APPLICATIONS
• Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum
allowable loading of the specified pole in its installed geographic location
CONSTRUCTION
• SHAFT: One-piece straight steel with square cross section, flat sides and minimum 0.238” radius on all corners; Minimum
yield of 46,000 psi (ASTM-A500, Grade B); Longitudinal weld seam to appear flush with shaft side wall; Steel base plate
with axial bolt circle slots welded flush to pole shaft having minimum yield of 36,000 psi (ASTM A36)
• BASE COVER: Two-piece square aluminum base cover included standard
• POLE CAP: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available
• HAND HOLE: Rectangular 3x5 steel hand hole frame (2.38” x 4.38” opening); Mounting provisions for grounding lug
located behind gasketed cover
• ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554).
Galvanized hardware with two washers and two nuts per bolt for leveling
FINISH
• Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness
• Powder paint prime applied over “white metal” steel substrate cleaned via mechanical shot blast method
• Decorative finish coat available in seven standard colors; Custom colors available; RAL number preferable;
Internal protective coating available
SSS-H SERIES
POLES
SQUARE STRAIGHT STEEL
Overall
Height 10' - 40'
Handhole
18"
Straight Square
and Tapered Poles
Round Straight and Tapered Poles
Anchor Bolt
Location in
Relation
to Shaft
Rotation
Anchor Bolt
Location in
Relation
to Shaft
Rotation
Engineering of
footing by others
Bolt Projection
Level Foundation
Grout with drain
Optional
Hex Nut
Flat Washer
Base Plate
Flat Washer
Hex Nut
Anchor Bolt
Handhole Handhole
(All excluding RTA Group 1
& RTS Group 2)
(RTA Group 1 &
RTS Group 2)
Cat.#
Approvals
Job Type
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING, All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com • Printed in USA SSS-H POLES-SPEC 6/17
ORDERING INFORMATION
BASE DETAIL
POLE CAP TENON BASE COVER
SERIES
SSS-H
Square Straight
Steel Pole
Hubbell Outdoor
SSS H 25 40 A/B/C 2L DBS2 UL
1 Removable tenon used in conjunction with side arm mounting. First specify desired arm
configuration followed by the “TR” notation. Example: SSS-H-25-40-A-1-S2-TR-DB
2 Specify option location using logic found on page 2 (Option Orientation)
3 VM1 recommended on poles 20’ and taller with EPA of less than 1.
Denotes handhole location
1
2L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23
T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
MOUNTING ORIENTATION
MOUNTING
1
Single arm mount
2
Two fixtures at 180˚
2L
Two fixtures at 90˚
3T
Three fixtures at 90˚
4
Four fixtures at 90˚
TA
Tenon (2.38” OD
x 4” Tall)
TB Tenon (2.88” OD
x 4” Tall)
TC Tenon (3.5” OD
x 6” Tall)
TR1Removable Tenon
(2.375 x 4.25)
OT Open Top (includes
pole cap)
FINISH
DB
Dark Bronze
Textured
BL
Black Textured
WH
White Textured
GR
Gray Textured
PS
Platinum Silver
Smooth
CC Custom Color
DRILL PATTERN
S2
#2
2 bolt 3.5”
pattern
HEIGHT
Reference page 2
Ordering matrix
SHAFT
Reference page 2
Ordering matrix
THICKNESS
Reference
page 2
Ordering matrix
OPTIONS
HSC
Internal Coating
(Hubbell Seal)
GFI2
20 Amp GFCI
Receptacle and
Cover
EHH2
Extra Handhole
C052
.5” Coupling
C072
.75” Coupling
C202
2” Coupling
MPB2
Mid-pole Luminaire
Bracket
VM2 2nd mode vibra-
tion damper
LAB Less Anchor Bolts
UL UL Certified
ORDERING EXAMPLE:
Reference page 2 for available configurations
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚
Handhole
VIBRATION DAMPER
2ND MODE
ACCESSORIES- Order Separately
Catalog Number Description
VM13 1st mode vibration damper
VM2SXX 2nd mode vibration damper
POLE TOP
.875
Ø .875
HOLE
3.875
3.5
Ø .563
3 HOLES
#2 DRILL PATTERN
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚
Handhole
VIBRATION DAMPER
2ND MODE
ORDERING INFORMATION Cont.
NOTE Factory supplied template must be used when setting anchor bolts. Hubbell Lighting will deny any claim for incorrect anchorage placement resulting from failure to use factory supplied template and anchor bolts.
