TI BLE HCI Vendor Specific Guide
TI_BLE_Vendor_Specific_HCI_Guide
TI_BLE_Vendor_Specific_HCI_Guide
TI_BLE_Vendor_Specific_HCI_Guide
TI_BLE_Vendor_Specific_HCI_Guide
TI_BLE_Vendor_Specific_HCI_Guide
User Manual: Pdf
Open the PDF directly: View PDF .
Page Count: 195
Download | |
Open PDF In Browser | View PDF |
TI BLE Vendor Specific HCI Reference Guide Version 2.1.0 TI BLE HCI Vendor Specific HCI Guide TABLE OF CONTENTS 1. PURPOSE .............................................................................................................................................. 8 2. FUNCTIONAL OVERVIEW .............................................................................................................. 8 3. NUMERICAL NOTATION CONVENTIONS .................................................................................. 9 4. DEFINITIONS, ABBREVIATIONS, ACRONYMS........................................................................ 10 5. REFERENCES .................................................................................................................................... 11 6. REVISION HISTORY ....................................................................................................................... 11 7. HCI OVERVIEW ............................................................................................................................... 12 8. SPECIFICATION INTERFACE....................................................................................................... 12 8.1 HCI INTERFACE PROTOCOL ........................................................................................................... 12 8.1.1 Command Packet .................................................................................................................. 13 8.1.2 Asynchronous Data Packet ................................................................................................... 13 8.1.3 Synchronous Data Packet ..................................................................................................... 14 8.1.4 Event Packet ......................................................................................................................... 14 8.2 HCI COMMAND ............................................................................................................................. 14 8.3 HCI EVENTS .................................................................................................................................. 16 9. VENDOR SPECIFIC INTERFACE ................................................................................................. 17 9.1 9.2 9.3 10. VENDOR SPECIFIC COMMANDS ...................................................................................................... 17 VENDOR SPECIFIC EVENTS ............................................................................................................ 22 REQUEST AND RESPONSE TUNNELING ........................................................................................... 26 HCI EXTENSION VENDOR SPECIFIC COMMANDS ............................................................ 27 10.1 10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 10.10 10.11 10.12 10.13 10.14 10.15 10.16 10.17 10.18 10.19 10.20 10.21 HCI EXTENSION SET RECEIVER GAIN ............................................................................................ 27 HCI EXTENSION SET TRANSMITTER POWER .................................................................................. 28 HCI EXTENSION ONE PACKET PER EVENT .................................................................................... 30 HCI EXTENSION CLOCK DIVIDE ON HALT ..................................................................................... 31 HCI EXTENSION DECLARE NV USAGE .......................................................................................... 32 HCI EXTENSION DECRYPT............................................................................................................. 33 HCI EXTENSION SET LOCAL SUPPORTED FEATURES ..................................................................... 34 HCI EXTENSION SET FAST TRANSMIT RESPONSE TIME ................................................................. 35 HCI EXTENSION MODEM TEST TRANSMIT .................................................................................... 36 HCI EXTENSION MODEM HOP TEST TRANSMIT ......................................................................... 37 HCI EXTENSION MODEM TEST RECEIVE ................................................................................... 38 HCI EXTENSION END MODEM TEST .......................................................................................... 39 HCI EXTENSION SET BDADDR ................................................................................................ 40 HCI EXTENSION SET SCA ......................................................................................................... 41 HCI EXTENSION ENABLE PTM .................................................................................................. 42 HCI EXTENSION SET FREQUENCY TUNING ................................................................................ 43 HCI EXTENSION SAVE FREQUENCY TUNING ............................................................................. 44 HCI EXTENSION SET MAX DTM TRANSMITTER POWER ........................................................... 45 HCI EXTENSION MAP PM IO PORT ........................................................................................... 47 HCI EXTENSION DISCONNECT IMMEDIATE ................................................................................ 49 HCI EXTENSION PACKET ERROR RATE...................................................................................... 50 Page 2 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.22 10.23 10.24 10.25 10.26 10.27 10.28 10.29 10.30 10.31 10.32 10.33 11. HCI EXTENSION VENDOR SPECIFIC EVENTS .................................................................... 65 11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.8 11.9 11.10 11.11 11.12 11.13 11.14 11.15 11.16 11.17 11.18 11.19 11.20 11.21 11.22 11.23 11.24 11.25 11.26 11.27 11.28 11.29 11.30 11.31 11.32 11.33 12. 12.1 12.2 12.3 12.4 HCI EXTENSION PACKET ERROR RATE BY CHANNEL ............................................................... 51 HCI EXTENSION EXTEND RF RANGE ......................................................................................... 53 HCI EXTENSION ADVERTISER EVENT NOTICE ........................................................................... 54 HCI EXTENSION CONNECTION EVENT NOTICE .......................................................................... 55 HCI EXTENSION HALT DURING RF ............................................................................................ 56 HCI EXTENSION SET SLAVE LATENCY OVERRIDE ..................................................................... 57 HCI EXTENSION BUILD REVISION .............................................................................................. 58 HCI EXTENSION DELAY SLEEP .................................................................................................. 59 HCI EXTENSION RESET SYSTEM ................................................................................................ 60 HCI EXTENSION OVERLAPPED PROCESSING .............................................................................. 61 HCI EXTENSION NUMBER COMPLETED PACKETS LIMIT ............................................................ 62 HCI EXTENSION GET CONNECTION INFORMATION .................................................................... 63 HCI EXTENSION SET RECEIVER GAIN ............................................................................................ 65 HCI EXTENSION SET TRANSMITTER POWER .................................................................................. 65 HCI EXTENSION ONE PACKET PER EVENT .................................................................................... 66 HCI EXTENSION CLOCK DIVIDE ON HALT ..................................................................................... 66 HCI EXTENSION DECLARE NV USAGE .......................................................................................... 67 HCI EXTENSION DECRYPT............................................................................................................. 67 HCI EXTENSION SET LOCAL SUPPORTED FEATURES ..................................................................... 68 HCI EXTENSION SET FAST TRANSMIT RESPONSE TIME ................................................................. 68 HCI EXTENSION MODEM TEST TRANSMIT .................................................................................... 69 HCI EXTENSION MODEM HOP TEST TRANSMIT ......................................................................... 69 HCI EXTENSION MODEM TEST RECEIVE ................................................................................... 70 HCI EXTENSION END MODEM TEST .......................................................................................... 70 HCI EXTENSION SET BDADDR ................................................................................................ 71 HCI EXTENSION SET SCA ......................................................................................................... 71 HCI EXTENSION ENABLE PTM .................................................................................................. 72 HCI EXTENSION SET FREQUENCY TUNING ................................................................................ 72 HCI EXTENSION SAVE FREQUENCY TUNING ............................................................................. 72 HCI EXTENSION SET MAX DTM TRANSMITTER POWER ........................................................... 73 HCI EXTENSION MAP PM IO PORT ........................................................................................... 73 HCI EXTENSION DISCONNECT IMMEDIATE ................................................................................ 74 HCI EXTENSION PACKET ERROR RATE...................................................................................... 74 HCI EXTENSION PACKET ERROR RATE BY CHANNEL ............................................................... 75 HCI EXTENSION EXTEND RF RANGE ......................................................................................... 76 HCI EXTENSION ADVERTISER EVENT NOTICE ........................................................................... 76 HCI EXTENSION CONNECTION EVENT NOTICE .......................................................................... 76 HCI EXTENSION HALT DURING RF ............................................................................................ 77 HCI EXTENSION SET SLAVE LATENCY OVERRIDE ..................................................................... 77 HCI EXTENSION BUILD REVISION .............................................................................................. 78 HCI EXTENSION DELAY SLEEP .................................................................................................. 78 HCI EXTENSION RESET SYSTEM ................................................................................................ 79 HCI EXTENSION OVERLAPPED PROCESSING .............................................................................. 80 HCI EXTENSION NUMBER COMPLETED PACKETS LIMIT ............................................................ 80 HCI EXTENSION GET CONNECTION INFORMATION .................................................................... 81 GAP VENDOR SPECIFIC COMMANDS ................................................................................... 82 GAP DEVICE INITIALIZATION......................................................................................................... 82 GAP CONFIGURE DEVICE ADDRESS .............................................................................................. 83 GAP DEVICE DISCOVERY REQUEST .............................................................................................. 84 GAP DEVICE DISCOVERY CANCEL ................................................................................................ 85 Page 3 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 12.5 GAP MAKE DISCOVERABLE .......................................................................................................... 86 12.6 GAP UPDATE ADVERTISING DATA ................................................................................................ 88 12.7 GAP END DISCOVERABLE ............................................................................................................. 89 12.8 GAP ESTABLISH LINK REQUEST .................................................................................................... 89 12.9 GAP TERMINATE LINK REQUEST................................................................................................... 91 12.10 GAP AUTHENTICATE ................................................................................................................. 92 12.11 GAP UPDATE LINK PARAMETER REQUEST ................................................................................ 95 12.12 GAP PASSKEY UPDATE ............................................................................................................. 97 12.13 GAP SLAVE SECURITY REQUEST ............................................................................................... 98 12.14 GAP SIGNABLE .......................................................................................................................... 99 12.15 GAP BOND .............................................................................................................................. 100 12.16 GAP TERMINATE AUTH ........................................................................................................... 101 12.17 GAP SET PARAMETER ............................................................................................................. 102 12.18 GAP GET PARAMETER ............................................................................................................ 106 12.19 GAP RESOLVE PRIVATE ADDRESS........................................................................................... 107 12.20 GAP SET ADVERTISEMENT TOKEN.......................................................................................... 107 12.21 GAP REMOVE ADVERTISEMENT TOKEN .................................................................................. 109 12.22 GAP UPDATE ADVERTISEMENT TOKENS ................................................................................. 111 12.22.1 GAP Bond Set Parameter ............................................................................................... 111 12.22.2 GAP Bond Get Parameter............................................................................................... 113 13. GAP VENDOR SPECIFIC EVENTS.......................................................................................... 115 13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8 13.9 13.10 13.11 13.12 13.13 13.14 13.15 13.16 13.17 14. 14.1 14.2 14.3 14.4 15. 15.1 15.2 15.3 15.4 15.5 15.6 GAP DEVICE INIT DONE .............................................................................................................. 115 GAP DEVICE DISCOVERY ............................................................................................................ 116 GAP ADVERT DATA UPDATE DONE ............................................................................................ 117 GAP MAKE DISCOVERABLE DONE .............................................................................................. 117 GAP END DISCOVERABLE DONE ................................................................................................. 118 GAP LINK ESTABLISHED ............................................................................................................. 118 GAP LINK TERMINATED .............................................................................................................. 120 GAP LINK PARMETER UPDATE .................................................................................................... 121 GAP RANDOM ADDRESS CHANGED ............................................................................................ 122 GAP SIGNATURE UPDATED ..................................................................................................... 123 GAP AUTHENTICATION COMPLETE ......................................................................................... 124 GAP PASSKEY NEEDED ........................................................................................................... 127 GAP SLAVE REQUESTED SECURITY......................................................................................... 128 GAP DEVICE INFORMATION .................................................................................................... 129 GAP BOND COMPLETE ............................................................................................................ 130 GAP PAIRING REQUESTED ....................................................................................................... 131 COMMAND STATUS .................................................................................................................. 133 UTIL VENDOR SPECIFIC COMMANDS ................................................................................ 134 UTIL NV READ COMMAND......................................................................................................... 134 UTIL NV WRITE COMMAND ....................................................................................................... 136 UTIL FORCE BOOT COMMAND.................................................................................................... 137 UTIL BUILD REVISION COMMAND .............................................................................................. 137 L2CAP VENDOR SPECIFIC COMMANDS............................................................................. 140 L2CAP_DATA (0XFCF0) ............................................................................................................ 140 L2CAP_REGISTERPSM (0XFCF1) ............................................................................................... 141 L2CAP_DEREGISTERPSM (0XFCF2) ........................................................................................... 143 L2CAP_PSMINFO (0XFCF3) ....................................................................................................... 143 L2CAP_PSMCHANNELS (0XFCF4) ............................................................................................. 145 L2CAP_CHANNELINFO (0XFCF5) .............................................................................................. 145 Page 4 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 15.7 L2CAP_CONNECTREQ (0XFC94) ............................................................................................... 148 15.8 L2CAP_CONNECTRSP (0XFC95) ................................................................................................ 148 15.9 L2CAP_DISCONNECTREQ (0XFC86) .......................................................................................... 150 15.10 L2CAP_FLOWCTRLCREDIT (0XFC96) .................................................................................... 150 15.11 L2CAP_CONNPARAMUPDATEREQ (0XFC92) ......................................................................... 151 16. L2CAP VENDOR SPECIFIC EVENTS ..................................................................................... 154 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9 17. L2CAP_CMDREJCT (0X0481) ..................................................................................................... 154 L2CAP_CONNPARAMUPDATERSP (0X0493) .............................................................................. 154 L2CAP_CONNECTREQ (0X0494) ................................................................................................ 155 L2CAP_CHANNELESTABLISHED (0X04E0) ................................................................................. 156 L2CAP_CHANNELTERMINATED (0X04E1) ................................................................................. 157 L2CAP_OUTOFCREDIT (0X04E2)............................................................................................... 158 L2CAP_PEERCREDITTHRESHOLD (0X04E3)............................................................................... 159 L2CAP_SENDSDUDONE (0X04E4) ............................................................................................. 159 L2CAP_DATA (0X04F0) ............................................................................................................. 160 ATT VENDOR SPECIFIC COMMANDS AND EVENTS ....................................................... 162 17.1 17.2 17.3 17.4 17.5 17.6 17.7 17.8 17.9 17.10 17.11 17.12 17.13 17.14 17.15 17.16 17.17 17.18 17.19 17.20 17.21 17.22 17.23 17.24 17.25 17.26 17.27 17.28 17.29 17.30 18. 18.1 18.2 18.3 ATT VENDOR SPECIFIC COMMANDS ........................................................................................... 162 ATT VENDOR SPECIFIC EVENTS .................................................................................................. 163 ATT_ERRORRSP (COMMAND = 0XFD01, EVENT = 0X0501) ...................................................... 163 ATT_EXCHANGEMTUREQ (COMMAND = 0XFD02, EVENT = 0X0502) ...................................... 164 ATT_EXCHANGEMTURSP (COMMAND = 0XFD03, EVENT = 0X0503) ....................................... 165 ATT_FINDINFOREQ (COMMAND = 0XFD04, EVENT = 0X0504) ................................................. 165 ATT_FINDINFORSP (COMMAND = 0XFD05, EVENT = 0X0505) .................................................. 165 ATT_FINDBYTYPEVALUEREQ (COMMAND = 0XFD06, EVENT = 0X0506) ................................ 166 ATT_FINDBYTYPEVALUERSP (COMMAND = 0XFD07, EVENT = 0X0507) ................................. 167 ATT_READBYTYPEREQ (COMMAND = 0XFD08, EVENT = 0X0508) ...................................... 167 ATT_READBYTYPERSP (COMMAND = 0XFD09, EVENT = 0X0509) ....................................... 168 ATT_READREQ (COMMAND = 0XFD0A, EVENT = 0X050A) .................................................. 169 ATT_READRSP (COMMAND = 0XFD0B, EVENT = 0X050B) ................................................... 169 ATT_READBLOBREQ (COMMAND = 0XFD0C, EVENT = 0X050C) ......................................... 169 ATT_READBLOBRSP (COMMAND = 0XFD0D) ....................................................................... 170 ATT_READMULTIREQ (COMMAND = 0XFD0E, EVENT = 0X050E) ........................................ 170 ATT_READMULTIRSP (COMMAND = 0XFD0F, EVENT = 0X050F) ......................................... 171 ATT_READBYGRPTYPEREQ (COMMAND = 0XFD10, EVENT = 0X0510) ............................... 171 ATT_READBYGRPTYPERSP (COMMAND = 0XFD11, EVENT = 0X0511) ................................ 172 ATT_WRITEREQ (COMMAND = 0XFD12, EVENT = 0X0512) .................................................. 172 ATT_WRITERSP (COMMAND = 0XFD13, EVENT = 0X0513) ................................................... 173 ATT_PREPAREWRITEREQ (COMMAND = 0XFD16, EVENT = 0X0516) .................................... 173 ATT_PREPAREWRITERSP (COMMAND = 0XFD17, EVENT = 0X0517) .................................... 174 ATT_EXECUTEWRITEREQ (COMMAND = 0XFD18, EVENT = 0X0518) ................................... 175 ATT_EXECUTEWRITERSP (COMMAND = 0XFD19, EVENT = 0X0519) .................................... 175 ATT_HANDLEVALUENOTI (COMMAND = 0XFD1B, EVENT = 0X051B) .................................. 175 ATT_HANDLEVALUEIND (COMMAND = 0XFD1D, EVENT = 0X051D) ................................... 176 ATT_HANDLEVALUECFM (COMMAND = 0XFD1E, EVENT = 0X051E) ................................... 176 ATT_FLOWCTRLVIOLATEDEVT (0X057E).............................................................................. 177 ATT_MTUUPDATEDEVT (0X057F) ......................................................................................... 177 GATT VENDOR SPECIFIC COMMANDS .............................................................................. 178 GATT_EXCHANGEMTU (0XFD82) ............................................................................................ 178 GATT_DISCALLPRIMARYSERVICES (0XFD90) .......................................................................... 179 GATT_DISCPRIMARYSERVICEBYUUID (0XFD86) .................................................................... 179 Page 5 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 18.4 18.5 18.6 18.7 18.8 18.9 18.10 18.11 18.12 18.13 18.14 18.15 18.16 18.17 18.18 18.19 18.20 18.21 18.22 18.23 18.24 18.25 19. 19.1 20. GATT_FINDINCLUDEDSERVICES (0XFDB0) ............................................................................... 179 GATT_DISCALLCHARS (0XFDB2) ............................................................................................. 180 GATT_DISCCHARSBYUUID (0XFD88) ..................................................................................... 181 GATT_DISCALLCHARDESCS (0XFD84) ..................................................................................... 181 GATT_READCHARVALUE (0XFD8A) ........................................................................................ 182 GATT_READUSINGCHARUUID (0XFDB4) ................................................................................ 182 GATT_READLONGCHARVALUE (0XFD8C) ........................................................................... 182 GATT_READMULTICHARVALUES (0XFD8E)......................................................................... 183 GATT_WRITENORSP (0XFDB6) ............................................................................................ 183 GATT_SIGNEDWRITENORSP (0XFDB8) ................................................................................ 184 GATT_WRITECHARVALUE (0XFD92) .................................................................................... 184 GATT_WRITELONGCHARVALUE (0XFD96) .......................................................................... 185 GATT_RELIABLEWRITES (0XFDBA) ..................................................................................... 186 GATT_READCHARDESC (0XFDBC) ...................................................................................... 186 GATT_READLONGCHARDESC (0XFDBE) ............................................................................. 187 GATT_WRITECHARDESC (0XFDC0)...................................................................................... 187 GATT_WRITELONGCHARDESC (0XFDC2) ............................................................................ 188 GATT_NOTIFICATION (0XFD9B) ............................................................................................ 188 GATT_INDICATION (0XFD9D) ............................................................................................... 189 GATT_ADDSERVICE (0XFDFC) ............................................................................................. 189 GATT_DELSERVICE (0XFDFD).............................................................................................. 190 GATT_ADDATTRIBUTE (0XFDFE) ......................................................................................... 190 GATT VENDOR SPECIFIC EVENTS ....................................................................................... 192 GATT_CLIENTCHARCFGUPDATED (0X0580) ............................................................................. 192 HOST ERROR CODES ............................................................................................................... 194 Page 6 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide TABLE OF FIGURES Figure 1: Logical Organization of Application and BLE Stack ...................................................................... 8 Figure 2: Single Device Configuration ........................................................................................................... 8 Figure 3: Dual Device Configuration .............................................................................................................. 9 Figure 4: Network Processor Configuration with HCI .................................................................................... 9 Figure 5: Command Packet ........................................................................................................................... 13 Figure 6: Asynchronous Data Packet ............................................................................................................ 13 Figure 7: Event Packet .................................................................................................................................. 14 Figure 8: Request/Response with Server Database in BLE Stack ................................................................. 26 Figure 9: Request/Response with Server Database not in BLE Stack ........................................................... 26 TABLE OF TABLES Table 1: HCI Packet Types ........................................................................................................................... 13 Table 2: BLE Commands .............................................................................................................................. 16 Table 3: BLE Events ..................................................................................................................................... 