RSA B CENB Spec Sheet
2017-10-24
: Pdf Rsa B Cenb Spec Sheet RSA_B_CENB_spec_sheet spec products beacon
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
RSA-B-CENB SERIES POLES Cat.# Type Job Approvals ROUND STRAIGHT ALUMINUM APPLICATIONS • Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum allowable loading of the specified pole in its installed geographic location CONSTRUCTION • SHAFT: One-piece straight aluminum with fluted or smooth cross section; Extruded shafts of 6061-T6 aluminum in 3/16” or 1/4” thickness. Decorative base of 356 cast aluminum. • POLE CAP OR FINALS: Cap or decorative finials available for side mounted luminaires. Open top or tenons provided for post top mounted luminaires. • HAND HOLE: Hand hole provided in cast base; Mounting provisions for grounding lug located behind cover • ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). Galvanized hardware with two washers and two nuts per bolt for leveling FINISH • Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness • Powder paint finish coat available in twelve standard colors; Custom colors available; RAL number preferable. 5” Diameter 19.5” BASE DETAIL TENONS & POLE CAPS 19.5” DECORATIVE BASE WASHER LEVELING NUT ANCHOR BOLT PROJECTION Bolt Circle 12.5” FOUNDATION / FOOTING (BY OTHERS) ORDERING EXAMPLE: S/F RSA-B-CENB 16 50 SERIES STYLE HEIGHT SHAFT RSA-B- Round Straight CENB Aluminum Pole S Smooth F Fluted Reference page 2 Ordering 11 matrix Reference page 2 Ordering 2L 2L2 matrix Beacon 1 12L 1 2 23Y3T 2L 23T 3T4 3Y 3T 4 3Y 22 2L MOUNTING ORIENTATION 122L 1 3Y 3Y 3T 3T Description 2nd mode vibration damper Denotes handhole location Denotes handhole location B3 MOUNTING 1 Single arm mount 2 Two fixtures at 180˚ 2L Two fixtures at 90˚ 3T Three fixtures 44 FINISH DB Dark Bronze Textured BL Black Textured B1 Cruzer B3 VP-L B4 VP-S 3Y Three at 120˚ 4 Four fixtures at 90˚ OT Open top (includes pole cap) TN3 TN4 TN5 TN8 ARC BAL CAP DBT DRILL PATTERN at 90˚ 4 Denotes Denoteshandhole handholelocation location 3Y 4 4 DenotesDenotes handhole locationlocation handhole ACCESSORIES- Order Separately 2L THICKNESS 2L Reference page 2 Ordering matrix 3T Denotes handhole location 3Y Catalog Number VM2SXX A/B/C VM2 OPTIONS GFI1 20 Amp GFCI Receptacle and Cover WH White Textured PS Platinum Silver EHH1 Extra Handhole GYS Light Gray Smooth BZT Bronze Textured C071 .75” Coupling BBT Basic Black Textured CC Custom Color Tenon 3 x 3 Tenon 3 x 4 C051 .5” Coupling C201 2” Coupling VM2 2nd mode vibration damper LAB Less Anchor Bolts Tenon 4 x 5 Tenon 4 x 8 Acorn Finial Ball Finial Cap 1 Specify option location using logic found on page 2 (Option Orientation) Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. © 2016 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC October 18, 2017 11:11 AM ORDERING INFORMATION Cont. Height Catalog Number RSA-B-CENB-S-10-50-B RSA-B-CENB-S-12-50-B RSA-B-CENB-S-14-50-B RSA-B-CENB-S-16-50-B RSA-B-CENB-S-18-50-B RSA-B-CENB-S-20-50-B RSA-B-CENB-S-22-50-B RSA-B-CENB-S-24-50-B Feet Meters Nominal Shaft Dimensions Wall Thickness Bolt Circle (suggested) Bolt Square Base Plate Size Anchor Bolt Size Bolt Projection Pole weight (lbs) 10 3.0 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 85 12 14 16 18 20 22 24 3.7 4.3 4.9 5.5 6.1 6.7 7.3 5" Round 5" Round 5" Round 5" Round 5" Round 5" Round 5" Round 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 92 98 105 112 118 125 132 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 94 103 111 120 129 138 146 155 