PARABOLICS / P4222.INDD
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
Page 1/2 Rev. 05/22/17
EXAMPLE P422-217G-LD33-S-EUORDERING INFORMATION
SIZE
22 2' × 2'
NO. OF LAMPS
2Two
CONSTRUCTION
Luminaire housing and end caps are die formed
code gauge cold rolled steel. Louver is formed from
low iridescent anodized aluminum and is secured by
die-formed spring steel hinges. Louver hinges from
either side. Mechanical light trap prevents light
leaks. Latches are nger-tip actuated, positive feed
type and completely concealed in the black reveal.
FINISH
Painted parts are treated with a ve stage
phosphate bonding process and nished with a high
temperature baked white enamel. Louvers are low
iridescent semi-specular (diuse) natural anodized
(LD) aluminum as standard.
AIR HANDLING
All supply/return and air extract functions are
shown on the specication sheet and are available
as a specied option. Specify air handling
requirement by including function number as part
of complete catalog number. Directional control
vanes and/or extract dampers must be specied. Air
extract slots are located out of sight in end caps. See
air removal data on specication sheet.
INSTALLATION
For fast wiring connections without the necessity of
opening xture or wireway, a ex connector adapter
plate is furnished with each luminaire. A plastic
dust cover which eliminates construction dust and
protects the lamps is provided as standard.
BALLASTS
Energy ecient, thermally protected, automatic
resetting, Class P, high power factor, sound rated A,
magnetic or electronic ballasts. CEE NEMA Premium
compliant.
ELECTRICAL
Standard class “P, thermally protected,
autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CEC-
compliant ballast disconnect is standard.
CEILING COMPATIBILITY
Luminaire is available to t most standard ceiling
types. NEC-compliant tee-bar clips supplied
with all grid trim xtures. See ceiling details on
reverse. Contact your Columbia representative for
compatibility information for specic ceiling types.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
xtures labeled UL 924.
LAMP TYPE
31U1 U-Bent, 1⁄" Leg
Spacing T8: 31 Watt
17 2', T8: 17 Watt
32U6 U-Bent, 6" Leg
Spacing T8: 32 Watt
40TT Twin Tube Compact,
2G11 Base: 40 Watt
3" Deep Louver
FEATURES
3" deep cell parabolic louver for optimum control
IES standard RP-1 glare control models available
Wide light distribution provides uniform illumination
Black reveal with full air handling capabilities
Anodized low iridescent aluminum louver
Treated with a ve stage phosphate bonding process and
nished with a baked white enamel
Mechanical light trap prevents light leaks
BALLAST
EElectronic T8, Instant Start
EP Electronic T5 or T8,
Programmed Start
EPTT Electronic Twin Tube,
Programmed Start (40TT)
For a specific ballast vendor, show
as option.
Also available with 3 lamps and 16 cells
– –
22 2
P4 – –
MODEL
P4 Recessed
Air Handling
Parabolic
CEILING TYPE
GGrid
FOverlap Flange
MModular Fit-in Trim
SG Slot Grid
NO. CELLS
LENGTHWISE
3Three
4Four
NO. CELLS
CROSSWISE
3Three
4Four
LOUVER FINISH
LD Low Iridescent
Semi-Specular (Std.)
LS Low Iridescent Specular
MA Matte Anodized Low
Iridescent Semi-
Specular Aluminum
GW Gloss White Enamel
AIR FUNCTIONS
SStatic
AAir Handling
AV Air Handling w/Supply Vanes
CCombination Supply/Extract
CV Combination Supply
Vanes/Extract
CD Combination Supply
Extract Dampers
CVD Combination Supply
Vanes Extract Dampers
HHeat Extract
HD Heat Extract w/Dampers
VOLTAGE
U120V-277V
347 347V
OPTIONS1
GLR Fast Blow Fuse
GMF Slow Blow Fuse
EL Emergency Battery
Pack
C388 3-Wire Flex
C488 4-Wire Flex
MS9 Master/Satellite
w/9' Harness
NYC NYC Compliant
NYCU NYC Compliant, Union
Label
1 EL or other options may increase fixture depth.
P422-2
2' × 2' Recessed Air Handling Parabolic / 2-Lamp T8, TT, U-Bent
Catalog No.
Project Name Type
Date
PROJECT INFORMATION
PARABOLICS / P4222.INDD
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
Page 2/2 Rev. 05/22/17
Test L11171 Test Date 1/8/03
Zone Lumens % Lamp % Fixt.