17 Table 4: Command Opcode Subgroups ........................................................................................................ 18 Table 5: Vendor Specific Commands ........................................................................................................... 21 Table 6: Event Opcode Group ...................................................................................................................... 22 Table 7: Vendor Specific Events .................................................................................................................. 25 Table 8: List of Possible Host Error Codes................................................................................................. 195 Page 7 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 1. Purpose The purpose of this document is to describe the Texas Instruments Inc. (TI) vendor specific Host Controller Interface (HCI) for Bluetooth® low energy (BLE). This document is intended for customer product software engineers and field application engineers working with the TI BLE stack software. 2. Functional Overview In BLE, there is a logical distinction between the Host software (often referred to as the higher layer stack) and the Controller software (please see Figure 1). Application BLE Profiles/Protocols BLE L2CAP BLE Host HCI LL BLE Controller PHY Figure 1: Logical Organization of Application and BLE Stack These components can either exist on the same device (single-device configuration), or be placed on separate devices (dual-device configuration) utilizing a Host Controller Interface (HCI) for communication (see section 7 for more detail). In the single-device configuration, there is obviously only one device, and the application software would execute on top of the BLE profiles and stack (please see Figure 2). Application Profile Host Controller Figure 2: Single Device Configuration Page 8 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide In the a dual-device configuration, the application software would also execute on top of the BLE profiles and stack, and only the controller would be located on a separate device (please see Figure 3). Application Profile Host HCI Controller Figure 3: Dual Device Configuration However, allowing an application to be developed on one device while communicating with the BLE stack executing on another allows access to the BLE stack that would not normally be available (please see Figure 4). PC-Based Application/ Profile HCI Host Controller Figure 4: Network Processor Configuration with HCI This configuration provides is a very convenient configuration for creating a test development environment where the “application” is actually a test tool that can execute scripts, generate logs, etc. Note however that the HCI as defined by Bluetooth only allows Controller commands and events. As such, a set of Vendor Specific commands and events will be used instead, and that is what this document intends to convey. 3. Numerical Notation Conventions Multiple-octets may be specified in hexadecimal notation in one of two ways: Standard Hexadecimal Notation In this notation, a single hexadecimal radix indicator “0x” precedes the entire value. The octet order as read from left to right is from most significant octet to least significant octet. For example, for the value 0x123456ABCDEF, ’12’ is the most significant octet and ‘EF’ is the least significant octet. Colon Separated Hexadecimal Notation In this notation, the hexadecimal radix indicator “0x” is not used and octets are colon separated. The octet order as read from left to right is from least significant octet to most significant octet. For example, for the value 12:34:56:AB:CD:EF, ’12’ is the least significant octet and ‘EF’ is the most significant octet. Page 9 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 4. Definitions, Abbreviations, Acronyms ATT Attribute Protocol BC Broadcast BLE Bluetooth Low Energy BT Bluetooth CID Channel ID CMD Command CSG Command Subgroup EC Event Code EOEF Event Opcode Event Field EOGF Event Opcode Group Field ESG Event Subgroup GAP Generic Access Profile GATT Generic Attribute Profile HCI Host Controller Interface IDE Integrated Development Environment L2CAP Logical Link Control and Adaptation Protocol LE Low Energy LL Link Layer MPS Maximum Payload Size MTU Maximum Transmission Unit OCF Opcode Command Field OGF Opcode Group Field OTA Over The Air PB Packet Boundary PER Packet Error Rate PHY Physical Layer PPM Parts Per Million PSM Protocol/Service Multiplexer SCA Sleep Clock Accuracy SDU Service Data Unit SM Security Manager NV Non-Volatile Page 10 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 5. References [1] Specification of the Bluetooth System, Core Version 4.0, June 30, 2010. http://www.bluetooth.com/Specification%20Documents/Core_V40.zip 6. Revision History Date (YMD) Document version Description of changes 2010-09-30 V1.0 Initial 2011-07-13 V1.1 BLE V1.1 RTM. 2011-12-02 V1.1b BLE V1.1b RTM. 2012-03-16 V1.2.1 BLE V1.2.1 RTM 2012-05-18 V1.2.2 BLE V1.2.2 RTM 2012-12-13 V1.3 2013-04-18 V1.3.1 BLE V1.3.1 RTM 2013-06-14 V1.3.2 BLE V1.3.2 RTM 2013-11-12 V1.4.0 BLE V1.4 RTM BLE V1.3 RTM Section 10 new HCI extended commands: HCI_EXT_SetSlaveLatencyOverrideCmd 0xFC1A HCI_EXT_BuildRevisionCmd 0xFC1B HCI_EXT_DelaySleepCmd 0xFC1C HCI_EXT_ResetSystemCmd 0xFC1D HCI_EXT_OverlappedProcessingCmd 0xFC1E HCI_Ext_NumComplPktsLimitCmd 0xFC1F Section 12.9 Changed parameter for GAP_TerminateLinkReq, added REASON parameter. Section 12.17 New parameters GAP: TGAP_CONN_PAUSE_CENTRAL/PERIPHERAL. Section 12.22.1 New GAP Bond Manager command 0x0410 ERASE_SINGLEBOND. Section 14.3 New command: UTIL_Forceboot 2015-02-27 V2.0.0 BLE V2.0 RTM Section 15 Added new commands for L2CAP Connection Oriented Channel feature Section 16 Added new events for L2CAP Connection Oriented Channel feature Marked all HCI commands as CC254x, CC264x, or both. Updated text. Added Get Number Connections command and event. Update BT Command/Event table for V4.1. Added Set Event Mask Page 2 to BLE Commands Table 2. Page 11 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Updated wording in HCI_EXT_DelaySleep command. Changed OnePacketPerEventCmd to OnePktPerEvtCmd to match code. Section 12.17 Added test modes for L2CAP Connection Oriented Channel feature Updated parameter descriptions with unit information Added warning notes for HCI_EXT_SETbdaddrCmd, HCI_EXT_PacketErrorRateCmd, and HCI_EXT_ConnEventNoticeCmd. Section 13.6 Added connection role (connRole) field to GAP_LinkEstablished event Section 14.4 Added UTIL_BuildRevision command Sections 12.10/13 & 13.13/16 Added LE Secure Connection pairing (bit 3) to ‘authReq’ field Section 13.11 Added LE Secure Connection pairing (bit 3) to ‘authState’ field Make HCI_EXT_DelaySleepCmd defunct. Updated wording in HCI Extension Reset System. 2015-04-01 V2.1.0 Updated HCI Extension Connection Event Notice for CC254x and CC264x. Renamed and updated HCI Extension Get Number of Connections to HCI Extension Get Connection Information. Section 18.23 Added minimum encryption key size ‘encKeySize’ field to GATT_AddService command. Section 17.29 Added ATT Flow Control Violated event. 7. HCI Overview The HCI is a standardized Bluetooth interface for sending commands, receiving events, and for sending and receiving data. It is typically realized as a serial interface, using either RS232 or USB communication devices. As the name implies, the HCI is used to bridge the Host and Controller devices. Commands and Events can either be specified, or can be vendor specific for extensibility. The following sections summarize the HCI protocol, the specification defined commands and events used by BLE, and a detailed description of the vendor specific commands and events defined by Texas Instruments Inc. For complete details on the HCI as specified by the Special Interest Group (SIG), please see the Core specification [1]. 8. Specification Interface 8.1 HCI Interface Protocol The HCI supports four types of packets: Command Packet, Asynchronous Data Packet, Synchronous Data Packet, and Event Packet. The packet type is a one byte value that precedes the HCI packet. The packet type has the following values: Packet Packet Type Page 12 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Command 1 Asynchronous Data 2 Synchronous Data 3 Event 4 Table 1: HCI Packet Types The contents of each packet are shown as follows (please see section 5.4 of [1], Vol. 2, Part E for additional details). 8.1.1 Command Packet The command packet is comprised of the opcode, the number of parameters, and parameters themselves. Figure 5: Command Packet 8.1.2 Asynchronous Data Packet The asynchronous data packet is comprised of the connection handle, fragmentation bits, the number of data bytes, and the data bytes themselves. Figure 6: Asynchronous Data Packet Page 13 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 8.1.3 Synchronous Data Packet This synchronous data packet is not used in BLE. 8.1.4 Event Packet The event packet is comprised of the event code, the number of event parameters, and the event parameters themselves. Figure 7: Event Packet 8.2 HCI Command HCI commands use a 16-bit opcode for identification. The opcode is subdivided into two parts: a 10-bit Opcode Command Field (OCF) and a 6-bit Opcode Group Field (OGF). HCI Command Opcode 15 10 9 0 OGF OCF The OGF values are defined by the Bluetooth (BT) Core specification. The LE specification has its own OGF value. Also, there is an escape OGF value so that vendor specific OCF codes can be used. The following OGF values are valid for BLE: Link Control Commands: 1 Link Policy Commands: 2 Controller and Baseband Commands: 3 Informational Parameters: 4 Status Parameters: 5 Testing Commands: 6 LE Only Commands: 8 Page 14 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Commands: 63 The following table lists all specification BLE commands and their opcodes. Note that while all commands can be used in a Network Processor Configuration with HCI, not all events will be returned as they will be trapped and possibly discarded by the BLE Stack. Commands LE Commands OGF OCF Opcode LE Set Event Mask 8 1 0x2001 LE Read Buffer Size 8 2 0x2002 LE Read Local Supported Features 8 3 0x2003 LE Set Random Address 8 5 0x2005 LE Set Advertising Parameters 8 6 0x2006 LE Read Advertising Channel TX Power 8 7 0x2007 LE Set Advertising Data 8 8 0x2008 LE Set Scan Response Data 8 9 0x2009 LE Set Advertise Enable 8 10 0x200A LE Set Scan Parameters 8 11 0x200B LE Set Scan Enable 8 12 0x200C LE Create Connection 8 13 0x200D LE Create Connection Cancel 8 14 0x200E LE Read White List Size 8 15 0x200F LE Clear White List 8 16 0x2010 LE Add Device To White List 8 17 0x2011 LE Remove Device From White List 8 18 0x2012 LE Connection Update 8 19 0x2013 LE Set Host Channel Classification 8 20 0x2014 LE Read Channel Map 8 21 0x2015 LE Read Remote Used Features 8 22 0x2016 LE Encrypt 8 23 0x2017 LE Rand 8 24 0x2018 LE Start Encryption 8 25 0x2019 LE Long Term Key Requested Reply 8 26 0x201A LE Long Term Key Requested Negative Reply 8 27 0x201B LE Read Supported States 8 28 0x201C Page 15 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Commands LE Commands OGF OCF Opcode LE Receiver Test 8 29 0x201D LE Transmitter Test (max TX power for CC2541 is 0 dBm) 8 30 0x201E LE Test End Command 8 31 0x201F LE Remote Connection Parameter Request Reply 8 32 0x2020 LE Remote Connection Parameter Request Negative Reply 8 33 0x2021 OGF OCF Opcode Disconnect 1 6 0x0406 Read Remote Version Information 1 29 0x041D Set Event Mask 3 1 0x0C01 Reset 3 3 0x0C03 Read Transmit Power Level 3 45 0x0C2D Set Controller To Host Flow Control (optional) 3 49 0x0C31 Host Buffer Size (optional) 3 51 0x0C33 Host Number Of Completed Packets (optional) 3 53 0x0C35 Set Event Mask Page 2 3 63 0x0C63 Read Authenticated Payload Timeout 4 123 0x0C7B Write Authenticated Payload Timeout 4 124 0x0C7C Read Local Version Information 4 1 0x1001 Read Local Supported Commands (optional) 4 2 0x1002 Read Local Supported Features 4 3 0x1003 Read BD_ADDR 4 9 0x1009 Read RSSI 5 5 0x1405 Commands BT Commands for LE Table 2: BLE Commands 8.3 HCI Events HCI events use an 8-bit event code. All event codes are unique for BT and BLE. Only event code 255 is reserved for vendor specific events. There is only one event code for all LE events. The first event parameter is used as the subevent code to distinguish the LE event types. The following table lists all the BLE events and their event codes, and subevent codes when applicable: Page 16 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Events LE Events Event Code Subevent Code LE Connection Complete 0x3E 0x01 LE Advertising Report 0x3E 0x02 LE Connection Update Complete 0x3E 0x03 LE Read Remote Used Features Complete 0x3E 0x04 LE Long Term Key Requested 0x3E 0x05 LE Remote Connection Parameter Request 0x3E 0x06 BT Events Event Code Disconnection Complete 0x05 Encryption Change 0x08 Read Remote Version Information Complete 0x0C Command Complete 0x0E Command Status 0x0F Hardware Error (optional) 0x10 Number Of Completed Packets 0x13 Data Buffer Overflow 0x1A Encryption Key Refresh Complete 0x30 Authenticated Payload Timeout Expired 0x57 Table 3: BLE Events 9. Vendor Specific Interface As mentioned, vendors can specify their own HCI commands and events by using the predefined vendor specific opcode and vendor specific event code. 9.1 Vendor Specific Commands A vendor specific opcode is indicated by an OGF value of 63. The vendor can use the remaining 10 bits (i.e. the OCF) as they like. TI defines its vendor specific OCF values by subdividing the 10 bits into a 3 MSB Command Subgroup (CSG) and a 7 LSB Command (CMD). The CSG is used by the HCI to route the commands to a designated subsystem within the BLE stack. In this way, vendor specific commands can be specified for any BLE stack layer. HCI Vendor Specific Command Opcode, CSG=0..6 15 10 9 111111b 7 6 CSG (=0..6) 0 Command The Command Subgroups are defined as follows: Page 17 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide CSG Subgroup 0 HCI 1 L2CAP 2 ATT 3 GATT 4 GAP 5 UTIL 6 Reserved 7 User Profile Table 4: Command Opcode Subgroups For Command Subgroups 0 to 6, the remaining 7 bits of Command provide up to 128 commands for each subgroup. For Subgroup 7, the remaining 7 bits specify one of 128 profiles and indicates that the subsequent byte is to be used as the command for that particular profile (i.e. up to 256 commands per profile). HCI Vendor Specific Command Opcode, CSG=7 15 10 9 111111b 7 6 0 CSG (=7) 7 Profile ID 0 Profile Command The following table lists all TI-specific HCI commands: Vendor Specific Commands LE Commands OGF CSG CMD Opcode HCI Extension Set Rx Gain 63 0 0 0xFC00 HCI Extension Set Tx Power 63 0 1 0xFC01 HCI Extension One Packet Per Event 63 0 2 0xFC02 HCI Extension Clock Divide On Halt 63 0 3 0xFC03 HCI Extension Declare NV Usage 63 0 4 0xFC04 HCI Extension Decrypt 63 0 5 0xFC05 HCI Extension Set Local Supported Features 63 0 6 0xFC06 HCI Extension Set Fast Tx Response Time 63 0 7 0xFC07 HCI Extension Modem Test Tx 63 0 8 0xFC08 Page 18 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Commands LE Commands OGF CSG CMD Opcode HCI Extension Modem Hop Test Tx 63 0 9 0xFC09 HCI Extension Modem Test Rx 63 0 10 0xFC0A HCI Extension End Modem Test 63 0 11 0xFC0B HCI Extension Set BDADDR 63 0 12 0xFC0C HCI Extension Set SCA 63 0 13 0xFC0D 63 0 14 0xFC0E HCI Extension Set Frequency Tuning 63 0 15 0xFC0F HCI Extension Save Frequency Tuning 63 0 16 0xFC10 HCI Extension Set Max DTM Tx Power 63 0 17 0xFC11 HCI Extension Map PM IO Port 63 0 18 0xFC12 HCI Extension Disconnect Immediate 63 0 19 0xFC13 63 0 20 0xFC14 HCI Extension Packet Error Rate by Channel 63 0 21 0xFC15 HCI Extension Extend RF Range 63 0 22 0xFC16 63 0 23 0xFC17 63 0 24 0xFC18 HCI Extension Halt During RF 63 0 25 0xFC19 HCI Extension Set Slave Latency Override 63 0 26 0xFC1A HCI Extension Build Revision 63 0 27 0xFC1B HCI Extension Delay Sleep 63 0 28 0xFC1C HCI Extension Reset System 63 0 29 0xFC1D HCI Extension Overlapped Processing 63 0 30 0xFC1E HCI Extension Number Completed Packets Limit 63 0 31 0xFC1F HCI Extension Get Connection Information 63 0 32 0xFC20 L2CAP Disconnection Request 63 1 6 0xFC86 L2CAP Connection Parameter Update Request 63 1 18 0xFC92 L2CAP Connection Request 63 1 20 0xFC94 L2CAP Connection Response 63 1 21 0xFC95 L2CAP Flow Control Credit 63 1 22 0xFC96 L2CAP Data 63 1 112 0xFCF0 HCI Extension Enable PTM 1 HCI Extension Packet Error Rate 2 HCI Extension Advertiser Event Notice 2 HCI Extension Connection Event Notice 2 1 Not supported by HCI; only direct function call is allowed. No event is returned. 2 Not supported by HCI; only direct function call is allowed. No event is returned. Page 19 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Commands LE Commands OGF CSG CMD Opcode L2CAP Register PSM 63 1 113 0xFCF1 L2CAP Deregister PSM 63 1 114 0xFCF2 L2CAP PSM Info 63 1 115 0xFCF3 L2CAP PSM Channels 63 1 116 0xFCF4 L2CAP Channel Info 63 1 117 0xFCF5 ATT Error Response 63 2 1 0xFD01 ATT Exchange MTU Request 63 2 2 0xFD02 ATT Exchange MTU Response 63 2 3 0xFD03 ATT Find Information Request 63 2 4 0xFD04 ATT Find Information Response 63 2 5 0xFD05 ATT Find By Type Value Request 63 2 6 0xFD06 ATT Find By Type Value Response 63 2 7 0xFD07 ATT Read By Type Request 63 2 8 0xFD08 ATT Read By Type Response 63 2 9 0xFD09 ATT Read Request 63 2 10 0xFD0A ATT Read Response 63 2 11 0xFD0B ATT Read Blob Request 63 2 12 0xFD0C ATT Read Blob Response 63 2 13 0xFD0D ATT Read Multiple Request 63 2 14 0xFD0E ATT Read Multiple Response 63 2 15 0xFD0F ATT Read By Group Type Request 63 2 16 0xFD10 ATT Read By Group Type Response 63 2 17 0xFD11 ATT Write Request 63 2 18 0xFD12 ATT Write Response 63 2 19 0xFD13 ATT Prepare Write Request 63 2 22 0xFD16 ATT Prepare Write Response 63 2 23 0xFD17 ATT Execute Write Request 63 2 24 0xFD18 ATT Execute Write Response 63 2 25 0xFD19 ATT Handle Value Notification 63 2 27 0xFD1B ATT Handle Value Indication 63 2 29 0xFD1D ATT Handle Value Confirmation 63 2 30 0xFD1E GATT Discover Characteristics By UUID 63 3 8 0xFD88 GATT Write Long 63 3 22 0xFD96 Page 20 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Commands LE Commands OGF CSG CMD Opcode GAP Device Initialization 63 4 0 0xFE00 GAP Configure Device Address 63 4 3 0xFE03 GAP Device Discovery Request 63 4 4 0xFE04 GAP Device Discovery Cancel 63 4 5 0xFE05 GAP Make Discoverable 63 4 6 0xFE06 GAP Update Advertising Data 63 4 7 0xFE07 GAP End Discoverable 63 4 8 0xFE08 GAP Establish Link Request 63 4 9 0xFE09 GAP Terminate Link Request 63 4 10 0xFE0A GAP Authenticate 63 4 11 0xFE0B GAP Passkey Update 63 4 12 0xFE0C GAP Slave Security Request 63 4 13 0xFE0D GAP Signable 63 4 14 0xFE0E GAP Bond 63 4 15 0xFE0F GAP Terminate Auth 63 4 16 0xFE10 GAP Update Link Parameter Request 63 4 17 0xFE11 GAP Set Parameter 63 4 48 0xFE30 GAP Get Parameter 63 4 49 0xFE31 GAP Resolve Private Address 63 4 50 0xFE32 GAP Set Advertisement Token 63 4 51 0xFE33 GAP Remove Advertisement Token 63 4 52 0xFE34 GAP Update Advertisement Tokens 63 4 53 0xFE35 GAP Bond Set Parameter 63 4 54 0xFE36 GAP Bond Get Parameter 63 4 55 0xFE37 UTIL Reserved 63 5 0 0xFE80 UTIL NV Read 63 5 1 0xFE81 UTIL NV Write 63 5 2 0xFE82 Reserved 63 6 0 0xFF00 User Profiles 63 7 0 0xFF80 Table 5: Vendor Specific Commands Page 21 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 9.2 Vendor Specific Events A vendor specific event code is indicated by a value of 255. The vendor must then use event parameters (following the length byte) to specify vendor specific events. TI defines the following two bytes as the Event Opcode. Event Code 7 Event Opcode 0 7 0 15 0xFF 0 Length The Event Opcode was chosen to mirror the Command Opcode by dividing it into two parts: a 6 bit Event Opcode Group Field (EOGF), and a 10 bit Event Opcode Event Field (EOEF). Event Opcode 15 10 9 0 EOGF EOEF The EOEF is again chosen to mirror the Command OCF by dividing it into two parts: the Event Subgroup (ESG) and the Event. Event Opcode 15 10 9 EOGF 7 6 ESG 0 Event The EOGF is defined as follows: EOGF Group 0 Embedded Opcode 1 Core Opcode 2 Profile Request 3 Profile Response 4 .. 63 Reserved Table 6: Event Opcode Group The ESG is defined as in Table 4. The Events are as defined in the following table. Please note that the value of the Events cannot be less than 0x400 as the first 1024 values are reserved. The reason for this has to do with Client/Server Request/Response Tunneling, which is described in the following section. Tunneling requires embedding Command Opcodes in HCI Events. When this is done, the EOGF is zero, and the remaining 10 bits is the Command Opcode. In order to prevent Command and Event Opcode overlap, the first 1024 values are reserved in the Event Opcode space. Also note that the Event Code (EC) is always 0xFF since normally only Controller events are returned via the HCI. Page 22 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Events LE Events EC EOGF ESG Event Opcode HCI Extension Set Rx Gain 0xFF 1 0 0 0x0400 HCI Extension Set Tx Power 0xFF 1 0 1 0x0401 HCI Extension One Packet Per Event 0xFF 1 0 2 0x0402 HCI Extension Clock Divide On Halt 0xFF 1 0 3 0x0403 HCI Extension Declare NV Usage 0xFF 1 0 4 0x0404 HCI Extension Decrypt 0xFF 1 0 5 0x0405 HCI Extension Set Local Supported Features 0xFF 1 0 6 0x0406 HCI Extension Set Fast Tx Response Time 0xFF 1 0 7 0x0407 HCI Extension Modem Test Tx 0xFF 1 0 8 0x0408 HCI Extension Modem Hop Test Tx 0xFF 1 0 9 0x0409 HCI Extension Modem Test Rx 0xFF 1 0 10 0x040A HCI Extension End Modem Test 0xFF 1 0 11 0x040B HCI Extension Set BDADDR 0xFF 1 0 12 0x040C HCI Extension Set SCA 0xFF 1 0 13 0x040D 0xFF 1 0 14 0x040E HCI Extension Set Frequency Tuning 0xFF 1 0 15 0x040F HCI Extension Save Frequency Tuning 0xFF 1 0 16 0x0410 HCI Extension Set Max DTM Tx Power 0xFF 1 0 17 0x0411 HCI Extension Map PM IO Port 0xFF 1 0 18 0x0412 HCI Extension Disconnect Immediate 0xFF 1 0 19 0x0413 HCI Extension Packet Error Rate 0xFF 1 0 20 0x0414 HCI Extension Packet Error Rate by Channel 0xFF 1 0 21 0x0415 HCI Extension Extend RF Range 0xFF 1 0 22 0x0416 0xFF 1 0 23 0x0417 0xFF 1 0 24 0x0418 HCI Extension Halt During RF 0xFF 1 0 25 0x0419 HCI Extension Set Slave Latency Override 0xFF 1 0 26 0x041A HCI Extension Build Revision 0xFF 1 0 27 0x041B HCI Extension Delay Sleep 0xFF 1 0 28 0x041C HCI Extension Reset System 0xFF 1 0 29 0x041D HCI Extension Enable PTM 3 3 HCI Extension Advertiser Event Notice 3 HCI Extension Connection Event Notice 3 3 Not supported by HCI; only direct function call is allowed. No event is returned. Page 23 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Events LE Events EC EOGF ESG Event Opcode HCI Extension Overlapped Processing 0xFF 1 0 30 0x041E HCI Extension Number Completed Packets Limit 0xFF 1 0 31 0x041F HCI Extension Get Connection Information 0xFF 1 0 32 0x0420 L2CAP Command Reject 0xFF 1 1 1 0x0481 L2CAP Connection Parameter Update Response 0xFF 1 1 19 0x0493 L2CAP Connection Request 0xFF 1 1 20 0x0494 L2CAP Channel Established 0xFF 1 1 96 0x04E0 L2CAP Channel Terminated 0xFF 1 1 97 0x04E1 L2CAP Out Of Credit 0xFF 1 1 98 0x04E2 L2CAP Peer Credit Threshold 0xFF 1 1 99 0x04E3 L2CAP Send SDU Done 0xFF 1 1 100 0x04E4 L2CAP Data 0xFF 1 1 112 0x04F0 ATT Error Response 0xFF 1 2 1 0x0501 ATT Exchange MTU Request 0xFF 1 2 2 0x0502 ATT Exchange MTU Response 0xFF 1 2 3 0x0503 ATT Find Information Request 0xFF 1 2 4 0x0504 ATT Find Information Request 0xFF 1 2 5 0x0505 ATT Find By Type Value Request 0xFF 1 2 6 0x0506 ATT Find By Type Value Response 0xFF 1 2 7 0x0507 ATT Read By Type Request 0xFF 1 2 8 0x0508 ATT Read By Type Response 0xFF 1 2 9 0x0509 ATT Read Request 0xFF 1 2 10 0x050A ATT Read Response 0xFF 1 2 11 0x050B ATT Read Blob Request 0xFF 1 2 12 0x050C ATT Read Blob Response 0xFF 1 2 13 0x050D ATT Read Multiple Request 0xFF 1 2 14 0x050E ATT Read Multiple Response 0xFF 1 2 15 0x050F ATT Read By Group Type Request 0xFF 1 2 16 0x0510 ATT Read By Group Type Response 0xFF 1 2 17 0x0511 ATT Write Request 0xFF 1 2 18 0x0512 ATT Write Response 0xFF 1 2 19 0x0513 ATT Prepare Write Request 0xFF 1 2 22 0x0516 ATT Prepare Write Response 0xFF 1 2 23 0x0517 Page 24 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Vendor Specific Events LE Events EC EOGF ESG Event Opcode ATT Execute Write Request 0xFF 1 2 24 0x0518 ATT Execute Write Response 0xFF 1 2 25 0x0519 ATT Handle Value Notification 0xFF 1 2 27 0x051B ATT Handle Value Indication 0xFF 1 2 29 0x051D ATT Handle Value Confirmation 0xFF 1 2 30 0x051E GAP Device Init Done 0xFF 1 4 0 0x0600 GAP Device Discovery 0xFF 1 4 1 0x0601 GAP Advert Data Update Done 0xFF 1 4 2 0x0602 GAP Make Discoverable Done 0xFF 1 4 3 0x0603 GAP End Discoverable Done 0xFF 1 4 4 0x0604 GAP Link Established 0xFF 1 4 5 0x0605 GAP Link Terminated 0xFF 1 4 6 0x0606 GAP Link Parameter Update 0xFF 1 4 7 0x0607 GAP Random Address Changed 0xFF 1 4 8 0x0608 GAP Signature Updated 0xFF 1 4 9 0x0609 GAP Authentication Complete 0xFF 1 4 10 0x060A GAP Passkey Needed 0xFF 1 4 11 0x060B GAP Slave Requested Security 0xFF 1 4 12 0x060C GAP Device Information 0xFF 1 4 13 0x060D GAP Bond Complete 0xFF 1 4 14 0x060E GAP Pairing Requested 0xFF 1 4 15 0x060F Command Status 0xFF 1 4 127 0x067F Table 7: Vendor Specific Events You will note that there are two EOGF values for Profiles. At this time, no profiles are defined well enough to document here. These values are defined in anticipation of not only needing large numbers of profiles and their commands, but also of needing the direction the command is travelling when embedded in an HCI Command or Event. You can see that ATT does not have this issue as these commands are already defined using even values for commands and odd values for events, and thus, direction is distinguishable. For profiles, it is not yet known how the commands and events will be defined. Page 25 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 9.3 Request and Response Tunneling In the Client/Server model defined and supported by the BLE stack, the Client sends Requests to the Server and the Server sends Responses back to the Client. The Requests sent by the Client may be handled by a Server on the same device, or they may travel OTA to the Server on another device. Similarly, the Response sent by the Server may be handled by a Client on the same device, or may be sent OTA to a Client on another device from which the request came. But in either case, as long as the Requests and Responses remain within the scope of the BLE stack software (i.e. the BLE Server database is on the device), the BLE stack remains unconcerned about whether the Requests and Responses are sent/received by the same device or are from another device. Please see Figure 8. HCI Command Client Request Client Request HCI HCI Event Server Response Server Response HCI BLE Device (Network Processor Configuration with HCI) OTA BLE Device (Single Device Configuration) Figure 8: Request/Response with Server Database in BLE Stack However, when using the Network Processor Configuration with HCI such that the Server database is not located on the device, then Requests and Reponses have to be mapped into HCI Commands and Events. The HCI is specified such that only Commands are sent from the Host to the Controller, and only Events are sent from the Controller to the Host. If the Server database is located on say a PC, then when an OTA Request is received by the Server device, it must be sent to the PC via the HCI. Even though the Request started out on one end as an HCI Command, it must be provided to the remote PC as an HCI event on the other. Similarly, when the PC sends the Response on one end, which will be an HCI Event to the remote PC on the other, it must be sent to the device as an HCI Command. Thus, the Request, which starts out as an HCI Command, must be embedded in an HCI Event when received by the remote PC, and the Response, which starts out as an HCI Command, must be embedded in an HCI Event when received by the remote PC. In this way, Requests and Responses are being tunneled in HCI Commands and Events. Please see Figure 9. HCI Command Client Request Client Request HCI Event HCI HCI Event Server Response Server Response HCI HCI BLE Device (Network Processor Configuration with HCI) OTA BLE Device (Network Processor Configuration with HCI) Client Request Client Request HCI Command HCI Server Response Figure 9: Request/Response with Server Database not in BLE Stack Page 26 of 195 Copyright © 2014-2015 Texas Instruments Inc. Server Response TI BLE HCI Vendor Specific HCI Guide 10. HCI Extension Vendor Specific Commands In addition to the BLE HCI commands, the following HCI Extension vendor specific commands are also available. Please note that some of these commands may not be supported on the CC264x platform. 