P422-2 2' × 2' Recessed Air Handling Parabolic / 2-Lamp T8, TT, U-Bent PROJECT INFORMATION 3" Deep Louver Project Name Type Catalog No. Date CONSTRUCTION Luminaire housing and end caps are die formed code gauge cold rolled steel. Louver is formed from low iridescent anodized aluminum and is secured by die-formed spring steel hinges. Louver hinges from either side. Mechanical light trap prevents light leaks. Latches are finger-tip actuated, positive feed type and completely concealed in the black reveal. Also available with 3 lamps and 16 cells FEATURES • • • • • • 3" deep cell parabolic louver for optimum control IES standard RP-1 glare control models available Wide light distribution provides uniform illumination Black reveal with full air handling capabilities Anodized low iridescent aluminum louver Treated with a five stage phosphate bonding process and finished with a baked white enamel • Mechanical light trap prevents light leaks BALLASTS Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, magnetic or electronic ballasts. CEE NEMA Premium compliant. ELECTRICAL FINISH Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard. AIR HANDLING Luminaire is available to fit most standard ceiling types. NEC-compliant tee-bar clips supplied with all grid trim fixtures. See ceiling details on reverse. Contact your Columbia representative for compatibility information for specific ceiling types. Painted parts are treated with a five stage phosphate bonding process and finished with a high temperature baked white enamel. Louvers are low iridescent semi-specular (diffuse) natural anodized (LD) aluminum as standard. All supply/return and air extract functions are shown on the specification sheet and are available as a specified option. Specify air handling requirement by including function number as part of complete catalog number. Directional control vanes and/or extract dampers must be specified. Air extract slots are located out of sight in end caps. See air removal data on specification sheet. CEILING COMPATIBILITY CERTIFICATION All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. INSTALLATION For fast wiring connections without the necessity of opening fixture or wireway, a flex connector adapter plate is furnished with each luminaire. A plastic dust cover which eliminates construction dust and protects the lamps is provided as standard. ORDERING INFORMATION P4 22 MODEL – 2 – NO. OF LAMPS P4 Recessed Air Handling Parabolic 1 EXAMPLE P422-217G-LD33-S-EU 2 Two CEILING TYPE G F M SG Grid Overlap Flange Modular Fit-in Trim Slot Grid – NO. CELLS NO. CELLS CROSSWISE LENGTHWISE 3 Three 4 Four SIZE LAMP TYPE LOUVER FINISH 22 2' × 2' 31U1 U-Bent, 15⁄8" Leg Spacing T8: 31 Watt 17 2', T8: 17 Watt 32U6 U-Bent, 6" Leg Spacing T8: 32 Watt 40TT Twin Tube Compact, 2G11 Base: 40 Watt LD Low Iridescent Semi-Specular (Std.) LS Low Iridescent Specular MA Matte Anodized Low Iridescent SemiSpecular Aluminum GW Gloss White Enamel EL or other options may increase fixture depth. Page 1/2 Rev. 05/22/17 3 Three 4 Four – – BALLAST OPTIONS1 E Electronic T8, Instant Start EP Electronic T5 or T8, Programmed Start EPTT Electronic Twin Tube, Programmed Start (40TT) For a specific ballast vendor, show as option. GLR Fast Blow Fuse GMF Slow Blow Fuse EL Emergency Battery Pack C388 3-Wire Flex C488 4-Wire Flex MS9 Master/Satellite w/9' Harness NYC NYC Compliant NYCU NYC Compliant, Union Label AIR FUNCTIONS S A AV C CV CD CVD H HD Static Air Handling Air Handling w/Supply Vanes Combination Supply/Extract Combination Supply Vanes/Extract Combination Supply Extract Dampers Combination Supply Vanes Extract Dampers Heat Extract Heat Extract w/Dampers VOLTAGE U 120V-277V 347 347V PARABOLICS / P422-2.indd © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com P422-2 2' × 2' Recessed Air Handling Parabolic / 2-Lamp T8, TT, U-Bent PHOTOMETRIC DATA Test L11171 Test Date 1/8/03 LUMINAIRE DATA INDOOR CANDELA PLOT ENERGY DATA P422-231U1G-LD33-E-PAF P4 Parabolic 2 × 2 2-Lamp T8U with White Interior and 3 × 3 Cell SemiSpecular Louver SSB2-120-2/32IS LH 0.88 FBO31/31K 2800 55 N/A 0° = 1.28 90° = 1.71 Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Lumens % Lamp % Fixt. 0-30 0-40 0-60 0-90 0-180 1020 1737 3466 3849 3849 18.2 31.0 61.9 68.7 68.7 26.5 45.1 90.1 100.0 100.0 RCR COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10 70 76 70 64 58 53 49 45 42 39 37 80 50 30 73 71 64 60 57 52 50 45 45 39 40 34 36 30 33 27 30 24 28 22 10 68 57 48 40 34 30 26 23 21 19 70 74 68 62 57 52 48 44 41 38 36 70 50 30 72 69 63 59 56 51 49 44 44 38 39 34 36 30 32 27 30 24 27 22 EXTRACT AIR DATA 10 67 56 47 40 34 30 26 23 21 18 50 69 61 54 48 43 38 35 31 29 27 50 30 67 58 50 43 38 33 30 26 24 22 68.7% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 62 Noncompliant Noncompliant $3.87 based on 3000 hrs. and $0.08 per KWH AVG. LUMINANCE (Candela/Sq. M.) ZONAL LUMEN SUMMARY Zone Total Luminaire Efficiency Average Luminance Angle Luminaire 10 65 55 46 39 34 29 26 23 20 18 0.0 22.5 45.0 67.5 90.0 4315 4312 4301 4252 4126 3864 3395 2008 492 252 119 0 4315 4479 4575 4529 4458 4277 3972 2780 733 305 158 39 4315 4582 4817 5165 5650 5942 5367 3439 1045 305 178 79 4315 4685 5665 6516 7227 7236 5806 2634 563 332 198 118 4315 4840 6373 7488 8183 8260 5923 1878 512 319 198 79 Report AL-526-1.1 .10 0 0 60 51 43 37 32 28 24 21 19 17 0 30 40 45 50 55 60 65 70 75 80 85 .08 Negative Static Pressure Inches of Water .06 R1 E R2 ER2 .04 .02 .015 0 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 15 20 40 R1 - Air Return thru One Side Passage R2 - Air Return thru Two Side Passages DIMENSIONAL DATA 60 80 100 200 Air Flow Rate-CFM 400 600 800 1000 E - Heat Extract thru Lamp Compartment ER2 - Thru Both Sides and Lamp Compartment CEILING COMPATIBILITY Type SG Type G 53⁄8" 3" 4" Side 24" 33⁄4" For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 11⁄2" allowed. 253⁄4" 24" End ¼" Diffuser Mtg. K.O. 3⁄16" High Embossed 2" × 3" F-Cap Hole Side End For 9⁄16" slot grid type ceilings. Louver will be level with the ceiling plane. Shoulder heights of tee or exact slot grid must be specified. Type M Type F 24" 253⁄4" 221⁄8" Side End For tile, plaster or plasterboard type ceilings. Overlapping extruded aluminum trim conceals edges of ceiling opening. Wing hanger suspension system included. For row mounting, row information is required. .875 DIA K.O. 29⁄32" Side End For metal pan ceilings “Fit-in” style extruded trim aligns with modular tile joints. Fixture is supported with concealed suspension and includes all adjustable wing hangers. Flange kit rough in dimensions for single unit only: 241/8" × 241/8" 103⁄4" 243⁄8" Page 2/2 Rev. 05/22/17 17⁄16" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. PARABOLICS / P422-2.indd © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com