Shark Meter In Assembly Brochure V.1.07 Self Enclosed Assemblies E173702

User Manual: Pdf Self-Enclosed Shark Meter Assemblies Brochure V.1.07 E173702

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadShark Meter In Assembly Brochure V.1.07 Self-Enclosed Assemblies E173702
Open PDF In BrowserView PDF
www.electroind.com

For Multi-function Shark® 50, 50B, 100, 100B, or 200 Meters

NEMA 4X

NEMA 1

Outdoor-Rated

Indoor-Rated

• For Retrofit Meter Solutions

• Pre-Wired and Configured

• Extends Switchgear Capability

• Eliminates Wiring and Installation
Errors

Electro Industries/GaugeTech

The Leader in Power Monitoring and Smart Grid Solutions

SHARK® ASSEMBLY INFORMATION
Description

NEMA 4X Enclosure

EIG's Shark® meter in enclosure lets you
expand your switchgear capability without
expensive and time-consuming redesign.
Simply mount and wire the enclosure next to
your switchgear and you are ready to go, with
no downtime at all!
This is a perfect solution for a retrofit when
there is no metering compartment available.
The meter comes standard with a NEMA
1 indoor enclosure or a NEMA 4X outdoor
enclosure, and is factory wired with the meter
installed. Standard equipment includes voltage
fuses, a shorting block for current transformers,
and a control power transformer if used with
277/480 Volt power systems.
The enclosure can be ordered with either the
Shark® 50 multi-function meter, the Shark®
50B meter with native BACnet MS/TP, the
Shark® 100 multi-function meter, the Shark®
100B meter with native BACnet/IP, or the

Key Lock

Door Gasket

Fused Voltage
Inputs

Shark® 200 advanced meter with
datalogging and extensive I/O. It is
offered in two voltage configurations:

Control Power
Transformer for
277 Voltage
Configuration

• 277 Volt enclosure (comes
equipped with a control power
transformer)
• 120-240 Volt enclosure

WIRING DIAGRAMS

Wye Wiring for 120V
Model
2

Current Input
Shorting Block

Wye Wiring for 277V
Model

SHARK®200

METER

DIMENSIONAL DRAWINGS

11.06
10.27

11.54

13.73

13.50

NEMA 4X Enclosure
Front Dimensions

NEMA 1 Enclosure
Front Dimensions
ORDERING INFORMATION
Shark® 50 in Self-Enclosed Meter Assembly

Shark® 50B in Self-Enclosed Meter Assembly

All fields must be filled in to create a valid part number.

All fields must be filled in to create a valid part number.

Model
Option
Numbers:
Example:

ENCSHK50

V-Switch™ Pack

Voltage

-

-

277

-

V2

Model

Communication

ENCSHK50
Shark® 50
in NEMA1
Enclosure

120 120240 Volts

V1
Multifunction
Meter Only

ENC4XSHK50
Shark® 50
in NEMA 4X
Enclosure

277 277 Volts

V2
V1 plus
Power and Frequency

Option
Numbers:

485P

ENCSHK50B

Example:

V3
V2 plus
Energy Counters

-

277

ENCSHK50B
Shark® 50B
in NEMA1
Enclosure

120 120240 Volts

ENC4XSHK50B
Shark® 50B
in NEMA 4X
Enclosure

277 277 Volts

X
None
485P
RS485 and KYZ
Pulse Output

Voltage

Shark® 100 in Self-Enclosed Meter Assembly
All fields must be filled in to create a valid part number.
Model
Option
Numbers:
Example:

ENCSHK100

Frequency

Voltage

-

277

-

60

Current Input

-

10

V-Switch™ Pack

-

V2

Power Supply

-

ENCSHK100
Shark® 100
in NEMA1
Enclosure

120 120240 Volts

50
50 Hz
System

10
5 Amp
Secondary

V1
Multifunction
Meter Only

ENC4XSHK100
Shark® 100
in NEMA 4X
Enclosure

277 277 Volts

60
60 Hz
System

2
1 Amp
Secondary

V2
V1 plus
Power and Frequency
V3
V2 plus
DNP 3.0 and
Energy Counters

D2
D2 Option
Universal,
(90 to 265)
VAC @50/60Hz
or (100 to 370)
VDC

Communication

-

485P
X
None
485P
RS485 and KYZ
Pulse Output
INP10
100BaseT
Ethernet and
KYZ
Pulse Output

