APPLICATIONS
Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum
allowable loading of the specified pole in its installed geographic location
CONSTRUCTION
SHAFT: One-piece straight aluminum with fluted or smooth cross section; Extruded shafts of 6061-T6 aluminum in 3/16” or
1/4” thickness. Decorative base of 356 cast aluminum.
POLE CAP OR FINALS: Cap or decorative finials available for side mounted luminaires. Open top or tenons provided for
post top mounted luminaires.
HAND HOLE: Hand hole provided in cast base; Mounting provisions for grounding lug located behind cover
ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554).
Galvanized hardware with two washers and two nuts per bolt for leveling
FINISH
Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness
Powder paint finish coat available in twelve standard colors; Custom colors available; RAL number preferable.
RSA-B-CENB
SERIES POLES
ROUND STRAIGHT ALUMINUM
Cat.#
Approvals
Job Type
BASE DETAIL
SERIES
RSA-B-
CENB
Round Straight
Aluminum Pole
Beacon
1 Specify option location using logic found on page 2 (Option Orientation)
Denotes handhole location
1
2L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23
T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
MOUNTING ORIENTATION
MOUNTING
1
Single arm mount
2
Two fixtures at 180˚
2L
Two fixtures at 90˚
3T
Three fixtures
at 90˚
3Y
Three at 120˚
4
Four fixtures at 90˚
OT Open top (in-
cludes pole cap)
TN3 Tenon 3 x 3
TN4 Tenon 3 x 4
TN5 Tenon 4 x 5
TN8 Tenon 4 x 8
ARC Acorn Finial
BAL Ball Finial
CAP Cap
FINISH
DB Dark Bronze Textured
BL Black Textured
WH White Textured
PS Platinum Silver
GYS Light Gray Smooth
BZT Bronze Textured
BBT Basic Black Textured
CC Custom Color
DRILL
PATTERN
B1
Cruzer
B3 VP-L
B4 VP-S
HEIGHT
Reference
page 2
Ordering
matrix
SHAFT
Reference
page 2
Ordering
matrix
THICKNESS
Reference
page 2
Ordering matrix
OPTIONS
GFI1
20 Amp GFCI
Receptacle and
Cover
EHH1
Extra Handhole
C051
.5” Coupling
C071
.75” Coupling
C201
2” Coupling
VM2 2nd mode
vibration
damper
LAB Less Anchor
Bolts
ORDERING EXAMPLE:
ACCESSORIES- Order Separately
Catalog Number Description
VM2SXX 2nd mode vibration damper
Bolt Circle 12.5”
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC OCTOBER 18, 2017 11:11 AM
TENONS & POLE CAPS
RSA-B-CENB 16 50 A/B/C 2L DBTB3 VM2
DECORATIVE
BASE ANCHOR
BOLT
PROJECTION
LEVELING NUT
WASHER
FOUNDATION / FOOTING
(BY OTHERS)
19.5”
5
Diameter
19.5”
STYLE
SSmooth
FFluted
S/F
ORDERING INFORMATION Cont.
NOTE Factory supplied template must be used when setting anchor bolts. Hubbell Lighting will deny any claim for incorrect anchorage placement resulting from failure to use factory supplied template and anchor bolts.
For more information about pole vibration and vibration dampers, please consult http://cdn.spauldinglighting.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
Follow the logic below when ordering location specific options. For each
option, include its orientation (in degrees) and its height (in feet). Example:
Option C07 should be ordered as: RSA-CENB-F-16-50-B-TN3-DBT (.5”
coupling on the handhole/arm side of pole, 15 feet up from the pole base)
1’ spacing required between option. Consult factory for other configura-
tions.
OPTION ORIENTATION
C05 - C07 - C20 - COUPLING VM2 - VIBRATION DAMPER
2ND MODE
EHH - EXTRA
HANDHOLE
Provision for Grounding
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
1/2” - 14 NPSM Threads
3/4” - 14 NPSM Threads
2” -11.5 NPSM Threads
Factory installed, internal damper
designed to alter pole resonance to
reduce movement and material fatigue
caused by 2nd mode vibration.
VM2SXX - VIBRATION
DAMPER 2ND MODE
Field installed, internal damper
designed to alter pole resonance
to reduce movement and mate-
rial fatigue caused by 2nd mode
vibration.
