STR
AIR FUNCTION
Blank Static
AAir Handling
– –
SHIELDING
MPO Metal Perf
w/Overlay
MPO – –
RECESSED ARCHITECTURAL / STR22 TT
EXAMPLE STR22240TTGMPOEPTTU
FEATURES
Precision optical system produces an ecient luminaire •
without sacricing high visual comfort
Completely recessed, provides a clean ceiling while providing •
soft, uniform indirect illumination in rooms with ceilings as
low as 8 feet
Utilizes the popular and very ecient twin tube lamp•
Light basket and reectors are nished with a matte white •
powder coat
Ease of installation and maintenance•
Companion Louvered (STRL), side baskets (STS) and pendant •
(STP) models available
SIZE
22 2' × 2'
NO. OF LAMPS
2Two
3Three
CEILING TYPE
GGrid Lay-in
SG Slot Grid
SM Surface Mount
22
ORDERING INFORMATION
LAMP TYPE
40TT Twin Tube, 2G11 Base: 40 Watt
50TT Twin Tube, 2G11 Base: 50 Watt
BALLAST
ETT Electronic Twin Tube,
Instant Start
EPTT Electronic,
Programmed Start
CONSTRUCTION
Luminaire housing and end caps are die formed
code gauge cold rolled steel. The aluminum
reector is proled to a precision curve and nished
with matte white paint for soft, uniform indirect
illumination. Matte white perforated light basket
backed by opal acrylic overlay snaps securely
into place and hinges down for ease of lamp
replacement. Thermoplastic light traps snap into
the housing at both ends of the basket to prevent
light leaks.
INSTALLATION
An access plate is furnished with each luminaire
for fast wiring access from the plenum. No need to
open xture.
ELECTRICAL
Standard class “P, thermally protected, auto-
resetting HPF ballast, sound rated A. All ballast
leads extend a minimum of 6" through access
location. NEC/CEC-compliant ballast disconnect is
standard.
CEILING COMPATIBILITY
Luminaire is available to t most standard ceiling
types. NEC-compliant T-bar clips supplied with all
grid trim xtures. G trim xtures used in SG ceilings
require T-Bar clip accessory. See ceiling details on
reverse. For hard ceilings order G trim and FK ange
accessory. Assemble then support FK accessory at
ceiling plane using tie wires (by others). Contact
your Columbia representative for compatibility
information for specic ceiling types or for
continuous row applications in hard ceilings.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
xtures labeled UL 924.
OPTIONS
GLR Fast Blow Fuse
GMF Slow Blow Fuse
EL Emergency Battery Pack
NYCU NYC Compliant, Union Made
ACCESSORIES
ORDER SEPARATELY
FK22 2' × 2' Single Flange Kit
(Shipped separately)
MODEL
STR Stratus Recessed
Indirect
VOLTAGE
U120V-277V
347 347V
Page 1/2 Rev. 04/15/10
STR22 TT
2' × 2' Stratus Recessed Indirect / 2 and 3-Lamp TT
© 2010 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
Catalog No.
Project Name Type
Date
PROJECT INFORMATION
Horiz 0-180
700
1400
0 15 30 45
90
75
60
0.0 45.0 90.0
RECESSED ARCHITECTURAL / STR22 TT
PHOTOMETRIC DATA
COEFFICIENTS OF UTILIZATION %
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
INDOOR CANDELA PLOT
Total Luminaire Eciency 67.9%
Luminaire Ecacy Rating (LER) 58
IESNA RP-1-1993 Compliance Noncompliant
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$4.14 based on
3000 hrs. and
$0.08 per KWH
LUMINAIRE DATA
AVG. LUMINANCE
Candela/Sq. M.
Test 11862 Test Date 1/8/03
0.0 22.5 45.0 67.5 90.0
Average Luminance Angle
04184 4184 4184 4184 4184
30 4008 4060 4180 4290 4328
40 3869 3967 4181 4372 4449
45 3774 3905 4179 4432 4534
50 3656 3827 4175 4514 4648
55 3515 3722 4185 4622 4799
60 3328 3590 4199 4765 4974
65 3147 3443 4220 4869 5066
70 2973 3261 4176 4682 4769
75 2742 3030 3768 3791 3929
80 2353 2542 2902 3246 3349
85 1745 1848 2190 2361 2395
Luminaire STR22-240TTG-MPO-EBTT
Stratus Specialty
2 × 2 2-Lamp with perforated
metal and overlay
Ballast C240I120RH
Ballast Factor 0.88
Lamp F40TT5
Lumens per Lamp 3150
Watts 65
Shielding Angle N/A
Spacing Criterion 0º= 1.25 90º= 1.35
Luminous Opening
in Feet
Length: 1.92
Width: 1.88
Height: 0.00
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
174 70 67 65 72 69 66 64 66 64 62 56
267 61 56 52 65 60 55 52 57 54 50 47
361 53 48 43 59 52 47 43 50 46 42 39
455 47 41 36 54 46 40 36 44 39 35 33
551 42 36 31 49 41 35 31 40 34 31 28
647 38 31 27 46 37 31 27 36 31 27 25
743 34 28 24 42 34 28 24 32 27 23 22
840 31 25 21 39 31 25 21 30 25 21 19
938 28 23 19 37 28 23 19 27 22 19 17
10 35 26 21 17 34 26 21 17 25 20 17 16
ENERGY DATAZONAL LUMEN SUMMARY
Zone Lumens % Lamp % Fixt.
0-30 1101 17. 5 25.7
0-40 1819 28.9 42.5
0-60 3299 52.4 77.1
0-90 4279 67.9 100.0
0-180 4279 67.9 100.0
A
B
A
A
CB
A
NOTE: All dimensions are in inches; dimensions and specications are subject to change without
notice. Please consult factory or check sample for verication.
Top View
K.O. Dimensions
A: ⁄" Mounting K.O.
B: ⁄" Supply Stem K.O.
C: 2" Surface K.O.
"
25"
25"
15"
19"21½"
For lay-in installation in exposed grid ceilings.
Maximum tee widths of 1" and maximum heights
of 2" allowed.
For hard ceiling applications, xtures must be
ordered with a ange kit that wires directly
into the concealed ceiling opening for a clean
nished appearance. For row congurations
contact your local Columbia Representative.
For ⁄" slot grid type ceilings. Luminaire will be level with the ceiling plane. Slot grid tees must be eld
installed all around the xture.
Flange kit cut out dimension for single FK22 only: 24⁄" × 24⁄"
Type G FK22 Flange Kit
Type SG
Side End
EndSide
DIMENSIONAL DATA CEILING COMPATIBILITY
24"
2' × 2', 2-Lamp, Lay-in
Recessed
Surface
"
25"
5¾"
Page 2/2 Rev. 04/15/10
STR22 TT
2' × 2' Stratus Recessed Indirect / 2 and 3-Lamp TT
© 2010 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com

Navigation menu