings to be saved as a new method, an existing method to be run on the meter, or an existing method to be viewed, edited, copied, deleted or printed. Star A213 and Star A323 meters only. DO/RDO Channel Method List of Methods Mode and Settings Measure Mode .FBTVSF6OJU 3FTPMVUJPO NH-NPEF 3FTPMVUJPO TBUNPEF Menu Description t%0 t3%0 t"VUP Menu used to select the type of DO probe used. The meter accepts and automatically recognizes Orion RDO optical DO probes and Orion QPMBSPHSBQIJD%0QSPCFT6TFUIJTNFOVJGBEJGGFSFOUQSPCFJTVTFEPS the probe type needs to be verified. tNHtTBU Menu used to select the displayed measurement units. t1 Decimal Place t2 Decimal Places t1 Decimal Place 1 t2 Decimal Places Menu used to select the resolution for the displayed measurement values. Menu used to select the resolution for the displayed measurement values. Menu used to select how the meter will take measurements. Auto o1SFTT to take a measurement. When the measurement is stable, it is locked on the display until is pressed again. t"VUP t$POUJOVPVT Read Type t5JNFE (Star A213 and Star A323 meters only) Continuous – The measurement is constantly updated on the display and stabilizing or ready is shown to indicate the measurement stability. Timed – Measurements are taken at a set time interval. To enter the time interval, highlight t5JNFEpress to highlight the IPVST )) NJOVUFT .. PSTFDPOET 44 QSFTTf3 (edit) and use the numeric entry screen to change the values. Baro Press Salinity Correct tAutomatic tManual tManual t4NBSU4UBCJMJUZ t'BTU Stability t.FEJVN t4MPX 10 Menu used to select automatic or manual barometric pressure DPNQFOTBUJPOGPSEJTTPMWFEPYZHFONFBTVSFNFOUT6TFUIFOVNFSJD entry screen to enter a manual value. Menu used to set manual salinity correction for dissolved oxygen NFBTVSFNFOUT6TFUIFOVNFSJDFOUSZTDSFFOUPFOUFSBNBOVBMWBMVF Menu used to select how the stability of the displayed measurement values is indicated. Smart Stability automatically compensates for measurement conditions and optimizes the meter response time. Star A213 and Star A323 meters only. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide DO/RDO Channel Menu (cont.) Main Setup Menu 2nd Level 3rd Level Averaging Mode and Settings DPOU Menu Options t0GG t"VUPNBUJD4NBSU t-JNJU"MBSN On Off t"MBSN4FUUJOHT -JNJU"MBSN -PX )JHI )JHI-PX t)JHI-JNJU t-PX-JNJU Menu Description Menu used to turn the averaging function on or off. Automatic Smart automatically compensates for measurement conditions and optimizes the meter response time. Star A213 and Star A323 meters only. Menu used to turn the limit alarm on or off and to set the limit alarm parameters. The limit alarm is triggered if the measurement goes above a high value and/or below a low value set by the operator. Press or to change the setting on each line, press or to select another line and use the numeric entry screen to enter limit values. Star A213 and Star A323 meters only. Menu used to turn the calibration due alarm on or off and to set the calibration due alarm time. The calibration due alarm is triggered if a t$BM%VF"MBSN On Off Cal Due Alarm t$BM%VF-JNJU DO/RDO Channel (cont.) set amount of time has passed without a calibration being performed. Press or to change the setting on the top line, press or to select another line and use the numeric entry screen to enter the calibration due value in hours. Star A213 and Star A323 meters only. Star A223 meters have the cal due option with a fixed value of 12 hours. 3%0$BQ-JGF 3%0NPEF Temperature .BOVBM5FNQ7BMVF 5FNQFSBUVSF6OJU Temperature Calibration 5FNQFSBUVSF*OQVU $BQ-JGF 4FSJBM/VNCFS Menu used to display the RDO optical cap life as days remaining and the RDO optical cap serial number. Default value or last entered value Menu used to set the temperature value that will be used for all NFBTVSFNFOUTBOEDBMJCSBUJPOT6TFUIFOVNFSJDFOUSZTDSFFOUPFOUFS the temperature. t$FMTJVT t'BISFOIFJU Menu used to select the temperature units. t4PMVUJPO5FNQFSBUVSF t.FNCSBOF Temperature t4PM.FN Temperature Menu allows the solution temperature measured by a DO probe, membrane temperature measured by a DO probe or a combination of these to be adjusted by the operator. t%01SPCF t.BOVBM Menu used to select the source of the temperature measurement. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 11 Settings Menu The Settings setup menu is used to review and change parameters relating to the general operation of the meter. Main Setup Menu 2nd Level Menu used to turn data exporting on or off, set the meter to be interfaced using the 34PS64#QPSU TFUUIFFYQPSUFEEBUBGPSNBUGPSBQSJOUFS TUSJOHPGUFYU PS1$ DPNNBEFMJNJUFEUFYU BOETFUUIFCBVESBUF t0GG t0O Menu used to turn on or off the data log feature. t%BUF t%%..:: t..%%:: t5JNF t)PVS$MPDL t)PVS$MPDL Menu used to set the date format as day/month/year or month/day/year; enter UIFEBUFWBMVFTTFUUIFUJNFGPSNBUBTIPVSPSIPVSDMPDLBOEFOUFSUIFUJNF WBMVFT6TFUIFOVNFSJDFOUSZTDSFFOUPFOUFSUIFWBMVFT t&OHMJTI t4QBOJTI t(FSNBO t'SFODI t*UBMJBO t$IJOFTF Menu used to set the language for all displayed meter prompts. ,FZ1SFTT#FFQ t0GG t0O Menu used to turn on or off the beep sound made every time a meter key is pressed. Alarm Beep t0GG t0O Menu used to turn on or off the beep sound made when an alarm value is reached. %BUB-PH Date / Time -BOHVBHF 12 Menu Description t1SJOUJOH t0O t0GG t$PNN4FUVQ t34 t64# t%BUB'PSNBU t1SJOUFS t1$ $47 t$PNN$POGJH t t t t t t &YQPSU%BUB Settings Menu Options Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Settings Menu (cont.) Main Setup Menu 2nd Level Stirrer Contrast Settings (cont.) Auto Shut Off 6TFS*% Menu Options t4QFFE t4QFFE t4QFFE t4QFFE t4QFFE Menu Description Menu used to turn the stirrer probe on or off and to set the stirrer probe speed. Star A213 meters only. t-FWFM t-FWFM t-FWFM t-FWFM t-FWFM t-FWFM Menu used to set the display contrast. t0GG t0O Menu used to turn on or off the meter automatic shutoff feature, which turns the NFUFSPGGXIFOOPLFZTBSFQSFTTFEGPSNJOVUFT Default value or last entered value .FOVVTFEUPTFUUIFVTFS*%6TFUIFBMQIBOVNFSJDFOUSZTDSFFOUPFOUFSUIFVTFS*% 4BNQMF*% t0GG t.BOVBM t"VUP*ODSFNFOUBM Star A213 and Star A323 meters only. .FOVVTFEUPUVSOUIFTBNQMF*%PGGPSPO8IFOTBNQMF*%JTTFUUPNBOVBMPSBVUP JODSFNFOUBM FOUFSUIFTBNQMF*%JOUIFNFBTVSFNFOUNPEFCZQSFTTJOHf2 (sample ID) and using the alphanumeric entry screen. Star A213 and Star A323 meters only. View Log Menu 5IF7JFX-PHTFUVQNFOVJTVTFEUPBDDFTTJOGPSNBUJPOTUPSFEJOUIFEBUBMPHBOEDBMJCSBUJPOMPH3FGFSUPUIF%BUB Storage and Retrieval chapter for detailed information on using this setup menu. Diagnostics Menu 5IF%JBHOPTUJDTTFUVQNFOVJTVTFEUPQFSGPSNUIFNFUFSTFMGUFTU SFTFUUIFNFUFSUPUIFGBDUPSZEFGBVMUTFUUJOHTBOE display meter information including serial number and software revision. Refer to the Customer Services chapter for detailed information on using this setup menu. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 13 This page intentionally left blank. 14 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 4 RDO/DO Calibration 1PMBSPHSBQIJD%0QSPCFTPOMZ"QPMBSPHSBQIJD%0QSPCFNVTUCFQPMBSJ[FE5IFQSPCFJTDPOUJOVPVTMZQPMBSJ[FEXIFO JUJTDPOOFDUFEUPUIFNFUFS*GUIFQSPCFJTOPUDPOOFDUFEUPUIFNFUFSDPOOFDUUIFQSPCFUPUIFNFUFS DPOOFDUUIF NFUFSUPBQPXFSTPVSDFBOEXBJUUPNJOVUFTGPSQPMBSJ[BUJPO 5IF0SJPO4UBS"BOE4UBS"NFUFSTDBOQFSGPSNBDBMJCSBUJPOVTJOHXBUFSTBUVSBUFEBJS "JS BJSTBUVSBUFE XBUFS 8BUFS 8JOLMFSUJUSBUJPO .BOVBM PS[FSPQPJOUDBMJCSBUJPO 4FU;FSP 4UFQCZTUFQJOTUSVDUJPOTBOEQSPNQUT BSFEJTQMBZFEPOUIFNFUFSUPBTTJTUPQFSBUPSTXJUIUIFDBMJCSBUJPONFOVT5IFNFUFSDBOTBWFVQUPDBMJCSBUJPOTJO the log and calibration data can be exported from the meter to a printer or computer. Air Dissolved Oxygen Calibration "OBJSDBMJCSBUJPOJTQFSGPSNFEJOXBUFSTBUVSBUFEBJSVTJOHUIFDBMJCSBUJPOTMFFWFJODMVEFEXJUIUIF%0QSPCF 5IJTJTUIFTJNQMFTUBOENPTUBDDVSBUFDBMJCSBUJPO%VFUPUIFJOIFSFOUEJGGFSFODFTCFUXFFOXBUFSTBUVSBUFEBJS BOEBJSTBUVSBUFEXBUFS TBUVSBUJPOXJMMCFEJTQMBZFEXIFOUIFDBMJCSBUJPOSFBEJOHJTTUBCMFXIFOVTJOHB polarographic DO probe. The highest possible accuracy is reached when calibration temperature is the same as the measuring temperature. Moisten the sponge or absorbent cloth in the calibration sleeve with distilled water and insert the probe into the sleeve without touching the water saturated material. For BOD measurements, this calibration can be performed in a BOD bottle. Note: In most calibration screens, press f1 (esc) to return to the measurement mode without saving the calibration. *OUIFNFBTVSFNFOUNPEF QSFTTf1 (cal). 2. Press or to highlight Air and press f3 (select). 3JOTFUIF3%0PQUJDBM%0QSPCFPSQPMBSPHSBQIJD%0QSPCFXJUIEJTUJMMFEXBUFS CMPUESZXJUIBMJOUGSFFUJTTVFBOEQMBDF JOUPUIFQSFQBSFEDBMJCSBUJPOTMFFWFPS#0%CPUUMF"MMPXUIFQSPCFBOEXBUFSTBUVSBUFEBJSUPSFBDIFRVJMJCSJVN 8IFOUIFQSPCFBOEXBUFSTBUVSBUFEBJSBSFSFBEZ QSFTTf3 (start). 8BJUGPSUIFEJTTPMWFEPYZHFOSFBEJOHPOUIFNFUFSUPTUBCJMJ[FBOETUPQnBTIJOH0ODFUIFSFBEJOHJTTUBCMF UIF meter will display Reading is stable. Accept Auto Calibration Value and 100.0% if using an RDO optical DO probe or 102.3 % if using a polarographic DO probe. 1SFTTf3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the calibration log and a printer or computer. The meter will proceed to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 15 Water Dissolved Oxygen Calibration "XBUFSDBMJCSBUJPOJTQFSGPSNFEVTJOHXBUFSUIBUJTTBUVSBUFEXJUIBJS#VCCMFBJSJOUPBXBUFSTBNQMFBOE gently stir the sample to prevent the buildup of air bubbles on the dissolved oxygen probe membrane. Note: In most calibration screens, press f1 (esc) to return to the measurement mode without saving the calibration. *OUIFNFBTVSFNFOUNPEF QSFTTf1 (cal). 2. Press or to highlight Water and press f3 (select). 3JOTFUIF%0QSPCFBOEBOZPUIFSFMFDUSPEFTJOVTFXJUIEJTUJMMFEXBUFS CMPUESZXJUIBMJOUGSFFUJTTVFBOEQMBDF JOUPUIFQSFQBSFEBJSTBUVSBUFEXBUFS"MMPXUIF%0QSPCFBOEBJSTBUVSBUFEXBUFSUPSFBDIFRVJMJCSJVN 8IFOUIF%0QSPCFBOEBJSTBUVSBUFEXBUFSBSFSFBEZ QSFTTf3 (start). 8BJUGPSUIFEJTTPMWFEPYZHFOSFBEJOHPOUIFNFUFSUPTUBCJMJ[FBOETUPQnBTIJOH0ODFUIFSFBEJOHJTTUBCMF UIF meter will display Reading is stable. Accept Auto Calibration Value and 100 %. 1SFTTf3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the calibration log and a printer or computer. The meter will automatically proceed to the measurement mode. 16 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Manual Dissolved Oxygen Calibration A manual calibration is performed using a water sample with a known concentration of dissolved oxygen. This method can be used to calibrate the DO probe to the value achieved by a Winkler titration. A manual calibration involves performing a Winkler titration and using that sample as a calibration standard. The oxygen level result from the titration is entered in a manual calibration as the dissolved oxygen value. This correlates the meter input to the Winkler titration. This method is inherently less accurate, due to the possibility of titration errors. Note: In most calibration screens, press f1 (esc) to return to the measurement mode without saving the calibration. *OUIFNFBTVSFNFOUNPEF QSFTTf1 (cal). 2. Press or to highlight Manual and press f3 (select). 3JOTFUIF%0QSPCFBOEBOZPUIFSFMFDUSPEFTJOVTFXJUIEJTUJMMFEXBUFS CMPUESZXJUIBMJOUGSFFUJTTVFBOE place into the prepared water sample with a known dissolved oxygen concentration. Allow the DO probe and water sample to reach equilibrium. 8IFOUIF%0QSPCFBOEXBUFSTBNQMFBSFSFBEZ QSFTTf3 (start). 8BJUGPSUIFEJTTPMWFEPYZHFOSFBEJOHPOUIFNFUFSUPTUBCJMJ[FBOETUPQnBTIJOH1FSGPSNPOFPGUIFGPMMPXJOHBDUJPOT a. Press f2 (accept)UPBDDFQUUIFEJTQMBZFEEJTTPMWFEPYZHFOWBMVFJONH- NJMMJHSBNTQFSMJUFS b. Press f3 (edit) to access the numeric entry screen and edit the dissolved oxygen value. i. Press , , or to highlight a number or decimal point, press f3 (enter) to select UIFIJHIMJHIUFEJUFNBOESFQFBUVOUJMUIFEJTTPMWFEPYZHFOWBMVFJONH-JTTIPXO ii. Press f2 (done) to exit the numeric entry screen. iii. Press f2 (accept) to accept the entered dissolved oxygen value. 1SFTTf3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the calibration log and a printer or computer. The meter will automatically proceed to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 17 Set Zero Dissolved Oxygen Calibration "[FSPQPJOUDBMJCSBUJPOJTQFSGPSNFEJOBOPYZHFOGSFFTPMVUJPO;FSPUIFQSPCFXIFOVTJOHBOFXNFNCSBOF VTJOHGSFTIFMFDUSPMZUFTPMVUJPOPSXIFONFBTVSJOHEJTTPMWFEPYZHFOMFWFMTCFMPXTBUVSBUJPOPSNH- "[FSPQPJOUDBMJCSBUJPOJTOPUHFOFSBMMZSFRVJSFEVOMFTTNFBTVSFNFOUTXJMMCFUBLFOCFMPXTBUVSBUJPOPS NH-1FSGPSNBOBJSPSXBUFSDBMJCSBUJPOCFGPSFQFSGPSNJOHB[FSPQPJOUDBMJCSBUJPO Note: In most calibration screens, press f1 (esc) to return to the measurement mode without saving the calibration. *OUIFNFBTVSFNFOUNPEF QSFTTf1 (cal). 2. Press or to highlight Set Zero and press f3 (select). 3. Rinse the RDO optical DO probe or polarographic DO probe and any other electrodes in use with distilled XBUFS CMPUESZXJUIBMJOUGSFFUJTTVFBOEQMBDFJOUPUIFQSFQBSFE[FSPPYZHFOTUBOEBSE"MMPXUIFQSPCF and standard to reach equilibrium. 8IFOUIFQSPCFBOE[FSPPYZHFOTUBOEBSEBSFSFBEZ QSFTT f3 (start). 8BJUGPSUIFEJTTPMWFEPYZHFOSFBEJOHPOUIFNFUFSUPTUBCJMJ[FBOETUPQnBTIJOH0ODFUIFSFBEJOHJT stable, the meter will display Reading is stable. Accept Auto Calibration Value and 0.00. 