VM2S08 – 8'
VM2S12 – 12'
VM2S16 – 16'
VM2S20 – 20'
VM2S24 – 24'
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
Handhole
VIBRATION DAMPER
2ND MODE
Round Steel Pole
Standard hand
hole frame
Adapter plate
Gasket
20 AMP GFCI
Wet Locations
In-use Cover
GFI – 20 AMP GFCI
RECEPTACLE & COVER
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC OCTOBER 18, 2017 11:11 AM
Catalog Number
Height Nominal
Shaft Dimensions
Wall
Thickness
Bolt Circle
(suggested) Bolt Square Base Plate Size Anchor Bolt Size Bolt Projection Pole weight
(lbs)
Feet Meters
RSA-B-CENB-S-10-50-B 10 3.0 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 85
RSA-B-CENB-S-12-50-B 12 3.7 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 92
RSA-B-CENB-S-14-50-B 14 4.3 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 98
RSA-B-CENB-S-16-50-B 16 4.9 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 105
RSA-B-CENB-S-18-50-B 18 5.5 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 112
RSA-B-CENB-S-20-50-B 20 6.1 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 118
RSA-B-CENB-S-22-50-B 22 6.7 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 125
RSA-B-CENB-S-24-50-B 24 7.3 5" Round 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 132
RSA-B-CENB-S-10-50-C 10 3.0 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 94
RSA-B-CENB-S-12-50-C 12 3.7 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 103
RSA-B-CENB-S-14-50-C 14 4.3 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 111
RSA-B-CENB-S-16-50-C 16 4.9 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 120
RSA-B-CENB-S-18-50-C 18 5.5 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 129
RSA-B-CENB-S-20-50-C 20 6.1 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 138
RSA-B-CENB-S-22-50-C 22 6.7 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 146
RSA-B-CENB-S-24-50-C 24 7.3 5" Round 0.25" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 155
RSA-B-CENB-F-10-50-B 10 3.0 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 86
RSA-B-CENB-F-12-50-B 12 3.7 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 93
RSA-B-CENB-F-14-50-B 14 4.3 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 100
RSA-B-CENB-F-16-50-B 16 4.9 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 107
RSA-B-CENB-F-18-50-B 18 5.5 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 113
RSA-B-CENB-F-20-50-B 20 6.1 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 120
RSA-B-CENB-F-22-50-B 22 6.7 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 127
RSA-B-CENB-F-24-50-B 24 7.3 5" Fluted 0.188" 12-1/2" 8.84" 17" Dia x 19-1/2" Tall 3/4 x 30 x 4 3-1/2" 134
ASCE7-05 WIND MAP FLORIDA REGION WIND MAP
180
180
170
170
160
160
150
150
140
140
140
150
140
150
130 120 115
115
120
130
HAWAII – 105 mph
PUERTO RICO – 145 mph
NOTES:
Values are based on 50 year mean recurrence interval 30
above grade.
Hawaii has an 105 mph wind velocity.
Puerto Rico has a 125 mph wind velocity.
Caution must be exercised in determining wind velocities
in special wind areas such as:
Mountainous Regions
Areas surrounding the Great Lakes or other large bodies
of water or open land.
Areas subject to extreme wind conditions, such as
hurricanes, typhoons, cyclones, and tornadoes.
Areas adjacent to airports.
Any specific area with a known or suspected abnormally
high intermittent wind condition caused by geography,
adjacent structures, or other specific local conditions
that may not be recorded in National Weather Service
records.
Allowable pole EPA for jobsite wind conditions must be
equal to or greater than fixture EPA. Responsibility lies with
the specifier for correct pole selection based on AASHTO
wind map and job location.
The Wind Map is intended only as a general guide. Always
consult local authorities to determine maximum wind
velocities, gusting and unique wind conditions for each
specific application.
CAUTION: Wind speeds and listed EPAs are for ground
mounted installations. Poles mounted on structures (such
as bridges and buildings) must consider vibration and
coefficient of height factors beyond this general guide.
Consult AASHTO standards.
Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or
Tornadoes expose poles to flying debris, wind shear, and
other unpredictable aerodynamic forces not indicated by
the wind velocity ratings.