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 8.84" 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3/4 x 30 x 4 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 3-1/2" 86 93 100 107 113 120 127 134 Anchor Base Detail RSA-B-CENB-S-10-50-C RSA-B-CENB-S-12-50-C RSA-B-CENB-S-14-50-C RSA-B-CENB-S-16-50-C RSA-B-CENB-S-18-50-C 90° Arm 2 RSA-B-CENB-S-20-50-C RSA-B-CENB-S-22-50-C RSA-B-CENB-S-24-50-C 10 3.0 5" Round 12 3.7 5" Round 14 180° 4.3 Bolt Slots/Holes 5" Round 16 4.9 Bolt Circle5" Round viewed 18 Asfrom 5.5 270° 5" Round 90° top of pole. Arm 1 Arm 2 20 6.1 5" Round 22 6.7 5" Round 24Bolt Square7.30°-Handhole5" Round 10 RSA-B-CENB-F-10-50-B 12 RSA-B-CENB-F-12-50-B 14 RSA-B-CENB-F-14-50-B Anchor Base Detail 16 RSA-B-CENB-F-16-50-B 18 RSA-B-CENB-F-18-50-B 180° 20 RSA-B-CENB-F-20-50-BBolt Slots/Holes Bolt Circle 22 RSA-B-CENB-F-22-50-B 90° 270° Arm 2 Arm 1 24 RSA-B-CENB-F-24-50-B As viewed from top of pole. 3.0 3.7 4.3 4.9 5.5 6.1 6.7 90° Arm 2 7.3 180° As viewed from top of pole. 5" Fluted 5" Fluted 5" Fluted 5" Fluted 5" Fluted Bolt Slots/Holes 5" Fluted Bolt Circle 5" Fluted 270° Arm 1 5" Fluted 0.25" 0.25" 180° 0.25" 0.25" As viewed 0.25" from top of pole. 0.25" 0.25" 0.25" Bolt Square 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" 12-1/2" 12-1/2" 12-1/2" Bolt Slots/Holes Bolt Circle 12-1/2" 12-1/2" 270° Arm 1 12-1/2" 12-1/2" 0°-Handhole 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" 12-1/2" NOTE Factory supplied template must be used when setting anchor bolts. Hubbell Lighting will deny any claim for incorrect anchorage placement resulting from failure to use factory supplied template and anchor bolts. 0°-Handhole 0°-Handhole Bolt Square EHH - EXTRA HANDHOLE Bolt Square BASE COVER C05 - C07 - C20 - COUPLING VM2 - VIBRATION DAMPER 2ND MODE GFI – 20 AMP GFCI RECEPTACLE & COVER Round Steel Pole 2” -11.5 NPSM Threads Factory installed, internal damper designed to alter pole resonance to reduce movement and material fatigue caused by 2nd mode vibration. 3/4” - 14 NPSM Overall Threads Height 10'-30' 1/2” - 14 NPSM Threads Provision for Grounding OPTION ORIENTATION Follow the logic below when ordering location specific options. For each 18" its height (in feet). Example: option, include its orientation (in degrees) and Option C07 should be ordered as: RSA-CENB-F-16-50-B-TN3-DBT (.5” coupling on the handhole/arm side of pole, 15 feet up from the pole base) 1’ spacing required between option. Consult factory for other configurations. VM2SXX - VIBRATION DAMPER 2ND MODE Standard hand hole frame Adapter plate Gasket VIBRATION DAMPER VM2S08 – 8' 2ND MODE VM2S12 – 12' VM2S16 – 16' Field installed, internal damper VM2S20 – 20' designed to alter pole resonance VM2S24 – 24' to reduce movement and mateHeight of option in feet rial fatigue caused by 2nd mode vibration. 20 AMP GFCI Wet Locations In-use Cover Bolt Square (Outer) For more information about pole vibration and vibration dampers, please consult http://cdn.spauldinglighting.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf Bolt Square Due to our continued efforts to 0˚improve our (Inner) products, product specifications are subject to change without notice. Handhole Bolt Circle (Outer) 90˚ 270˚ Bolt Circle (Inner) 180˚ TENON Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. © 2016 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC October 18, 2017 11:11 AM ASCE7-05 WIND MAP 130 140 90 100 110 120 85 130 90 Wind Map Special Wind Region NOTES: • Values are based on 50 year mean recurrence interval 30’ above grade. • Hawaii