1SFTTf3 (cal done) to export the data to the calibration log or press f2 (print) to export the data to the calibration log and a printer or computer. The meter will proceed to the measurement mode. 18 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 5 Temperature Calibration 5IFNFUFS"5$UFNQFSBUVSFEJTQMBZIBTBSFMBUJWFBDDVSBDZPG¡$"5$QSPCFT CPUITFQBSBUFBOEUIPTFCVJMUJOUP FMFDUSPEFT IBWFWBSZJOHUFNQFSBUVSFBDDVSBDJFT VTVBMMZ¡$UP¡$6TFUIJTGVODUJPOPOMZJGJUJTOFDFTTBSZ to calibrate the temperature readings taken by the ATC probe. Since the temperature offset calculated during the calibration is applied to all future temperature measurements, recalibrate if a different ATC probe is used. Temperature calibration is for the calibration of the solution temperature measured by a DO probe, the membrane UFNQFSBUVSFNFBTVSFECZB%0QSPCFPSBDPNCJOBUJPOPGUIFTF*GNBOVBMUFNQFSBUVSFDPNQFOTBUJPOJTCFJOHVTFE BOEUIFEJTQMBZTIPXT."/BTUIFUFNQFSBUVSFTPVSDFJDPO TFUUIFNBOVBMUFNQFSBUVSFWBMVFVTJOHUIF.BOVBM 5FNQ7BMVFNFOV5IFUFNQFSBUVSFDBMJCSBUJPONFOVJTOPUBDDFTTJCMFVOMFTTBO"5$QSPCFJTDPOOFDUFEUPUIFNFUFS *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press , , or . to highlight DO/RDO Channel and press f3 (select). 3. Press or to highlight Temperature and press f3 (select). 1SFTT or to highlight Temperature Calibration and press f3 (select). 1SFTT or to highlight Solution Temperature, Membrane Temperature or Sol & Mem Temperature to identify the temperature source that will be calibrated and press f3 (select). 1MBDFUIF%0QSPCFBOEUIFSNPNFUFSTJOUPBTPMVUJPOXJUIBLOPXO TUBCMFUFNQFSBUVSF*UJTSFDPNNFOEFEUIBUUXP/*45 traceable thermometers be used to measure and verify the temperature of the solution. 8BJUGPSUIFUFNQFSBUVSFSFBEJOHTPGUIF%0QSPCFBOEUIFSNPNFUFSTUPTUBCJMJ[F VTVBMMZUXPUPmWFNJOVUFT 8. Press f3 (edit) to access the numeric entry screen and edit the temperature value. a. Press , , or to highlight a number, decimal point or negative sign; press f3 (enter) to select the highlighted item and repeat until the temperature value read by the thermometers is shown on the display. b. Press f2 (done) to exit the numeric entry screen. 5IFNFUFSXJMMEJTQMBZUIFFOUFSFEUFNQFSBUVSFWBMVFPOUIFReference Temp line, the original temperature read by the DO probe on the ATC line and the temperature offset value that will be applied to all future temperature readings on the Offset line. Press f2 (accept) to proceed with the displayed temperature data, save and end the calibration and export the data to the calibration log. 1SFTT f1 (meas) to proceed to the measurement mode or press f2 (print) to proceed to the measurement mode and export the data to a printer or computer. The meter will automatically proceed to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 19 This page intentionally left blank. 20 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 6 Measurement 5IF0SJPO4UBS4UBS" 4UBS"BOE4UBS"NFUFSTBSFDBQBCMFPGTIPXJOH%0TBU EJTTPMWFEPYZHFOJO QFSDFOUTBUVSBUJPO %0NH- EJTTPMWFEPYZHFOJONJMMJHSBNTQFSMJUFS PS%0¡$ QSPCFNFNCSBOFUFNQFSBUVSF measurements on the display. Press while taking a measurement in the continuous measurement mode to freeze the display and press a second time to unfreeze the display and continue the measurement. Press while taking a measurement to manually export the measurement to the data log, if the data log is enabled in the setup menu. 1. Rinse the RDO optical dissolved oxygen probe or polarographic dissolved oxygen probe and any other electrodes in VTFXJUIEJTUJMMFEXBUFS CMPUESZXJUIBMJOUGSFFUJTTVFBOEQMBDFJOUPUIFTBNQMF 2. Star A213 meters onlyo*GUIFTUJSSFSQSPCFJTJOVTFBOEUIFNFUFSJTJODPOUJOVPVTPSUJNFENPEF QSFTT UPUVSOPOUIFTUJSSFSQSPCF*GUIFTUJSSFSQSPCFJTJOVTFBOEUIFNFUFSJTJO"6503&"%NPEF UIFTUJSSFSQSPCF will start stirring when is pressed and stop stirring when the reading stabilizes. 3. Start the measurement and wait for it to stabilize. B *GUIFNFUFSJTJO"6503&"%NPEF EFGBVMUTFUUJOH QSFTT the to start the measurement. When JDPOTUPQTnBTIJOH SFDPSEUIFBQQMJDBCMFNFBTVSFNFOUQBSBNFUFSTBOEUFNQFSBUVSFPGUIF sample. Press again to start a new measurement. C *GUIFNFUFSJTJODPOUJOVPVTNPEF UIFNFUFSXJMMJNNFEJBUFMZTUBSUUBLJOHBNFBTVSFNFOUBOE update the display whenever the measurement changes. Wait for the display to show ready and record the applicable measurement parameters and temperature of the sample. c. Star A213 and Star A323 meters only –*GUIFNFUFSJTJOUJNFENPEF UIFNFUFSXJMMMPHNFBTVSFNFOUT at the preselected time interval, regardless of the measurement stability. The meter will update the display whenever the measurement changes, so the applicable measurement parameters and temperature of the sample can be recorded when the display shows ready. Star A213 meters onlyo*GUIFTUJSSFSQSPCFJTJOVTFBOEUIFNFUFSJTJODPOUJOVPVTPSUJNFENPEF QSFTT to turn off the stirrer probe. 3FNPWFUIFFMFDUSPEFTGSPNUIFTBNQMF SJOTFXJUIEJTUJMMFEXBUFS CMPUESZBOEQMBDFJOUPUIFOFYUTBNQMF 3FQFBUTUFQTUISPVHIGPSBMMTBNQMFT 8IFOBMMTBNQMFTIBWFCFFONFBTVSFE TUPSFUIFFMFDUSPEFTBDDPSEJOHUPUIFJSVTFSHVJEFT Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 21 This page intentionally left blank. 22 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 7 Methods The Orion Star A213 and Star A323 meters can save up to ten methods per channel and the corresponding calibration data for each method, for the fast and easy recollection of different meter setup parameters. The default meter TFUUJOHJTUIBUOPNFUIPEJTVTFEBOEUIFNFUIPEOVNCFSXJMMCFTIPXOBT.JGOPNFUIPEJTJOVTF5IFDVSSFOU NFUFSTFUUJOHTDBOCFTBWFEJOUIFTFUVQNFOV&YJTUJOHNFUIPETDBOCFTFMFDUFEGSPNUIFNFUIPETMJTUBOESVOPO the meter. Methods can be viewed, edited, copied to a new method or deleted. Saving the Current Meter Settings as a New Method . *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press , 3. Press , or or to highlight DO/RDO Channel and press f3 (select). to highlight Method and press f3 (select 5IFNFUFSXJMMEJTQMBZCurrent Settings and a list of methods. The list will show the sequential number of the methods (M301) and the date, time and mode of each method (07/01/11 12:45 DO) if methods have been previously created. 1SFTT or to highlight Current Settings and press f3 (save). 1SFTT or to highlight a method number that the current settings will be saved as and press f2 (accept). 5IFNFUFSXJMMQSPNQUGPSBNFUIPETQFDJmDQBTTXPSEUPCFDSFBUFE5IFQBTTXPSENVTUCFBUMFBTUDIBSBDUFSTMPOH a. Press f3 (edit) to access the numeric entry screen. b. Press , , or to highlight a number, press f3 (enter) to select the highlighted number and repeat until the new password is shown. c. Press f2 (done) to exit the numeric entry screen. d. Press f2 (accept) to accept the entered password. 8. The meter will automatically proceed to the measurement mode. Loading an Existing Method *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press 3. Press , , or or . to highlight DO/RDO Channel and press f3 (select). to highlight Method and press f3 (select). 5IFNFUFSXJMMEJTQMBZCurrent Settings and a list of methods. The list will show the sequential number of the methods (M301) and the date, time and mode of each method (07/01/11 12:45 DO) if methods have been previously created. 1SFTT or to highlight the method to be loaded and press f2 (load). 5IFNFUFSXJMMBVUPNBUJDBMMZQSPDFFEUPUIFNFBTVSFNFOUNPEF Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 23 Editing, Copying or Deleting an Existing Method . *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press 3. Press , , or or to highlight DO/RDO Channel and press f3 (select). to highlight Method and press f3 (select). 5IFNFUFSXJMMEJTQMBZCurrent Settings and a list of methods. The list will show the sequential number of the methods (M301) and the date, time and mode of each method (07/01/11 12:45 DO) if methods have been previously created. 1SFTT or to highlight the desired method and press f3 (options). &OUFSUIFNFUIPETQFDJmDQBTTXPSE a. Press f3 (edit) to access the numeric entry screen. b. Press , , or to highlight a number, press f3 (enter) to select the highlighted number and repeat until the password is shown. c. Press f2 (done) to exit the numeric entry screen. d. Press f2 (accept) to accept the entered password. 1SFTT or to highlight Edit, Copy or Delete and press f2 (accept). B *GEdit is selected – press or to highlight any setup menu parameters that need to be changed and press f3 (select). Review and change all applicable setup menu parameters. Press f1 (back) to return to the list of methods and then press C *GCopy is selected – press or to return to the measurement mode. to highlight a method number that the selected method will be copied to and press f2 (accept). The meter will automatically proceed to the measurement mode. D *GDelete is selected – press f2 (yes) to delete the method or press f3 (no) to keep the method. The meter will automatically proceed to the measurement mode. 24 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 8 Data Storage and Retrieval Data Storage Settings The data and calibration storage settings include the measurement read type, computer and printer export settings and data log settings. The measurement read type determines when the meter sends measurements to the data log, if the data log is enabled in the setup menu, and to a printer or computer, if a printer or computer is connected to the meter and enabled in the setup menu. Review the date and time settings and update as needed. Read Type Selection *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press , 3. Press or to highlight Mode and Settings and press f3 (select). 1SFTT or to highlight Read Type and press f3 (select). 1SFTT or to highlight Auto, Continuous or Timed and press f3 (select). a. , or . to highlight DO/RDO Channel and press f3 (select). Star A213 and Star A323 meters only –*GTimed is selected and the time interval needs to be changed – highlight Timed; press UPIJHIMJHIUIPVST )) NJOVUFT .. PSTFDPOET 44 QSFTTf3 (edit) to access the numeric entry screen; use the numeric entry screen to change the values and press f1 (back) when the time interval is correct. 1SFTT to return to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 25 Computer and Printer Export Settings *OUIFNFBTVSFNFOUNPEF QSFTT , or . 2. Press , to highlight Settings and press f3 (select). 3. Press or to highlight Export Data and press f3 (select). 1SFTT or to highlight Printing and press f3 (select). Press or to highlight On or Off and press f3 (select). Select On to allow data to be sent to a computer or printer. or 1SFTT to highlight Comm Setup and press f3 (select). Press or to highlight RS232 or USB and press f3 (select). Select RS232 if the meter will be interfaced using the RS232 port and select USB JGUIFNFUFSXJMMCFJOUFSGBDFEVTJOHUIF64#QPSU or 1SFTT to highlight Data Format and press f3 (select). Press or to highlight Printer or PC (CSV) and press f3 (select). Select Printer to export the data as a string of text and select PC (CSV) to export the data in comma delimited format. 1SFTT or to highlight Comm Config and press f3 (select). Press or to highlight 1200, 2400, 4800, 9600, 19200 or 38400 and press f3 (select). Select the baud rate best for the data transfer requirements. The fixed meter output settings are 8 bits, 1 stop bit and parity none. 8. Press f1 (back) and then press to return to the measurement mode. Data Log Settings *OUIFNFBTVSFNFOUNPEF QSFTT , or 2. Press , 3. Press or to highlight Data Log and press f3 (select). 1SFTT or to highlight Off or On and press f3 (select). 1SFTTf1 (back) and then press 26 . to highlight Settings and press f3 (select). to return to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Viewing the Calibration Log and Data Log 5IF0SJPO4UBS"BOE4UBS"TFSJFTNFUFSTTBWFVQUPUFOPGUIFNPTUSFDFOUDBMJCSBUJPOTQFSDIBOOFM5IF4UBS "NFUFSTBWFTVQUPTFUTPGEBUBQPJOUT UIF4UBS"NFUFSTBWFTVQUPTFUTPGEBUBQPJOUTBOEUIF 4UBS"NFUFSTBWFTVQUPTFUTPGEBUBQPJOUT"MPHOVNCFSJTBTTJHOFEUPFBDIEBUBQPJOU5IFSFBEUZQFPG the displayed channel or channels determines when measurements are exported to the data log. When a data point is exported to a computer or printer, the time stamp will include the hour, minutes and seconds. Viewing the Calibration Log *OUIFNFBTVSFNFOUNPEF QSFTT . 2. Press , 3. Press or to highlight Calibration Log and press f2 (accept). 1SFTT or to highlight DO/RDO – Channel and press f2 (select). 1SFTT or to highlight DO or RDO and press f2 (select). , or to highlight View Log and press f3 (select). 5IFNFUFSXJMMEJTQMBZBMJTUPGDBMJCSBUJPOTGPSUIFTFMFDUFEDIBOOFMBOEDBMJCSBUJPOUZQF5IFMJTUTIPXTUIF sequential number of the calibration and the date and time it was saved (07/01/2011 12:45). or 5PWJFXUIFDBMJCSBUJPOEBUB QSFTT to highlight a specific calibration and press f2 (select). Press f2 (print) to print the calibration or press f1 (back) to return to the list of calibrations. to return to the measurement mode. 8. Press Viewing the Data Log *OUIFNFBTVSFNFOUNPEF QSFTT , or . 2. Press , to highlight View Log and press f3 (select). 3. Press or to highlight Data Log and press f2 (accept). 1SFTT or to highlight DO/RDO – Channel and press f2 (select). 5IFNFUFSXJMMEJTQMBZBMJTUPGUIFEBUBQPJOUT5IFMJTUTIPXTUIFTFRVFOUJBMOVNCFSPGUIFEBUBQPJOUBOEUIF date and time the data point was saved (07/01/2011 12:45). 5PWJFXUIFNFBTVSFNFOUJOGPSNBUJPOGPSBOJOEJWJEVBMEBUBQPJOU QSFTT or to highlight the data point and press f2 (select). Press f2 (print) to print the data point or press f1 (back) to return to the list of data points. 