10.1 HCI Extension Set Receiver Gain Command Opcode Command Parameters Return Parameters HCI_EXT_SetRxGainCmd 0xFC00 rxGain Status Description CC254x: CC264x: This command is used to set the RF receiver gain. The default system value for this feature is standard receiver gain. Command Parameters rxGain: (1 byte) Value Parameter Description 0x00 HCI_EXT_RX_GAIN_STD 0x01 HCI_EXT_RX_GAIN_HIGH Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetRxGainCmd has completed, a vendor specific Command Complete event shall be generated. Page 27 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.2 HCI Extension Set Transmitter Power Command Opcode Command Parameters Return Parameters HCI_EXT_SetTxPowerCmd 0xFC01 txPower Status Description CC254x: CC264x: This command is used to set the RF transmitter output power. The default system value for this feature is 0 dBm. Note that for the CC254x platform, a setting of 4dBm is only allowed for the CC2540. Command Parameters txPower: (1 byte) - CC254x Value Parameter Description 0x00 HCI_EXT_TX_POWER_MINUS_23_DBM 0x01 HCI_EXT_TX_POWER_MINUS_6_DBM 0x02 HCI_EXT_TX_POWER_0_DBM 0x03 HCI_EXT_TX_POWER_4_DBM (CC2540 only) txPower: (1 byte) - CC264x Value Parameter Description 0x00 HCI_EXT_TX_POWER_MINUS_21_DBM 0x01 HCI_EXT_TX_POWER_MINUS_18_DBM 0x02 HCI_EXT_TX_POWER_MINUS_15_DBM 0x03 HCI_EXT_TX_POWER_MINUS_12_DBM 0x04 HCI_EXT_TX_POWER_MINUS_9_DBM 0x05 HCI_EXT_TX_POWER_MINUS_6_DBM 0x06 HCI_EXT_TX_POWER_MINUS_3_DBM 0x07 HCI_EXT_TX_POWER_0_DBM 0x08 HCI_EXT_TX_POWER_1_DBM 0x09 HCI_EXT_TX_POWER_2_DBM 0x0A HCI_EXT_TX_POWER_3_DBM 0x0B HCI_EXT_TX_POWER_4_DBM 0x0C HCI_EXT_TX_POWER_5_DBM Page 28 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetTxPowerCmd has completed, a vendor specific Command Complete event shall be generated. Page 29 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.3 HCI Extension One Packet Per Event Command Opcode Command Parameters Return Parameters HCI_EXT_OnePktPerEvtCmd 0xFC02 control Status Description CC254x: CC264x: This command is used to configure the Link Layer to only allow one packet per connection event. The default system value for this feature is disabled. This command can be used to tradeoff throughput and power consumption during a connection. When enabled, power can be conserved during a connection by limiting the number of packets per connection event to one, at the expense of more limited throughput. When disabled, the number of packets transferred during a connection event is not limited, at the expense of higher power consumption. Command Parameters control: (1 byte) Value Parameter Description 0x00 HCI_EXT_DISABLE_ONE_PKT_PER_EVT 0x01 HCI_EXT_ENABLE_ONE_PKT_PER_EVT Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_OnePktPerEvtCmd has completed, a vendor specific Command Complete event shall be generated. Page 30 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.4 HCI Extension Clock Divide On Halt Command Opcode Command Parameters Return Parameters HCI_EXT_ClkDivOnHaltCmd 0xFC03 control Status Description CC254x: CC264x: This command is used to configure the Link Layer to divide the system clock when the MCU is halted during a radio operation. The default system value for this feature is disabled. Note: This command is only valid when the MCU is halted during RF operation (please see HCI_EXT_HaltDuringRfCmd). Command Parameters control: (1 byte) Value Parameter Description 0x00 HCI_EXT_DISABLE_CLK_DIVIDE_ON_HALT 0x01 HCI_EXT_ENABLE_CLK_DIVIDE_ON_HALT Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_ClkDivOnHaltCmd has completed, a vendor specific Command Complete event shall be generated. Page 31 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.5 HCI Extension Declare NV Usage Command Opcode Command Parameters Return Parameters HCI_EXT_DeclareNvUsageCmd 0xFC04 mode Status Description CC254x: CC264x: This command is used to inform the Controller whether the Host is using NV memory during BLE operations. The default system value for this feature is NV In Use. When the NV is not in use during BLE operations, the Controller is able to bypass internal checks that reduce overhead processing, thereby reducing average power consumption. Note: This command is only allowed when the BLE Controller is idle. Note: Using NV when declaring it is not in use may result in a hung BLE Connection. Command Parameters control: (1 byte) Value Parameter Description 0x00 HCI_EXT_NV_NOT_IN_USE 0x01 HCI_EXT_NV_IN_USE Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_DeclareNvUsageCmd has completed, a vendor specific Command Complete event shall be generated. Page 32 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.6 HCI Extension Decrypt Command Opcode Command Parameters Return Parameters HCI_EXT_DecryptCmd 0xFC05 key, encText Status Description CC254x: CC264x: This command is used to decrypt encrypted text using AES128. Command Parameters key: (16 bytes) Value Parameter Description 0xXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX 128 bit key for the decryption of the data given in the command. The most significant octet of the data corresponds to key[0] using the notation specified in FIPS 197. encText: (16 bytes) Value Parameter Description 0xXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX 128 bit encrypted data to be decrypted. The most significant octet of the key corresponds to key[0] using the notation specified in FIPS 197. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_DecryptCmd has completed, a vendor specific Command Complete event shall be generated. Page 33 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.7 HCI Extension Set Local Supported Features Command Opcode Command Parameters Return Parameters HCI_EXT_SetLocalSupportedFeaturesCmd 0xFC06 localFeatures Status Description CC254x: CC264x: This command is used to set the Controller’s Local Supported Features. For a complete list of supported LE features, please see [1], Part B, Section 4.6. Note: This command can be issued either before or after one or more connections are formed. However, the local features set in this manner are only effective if performed before a Feature Exchange Procedure has been initiated by the Master. Once this control procedure has been completed for a particular connection, only the exchanged feature set for that connection will be used. Since the Link Layer may initiate the feature exchange procedure autonomously, it is best to use this command before the connection is formed. Command Parameters localFeatures: (8 bytes) – CC254x Value Parameter Description 0x0000000000000001 Encryption Feature 0xFFFFFFFFFFFFFFFE Reserved for future use localFeatures: (8 bytes) – CC264x Value Parameter Description 0x0000000000000001 Encryption Feature 0x0000000000000002 Connection Parameters Request Feature 0x0000000000000004 Extended Reject Indication Feature 0x0000000000000008 Slave Features Exchange Feature 0x0000000000000010 Ping Feature 0xFFFFFFFFFFFFFFFE Reserved for future use Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetLocalSupportedFeaturesCmd has completed, a vendor specific Command Complete event shall be generated. Page 34 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.8 HCI Extension Set Fast Transmit Response Time Command Opcode Command Parameters Return Parameters HCI_EXT_SetFastTxResponseTimeCmd 0xFC07 control Status Description CC254x: CC264x: This command is used to configure the Link Layer fast transmit response time feature. The default system value for this feature is enabled. Note: This command is only valid for a Slave controller. When the Host transmits data, the controller (by default) ensures the packet is sent over the LL connection with as little delay as possible, even when the connection is configured to use slave latency. That is, the transmit response time will tend to be no longer than the connection interval. This results in lower power savings since the LL may need to wake to transmit during connection events that would normally have been skipped. If saving power is more critical than fast transmit response time, then this feature can be disabled using this command. When disabled, the transmit response time will be no longer than slave latency + 1 times the connection interval. Command Parameters control: (1 byte) Value Parameter Description 0x00 HCI_EXT_DISABLE_FAST_TX_RESP_TIME 0x01 HCI_EXT_ENABLE_FAST_TX_RESP_TIME Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetFastTxResponseTimeCmd has completed, a vendor specific Command Complete event shall be generated. Page 35 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.9 HCI Extension Modem Test Transmit Command Opcode Command Parameters Return Parameters HCI_EXT_ModemTestTxCmd 0xFC08 cwMode, txFreq Status Description CC254x: CC264x: This API is used to start a continuous transmitter modem test, using either a modulated or unmodulated carrier wave tone, at the frequency that corresponds to the specified RF channel. Use the HCI_EXT_EndModemTest command to end the test. Note: The RF channel, not the BLE frequency, is specified! You can obtain the RF channel from the BLE frequency as follows: RF Channel = (BLE Frequency – 2402) / 2. Note: When the HCI_EXT_EndModemTest is issued to stop this test, a Controller reset will take place. Note: The device will transmit at the default output power (0 dBm) unless changed by HCI_EXT_SetTxPowerCmd. Note: This modem test can be used to satisfy in part radio regulation requirements as specific in standards such as ARIB STD-T66. Command Parameters cwMode: (1 byte) Value Parameter Description 0x00 HCI_EXT_TX_MODULATED_CARRIER 0x01 HCI_EXT_TX_UNMODULATED_CARRIER t txFreq: (1 bytes) Value Parameter Description 0..39 RF channel of transmit frequency. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_ModemTestTxCmd has completed, a vendor specific Command Complete event shall be generated. Page 36 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.10 HCI Extension Modem Hop Test Transmit Command Opcode HCI_EXT_ModemHopTestTxCmd 0xFC09 Command Parameters Return Parameters Status Description CC254x: CC264x: This API is used to start a continuous transmitter direct test mode test using a modulated carrier wave and transmitting a 37 byte packet of pseudo-random 9 bit data. A packet is transmitted on a different frequency (linearly stepping through all RF channels 0..39) every 625us. Use the HCI_EXT_EndModemTest command to end the test. Note: When the HCI_EXT_EndModemTest is issued to stop this test, a Controller reset will take place. Note: The device will transmit at the default output power (0 dBm) unless changed by HCI_EXT_SetTxPowerCmd. Note: This modem test can be used to satisfy in part radio regulation requirements as specific in standards such as ARIB STD-T66. Command Parameters: None Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_ModemHopTestTxCmd has completed, a vendor specific Command Complete event shall be generated. Page 37 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.11 HCI Extension Modem Test Receive Command Opcode Command Parameters Return Parameters HCI_EXT_ModemTestRxCmd 0xFC0A rxFreq Status Description CC254x: CC264x: This API is used to start a continuous receiver modem test using a modulated carrier wave tone, at the frequency that corresponds to the specific RF channel. Any received data is discarded. Receiver gain may be adjusted using the HCI_EXT_SetRxGain command. RSSI may be read during this test by using the HCI_ReadRssi command. Use HCI_EXT_EndModemTest command to end the test. Note: The RF channel, not the BLE frequency, is specified! You can obtain the RF channel from the BLE frequency as follows: RF Channel = (BLE Frequency – 2402) / 2. Note: When the HCI_EXT_EndModemTest is issued to stop this test, a Controller reset will take place. Note: This modem test can be used to satisfy in part radio regulation requirements as specific in standards such as ARIB STD-T66. Command Parameters rxFreq: (1 bytes) Value Parameter Description 0..39 RF channel of receive frequency. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_ModemTestRxCmd has completed, a vendor specific Command Complete event shall be generated. Page 38 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.12 HCI Extension End Modem Test Command Opcode HCI_EXT_EndModemTestCmd 0xFC0B Command Parameters Return Parameters Status Description CC254x: CC264x: This API is used to end a modem test. A Controller reset will take place. Command Parameters None Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_EndModemTestCmd has completed, a vendor specific Command Complete event shall be generated. Page 39 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.13 HCI Extension Set BDADDR Command Opcode Command Parameters Return Parameters HCI_EXT_SetBDADDRCmd 0xFC0C bdAddr Status Description CC254x: CC264x: This command is used to set this device’s BLE address (BDADDR). This address will override the device’s address determined when the device is reset (i.e. a hardware reset, not an HCI Controller Reset). To restore the device’s initialized address, issue this command with an invalid address. Note: This command is only allowed when the Controller is in the Standby state. Note: This command is intended to only be used during initialization. Changing the device’s BDADDR after various BLE operations have already taken place may cause unexpected problems. Command Parameters bdAddr: (6 bytes) Value Parameter Description 0x000000000000.. Valid BLE device address. 0xFFFFFFFFFFFE 0xFFFFFFFFFFFF Invalid BLE device address. Used to restore the device address to that which was determined at initialization. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetBDADDRCmd has completed, a vendor specific Command Complete event shall be generated. Page 40 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.14 HCI Extension Set SCA Command Opcode Command Parameters Return Parameters HCI_EXT_SetSCACmd 0xFC0D scaInPPM Status Description CC254x: CC264x: This command is used to set this device’s Sleep Clock Accuracy (SCA) value, in parts per million (PPM), from 0 to 500. For a Master device, the value is converted to one of eight ordinal values representing a SCA range (per [1], Volume 6, Part B, Section 2.3.3.1, Table 2.2), which will be used when a connection is created. For a Slave device, the value is directly used. The system default value for a Master and Slave device is 50ppm and 40ppm, respectively. Note: This command is only allowed when the device is not in a connection. Note: The device’s SCA value remains unaffected by an HCI Reset. Command Parameters scaInPPM: (2 bytes) Value Parameter Description 0..0x1F4 Valid SCA value. 0x01F5..0xFFFF Invalid SCA value. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetSCACmd has completed, a vendor specific Command Complete event shall be generated. Page 41 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.15 HCI Extension Enable PTM Command Opcode HCI_EXT_EnablePTMCmd 0xFC0E Command Parameters Return Parameters Status Description CC254x: CC264x: This command is used to enable Production Test Mode (PTM). This mode is used by the customer during assembly of their product to allow limited access to the BLE Controller for testing and configuration. This command is only available when the BLE Controller is built without external access to the Controller (i.e. when no transport interface such as RS232 is permitted). This mode will remain enabled until the device is reset. Please see the related application note for additional details. Note: This command is only allowed as a direct function call, and is only intended to be used by an embedded application. No vendor specific Command Complete event will be generated. Command Parameters None Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED Event(s) Generated When the HCI_EXT_EnablePTMCmd has completed, it will simply return. No vendor specific Command Complete event will be generated. Page 42 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.16 HCI Extension Set Frequency Tuning Command Opcode Command Parameters Return Parameters HCI_EXT_SetFreqTuneCmd 0xFC0F step Status Description CC254x: CC264x: This PTM-only command is used to set this device’s Frequency Tuning either up one step or down one step. When the current setting is already at its max value, then stepping up will have no effect. When the current setting is already at its min value, then stepping down will have no effect. This setting will only remain in effect until the device is reset unless HCI_EXT_SaveFreqTuneCmd is used to save it in non-volatile memory. Command Parameters mode: (1 bytes) Value Parameter Description 0 HCI_PTM_SET_FREQ_TUNE_DOWN 1 HCI_PTM_SET_FREQ_TUNE_UP Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetFreqTuneCmd has completed, a vendor specific Command Complete event shall be generated. Page 43 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.17 HCI Extension Save Frequency Tuning Command Opcode HCI_EXT_SaveFreqTuneCmd 0xFC10 Command Parameters Return Parameters Status Description CC254x: CC264x: This PTM-only command is used to save this device’s Frequency Tuning setting in non-volatile memory. This setting will be used by the BLE Controller upon reset, and when waking from Sleep. Command Parameters None Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SaveFreqTuneCmd has completed, a vendor specific Command Complete event shall be generated. Page 44 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.18 HCI Extension Set Max DTM Transmitter Power Command Opcode Command Parameters Return Parameters HCI_EXT_SetMaxDtmTxPowerCmd 0xFC11 txPower Status Description CC254x: CC264x: This command is used to override the RF transmitter output power used by the Direct Test Mode (DTM). Normally, the maximum transmitter output power setting used by DTM is the maximum transmitter output power setting for the device (i.e. 4 dBm for the CC2540; 0 dBm for the CC2541; 5 dBm for the CC264x). This command will change the value used by DTM. Note: When DTM is ended by a call to HCI_LE_TestEndCmd, or a HCI_Reset is used, the transmitter output power setting is restored to the default value of 0 dBm. Command Parameters txPower: (1 byte) – CC254x Value Parameter Description 0x00 HCI_EXT_TX_POWER_MINUS_23_DBM 0x01 HCI_EXT_TX_POWER_MINUS_6_DBM 0x02 HCI_EXT_TX_POWER_0_DBM 0x03 HCI_EXT_TX_POWER_4_DBM (CC2540 only) txPower: (1 byte) - CC264x Value Parameter Description 0x00 HCI_EXT_TX_POWER_MINUS_21_DBM 0x01 HCI_EXT_TX_POWER_MINUS_18_DBM 0x02 HCI_EXT_TX_POWER_MINUS_15_DBM 0x03 HCI_EXT_TX_POWER_MINUS_12_DBM 0x04 HCI_EXT_TX_POWER_MINUS_9_DBM 0x05 HCI_EXT_TX_POWER_MINUS_6_DBM 0x06 HCI_EXT_TX_POWER_MINUS_3_DBM 0x07 HCI_EXT_TX_POWER_0_DBM 0x08 HCI_EXT_TX_POWER_1_DBM 0x09 HCI_EXT_TX_POWER_2_DBM 0x0A HCI_EXT_TX_POWER_3_DBM 0x0B HCI_EXT_TX_POWER_4_DBM 0x0C HCI_EXT_TX_POWER_5_DBM Page 45 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetMaxDtmTxPowerCmd has completed, a vendor specific Command Complete event shall be generated. Page 46 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.19 HCI Extension Map PM IO Port Command Opcode Command Parameters Return Parameters HCI_EXT_MapPmInOutPortCmd 0xFC12 ioPort, ioPin Status Description CC254x: CC264x: This command is used to configure and map a CC254x I/O Port as a General-Purpose I/O (GPIO) output signal that reflects the Power Management (PM) state of the CC254x device. The GPIO output will be High on Wake, and Low upon entering Sleep. This feature can be disabled by specifying HCI_EXT_PM_IO_PORT_NONE for the ioPort (ioPin is then ignored). The system default value upon hardware reset is disabled. This command can be used to control an external DC-DC Converter (its actual intent) such has the TI TPS62730 (or any similar converter that works the same way). This command should be used with extreme care as it will override how the Port/Pin was previously configured! This includes the mapping of Port 0 pins to 32kHz clock output, Analog I/O, UART, Timers; Port 1 pins to Observables, Digital Regulator status, UART, Timers; Port 2 pins to an external 32kHz XOSC. The selected Port/Pin will be configured as an output GPIO with interrupts masked. Careless use can result in a reconfiguration that could disrupt the system. For example, if the Port/Pin is being used as part of the serial interface for the device, the Port/Pin will be reconfigured from its original Peripheral function to a GPIO, disrupting the serial port. It is therefore the user’s responsibility to ensure the selected Port/Pin does not cause any conflicts in the system. Note: Only Pins 0, 3 and 4 are valid for Port 2 since Pins 1 and 2 are mapped to debugger signals DD and DC. Note: Port/Pin signal change will obviously only occur when Power Savings is enabled. Note: The CC254xEM modules map the TI TPS62730 control signal to P1.2, which happens to map to the SmartRF05EB LCD Chip Select. Thus, the LCD can’t be used when setup this way. Command Parameters ioPort: (1 byte) Value Parameter Description 0x00 HCI_EXT_PM_IO_PORT_P0 0x01 HCI_EXT_PM_IO_PORT_P1 0x02 HCI_EXT_PM_IO_PORT_P2 0xFF HCI_EXT_PM_IO_PORT_NONE ioPin: (1 byte) Value Parameter Description 0x00 HCI_EXT_PM_IO_PORT_PIN0 0x01 HCI_EXT_PM_IO_PORT_PIN1 0x02 HCI_EXT_PM_IO_PORT_PIN2 Page 47 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0x03 HCI_EXT_PM_IO_PORT_PIN3 0x04 HCI_EXT_PM_IO_PORT_PIN4 0x05 HCI_EXT_PM_IO_PORT_PIN5 0x06 HCI_EXT_PM_IO_PORT_PIN6 0x07 HCI_EXT_PM_IO_PORT_PIN7 Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_MapPmIoPortCmd has completed, a vendor specific Command Complete event shall be generated. Page 48 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.20 HCI Extension Disconnect Immediate Command Opcode Command Parameters Return Parameters HCI_EXT_DisconnectImmedCmd 0xFC13 connHandle Status Description CC254x: CC264x: This command is used to disconnect a connection immediately. This command can be useful for when a connection needs to be ended without the latency associated with the normal BLE Controller Terminate control procedure. Note that the Host issuing the command will still receive the HCI Disconnection Complete event with a Reason status of 0x16 (i.e. Connection Terminated by Local Host), followed by an HCI Vendor Specific Event. Command Parameters connHandle: (2 bytes) Value 0x0000 .. 0x0EFF Parameter Description Connection Handle to be used to identify a connection. Note: 0x0F00 – 0x0FFF are reserved for future use. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_DisconnectImmedCmd has completed, an HCI Disconnection Complete event followed by a vendor specific Command Complete event shall be generated. Page 49 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.21 HCI Extension Packet Error Rate Command Opcode Command Parameters Return Parameters HCI_EXT_PacketErrorRateCmd 0xFC14 connHandle, command Status Description CC254x: CC264x: This command is used to Reset or Read the Packet Error Rate counters for a connection. When Reset, the counters are cleared; when Read, the total number of packets received, the number of packets received with a CRC error, the number of events, and the number of missed events are returned. The system default value upon hardware reset is Reset. Note: The counters are only 16 bits. At the shortest connection interval, this provides a little over 8 minutes of data. Note: This command is only valid for a valid connection handle (i.e. for an active connection). It is therefore not possible to read the packet error rate data once the connection has ended. Command Parameters connHandle: (2 bytes) Value 0x0000 .. 0x0EFF Parameter Description Connection Handle to be used to identify a connection. Note: 0x0F00 – 0x0FFF are reserved for future use. command: (1 byte) Value Parameter Description 0x00 HCI_EXT_PER_RESET 0x01 HCI_EXT_PER_READ Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_PacketErrorRateCmd has completed, a vendor specific Command Complete event followed by a vendor specific Command Complete event shall be generated. Page 50 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.22 HCI Extension Packet Error Rate By Channel Command Opcode Command Parameters Return Parameters HCI_EXT_PERbyChanCmd 0xFC15 connHandle, *perByChan Status Description CC254x: CC264x: This command is used to start or end Packet Error Rate by Channel counter accumulation for a connection, and can be used by an application to make Coexistence assessments. Based on the results, an application can perform an Update Channel Classification command to limit channel interference from other wireless standards. If *perByChan is NULL, counter accumulation will be discontinued. If *perByChan is not NULL, then it is assumed that there is sufficient memory for the PER data, based on the following type definition perByChan_t located in ll.h: #define LL_MAX_NUM_DATA_CHAN 37 // Packet Error Rate Information By Channel typedef struct { uint16 numPkts[ LL_MAX_NUM_DATA_CHAN ]; uint16 numCrcErr[ LL_MAX_NUM_DATA_CHAN ]; } perByChan_t; Note: This command is only allowed as a direct function call, and is only intended to be used by an embedded application. Note: It is the user’s responsibility to ensure there is sufficient memory allocated! The user is also responsible for maintaining the counters, clearing them if required before starting accumulation. Note: As indicated, the counters are 16 bits. At the shortest connection interval, this provides a bit over 8 minutes of data. Note: This command can be used in combination with HCI_EXT_PacketErrorRateCmd. Command Parameters connHandle: (2 bytes) Value 0x0000 .. 0x0EFF Parameter Description Connection Handle to be used to identify a connection. Note: 0x0F00 – 0x0FFF are reserved for future use. *perByChan: (2 bytes) Value Parameter Description NULL Non-NULL End counter accumulation. Start counter accumulation by channel. Page 51 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_PERbyChanCmd has completed, a vendor specific Command Complete event shall be generated. Page 52 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.23 HCI Extension Extend RF Range Command Opcode HCI_EXT_ExtendRfRangeCmd 0xFC16 Command Parameters Return Parameters Status Description CC254x: CC264x: This command is used to configure the CC254x to automatically control the TI CC2590 2.4GHz RF Front End device. Using the CC2590 allows a maximum Tx output power of 10dBm (the specified BLE maximum), and increases Rx sensitivity, thus extending the RF range of the CC254x. Once this command is used, the configuration will not change unless the CC254x is reset. Automatic control of the CC2590 is achieved using the CC254x Observables, which take control of GPIO P1.2 and P1.3. The GPIO P1.1 is also taken to control RF gain. These GPIOs are therefore not available when using this feature. This command can be used in combination with HCI_EXT_SetTxPowerCmd, resulting in a cumulative Tx output power. Therefore, for the CC2540 only, attempting to set Tx output power to 4dBm (i.e. using HCI_EXT_TX_POWER_4_DBM), will instead set the Tx output power to 0dBm. The command HCI_EXT_SetRxGainCmd should be used to set the Rx gain per usual. That is, the CC254x Rx Standard/High gain setting is mirrored to the CC2590 High Gain Mode (HGM) Low/High setting. When this command is used, the CC254x Tx output power and Rx gain will retain their previous values, unless the previous Tx output power value was set to 4dBm on the CC2540. In this case, as previously explained, the value will be set to 0dBm. Command Parameters None Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_ExtendRfRangeCmd has completed, a vendor specific Command Complete event shall be generated. Page 53 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.24 HCI Extension Advertiser Event Notice Command Opcode Command Parameters Return Parameters HCI_EXT_AdvEventNoticeCmd 0xFC17 taskID, taskEvent Status Description CC254x: CC264x: This command is used to configure the device to set a user task’s event when an Advertisement event completes. Only a single task event value is allowed (i.e. must be a power of two). A non-zero taskEvent value is taken to be "enable", while a zero valued taskEvent is taken to be "disable". The default value is “disable”. Note: This command is only allowed as a direct function call, and is only intended to be used by an embedded application. No vendor specific Command Complete event will be generated. Command Parameters taskID: (1 byte) Value 0x00..0xFF Parameter Description OSAL task ID. taskEvent: (2 bytes) Value 0 14 2 ..2 Parameter Description 15 OSAL task event. Note that 2 is a reserved system task event. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS Event(s) Generated When the HCI_EXT_AdvEventNoticeCmd has completed, it will simply return. No vendor specific Command Complete event will be generated. Page 54 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.25 HCI Extension Connection Event Notice Command Opcode Command Parameters Return Parameters HCI_EXT_ConnEventNoticeCmd 0xFC18 connHandle, taskID, taskEvent Status Description CC254x: CC264x: This command is used to configure the device to set a user task’s event when a Connection event completes. Only a single task event value is allowed (i.e. must be a power of two). A non-zero taskEvent value is taken to be "enable", while a zero valued taskEvent is taken to be "disable". The default value is “disable”. Note: This command does not check if the taskID and/or taskEvent are valid! Note: This feature is automatically disabled once the connection ends, and therefore this command must be called each time another connection is formed in order to continue its use. Note: This command is only allowed as a direct function call, and is only intended to be used by an embedded application. No vendor specific Command Complete event will be generated. Command Parameters connHandle: (2 byte, 12 bits meaningful) Value 0xXXXX Parameter Description Identifies the connection to which this event notice applies. Range: 0x0000-0x0EFF (0x0F00-0x0FFF Reserved for future use). taskID: (1 byte) Value Parameter Description 0x00..0xFF OSAL task ID. taskEvent: (2 bytes) Value 0 14 2 ..2 Parameter Description OSAL task event. Note that 2 15 is a reserved system task event. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x02 HCI_ERROR_CODE_UNKNOWN_CONN_ID 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS Page 55 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event(s) Generated When the HCI_EXT_ConnEventNoticeCmd has completed, it will simply return. No vendor specific Command Complete event will be generated. 