Shark Meter In Assembly Brochure V.1.07 Self Enclosed Assemblies E173702

User Manual: Pdf Self-Enclosed Shark Meter Assemblies Brochure V.1.07 E173702

Open the PDF directly: View PDF PDF.
Page Count: 4

• For Retrofit Meter Solutions
• Extends Switchgear Capability
• Pre-Wired and Configured
• Eliminates Wiring and Installation
Errors
www.electroind.com
Electro Industries/GaugeTech
The Leader in Power Monitoring and Smart Grid Solutions
For Multi-function Shark® 50, 50B, 100, 100B, or 200 Meters
NEMA 4X
Outdoor-Rated
NEMA 1
Indoor-Rated
2
Description
EIG's Shark® meter in enclosure lets you
expand your switchgear capability without
expensive and time-consuming redesign.
Simply mount and wire the enclosure next to
your switchgear and you are ready to go, with
no downtime at all!
This is a perfect solution for a retrofit when
there is no metering compartment available.
The meter comes standard with a NEMA
1 indoor enclosure or a NEMA 4X outdoor
enclosure, and is factory wired with the meter
installed. Standard equipment includes voltage
fuses, a shorting block for current transformers,
and a control power transformer if used with
277/480 Volt power systems.
The enclosure can be ordered with either the
Shark® 50 multi-function meter, the Shark®
50B meter with native BACnet MS/TP, the
Shark® 100 multi-function meter, the Shark®
100B meter with native BACnet/IP, or the
WIRING DIAGRAMS
SHARK® ASSEMBLY INFORMATION
Door GasketKey Lock Fused Voltage
Inputs
Control Power
Transformer for
277 Voltage
Configuration
Current Input
Shorting Block
Wye Wiring for 120V
Model
Wye Wiring for 277V
Model
Shark® 200 advanced meter with
datalogging and extensive I/O. It is
offered in two voltage configurations:
• 277 Volt enclosure (comes
equipped with a control power
transformer)
• 120-240 Volt enclosure
NEMA 4X Enclosure
3
SHARK®200 METER
All fields must be filled in to create a valid part number.
Option
Numbers:
Example:
-
-
Voltage
277
120 -
120-
240 Volts
277 -
277 Volts
Shark® 50B in Self-Enclosed Meter Assembly
All fields must be filled in to create a valid part number.
Option
Numbers:
Example:
-
-
V-Switch™ Pack
V2
V1
Multifunction
Meter Only
V2
V1 plus
Power and Frequency
V3
V2 plus
Energy Counters
-
-
-
-
Communication
485P
X
None
485P
RS485 and KYZ
Pulse Output
Voltage
277
120 -
120-
240 Volts
277 -
277 Volts
Shark® 50 in Self-Enclosed Meter Assembly
Model
ENCSHK50
ENCSHK50
Shark® 50
in NEMA1
Enclosure
ENC4XSHK50
Shark® 50
in NEMA 4X
Enclosure
Model
ENCSHK50B
ENCSHK50B
Shark® 50B
in NEMA1
Enclosure
ENC4XSHK50B
Shark® 50B
in NEMA 4X
Enclosure
Frequency Current Input V-Switch™ Pack
All fields must be filled in to create a valid part number.
Option
Numbers:
Example: 60
50
50 Hz
System
60
60 Hz
System
10
10
5 Amp
Secondary
2
1 Amp
Secondary
-
-
-
-V2
V1
Multifunction
Meter Only
V2
V1 plus
Power and Frequency
V3
V2 plus
DNP 3.0 and
Energy Counters
V4
V3 plus
Limits and Harmonics
-
-
-
-
-
-
Power Supply
D2
D2 Option
Universal,
(90 to 265)
VAC @50/60Hz
or (100 to 370)
VDC
-
-
Communication
485P
X
None
485P
RS485 and KYZ
Pulse Output
INP10
100BaseT
Ethernet and
KYZ
Pulse Output
Voltage
277
120 -
120-
240 Volts
277 -
277 Volts
Shark® 100 in Self-Enclosed Meter Assembly
Model
ENCSHK100
ENCSHK100
Shark® 100
in NEMA1
Enclosure
ENC4XSHK100
Shark® 100
in NEMA 4X
Enclosure
NEMA 1 Enclosure
Front Dimensions
11.06
10.27
13.50
NEMA 4X Enclosure
Front Dimensions
DIMENSIONAL DRAWINGS
ORDERING INFORMATION
11.54
13.73
4
Ordering Information
Electro Industries/GaugeTech
1800 Shames Drive • Westbury, NY 11590
1- 877-EIMETER (1-877-346-3837) • E-Mail: sales@electroind.com
Tel: 516-334-0870 • Web Site: www.electroind.com • Fax: 516-338-4741
E173702 111015 V.1.07
Frequency Current Input V-Switch™ Pack
All fields must be filled in to create a valid part number.
Option
Numbers:
Example: 60
50
50 Hz
System
60
60 Hz
System
10
10
5 Amp
Secondary
2
1 Amp
Secondary
-
-
-
-V2
V1
Multifunction
Meter Only
V2
V1 plus
2 MB
Data-Logging
Memory
V3
V2 plus
%THD
V4
V3 plus
Limits and
Control Functions
V5
V4 plus
3 MB Data-Logging
Memory and
64 Samples/Cycle
Waveform Recorder
V6
V4 plus
4 MB Data-Logging
Memory and
512 Samples/Cycle
Waveform Recorder
-
-
-
-
-
-
Power Supply
D2
D2 Option
Universal,
(90 to 265)
VAC @50/60Hz
or (100 to 370)
VDC
-
-
I/O Slot 1
x
X
None
INP100S
10/100BaseT
Ethernet
RO1S
2 Relay
Outputs/
2 Status Inputs
PO1S
4 Pulse
Outputs/
4 Status Inputs
1mAOS
4 Channel
Analog
Output 0-1
(Bidirectional)
20mAOS
4 Channel
Analog Output
4-20mA
FOSTS
Fiber Optic
Output ST
Terminated
FOVPS
Fiber Optic
Output Versatile
Link Terminated
INP300S
IEC 61850
Protocol
Ethernet
Voltage
277
120 -
120-
240 Volts
277 -
277 Volts
Shark® 200 in Self-Enclosed Meter Assembly
I/O Slot 2
-
-x
X
None
INP100S
10/100BaseT
Ethernet
RO1S
2 Relay
Outputs/
2 Status Inputs
PO1S
4 Pulse
Outputs/
4 Status Inputs
1mAOS
4 Channel
Analog
Output 0-1
(Bidirectional)
20mAOS
4 Channel
Analog Output
4-20mA
FOSTS
Fiber Optic
Output ST
Terminated
FOVPS
Fiber Optic
Output Versatile
Link Terminated
INP300S
IEC 61850
Protocol
Ethernet
Model
ENCSHK200
ENCSHK200
Shark® 200
in NEMA1
Enclosure
ENC4XSHK200
Shark® 200
in NEMA 4X
Enclosure
Frequency Current Input
All fields must be filled in to create a valid part number.
Option
Numbers:
Example: 60
50
50 Hz
System
60
60 Hz
System
10
10
5 Amp
Secondary
2
1 Amp
Secondary
-
-
-
-
-
-
-
-
Power Supply
D2
D2 Option
Universal,
(90 to 265)
VAC @50/60Hz
or (100 to 370)
VDC
Voltage
277
120 -
120-
240 Volts
277 -
277 Volts
Shark® 100B in Self-Enclosed Meter Assembly
Model
ENCSHK100B
ENCSHK100B
Shark® 100B
in NEMA1
Enclosure
ENC4XSHK100B
Shark® 100B
in NEMA 4X
Enclosure
https://electroind.com/product-
info/self-enclosed-shark-meter-
assembly/

Navigation menu