1SFTT to return to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 27 Exporting the Data Log to a Computer or Printer *OUIFNFBTVSFNFOUNPEF QSFTT . 2. Press , 3. Press or to highlight Data Log and press f2 (accept). 1SFTT or to highlight DO/RDO – Channel and press f3 (select). , or to highlight View Log and press f3 (select). 5IFNFUFSXJMMEJTQMBZBMJTUPGUIFEBUBQPJOUT5IFMJTUTIPXTUIFTFRVFOUJBMOVNCFSPGUIFEBUBQPJOUBOEUIF date and time the data point was saved (07/01/2011 12:45). 1SFTTf3 (options). 1SFTT or to highlight Log Export and press f2 (accept). 8. Press or to highlight Today, Last 10, Range or All as the data log points to be exported and press f2 (accept). B *GToday, Last 10 or All is selected – press f2 (yes) to export the data. C *GRange is selected – enter the first and last date points: i. Press f3 (edit) to display the numeric entry screen. ii. Press , , or to highlight a number, press f3 (enter) to select the highlighted number and repeat until the number of the first data point to be exported is shown on the display. iii. Press f2 (done) to exit the numeric entry screen. iv. Press to enter the last data point. v. Press f3 (edit) to display the numeric entry screen. vi. Press , , or to highlight a number, press f3 (enter) to select the highlighted number and repeat until the number of the last data point to be exported is shown on the display. vii. Press f2 (done) to exit the numeric entry screen. viii. Press f2 (accept) and then press f2 (yes) to export the data. "GUFSFYQPSUJOHUIFEBUB UIFNFUFSXJMMBVUPNBUJDBMMZSFUVSOUPUIFNFBTVSFNFOUNPEF 28 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Clearing the Data Log *OUIFNFBTVSFNFOUNPEF QSFTT . 2. Press , 3. Press or to highlight Data Log and press f2 (accept). 1SFTT or to highlight RDO/DO – Channel and press f3 (select). , or to highlight View Log and press f3 (select). 5IFNFUFSXJMMEJTQMBZBMJTUPGUIFEBUBQPJOUT5IFMJTUTIPXTUIFTFRVFOUJBMOVNCFSPGUIFEBUBQPJOUBOEUIF date and time the data point was saved (07/01/2011 12:45). 1SFTTf3 (options). 1SFTT or to highlight Log Clear and press f2 (accept). 8. Press f2 (yes) twice to clear the entire data log. &OUFSUIFQBTTXPSE5IFEFGBVMUJT111111 and pressing f2 (accept) will advance the meter to the next step. 1SFTTf1 (back) and then press to return to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 29 Interfacing a Printer 5IF0SJPO4UBSQSJOUFS $BU/P JTSFDPNNFOEFEGPSVTFXJUIUIF0SJPO4UBS"BOE4UBS"TFSJFT NFUFST5IF0SJPO4UBSQSJOUFSIBTBCBVESBUFBOEJUJTQBDLBHFEXJUIUIF34QSJOUFSDBCMF $BU/P XIJDIJTSFRVJSFEUPJOUFSGBDFBO0SJPO4UBS"NFUFSUPBQSJOUFS5IFCBVESBUFPGUIF0SJPO4UBS" BOE4UBS"TFSJFTNFUFSTDBOCFTFUUP PSGPSDPNNVOJDBUJPOUPEJGGFSFOU QSJOUFST5IFmYFENFUFSTFUUJOHTBSFOVNCFSPGCJUT TUPQCJUT QBSJUZOPOF5IFnPXDPOUSPMGPSUIFQSJOUFS TIPVMECFTFUUP90/90''5IFNFUFSXJMMTFOENFBTVSFNFOUTBOEDBMJCSBUJPOEBUBUPUIFQSJOUFSJGUIFQSJOUFS option is turned on in the setup menu. Alternatively, measurements and calibration data can be sent to the data log and calibration log. From the data log and calibration log, the operator can chose to print a single data log point, a range of data log points or the entire data log. Interfacing a Computer 5IF0SJPO4UBS"BOE4UBS"TFSJFTNFUFSTDBOTFOENFBTVSFNFOUTBOEDBMJCSBUJPOEBUBUPBDPNQVUFSJOB DPNNBEFMJNJUFEGPSNBUUIBUJTFBTZUPQBSTFJODPNQVUFSQSPHSBNTMJLF&YDFM$POOFDUUIF34DPNQVUFSDBCMF $BU/P UPUIF34JOQVUPOUIFNFUFSBOEUIF34JOQVUPOBDPNQVUFS5IFCBVESBUFPGUIF0SJPO 4UBS"TFSJFTNFUFSTDBOCFTFUUP PS5IFmYFENFUFSTFUUJOHTBSFOVNCFS PGCJUT TUPQCJUT QBSJUZOPOF5IFnPXDPOUSPMGPSUIFDPNQVUFSTIPVMECFTFUUP90/90''5IFNFUFSXJMM send measurements and calibration data to the computer if the computer option is turned on in the setup menu. Alternatively, measurements and calibration data can be sent to the data log and calibration log. From the data log and calibration log, the operator can chose to send a single data log point, a range of data log points or the entire data log to the computer. A complimentary copy of general data logging software is available for use with the Orion Star A200 and Star A300 series meters. This can be found on the CD included with the meter or at www.thermoscientific.com/water. 30 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 9 Customer Services Meter Errors and Recommended Actions Error Recommended Actions %JTQMBZ&SSPS *GUIJTFSSPSPDDVST DPOUBDU5FDIOJDBM4VQQPSU )BSEXBSF&SSPS *GUIJTFSSPSPDDVST DPOUBDU5FDIOJDBM4VQQPSU $IBOOFM*OQVU&SSPS Disconnect all of the electrodes from the meter and repeat the self test. 3FGFSFODF*OQVU&SSPS Make sure that all of the electrodes are disconnected from the meter and repeat the self test. (SPVOE*OQVU&SSPS Make sure that all of the electrodes are disconnected from the meter and repeat the self test. ,FZQBE'BJMVSF Repeat the self test. When the meter prompts, press each of the keys one at a time, including the QPXFSLFZ XJUIJOGJWFTFDPOETPGPOFPUIFS*GUIFFSSPSQFSTJTUT DPOUBDU5FDIOJDBM4VQQPSU Over Range Measurement or 6OEFS3BOHF.FBTVSFNFOU *GUIFNFBTVSFNFOUJTnBTIJOHBOEPWFSSBOHFPSVOEFSSBOHF UIFNFBTVSFNFOUWBMVFJT outside of the allowable measurement range. Make sure that the electrode is connected to the appropriate meter input and the electrode parameters are entered correctly in the setup menu. $MFBOUIFFMFDUSPEFBDDPSEJOHUPUIFFMFDUSPEFVTFSHVJEFBOESFDBMJCSBUFUIFFMFDUSPEFXJUIOFX CVGGFSTPSTUBOEBSET*GUIFFSSPSQFSTJTUT QFSGPSNUIFNFUFSTFMGUFTU Measurement Out of Range Make sure that the electrode is connected to the appropriate meter input and the electrode parameters are entered correctly in the setup menu. Clean the electrode according to the electrode VTFSHVJEFBOESFDBMJCSBUFUIFFMFDUSPEFXJUIOFXCVGGFSTPSTUBOEBSET1FSGPSNUIFNFUFSTFMGUFTU Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 31 Meter Self Test and Checkout Meter Self Test *OUIFNFBTVSFNFOUNPEF QSFTTTFUVQ 2. Press , , 3. Press or or . to highlight Diagnostics and press f3 (select). to highlight Self Test and press f2 (accept). %JTDPOOFDUBMMPGUIFFMFDUSPEFTBOEQSPCFTGSPNUIFNFUFSBOEQSFTTf2 (yes). 1SFTTf2 (yes) to start the self test. 5IFNFUFSXJMMQFSGPSNBOBDDVSBDZUFTU8IFOUIFNFUFSEJTQMBZTAccuracy Test Passed, press f2 (next). 5IFNFUFSXJMMQFSGPSNBO&130.UFTU8IFOUIFNFUFSEJTQMBZTE2Prom Test Passed, press f2 (next). 5IFNFUFSXJMMQFSGPSNBLFZQBEUFTU1SFTTFBDIPGUIFLFZTPOUIFLFZQBE JODMVEJOH POFBUBUJNFJO any order. When the meter displays Keypad Test Passed, press f2 (next). 5IFNFUFSXJMMEJTQMBZSelf Test Passed. Press 32 to return to the measurement mode. Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Electrode Stability Test *OUIFNFBTVSFNFOUNPEF QSFTT . 2. Press , 3. Press or to highlight Stability Test and press f2 (accept). 