10.26 HCI Extension Halt During RF Command Opcode Command Parameters Return Parameters HCI_EXT_HaltDuringRfCmd 0xFC19 mode Status Description CC254x: CC264x: This command is used to enable or disable the halting of the MCU while the radio is operating. When the MCU is not halted, the peak current is higher, but the system is more responsive. When the MCU is halted, the peak current consumption is reduced, but the system is less responsive. The default value is Enable. Note: This command will be disallowed if there are any active BLE connections. Note: The HCI_EXT_ClkDivOnHaltCmd will be disallowed if the halt during RF is not enabled. Command Parameters mode: (1 byte) Value Parameter Description 0x00 HCI_EXT_HALT_DURING_RF_DISABLE 0x01 HCI_EXT_HALT_DURING_RF_ENABLE Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_HaltDuringRfCmd has completed, a vendor specific Command Complete event shall be generated. Page 56 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.27 HCI Extension Set Slave Latency Override Command Opcode Command Parameters Return Parameters HCI_EXT_SetSlaveLatencyOverrideCmd 0xFC1A mode Status Description CC254x: CC264x: This command is used to enable or disable the Slave Latency Override, allowing the user to ensure that Slave Latency is not applied even though it is active. The default value is Disable. Note: This command will be disallowed for no connection, or the connection is not in the Slave role. Command Parameters mode: (1 byte) Value Parameter Description 0x00 HCI_EXT_DISABLE_SL_OVERRIDE 0x01 HCI_EXT_ENABLE_SL_OVERRIDE Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_SetSlaveLatencyOverrideCmd has completed, a vendor specific Command Complete event shall be generated. Page 57 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.28 HCI Extension Build Revision Command Opcode Command Parameters Return Parameters HCI_EXT_BuildRevisionCmd 0xFC1B mode, userRevNum Status Description CC254x: CC264x: This command is used to a) allow the embedded user code to set their own 16 bit revision number, and b) to read the build revision number of the BLE stack library software. The default value of the user revision number is zero. When the user updates a BLE project by adding their own code, they may use this API to set their own revision number. When called with mode set to HCI_EXT_SET_APP_REVISION, the stack will save this value. No event will be returned from this API when used this way as it is intended to be called from within the target itself. Note however that this does not preclude this command from being received via the HCI. However, no event will be returned. When this API is used from the HCI, then the second parameter is ignored, and a vendor specific event is returned with the user’s revision number and the build revision number of the BLE stack. Command Parameters mode: (1 byte) Value Parameter Description 0x00 HCI_EXT_SET_APP_REVISION 0x01 HCI_EXT_READ_BUILD_REVISION userRevNum: (2 bytes) Value 0xXXXX Parameter Description Any 16 bit value the application wishes to use as their revision number. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_BuildRevisionCmd has completed, a vendor specific Command Complete event shall be generated, but only when the value of mode is HCI_EXT_READ_BUILD_REVISION. Page 58 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.29 HCI Extension Delay Sleep Command Opcode Command Parameters Return Parameters HCI_EXT_DelaySleepCmd 0xFC1C delay Status Description CC254x: CC264x: This command is used to set the delay before sleep occurs after Reset or upon waking from sleep to allow the external 32kHz crystal to stabilize. If this command is never used, the default delay is 400ms on the CC254x. This command is no longer supported on the CC264x platform. If the customer’s hardware requires a different delay or does not require this delay at all, it can be changed by calling this command during their OSAL task initialization. A zero delay value will eliminate the delay after Reset and (unless changed again) all subsequent wakes from sleep; a non-zero delay value will change the delay after Reset and (unless changed again) all subsequent wakes from sleep. If this command is used any time after system initialization, then the new delay value will be applied the next time the delay is used. Note: This delay only applies to Reset and Sleep. If a periodic timer is used, or a BLE operation is active, then only Sleep is used, and this delay will only occur after Reset. Note: There is no distinction made between a hard and soft reset. The delay (if non-zero) will be applied the same way in either case. Command Parameters delay: (2 bytes) Value Parameter Description 0x0000..0x03E8 In milliseconds. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_DelaySleepCmd has completed, a vendor specific Command Complete event shall be generated. Page 59 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.30 HCI Extension Reset System Command Opcode Command Parameters Return Parameters HCI_EXT_ResetSystemCmd 0xFC1D mode Status Description CC254x: CC264x: (Hard Reset Only) This command is used to issue a hard or soft system reset. On the CC254x, a hard reset is caused by a watchdog timer timeout, while a soft reset is caused by resetting the PC to zero. On the CC264x, a hard reset is caused by setting the SYSRESET bit in the System Controller Reset Control register. The soft reset is currently not supported on the CC264x. Command Parameters mode: (1 byte) Value Parameter Description 0x00 HCI_EXT_RESET_SYSTEM_HARD 0x01 HCI_EXT_RESET_SYSTEM_SOFT (CC254x only) Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_ResetSystemCmd has completed, a vendor specific Command Complete event shall be generated. Page 60 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.31 HCI Extension Overlapped Processing Command Opcode Command Parameters Return Parameters HCI_EXT_OverlappedProcessingCmd 0xFC1E mode Status Description CC254x: CC264x: This command is used to enable or disable overlapped processing. The default is disabled. Command Parameters mode: (1 byte) Value Parameter Description 0x00 HCI_EXT_DISABLE_OVERLAPPED_PROCESSING 0x01 HCI_EXT_ENABLE_OVERLAPPED_PROCESSING Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_OverlappedProcessingCmd has completed, a vendor specific Command Complete event shall be generated. Page 61 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.32 HCI Extension Number Completed Packets Limit Command Opcode Command Parameters Return Parameters HCI_EXT_NumComplPktsLimitCmd 0xFC1F limit, flushOnEvt Status Description CC254x: CC264x: This command is used to set the limit on the minimum number of complete packets before a Number of Completed Packets event is returned by the Controller. If the limit is not reached by the end of a connection event, then the Number of Completed Packets event will be returned (if non-zero) based on the flushOnEvt flag. The limit can be set from one to the maximum number of HCI buffers (please see the LE Read Buffer Size command in the Bluetooth Core specification). The default limit is one; the default flushOnEvt flag is FALSE. Command Parameters limit: (1 byte) Value Parameter Description 0x01..Where is returned by HCI_LE_ReadBufSizeCmd. flushOnEvt: (1 byte) Value 0x00 0x01 Parameter Description Only return a Number of Completed Packets event when the number of completed packets is greater than or equal to the limit. Return a Number of Complete Packets event if the number of completed packets is less than the limit. Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_NumComplPktsLimitCmd has completed, a vendor specific Command Complete event shall be generated. Page 62 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 10.33 HCI Extension Get Connection Information Command Opcode Command Parameters Return Parameters HCI_EXT_GetConnInfoCmd 0xFC20 *numAllocConns, *numActiveConns, *activeConnInfo Status Description CC254x: CC264x: This command (which replaces Get Number Connections) is used to get the number of allocated connections, the number of active connections, and for each active connection, the connection handle, the connection role, the peer device address and peer device address type. The number of allocated connections is based on a default build value that can be changed in the project using MAX_NUM_BLE_CONNS (please see the software user’s guide for additional details). The number of active connections refers to active BLE connections. The information per connection is based on the structure hciConnInfo_t provided in hci.h. If all parameters are NULL, then the call to this command is considered a network processor call via a transport layer, and the results will be provided via a vendor specific command complete event. If any parameter is not NULL, then the call to this command is considered a direct function call and the valid pointers will be used to store the result. In this case, it is the user’s responsibility to ensure there is sufficient memory allocated! Note that partial results can be obtained by selective use of the pointers. For example, if only the number of active connections is desired, this can be obtained as follows: uint8 numActiveConns; (void)HCI_EXT_GetConnInfoCmd( NULL, &numActiveConns, NULL ); Command Parameters *numAllocConns: (1 byte) Value Parameter Description NULL Invalid pointer. Non-NULL Pointer for the number of allocated connections (1 byte). *numActiveConns: (1 byte) Value Parameter Description NULL Invalid pointer. Non-NULL Pointer for the number of active connections (1 byte). Page 63 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide *activeConnInfo: (N bytes) Value Parameter Description NULL Invalid pointer. Pointer for the connection information for each active connection, which consists of: Connection ID, Connection Role, Peer Device Address, and Peer Address Type, which will require (Number Of Active Connections * 9 bytes) of memory. Non-NULL Return Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS Event(s) Generated When the HCI_EXT_GetConnInfoCmd has completed, a vendor specific Command Complete event shall be generated if all command parameters were NULL. Page 64 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11. HCI Extension Vendor Specific Events The HCI Extension vendor specific commands generate the following vendor specific events. Please see the corresponding command to determine whether this event is supported on the CC254x and/or CC264x. 11.1 HCI Extension Set Receiver Gain Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0400 Status, cmdOpcode Description This event is sent to indicate the RF receiver gain has been set, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC00 HCI Extension Set Receiver Gain Command 11.2 HCI Extension Set Transmitter Power Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0401 Status, cmdOpcode Description This event is sent to indicate the RF transmitter power has been set, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC01 HCI Extension Set Transmitter Power Command Page 65 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.3 HCI Extension One Packet Per Event Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0402 Status, cmdOpcode Description This event is sent to indicate the One Packet Per Event feature has been enabled or disabled, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC02 HCI Extension One Packet Per Event Command 11.4 HCI Extension Clock Divide On Halt Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0403 Status, cmdOpcode Description This event is sent to indicate the Clock Divide On Halt feature has been enabled or disabled, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC03 HCI Extension Clock Divide On Halt Command Page 66 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.5 HCI Extension Declare NV Usage Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0404 Status, cmdOpcode Description This event is sent to indicate the Declare NV Usage feature has been set, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC04 HCI Extension Declare NV Usage Command 11.6 HCI Extension Decrypt Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0405 Status, cmdOpcode, plainTextData Description This event is sent to indicate Decryption has completed. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS cmdOpcode: (2 bytes) Value Parameter Description 0xFC05 HCI Extension Decrypt Command plainTextData: (16 bytes) Value Parameter Description 0xXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX 128 bit decrypted data block. The most significant octet of plainTextData corresponds to plainTextData [0] using the notation specified in FIPS 197. Page 67 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.7 HCI Extension Set Local Supported Features Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0406 Status, cmdOpcode Description This event is sent to indicate the Set Local Supported Features command has completed. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS cmdOpcode: (2 bytes) Value Parameter Description 0xFC06 HCI Extension Set Local Supported Features Command 11.8 HCI Extension Set Fast Transmit Response Time Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0407 Status, cmdOpcode Description This event is sent to indicate the Set Fast Transmit Response Time feature has been enabled or disabled, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC07 HCI Extension Set Fast Transmit Response Time Command Page 68 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.9 HCI Extension Modem Test Transmit Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0408 Status, cmdOpcode Description This event is sent to indicate the Modem Test Transmit test has started, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS 0x21 HCI_ERROR_CODE_ROLE_CHANGE_NOT_ALLOWED cmdOpcode: (2 bytes) Value Parameter Description 0xFC08 HCI Extension Modem Test Transmit Command 11.10 HCI Extension Modem Hop Test Transmit Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0409 Status, cmdOpcode Description This event is sent to indicate the Modem Hop Test Transmit test has started, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x21 HCI_ERROR_CODE_ROLE_CHANGE_NOT_ALLOWED cmdOpcode: (2 bytes) Value Parameter Description 0xFC09 HCI Extension Modem Hop Test Transmit Command Page 69 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.11 HCI Extension Modem Test Receive Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x040A Status, cmdOpcode Description This event is sent to indicate the Modem Test Receive test has started, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS 0x21 HCI_ERROR_CODE_ROLE_CHANGE_NOT_ALLOWED cmdOpcode: (2 bytes) Value Parameter Description 0xFC0A HCI Extension Modem Test Receive Command 11.12 HCI Extension End Modem Test Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x040B Status, cmdOpcode Description This event is sent to indicate the modem test has been shutdown, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x21 HCI_ERROR_CODE_ROLE_CHANGE_NOT_ALLOWED cmdOpcode: (2 bytes) Value Parameter Description 0xFC0B HCI Extension End Modem Test Command Page 70 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.13 HCI Extension Set BDADDR Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x040C Status, cmdOpcode Description This event is sent to indicate the device’s BLE address has been set, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC0C HCI Extension Set BDADDR Command 11.14 HCI Extension Set SCA Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x040D Status, cmdOpcode Description This event is sent to indicate the device’s SCA has been set, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC0D HCI Extension Set SCA Command Page 71 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.15 HCI Extension Enable PTM There is not a corresponding event opcode (0x040E) and parameters for this command as it is only allowed as a direct function call by the application software. 11.16 HCI Extension Set Frequency Tuning Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x040F Status, cmdOpcode Description This event is sent to indicate the device’s frequency tuning value has be adjusted one step up or down, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC0F HCI Extension Set Frequency Tuning Command 11.17 HCI Extension Save Frequency Tuning Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0410 Status, cmdOpcode Description This event is sent to indicate the device’s current frequency tuning value has been saved to non-volatile memory, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED Page 72 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide cmdOpcode: (2 bytes) Value Parameter Description 0xFC10 HCI Extension Save Frequency Tuning Command 11.18 HCI Extension Set Max DTM Transmitter Power Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0411 Status, cmdOpcode Description This event is sent to indicate the maximum Direct Test Mode (DTM) RF transmitter power has been set, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC11 HCI Extension Set Transmitter Power Command 11.19 HCI Extension Map PM IO Port Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0412 Status, cmdOpcode Description This event is sent to indicate the PM IO Port has been configured and mapped, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS Page 73 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide cmdOpcode: (2 bytes) Value Parameter Description 0xFC12 HCI Extension Map PM IO Port Command 11.20 HCI Extension Disconnect Immediate Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0413 Status, cmdOpcode Description This event is sent to indicate the Disconnect Immediate command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x02 HCI_ERROR_CODE_UNKNOWN_CONN_ID 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC13 HCI Extension Disconnect Immediate Command 11.21 HCI Extension Packet Error Rate Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0414 Status, cmdOpcode, cmdVal, numPkts, numCrcErr, numEvents, numMissedEvts Description This event is sent to indicate the Packet Error Rate Reset or Read command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x02 HCI_ERROR_CODE_UNKNOWN_CONN_ID 0x0C HCI_ERROR_CODE_CMD_DISALLOWED Page 74 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC14 HCI Extension Packet Error Rate Command cmdVal: (2 bytes) Value Parameter Description 0x00 HCI_EXT_PER_RESET 0x01 HCI_EXT_PER_READ Note: The following event parameters are for the Read command only. numPkts: (2 bytes) Value Parameter Description 0x0000 .. 0xFFFF Total number of received packets. numCrcErr: (2 bytes) Value Parameter Description 0x0000 .. 0xFFFF Number of received packets with CRC error. numEvents: (2 bytes) Value Parameter Description 0x0000 .. 0xFFFF Number of connection events. numMissedEvents: (2 bytes) Value Parameter Description 0x0000 .. 0xFFFF Number of missed connection events. 11.22 HCI Extension Packet Error Rate By Channel Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0415 Status, cmdOpcode Description Page 75 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide This event is sent to indicate the Packet Error Rate By Channel command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x02 HCI_ERROR_CODE_UNKNOWN_CONN_ID cmdOpcode: (2 bytes) Value Parameter Description 0xFC15 HCI Extension Packet Error Rate By Channel Command 11.23 HCI Extension Extend RF Range Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0416 Status, cmdOpcode Description This event is sent to indicate the Extend RF Range command has completed. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS cmdOpcode: (2 bytes) Value Parameter Description 0xFC16 HCI Extension Extend RF Range Command 11.24 HCI Extension Advertiser Event Notice There is not a corresponding event opcode (0x0417) and parameters for this command as it is only allowed as a direct function call by the application software. 11.25 HCI Extension Connection Event Notice There is not a corresponding event opcode (0x0418) and parameters for this command as it is only allowed as a direct function call by the application software. Page 76 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.26 HCI Extension Halt During RF Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0419 Status, cmdOpcode Description This event is sent to indicate the Halt During RF feature has been enabled or disabled, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC19 HCI Extension Halt During RF Command 11.27 HCI Extension Set Slave Latency Override Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x041A Status, cmdOpcode Description This event is sent to indicate the Set Slave Latency Override feature has been enabled or disabled, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x0C HCI_ERROR_CODE_CMD_DISALLOWED 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC1A HCI Extension Set Slave Latency Override Command Page 77 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.28 HCI Extension Build Revision Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x041B Status, cmdOpcode, userRevNum, buildRevNum Description This event is sent to indicate the user revision number and the build revision of the stack, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC1B HCI Extension Build Revision Command userRevNum: (2 bytes) Value Parameter Description 0xXXXX The user revision number set by the application software. If no value was ever set, than 0x0000. buildRevNum: (2 bytes) Value Parameter Description 0xXXXX The build revision number of the BLE stack. 11.29 HCI Extension Delay Sleep Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x041C Status, cmdOpcode Description This event is sent to indicate the Delay Sleep command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description Page 78 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC1C HCI Extension Delay Sleep Command 11.30 HCI Extension Reset System Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x041D Status, cmdOpcode Description This event is sent to indicate the Reset System command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC1D HCI Extension Reset System Command Page 79 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.31 HCI Extension Overlapped Processing Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x041E Status, cmdOpcode Description This event is sent to indicate the Overlapped Processing command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC1E HCI Extension Overlapped Processing Command 11.32 HCI Extension Number Completed Packets Limit Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x041F Status, cmdOpcode Description This event is sent to indicate the Number Completed Packets Limit command has completed, or that there was an error. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x12 HCI_ERROR_CODE_INVALID_HCI_CMD_PARAMS cmdOpcode: (2 bytes) Value Parameter Description 0xFC1F HCI Extension Number Complete Packets Limit Command Page 80 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 11.33 HCI Extension Get Connection Information Event Opcode Event Parameters HCI_Vendor_Specific_Event 0x0420 Status, cmdOpcode, numAllocConns, numActiveConns, activeConnInfo Description This event is sent to indicate the Get Connection Information command has completed. Event Parameters Status: (1 byte) Value Parameter Description 0x00 HCI_SUCCESS 0x07 HCI_ERROR_CODE_MEM_CAP_EXCEEDED cmdOpcode: (2 bytes) Value Parameter Description 0xFC20 HCI Extension Get Number Connections Command numAllocConns: (1 byte) Value Parameter Description 0..0xFF Number of allocated connections. numActiveConns: (1 byte) Value Parameter Description 0..0xFF Number of active connections. activeConnInfo: (N bytes) Value 0..0xFF Parameter Description For each active connection: Connection ID, Connection Role, Peer Device Address, and Peer Address Type (Number Of Active Connections * 9 bytes). Page 81 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 12. GAP Vendor Specific Commands 12.1 GAP Device Initialization Command Opcode Command Parameters Return Parameters GAP_DeviceInit 0xFE00 profileRole, maxScanResponses, IRK, CSRK, signCounter Status Description: This command is used to setup the device in a GAP Role and should only be called once per reboot. To enable multiple combinations setup multiple GAP Roles (profileRole parameter). Multiple Role settings examples: GAP_PROFILE_PERIPHERAL and GAP_PROFILE_BROADCASTER – allows a connection and advertising (non-connectable) at the same time. GAP_PROFILE_PERIPHERAL and GAP_PROFILE_OBSERVER – allows a connection (with master) and scanning at the same time. GAP_PROFILE_PERIPHERAL, GAP_PROFILE_OBSERVER and GAP_PROFILE_BROADCASTER – allows a connection (with master) and scanning or advertising at the same time. GAP_PROFILE_CENTRAL and GAP_PROFILE_BROADCASTER – allows connections and advertising (non-connectable) at the same time. Note: If the device’s BLE address (BDADDR) is to be set then this command must be executed after HCI_EXT_SetBDADDRCmd for the generated security keys to be valid. Command Parameters: profileRole: Bit Mask (1 octet) Value Parameter Description 0x01 GAP_PROFILE_BROADCASTER 0x02 GAP_PROFILE_OBSERVER 0x04 GAP_PROFILE_PERIPHERAL 0x08 GAP_PROFILE_CENTRAL maxScanResponses: (1 octet) Range Parameter Description 0 – 0xFF Central or Observer only: The device will allocate buffer space for received advertisement packets. The default is 3. The larger the number, the more RAM that is needed and maintained. Page 82 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide IRK: (16 octets) Range Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Identity Resolving Key (IRK). If this value is all 0’s, the GAP will randomly generate all 16 bytes. This key is used to generate Resolvable Private Addresses. CSRK: (16 octets) Range Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Connection Signature Resolving Key (CSRK). If this value is all 0’s, the GAP will randomly generate all 16 bytes. This key is used to generate data Signatures. signCounter: (4 octets) Range Parameter Description 0x00000000 – 0xFFFFFFFF 32 bit Signature Counter. Initial signature counter. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 INVALIDPARAMETER Event(s) Generated: When device initialization is received, the host will send the HCI Ext Command Status Event with the Status parameter. When initialization task is complete, the host will send the GAP Device Init Done Event. 12.2 GAP Configure Device Address Command Opcode Command Parameters Return Parameters GAP_ConfigDeviceAddr 0xFE03 addrType, Addr Status Description: Send this command to set the device’s address type. If ADDRTYPE_PRIVATE_RESOLVE is selected, the address will change periodically. Page 83 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Command Parameters: addrType: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE Addr: (6 octet) Range Parameter Description “XX:XX:XX:XX:XX:XX” Intended address. Only used with ADDRTYPE_STATIC or ADDRTYPE_PRIVATE_NONRESOLVE. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 INVALIDPARAMETER 0x10 GAP_DeviceInit must be completed first. 0x12 Address type can’t be change during an active connection. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. If ADDRTYPE_PRIVATE_RESOLVE addrType is selected, the GAP Random Address Changed Event will be generated when the address is automatically updated. 12.3 GAP Device Discovery Request Command Opcode Command Parameters Return Parameters GAP_DeviceDiscoveryRequest 0xFE04 mode, activeScan, whiteList Status Description: Send this command to start a scan for advertisement packets. This command is valid for a central or a peripheral device. Page 84 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Command Parameters: mode: (1 octet) Value Parameter Description 0 Non-Discoverable Scan 1 General Mode Scan 2 Limited Mode Scan 3 Scan for all devices activeScan: (1 octet) Value Parameter Description 0 Turn off active scanning (SCAN_REQ) 1 Turn on active scanning (SCAN_REQ) whiteList: (1 octet) Value Parameter Description 0 Don’t use the white list during a scan 1 Use the white list during a scan Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x11 Scan is not available. 0x12 Invalid profile role. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. During the scan, the device will generate GAP Device Information Events for advertising devices, then issue a GAP Device Discovery Event when the scan is completed. 12.4 GAP Device Discovery Cancel Command Opcode GAP_DeviceDiscoveryCancel 0xFE05 Command Parameters Return Parameters Status Page 85 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: Send this command to end a scan for advertisement packets. This command is valid for a central or a peripheral device. Command Parameters: None Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x11 Scan is not available. 0x12 Invalid profile role. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter, then issue a GAP Device Discovery Event to display the scan progress since the start of the scan. 12.5 GAP Make Discoverable Command Opcode Command Parameters Return Parameters GAP_MakeDiscoverable 0xFE06 eventType, initiatorAddrType, initiatorAddr, channelMap, filterPolicy Status Description: Send this command to start the device advertising. Command Parameters: eventType: (1 octet) Value Parameter Description 0 Connectable undirected advertisement Page 86 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 1 Connectable directed advertisement 2 Discoverable undirected advertisement 3 Non-connectable undirected advertisement initiatorAddrType: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE initiatorAddr: (6 octet) Range Parameter Description “XX:XX:XX:XX:XX:XX” Intended address. Only used for directed advertisments channelMap: Bit Mask (1 octet) Bit Definitions Parameter Description 0 Channel 37 1 Channel 38 2 Channel 39 3–7 reserved filterPolicy: (1 octet) Value Parameter Description 0 Allow scan requests from any, allow connect request from any. 1 Allow scan requests from white list only, allow connect request from any. 2 Allow scan requests from any, allow connect request from white list only. 3 Allow scan requests from white list only, allow connect requests from white list only. 4 – 0xFF reserved Page 87 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x10 Advertising data isn’t setup. 0x11 Not available at this time. 0x12 Invalid profile role. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter, then, when the device starts advertising the GAP Make Discoverable Done Event is generated. When advertising is completed (limited mode advertising has a time limit), the GAP End Discoverable Event is generated. 12.6 GAP Update Advertising Data Command Opcode Command Parameters Return Parameters GAP_UpdateAdvertisingData 0xFE07 adType, dataLen, advertData Status Description: Send this command to set the raw advertising or scan response data. Command Parameters: adType: (1 octet) Value Parameter Description 0 SCAN_RSP data 1 Advertisement data dataLen: (1 octet) Range Parameter Description 0 – 31 Length of the advertData field (in octets) advertData: (dataLen octets) Value Parameter Description “XX:XX … XX” Raw advertising data Page 88 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x12 Invalid profile role. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter, then, when the task is complete the GAP Advert Data Update Done Event is generated. 12.7 GAP End Discoverable Command Opcode GAP_EndDiscoverable 0xFE08 Command Parameters Return Parameters Status Description: Send this command to end advertising. Command Parameters: None Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x12 Not advertising Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter, then issue a GAP End Discoverable Done Event advertising has stopped. 12.8 GAP Establish Link Request Page 89 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Command Opcode Command Parameters Return Parameters GAP_EstablishLinkReq 0xFE09 highDutyCycle, whiteList, addrTypePeer, peerAddr Status Description: Send this command to initiate a connection with a peripheral device. Only central devices can issue this command. Command Parameters: highDutyCycle: (1 octet) Value Parameter Description 0 disabled 1 enabled A central device may use high duty cycle scan parameters in order to achieve low latency connection time with a peripheral device using directed link establishment. whiteList: (1 octet) Value Parameter Description 0 Don’t use the white list 1 Only connect to a device in the white list addrTypePeer: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE peerAddr: (6 octet) Range Parameter Description “XX:XX:XX:XX:XX:XX” Peripheral address to connect with. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS Page 90 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x10 Not ready to perform this action. Performing a scan. 0x12 Invalid profile role. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. When the connection has been made, the GAP Link Established Event will be generated. 12.9 GAP Terminate Link Request Command Opcode Command Parameters Return Parameters GAP_TerminateLinkReq 0xFE0A connHandle, reason Status Description: Send this command to terminate a connection link, a connection request or all connected links. Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Existing connection handle to terminate 0xFFFE Terminate the “Establish Link Request” 0xFFFF Terminate all links reason: (1 octet) Value Parameter Description 0x05 Authentication Failure 0x13 Remote User Terminated Connection 0x14 Remote Device Terminated Connection Due To Low Resources 0x15 Remote Device Terminated Connection due to Power Off 0x1A Unsupported Remote Feature 0x29 Pairing With Unit Key Not Supported 0x3B Unacceptable Connection Interval Return Parameters: Page 91 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x12 No link to terminate Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. When the connection is terminated, the GAP Link Terminated Event will be generated. 12.10 GAP Authenticate Command Opcode Command Parameters Return Parameters GAP_Authenticate 0xFE0B connHandle, secReq.ioCaps, secReq.oobAvailable, secReq.oob, secReq.authReq, secReq.maxEncKeySize, secReq.keyDist, Status pairReq.Enable, pairReq.ioCaps, pairReq.oobDataFlag, pairReq.authReq, pairReq.maxEncKeySize, pairReq.keyDist Description: Send this command to initiate the pairing process (if Central device), wait for the pairing process (if Peripheral device), or accept a pairing request (if Peripheral device). Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle secReq.ioCaps: (1 octet) Value Parameter Description 0 Display Only 1 Display – Yes or No 2 Keyboard Only Page 92 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 3 No Input and No Output 4 Keyboard and Display 5 – 0xFF reserved secReq.oobAvailable: (1 octet) Value Parameter Description 0 Out-Of-Bounds (OOB) data is NOT available 1 Out-Of-Bounds (OOB) data is available secReq.oob: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” Out-Of-Bounds data - Initial TK value for the pairing process. secReq.authReq: Bit Mask (1 octet) Bit Parameter Description 0 Bonding – exchange and save key information 1 Reserved 2 Man-In-The-Middle protection 3 LE Secure Connection pairing 4–7 Reserved secReq.maxEncKeySize: (1 octet) Range Parameter Description 7 – 16 Maximum encryption key size to support secReq.keyDist: Bit Mask (1 octet) Bit Parameter Description 0 Slave Encryption Key 1 Slave Identification Key 2 Slave Signing Key 3 Derive Slave Link Key from Slave LTK 4 Master Encryption Key Page 93 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Bit Parameter Description 5 Master Identification Key 6 Master Signing Key 7 Derive Master Link Key from Master LTK pairReq.Enable: (1 octet) Value Parameter Description 0 Pairing Request hasn’t been received. 1 Pairing Request has already been received. Peripheral Role only. The following fields should be exact same values received in the Pairing Request. pairReq.ioCaps: (1 octet) Value Parameter Description 0 Display Only 1 Display – Yes or No 2 Keyboard Only 3 No Input and No Output 4 Keyboard and Display 5 – 0xFF reserved pairReq.oobDataFlag: (1 octet) Value Parameter Description 0 Out-Of-Bounds (OOB) data is NOT available 1 Out-Of-Bounds (OOB) data is available pairReq.authReq: Bit Mask (1 octet) Bit Parameter Description 0 Bonding – exchange and save key information 1 Reserved 2 Man-In-The-Middle protection 3 LE Secure Connection pairing 4–7 Reserved Page 94 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide pairReq.maxEncKeySize: (1 octet) Range Parameter Description 7 – 16 Maximum encryption key size to support pairReq.keyDist: Bit Mask (1 octet) Bit Parameter Description 0 Slave Encryption Key 1 Slave Identification Key 2 Slave Signing Key 3 Derive Slave Link Key from Slave LTK 4 Master Encryption Key 5 Master Identification Key 6 Master Signing Key 7 Derive Master Link Key from Master LTK Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 Invalid Parameter 0x11 Already in this mode 0x12 Incorrect Profile Role 0x14 Invalid connection handle Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. When the pairing process is complete (either SUCCESS or Failure), a GAP Authentication Complete Event will be generated. If a passkey is needed, a GAP Passkey Needed Event will be generated. 12.11 GAP Update Link Parameter Request Command Opcode Command Parameters Return Parameters GAP_UpdateLinkParamReq 0xFE11 connectionHandle, intervalMin, intervalMax, connLatency, connTimeout Status Page 95 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: Send this command to change the Link Layer connection parameters of a connection. This command can only be used when the local device’s role is Master or Slave. Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle intervalMin: (2 octets) Range 6 - 3200 Minimum value for the connection event interval. This shall be less than or equal to intervalMax. Range: 0x0006 to 0x0C80 Time = intervalMin * 1.25 msec Time Range: 7.5 msec to 4 seconds. intervalMax: (2 octets) Range Parameter Description 6 - 3200 Maximum value for the connection event interval. This shall be greater than or equal to intervalMin. Range: 0x0006 to 0x0C80 Time = intervalMax * 1.25 msec Time Range: 7.5 msec to 4 seconds. connLatency: (2 octets) Range Parameter Description 0 - 499 Slave latency for the connection in number of connection events. Range: 0x0000 to 0x01F3 connTimeout: (2 octets) Range Parameter Description 10 - 3200 Supervision timeout for the LE Link. Range: 0x000A to 0x0C80 Time = connTimeout * 10 msec Page 96 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Range Parameter Description Time Range: 100 msec to 32 seconds Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x12 bleIncorrectMode 0x14 bleNotConnected Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. When the connection parameters have been applied by the Controller, the GAP Link Parameter Update Event will be generated. 12.12 GAP Passkey Update Command Opcode Command Parameters Return Parameters GAP_PasskeyUpdate 0xFE0C connHandle, passkey Status Description: Send this command when the GAP Passkey Needed Event is received. passkey needed during the Pairing Process. This command sends a Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle to issue the passkey passkey: (6 octets) Value Parameter Description “…” 6 character ASCII string of numbers (ex. “019655” ) Page 97 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x03 Passkey is NULL, or isn’t formatted properly 0x12 Link not found Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.13 GAP Slave Security Request Command Opcode Command Parameters Return Parameters GAP_SlaveSecurityRequest 0xFE0D connHandle, authReq Status Description: Send this command, Peripheral Role only, to initiate security from a slave device. This message is also sent, by the Peripheral, to upgrade security (Pairing) to “Authenticated”, make sure to ask for Man-InThe-Middle (MITM) protection in the “authReq” field. Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle authReq: Bit Mask (1 octet) Bit Parameter Description 0 Bonding – exchange and save key information 1 Reserved 2 Man-In-The-Middle protection 3 LE Secure Connection pairing 4–7 Reserved Return Parameters: Status: (1 octet) Page 98 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0x00 SUCCESS 0x11 wrong GAP role, must be a Peripheral Role 0x14 Link not found Event(s) Generated: When this command is received, the host will send the GAP HCI Ext Command Status Event with the Status parameter. 12.14 GAP Signable Command Opcode Command Parameters Return Parameters GAP_Signable 0xFE0E connHandle, authenticated, CSRK, signCounter Status Description: Send this command for a connected and bound device to enable signed data. Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle authenticated: (1 octet) Value Parameter Description 0 CSRK is not authenticated 1 CSRK is authenticated CSRK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” CSRK of connected device. signCounter: (4 octets) Page 99 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Range Parameter Description 0x00000000 – 0xFFFFFFFF 32 bit Signature Counter. The connected device’s last saved sign counter. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x12 wrong GAP role, must be a Peripheral Role 0x14 Link not found Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.15 GAP Bond Command Opcode Command Parameters Return Parameters GAP_Bond 0xFE0F connHandle, authenticated, LTK, DIV, rand, LTKsize Status Description: Send this command for a connected and bound device to load the encryption key. Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle authenticated: (1 octet) Value Parameter Description 0 LTK is not authenticated 1 LTK is authenticated LTK: (16 octets) Page 100 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Long Term Key (LTK). DIV: (2 octets) Range Parameter Description 0 – 0xFFFF The DIV used with this LTK. rand: (8 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX” The 8 byte random number generated for this LTK. LTKsize: (1 octet) Range Parameter Description 7 – 16 Encryption key size Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x12 wrong GAP role, must be a Peripheral Role 0x14 Link not found Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. When both connected devices have setup encryption, the GAP Bond Complete Event is generated. 12.16 GAP Terminate Auth Command Opcode Command Parameters Return Parameters GAP_TerminateAuth 0xFE10 connHandle, reason Status Page 101 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: Send this command to terminate a pairing process. Command Parameters: connHandle: (2 octets) Value Parameter Description 0 – 0xFFFD Connection handle reason: (1 octet) Value Parameter Description 0xXX Pairing Fail reason code Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0xXX Error code Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. When the existing pairing had ended, the GAP Authentication Complete Event with be generated. 12.17 GAP Set Parameter Command Opcode Command Parameters Return Parameters GAP_SetParam 0xFE30 paramID, paramValue Status Description: Send this command to write a GAP Parameter. Command Parameters: paramID: (1 octet) Value Parameter Description 0 TGAP_GEN_DISC_ADV_MIN - Minimum time to remain advertising, when in Discoverable mode (mSec). Setting this parameter to 0 turns off the timer Page 102 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description (default). 1 TGAP_LIM_ADV_TIMEOUT - Maximum time to remain advertising, when in Limited Discoverable mode. In seconds (default 180 seconds). 2 TGAP_GEN_DISC_SCAN - Minimum time to perform scanning, when performing General Discovery proc (mSec). 3 TGAP_LIM_DISC_SCAN - Minimum time to perform scanning, when performing Limited Discovery proc (mSec). 4 TGAP_CONN_EST_ADV_TIMEOUT Advertising performing Connection Establishment proc (mSec). 5 TGAP_CONN_PARAM_TIMEOUT - Link Layer connection parameter update notification timer, connection parameter update proc (mSec). 6 TGAP_LIM_DISC_ADV_INT_MIN - Minimum advertising interval, when in limited discoverable mode (n * 0.625 mSec). 7 TGAP_LIM_DISC_ADV_INT_MAX - Maximum advertising interval, when in limited discoverable mode (n * 0.625 mSec). 8 TGAP_GEN_DISC_ADV_INT_MIN - Minimum advertising interval, when in General discoverable mode (n * 0.625 mSec). 9 TGAP_GEN_DISC_ADV_INT_MAX - Maximum advertising interval, when in General discoverable mode (n * 0.625 mSec). 10 TGAP_CONN_ADV_INT_MIN - Minimum advertising interval, when in Connectable mode (n * 0.625 mSec). 11 TGAP_CONN_ADV_INT_MAX - Maximum advertising interval, when in Connectable mode (n * 0.625 mSec). 12 TGAP_CONN_SCAN_INT - Scan interval used during Link Layer Initiating state, when in Connectable mode (n * 0.625 mSec). 13 TGAP_CONN_SCAN_WIND - Scan window used during Link Layer Initiating state, when in Connectable mode (n * 0.625 mSec). 14 TGAP_CONN_HIGH_SCAN_INT - Scan interval used during Link Layer Initiating state, when in Connectable mode, high duty scan cycle scan paramaters (n * 0.625 mSec). 15 TGAP_CONN_HIGH_SCAN_WIND - Scan window used during Link Layer Initiating state, when in Connectable mode, high duty scan cycle scan paramaters (n * 0.625 mSec). 16 TGAP_GEN_DISC_SCAN_INT - Scan interval used during Link Layer Scanning state, when in General Discovery proc (n * 0.625 mSec). 17 TGAP_GEN_DISC_SCAN_WIND - Scan window used during Link Layer Scanning state, when in General Discovery proc (n * 0.625 mSec). 18 TGAP_LIM_DISC_SCAN_INT - Scan interval used during Link Layer Scanning state, when in Limited Discovery proc (n * 0.625 mSec). 19 TGAP_LIM_DISC_SCAN_WIND - Scan window used during Link Layer Scanning state, when in Limited Discovery proc (n * 0.625 mSec). 20 TGAP_CONN_EST_ADV - Advertising interval, when using Connection timeout, when Page 103 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description Establishment proc (n * 0.625 mSec). Obsolete - Do not use. 21 TGAP_CONN_EST_INT_MIN - Minimum Link Layer connection interval, when using Connection Establishment proc (n * 1.25 mSec). 22 TGAP_CONN_EST_INT_MAX - Maximum Link Layer connection interval, when using Connection Establishment proc (n * 1.25 mSec). 23 TGAP_CONN_EST_SCAN_INT - Scan interval used during Link Layer Initiating state, when using Connection Establishment proc (n * 0.625 mSec). 24 TGAP_CONN_EST_SCAN_WIND - Scan window used during Link Layer Initiating state, when using Connection Establishment proc (n * 0.625 mSec). 25 TGAP_CONN_EST_SUPERV_TIMEOUT - Link Layer connection supervision timeout, when using Connection Establishment proc (n * 10 mSec). 26 TGAP_CONN_EST_LATENCY - Link Layer connection slave latency, when using Connection Establishment proc (in number of connection events) 27 TGAP_CONN_EST_MIN_CE_LEN - Local informational parameter about min len of connection needed, when using Connection Establishment proc (n * 0.625 mSec). 28 TGAP_CONN_EST_MAX_CE_LEN - Local informational parameter about max len of connection needed, when using Connection Establishment proc (n * 0.625 mSec). 29 TGAP_PRIVATE_ADDR_INT - Minimum Time Interval between private (resolvable) address changes. In minutes (default 15 minutes). 30 TGAP_CONN_PAUSE_CENTRAL – Central idle timer. In seconds (default 1 second). 31 TGAP_CONN_PAUSE_PERIPHERAL – Minimum time upon connection establishment before the peripheral starts a connection update procedure. In seconds (default 5 seconds). 32 TGAP_SM_TIMEOUT - SM Message Timeout (milliseconds). Default 30 seconds. 33 TGAP_SM_MIN_KEY_LEN - SM Minimum Key Length supported. Default 7. 34 TGAP_SM_MAX_KEY_LEN - SM Maximum Key Length supported. Default 16. 35 TGAP_FILTER_ADV_REPORTS - Filter duplicate advertising reports. Default TRUE. 36 TGAP_SCAN_RSP_RSSI_MIN - Minimum RSSI responses to be reported to the app. Default -127. 37 TGAP_REJECT_CONN_PARAMS- Whether or not to reject Connection Parameter Update Request received on Central device. Default FALSE. required for scan Page 104 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide The following parameters are use for testing only (DO NOT USE): Value Parameter Description 38 TGAP_GAP_TESTCODE - GAP Test Modes: 0 – Test Mode Off 1 – No Response 39 TGAP_SM_TESTCODE - SM Test Modes: 0 – Test Mode Off 1 – No Response 2 – Send Bad Confirm 3 – Bad Confirm Verify 4 – Send SMP Confirm Message 100 TGAP_GATT_TESTCODE - GATT Test Modes: 0 – Test Mode Off 1 – Ignore incoming request 2 – Forward Prepare Write Request right away 3 – Use Max ATT MTU size with Exchange MTU Response 4 – Corrupt incoming Prepare Write Request data 101 TGAP_ATT_TESTCODE - ATT Test Modes: 0 – Test Mode Off 1 – Do Not authenticate incoming signature 102 TGAP_GGS_TESTCODE - GGS Test Modes: 0 – Test Mode Off 1 – Make Device Name attribute writable 2 – Make Appearance attribute writable 3 – Make Peripheral Privacy Flag attribute writable with authentication 103 TGAP_L2CAP_TESTCODE – L2CAP Test Modes: 0 – Test Mode Off 1 – Reserved 2 – Refuse connection – LE_PSM not supported 3 – Reserved 4 – Refuse connection – no resources available 5 – Refuse connection – insufficient authentication 6 – Refuse connection – insufficient authorization 7 – Refuse connection – insufficient encryption key size 8 – Refuse connection – insufficient encryption 9 – Allow out of range credits to be sent (0 or exceeding 65535) 10 – Send SDU larger than SDU length specified in first LE-frame of SDU 11 – Send LE-frame when local device has a credit count of zero paramValue: (2 octets) Value Parameter Description 0xXXXX Depends on the parameter Return Parameters: Page 105 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 Invalid paramID Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.18 GAP Get Parameter Command Opcode Command Parameters Return Parameters GAP_GetParam 0xFE31 paramID, Status, paramValue Description: Send this command to read a GAP Parameter. Command Parameters: paramID: (1 octet) Value Parameter Description 0xXX See paramID list in GAP Set Parameter Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 Invalid paramID paramValue: (2 octets) Value Parameter Description 0xXXXX Depends on the paramID passed in. See paramID descriptions in GAP Set Parameter for size and values. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status and paramValue parameters. Page 106 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 12.19 GAP Resolve Private Address Command Opcode Command Parameters Return Parameters GAP_ResolvePrivateAddr 0xFE32 IRK, addr Status Description: Send this command to resolve a Private Resolvable Address. Command Parameters: IRK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” IRK to resolve addr with addr: (6 octet) Range Parameter Description “XX:XX:XX:XX:XX:XX” Private resolvable address to resolve (with IRK). Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS – addr resolves 0x01 FAILURE – addr doesn’t resolve Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.20 GAP Set Advertisement Token Command Opcode Command Parameters Return Parameters GAP_SetAdvToken 0xFE33 adType, advDataLen, advData Status Page 107 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: Send this command to add an Advertisement Data Token to the advertisement data field of an advertisement packet. Command Parameters: adType: (1 octet) Value Parameter Description 0x01 Flags: Discovery Mode 0x02 Service: More 16-bit UUIDs available 0x03 Service: Complete list of 16-bit UUIDs 0x04 Service: More 32-bit UUIDs available 0x05 Service: Complete list of 32-bit UUIDs 0x06 Service: More 128-bit UUIDs available 0x07 Service: Complete list of 128-bit UUIDs 0x08 Shortened local name 0x09 Complete local name 0x0A TX Power Level: 0xXX: -127 to +127 dBm 0x0D Simple Pairing OOB Tag: Class of device (3 octets) 0x0E Simple Pairing OOB Tag: Simple Pairing Hash C (16 octets) 0x0F Simple Pairing OOB Tag: Simple Pairing Randomizer R (16 octets) 0x10 Security Manager TK Value 0x11 Secutiry Manager OOB Flags 0x12 Min and Max values of the connection interval (2 octets Min, 2 octets Max) (0xFFFF indicates no conn interval min or max) 0x13 Signed Data field 0x14 Service Solicitation: list of 16-bit Service UUIDs 0x15 Service Solicitation: list of 128-bit Service UUIDs 0x16 Service Data 0xFF Manufacturer Specific Data: first 2 octets contain the Company Identifier Code followed by the additional manufacturer specific data advDataLen: (1 octet) Page 108 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0xXX Length (in octets) of advData advData: (advDataLen octets) Value Parameter Description “XX:XX…XX” Advertisement token data (over-the-air format). Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 Invalid Advertisement Type 0x0B Token takes up too much space and doesn’t fit into Advertisement data and Scan response data. 0x12 Invalid GAP Profile Role 0x18 Advertisement Type already exists Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.21 GAP Remove Advertisement Token Command Opcode Command Parameters Return Parameters GAP_RemoveAdvToken 0xFE34 adType Status Description: Send this command to remove an Advertisement Data Token from the advertisement data field of an advertisement packet. Command Parameters: adType: (1 octet) Value Parameter Description 0x01 Flags: Discovery Mode Page 109 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x02 Service: More 16-bit UUIDs available 0x03 Service: Complete list of 16-bit UUIDs 0x04 Service: More 32-bit UUIDs available 0x05 Service: Complete list of 32-bit UUIDs 0x06 Service: More 128-bit UUIDs available 0x07 Service: Complete list of 128-bit UUIDs 0x08 Shortened local name 0x09 Complete local name 0x0A TX Power Level: 0xXX: -127 to +127 dBm 0x0D Simple Pairing OOB Tag: Class of device (3 octets) 0x0E Simple Pairing OOB Tag: Simple Pairing Hash C (16 octets) 0x0F Simple Pairing OOB Tag: Simple Pairing Randomizer R (16 octets) 0x10 Security Manager TK Value 0x11 Secutiry Manager OOB Flags 0x12 Min and Max values of the connection interval (2 octets Min, 2 octets Max) (0xFFFF indicates no conn interval min or max) 0x13 Signed Data field 0x14 Service Solicitation: list of 16-bit Service UUIDs 0x15 Service Solicitation: list of 128-bit Service UUIDs 0x16 Service Data 0xFF Manufacturer Specific Data: first 2 octets contain the Company Identifier Code followed by the additional manufacturer specific data Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 adType not found. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. Page 110 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 12.22 GAP Update Advertisement Tokens Command Opcode GAP_UpdateAdvToken 0xFE35 Command Parameters Return Parameters Status Description: After adding an removing advertisement tokens, they must be updated to actual advertisements by sending this command. Command Parameters: none Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.22.1 GAP Bond Set Parameter Command Opcode Command Parameters Return Parameters GAP_BondSetParam 0xFE36 paramID, paramDataLen, paramData Status Description: Send this command to set a GAP Bond parameter. Command Parameters: paramID: (2 octets) Value Parameter Description 0x0400 Pairing Mode - Read/Write. Size is uint8. Values: Page 111 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x00 – Pairing Not allowed 0x01 – Wait for Request (default) 0x02 – Don’t wait, initiate a Slave Requested Security command (not available yet). 0x0401 Pairing Mode Initiate wait timeout. This is the time it will wait for a Pairing Request before sending the Slave Initiate Request. Read/Write. Size is uint16. Default is 1000(in milliseconds). 0x0402 Man-In-The-Middle (MITM) basically turns on Passkey protection in the pairing algorithm. Read/Write. Size is uint8. Values: 0x00 – Disabled (default). 0x01 – Enabled. 0x0403 I/O capabilities. Read/Write. Size is uint8. Values: 0x00 – Display Only Device (default) 0x01 – Display – Yes an No capable 0x02 – Keyboard only 0x03 – No Input, No Output 0x04 – Keyboard and Display 0x0404 OOB data available for pairing algorithm. Read/Write. Size is uint8. Values: 0x00 – Disabled (default). 0x01 – Enabled. 0x0405 OOB Data. Read/Write. Size uint8[16]. Default is all 0's. 0x0406 Request Bonding during the pairing process if enabled. Read/Write. Size is uint8. Values: 0x00 – Disabled (default). 0x01 – Enabled. 0x0407 The key distribution list for bonding. Size is uint8. Bit Values: Bit 0 – Slave LTK and key information (default) Bit 1 – Slave IRK and ID information (default) Bit 2 – Slave CSRK (default) Bit 3 - Derive Slave Link Key from Slave LTK Bit 4 – Master LTK and key information (default) Bit 5 – Master IRK and ID information (default). Bit 6 – Master CSRK (default) Bit 7 - Derive Master Link Key from Master LTK 0x0408 The default passcode for MITM protection. Size is uint32. Range is 0 - 999,999. Default is 0. 0x0409 Erase all of the bonded devices. Write Only - command. No Size. Page 112 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x040A Test mode to automatically send a Pairing Fail when a Pairing Request is received. Read/Write. size is uint8. Default is 0 (disabled). Set to 1 to enable. 0x040B Test mode Pairing Fail reason when auto failing. Read/Write. size is uint8. Default is 0x05 (SMP_PAIRING_FAILED_NOT_SUPPORTED). 0x040C Key Size used in pairing. Read/Write. Size is uint8. Default is 16. 0x040D Clears the White List adds to it each unique address stored by bonds in NV. Read/Write. Size is uint8. Default is FALSE. 0x040E Gets the total number of bonds stored in NV. Read Only. Size is uint8. Default is 0 (no bonds). 0x040F Possible actions Central may take upon an unsuccessful bonding. Write Only. Size is uint8. Default is 1 (initiate pairing). 0x0410 Erase a single bonded device. Write only. First byte is the peer device’s address type and the following 6 bytes are the peer device’s address. paramDataLen: (1 octet) Value Parameter Description 0xXX Length (in octets) of paramData paramData: (paramDataLen octets) Value Parameter Description “XX:XX…XX” Parameter data – depends on paramID. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 Invalid paramID 0x18 Invalid paramDataLen Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 12.22.2 GAP Bond Get Parameter Command Opcode Command Parameters Return Parameters Page 113 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Command Opcode Command Parameters Return Parameters GAP_BondGetParam 0xFE37 paramID Status, paramDataLen, paramData Description: Send this command to read a GAP Bond parameter. Command Parameters: paramID: (2 octets) Value Parameter Description 0xXX See paramID in GAP Bond Set Parameter Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 Invalid paramID 0x18 Invalid paramDataLen paramDataLen: (1 octet) Value Parameter Description 0xXX Length (in octets) of paramData paramData: (paramDataLen octets) Value Parameter Description “XX:XX…XX” Depends on the paramID. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status, paramDataLen, paramData parameters. Page 114 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 13. GAP Vendor Specific Events 13.1 GAP Device Init Done Event Opcode Event Parameters GAP_DeviceInitDone 0x0600 Status, devAddr, dataPktLen, numDataPkts, IRK, CSRK, Description: This event is sent to indicate that the device is done initializing. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS devAddr: (6 octets) Value Parameter Description “XX:XX:XX:XX:XX:XX” The device’s public address (BD_ADDR). dataPktLen: (2 octets) Range Parameter Description 0x0000 – 0xFFFF HC_LE_Data_Packet_Length numDataPkts: (1 octet) Range Parameter Description 0x00 – 0xFF HC_Total_Num_LE_Data_Packets IRK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Identity Resolving Key (IRK). This is either a randomly generated key or the original key passed in the GAP_DeviceInit command. CSRK: (16 octets) Value Parameter Description Page 115 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Connection Signature Resolving Key (CSRK). This is either a randomly generated key or the original key passed in the GAP_DeviceInit command. 13.2 GAP Device Discovery Event Opcode Event Parameters GAP_DeviceDiscovery 0x0601 Status, numDevs, array of {eventType, addrType, addr} Description: This event is sent to indicate that the scan is complete. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS numDevs: (1 octet) Range Parameter Description 0 – 0xFF The number of advertising devices detected during the scan. The number reflects the type of filter used during the scan. eventType: (1 octet) Value Parameter Description 0 Connectable undirected advertisement 1 Connectable directed advertisement 2 Discoverable undirected advertisement 3 Non-connectable undirected advertisement 4 Scan Response addrType: (1 octet) Value Parameter Description Page 116 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE addr: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” Address of the device scanned. 13.3 GAP Advert Data Update Done Event Opcode Event Parameters GAP_AdvertDataUpdateDone 0x0602 Status , adType Description: This event is sent when the device sets the advertising data because of the GAP Update Advertising Data Command. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS adType: (1 octet) Value Parameter Description 0 SCAN_RSP data 1 Advertisement data 13.4 GAP Make Discoverable Done Event Opcode Event Parameters GAP_MakeDiscoverableDone 0x0603 Status Page 117 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: This event is sent when the device starts advertising. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS interval: (2 octets) Range Parameter Description 0xXXXX Actual advertising interval selected by the Controller 13.5 GAP End Discoverable Done Event Opcode Event Parameters GAP_EndDiscoverableDone 0x0604 Status Description: This event is sent when the device ends advertising. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 13.6 GAP Link Established Event Opcode Event Parameters GAP_LinkEstablished 0x0605 Status, devAddrType, devAddr, connHandle, connRole, connInterval, connLatency, connTimeout, clockAccuracy Page 118 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: This message is sent when a connection is established with another device. On a Central device, this message is a result for a GAP Establish Link Request. On a Peripheral device, this message is received when a central device initiated a connection. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS devAddrType: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE devAddr: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” Address of the connected device connHandle: (2 octets) Range Parameter Description 0 – 0xFFFD Handle of the connection. This will be used to reference the connection in other “connection based” commands. connRole: Bit Mask (1 octet) Value Parameter Description 0x04 GAP_PROFILE_PERIPHERAL 0x08 GAP_PROFILE_CENTRAL connInterval: (2 octets) Value Parameter Description N = 0xXXXX Connection interval used on this connection. Range: 0x0006 to 0x0C80 Time = N * 1.25 msec Page 119 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description Time Range: 7.5 msec to 4 seconds connLatency: (2 octets) Value Parameter Description N = 0xXXXX Connection latency used on this connection. Range: 0x0000 to 0x01F3 connTimeout: (2 octets) Value Parameter Description N = 0xXXXX Connection supervision timeout. Range: 0x000A to 0x0C80 Time = N * 10 msec Time Range: 100 msec to 32 seconds clockAccuracy: (1 octet) Value Parameter Description 0 500 ppm 1 250 ppm 2 150 ppm 3 100 ppm 4 75 ppm 5 50 ppm 6 30 ppm 7 20 ppm 8 – 0xFF reserved 13.7 GAP Link Terminated Event Opcode Event Parameters GAP_LinkTerminated 0x0606 Status, connHandle, reason Description: This message is sent whenever a link is terminated. Page 120 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS connHandle: (2 octets) Value Parameter Description XX Connection Handle of terminated link reason: (1 octet) Value Parameter Description 0x08 Supervisor Timeout 0x13 Peer Requested 0x16 Host Requested 0x22 Control Packet Timeout 0x28 Control Packet Instant Passed 0x3B LSTO Violation 0x3D MIC Failure 13.8 GAP Link Parmeter Update Event Opcode Event Parameters GAP_LinkParamUpdate 0x0607 Status, connHandle, connInterval, connLatency, connTimeout Description: This message is sent whenever connection parameter update is completed. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS connHandle: (2 octets) Page 121 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description XX Connection Handle of link connInterval: (2 octets) Value Parameter Description N = 0xXXXX Connection interval used on this connection. Range: 0x0006 to 0x0C80 Time = N * 1.25 msec Time Range: 7.5 msec to 4 seconds connLatency: (2 octets) Value Parameter Description N = 0xXXXX Connection latency used on this connection. Range: 0x0000 to 0x01F3 connTimeout: (2 octets) Value Parameter Description N = 0xXXXX Connection supervision timeout. Range: 0x000A to 0x0C80 Time = N * 10 msec Time Range: 100 msec to 32 seconds 13.9 GAP Random Address Changed Event Opcode Event Parameters GAP_RandomAddrChanged 0x0608 Status, addrType, newRandomAddr Description: This message is sent whenever the device’s Private Resolvable Address automatically changes. Event Parameters: Status: (1 octet) Value Parameter Description Page 122 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0x00 SUCCESS addrType: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE newRandomAddr: (6 octets) Value Parameter Description “XX:XX:XX:XX:XX:XX” New Private Resolvable Address was generated. 13.10 GAP Signature Updated Event Opcode Event Parameters GAP_SignatureUpdated 0x0609 Status, addrType, devAddr, signCounter Description: This message is sent whenever sign counter is updated (incremented). This message will be generated when a new sign counter is received from a connected device or when this device increments its own sign counter. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS addrType: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE Page 123 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 3 ADDRTYPE_PRIVATE_RESOLVE devAddr: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” The device address of the sign counter that changed. It may be this device or a connected device. signCounter: (6 octets) Range Parameter Description 0 – 0xFFFFFFFF The new sign counter value for the referenced device. 13.11 GAP Authentication Complete Event Opcode Event Parameters GAP_AuthenticationComplete 0x060A Status, connHandle, authState, secInfo, secInfo.LTKsize, secInfo.LTK, secInfo.DIV, secInfo.rand, devSecInfo, devSecInfo.LTKsize, devSecInfo.LTK, devSecInfo.DIV, devSecInfo.rand, identityInfo, identityInfo.IRK, identityInfo.BD_ADDR, signingInfo, signingInfo.CSRK, signingInfo.signCounter Description: This event is generated whenever the pairing process is completed (pass or fail). Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 – 0xFF Pairing failures connHandle: (2 octets) Page 124 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description XX Connection Handle of link authState: Bit Mask (1 octet) Bit Parameter Description 0 Bonding – exchange and save key information 1 Reserved 2 Man-In-The-Middle protection 3 LE Secure Connection pairing 4–7 Reserved secInfo: (1 octet) Value Parameter Description 0x00 The following “secInfo” parameters are NOT enabled in this event. 0x01 The following “secInfo” parameters are enabled in this event. The following security information is for the device itself: secInfo.LTKsize: (1 octet) Range Parameter Description 7 – 16 Encryption key size secInfo.LTK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Long Term Key (LTK). secInfo.DIV: (2 octets) Range Parameter Description 0 – 0xFFFF The DIV used with this LTK. secInfo.rand: (8 octets) Page 125 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX” The 8 byte random number generated for this LTK. devSecInfo: (1 octet) Value Parameter Description 0x00 The following “devSecInfo” parameters are NOT enabled in this event. 0x01 The following “devSecInfo” parameters are enabled in this event. The following security information is for the connected peer device: devSecInfo.LTKsize: (1 octet) Range Parameter Description 7 – 16 Encryption key size devSecInfo.LTK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Long Term Key (LTK). devSecInfo.DIV: (2 octets) Range Parameter Description 0 – 0xFFFF The DIV used with this LTK. devSecInfo.rand: (8 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX” The 8 byte random number generated for this LTK. identityInfo: (1 octet) Value Parameter Description 0x00 The following “identityInfo” parameters are NOT enabled in this event. 0x01 The following “identityInfo” parameters are enabled in this Page 126 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description event. identityInfo.IRK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Identity Root Key (IRK). Used to resolve Private Resolvable Addresses. identityInfo.BD_ADDR: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” The connected device’s Public Address. signingInfo: (1 octet) Value Parameter Description 0x00 The following “signingInfo” parameters are NOT enabled in this event. 0x01 The following “signingInfo” parameters are enabled in this event. signingInfo.IRK: (16 octets) Value Parameter Description “XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX: XX:XX:XX:XX” 16 byte Connected Signature Resolving Key (CSRK). signingInfo.signCounter: (2 octets) Range Parameter Description 0 – 0xFFFF The connected device’s current sign counter 13.12 GAP Passkey Needed Event Opcode Event Parameters GAP_PasskeyNeeded 0x060B Status, devAddr, connHandle, uiInputs, uiOutputs Page 127 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Description: This event is generated during the pairing process if a passkey is needed. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS devAddr: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” Address of the pairing device. connHandle: (2 octets) Value Parameter Description XX Connection Handle of link uiInput: (1 octet) Value Parameter Description 0x00 Don’t ask user to input a passcode 0x01 Ask user to input a passcode uiOuput: (1 octet) Value Parameter Description 0x00 Don’t display passcode 0x01 Display a passcode 13.13 GAP Slave Requested Security Event Opcode Event Parameters GAP_SlaveRequestedSecurity 0x060C Status, connHandle, devAddr, authReq Description: This message is generated when the master device receives an SM Slave Request from the connected slave device. Page 128 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS connHandle: (2 octets) Value Parameter Description XX Connection Handle of link devAddr: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” The connected device’s address. authReq: Bit Mask (1 octet) Bit Parameter Description 0 Bonding – exchange and save key information 1 Reserved 2 Man-In-The-Middle protection 3 LE Secure Connection pairing 4–7 Reserved 13.14 GAP Device Information Event Opcode Event Parameters GAP_DeviceInformation 0x060D Status, eventTypes, addrType, addr, rssi, dataLen, dataField Description: This message is sent during a scan and represents another device’s advertisement or SCAN_RSP packet. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS Page 129 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide eventType: (1 octet) Value Parameter Description 0 Connectable undirected advertisement 1 Connectable directed advertisement 2 Discoverable undirected advertisement 3 Non-connectable undirected advertisement 4 Scan Response addrType: (1 octet) Value Parameter Description 0 ADDRTYPE_PUBLIC 1 ADDRTYPE_STATIC 2 ADDRTYPE_PRIVATE_NONRESOLVE 3 ADDRTYPE_PRIVATE_RESOLVE addr: (6 octets) Range Parameter Description “XX:XX:XX:XX:XX:XX” Address of the device scanned. rssi: (1 octet) Range Parameter Description 0x00 – 0xFF dataLen: (1 octet) Range Parameter Description 0x00 – 0xFF Number of octets in the following dataField field. dataField: (dataLen octets) Range Parameter Description “XX:XX … XX” Data field of the advertisement or SCAN_RSP packets. 13.15 GAP Bond Complete Page 130 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event Opcode Event Parameters GAP_BondComplete 0x060E Status, connHandle Description: This message is sent when a bond is complete and the connection is encrypted. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 – 0xFF error connHandle: (2 octets) Value Parameter Description XX Connection Handle of link 13.16 GAP Pairing Requested Event Opcode Event Parameters GAP_PairingRequested 0x060F Status, connHandle, ioCap, oobDataFlag, authReq, maxEncKeySize, keyDist Description: This message is sent when a bond is complete and the connection is encrypted. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 – 0xFF error connHandle: (2 octets) Value Parameter Description XX Connection Handle of link Page 131 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide ioCap: (1 octet) Value Parameter Description 0 Display Only 1 Display – Yes or No 2 Keyboard Only 3 No Input and No Output 4 Keyboard and Display 5 – 0xFF reserved oobDataFlag: (1 octet) Value Parameter Description 0 Out-Of-Bounds (OOB) data is NOT available 1 Out-Of-Bounds (OOB) data is available authReq: Bit Mask (1 octet) Bit Parameter Description 0 Bonding – exchange and save key information 1 Reserved 2 Man-In-The-Middle protection 3 LE Secure Connection pairing 4–7 Reserved maxEncKeySize: (1 octet) Range Parameter Description 7 – 16 Maximum encryption key size to support keyDist: Bit Mask (1 octet) Bit Parameter Description 0 Slave Encryption Key 1 Slave Identification Key 2 Slave Signing Key 3 Derive Slave Link Key from Slave LTK 4 Master Encryption Key 5 Master Identification Key 6 Master Signing Key Page 132 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Bit Parameter Description 7 Derive Master Link Key from Master LTK 13.17 Command Status Event Opcode Event Parameters CommandStatus 0x067F Status, opCode, dataLen, payload Description: The Command Status event is used to indicate that the command given by opCode parameter has been received and is being processed. If successful, an HCI vendor specific event that corresponds to the command will follow. Otherwise, no event will follow since the command was not started. Event Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 – 0xFF See section Host Error Codes [20] opCode: (2 octets) Value Parameter Description XX Command opcode dataLen: (1 octet) Value Parameter Description XX Length of payload payload: (dataLen octets) Value Parameter Description “XX:XX…XX” Command payload Page 133 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 14. UTIL Vendor Specific Commands 14.1 UTIL NV Read Command Command Opcode Command Parameters Return Parameters UTIL_NVRead 0xFE81 nvID, nvDataLen Status, nvData Description: Send this command to read an NV parameter. Command Parameters: nvID: (1 octet) Value Parameter Description 0x02 This device’s IRK. Size is 16 bytes. 0x03 This device’s CSRK. Size is 16 bytes. 0x04 This device’s sign counter. Size is uint32. 0x20 – 0x5F GAP Bond Manager NV Items. GAP Bond Manager NV Items: This range is taken with the following repeating ID offsets, used below: 0 – bondRecord 1 – localLTK 2 – deviceLTK 3 – deviceIRK 4 – deviceCSRK 5 – deviceSignCounter To calculate an NV item for the GAP Bond Manager: The NV definitions: NVID_GB_START (0x20) - starting GAP Bond Manager NV ID GAP_BONDINGS_MAX (default 10) - Maximum number of bonding allowed (10 is max for number of NV IDs allocated in bcomdef.h). Definitions for the formulas: KEYLEN – 16 bytes B_ADDR_LEN – 6 bytes MAX_OFFSETS = 6 B_RANDOM_NUM_SIZE = 8 Structure definitions: typedef struct { Page 134 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide uint8 LTK[KEYLEN]; uint16 div; uint8 rand[B_RANDOM_NUM_SIZE]; uint8 keySize; } gapBondLTK_t; typedef struct { uint8 publicAddr[B_ADDR_LEN]; uint8 reconnectAddr[B_ADDR_LEN]; uint16 stateFlags; } gapBondRec_t; // Master's address A single bonding entry consists of 6 components (NV items): Bond Record - defined as gapBondRec_t and uses for an NV ID offset local LTK Info - defined as gapBondLTK_t and uses localLTK for an NV ID offset device LTK Info - defined as gapBondLTK_t and uses deviceLTK for an NV ID offset device IRK - defined as "uint8 [KEYLEN]" and uses deviceIRK for an NV ID offset device CSRK - defined as "uint8 [KEYLEN]" and uses deviceCSRK for an NV ID offset device Sign Counter - defined as a uint32 and uses deviceSignCounter for an NV ID offset When the device is initialized for the first time, all (GAP_BONDINGS_MAX) NV items are created and initialized to all 0xFF's. A bonding record of all 0xFF's indicates that the bonding record is empty and free to use. Example calculation for each bonding records NV IDs, bondIdx represents the bond record (0-9): mainRecordNvID = ((bondIdx * MAX_OFFSETS) + NVID_GB_START) localLTKNvID = (((bondIdx * MAX_OFFSETS) + localLTK) + NVID_GB_START) devlLTKNvID = (((bondIdx * MAX_OFFSETS) + devlLTK) + NVID_GB_START) devIRKNvID = (((bondIdx * MAX_OFFSETS) + devIRK) + NVID_GB_START) devCSRKNvID = (((bondIdx * MAX_OFFSETS) + devCSRK) + NVID_GB_START) devSignCounterNvID = (((bondIdx * MAX_OFFSETS) + devSignCounter) + NVID_GB_START) nvDataLen: (1 octet) Value Parameter Description 0xXX Length (in octets) to read from nvID Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0xXX failure nvData: (nvDataLen octets) Value Parameter Description Page 135 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description “XX:XX…XX” NV Data – depends on the nvID passed in. Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status and nvData parameters. 14.2 UTIL NV Write Command Command Opcode Command Parameters Return Parameters UTIL_NVWrite 0xFE82 nvID, nvDataLen, nvData Status Description: Send this command to write an NV parameter. Command Parameters: nvID: (1 octet) Value Parameter Description 0xXX See the nvID description in the UTIL NV Read Command nvDataLen: (1 octet) Value Parameter Description 0xXX Length (in octets) nvData nvData: (nvDataLen octets) Value Parameter Description “XX:XX…XX” NV Data depends on the nvID Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0xXX failure Page 136 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status parameter. 14.3 UTIL Force Boot Command Command Opcode Command Parameters Return Parameters UTIL_ForceBoot 0xFE83 None Status Description: Force the boot loader to run. Command Parameters: None Return Parameters: Status: (1 octet) Value Parameter Description 0x02 INVALIDPARAMETER Event(s) Generated: When this command is received, the device resets if the boot loader is present. Otherwise, the host will send the HCI Ext Command Status Event with the Status parameter set to 0x02. 14.4 UTIL Build Revision Command Command Opcode Command Parameters Return Parameters UTIL_BuildRevision 0xFE84 None Status, Build Revision Description: This command is used to read the build revision information of the BLE stack software. Command Parameters: None Page 137 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0xXX failure Build Revision: (10 octets) Value Parameter Description “XX:XX…XX” Build Revision (10 octets): Stack version (octets 0-2): o Major (octet 0) o Minor (octet 1) o Patch (octet 2) Build version (octets 3-4) Stack Information (octet 5) - bitmask: o Bit 0: IAR used to build stack project (0: no, 1: yes) o Bit 1: CCS used to build stack project (0: no, 1: yes) o Bits 2-3: Reserved o Bit 4: IAR used to build stack library (0: no, 1: yes) o Bits 5-6: Reserved o Bit 7: ROM build (0: no, 1: yes) Control information (octets 6-7) – bitmask: o Octet 6: Bit 0: ADV_NCONN_CFG (0: not included, 1: included) Bit 1: ADV_CONN_CFG (0: not included, 1: included) Bit 2: SCAN_CFG (0: not included, 1: included) Bit 3: INIT_CFG (0: not included, 1: included) Bit 4: PING_CFG (0: not included, 1: included) Bit 5: SLV_FEAT_EXCHG_CFG (0: not included, 1: included) Bit 6: CONN_PARAM_REQ_CFG (0: not included, 1: included) Bit 7: Reserved Page 138 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description o Octet 7: Reserved Host information (octets 8-9) - bitmask: o o Octet 8: Bit 0: BROADCASTER_CFG (0: not included, 1: included) Bit 1: OBSERVER_CFG (0: not included, 1: included) Bit 2: PERIPHERAL_CFG (0: not included, 1: included) Bit 3: CENTRAL_CFG (0: not included, 1: included) Bit 4: GAP_BOND_MGR (0: not included, 1: included) Bit 5: L2CAP_CO_CHANNELS included, 1: included) Bits 6-7: Reserved (0: not Octet 9: Reserved Event(s) Generated: When this command is received, the host will send the HCI Ext Command Status Event with the Status and Build Revision parameters. Page 139 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 15. L2CAP Vendor Specific Commands All L2CAP commands have the following format: Name Size (octets) Description Opcode 2 PDU operation code connectionHandle, CID, or PSM 2 Connection Handle of link is applicable to: L2CAP_ConnParamUpdateReq L2CAP_ConnectReq L2CAP_ConnectRsp CID (Channel ID) is applicable to: L2CAP_DisconnectReq L2CAP_FlowCtrlCredit L2CAP_Data L2CAP_ChannelInfo PSM (Protocol/Service Multiplexer) is applicable to: Command PDU Variable L2CAP_RegisterPsm L2CAP_DeregisterPsm L2CAP_PsmInfo L2CAP_PsmChannels Command parameters Note: The connection handle of 0xFFFE is considered as the loopback connection. All message sent to this connection will be looped back to the local host. For the command parameters, please see the corresponding section below. LE Protocol/Service Multiplexer (PSM) values are separated into two ranges: Fixed (0x0001 – 0x007F): Values in the first range are assigned by the Bluetooth SIG and indicate protocols. Dynamic (0x0080 – 0x00FF): Values in the second rage are dynamically allocated and used in conjunction with services defined in the GATT server. 15.1 L2CAP_Data (0xFCF0) The L2CAP Data command is used to send an SDU on a Connection Oriented Channel established with the peer device. Page 140 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Command Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID SDU: (1 to L2CAP_SDU_SIZE octets) Range Parameter Description “XX:…XX” SDU to send on the channel Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x14 bleNotConnected 0x16 blePending 0x1B bleInvalidMtuSize Event(s) Generated: When this command is received, the local device will send the Command Status Event with the Status parameter. When the SDU transmission is done to the peer device, the L2CAP Send SDU Done Event (L2CAP_SendSduDone) will be generated. If the local channel runs out of credits required to send the SDU, the L2CAP Out of Credit Event (L2CAP_OutOfCredit) will be generated. 15.2 L2CAP_RegisterPsm (0xFCF1) The L2CAP Register PSM command is used to register a Protocol/Service Multiplexer (PSM) with the L2CAP layer. Command Parameters: PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM to be registered with L2CAP MTU: (2 octets) Value Parameter Description 0xXXXX Maximum SDU size that can be received by the local Page 141 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description device initialPeerCredits: (2 octets) Value Parameter Description 0xXXXX Number of LE-frames that the peer device can send peerCreditThreshold: (2 octets) Value Parameter Description 0xXXXX Low threshold for the peer credit count maxNumChannels: (1 octet) Value Parameter Description 0xXX Maximum number of Connection Oriented Channels supported by the local PSM enableSecurityVerification: (1 octet) Value Parameter Description 0x00 No application security verification is required. L2CAP should handle any incoming L2CAP Connect Request. 0x01 Security verification will be done by the application. Any incoming L2CAP Connect Request should be forwarded to the application. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x11 bleAlreadyInRequestedMode 0x15 bleNoResources 0x18 bleInvalidRange 0x1B bleInvalidMtuSize Event(s) Generated: Page 142 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide When this command is received, the local device will send the Command Status Event with the Status parameter. If the application wishes to perform its own security verification (by setting enableSecurityVerification to TRUE) for any incoming connection request then an L2CAP Connection Request (L2CAP_ConnectReq) event will be sent up to the application, which must then send an L2CAP Connection Response (L2CAP_ConnectRsp) command back. When the peer credit count reaches the peer credit threshold (specified by peerCreditThreshold), the L2CAP Peer Credit Threshold Event (L2CAP_PeerCreditThreshold) will be generated. 15.3 L2CAP_DeregisterPsm (0xFCF2) The L2CAP Deregister PSM command is sent to deregister a Protocol/Service Multiplexer (PSM) with the L2CAP layer. Command Parameters: PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM to be deregistered with L2CAP Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x12 bleIncorrectMode Event(s) Generated: When this request is received, the local device will send the Command Status Event with the Status parameter. 15.4 L2CAP_PsmInfo (0xFCF3) The L2CAP PSM Info command is used to get the current information about a given PSM registered with the L2CAP layer. Command Parameters: PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM Page 143 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER MTU: (2 octets) Value Parameter Description 0xXXXX Maximum SDU size that can be received by the local device MPS: (2 octets) Value Parameter Description 0xXXXX Maximum payload size that can be received by the local device initialPeerCredits: (2 octets) Value Parameter Description 0xXXXX Number of LE-frames that the peer device can send peerCreditThreshold: (2 octets) Value Parameter Description 0xXXXX Low threshold for the number of peer credits maxNumChannels: (1 octet) Value Parameter Description 0xXX Maximum number of Connection Oriented Channels supported by the local PSM numActiveChannels: (1 octet) Range Parameter Description 0xXX Number of active Connection Oriented Channels for the local PSM Page 144 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event(s) Generated: When this request is received, the local device will send the Command Status Event with the Status, MTU, MPS, initialPeerCredits, peerCreditThreshold, maxNumChannels, and numActiveChannels parameters. 15.5 L2CAP_PsmChannels (0xFCF4) The L2CAP PSM Channels command is used to get the list of all the active Connection Oriented Channels for a given PSM registered with the L2CAP layer. Command Parameters: PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER CID: (2 octets) Value Parameter Description “XX:XX:…XX:XX” List of Channel IDs Event(s) Generated: When this request is received, the local device will send the Command Status Event with the Status and CID parameters. The CID parameter will be repeated for each active channel. 15.6 L2CAP_ChannelInfo (0xFCF5) The L2CAP Channel Info command is used to get the current information about an active Connection Oriented Channel. Command Parameters: CID: (2 octets) Range Parameter Description Page 145 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Range Parameter Description 0x0040 – 0x007F Local Channel ID Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER State: (1 octet) Value Parameter Description 0x00 Closed - no channel is associated with this Channel ID 0x01 Open - channel is open 0x02 Pending - waiting for a Connection Response from the peer device 0x03 Pending - waiting for a Disconnection Response from the peer device 0x04 Pending - waiting for a Connection Parameter Update Response from the peer device 0x05 Pending - waiting for a Info Response from the peer device 0x06 Pending - waiting for Security Verification from the local PSM PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM that the channel belongs to CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID MTU: (2 octets) Value Parameter Description 0xXXXX Maximum SDU size that can be received by the local device on this channel Page 146 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide MPS: (2 octets) Value Parameter Description 0xXXXX Maximum payload size that can be received by the local on this channel credits: (2 octets) Value Parameter Description 0xXXXX Number of LE-frames that local device can send peerCID: (2 octets) Range Parameter Description 0x0040 – 0x007F Remote Channel ID peerMTU: (2 octets) Value Parameter Description 0xXXXX Maximum SDU size that can be received by the peer device peerMPS: (2 octets) Value Parameter Description 0xXXXX Maximum payload size that can be received by peer device peerCredits: (2 octets) Value Parameter Description 0xXXXX Number of LE-frames that the peer device can send peerCreditThreshold: (2 octets) Range Parameter Description 0xXXXX Low threshold for the peer credit count Event(s) Generated: When this request is received, the local device will send the Command Status Event with the Status, state, PSM, CID, MTU, MPS, credits, peerCID, peerMTU, peerMPS, peerCredits, and peerCreditThreshold parameters. Page 147 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 15.7 L2CAP_ConnectReq (0xFC94) The L2CAP Connection Request command is used to create and configure a Connection Oriented Channel between the local and the peer device. Command Parameters: PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM to initiate a new connection from peerPSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Peer PSM to initiate a new connection to Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x12 bleIncorrectMode 0x13 bleMemAllocError 0x14 bleNotConnected 0x15 bleNoResources Event(s) Generated: When this command is received, the local device will send the Command Status Event with the Status parameter after sending an LE Credit Based Connection Request to the peer device. When a new channel has been established, the L2CAP Channel Established Event (L2CAP_ChannelEstablished) will be generated. 