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING, All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com • Printed in USA SSS-H POLES-SPEC 6/17
For more information about pole vibration and vibration dampers, please consult http://cdn.hubbelloutdoor.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
Follow the logic below when ordering location specific
options. For each option, include its orientation (in degrees)
and its height (in feet). Example: Option C07 should be
ordered as: SSS-H-20-40-A-TA-DB-CO7-0-15
(.5” coupling on the handhole/arm side of pole, 15 feet up
from the pole base) 1’ spacing required between option.
Consult factory for other configurations.
OPTION ORIENTATION
GFI – 20 AMP GFCI
RECEPTACLE & COVER
EHH - EXTRA
HANDHOLE
C05 - C07 - C20 -
COUPLING
MPB - MID POLE BRACKET
VM1 - VIBRATION DAMPER
1ST MODE
VM2 - VIBRATION DAMPER
2ND MODE
VM2SXX - VIBRATION DAMPER
2ND MODE
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Provision for Grounding
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
1/2” - 14 NPSM Threads
3/4” - 14 NPSM Threads
2” -11.5 NPSM Threads
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Square Steel Pole
Attachment stub 5” long
welded to pole
Arm, 3” Sq. x 13.5” long
ships separately
2” pipe tenon
4.25” tall
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Square Steel Pole
Standard hand
hole frame
Adapter plate
Gasket
20 AMP GFCI
Wet Locations
In-use Cover
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1
90°
Arm 2
180°
As viewed
from top
of pole.
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚
Handhole
VIBRATION DAMPER
2ND MODE
VM1
Pole
Field Installed Pole Top damper designed
to reduce pole top deflection or sway. VM1
is recommended for pole systems 25’ and
taller with a total EPA of 1.0 or less.
Factory installed, internal damper designed
to alter pole resonance to reduce movement
and material fatigue caused by 2nd mode
vibration.
Field installed, internal damper designed to
alter pole resonance to reduce movement
and material fatigue caused by 2nd mode
vibration.
VM2S08 – 8'
VM2S12 – 12'
VM2S16 – 16'
VM2S20 – 20'
VM2S24 – 24'
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚
Handhole
VIBRATION DAMPER
2ND MODE
Catalog Number
Height Nominal
Shaft Dimensions
Wall
Thickness
Bolt Circle
(suggested)
Bolt Circle
(range)
Bolt Square
(range)
Base Plate
Square Anchor bolt size Bolt Projection Pole weight
Feet Meters
SSS-H-10-40-A-XX-XX 10 3.0 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 77
SSS-H-12-40-A-XX-XX 12 3.7 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 90
SSS-H-14-40-A-XX-XX 14 4.3 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 103
SSS-H-16-40-A-XX-XX 16 4.9 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 116
SSS-H-18-40-A-XX-XX 18 5.5 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 129
SSS-H-20-40-A-XX-XX 20 6.1 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 142
SSS-H-25-40-A-XX-XX 25 7.6 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 175
SSS-H-14-40-B-XX-XX 14 4.3 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 152
SSS-H-16-40-B-XX-XX 16 4.9 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 171
SSS-H-18-40-B-XX-XX 18 5.5 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 190
SSS-H-20-40-B-XX-XX 20 6.1 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 209
SSS-H-25-40-B-XX-XX 25 7.6 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 257
SSS-H-30-40-B-XX-XX 30 9.1 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 304
SSS-H-16-50-B-XX-XX 16 4.9 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 219
SSS-H-18-50-B-XX-XX 18 5.5 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 243
SSS-H-20-50-B-XX-XX 20 6.1 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 267
SSS-H-25-50-B-XX-XX 25 7.6 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 327
SSS-H-30-50-B-XX-XX 30 9.1 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 387
SSS-H-25-50-C-XX-XX 25 7.6 5” square .25” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 427
SSS-H-30-50-C-XX-XX 30 9.1 5” square .25” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 507
SSS-H-20-60-B-XX-XX 20 6.1 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 329
SSS-H-25-60-B-XX-XX 25 7.6 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 404
SSS-H-30-60-B-XX-XX 30 9.1 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 479
SSS-H-35-60-B-XX-XX 35 10.7 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 554
SSS-H-40-60-B-XX-XX 40 12.2 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 629
SSS-H-30-60-C-XX-XX 30 9.1 6” square .25” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 614
SSS-H-35-60-C-XX-XX 35 10.7 6” square .25” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 712
SSS-H-40-60-C-XX-XX 40 12.2 6” square .25” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 809
ASCE7-05 WIND MAP FLORIDA REGION WIND MAP
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING, All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com • Printed in USA SSS-H POLES-SPEC 6/17
180
180
170
170
160
160
150
150
140
140
140
150
140
150
130 120 115
115
120
130
• Florida region wind map above is
based upon 3-second gust winds and
the 2014 Florida Building Code
HAWAII – 105 mph
PUERTO RICO – 145 mph
NOTES:
• Values are based on 50 year mean recurrence interval 30’
above grade.
• Hawaii has an 105 mph wind velocity.
• Puerto Rico has a 125 mph wind velocity.
• Caution must be exercised in determining wind velocities
in special wind areas such as:
Mountainous Regions
Areas surrounding the Great Lakes or other large bodies
of water or open land.
Areas subject to extreme wind conditions, such as
hurricanes, typhoons, cyclones, and tornadoes.
Areas adjacent to airports.
Any specific area with a known or suspected abnormally
high intermittent wind condition caused by geography,
adjacent structures, or other specific local conditions
that may not be recorded in National Weather Service
records.
• Allowable pole EPA for jobsite wind conditions must be
equal to or greater than fixture EPA. Responsibility lies with
the specifier for correct pole selection based on AASHTO
wind map and job location.
• The Wind Map is intended only as a general guide. Always
consult local authorities to determine maximum wind
velocities, gusting and unique wind conditions for each
specific application.
• CAUTION: Wind speeds and listed EPAs are for ground
mounted installations. Poles mounted on structures (such
as bridges and buildings) must consider vibration and
coefficient of height factors beyond this general guide.
Consult AASHTO standards.
• Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or
Tornadoes expose poles to flying debris, wind shear, and
other unpredictable aerodynamic forces not indicated by
the wind velocity ratings.
• Pole Strength Limited Warranty: Standard, unmodified Kim
lighting Poles installed as recommended, undamaged by
corrosion, or lack of maintenance, shall withstand steady
wind conditions as provided on page 2 (Allowable Pole
EPA). Installation of poles without luminaires, or attachment
of any unauthorized accessories to poles shall void this
warranty.
85
90
90
100
110
120
130
130
140
140
140
150
150
140
130
120
110
100
90
Special Wind Region
(Consult Local Authorities)
90
Wind Map
United Sta
tes and Canada
Florida Building Code 2014 EPA Load Rating - 3 second gust wind speeds
(Use for Florida only)
Catalog Number 115 120 130 140 150 160 170 180
SSS-H-10-40-A 25.0 25.0 25.0 25.0 21.4 18.4 15.9 13.9
SSS-H-12-40-A 25.0 25.0 23.6 19.8 16.7 14.2 12.1 10.4
SSS-H-14-40-A 25.0 23.1 19.0 15.7 13.1 10.9 99.1 7.6
SSS-H-16-40-A 20.8 18.7 15.2 12.3 10.1 8.2 6.7 5.4
SSS-H-18-40-A 16.8 15.0 11.9 9.4 7.5 5.9 4.5 3.4
SSS-H-20-40-A 13.6 11.9 9.2 7.1 5.3 3.9 2.7 1.7
SSS-H-25-40-A 7.4 6.2 4.1 2.5 1.1 NR NR NR
SSS-H-14-40-B 25.0 23.6 19.4 16.1 13.4 11.2 9.4 7.8
SSS-H-16-40-B 21.4 19.2 15.6 12.7 10.4 8.5 6.9 5.6
SSS-H-18-40-B 17.2 15.4 12.2 9.7 7.7 6.1 4.7 3.6
SSS-H-20-40-B 13.9 12.3 9.5 7.3 5.5 4.1 2.9 1.9
SSS-H-25-40-B 7.7 6.4 4.3 2.6 1.3 NR NR NR
SSS-H-30-40-B 3.2 2.1 NR NR NR NR NR NR
SSS-H-16-50-B 25.0 25.0 25.0 25.0 25.0 21.4 18.2 15.5
SSS-H-18-50-B 25.0 25.0 25.0 24.4 20.4 17.0 14.2 11.9
SSS-H-20-50-B 25.0 25.0 24.4 19.9 1 6.3 13.4 11.0 8.9
SSS-H-25-50-B 21.8 19.3 15.0 11.5 8.8 6.5 4.7 3.1
SSS-H-30-50-B 13.7 11.7 8.2 5.5 3.3 1.5 NR NR
SSS-H-25-50-C 21.8 19.3 15.0 11.5 8.8 6.5 4.7 3.1
SSS-H-30-50-C 13.7 11.7 8.2 5.5 3.3 1.5 NR NR
SSS-H-20-60-B 25.0 25.0 25.0 21.9 17.8 14.5 11.7 9.4
SSS-H-25-60-B 23.8 20.9 16.1 12.3 9.2 6.6 4.5 2.8
SSS-H-30-60-B 14.6 12.3 8.4 5.3 2.8 0.8 NR NR
SSS-H-35-60-B 7.5 5.6 2.4 NR NR NR NR NR
SSS-H-40-60-B 1.8 NR NR NR NR NR NR NR
SSS-H-30-60-C 14.6 12.3 8.4 5.3 2.8 0.8 NR NR
SSS-H-35-60-C 7.5 5.6 2.4 NR NR NR NR NR
SSS-H-40-60-C 1.8 NR NR NR NR NR NR NR
ASCE 7-05 wind map EPA Load Rating - 3 second gust wind speeds
(Use for all locations except Florida)
Catalog Number 85 90 100 105 110 120 130 140 145 150
SSS-H-10-40-A 25.0 25.0 25.0 22.8 20.6 17.0 14.2 11.9 11.0 10.1
SSS-H-12-40-A 25.0 25.0 20.0 18.0 16.1 13.2 10.8 8.9 8.1 7.4
SSS-H-14-40-A 23.1 20.4 16.1 14.3 12.8 10.2 8.2 6.6 5.9 5.3
SSS-H-16-40-A 19.0 16.7 13.0 11.5 10.1 7.9 6.2 4.7 4.1 3.6
SSS-H-18-40-A 15.6 13.6 10.0 9.0 7.8 5.9 4.4 3.1 2.6 2.1
SSS-H-20-40-A 12.7 10.9 7.9 6.9 5.9 4.2 2.8 1.7 1.3 0.9
SSS-H-25-40-A 7.3 5.9 3.8 2.9 2.1 0.8 NR NR NR NR
SSS-H-14-40-B 25.0 25.0 23.3 20.8 18.6 15.1 12.3 10.2 9.2 8.4
SSS-H-16-40-B 25.0 24.9 19.4 17.3 15.4 12.3 9.9 8.0 7.2 6.4
SSS-H-18-40-B 24.0 20.8 16.1 14.2 12.5 9.8 7.7 6.1 5.3 4.7
SSS-H-20-40-B 20.2 17.5 13.2 11.6 10.1 7.7 5.9 4.4 3.8 3.2
SSS-H-25-40-B 12.8 11.0 7.9 6.7 5.5 3.7 2.3 1.2 0.7 NR
SSS-H-30-40-B 8.0 6.6 4.1 3.1 2.2 0.8 NR NR NR NR
SSS-H-16-50-B 25.0 25.0 25.0 25.0 24.8 20.1 16.5 13.6 12.3 11.2
SSS-H-18-50-B 25.0 25.0 25.0 22.9 20.4 16.4 13.2 10.7 9.6 8.6
SSS-H-20-50-B 25.0 25.0 21.3 18.9 16.7 13.2 10.4 8.1 7.2 6.3
SSS-H-25-50-B 20.7 17.8 13.3 11.5 9.8 7.2 5.0 3.3 2.6 1.9
SSS-H-30-50-B 13.5 11.3 7.7 6.2 4.9 2.8 1.1 NR NR NR
SSS-H-25-50-C 25.0 25.0 19.4 17.1 15.1 11.7 9.0 6.9 6.0 5.1
SSS-H-30-50-C 20.1 17.3 12.7 10.9 9.3 6.6 4.5 2.8 2.1 1.4
SSS-H-20-60-B 25.0 25.0 25.0 25.0 25.0 20.2 16.1 12.9 11.5 10.3
SSS-H-25-60-B 25.0 25.0 20.6 18.0 15.6 11.8 8.7 6.2 5.2 4.2
SSS-H-30-60-B 21.4 18.1 12.9 10.7 8.8 5.7 3.3 1.3 NR NR
SSS-H-35-60-B 14.0 11.3 6.9 5.2 3.6 1.0 NR NR NR NR
SSS-H-40-60-B 8.1 5.8 2.2 nr NR NR NR NR NR NR
SSS-H-30-60-C 24.3 20.5 14.6 12.2 10.2 6.8 4.2 2.2 1.3 0.5
SSS-H-35-60-C 16.6 13.5 8.6 6.6 4.9 2.1 NR NR NR NR
SSS-H-40-60-C 10.6 7.9 3.7 2.1 0.6 NR NR NR NR NR
120 110
100
90
90
100
110
120
130
130
130
130
ALASKA REGION WIND MAP
NOTES
• Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs.
• The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide and
cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application
• Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for
correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty
• Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this
general guide; Consult local and federal standards
• Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Hubbell Lighting’s Pole Vibration
Application Guide for environmental risk factors and design considerations. http://cdn.hubbelloutdoor.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
• Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING, All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com • Printed in USA SSS-H POLES-SPEC 6/17
Due to our continued efforts to improve our products, product specifications are subject to change without notice.