SSS H Poles Spec Sheet
2017-10-21
: Pdf Sss-H Poles Spec Sheet SSS-H_Poles_spec_sheet spec products outdoor
Open the PDF directly: View PDF 
.
Page Count: 4

APPLICATIONS
•  Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum 
allowable loading of the specified pole in its installed geographic location
CONSTRUCTION
•  SHAFT: One-piece straight steel with square cross section, flat sides and minimum 0.238” radius on all corners; Minimum 
yield of 46,000 psi (ASTM-A500, Grade B); Longitudinal weld seam to appear flush with shaft side wall; Steel base plate 
with axial bolt circle slots welded flush to pole shaft having minimum yield of 36,000 psi (ASTM A36)
•  BASE COVER: Two-piece square aluminum base cover included standard
•  POLE CAP: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available
•  HAND HOLE: Rectangular 3x5 steel hand hole frame (2.38” x 4.38” opening); Mounting provisions for grounding lug 
located behind gasketed cover
•  ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). 
Galvanized hardware with two washers and two nuts per bolt for leveling
FINISH
•  Durable thermoset polyester powder coat paint finish with nominal 3.0 mil thickness
•  Powder paint prime applied over “white metal” steel substrate cleaned via mechanical shot blast method
•  Decorative finish coat available in seven standard colors; Custom colors available; RAL number preferable;  
Internal protective coating available
SSS-H SERIES
POLES
SQUARE STRAIGHT STEEL 
Overall
Height 10' - 40'
Handhole
18"
Straight Square
 and Tapered Poles
Round Straight and Tapered Poles
Anchor Bolt
Location in 
Relation
to Shaft
Rotation
Anchor Bolt
Location in 
Relation
to Shaft
Rotation
Engineering of
footing by others
Bolt Projection
Level Foundation 
Grout with drain
Optional
Hex Nut
Flat Washer
Base Plate
Flat  Washer
Hex Nut
Anchor Bolt
Handhole Handhole
(All excluding RTA Group 1 
       & RTS Group 2)
(RTA Group 1 & 
   RTS Group 2)
Cat.#
Approvals
Job Type
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING,  All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com   •  Printed in USA  SSS-H POLES-SPEC 6/17
ORDERING INFORMATION
BASE DETAIL
POLE CAP TENON BASE COVER
SERIES
SSS-H
Square Straight 
Steel Pole 
Hubbell Outdoor
SSS   H 25 40 A/B/C   2L DBS2 UL
1  Removable tenon used in conjunction with side arm mounting. First specify desired arm  
configuration followed by the “TR” notation. Example: SSS-H-25-40-A-1-S2-TR-DB
2  Specify option location using logic found on page 2 (Option Orientation)
3   VM1 recommended on poles 20’ and taller with EPA of less than 1.
Denotes handhole location
1
2L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23
T
3Y 4
Denotes handhole location
12L
23T
3Y 4
Denotes handhole location
12L
23T
3Y 4
MOUNTING ORIENTATION
MOUNTING
1
Single arm mount
2
Two fixtures at 180˚
2L
Two fixtures at 90˚
3T
Three fixtures at 90˚
4
Four fixtures at 90˚
TA
Tenon (2.38” OD      
x 4” Tall)
TB Tenon (2.88” OD     
x 4” Tall)
TC Tenon (3.5” OD     
x 6” Tall)
TR1Removable Tenon 
(2.375 x 4.25)
OT Open Top (includes 
pole cap)
FINISH
DB
Dark Bronze 
Textured
BL
Black Textured
WH
White Textured
GR
Gray Textured
PS
Platinum Silver 
Smooth
CC Custom Color
DRILL PATTERN
S2
#2  
2 bolt 3.5” 
pattern
HEIGHT
Reference page 2 
Ordering matrix
SHAFT
Reference page 2 
Ordering matrix
THICKNESS
Reference 
page 2 
Ordering matrix
OPTIONS
HSC
Internal Coating 
(Hubbell Seal)
GFI2
20 Amp GFCI 
Receptacle and 
Cover
EHH2
Extra Handhole
C052
.5” Coupling
C072
.75” Coupling
C202
2” Coupling
MPB2
Mid-pole Luminaire 
Bracket
VM2 2nd mode vibra-
tion damper
LAB Less Anchor Bolts
UL UL Certified 
ORDERING EXAMPLE: 
Reference page 2 for available configurations
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚ 
Handhole
VIBRATION DAMPER
2ND MODE
ACCESSORIES- Order Separately 
Catalog Number Description
 VM13 1st mode vibration damper
 VM2SXX  2nd mode vibration damper
POLE TOP
.875
Ø .875
HOLE
3.875
3.5
Ø .563
3 HOLES
#2 DRILL PATTERN

Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚ 
Handhole
VIBRATION DAMPER
2ND MODE
ORDERING INFORMATION Cont.
NOTE  Factory supplied template must be used when setting anchor bolts. Hubbell Lighting will deny any claim for incorrect anchorage placement resulting from failure to use factory supplied template and anchor bolts.
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING,  All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com   •  Printed in USA   SSS-H POLES-SPEC 6/17
For more information about pole vibration and vibration dampers, please consult http://cdn.hubbelloutdoor.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
Follow the logic below when ordering location specific 
options. For each option, include its orientation (in degrees) 
and its height (in feet). Example: Option C07 should be 
ordered as: SSS-H-20-40-A-TA-DB-CO7-0-15 
(.5” coupling on the handhole/arm side of pole, 15 feet up 
from the pole base) 1’ spacing required between option. 
Consult factory for other configurations.
OPTION ORIENTATION
GFI – 20 AMP GFCI
RECEPTACLE & COVER
EHH - EXTRA
HANDHOLE
C05 - C07 - C20 -
COUPLING
MPB - MID POLE BRACKET
VM1 - VIBRATION DAMPER 
         1ST MODE
VM2 - VIBRATION DAMPER  
         2ND MODE
VM2SXX - VIBRATION DAMPER  
2ND MODE
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Provision for Grounding
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
1/2” - 14 NPSM Threads
3/4” - 14 NPSM Threads
2” -11.5 NPSM Threads
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Square Steel Pole
Attachment stub 5” long
welded to pole
Arm, 3” Sq. x 13.5” long
ships separately
2” pipe tenon 
4.25” tall
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Square Steel Pole
Standard hand 
hole frame
Adapter plate
Gasket
20 AMP GFCI
Wet Locations
In-use Cover
Anchor Base Detail
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Bolt Circle
Bolt Slots/Holes
0°-Handhole
Bolt Square
270°
Arm 1 
90° 
Arm 2 
180°
As viewed 
from top 
of pole.
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚ 
Handhole
VIBRATION DAMPER
2ND MODE
VM1
Pole
Field Installed Pole Top damper designed 
to reduce pole top deflection or sway.  VM1 
is recommended for pole systems 25’ and 
taller with a total EPA of 1.0 or less.
Factory installed, internal damper designed 
to alter pole resonance to reduce movement 
and material fatigue caused by 2nd mode 
vibration.  
Field installed, internal damper designed to 
alter pole resonance to reduce movement 
and material fatigue caused by 2nd mode 
vibration.  
VM2S08 – 8'
VM2S12 – 12'
VM2S16 – 16'
VM2S20 – 20'
VM2S24 – 24'
Overall
Height 10'-30'
18"
TENON
Bolt Circle (Outer)
Bolt Circle (Inner)
Bolt Square (Outer)
Bolt Square (Inner)
Height of option in feet
BASE COVER
270˚ 90˚
180˚
0˚ 
Handhole
VIBRATION DAMPER
2ND MODE
Catalog Number 
Height Nominal 
Shaft Dimensions
Wall 
Thickness
Bolt Circle
(suggested)
Bolt Circle
(range)
Bolt Square
(range)
Base Plate 
Square Anchor bolt size Bolt Projection Pole weight
Feet Meters
SSS-H-10-40-A-XX-XX 10 3.0 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 77
SSS-H-12-40-A-XX-XX 12 3.7 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 90
SSS-H-14-40-A-XX-XX 14 4.3 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 103
SSS-H-16-40-A-XX-XX 16 4.9 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 116
SSS-H-18-40-A-XX-XX 18 5.5 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 129
SSS-H-20-40-A-XX-XX 20 6.1 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 142
SSS-H-25-40-A-XX-XX 25 7.6 4” square 0.125” 9” 8” - 10” 5.66” - 7.07” 9” 3/4” x 30” x 3” 3.5 175
SSS-H-14-40-B-XX-XX 14 4.3 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 152
SSS-H-16-40-B-XX-XX 16 4.9 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 171
SSS-H-18-40-B-XX-XX 18 5.5 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 190
SSS-H-20-40-B-XX-XX 20 6.1 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 209
SSS-H-25-40-B-XX-XX 25 7.6 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 257
SSS-H-30-40-B-XX-XX 30 9.1 4” square .188” 11” 10” - 12” 7.07” - 8.48” 10.50” 3/4” x 30” x 3” 3.5 304
SSS-H-16-50-B-XX-XX 16 4.9 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 219
SSS-H-18-50-B-XX-XX 18 5.5 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 243
SSS-H-20-50-B-XX-XX 20 6.1 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 267
SSS-H-25-50-B-XX-XX 25 7.6 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 327
SSS-H-30-50-B-XX-XX 30 9.1 5” square .188” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 387
SSS-H-25-50-C-XX-XX 25 7.6 5” square .25” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 427
SSS-H-30-50-C-XX-XX 30 9.1 5” square .25” 11” 10.25” - 13.25” 7.25” - 9.37” 11.50” 1” x 36” x 4” 4.5 507
SSS-H-20-60-B-XX-XX 20 6.1 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 329
SSS-H-25-60-B-XX-XX 25 7.6 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 404
SSS-H-30-60-B-XX-XX 30 9.1 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 479
SSS-H-35-60-B-XX-XX 35 10.7 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 554
SSS-H-40-60-B-XX-XX 40 12.2 6” square .188” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 629
SSS-H-30-60-C-XX-XX 30 9.1 6” square .25” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 614
SSS-H-35-60-C-XX-XX 35 10.7 6” square .25” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 712
SSS-H-40-60-C-XX-XX 40 12.2 6” square .25” 12” 11.00” - 13.25” 7.81” - 9.37” 12.25” 1-1/4” x 42” x 6” 5.0 809

ASCE7-05      WIND MAP                 FLORIDA REGION WIND MAP
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING,  All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com   •  Printed in USA   SSS-H POLES-SPEC 6/17
180
180
170
170
160
160
150
150
140
140
140
150
140
150
130 120 115
115
120
130
•  Florida region wind map above is 
based upon 3-second gust winds and 
the 2014 Florida Building Code
HAWAII – 105 mph 
PUERTO RICO – 145 mph
NOTES:
• Values are based on 50 year mean recurrence interval 30’ 
above grade.
• Hawaii has an 105 mph wind velocity.
• Puerto Rico has a 125 mph wind velocity.
• Caution must be exercised in determining wind velocities 
in special wind areas such as:
Mountainous Regions
Areas surrounding the Great Lakes or other large bodies 
of water or open land.
Areas subject to extreme wind conditions, such as 
hurricanes, typhoons, cyclones, and tornadoes.
Areas adjacent to airports.
Any specific area with a known or suspected abnormally 
high intermittent wind condition caused by geography, 
adjacent structures, or other specific local conditions 
that may not be recorded in National Weather Service 
records.
• Allowable pole EPA for jobsite wind conditions must be 
equal to or greater than fixture EPA. Responsibility lies with 
the specifier for correct pole selection based on AASHTO 
wind map and job location.
• The Wind Map is intended only as a general guide. Always 
consult local authorities to determine maximum wind 
velocities, gusting and unique wind conditions for each 
specific application.
• CAUTION: Wind speeds and listed EPAs are for ground 
mounted installations. Poles mounted on structures (such 
as bridges and buildings) must consider vibration and 
coefficient of height factors beyond this general guide. 
Consult AASHTO standards.
• Extreme Wind Events: Hurricanes, Typhoons, Cyclones, or 
Tornadoes expose poles to flying debris, wind shear, and 
other unpredictable aerodynamic forces not indicated by 
the wind velocity ratings. 
• Pole Strength Limited Warranty: Standard, unmodified Kim 
lighting Poles installed as recommended, undamaged by 
corrosion, or lack of maintenance, shall withstand steady 
wind conditions as provided on page 2 (Allowable Pole 
EPA). Installation of poles without luminaires, or attachment 
of any unauthorized accessories to poles shall void this 
warranty.
85
90
90
100
110
120
130
130
140
140
140     
150
150
140
130
120
110
100
90
Special Wind Region
(Consult Local Authorities)
90
Wind Map
United Sta
tes and Canada
Florida Building Code 2014 EPA Load Rating - 3 second gust wind speeds
(Use for Florida only)
Catalog Number 115 120 130 140 150 160 170 180
SSS-H-10-40-A 25.0 25.0 25.0 25.0 21.4 18.4 15.9 13.9
SSS-H-12-40-A 25.0 25.0 23.6 19.8 16.7 14.2 12.1 10.4
SSS-H-14-40-A 25.0 23.1 19.0 15.7 13.1 10.9 99.1 7.6
SSS-H-16-40-A 20.8 18.7 15.2 12.3 10.1 8.2 6.7 5.4
SSS-H-18-40-A 16.8 15.0 11.9 9.4 7.5 5.9 4.5 3.4
SSS-H-20-40-A 13.6 11.9 9.2 7.1 5.3 3.9 2.7 1.7
SSS-H-25-40-A 7.4 6.2 4.1 2.5 1.1 NR NR NR
SSS-H-14-40-B 25.0 23.6 19.4 16.1 13.4 11.2 9.4 7.8
SSS-H-16-40-B 21.4 19.2 15.6 12.7 10.4 8.5 6.9 5.6
SSS-H-18-40-B 17.2 15.4 12.2 9.7 7.7 6.1 4.7 3.6
SSS-H-20-40-B 13.9 12.3 9.5 7.3 5.5 4.1 2.9 1.9
SSS-H-25-40-B 7.7 6.4 4.3 2.6 1.3 NR NR NR
SSS-H-30-40-B 3.2 2.1 NR NR NR NR NR NR
SSS-H-16-50-B 25.0 25.0 25.0 25.0 25.0 21.4 18.2 15.5
SSS-H-18-50-B 25.0 25.0 25.0 24.4 20.4 17.0 14.2 11.9
SSS-H-20-50-B 25.0 25.0 24.4 19.9 1 6.3 13.4 11.0 8.9
SSS-H-25-50-B 21.8 19.3 15.0 11.5 8.8 6.5 4.7 3.1
SSS-H-30-50-B 13.7 11.7 8.2 5.5 3.3 1.5 NR NR
SSS-H-25-50-C 21.8 19.3 15.0 11.5 8.8 6.5 4.7 3.1
SSS-H-30-50-C 13.7 11.7 8.2 5.5 3.3 1.5 NR NR
SSS-H-20-60-B 25.0 25.0 25.0 21.9 17.8 14.5 11.7 9.4
SSS-H-25-60-B 23.8 20.9 16.1 12.3 9.2 6.6 4.5 2.8
SSS-H-30-60-B 14.6 12.3 8.4 5.3 2.8 0.8 NR NR
SSS-H-35-60-B 7.5 5.6 2.4 NR NR NR NR NR
SSS-H-40-60-B 1.8 NR NR NR NR NR NR NR
SSS-H-30-60-C 14.6 12.3 8.4 5.3 2.8 0.8 NR NR
SSS-H-35-60-C 7.5 5.6 2.4 NR NR NR NR NR
SSS-H-40-60-C 1.8 NR NR NR NR NR NR NR
ASCE 7-05 wind map EPA Load Rating - 3 second gust wind speeds
(Use for all locations except Florida)
Catalog Number 85 90 100 105 110 120 130 140 145 150
SSS-H-10-40-A 25.0 25.0 25.0 22.8 20.6 17.0 14.2 11.9 11.0 10.1
SSS-H-12-40-A 25.0 25.0 20.0 18.0 16.1 13.2 10.8 8.9 8.1 7.4
SSS-H-14-40-A 23.1 20.4 16.1 14.3 12.8 10.2 8.2 6.6 5.9 5.3
SSS-H-16-40-A 19.0 16.7 13.0 11.5 10.1 7.9 6.2 4.7 4.1 3.6
SSS-H-18-40-A 15.6 13.6 10.0 9.0 7.8 5.9 4.4 3.1 2.6 2.1
SSS-H-20-40-A 12.7 10.9 7.9 6.9 5.9 4.2 2.8 1.7 1.3 0.9
SSS-H-25-40-A 7.3 5.9 3.8 2.9 2.1 0.8 NR NR NR NR
SSS-H-14-40-B 25.0 25.0 23.3 20.8 18.6 15.1 12.3 10.2 9.2 8.4
SSS-H-16-40-B 25.0 24.9 19.4 17.3 15.4 12.3 9.9 8.0 7.2 6.4
SSS-H-18-40-B 24.0 20.8 16.1 14.2 12.5 9.8 7.7 6.1 5.3 4.7
SSS-H-20-40-B 20.2 17.5 13.2 11.6 10.1 7.7 5.9 4.4 3.8 3.2
SSS-H-25-40-B 12.8 11.0 7.9 6.7 5.5 3.7 2.3 1.2 0.7 NR
SSS-H-30-40-B 8.0 6.6 4.1 3.1 2.2 0.8 NR NR NR NR
SSS-H-16-50-B 25.0 25.0 25.0 25.0 24.8 20.1 16.5 13.6 12.3 11.2
SSS-H-18-50-B 25.0 25.0 25.0 22.9 20.4 16.4 13.2 10.7 9.6 8.6
SSS-H-20-50-B 25.0 25.0 21.3 18.9 16.7 13.2 10.4 8.1 7.2 6.3
SSS-H-25-50-B 20.7 17.8 13.3 11.5 9.8 7.2 5.0 3.3 2.6 1.9
SSS-H-30-50-B 13.5 11.3 7.7 6.2 4.9 2.8 1.1 NR NR NR
SSS-H-25-50-C 25.0 25.0 19.4 17.1 15.1 11.7 9.0 6.9 6.0 5.1
SSS-H-30-50-C 20.1 17.3 12.7 10.9 9.3 6.6 4.5 2.8 2.1 1.4
SSS-H-20-60-B 25.0 25.0 25.0 25.0 25.0 20.2 16.1 12.9 11.5 10.3
SSS-H-25-60-B 25.0 25.0 20.6 18.0 15.6 11.8 8.7 6.2 5.2 4.2
SSS-H-30-60-B 21.4 18.1 12.9 10.7 8.8 5.7 3.3 1.3 NR NR
SSS-H-35-60-B 14.0 11.3 6.9 5.2 3.6 1.0 NR NR NR NR
SSS-H-40-60-B 8.1 5.8 2.2 nr NR NR NR NR NR NR
SSS-H-30-60-C 24.3 20.5 14.6 12.2 10.2 6.8 4.2 2.2 1.3 0.5
SSS-H-35-60-C 16.6 13.5 8.6 6.6 4.9 2.1 NR NR NR NR
SSS-H-40-60-C 10.6 7.9 3.7 2.1 0.6 NR NR NR NR NR
120 110
100
90
90
100
110
120
130
130
130
130
ALASKA REGION WIND MAP

NOTES
•   Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs.
•   The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide and    
  cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application
•  Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for    
  correct pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty
•   Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond this    
  general guide; Consult local and federal standards
•   Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Hubbell Lighting’s Pole Vibration    
  Application Guide for environmental risk factors and design considerations. http://cdn.hubbelloutdoor.com/content/products/literature/literature_files/Pole_Wind_Induced_Flyer_HLOI0022.pdf
•   Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings
Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 HUBBELL OUTDOOR LIGHTING,  All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com   •  Printed in USA   SSS-H POLES-SPEC 6/17
Due to our continued efforts to improve our products, product specifications are subject to change without notice.