Shark Meter In Assembly Brochure V.1.07 Self Enclosed Assemblies E173702
User Manual: Pdf Self-Enclosed Shark Meter Assemblies Brochure V.1.07 E173702
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
www.electroind.com For Multi-function Shark® 50, 50B, 100, 100B, or 200 Meters NEMA 4X NEMA 1 Outdoor-Rated Indoor-Rated • For Retrofit Meter Solutions • Pre-Wired and Configured • Extends Switchgear Capability • Eliminates Wiring and Installation Errors Electro Industries/GaugeTech The Leader in Power Monitoring and Smart Grid Solutions SHARK® ASSEMBLY INFORMATION Description NEMA 4X Enclosure EIG's Shark® meter in enclosure lets you expand your switchgear capability without expensive and time-consuming redesign. Simply mount and wire the enclosure next to your switchgear and you are ready to go, with no downtime at all! This is a perfect solution for a retrofit when there is no metering compartment available. The meter comes standard with a NEMA 1 indoor enclosure or a NEMA 4X outdoor enclosure, and is factory wired with the meter installed. Standard equipment includes voltage fuses, a shorting block for current transformers, and a control power transformer if used with 277/480 Volt power systems. The enclosure can be ordered with either the Shark® 50 multi-function meter, the Shark® 50B meter with native BACnet MS/TP, the Shark® 100 multi-function meter, the Shark® 100B meter with native BACnet/IP, or the Key Lock Door Gasket Fused Voltage Inputs Shark® 200 advanced meter with datalogging and extensive I/O. It is offered in two voltage configurations: Control Power Transformer for 277 Voltage Configuration • 277 Volt enclosure (comes equipped with a control power transformer) • 120-240 Volt enclosure WIRING DIAGRAMS Wye Wiring for 120V Model 2 Current Input Shorting Block Wye Wiring for 277V Model SHARK®200 METER DIMENSIONAL DRAWINGS 11.06 10.27 11.54 13.73 13.50 NEMA 4X Enclosure Front Dimensions NEMA 1 Enclosure Front Dimensions ORDERING INFORMATION Shark® 50 in Self-Enclosed Meter Assembly Shark® 50B in Self-Enclosed Meter Assembly All fields must be filled in to create a valid part number. All fields must be filled in to create a valid part number. Model Option Numbers: Example: ENCSHK50 V-Switch™ Pack Voltage - - 277 - V2 Model Communication ENCSHK50 Shark® 50 in NEMA1 Enclosure 120 120240 Volts V1 Multifunction Meter Only ENC4XSHK50 Shark® 50 in NEMA 4X Enclosure 277 277 Volts V2 V1 plus Power and Frequency Option Numbers: 485P ENCSHK50B Example: V3 V2 plus Energy Counters - 277 ENCSHK50B Shark® 50B in NEMA1 Enclosure 120 120240 Volts ENC4XSHK50B Shark® 50B in NEMA 4X Enclosure 277 277 Volts X None 485P RS485 and KYZ Pulse Output Voltage Shark® 100 in Self-Enclosed Meter Assembly All fields must be filled in to create a valid part number. Model Option Numbers: Example: ENCSHK100 Frequency Voltage - 277 - 60 Current Input - 10 V-Switch™ Pack - V2 Power Supply - ENCSHK100 Shark® 100 in NEMA1 Enclosure 120 120240 Volts 50 50 Hz System 10 5 Amp Secondary V1 Multifunction Meter Only ENC4XSHK100 Shark® 100 in NEMA 4X Enclosure 277 277 Volts 60 60 Hz System 2 1 Amp Secondary V2 V1 plus Power and Frequency V3 V2 plus DNP 3.0 and Energy Counters D2 D2 Option Universal, (90 to 265) VAC @50/60Hz or (100 to 370) VDC Communication - 