GE Consumer & Industrial

Service Bulletin
REFRIGERATION
ACME FITTINGS, FILTER,
DRIER AND CHARGING VALVE

GE Appliances
General Electric Company
Louisville, Kentucky 40225

REF 09-04

MAY 2004

ELIMINATION OF ACME FITTINGS AND FILTER CHANGES
Effective in 2004, ACME fittings are no longer
required when making a repair on R134a
refrigerant systems.
Improvements in refrigerant oil and system
design over the years has shown the danger
of cross-contamination from using the same
hoses to be minimal. All fittings for refrigeration repair will be converted to 1/4" SAE as
inventory of ACME fittings is depleted.
Although R134a and R12 will share a common
fitting size, care must still be taken to prevent
cross-contamination of recovery cylinders.
Label charging and recovery cylinders appropriately and follow all refrigeration and safety
procedures.
A new “drier only” design is available for most
refrigeration sealed system repairs.

For these repairs, the installation of a filter
drier (WR86X96) with extra filtering capacity
is required.
WR86X96

When installing the WR86X96 filter drier, add
an additional 1/2 ounce to the quantity
stated on the name plate to compensate for
the additional volume of the filter.

WJ56X61

WR86X93

When installing the WR86X93 drier, recharge
the system with the exact refrigerant charge
stated on the name plate.

The charging valve (WJ56X61) should be
used at the compressor process tube for
charging the system.

The installation of only a drier (WR86X93) is
approved for all sealed system repairs except
in the following situations:
1. Replacing a rotary compressor
2. Compressor burn-out
3. When known contaminates have entered
the system.
GE CONFIDENTIAL AND PROPRIETARY INFORMATION–NOT FOR PUBLIC DISCLOSURE
N.D. 918-09



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a8ce420b-4e48-4cd1-8355-2f94ff55ebd8
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2004:06:22 11:47:15-04:00
Create Date                     : 2004:06:22 11:47:15-04:00
Document ID                     : uuid:f650a3d9-9ce1-4d31-8d2b-52324dcdd905
Format                          : application/pdf
Title                           : REF09-04.pdf
Creator                         : 214000321
Author                          : 214000321
EXIF Metadata provided by EXIF.tools

Navigation menu