Pole Strength Limited Warranty: Standard, unmodified Kim
lighting Poles installed as recommended, undamaged by
corrosion, or lack of maintenance, shall withstand steady
wind conditions as provided on page 2 (Allowable Pole
EPA). Installation of poles without luminaires, or attachment
of any unauthorized accessories to poles shall void this
warranty.
85
90
90
100
110
120
130
130
140
140
140
150
150
140
130
120
110
100
90
Special Wind Region
(Consult Local Authorities)
90
Wind Map
United Sta
tes and Canada
Florida Building Code 2014 EPA Load Rating - 3 second gust wind speeds
Catalog Number 115 120 130 140 150 160 170 180
RSA-B-CENB-S-10-50-B 21.0 19.3 16.3 14.7 12.7 11.1 9.8 8.6
RSA-B-CENB-S-12-50-B 16.1 14.7 12.3 11.3 9.8 8.4 7.3 6.4
RSA-B-CENB-S-14-50-B 12.5 11.4 9.4 8.9 7.6 6.5 5.6 4.8
RSA-B-CENB-S-16-50-B 9.7 8.7 7.0 6.5 5.9 5.0 4.2 3.6
RSA-B-CENB-S-18-50-B 7.4 6.6 5.1 4.8 4.5 3.7 3.1 2.5
RSA-B-CENB-S-20-50-B 5.6 4.8 3.9 3.7 3.4 2.7 2.1 1.6
RSA-B-CENB-S-22-50-B 4.0 3.4 2.9 2.7 2.5 1.9 1.3 0.9
RSA-B-CENB-S-24-50-B 2.7 2.1 2.0 1.8 1.7 1.1 0.7 NR
RSA-B-CENB-S-10-50-C 25.0 25.0 21.5 19.2 16.7 14.6 12.9 11.4
RSA-B-CENB-S-12-50-C 21.3 19.5 16.4 14.9 12.9 11.2 9.8 8.6
RSA-B-CENB-S-14-50-C 16.9 15.4 12.8 12.0 10.3 8.9 7.7 6.7
RSA-B-CENB-S-16-50-C 13.4 12.1 10.0 9.4 8.2 7.0 6.0 5.1
RSA-B-CENB-S-18-50-C 10.5 9.5 7.6 7.0 6.4 5.4 4.6 3.9
RSA-B-CENB-S-20-50-C 8.3 7.3 6.0 5.5 5.1 4.2 3.4 2.8
RSA-B-CENB-S-22-50-C 6.4 5.5 4.8 4.3 3.9 3.1 2.5 1.9
RSA-B-CENB-S-24-50-C 4.8 4.0 3.8 3.3 2.9 2.2 1.7 1.2
RSA-B-CENB-F-10-50-B 21.1 19.3 16.3 13.9 11.9 10.3 8.9 7.8
RSA-B-CENB-F-12-50-B 16.1 14.7 12.3 10.3 8.7 7.4 6.3 5.4
RSA-B-CENB-F-14-50-B 12.5 11.4 9.4 7.7 6.4 5.3 4.4 3.6
RSA-B-CENB-F-16-50-B 9.7 8.7 7.0 5.7 4.5 3.6 2.8 2.1
RSA-B-CENB-F-18-50-B 7.4 6.6 5.1 3.9 3.0 2.2 1.5 0.9
RSA-B-CENB-F-20-50-B 5.6 4.8 3.6 2.5 1.7 1.0 NR NR
RSA-B-CENB-F-22-50-B 4.0 3.4 2.2 1.3 0.6 NR NR NR
RSA-B-CENB-F-24-50-B 2.7 2.1 1.1 NR NR NR NR NR
ASCE 7-05 wind map EPA Load Rating - 3 second gust wind speeds
Catalog Number 85 90 100 105 110 120 130 140 145 150
RSA-B-CENB-S-10-50-B 25.0 25.0 20.3 18.5 16.9 14.2 12.1 10.4 9.7 9.1
RSA-B-CENB-S-12-50-B 21.7 19.3 15.6 14.2 12.9 10.8 9.2 7.9 7.3 6.8
RSA-B-CENB-S-14-50-B 17.2 15.2 12.2 11.1 10.1 8.4 7.1 6.1 5.7 5.3
RSA-B-CENB-S-16-50-B 13.9 12.2 9.7 8.8 8.0 6.6 5.6 4.7 4.4 4.1
RSA-B-CENB-S-18-50-B 11.1 9.7 7.6 6.9 6.2 5.1 4.3 3.6 3.3 3.0
RSA-B-CENB-S-20-50-B 8.8 7.6 5.9 5.2 4.7 3.8 3.2 2.6 2.4 2.2
RSA-B-CENB-S-22-50-B 7.0 5.9 4.4 3.9 3.5 2.8 2.2 1.8 1.6 1.5
RSA-B-CENB-S-24-50-B 5.4 4.4 3.2 2.8 2.4 1.9 1.4 1.1 1.0 0.8
RSA-B-CENB-S-10-50-C 25.0 25.0 25.0 24.1 22.0 18.6 15.9 13.7 12.8 11.9
RSA-B-CENB-S-12-50-C 25.0 25.0 20.5 18.7 17.0 14.3 12.2 10.5 9.8 9.1
RSA-B-CENB-S-14-50-C 22.8 20.2 16.4 14.9 13.5 11.4 9.7 8.3 7.7 7.2
RSA-B-CENB-S-16-50-C 18.6 16.5 13.2 12.0 10.9 9.1 7.7 6.6 6.1 5.7
RSA-B-CENB-S-18-50-C 15.2 13.4 10.6 9.6 8.7 7.3 6.1 5.2 4.8 4.5
RSA-B-CENB-S-20-50-C 12.4 10.8 8.5 7.6 6.9 5.7 4.8 4.0 3.7 3.4
RSA-B-CENB-S-22-50-C 10.0 8.6 6.7 6.0 5.4 4.4 3.6 3.0 2.8 2.5
RSA-B-CENB-S-24-50-C 8.1 6.9 5.2 4.6 4.1 3.3 2.7 2.2 2.0 1.8
RSA-B-CENB-F-10-50-B 25.0 25.0 25.0 23.7 21.5 17.9 15.1 12.8 11.8 10.9
RSA-B-CENB-F-12-50-B 25.0 25.0 20.2 18.2 16.4 13.5 11.2 9.4 8.6 7.9
RSA-B-CENB-F-14-50-B 22.5 20.0 15.9 14.3 12.8 10.4 8.5 6.9 6.3 5.7
RSA-B-CENB-F-16-50-B 18.4 16.2 12.7 11.3 10.1 8.0 6.4 5.0 4.5 4.0
RSA-B-CENB-F-18-50-B 14.9 13.1 10.1 8.8 7.8 6.0 4.6 3.4 2.9 2.5
RSA-B-CENB-F-20-50-B 12.0 10.4 7.8 6.8 5.9 4.3 3.1 2.1 1.6 1.3
RSA-B-CENB-F-22-50-B 9.7 8.3 6.0 5.1 4.3 2.9 1.8 0.9 0.5 NR
RSA-B-CENB-F-24-50-B 7.7 6.5 4.5 3.6 2.9 1.7 0.7 NR NR NR
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC OCTOBER 18, 2017 11:11 AM
Florida region wind map
above is based upon 3-sec-
ond gust winds and the
2014 Florida Building Code
120 110
100
90
90
100
110
120
130
130
130
130
ALASKA REGION WIND MAP
*PRINTED WITH PERMISSION FROM ASCE
Wind-speed Website disclaimer:
Hubbell Lighting has no connection to the linked website and makes no representations as to its accuracy. While the information presented on this third-party website provides a useful
starting point for analyzing wind conditions, Hubbell Lighting has not verified any of the information on this third party website and assumes no responsibility or liability for its accuracy.
The material presented in the windspeed website should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability
and applicability by engineers or other licensed professionals. Hubbell Lighting Inc. does not intend that the use of this information replace the sound judgment of such competent
professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results
of the windspeed report provided by this website. Users of the information from this third party website assume all liability arising from such use. Use of the output of these referenced
websites do not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude
location in the windspeed report. http://windspeed.atcouncil.org
NOTES
Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs.
The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide and
cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application
Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for
correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty
Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this
general guide; Consult local and federal standards
Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Hubbell Lighting’s Pole Vibration
Application Guide for environmental risk factors and design considerations. http://cdn.spauldinglighting.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA RSA-B-CENB POLES-SPEC OCTOBER 18, 2017 11:11 AM

Navigation menu