V4
V3 plus
Limits and Harmonics

3

Ordering Information
Shark® 100B in Self-Enclosed Meter Assembly
All fields must be filled in to create a valid part number.
Model

Voltage

-

Option
Numbers:

ENCSHK100B

Example:

Frequency

-

277

Current Input

-

60

Power Supply

-

10

ENCSHK100B
Shark® 100B
in NEMA1
Enclosure

120 120240 Volts

50
50 Hz
System

10
5 Amp
Secondary

ENC4XSHK100B
Shark® 100B
in NEMA 4X
Enclosure

277 277 Volts

60
60 Hz
System

2
1 Amp
Secondary

D2
D2 Option
Universal,
(90 to 265)
VAC @50/60Hz
or (100 to 370)
VDC

Shark® 200 in Self-Enclosed Meter Assembly
All fields must be filled in to create a valid part number.

Option
Numbers:
Example:

ENCSHK200

Frequency

Voltage

Model

-

277

-

60

Current Input

-

10

V-Switch™ Pack

-

V2

ENCSHK200
Shark® 200
in NEMA1
Enclosure

120 120240 Volts

50
50 Hz
System

10
5 Amp
Secondary

V1
Multifunction
Meter Only

ENC4XSHK200
Shark® 200
in NEMA 4X
Enclosure

277 277 Volts

60
60 Hz
System

2
1 Amp
Secondary

V2
V1 plus
2 MB
Data-Logging
Memory

Power Supply

-

V3
V2 plus
%THD
V4
V3 plus
Limits and
Control Functions
V5
V4 plus
3 MB Data-Logging
Memory and
64 Samples/Cycle
Waveform Recorder
V6
V4 plus
4 MB Data-Logging
Memory and
512 Samples/Cycle
Waveform Recorder

Electro Industries/GaugeTech

1800 Shames Drive • Westbury, NY 11590
1- 877-EIMETER (1- 877-346-3837) • E-Mail: sales@electroind.com
Tel: 516-334-0870 • Web Site: www.electroind.com • Fax: 516-338-4741

4

D2
D2 Option
Universal,
(90 to 265)
VAC @50/60Hz
or (100 to 370)
VDC

I/O Slot 1

-

x

I/O Slot 2

-

x

X
None

X
None

INP100S
10/100BaseT
Ethernet

INP100S
10/100BaseT
Ethernet

RO1S
2 Relay
Outputs/
2 Status Inputs

RO1S
2 Relay
Outputs/
2 Status Inputs

PO1S
4 Pulse
Outputs/
4 Status Inputs

PO1S
4 Pulse
Outputs/
4 Status Inputs

1mAOS
4 Channel
Analog
Output 0-1
(Bidirectional)

1mAOS
4 Channel
Analog
Output 0-1
(Bidirectional)

20mAOS
4 Channel
Analog Output
4-20mA

20mAOS
4 Channel
Analog Output
4-20mA

FOSTS
Fiber Optic
Output ST
Terminated

FOSTS
Fiber Optic
Output ST
Terminated

FOVPS
Fiber Optic
Output Versatile
Link Terminated

FOVPS
Fiber Optic
Output Versatile
Link Terminated

INP300S
IEC 61850
Protocol
Ethernet

INP300S
IEC 61850
Protocol
Ethernet

https://electroind.com/productinfo/self-enclosed-shark-meterassembly/
E173702 111015 V.1.07



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Electro Industries
Create Date                     : 2015:11:10 11:32:42-05:00
Modify Date                     : 2015:11:10 16:56:39-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2015:11:10 16:56:39-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:65f7e3f7-850a-4e0b-9372-afde172dd5a4
Original Document ID            : adobe:docid:indd:5546d5a8-555a-11e0-a36c-f7b30d6f168b
Document ID                     : xmp.id:A05EB899C887E5118B04B4848344B134
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:9F5EB899C887E5118B04B4848344B134
Derived From Document ID        : xmp.did:9F5EB899C887E5118B04B4848344B134
Derived From Original Document ID: adobe:docid:indd:5546d5a8-555a-11e0-a36c-f7b30d6f168b
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2015:11:10 11:32:42-05:00
Format                          : application/pdf
Title                           : Shark Meter in Assembly Brochure V.1.07
Creator                         : Electro Industries
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu