Str22 2 Tt
2012-02-01
: Pdf Str22-2 Tt str22-2_tt spec products columbia
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
STR22 TT 2' × 2' Stratus Recessed Indirect / 2 and 3-Lamp TT Project Information Features • Precision optical system produces an efficient luminaire without sacrificing high visual comfort • Completely recessed, provides a clean ceiling while providing soft, uniform indirect illumination in rooms with ceilings as low as 8 feet • Utilizes the popular and very efficient twin tube lamp • Light basket and reflectors are finished with a matte white powder coat • Ease of installation and maintenance • Companion Louvered (STRL), side baskets (STS) and pendant (STP) models available Project Name Type Catalog No. Date Construction Ceiling Compatibility Installation Certification Luminaire housing and end caps are die formed code gauge cold rolled steel. The aluminum reflector is profiled to a precision curve and finished with matte white paint for soft, uniform indirect illumination. Matte white perforated light basket backed by opal acrylic overlay snaps securely into place and hinges down for ease of lamp replacement. Thermoplastic light traps snap into the housing at both ends of the basket to prevent light leaks. An access plate is furnished with each luminaire for fast wiring access from the plenum. No need to open fixture. Electrical 22 Example STR22-240TTG-MPO-EPTTU – Model – No. of Lamps STR Stratus Recessed Indirect 2 Two 3 Three All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard. Ordering Information STR Luminaire is available to fit most standard ceiling types. NEC-compliant T-bar clips supplied with all grid trim fixtures. G trim fixtures used in SG ceilings require T-Bar clip accessory. See ceiling details on reverse. For hard ceilings order G trim and FK flange accessory. Assemble then support FK accessory at ceiling plane using tie wires (by others). Contact your Columbia representative for compatibility information for specific ceiling types or for continuous row applications in hard ceilings. MPO – – – Shielding Voltage G Grid Lay-in SG Slot Grid SM Surface Mount MPO Metal Perf w/Overlay U 120V-277V 347 347V Size Lamp Type Air Function Ballast 22 2' × 2' 40TT Twin Tube, 2G11 Base: 40 Watt 50TT Twin Tube, 2G11 Base: 50 Watt Blank Static A Air Handling ETT Electronic Twin Tube, Instant Start EPTT Electronic, Programmed Start Page 1/2 Rev. 04/15/10 Options Ceiling Type GLR GMF EL NYCU Fast Blow Fuse Slow Blow Fuse Emergency Battery Pack NYC Compliant, Union Made Accessories (Order Separately) FK22 2' × 2' Single Flange Kit (Shipped separately) RECESSED ARCHITECTURAL / STR22 TT © 2010 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com STR22 TT 2' × 2' Stratus Recessed Indirect / 2 and 3-Lamp TT Photometric Data Test 11862 Test Date 1/8/03 Luminaire Data Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet Zonal Lumen Summary Energy Data STR22-240TTG-MPO-EBTT Stratus Specialty Zone Lumens % Lamp % Fixt. 0-30 1101 17.5 25.7 2 × 2 2-Lamp with perforated metal and overlay C240I120RH 0.88 F40TT5 3150 65 N/A 0º= 1.25 90º= 1.35 Length: 1.92 Width: 1.88 Height: 0.00 0-40 0-60 0-90 0-180 1819 3299 4279 4279 28.9 52.4 67.9 67.9 42.5 77.1 100.0 100.0 Indoor Candela Plot RCR Coefficients of Utilization (%) 70 74 67 61 55 51 47 43 40 38 35 80 50 30 70 67 61 56 53 48 47 41 42 36 38 31 34 28 31 25 28 23 26 21 10 65 52 43 36 31 27 24 21 19 17 70 72 65 59 54 49 46 42 39 37 34 70 50 30 69 66 60 55 52 47 46 40 41 35 37 31 34 28 31 25 28 23 26 21 10 64 52 43 36 31 27 24 21 19 17 50 66 57 50 44 40 36 32 30 27 25 58 Noncompliant $4.14 based on 3000 hrs. and $0.08 per KWH AVG. LUMINANCE (Candela/Sq. M.) 700 50 30 64 54 46 39 34 31 27 25 22 20 67.9% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 90 75 RC RW 1 2 3 4 5 6 7 8 9 10 Total Luminaire Efficiency 10 62 50 42 35 31 27 23 21 19 17 0 0 56 47 39 33 28 25 22 19 17 16 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance Dimensional Data 60 Average Luminance Angle Luminaire 0 30 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90.0 4184 4008 3869 3774 3656 3515 3328 3147 2973 2742 2353 1745 4184 4060 3967 3905 3827 3722 3590 3443 3261 3030 2542 1848 4184 4180 4181 4179 4175 4185 4199 4220 4176 3768 2902 2190 4184 4290 4372 4432 4514 4622 4765 4869 4682 3791 3246 2361 4184 4328 4449 4534 4648 4799 4974 5066 4769 3929 3349 2395 1400 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 Ceiling Compatibility 2' × 2', 2-Lamp, Lay-in Recessed Type G FK22 Flange Kit Side 51/2" End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum heights of 2" allowed. 24" Surface For hard ceiling applications, fixtures must be ordered with a flange kit that wires directly into the concealed ceiling opening for a clean finished appearance. For row configurations contact your local Columbia Representative. Type SG 53/4" 25" Side For 9/16" slot grid type ceilings. Luminaire will be level with the ceiling plane. Slot grid tees must be field installed all around the fixture. Top View 31/2" A 25" End Flange kit cut out dimension for single FK22 only: 243/8" × 243/8" A C B B A A 19" 211/2" 25" Page 2/2 Rev. 04/15/10 15" K.O. Dimensions A: 5/16" Mounting K.O. B: 7/8" Supply Stem K.O. C: 2" Surface K.O. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. RECESSED ARCHITECTURAL / STR22 TT © 2010 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Modify Date : 2010:09:26 14:24:46-04:00 Create Date : 2010:09:26 14:24:46-04:00 Metadata Date : 2010:09:26 14:24:46-04:00 Document ID : uuid:250ed122-8d08-43e6-886f-4d64809cfd9b Instance ID : uuid:48d2142e-a234-4d9d-8877-b0b4f6f51b2c Format : application/pdf Page Count : 2 Signing Date : 2010:09:26 14:24:46-04:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, Export Document Usage Rights : FullSave Form Usage Rights : Add, FillIn, Delete, SubmitStandalone Signature Usage Rights : ModifyEXIF Metadata provided by EXIF.tools