has an 105 mph wind velocity. *PRINTED WITH PERMISSION FROM ASCE • Puerto Rico has a 125 mph wind velocity. • Caution must be exercised in determining wind velocities in special wind areas such as: Mountainous Regions Areas surrounding the Great Lakes or other large bodies of water or open land. Areas subject to extreme wind conditions, such as hurricanes, typhoons, cyclones, and tornadoes. Areas adjacent to airports. Any specific area with a known or suspected abnormally high intermittent wind condition caused by geography, adjacent structures, othermap specific localLoad conditions ASCE 7-05 or wind EPA Rating that may not be recorded in National Weather Service records. Catalog Number 85 90 100 105 • Allowable pole EPA for jobsite wind conditions must be equal to or greater than fixture25.0 EPA. Responsibility with 25.0 20.3lies 18.5 RSA-B-CENB-S-10-50-B the specifier for correct pole selection based on AASHTO RSA-B-CENB-S-12-50-B wind map and job location. 21.7 19.3 15.6 14.2 140 140 150 140 • Florida region wind map above is based upon 3-second gust winds and the 2014 Florida Building Code 160 150 170 160 ALASKA REGION WIND MAP 140 120 90 140 100 130 110 120 130 120 170 140 150 HAWAII – 105 mph PUERTO RICO – 145 mph 150 United States and Canada 140 (Consult Local Authorities) 115 150 130 90 FLORIDA REGION WIND MAP 115 120 150 180 180 110 100 90 130 • The Wind Map is intended only as a general guide. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application. • CAUTION: Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this general guide. Consult AASHTO standards. • Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or Tornadoes expose poles to flying debris, 130 wind shear, and other unpredictable aerodynamic forces not indicated by the wind velocity ratings. 130 • Pole Strength Limited Warranty: Standard, unmodified Kim lighting Poles installed as recommended, undamaged by corrosion, or lack of maintenance, shall withstand steady 3 second gust wind speeds Florida Building Code wind conditions as provided on page 2 (Allowable Pole EPA). Installation of poles without luminaires, or attachment 110of any120 130 accessories 140 145 150shall void this Catalog Number unauthorized to poles warranty. 16.9 14.2 12.1 10.4 9.7 9.1 RSA-B-CENB-S-10-50-B 90 130 100 110 120 2014 EPA Load Rating - 3 second gust wind speeds 115 120 130 140 150 160 170 180 21.0 19.3 16.3 14.7 12.7 11.1 9.8 8.6 12.9 10.8 9.2 7.9 7.3 6.8 RSA-B-CENB-S-12-50-B 16.1 14.7 12.3 11.3 9.8 8.4 7.3 6.4 RSA-B-CENB-S-14-50-B 17.2 15.2 12.2 11.1 10.1 8.4 7.1 6.1 5.7 5.3 RSA-B-CENB-S-14-50-B 12.5 11.4 9.4 8.9 7.6 6.5 5.6 4.8 RSA-B-CENB-S-16-50-B 13.9 12.2 9.7 8.8 8.0 6.6 5.6 4.7 4.4 4.1 RSA-B-CENB-S-16-50-B 9.7 8.7 7.0 6.5 5.9 5.0 4.2 3.6 RSA-B-CENB-S-18-50-B 11.1 9.7 7.6 6.9 6.2 5.1 4.3 3.6 3.3 3.0 RSA-B-CENB-S-18-50-B 7.4 6.6 5.1 4.8 4.5 3.7 3.1 2.5 RSA-B-CENB-S-20-50-B 8.8 7.6 5.9 5.2 4.7 3.8 3.2 2.6 2.4 2.2 RSA-B-CENB-S-20-50-B 5.6 4.8 3.9 3.7 3.4 2.7 2.1 1.6 RSA-B-CENB-S-22-50-B 7.0 5.9 4.4 3.9 3.5 2.8 2.2 1.8 1.6 1.5 RSA-B-CENB-S-22-50-B 4.0 3.4 2.9 2.7 2.5 1.9 1.3 0.9 RSA-B-CENB-S-24-50-B 5.4 4.4 3.2 2.8 2.4 1.9 1.4 1.1 1.0 0.8 RSA-B-CENB-S-24-50-B 2.7 2.1 2.0 1.8 1.7 1.1 0.7 NR RSA-B-CENB-S-10-50-C 25.0 25.0 25.0 24.1 22.0 18.6 15.9 13.7 12.8 11.9 RSA-B-CENB-S-10-50-C 25.0 25.0 21.5 19.2 16.7 14.6 12.9 11.4 RSA-B-CENB-S-12-50-C 25.0 25.0 20.5 18.7 17.0 14.3 12.2 10.5 9.8 9.1 RSA-B-CENB-S-12-50-C 21.3 19.5 16.4 14.9 12.9 11.2 9.8 8.6 RSA-B-CENB-S-14-50-C 22.8 20.2 16.4 14.9 13.5 11.4 9.7 8.3 7.7 7.2 RSA-B-CENB-S-14-50-C 16.9 15.4 12.8 12.0 10.3 8.9 7.7 6.7 RSA-B-CENB-S-16-50-C 18.6 16.5 13.2 12.0 10.9 9.1 7.7 6.6 6.1 5.7 RSA-B-CENB-S-16-50-C RSA-B-CENB-S-18-50-C 13.4 10.8 10.6 8.5 9.6 7.6 8.7 6.9 7.3 5.7 6.1 4.8 5.2 4.0 4.8 3.7 4.5 3.4 RSA-B-CENB-S-18-50-C 12.1 9.5 10.0 7.6 9.4 7.0 8.2 6.4 7.0 5.4 6.0 4.6 5.1 3.9 RSA-B-CENB-S-20-50-C 15.2 12.4 13.4 10.5 RSA-B-CENB-S-20-50-C 8.3 7.3 6.0 5.5 5.1 4.2 3.4 2.8 RSA-B-CENB-S-22-50-C 10.0 8.6 6.7 6.0 5.4 4.4 3.6 3.0 2.8 2.5 RSA-B-CENB-S-22-50-C 6.4 5.5 4.8 4.3 3.9 3.1 2.5 1.9 RSA-B-CENB-S-24-50-C 8.1 6.9 5.2 4.6 4.1 3.3 2.7 2.2 2.0 1.8 RSA-B-CENB-S-24-50-C 4.8 4.0 3.8 3.3 2.9 2.2 1.7 1.2 RSA-B-CENB-F-10-50-B 25.0 25.0 25.0 23.7 21.5 17.9 15.1 12.8 11.8 10.9 RSA-B-CENB-F-10-50-B 21.1 19.3 16.3 13.9 11.9 10.3 8.9 7.8 RSA-B-CENB-F-12-50-B 25.0 25.0 20.2 18.2 16.4 13.5 11.2 9.4 8.6 7.9 RSA-B-CENB-F-12-50-B 16.1 14.7 12.3 10.3 8.7 7.4 6.3 5.4 RSA-B-CENB-F-14-50-B 22.5 20.0 15.9 14.3 12.8 10.4 8.5 6.9 6.3 5.7 RSA-B-CENB-F-14-50-B 12.5 11.4 9.4 7.7 6.4 5.3 4.4 3.6 RSA-B-CENB-F-16-50-B 18.4 16.2 12.7 11.3 10.1 8.0 6.4 5.0 4.5 4.0 RSA-B-CENB-F-16-50-B 9.7 8.7 7.0 5.7 4.5 3.6 2.8 2.1 RSA-B-CENB-F-18-50-B 14.9 13.1 10.1 8.8 7.8 6.0 4.6 3.4 2.9 2.5 RSA-B-CENB-F-18-50-B 7.4 6.6 5.1 3.9 3.0 2.2 1.5 0.9 RSA-B-CENB-F-20-50-B 12.0 10.4 7.8 6.8 5.9 4.3 3.1 2.1 1.6 1.3 RSA-B-CENB-F-20-50-B 5.6 4.8 3.6 2.5 1.7 1.0 NR NR RSA-B-CENB-F-22-50-B 9.7 8.3 6.0 5.1 4.3 2.9 1.8 0.9 0.5 NR RSA-B-CENB-F-22-50-B 4.0 3.4 2.2 1.3 0.6 NR NR NR RSA-B-CENB-F-24-50-B 7.7 6.5 4.5 3.6 2.9 1.7 0.7 NR NR NR RSA-B-CENB-F-24-50-B 2.7 2.1 1.1 NR NR NR NR NR Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. © 2016 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC October 18, 2017 11:11 AM NOTES Wind-speed Website disclaimer: Hubbell Lighting has no connection to the linked website and makes no representations as to its accuracy. While the information presented on this third-party website provides a useful starting point for analyzing wind conditions, Hubbell Lighting has not verified any of the information on this third party website and assumes no responsibility or liability for its accuracy. The material presented in the windspeed website should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. Hubbell Lighting Inc. does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the windspeed report provided by this website. Users of the information from this third party website assume all liability arising from such use. Use of the output of these referenced websites do not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the windspeed report. http://windspeed.atcouncil.org • Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs. • The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide and cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application • Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty • Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this general guide; Consult local and federal standards • Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Hubbell Lighting’s Pole Vibration Application Guide for environmental risk factors and design considerations. http://cdn.spauldinglighting.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf • Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings Due to our continued efforts to improve our products, product specifications are subject to change without notice. Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. © 2016 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC October 18, 2017 11:11 AM