1SFTT or to highlight DO/RDO – Channel and press f2 (next). , or to highlight Diagnostics and press f3 (select). .BLFTVSFUIFFMFDUSPEFPSQSPCFUPCFUFTUFEJTDPOOFDUFEUPUIFDIBOOFMTFMFDUFEJOUIFQSFWJPVTTUFQBOE press f2 (yes). 1MBDFUIFFMFDUSPEFPSQSPCFJOBOBQQSPQSJBUFTPMVUJPOXJUIBTUBCMFUFNQFSBUVSFBOEQSFTTf2 (yes). B"QSFQBSFEXBUFSTBUVSBUFEBJSDBMJCSBUJPOTMFFWFJTSFDPNNFOEFEGPSUFTUJOH3%0PQUJDBM dissolved oxygen and polarographic dissolved oxygen probes. 5IFNFUFSXJMMQFSGPSNUIFTUBCJMJUZUFTUBOETIPXUIFQFSNJOVUFESJGUBOEOPJTFPOUIFEJTQMBZ 8. The meter will display Stability Test Passed or Stability Test Failed. Press f1 (esc) or measurement mode. to return to the Meter Factory Reset After a factory reset is performed, all of the meter settings will be reset to the factory defaults and the data log, calibration log and methods will be deleted. *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press , , 3. Press or or . to highlight Diagnostics and press f3 (select). to highlight Factory Reset and press f2 (accept). 1SFTTf2 (yes) to reset the meter. 5IFNFUFSXJMMQBVTF QPXFSPGGBOESFTUBSUXJUIUIFGBDUPSZEFGBVMUTFUUJOHT Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 33 Meter User Reset After a user reset is performed, all of the meter setup menu settings will be reset to the defaults; however, the data log, calibration log and methods will be retained. *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press , , 3. Press or or . to highlight Diagnostics and press f3 (select). to highlight User Reset and press f2 (accept). 1SFTTf2 (yes) to reset the meter. 5IFNFUFSXJMMQBVTFBOEUIFOSFUVSOUPUIFNFBTVSFNFOUNPEFXJUIUIFEFGBVMUTFUVQNFOVTFUUJOHT About Meter *OUIFNFBTVSFNFOUNPEF QSFTT 2. Press , 3. Press or , or . to highlight Diagnostics and press f3 (select). to highlight About Meter and press f2 (accept). 5IFNFUFSNPEFM NFBTVSFNFOUQBSBNFUFST TFSJBMOVNCFSBOETPGUXBSFSFWJTJPOXJMMCFEJTQMBZFE 1SFTTf1 (back) to return to the diagnostics menu or press to return to the measurement mode. Assistance "GUFSUSPVCMFTIPPUJOHBMMDPNQPOFOUTPGZPVSNFBTVSFNFOUTZTUFN DPOUBDU5FDIOJDBM4VQQPSU8JUIJOUIF6OJUFE4UBUFTDBMM BOEPVUTJEFUIF6OJUFE4UBUFTDBMMPSGBY*O&VSPQF UIF.JEEMF&BTUBOE"GSJDB contact your local authorized dealer. For the most current contact information, visit www.thermoscientific.com/water. Warranty and Registration To register your meter and for the most current warranty information, visit www.thermoscientific.com/water. 34 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Ordering Information Orion Star A200 Series Benchtop Meters Cat. No. Description STARA2110 4UBS"Q)#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE STARA2115 4UBS"Q)#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/6.%3044Q)"5$5SJPEF 3044Q)#VGGFS,JU STARA2120 4UBS"$POEVDUJWJUZ#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE STARA2125 4UBS"$POEVDUJWJUZ#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE.%$POEVDUJWJUZ$FMM $POEVDUJWJUZç4DN4UBOEBSE STARA2126 4UBS"$POEVDUJWJUZ#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE.%$POEVDUJWJUZ$FMMXJUI %FUBDIBCMF'MPX5ISPVHI$FMM$POEVDUJWJUZç4DN4UBOEBSE STARA2130 4UBS"3%0%0#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE STARA2135 4UBS"3%0%0#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE.%1PMBSPHSBQIJD%01SPCFXJUI $BMJCSBUJPO4MFFWF1SPCF.BJOUFOBODF,JU#0%'VOOFM 4UJSSFSBOE"EBQUFS STARA2136 4UBS"3%0%0#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE.%"65045*3%0#0%1SPCF 1PMBSPHSBQIJD&MFDUSPMZUF4PMVUJPO1SPCF.BJOUFOBODF,JU STARA2140 4UBS"Q)*4&#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE STARA2145 4UBS"Q)*4&#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/68130446MUSBQ)&MFDUSPEF .%"5$1SPCF4UJSSFS1SPCF3044Q)#VGGFS,JU STARA2146 4UBS"Q)*4&#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/68130446MUSBQ)&MFDUSPEF .%"5$1SPCF)1#/81)JHI1FSGPSNBODF"NNPOJB&MFDUSPEF4UJSSFS1SPCF "NNPOJBQQN4UBOEBSE-PXMFWFM"NNPOJB*4""NNPOJB&MFDUSPEF Storage Solution STARA2147 4UBS"Q)*4&#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/68130446MUSBQ)&MFDUSPEF .%"5$1SPCF#/81'MVPSJEF&MFDUSPEF4UJSSFS1SPCF'MVPSJEFQQN XJUI5*4"#**4UBOEBSE'MVPSJEFQQNXJUI5*4"#**4UBOEBSE'MVPSJEFQQNXJUI 5*4"#**4UBOEBSE5*4"#** STARA2148 4UBS"Q)*4&#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/68130446MUSBQ)&MFDUSPEF .%"5$1SPCF#/8130444PEJVN&MFDUSPEFXJUI4PEJVN4UBOEBSET 3FBHFOUTBOE 4PMVUJPOT4UJSSFS1SPCF STARA2150 4UBS"Q)$POEVDUJWJUZ#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE STARA2155 4UBS"Q)$POEVDUJWJUZ#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/6.%3044Q)"5$ 5SJPEF.%$POEVDUJWJUZ$FMM3044Q)#VGGFS,JU$POEVDUJWJUZç4DN Standard STARA2160 4UBS"Q)3%0%0#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE STARA2165 4UBS"Q)3%0%0#FODIUPQ.FUFSXJUI&MFDUSPEF4UBOE#/6.%3044Q)"5$5SJPEF .%1PMBSPHSBQIJD%01SPCFXJUI$BMJCSBUJPO4MFFWF3044Q)#VGGFS,JU 1SPCF.BJOUFOBODF,JU#0%'VOOFM 4UJSSFSBOE"EBQUFS Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 35 Ordering Information (cont.) Orion Star A200 Series Portable Meters Cat. No. Description STARA2210 4UBS"Q)1PSUBCMF.FUFS STARA2215 4UBS"Q)1PSUBCMF.FUFS68..%3044Q)"5$5SJPEFXJUI.FUFS$BCMFQ)#VGGFS 1PVDIFTQ)#VGGFS1PVDIFTQ)#VGGFS1PVDIFT3044&MFDUSPEF4UPSBHF 4PMVUJPO3JOTF4PMVUJPO1PVDIFT45"3"$44UBS"$BSSZJOH$BTF45"3""34UBS".FUFS"SNPS STARA2220 Star A222 Conductivity Portable Meter STARA2225 4UBS"$POEVDUJWJUZ1PSUBCMF.FUFS.%$POEVDUJWJUZ$FMMXJUI.FUFS$BCMF $POEVDUJWJUZç4DN4UBOEBSE1PVDIFT3JOTF4PMVUJPO1PVDIFT45"3"$44UBS"$BSSZJOH$BTF 45"3""34UBS".FUFS"SNPS STARA2230 Star A223 RDO/DO Portable Meter STARA2235 4UBS"3%0%01PSUBCMF.FUFS.%3%00QUJDBM%01SPCFXJUI.FUFS$BCMF45"3"$44UBS" $BSSZJOH$BTF45"3""34UBS".FUFS"SNPS STARA3210 4UBS"Q)1PSUBCMF.FUFS STARA3215 4UBS"Q)1PSUBCMF.FUFS68..%3044Q)"5$5SJPEFXJUI.FUFS$BCMFQ)#VGGFS 1PVDIFTQ)#VGGFS1PVDIFTQ)#VGGFS1PVDIFT3044&MFDUSPEF4UPSBHF 4PMVUJPO3JOTF4PMVUJPO1PVDIFT45"3"$44UBS"$BSSZJOH$BTF45"3""34UBS".FUFS"SNPS STARA3220 Star A322 Conductivity Portable Meter STARA3225 4UBS"$POEVDUJWJUZ1PSUBCMF.FUFS.%$POEVDUJWJUZ$FMMXJUI.FUFS$BCMF $POEVDUJWJUZç4DN4UBOEBSE1PVDIFT3JOTF4PMVUJPO1PVDIFT45"3"$44UBS"$BSSZJOH$BTF 45"3""34UBS".FUFS"SNPS STARA3230 Star A323 RDO/DO Portable Meter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ç4DN4UBOEBSE1PVDIFT3JOTF4PMVUJPO1PVDIFT45"3"$44UBS"$BSSZJOH$BTF45"3""3 Star A Meter Armor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ç4DN4UBOEBSE1PVDIFT 3JOTF4PMVUJPO1PVDIFT45"3"$44UBS"$BSSZJOH$BTF45"3""34UBS".FUFS"SNPS 36 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Ordering Information (cont.) Orion Star A Series Accessories and Electrodes Cat. No. Description STARA-BEA 0SJPO4UBS"4FSJFT&MFDUSPEF"SNBOE)PMEFS "UUBDIFTUPCBTFPGNFUFSPS45"3")#CBTF STARA-HB 0SJPO4UBS"4FSJFT&MFDUSPEF4UBOE#BTF0OMZ 6TFXIFOFMFDUSPEFBSNJTOPUBUUBDIFEUPNFUFS STARA-CS 0SJPO4UBS"4FSJFT1PSUBCMF)BSE$BSSZJOH$BTF STARA-AR 0SJPO4UBS"4FSJFT1PSUBCMF.FUFS"SNPSXJUI4UBOE JODMVEFTPOFQ)&MFDUSPEF)PMEFSXJUI 4UPSBHF4MFFWFBOEPOF$POEVDUJWJUZ$FMMBOE%01SPCF)PMEFS STARA-ESPH 0SJPO4UBS"4FSJFTQ)&MFDUSPEF)PMEFSGPS.FUFS"SNPS SFRVJSFTQ)TUPSBHFTMFFWF QVSDIBTF TFQBSBUFMZ STARA-ESCD 0SJPO4UBS"4FSJFT$POEVDUJWJUZ$FMMBOE%01SPCF)PMEFSGPS.FUFS"SNPS 1010003 Orion Star A Series Power Adapter for Benchtop and Portable Meters 8102BNUWP 30446MUSB(MBTT3FGJMMBCMFQ)&MFDUSPEF 8302BNUMD 3044(MBTT3FGJMMBCMFQ)"5$5SJPEF 8157BNUMD 30443FGJMMBCMF&QPYZQ)"5$5SJPEF 8107UWMMD 3044(FMGJMMFE&QPYZQ)"5$5SJPEFXJUI.FUFS$BCMF 927005MD &QPYZ4UFFM"5$1SPCF 927007MD Stainless Steel ATC Probe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olarographic DO Probe with Calibration Sleeve 083010MD Polarographic DO Probe with Calibration Sleeve and 3 Meter Cable 083025MD 1PMBSPHSBQIJD%01SPCFXJUI$BMJCSBUJPO4MFFWFBOE.FUFS$BCMF 086030MD "65045*3%0#0%1SPCF 087010MD RDO Optical DO Probe with 3 Meter Cable 087020MD 3%00QUJDBM%01SPCFXJUI.FUFS$BCMF 087030MD 3%00QUJDBM%01SPCFXJUI.FUFS$BCMF 096019 4UJSSFS1SPCFGPS4UBS"4FSJFT#FODIUPQ.FUFST Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 37 This page intentionally left blank. 38 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Chapter 10 Meter Compliance Notice of Compliance This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance XJUIUIFJOTUSVDUJPONBOVBM NBZDBVTFJOUFSGFSFODFUPSBEJPDPNNVOJDBUJPOT*UIBTCFFOUFTUFEBOEGPVOEUPDPNQMZ XJUIUIFMJNJUTGPSB$MBTT"DPNQVUJOHEFWJDFQVSTVBOUUP4VCQBSU+PG1BSUPG'$$3VMFT XIJDIBSFEFTJHOFEUP provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. i5IJTEJHJUBMBQQBSBUVTEPFTOPUFYDFFEUIF $MBTT" MJNJUTGPSSBEJPOPJTFFNJTTJPOTGSPNEJHJUBMBQQBSBUVTTFUPVUJO UIF3BEJP*OUFSGFSFODF3FHVMBUJPOTPGUIF$BOBEJBO%FQBSUNFOUPG$PNNVOJDBUJPOTw i-FQSFTFOUBQQBSFJMOVNFSJRVFOFNFUQBTEFCSVJUTSBEJPFMFDUSJRVFTEFQBTTBOUMFTMJNJUFTBQQMJDBCMFTBVYBQQBSFJMT OVNFSJRVFT EFMBDMBTT" QSFTDSJUFTEBOTMF3FHMFNFOUTVSMFCSPVJMMBHFSBEJPFMFDUSJRVFFEJDUFQBSMFNJOJTUFSFEFT $PNNVOJDBUJPOTEV$BOBEBw WEEE Compliance 5IJTQSPEVDUJTSFRVJSFEUPDPNQMZXJUIUIF&VSPQFBO6OJPOT8BTUF&MFDUSJDBM&MFDUSPOJD&RVJQNFOU 8&&& %JSFDUJWF&$*UJTNBSLFEXJUIUIFTZNCPMPOUIFMFGU 5IFSNP'JTIFS4DJFOUJmDIBTDPOUSBDUFEXJUIPOFPSNPSFSFDZDMJOHEJTQPTBMDPNQBOJFTJOFBDI&6.FNCFS4UBUFBOE this product should be disposed of or recycled through them. Further information on compliance with these directives, the recyclers in your country, and information on Thermo Scientific Orion products that may assist the detection of TVCTUBODFTTVCKFDUUPUIF3P)4%JSFDUJWFBSFBWBJMBCMFBUXXXUIFSNPTDJFOUJmDDPN Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 39 Declaration of Conformity Manufacturer: Thermo Fisher Scientific Inc. Address: Ayer Rajah Crescent #ML 4JOHBQPSF Singapore Hereby declares that the following products: #FODIUPQNFUFSTBSFSBUFEUP7"$ )[ " )BOEIFMENFUFSTVTFGPVSOPOSFDIBSHFBCMF""CBUUFSJFT Benchtop Meters Portable Meters 0SJPO4UBS"Q) 0SJPO4UBS"Q) Orion Star A212 Conductivity Orion Star A222 Conductivity Orion Star A213 RDO/DO Orion Star A223 RDO/DO 0SJPO4UBS"Q)*4& 0SJPO4UBS"Q) 0SJPO4UBS"Q)$POEVDUJWJUZ Orion Star A322 Conductivity 0SJPO4UBS"Q)3%0%0 Orion Star A323 RDO/DO 0SJPO4UBS"Q)*4& 0SJPO4UBS"Q)$POEVDUJWJUZ 0SJPO4UBS"Q)3%0%0 0SJPO4UBS"Q)*4&$POEVDUJWJUZ3%0%0 Equipment Class: Measurement, control and laboratory 0SJPO4UBS"TFSJFTNFUFSTBSF&.$$MBTT" Conforms with the following directives and standards: EN61326-1:2006 Electromagnetic Compatibility (EMC Directive) &MFDUSJDBMFRVJQNFOUGPSNFBTVSFNFOU DPOUSPMBOEMBCPSBUPSZVTF&.$SFRVJSFNFOUT EN61010-1:2001 Safety Standards UL61010-1:2004 Safety requirements for electrical equipment for measurement, CAN/CSA C22.2 No. 61010-1-04 DPOUSPMBOEMBCPSBUPSZVTFHFOFSBMSFRVJSFNFOUT $IFPX,XBOH$IBO QA/Regulatory Manager 40 1MBDFBOE%BUFPG*TTVF +VOF Singapore Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Meter Specifications Meter Operating Conditions Operating Ambient Temperature UP¡$ 0QFSBUJOH3FMBUJWF)VNJEJUZ UP OPODPOEFOTJOH Storage Temperature UP ¡$ 4UPSBHF3FMBUJWF)VNJEJUZ UP OPODPOEFOTJOH Pollution Degree 2 Overvoltage $BUFHPSZ** Weight 1PSUBCMFH #FODIUPQH Size 1PSUBCMFDN ) YDN 8 YDN % #FODIUPQDN ) YDN 8 YDN % Regulatory and Safety $& 567 '$$$MBTT" Power Rating %$*OQVU7%$" #BUUFSZY"" 4IPDLBOE7JCSBUJPO 7JCSBUJPOTIJQQJOHIBOEMJOHQFS*45"" 4IPDLESPQUFTUJOQBDLBHJOHQFS*45"" &ODMPTVSF EFTJHOFEUPNFFU 1PSUBCMF*1 #FODIUPQ*1 Warranty 3 year meter replacement Universal Power Adapter Operating Conditions Operating Ambient Temperature UP¡$ 0QFSBUJOH3FMBUJWF)VNJEJUZ UP OPODPOEFOTJOH Storage Temperature UP ¡$ 4UPSBHF3FMBUJWF)VNJEJUZ UP OPODPOEFOTJOH Pollution Degree 2 Overvoltage $BUFHPSZ** Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 41 Meter Parameter Specifications Dissolved Oxygen Measurement Concentration - Polarographic Range UPNH- Resolution Relative Accuracy % Saturation - Polarographic Range UPTBU Resolution Relative Accuracy Concentration - RDO Range UPNH- Resolution Relative Accuracy NH-VQUPNH- NH-GSPNUPNH- PGSFBEJOHGSPNUPNH- % Saturation - RDO 42 Range UPTBU Resolution Relative Accuracy Automatic Barometric Pressure Correction UPNN)H Salinity Factor Correction .BOVBMUPQQU Calibration Features 8BUFSTBUVSBUFEBJS BJSTBUVSBUFEXBUFS NBOVBM 8JOLMFS BOE[FSPQPJOU Probe Characteristics Polarographic or RDO Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Temperature Measurement Range UP¡$ Resolution Relative Accuracy Offset Calibration 1 point Data Logging /VNCFSPG1PJOUT 4UBS"XJUIUJNFBOEEBUFTUBNQ 4UBS"XJUIUJNFBOEEBUFTUBNQ 4UBS"XJUIUJNFBOEEBUFTUBNQ -PH'VODUJPO 4UBS".BOVBM 3FBEZ "6503&"% 5JNFE 4UBS".BOVBM "VUPNBUJDXJUI"6503&"% 4UBS".BOVBM 3FBEZ "6503&"% 5JNFE -PH&EJU Star A213: Delete individual points, group of points or all Star A223: Delete last reading or all Star A323: Delete individual points, group of points or all Inputs %0XJUI#VJMUJO5FNQFSBUVSF Probe Output QJO.JOJ%*/ 34 64# Power AC Adapter 6OJWFSTBM 7"$ JODMVEFEXJUI4UBS" Battery Power 'PVS"MLBMJOF"" JODMVEFEXJUI4UBS"BOE4UBS" #BUUFSZ-JGF IPVST Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 43 This page intentionally left blank. 44 Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide Appendix 1 Advanced Meter Features Dissolved Oxygen Barometric Pressure Compensation 5IF0SJPO4UBS"BOE4UBS"TFSJFT3%0%0NFUFSTIBWFBOJOUFSOBMCBSPNFUFSUIBUJTVTFEGPSQSFTTVSF compensated dissolved oxygen readings. The meter can also use manual barometric pressure compensation if dissolved oxygen is measured with a submerged probe or in a pressurized vessel. The pressure must be entered BTNN)H 1 mm Hg = 0.03937 inch Hg = 1.3332 hPa (mBar) = 0.01934 PSI. Dissolved Oxygen Salinity Correction "VUPNBUJDTBMJOJUZDPSSFDUJPOGPSEJTTPMWFEPYZHFOSFBEJOHTSFQPSUFEBTNH-JTBWBJMBCMFPOUIF0SJPO4UBS"Q) *4&DPOEVDUJWJUZ3%0%0NFUFSUIBUIBTCPUIEJTTPMWFEPYZHFOBOEDPOEVDUJWJUZNFBTVSFNFOUNPEFT5IFNFUFSVTFT the conductivity value read by the conductivity cell to calculate the salinity correction factor and applies the factor to EJTTPMWFEPYZHFOSFBEJOHTSFQPSUFEBTNH- .BOVBMTBMJOJUZDPSSFDUJPODBOCFVTFEGPSEJTTPMWFEPYZHFOSFBEJOHTSFQPSUFEBTNH-POBMM0SJPO4UBS" BOE4UBS"TFSJFT3%0%0NFUFST5IFNBOVBMTBMJOJUZDPSSFDUJPOGBDUPSNVTUCFFOUFSFEBTQQU QBSUTQFSUIPVTBOE Conductivity at 20 °C (mS/cm) Salinity Correction Value (ppt) Conductivity at 20 °C (mS/cm) Salinity Correction Value (ppt) Conductivity at 20 °C (mS/cm) Salinity Correction Value (ppt) 8 11 12 13 18 3 8 8 11 12 13 21 22 23 28 31 32 33 13 18 18 21 22 22 23 38 28 32 33 38 5IJTUBCMFXBTDBMDVMBUFEGSPNUIF*OUFSOBUJPOBM0DFBOPHSBQIJD5BCMFT 7PM /BUJPOBM*OTUJUVUFPG0DFBOPHSBQIZPG (SFBU#SJUBJO 8PNMFZ (PEBNJOH 4VSSFZ &OHMBOEBOE6OFTDP 1BSJT Thermo Scientific Orion Star A213 Benchtop and Star A223 and Star A323 Portable RDO/DO Meter Reference Guide 45 This page intentionally left blank. Water Analysis Instruments North America 166 Cummings Center Beverly, MA 01915 USA Toll Free: 1-800-225-1480 Tel: 1-978-232-6000 info.water@thermo.com Netherlands Tel: (31) 033-2463887 info.water.uk@thermo.com India Tel: (91) 22-4157-8800 wai.asia@thermofisher.com Japan Tel: (81) 045-453-9175 wai.asia@thermofisher.com China Tel: (86) 21-68654588 wai.asi@thermofisher.com Singapore Tel: (65) 6778-6876 wai.asia@thermofisher.com Australia Tel: (613) 9757-4300 in Australia (1300) 735-296 InfoWaterAU@thermofisher.com www.thermoscientific.com/water © 2011 Thermo Fisher Scientific Inc. All rights reserved. 68X576703 RevA 10-11 9001:2008
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : zachary.denadel Create Date : 2011:10:19 15:29:31-04:00 Modify Date : 2012:02:10 10:36:57-07:00 Subject : Thermo Scientific Orion Star A213, A223, A323 Reference Guide Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Metadata Date : 2012:02:10 10:36:57-07:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 6747 bytes, use -b option to extract), (Binary data 5121 bytes, use -b option to extract) Instance ID : uuid:aa968a19-7d24-4e46-99db-af282ef40b79 Document ID : xmp.did:924BF5A476FAE011AA93E958C0635579 Original Document ID : adobe:docid:indd:c7d35728-36f8-11de-81b5-8a9eac58996b Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:8F4BF5A476FAE011AA93E958C0635579 Derived From Document ID : xmp.did:3C7E39D366FAE011B0A6DD362E0B631B Derived From Original Document ID: adobe:docid:indd:c7d35728-36f8-11de-81b5-8a9eac58996b Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:BA65AA2D6260E01184488A75A91CB063, xmp.iid:BB65AA2D6260E01184488A75A91CB063, xmp.iid:BE65AA2D6260E01184488A75A91CB063, xmp.iid:BF65AA2D6260E01184488A75A91CB063, xmp.iid:3EE2351F6460E01184488A75A91CB063, xmp.iid:41E2351F6460E01184488A75A91CB063, xmp.iid:42E2351F6460E01184488A75A91CB063, xmp.iid:45E2351F6460E01184488A75A91CB063, xmp.iid:B56E46466760E01184488A75A91CB063, xmp.iid:B86E46466760E01184488A75A91CB063, xmp.iid:B96E46466760E01184488A75A91CB063, xmp.iid:BC6E46466760E01184488A75A91CB063, xmp.iid:B1DBC2F97360E01184488A75A91CB063, xmp.iid:B2DBC2F97360E01184488A75A91CB063, xmp.iid:B3DBC2F97360E01184488A75A91CB063, xmp.iid:B6DBC2F97360E01184488A75A91CB063, xmp.iid:B9DBC2F97360E01184488A75A91CB063, xmp.iid:B23082848460E01184488A75A91CB063, xmp.iid:AD219ECA8960E01189A5E1F8C363F751, xmp.iid:AE219ECA8960E01189A5E1F8C363F751, xmp.iid:B1219ECA8960E01189A5E1F8C363F751, xmp.iid:434E6C33E265E0118E46C7FFDA2D9DEB, xmp.iid:F21E6052E965E0118E46C7FFDA2D9DEB, xmp.iid:D405FD502466E011B770AF1006B5049B, xmp.iid:7666BEF8026AE01196309CF9B90E90F4, xmp.iid:712651110A6AE01196309CF9B90E90F4, xmp.iid:7A4B4BCB4D6CE011BF47F1D79D7ACB48, xmp.iid:7B4B4BCB4D6CE011BF47F1D79D7ACB48, xmp.iid:7E4B4BCB4D6CE011BF47F1D79D7ACB48, xmp.iid:DF2113FF526CE011BF47F1D79D7ACB48, xmp.iid:6663016B1070E011A116A9C9D78DC767, xmp.iid:6963016B1070E011A116A9C9D78DC767, xmp.iid:CB5102C3357BE01197688C96374368BB, xmp.iid:FB6BE0977B8CE011A34AFEADBABE2136, xmp.iid:FE6BE0977B8CE011A34AFEADBABE2136, xmp.iid:18BD26A3948CE011A34AFEADBABE2136, xmp.iid:1BBD26A3948CE011A34AFEADBABE2136, xmp.iid:1EBD26A3948CE011A34AFEADBABE2136, xmp.iid:D69AAD226690E0118C96A66D45408958, xmp.iid:0BA72B9FF9B9E011A0E99CEE79AA7397, xmp.iid:0EA72B9FF9B9E011A0E99CEE79AA7397, xmp.iid:005ED5E3FCB9E011A0E99CEE79AA7397, xmp.iid:CFADB69684F6E0118847BA0D004FDB00, xmp.iid:D2ADB69684F6E0118847BA0D004FDB00, xmp.iid:D3ADB69684F6E0118847BA0D004FDB00, xmp.iid:D6ADB69684F6E0118847BA0D004FDB00, xmp.iid:357E39D366FAE011B0A6DD362E0B631B, xmp.iid:387E39D366FAE011B0A6DD362E0B631B, xmp.iid:397E39D366FAE011B0A6DD362E0B631B, xmp.iid:3C7E39D366FAE011B0A6DD362E0B631B, xmp.iid:59497E3673FAE0119F8882407B772C4E, xmp.iid:8F4BF5A476FAE011AA93E958C0635579, xmp.iid:924BF5A476FAE011AA93E958C0635579 History When : 2011:04:06 11:26:01-04:00, 2011:04:06 11:26:01-04:00, 2011:04:06 11:37:54-04:00, 2011:04:06 11:37:54-04:00, 2011:04:06 11:39:55-04:00, 2011:04:06 11:39:55-04:00, 2011:04:06 11:42:58-04:00, 2011:04:06 11:42:58-04:00, 2011:04:06 12:02:29-04:00, 2011:04:06 13:12:50-04:00, 2011:04:06 13:27:49-04:00, 2011:04:06 13:27:49-04:00, 2011:04:06 13:33:24-04:00, 2011:04:06 13:34:10-04:00, 2011:04:06 13:36:47-04:00, 2011:04:06 13:41:21-04:00, 2011:04:06 13:41:28-04:00, 2011:04:06 15:32:26-04:00, 2011:04:06 16:09:34-04:00, 2011:04:06 16:53:16-04:00, 2011:04:06 16:53:16-04:00, 2011:04:13 11:30:41-04:00, 2011:04:13 12:19:26-04:00, 2011:04:13 19:18:38-04:00, 2011:04:18 17:46:32-04:00, 2011:04:18 18:20:29-04:00, 2011:04:21 16:01:13-04:00, 2011:04:21 16:05:05-04:00, 2011:04:21 16:05:05-04:00, 2011:04:21 16:56:55-04:00, 2011:04:26 10:21:03-04:00, 2011:04:26 11:04:01-04:00, 2011:05:10 14:46:11-04:00, 2011:06:01 14:18:47-04:00, 2011:06:01 14:18:47-04:00, 2011:06:01 17:20:48-04:00, 2011:06:01 17:20:48-04:00, 2011:06:01 17:56:24-04:00, 2011:06:06 16:26:14-04:00, 2011:07:29 11:45:36-04:00, 2011:07:29 11:45:37-04:00, 2011:07:29 12:07:42-04:00, 2011:10:14 12:50:14-04:00, 2011:10:14 12:50:14-04:00, 2011:10:14 12:50:57-04:00, 2011:10:14 12:52:35-04:00, 2011:10:19 12:35:17-04:00, 2011:10:19 12:35:17-04:00, 2011:10:19 12:37:25-04:00, 2011:10:19 12:37:25-04:00, 2011:10:19 12:55:56-04:00, 2011:10:19 13:20:30-04:00, 2011:10:19 13:20:30-04:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata Doc Change Count : 171 Format : application/pdf Creator : zachary.denadel Title : RG-68X576703_RevA_HIRES_10_11.pdf Description : Thermo Scientific Orion Star A213, A223, A323 Reference Guide Producer : Acrobat Distiller 9.4.5 (Windows) Trapped : False Page Count : 52EXIF Metadata provided by EXIF.tools