0-30 1020 18.2 26.5
0-40 1737 31.0 45.1
0-60 3466 61.9 90.1
0-90 3849 68.7 100.0
0-180 3849 68.7 100.0
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
176 73 71 68 74 72 69 67 69 67 65 60
270 64 60 57 68 63 59 56 61 58 55 51
364 57 52 48 62 56 51 47 54 50 46 43
458 50 45 40 57 49 44 40 48 43 39 37
553 45 39 34 52 44 38 34 43 38 34 32
649 40 34 30 48 39 34 30 38 33 29 28
745 36 30 26 44 36 30 26 35 30 26 24
842 33 27 23 41 32 27 23 31 26 23 21
939 30 24 21 38 30 24 21 29 24 20 19
10 37 28 22 19 36 27 22 18 27 22 18 17
Luminaire
P422-231U1G-LD33-E-PAF
P4 Parabolic
2 × 2 2-Lamp T8U with White
Interior and 3 × 3 Cell Semi-
Specular Louver
Ballast SSB2-120-2/32IS LH
Ballast Factor 0.88
Lamp FBO31/31K
Lumens per Lamp 2800
Watts 55
Shielding Angle N/A
Spacing Criterion 0° = 1.28 90° = 1.71
Total Luminaire Eciency 68.7%
Luminaire Ecacy Rating (LER) 62
IESNA RP-1-1993 Compliance Noncompliant
IESNA RP-1-2004 Compliance Noncompliant
Comparative Yearly Lighting Energy
Cost per 1000 Lumens
$3.87 based on 3000 hrs.
and $0.08 per KWH
0.0 22.5 45.0 67.5 90.0
Average Luminance Angle
04315 4315 4315 4315 4315
30 4312 4479 4582 4685 4840
40 4301 4575 4817 5665 6373
45 4252 4529 5165 6516 7488
50 4126 4458 5650 7227 8183
55 3864 4277 5942 7236 8260
60 3395 3972 5367 5806 5923
65 2008 2780 3439 2634 1878
70 492 733 1045 563 512
75 252 305 305 332 319
80 119 158 178 198 198
85 0 39 79 118 79
0 15 20 40 60 80 100 200 400 600 800 1000
Air Flow Rate-CFM
Negative
Static
Pressure
-
Inches
of
Water
R1 -
Air Return thru One Side Passage
E -
Heat Extract thru Lamp Compartment
R2 -
Air Return thru Two Side Passages
ER2 -
Thru Both Sides and Lamp Compartment
R1 E R2 ER2
.10
.08
.06
.04
.02
.015
24
"
24
"
25¾
"
24
"
3
¾"
¼" Diuser
Mtg. K.O.
⁄
"
High Embossed
25¾
"
4
"
3
"
Side End Side End
Side End Side End
Type M
Type SG
CEILING COMPATIBILITY
For tile, plaster or plasterboard type
ceilings. Overlapping extruded
aluminum trim conceals edges
of ceiling opening. Wing hanger
suspension system included. For row
mounting, row information is required.
For metal pan ceilings “Fit-in style
extruded trim aligns with modular
tile joints. Fixture is supported with
concealed suspension and includes all
adjustable wing hangers.
For lay-in installation in exposed grid
ceilings. Maximum tee widths of 1" and
maximum tee heights of 112" allowed.
For ⁄" slot grid type ceilings. Louver
will be level with the ceiling plane.
Shoulder heights of tee or exact slot
grid must be specied.
Flange kit rough in dimensions for single unit only: 24⁄" × 24⁄"
DIMENSIONAL DATA
NOTE: All dimensions are in inches; dimensions and specications are
subject to change without notice. Please consult factory or check
sample for verication.
Type F
Type G
2" × 3"
F-Cap Hole
5
⁄"
PHOTO ME TRI C DATA
ZO NAL LU ME N SU MM ARY
COEFFICIENTS OF UTILIZATIO N (%) EXTR ACT AIR DATA
AVG. LUMINANCE
Candela/Sq. M.
ENERGY DATALUMINAIRE DATA INDOOR CANDELA PLOT
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Report AL-526-1.1
22⁄
"
1⁄
"
24⁄
"
10¾
"
⁄
"
.875 DIA K.O.
P422-2
2' × 2' Recessed Air Handling Parabolic / 2-Lamp T8, TT, U-Bent