15.8 L2CAP_ConnectRsp (0xFC95) When a device receives an LE Credit Based Connection Request, it must send an LE Credit Based Connection Response back, which is done automatically by the L2CAP layer. However, if the application wishes to perform its own security verification (configurable at PSM registration), then a Connection Request (L2CAP_ConnectReq) event will be sent up to the application which must then send a Page 148 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Connection Response (L2CAP_ConnectRsp) command back indicating the outcome of the connection request. Command Parameters: id: (1 octet) Range Parameter Description 0x01 – 0xFF Identifier to match responses with requests (i.e., id received with L2CAP Connect Request event) result: (2 octets) Value Parameter Description 0x0000 Connection successful 0x0001 Reserved 0x0002 Connection refused – LE PSM not supported 0x0003 Reserved 0x0004 Connection refused – no resources available 0x0005 Connection refused – insufficient authentication 0x0006 Connection refused – insufficient authorization 0x0007 Connection refused – insufficient encryption key size 0x0008 Connection refused – insufficient encryption 0x0009 – 0xFFFF Reserved Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x13 bleMemAllocError 0x14 bleNotConnected Event(s) Generated: When this request is received, the local device will send the Command Status Event with the Status parameter after sending an LE Credit Based Connection Response back to the peer device. Page 149 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 15.9 L2CAP_DisconnectReq (0xFC86) The L2CAP Disconnection Request is sent to terminate a Connection Oriented Channel established between the local and the peer device. Command Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel to disconnect Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x13 bleMemAllocError 0x14 bleNotConnected 0x15 bleNoResources Event(s) Generated: When this command is received, the local device will send the Command Status Event with the Status parameter after forwarding the request to the peer device. When the channel is terminated, the L2CAP Channel Terminated Event (L2CAP_ChannelTerminated) will be generated. 15.10 L2CAP_FlowCtrlCredit (0xFC96) The LE Flow Control Credit commands are sent when the local device is capable of receiving additional LE-frames on an established L2CAP channel. Command Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID peerCredits: (2 octets) Range Parameter Description Page 150 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Range Parameter Description 0x0001 – 0xFFFF Number of LE-frames that can be sent to the local device Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x13 bleMemAllocError 0x14 bleNotConnected 0x18 bleInvalidRange Event(s) Generated: When this request is received, the local device will send the Command Status Event with the Status parameter after forwarding the request to the peer device. When the peer credit count reaches a specified low threshold (configurable at PSM registration), the L2CAP Peer Credit Threshold Event (L2CAP_PeerCreditThreshold) will be generated. 15.11 L2CAP_ConnParamUpdateReq (0xFC92) The Connection Parameter Update Request is sent from the LE slave device to the LE master device. This request allows the LE slave Host to request a set of new connection parameters. Command Parameters: intervalMin: (2 octets) Range 6 - 3200 Defines minimum value for the connection event interval in the following manner: connIntervalMin = Interval Min * 1.25 ms. Interval Min range: 6 to 3200 frames where 1 frame is 1.25 ms and equivalent to 2 BR/EDR slots. Values outside the range are reserved. Interval Min shall be less than or equal to Interval Max. intervalMax: (2 octets) Range Parameter Description 6 - 3200 Defines maximum value for the connection event interval Page 151 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Range Parameter Description in the following manner: connIntervalMax = Interval Max * 1.25 ms. Interval Max range: 6 to 3200 frames. Values outside the range are reserved. Interval Max shall be equal to or greater than the Interval Min. slaveLatency: (2 octets) Range Parameter Description 0 - 500 Defines the slave latency parameter (as number of LL connection events) in the following manner: connSlaveLatency = Slave Latency. The Slave Latency field shall have a value in the range of 0 to ((connSupervisionTimeout / connIntervalMax) - 1). The Slave Latency field shall be less than 500. timeoutMultiplier: (2 octets) Range Parameter Description 10 - 3200 Defines connection timeout parameter in the following manner: connSupervisionTimeout = Timeout Multiplier * 10 ms The Timeout Multiplier field shall have a value in the range of 10 to 3200. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x13 bleMemAllocError 0x14 bleNotConnected 0x15 bleNoResources Event(s) Generated: When this request is received, the LE slave host will send the Command Status Event with the Status parameter after forwarding the request to the LE master host. The LE master host will send the Connection Parameter Update Response (L2CAP_ConnParamUpdateRsp) event back. Page 152 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide If the LE slave host receives this request, it will respond with a Command Reject (L2CAP_CmdReject) with reason 0x0000 (command not understood). Page 153 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 16. L2CAP Vendor Specific Events All L2CAP events have the following format: Name Size (octets) Description Opcode 2 PDU operation code status 1 Event status connectionHandle 2 Connection Handle of link Event PDU Variable Event parameters Event Status: Value Parameter Description 0x00 SUCCESS 0x14 bleNotConnected 0x17 bleTimeout For the event parameters, please see the corresponding section below. 16.1 L2CAP_CmdRejct (0x0481) The Command Reject is sent in response to a command with an unknown command code or when sending the corresponding response is inappropriate. Event Parameters: reason: (2 octets) Value Parameter Description 0x0000 Command not understood 0x0001 Signaling MTU exceeded 0x0002 Invalid CID in request 16.2 L2CAP_ConnParamUpdateRsp (0x0493) This Connection Parameter Update Response is sent from the LE master device to the LE slave device. This response is sent by the master Host when it receives a Connection Parameter Update Request packet. Event Parameters: Page 154 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide result: (2 octets) Value Parameter Description 0x0000 Connection Parameters accepted 0x0001 Connection Parameters rejected 16.3 L2CAP_ConnectReq (0x0494) This Connection Request event is sent to the application since the application has wished to perform its own security verification (configured at PSM registration). After receiving a Connection Request, the application must respond back with a Connection Response (L2CAP_ConnectRsp) command indicating the outcome of the connection request. Event Parameters: id: (1 octet) Range Parameter Description 0x01 – 0xFF Identifier to match responses with requests (i.e., id to send back with L2CAP Connect Response command) PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM receiving connect request sourceCID: (2 octets) Range Parameter Description 0x0040 – 0x007F Represents CID on device sending connect request and receiving connect response (i.e., peer CID) MTU: (2 octets) Value Parameter Description 0xXXXX Specifies maximum SDU size that can be received on this channel on the peer device MPS: (2 octets) Value Parameter Description 0xXXXX Specifies maximum payload size that can be received on this channel on the peer device initialCredits: (2 octets) Page 155 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0xXXXX Indicates number of LE-frames that peer device can receive on this channel 16.4 L2CAP_ChannelEstablished (0x04E0) This Channel Established Event is generated when a Connection Oriented Channel has been established with the peer device. If result is successful (0x0000) then all other fields of the event will be present and can be accessed. Event Parameters: result: (2 octets) Value Parameter Description 0x0000 Connection successful 0x0001 Reserved 0x0002 Connection refused – LE PSM not supported 0x0003 Reserved 0x0004 Connection refused – no resources available 0x0005 Connection refused – insufficient authentication 0x0006 Connection refused – insufficient authorization 0x0007 Connection refused – insufficient encryption key size 0x0008 Connection refused – insufficient encryption 0x0009 – 0xFFFF Reserved PSM: (2 octets) Range Parameter Description 0x0001 – 0x00FF Local PSM that channel belongs to CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID MTU: (2 octets) Value Parameter Description 0xXXXX Maximum SDU size that can be received by the local device on this channel Page 156 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide MPS: (2 octets) Value Parameter Description 0xXXXX Maximum payload size that can be received by the local device credits: (2 octets) Value Parameter Description 0xXXXX Number of LE-frames that the local device can send peerCID: (2 octets) Range Parameter Description 0x0040 – 0x007F Remote Channel ID peerMTU: (2 octets) Value Parameter Description 0xXXXX Maximum SDU size that can be received by the peer device peerMPS: (2 octets) Value Parameter Description 0xXXXX Maximum payload size that can be received by the peer device peerCredits: (2 octets) Value Parameter Description 0xXXXX Number of LE-frames that the peer device can send peerCreditThreshold: (2 octets) Value Parameter Description 0xXXXX Low threshold for the peer credit count 16.5 L2CAP_ChannelTerminated (0x04E1) This Channel Terminated Event is generated when a Connection Oriented Channel has been terminated between the local and the peer device. Page 157 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID peerCID: (2 octets) Range Parameter Description 0x0040 – 0x007F Remote Channel ID reason: (2 octets) Value Parameter Description 0x0000 Physical link has gone down 0x0001 Channel terminated by the local PSM 0x0002 Channel terminated by the peer PSM 0x0003 Credit count exceeded 65535 0x0004 Total length of the payload received exceeded the SDU length specified in the first LE-frame of the SDU 0x0005 Total length of the payload received exceeded the local PSM's MTU 0x0006 LE-frame was received from the peer device that has a credit of count zero 0x0007 LE-frame was received with an error 0x0008 Error happened while trying to send an LE-frame 0x0009 Memory allocation error occurred 16.6 L2CAP_OutOfCredit (0x04E2) This Out Of Credit Event is generated when a Connection Oriented Channel runs out of credits needed to transmit an SDU to the peer device. Event Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID peerCID: (2 octets) Range Parameter Description Page 158 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Range Parameter Description 0x0040 – 0x007F Remote Channel ID creditsNeeded: (2 octets) Value Parameter Description 0xXXXX Number of credits needed to transmit the remaining part of the current SDU 16.7 L2CAP_PeerCreditThreshold (0x04E3) This Peer Credit Threshold Event is generated when an L2CAP Connection Oriented Channel reaches a low threshold specified for the peer credit count (configured at PSM registration). Event Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID peerCID: (2 octets) Range Parameter Description 0x0040 – 0x007F Remote Channel ID peerCreditThreshold: (2 octets) Value Parameter Description 0xXXXX Low threshold for the peer credit count 16.8 L2CAP_SendSduDone (0x04E4) This Send SDU Done Event is generated when the transmission of an SDU is completed on a Connection Oriented Channel established with the peer device. Event Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID credits: (2 octets) Page 159 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0xXXXX Remaining local credits peerCID: (2 octets) Range Parameter Description 0x0040 – 0x007F Remote Channel ID peerCredits: (2 octets) Value Parameter Description 0xXXXX Remaining peer credits totalLen: (2 octets) Value Parameter Description 0xXXXX Total length of the SDU being transmitted txLen: (2 octets) Value Parameter Description 0xXXXX Total number of octets transmitted 16.9 L2CAP_Data (0x04F0) This Data Event is generated when an SDU is received on a Connection Oriented Channel from the peer device. Event Parameters: CID: (2 octets) Range Parameter Description 0x0040 – 0x007F Local Channel ID len: (2 octets) Value Parameter Description 0xXXXX Total length of the SDU being received SDU: ( octets) Value Parameter Description Page 160 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description “XX:..XX” Received SDU Page 161 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 17. ATT Vendor Specific Commands and Events Most of the ATT requests and responses have two associated opcodes, command and event, due to Request and Response Tunneling as per section 9.3. 17.1 ATT Vendor Specific Commands All ATT commands have the following format: Name Size (octets) Description Opcode 2 PDU operation code connectionHandle 2 Connection Handle of link Command PDU Variable Command parameters Note: The connection handle of 0xFFFE is considered as the loopback connection. All messages sent to this connection will be loop backed to the local host. For the command parameters, please see the corresponding section below. Event(s) Generated: When an ATT command is received, the host will send the Command Status Event with the Status parameter. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x13 bleMemAllocError 0x14 bleNotConnected 0x16 blePending 0x19 bleLinkEncrypted 0x40 bleInvalidPDU 0x41 bleInsufficientAuthen 0x42 bleInsufficientEncrypt 0x43 bleInsufficientKeySize Page 162 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 17.2 ATT Vendor Specific Events All ATT events have the following format: Name Size (octets) Description Opcode 2 PDU operation code status 1 Event status connectionHandle 2 Connection Handle of link pduLen 1 Length of event PDU Event PDU Variable Event parameters Event Status: Value Parameter Description 0x00 SUCCESS 0x14 bleNotConnected 0x17 bleTimeout 0x1A bleProcedureComplete For the event parameters, please see the corresponding section below. Note: The connection handle of 0xFFFE is considered as the loopback connection. All messages sent to this connection will be loop backed to the local host. 17.3 ATT_ErrorRsp (Command = 0xFD01, Event = 0x0501) The Error Response is used to state that a given request cannot be performed and to provide the reason. Note: The Write Command does not generate an Error Response. Response Parameters: reqOpcode: (1 octet) Value XX Parameter Description The request that generated this error response handle: (2 octets) Range 0x0001 – 0xFFFF The attribute handle that generated this error response Page 163 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide errCode: (1 octet) Value Parameter Description The attribute handle given was not valid on this server. 0x01 The attribute cannot be read. 0x02 The attribute cannot be written. 0x03 The attribute PDU was invalid. 0x04 The attribute requires authentication before it can be read or written. Attribute server does not support the request received from the client. Offset specified was past the end of the attribute. 0x05 0x06 0x07 The attribute requires authorization before it can be read or written. Too many prepare writes have been queued. 0x08 0x09 No attribute found within the given attribute handle range. 0x0A The attribute cannot be read or written using the Read Blob Request. The Encryption Key Size used for encrypting this link is insufficient. The attribute value length is invalid for the operation. 0x0B 0x0C 0x0D The attribute request that was requested has encountered an error that was unlikely, and therefore could not be completed as requested. The attribute requires encryption before it can be read or written. The attribute type is not a supported grouping attribute as defined by a higher layer specification. Insufficient Resources to complete the request. 0x0E 0x0F 0x10 0x11 The attribute value is invalid for the operation. 0x80 17.4 ATT_ExchangeMTUReq (Command = 0xFD02, Event = 0x0502) The Exchange MTU Request is used by the client to inform the server of the client’s maximum receive MTU size and request the server to respond with its maximum receive MTU size is used to state that a given request cannot be performed and to provide the reason. Request Parameters: clientRxMTU: (2 octets) Value XX Parameter Description Client receive MTU size Page 164 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event(s) Generated: When this request is received, the server will send the Exchange MTU Response. 17.5 ATT_ExchangeMTURsp (Command = 0xFD03, Event = 0x0503) The Exchange MTU Response is sent in reply to a received Exchange MTU Request. Response Parameters: serverRxMTU: (2 octets) Value XX Parameter Description Attribute server receive MTU size 17.6 ATT_FindInfoReq (Command = 0xFD04, Event = 0x0504) The Find Information Request is used to obtain the mapping of attribute handles with their associated types. This allows a client to discover the list of attributes and their types on a server. Request Parameters: startHandle: (2 octets) Value 0xXXXX Parameter Description First requested handle number endHandle: (2 octets) Value 0xXXXX Parameter Description Last requested handle number Event(s) Generated: When this request is received, the server will send the Find Information Response. The client will forward all the Find Information Responses to the calling application. The response with the status of bleProcedureComplete will indicate the end of the sub-procedure. If no attributes will be returned or any of the requested parameters is invalid, the server will send an Error Response. 17.7 ATT_FindInfoRsp (Command = 0xFD05, Event = 0x0505) The Find Information Response is sent in reply to a received Find Information Request and contains information about the server. Page 165 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Response Parameters: format: (1 octet) Value 0x01 0x02 Parameter Description A list of 1 or more handles with their 16-bit Bluetooth UUIDs A list of 1 or more handles with their 128-bit UUIDs info: (4 to (ATT_MTU - 2) octets) Value “XX:XX:XX:XX…XX” Parameter Description The information data whose format is determined by the format field The information data field is comprised of a list of data defined in the tables below depending on the value chosen for the format. format = 0x01 (handles and their 16-bit Bluetooth UUIDs) Handle 2 octets 16-bit Bluetooth UUID 2 octets format = 0x02 (handles and their 128-bit UUIDs) Handle 2 octets 128-bit UUID 16 octets 17.8 ATT_FindByTypeValueReq (Command = 0xFD06, Event = 0x0506) The Find By Type Value Request is used to obtain the handles of attributes that have a 16-bit UUID attribute type and attribute value. This allows the range of handles associated with a given attribute to be discovered when the attribute type determines the grouping of a set of attributes. Request Parameters: startHandle: (2 octets) Value 0xXXXX Parameter Description First requested handle number endHandle: (2 octets) Value 0xXXXX Parameter Description Last requested handle number Page 166 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide type: (2 octets) Value Parameter Description 2 octet UUID to find “XX:XX” value: (0 to (ATT_MTU - 7) octets) Value Parameter Description Attribute value to find “XX:XX…XX” Event(s) Generated: When this request is received, the server will send the Find By Type Value Response. The client will forward all the Find By Type Value Responses to the calling application. The response with the status of bleProcedureComplete will indicate the end of the sub-procedure. If no attributes will be returned or any of the requested parameters is invalid, the server will send an Error Response. 17.9 ATT_FindByTypeValueRsp (Command = 0xFD07, Event = 0x0507) The Find By Type Value Response is sent in reply to a received Find By Type Value Request and contains information about this server. Response Parameters: handlesInfo: (4 to (ATT_MTU - 1) octets) Value Parameter Description A list of 1 or more Handle Information. “XX:XX:XX:XX…XX” The Handles Information List field is a list of one or more Handle Information. The Handles Information field is an attribute handle range as defined in Format of the Handles Information table below: Format of Handles Information Found Attribute Handle Handle Group End Handle 2 octets 2 octets 17.10 ATT_ReadByTypeReq (Command = 0xFD08, Event = 0x0508) The Read By Type Request is used to obtain the values of attributes where the attribute type is known but the handle is not known. Request Parameters: Page 167 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide startHandle: (2 octets) Value Parameter Description First requested handle number 0xXXXX endHandle: (2 octets) Value Parameter Description Last requested handle number 0xXXXX type: (2 or 16 octets) Value “XX:XX” or “XX:XX…XX” Parameter Description 2 or 16 octet UUID Event(s) Generated: When this request is received, the server will send the Read By Type Response. The client will forward all the Read By Type Responses to the calling application. The response with the status of bleProcedureComplete will indicate the end of the sub-procedure. If no attribute with the given type exists within the handle range or the attribute value cannot be read, the server will send an Error Response. 17.11 ATT_ReadByTypeRsp (Command = 0xFD09, Event = 0x0509) The Read By Type Response is sent in reply to a received Read By Type Request and contains the handles and values of the attributes that have been read. Response Parameters: length: (1 octet) Value Parameter Description The size of each attribute handle-value pair 0xXX data: (2 to (ATT_MTU-2) octets) Value Parameter Description A list of Attribute Data. “XX:XX…XX” The Attribute Data field is comprised of a list of attribute handle and value pairs as defined in Format of the Attribute Data table below: Format of Attribute Data Attribute Handle Attribute Value Page 168 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Attribute Handle Attribute Value 2 octets (Length - 2) octets 17.12 ATT_ReadReq (Command = 0xFD0A, Event = 0x050A) The Read Request is used request the server to read the value of an attribute and return its value in a Read Response. Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be read Event(s) Generated: When this request is received, the server will send the Read Response. If the attribute handle is invalid or the attribute value cannot be read, the server will send an Error Response. 17.13 ATT_ReadRsp (Command = 0xFD0B, Event = 0x050B) The Read Response is sent in reply to a received Read Request and contains the value of the attribute that has been read. Response Parameters: value: (0 to (ATT_MTU - 1) octets) Value “XX:XX…XX” Parameter Description The value of the attribute with the handle given 17.14 ATT_ReadBlobReq (Command = 0xFD0C, Event = 0x050C) The Read Blob Request is used request the server to read part of the value of an attribute at a given offset and return a specific part of the value in a Read Blob Response. Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be read Page 169 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide offset: (2 octets) Value 0xXXXX Parameter Description The offset of the first octet to be read Event(s) Generated: When this request is received, the server will send the Read Blob Response. The client will forward all the Read Blob Responses to the calling application. The response with the status of bleProcedureComplete will indicate the end of the sub-procedure. If the attribute handle or offset is invalid, or the attribute value cannot be read, the server will send an Error Response. 17.15 ATT_ReadBlobRsp (Command = 0xFD0D) The Read Blob Response is sent in reply to a received Read Blob Request and contains part of the value of the attribute that has been read. Response Parameters: value: (0 to (ATT_MTU - 1) octets) Value “XX:XX…XX” Parameter Description Part of the value of the attribute with the handle given 17.16 ATT_ReadMultiReq (Command = 0xFD0E, Event = 0x050E) The Read Multiple Request is used to request the server to read two or more values of a set of attributes and return their values in a Read Multiple Response. Only values that have a known fixed size can be read, with the exception of the last value that can have a variable length. Request Parameters: handles: (4 to (ATT_MTU-1) octets) Value “XX:XX:XX:XX…XX” Parameter Description A set of two or more attribute handles. Event(s) Generated: When this request is received, the server will send the Read Multiple Response. If any of the attribute handles are invalid or any of the attribute values cannot be read, the server will send an Error Response. Page 170 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 17.17 ATT_ReadMultiRsp (Command = 0xFD0F, Event = 0x050F) The Read Multiple Response is sent in reply to a received Read Multiple Request and contains the values of the attributes that have been read. Response Parameters: values: (0 to (ATT_MTU - 1) octets) Value Parameter Description A set of two or more values. “XX…XX” 17.18 ATT_ReadByGrpTypeReq (Command = 0xFD10, Event = 0x0510) The Read By Group Type Request is used to obtain the values of attributes where the attribute type is known, the type of a grouping attribute as defined by a higher layer specification, but the handle is not known. Request Parameters: startHandle: (2 octets) Value Parameter Description First requested handle number 0xXXXX endHandle: (2 octets) Value Parameter Description Last requested handle number 0xXXXX groupType: (2 or 16 octets) Value “XX:XX” or “XX:XX…XX” Parameter Description 2 or 16 octet UUID Event(s) Generated: When this request is received, the server will send the Read By Group Type Response. The client will forward all the Read By Group Type Responses to the calling application. The response with the status of bleProcedureComplete will indicate the end of the sub-procedure. If no attributes with the given type exists within the handle ranges or the Attribute Group Type is not a supported grouping attribute, the server will send an Error Response. Page 171 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 17.19 ATT_ReadByGrpTypeRsp (Command = 0xFD11, Event = 0x0511) The Read By Group Type Response is sent in reply to a received Read By Group Type Request and contains the handles and values of the attributes that have been read. Response Parameters: length: (1 octet) Value Parameter Description The size of each attribute handle-value pair 0xXX attrData: (2 to (ATT_MTU - 2) octets) Value Parameter Description A list of Attribute Data. “XX:XX:…XX” The Attribute Data field is comprised of a list of attribute handle and value pairs as defined in Format of the Attribute Data table below: Format of Attribute Data Attribute Handle End Group Handle Attribute Value 2 octets 2 octets (Length - 4) octets 17.20 ATT_WriteReq (Command = 0xFD12, Event = 0x0512) The Write Request is used to request the server to write the value of an attribute and acknowledge that this has been achieved in a Write Response. The command field is set for the Write Command. The signature and command fields are set for the Signed Write Command. Request Parameters: The signature field represents different data as defined in the tables below depending on the type of the message. signature: (1 octet) – when the field is part of a command Value 0x00 0x01 Parameter Description Do not include the Authentication Signature with the Write PDU. Include the Authentication Signature with the Write PDU. signature: (1 octet) - when the field is part of an event Page 172 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value 0x00 0x01 0x02 Parameter Description The Authentication Signature is not included with the Write PDU. The included Authentication Signature is valid. The included Authentication Signature is not valid. command: (1 octet) Value 0x00 or 0x01 Parameter Description Whether this is a Write Command: 0x00 - No 0x01 - Yes handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. value: (0 to (ATT_MTU - 3) octets) Value “XX…XX” Parameter Description The value to be written to the attribute. Event(s) Generated: When this request is received, the server will send the Write Response. If the attribute handle is invalid or the attribute value cannot be written, the server will send an Error Response. The server will not send an Error Response for the Write Command. 