485P X None 485P RS485 and KYZ Pulse Output INP10 100BaseT Ethernet and KYZ Pulse Output V4 V3 plus Limits and Harmonics 3 Ordering Information Shark® 100B in Self-Enclosed Meter Assembly All fields must be filled in to create a valid part number. Model Voltage - Option Numbers: ENCSHK100B Example: Frequency - 277 Current Input - 60 Power Supply - 10 ENCSHK100B Shark® 100B in NEMA1 Enclosure 120 120240 Volts 50 50 Hz System 10 5 Amp Secondary ENC4XSHK100B Shark® 100B in NEMA 4X Enclosure 277 277 Volts 60 60 Hz System 2 1 Amp Secondary D2 D2 Option Universal, (90 to 265) VAC @50/60Hz or (100 to 370) VDC Shark® 200 in Self-Enclosed Meter Assembly All fields must be filled in to create a valid part number. Option Numbers: Example: ENCSHK200 Frequency Voltage Model - 277 - 60 Current Input - 10 V-Switch™ Pack - V2 ENCSHK200 Shark® 200 in NEMA1 Enclosure 120 120240 Volts 50 50 Hz System 10 5 Amp Secondary V1 Multifunction Meter Only ENC4XSHK200 Shark® 200 in NEMA 4X Enclosure 277 277 Volts 60 60 Hz System 2 1 Amp Secondary V2 V1 plus 2 MB Data-Logging Memory Power Supply - V3 V2 plus %THD V4 V3 plus Limits and Control Functions V5 V4 plus 3 MB Data-Logging Memory and 64 Samples/Cycle Waveform Recorder V6 V4 plus 4 MB Data-Logging Memory and 512 Samples/Cycle Waveform Recorder Electro Industries/GaugeTech 1800 Shames Drive • Westbury, NY 11590 1- 877-EIMETER (1- 877-346-3837) • E-Mail: sales@electroind.com Tel: 516-334-0870 • Web Site: www.electroind.com • Fax: 516-338-4741 4 D2 D2 Option Universal, (90 to 265) VAC @50/60Hz or (100 to 370) VDC I/O Slot 1 - x I/O Slot 2 - x X None X None INP100S 10/100BaseT Ethernet INP100S 10/100BaseT Ethernet RO1S 2 Relay Outputs/ 2 Status Inputs RO1S 2 Relay Outputs/ 2 Status Inputs PO1S 4 Pulse Outputs/ 4 Status Inputs PO1S 4 Pulse Outputs/ 4 Status Inputs 1mAOS 4 Channel Analog Output 0-1 (Bidirectional) 1mAOS 4 Channel Analog Output 0-1 (Bidirectional) 20mAOS 4 Channel Analog Output 4-20mA 20mAOS 4 Channel Analog Output 4-20mA FOSTS Fiber Optic Output ST Terminated FOSTS Fiber Optic Output ST Terminated FOVPS Fiber Optic Output Versatile Link Terminated FOVPS Fiber Optic Output Versatile Link Terminated INP300S IEC 61850 Protocol Ethernet INP300S IEC 61850 Protocol Ethernet https://electroind.com/productinfo/self-enclosed-shark-meterassembly/ E173702 111015 V.1.07
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Electro Industries Create Date : 2015:11:10 11:32:42-05:00 Modify Date : 2015:11:10 16:56:39-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2015:11:10 16:56:39-05:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:65f7e3f7-850a-4e0b-9372-afde172dd5a4 Original Document ID : adobe:docid:indd:5546d5a8-555a-11e0-a36c-f7b30d6f168b Document ID : xmp.id:A05EB899C887E5118B04B4848344B134 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9F5EB899C887E5118B04B4848344B134 Derived From Document ID : xmp.did:9F5EB899C887E5118B04B4848344B134 Derived From Original Document ID: adobe:docid:indd:5546d5a8-555a-11e0-a36c-f7b30d6f168b Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2015:11:10 11:32:42-05:00 Format : application/pdf Title : Shark Meter in Assembly Brochure V.1.07 Creator : Electro Industries Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 4EXIF Metadata provided by EXIF.tools