17.21 ATT_WriteRsp (Command = 0xFD13, Event = 0x0513) The Write Response is sent in reply to a valid Write Request and acknowledges that the attribute has been successfully written. Response Parameters: None 17.22 ATT_PrepareWriteReq (Command = 0xFD16, Event = 0x0516) The Prepare Write Request is used to request the server to prepare to write the value of an attribute. The server will respond to this request with a Prepare Write Response, so that the client can verify that the value was received correctly. A client may send more than one Prepare Write Request to a server, which will queue and send a response for each handle value pair. Page 173 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. offset: (2 octets) Value 0xXXXX Parameter Description The offset of the first octet to be Written. value: (0 to (ATT_MTU - 5) octets) Value “XX…XX” Parameter Description Part of the value of the attribute to be written. Event(s) Generated: When this request is received, the server will send the Prepare Write Response. The client will forward the response to the calling application only when the compile option TESTMODES is used. If the attribute handle is invalid or the attribute value cannot be written, the server will send an Error Response. 17.23 ATT_PrepareWriteRsp (Command = 0xFD17, Event = 0x0517) The Prepare Write Response is sent in response to a received Prepare Write Request and acknowledges that the value has been successfully received and placed in the prepare write queue. Response Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. offset: (2 octets) Value 0xXXXX Parameter Description The offset of the first octet to be Written. value: (0 to (ATT_MTU - 5) octets) Value “XX…XX” Parameter Description Part of the value of the attribute to be written. Page 174 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 17.24 ATT_ExecuteWriteReq (Command = 0xFD18, Event = 0x0518) The Execute Write Request is used to request the server to write or cancel the write of all the prepared values currently held in the prepare queue from this client. This request shall be handled by the server as an atomic operation. Request Parameters: flags: (1 octet) Value Parameter Description Cancel all prepared writes 0x00 Immediately write all pending prepared values 0x01 Event(s) Generated: When this request is received, the server will send the Execute Write Response. If the attribute value cannot be written, the server will send an Error Response. 17.25 ATT_ExecuteWriteRsp (Command = 0xFD19, Event = 0x0519) The Execute Write Response is sent in response to a received Execute Write Request. Response Parameters: None 17.26 ATT_HandleValueNoti (Command = 0xFD1B, Event = 0x051B) A server can send a notification of an attribute’s value at any time. Request Parameters: authenticated: (1 octet) Value 0x00 or 0x01 Parameter Description Whether or not an authenticated link is required: 0x00 - No 0x01 - Yes handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute. Page 175 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide value: (0 to (ATT_MTU - 3) octets) Value Parameter Description The current value of the attribute. “XX…XX” Event(s) Generated: None 17.27 ATT_HandleValueInd (Command = 0xFD1D, Event = 0x051D) A server can send an indication of an attribute’s value at any time. Request Parameters: authenticated: (1 octet) Value 0x00 or 0x01 Parameter Description Whether or not an authenticated link is required: 0x00 - No 0x01 - Yes handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute. value: (0 to (ATT_MTU - 3) octets) Value “XX…XX” Parameter Description The current value of the attribute. Event(s) Generated: The client shall send a Handle Value Confirmation in response to a Handle Value Indication. No further indications to this client shall occur until the confirmation has been received by the server. 17.28 ATT_HandleValueCfm (Command = 0xFD1E, Event = 0x051E) The Handle Value Confirmation is sent in response to a received Handle Value Indication and confirms that the client has received an indication of the given attribute. Request Parameters: None Page 176 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 17.29 ATT_FlowCtrlViolatedEvt (0x057E) The ATT Flow Control Violated Event is sent to the application by the ATT Server or Client when a sequential ATT Request-Response or Indication-Confirmation protocol flow control is violated for a connection. All subsequent ATT Requests and Indications received by the ATT Server and Client respectively will be dropped. This message is to inform the application in case it wants to drop the connection. Event Parameters: opcode: (1 octet) Value Parameter Description Opcode of message that caused flow control violation XX pendingOpcode: (1 octet) Value XX Parameter Description Opcode of pending message Event(s) Generated: When a sequential ATT Request-Response or Indication-Confirmation protocol flow control is violated for a connection, the local ATT Server or Client sends out this event. 17.30 ATT_MtuUpdatedEvt (0x057F) The ATT MTU Updated Event is sent out by the local ATT Server or Client when the ATT MTU size is updated for a connection. The default ATT MTU size is 23 octets. This message is to inform the application about the new ATT MTU size negotiated for a connection. Event Parameters: MTU: (2 octets) Value XX:XX Parameter Description New MTU size Event(s) Generated: When the ATT MTU size is changed for a connection, the local ATT Server or Client sends out this event. Page 177 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 18. GATT Vendor Specific Commands All GATT commands have the following format: Name Size (octets) Description Opcode 2 PDU operation code connectionHandle 2 Connection Handle of link Command PDU Variable Command parameters Note: The connection handle of 0xFFFE is considered as the loopback connection. All messages sent to this connection will be loop backed to the local host. For the command parameters, please see the corresponding section below. Event(s) Generated: When a GATT command is received, the host will send the Command Status Event with the Status parameter. Return Parameters: Status: (1 octet) Value Parameter Description 0x00 SUCCESS 0x02 INVALIDPARAMETER 0x04 MSG_BUFFER_NOT_AVAIL 0x13 bleMemAllocError 0x14 bleNotConnected 0x40 bleInvalidPDU 18.1 GATT_ExchangeMTU (0xFD82) This sub-procedure is used by a client to set the ATT_MTU to the maximum possible value that can be supported by both devices when the client supports a value greater than the default ATT_MTU for the Attribute Protocol. This sub-procedure shall only be initiated once during a connection. The ATT Exchange MTU Request is used by this sub-procedure. Request Parameters: Please refer to Section 17.4 for the format of the request parameters. Event(s) Generated: Page 178 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide This sub-procedure is complete when either ATT_ExchangeMTURsp (with SUCCESS or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.2 GATT_DiscAllPrimaryServices (0xFD90) This sub-procedure is used by a client to discover all the primary services on a server. The ATT Read By Group Type Request is used with the Attribute Type parameter set to the UUID for "Primary Service". The Starting Handle is set to 0x0001 and the Ending Handle is set to 0xFFFF. Request Parameters: None. Event(s) Generated: This sub-procedure is complete when either ATT_ReadByGrpTypeRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.3 GATT_DiscPrimaryServiceByUUID (0xFD86) This sub-procedure is used by a client to discover a specific primary service on a server when only the Service UUID is known. The specific primary service may exist multiple times on a server. The primary service being discovered is identified by the service UUID. The ATT Find By Type Value Request is used with the Attribute Type parameter set to the UUID for "Primary Service" and the Attribute Value set to the 16-bit Bluetooth UUID or 128-bit UUID for the specific primary service. The Starting Handle shall be set to 0x0001 and the Ending Handle shall be set to 0xFFFF. Request Parameters: value: (0 to (ATT_MTU - 7) octets) Value “XX:XX…XX” Parameter Description Attribute value to find Event(s) Generated: This sub-procedure is complete when either ATT_FindByTypeValueRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.4 GATT_FindIncludedServices (0xFDB0) This sub-procedure is used by a client to find include service declarations within a service definition on a server. The service specified is identified by the service handle range. Page 179 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide The ATT Read By Type Request is used with the Attribute Type parameter set to the UUID for "Included Service". The Starting Handle is set to starting handle of the specified service and the Ending Handle is set to the ending handle of the specified service. Request Parameters: startHandle: (2 octets) Value 0xXXXX Parameter Description First requested handle number endHandle: (2 octets) Value 0xXXXX Parameter Description Last requested handle number Event(s) Generated: This sub-procedure is complete when either ATT_ReadByTypeRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.5 GATT_DiscAllChars (0xFDB2) This sub-procedure is used by a client to find all the characteristic declarations within a service definition on a server when only the service handle range is known. The service specified is identified by the service handle range. The ATT Read By Type Request is used with the Attribute Type parameter set to the UUID for "Characteristic". The Starting Handle is set to starting handle of the specified service and the Ending Handle is set to the ending handle of the specified service. Request Parameters: startHandle: (2 octets) Value 0xXXXX Parameter Description First requested handle number endHandle: (2 octets) Value 0xXXXX Parameter Description Last requested handle number Event(s) Generated: This sub-procedure is complete when either ATT_ReadByTypeRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. Page 180 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 18.6 GATT_DiscCharsByUUID (0xFD88) This sub-procedure is used by a client to discover service characteristics on a server when only the service handle ranges are known and the characteristic UUID is known. The specific service may exist multiple times on a server. The characteristic being discovered is identified by the characteristic UUID. The ATT Read By Type Request is used with the Attribute Type is set to the UUID for "Characteristic" and the Starting Handle and Ending Handle parameters is set to the service handle range. Request Parameters: startHandle: (2 octets) Value Parameter Description First requested handle number 0xXXXX endHandle: (2 octets) Value Parameter Description Last requested handle number 0xXXXX type: (2 or 16 octets) Value “XX:XX” or “XX:XX…XX” Parameter Description 2 or 16 octet UUID Event(s) Generated: This sub-procedure is complete when either ATT_ReadByTypeRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.7 GATT_DiscAllCharDescs (0xFD84) This sub-procedure is used by a client to find all the characteristic descriptor’s Attribute Handles and Attribute Types within a characteristic definition when only the characteristic handle range is known. The characteristic specified is identified by the characteristic handle range. The ATT Find Information Request is used with the Starting Handle set to starting handle of the specified characteristic and the Ending Handle set to the ending handle of the specified characteristic. The UUID Filter parameter is NULL (zero length). Request Parameters: Please refer to Section 17.6 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_FindInfoRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. Page 181 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 18.8 GATT_ReadCharValue (0xFD8A) This sub-procedure is used to read a Characteristic Value from a server when the client knows the Characteristic Value Handle. The ATT Read Request is used with the Attribute Handle parameter set to the Characteristic Value Handle. The Read Response returns the Characteristic Value in the Attribute Value parameter. The Read Response only contains a Characteristic Value that is less than or equal to (ATT_MTU – 1) octets in length. If the Characteristic Value is greater than (ATT_MTU – 1) octets in length, the Read Long Characteristic Value procedure may be used if the rest of the Characteristic Value is required. Request Parameters: Please refer to Section 17.12 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_ReadRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.9 GATT_ReadUsingCharUUID (0xFDB4) This sub-procedure is used to read a Characteristic Value from a server when the client only knows the characteristic UUID and does not know the handle of the characteristic. The ATT Read By Type Request is used to perform the sub-procedure. The Attribute Type is set to the known characteristic UUID and the Starting Handle and Ending Handle parameters shall be set to the range over which this read is to be performed. This is typically the handle range for the service in which the characteristic belongs. Request Parameters: Please refer to Section 17.10 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_ReadByTypeRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.10 GATT_ReadLongCharValue (0xFD8C) This sub-procedure is used to read a Characteristic Value from a server when the client knows the Characteristic Value Handle and the length of the Characteristic Value is longer than can be sent in a single Read Response Attribute Protocol message. The ATT Read Blob Request is used in this sub-procedure. Page 182 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Request Parameters: Please refer to Section 17.14 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_ReadBlobRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.11 GATT_ReadMultiCharValues (0xFD8E) This sub-procedure is used to read multiple Characteristic Values from a server when the client knows the Characteristic Value Handles. The Attribute Protocol Read Multiple Requests is used with the Set Of Handles parameter set to the Characteristic Value Handles. The Read Multiple Response returns the Characteristic Values in the Set Of Values parameter. The ATT Read Multiple Request is used in this sub-procedure. Request Parameters: Please refer to Section 17.16 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_ReadMultiRsp (with SUCCESS or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.12 GATT_WriteNoRsp (0xFDB6) This sub-procedure is used to write a Characteristic Value to a server when the client knows the Characteristic Value Handle and the client does not need an acknowledgement that the write was successfully performed. This sub-procedure only writes the first (ATT_MTU – 3) octets of a Characteristic Value. This sub-procedure can not be used to write a long characteristic; instead the Write Long Characteristic Values sub-procedure should be used. The ATT Write Command is used for this sub-procedure. The Attribute Handle parameter shall be set to the Characteristic Value Handle. The Attribute Value parameter shall be set to the new Characteristic Value. Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. value: (0 to (ATT_MTU - 3) octets) Value Parameter Description Page 183 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value “XX…XX” Parameter Description The value to be written to the attribute. Event(s) Generated: No response will be sent to the calling application task for this sub-procedure. If the Characteristic Value write request is the wrong size, or has an invalid value as defined by the profile, then the write will not succeed and no error will be generated by the server. 18.13 GATT_SignedWriteNoRsp (0xFDB8) This sub-procedure is used to write a Characteristic Value to a server when the client knows the Characteristic Value Handle and the ATT Bearer is not encrypted. This sub-procedure shall only be used if the Characteristic Properties authenticated bit is enabled and the client and server device share a bond as defined in the GAP. This sub-procedure only writes the first (ATT_MTU – 15) octets of an Attribute Value. This subprocedure cannot be used to write a long Attribute. The ATT Write Command is used for this sub-procedure. The Attribute Handle parameter shall be set to the Characteristic Value Handle. The Attribute Value parameter shall be set to the new Characteristic Value authenticated by signing the value, as defined in the Security Manager. Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. value: (0 to (ATT_MTU - 3) octets) Value “XX…XX” Parameter Description The value to be written to the attribute. Event(s) Generated: No response will be sent to the calling application task for this sub-procedure. If the authenticated Characteristic Value that is written is the wrong size, or has an invalid value as defined by the profile, or the signed value does not authenticate the client, then the write will not succeed and no error will be generated by the server. 18.14 GATT_WriteCharValue (0xFD92) This sub-procedure is used write a characteristic value to a server when the client knows the characteristic value handle. This sub-procedure only writes the first (ATT_MTU-3) octets of a characteristic value. This sub-procedure can not be used to write a long attribute; instead the Write Long Characteristic Values sub-procedure should be used. Page 184 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide The ATT Write Request is used in this sub-procedure. The Attribute Handle parameter shall be set to the Characteristic Value Handle. The Attribute Value parameter shall be set to the new characteristic. Request Parameters: Please refer to Section 17.20 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_WriteRsp (with SUCCESS or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.15 GATT_WriteLongCharValue (0xFD96) This sub-procedure is used to write a Characteristic Value to a server when the client knows the Characteristic Value Handle but the length of the Characteristic Value is longer than can be sent in a single Write Request Attribute Protocol message. The ATT Prepare Write Request and Execute Write Request are used to perform this sub-procedure. Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. offset: (2 octets) Value 0xXXXX Parameter Description The offset of the first octet to be Written. value: (0 to 512 octets) Value “XX…XX” Parameter Description The value of the attribute to be written. Note: the stack implementation supports the maximum length of 512 octets but this is always bound by the physical interface used to communicate with the device. Event(s) Generated: This sub-procedure is complete when either ATT_PrepareWriteRsp (with bleTimeout status), ATT_ExecuteWriteRsp (with SUCCESS or bleTimeout status), or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. Page 185 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 18.16 GATT_ReliableWrites (0xFDBA) This sub-procedure is used to write a Characteristic Value to a server when the client knows the Characteristic Value Handle, and assurance is required that the correct Characteristic Value is going to be written by transferring the Characteristic Value to be written in both directions before the write is performed. This sub-procedure can also be used when multiple values must be written, in order, in a single operation. The sub-procedure has two phases; the first phase prepares the characteristic values to be written. Once this is complete, the second phase performs the execution of all of the prepared characteristic value writes on the server from this client. In the first phase, the ATT Prepare Write Request is used. In the second phase, the attribute protocol Execute Write Request is used. Request Parameters: numberRequests: (1 octet) Value Parameter Description The number of Prepare Write Request messages. 0xXX requests: (0 to 512 octets) Value Parameter Description A list of Prepare Write Request messages. Note: the stack implementation supports the maximum length of 512 octets but this is always bound by the physical interface used to communicate with the device. “XX:XX:…XX” The Requests field is comprised of a list of Attribute Value Length and Prepare Write Request as defined in Format of the Requests table below: Format of Requests Attribute Value Length Prepare Write Request 1 octet Please see Section 17.22 for the format of Prepare Write Request Event(s) Generated: This sub-procedure is complete when either ATT_PrepareWriteRsp (with bleTimeout status), ATT_ExecuteWriteRsp (with SUCCESS or bleTimeout status), or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.17 GATT_ReadCharDesc (0xFDBC) This sub-procedure is used to read a Characteristic Descriptor from a server when the client knows the Characteristic Descriptor’s Handle. Page 186 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide The ATT Read Request is used for this sub-procedure. The Read Request is used with the Attribute Handle parameter set to the characteristic descriptor handle. The Read Response returns the characteristic descriptor value in the Attribute Value parameter. Request Parameters: Please refer to Section 17.12 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_ReadRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.18 GATT_ReadLongCharDesc (0xFDBE) This sub-procedure is used to read a Characteristic Descriptor from a server when the client knows the Characteristic Descriptor Declaration’s Attribute Handle and the length of the Characteristic Descriptor Declaration is longer than can be sent in a single Read Response Attribute Protocol message. The ATT Read Blob Request is used to perform this sub-procedure. The Attribute Handle parameter shall be set to the characteristic descriptor handle. The Value Offset parameter shall be the offset within the characteristic descriptor to be read. Request Parameters: Please refer to Section 17.14 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_ReadBlobRsp (with bleProcedureComplete or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.19 GATT_WriteCharDesc (0xFDC0) This sub-procedure is used write a characteristic descriptor to a server when the client knows the characteristic descriptor handle. The ATT Write Request is used for this sub-procedure. The Attribute Handle parameter shall be set to the characteristic descriptor handle. The Attribute Value parameter shall be set to the new characteristic descriptor value. Request Parameters: Please refer to Section 17.20 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when either ATT_WriteRsp (with SUCCESS or bleTimeout status) or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. Page 187 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 18.20 GATT_WriteLongCharDesc (0xFDC2) This sub-procedure is used to write a Characteristic Value to a server when the client knows the Characteristic Value Handle but the length of the Characteristic Value is longer than can be sent in a single Write Request Attribute Protocol message. The ATT Prepare Write Request and Execute Write Request are used to perform this sub-procedure. Request Parameters: handle: (2 octets) Value 0xXXXX Parameter Description The handle of the attribute to be Written. offset: (2 octets) Value 0xXXXX Parameter Description The offset of the first octet to be Written. value: (0 to 512 octets) Value “XX…XX” Parameter Description The value of the attribute to be written. Note: the stack implementation supports the maximum length of 512 octets but this is always bound by the physical interface used to communicate with the device. Event(s) Generated: This sub-procedure is complete when either ATT_PrepareWriteRsp (with bleTimeout status), ATT_ExecuteWriteRsp (with SUCCESS or bleTimeout status), or ATT_ErrorRsp (with SUCCESS status) is received by the calling application task. 18.21 GATT_Notification (0xFD9B) This sub-procedure is used when a server is configured to notify a characteristic value to a client without expecting any attribute protocol layer acknowledgement that the notification was successfully received. The ATT Handle Value Notification is used in this sub-procedure. Note: A notification may be sent at any time and does not invoke a confirmation. Request Parameters: Please refer to Section 17.26 for the format of the request parameters. Event(s) Generated: Page 188 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide None. 18.22 GATT_Indication (0xFD9D) This sub-procedure is used when a server is configured to indicate a characteristic value to a client and expects an attribute protocol layer acknowledgement that the indication was successfully received. The ATT Handle Value Indication is used in this sub-procedure. Request Parameters: Please refer to Section 17.27 for the format of the request parameters. Event(s) Generated: This sub-procedure is complete when ATT_HandleValueCfm (with SUCCESS or bleTimeout status) is received by the calling application task. 18.23 GATT_AddService (0xFDFC) This command is used to add a new service to the GATT Server on the Network Processor when the GATT Database is implemented on the Application Processor. The GATT_AddAttribute command described in Section 18.25 must be used to add additional attributes to the service. The new service will be automatically registered with the GATT Server if it has no additional attribute to be added. Note: The Command Status Event will have the Start Handle and End Handle for the service registered with the GATT Server. No ATT request is used to perform this command. Request Parameters: UUID: (2 octets) Value “00:28” or “01:28” Parameter Description The type of the service to be added: 0x2800 – Primary Service 0x2801 – Secondary Service numAttrs: (2 octets) Value “XX:XX” Parameter Description The number of the attributes in the service (including the service attribute). encKeySize: (1 octet) Value “XX” Parameter Description The minimum encryption key size (in octets) required by the service. Range: 7 to 16. Page 189 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Event(s) Generated: None. 18.24 GATT_DelService (0xFDFD) This command is used to delete a service from the GATT Server on the Network Processor when the GATT Database is implemented on the Application Processor. No ATT request is used to perform this command. Request Parameters: handle: (2 octets) Value “XX:XX” Parameter Description The handle of the service to be deleted (0x0000 if the service hasn’t been registered with the GATT Server yet). Event(s) Generated: None. 18.25 GATT_AddAttribute (0xFDFE) This command is used to add a new attribute to the service being added to the GATT Server on the Network Processor when the GATT Database is implemented on the Application Processor. The service will be automatically registered with the GATT Server when its last attribute is added. Note: The Command Status Event will have the Start Handle and End Handle for the service registered with the GATT Server. No ATT request is used to perform this command. Request Parameters: UUID: (2 or 16 octets) Value “XX:XX” or “XX:…:XX” Parameter Description The type of the attribute to be added to a service. permissions: Bit Mask (1 octet) Value Parameter Description 0x01 GATT_PERMIT_READ 0x02 GATT_PERMIT_WRITE 0x04 GATT_PERMIT_AUTHEN_READ Page 190 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0x08 GATT_PERMIT_AUTHEN_WRITE 0x10 GATT_PERMIT_AUTHOR_READ 0x20 GATT_PERMIT_AUTHOR_WRITE Event(s) Generated: None. Page 191 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 19. GATT Vendor Specific Events All GATT events have the following format: Name Size (octets) Description Opcode 2 PDU operation code status 1 Event status connectionHandle 2 Connection Handle of link pduLen 1 Length of event PDU Event PDU Variable Event parameters Event Status: Value Parameter Description 0x00 SUCCESS 0x14 bleNotConnected 0x17 bleTimeout 0x1A bleProcedureComplete For the event parameters, please see the corresponding section below. Note: The connection handle of 0xFFFE is considered as the loopback connection. All messages sent to this connection will be loop backed to the local host. 19.1 GATT_ClientCharCfgUpdated (0x0580) The Client Characteristic Configuration Updated event is generated whenever the Client Characteristic Configuration attribute value is updated for a connection (i.e., GATT client). Response Parameters: attributeHandle: (2 octets) Value Parameter Description The handle of the Client Characteristic Configuration attribute 0xXXXX value: Bit Mask (2 octets) Value Parameter Description 0x0000 No operation 0x0001 The Characteristic Value is configured to be notified Page 192 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide Value Parameter Description 0x0002 The Characteristic Value is configured to be indicated 0xFFF4 Reserved for future use Page 193 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 20. Host Error Codes This section lists the various possible error codes generated by the Host. If an HCI extension command that sent a Command Status with the error code ‘SUCCESS’ before processing may find an error during execution then the error is reported in the normal completion command for the original command. The error code 0x00 means SUCCESS. The possible range of failure error codes is 0x01-0xFF. The table below provides an error code description for each failure error code. Value Parameter Description 0x00 SUCCESS 0x01 FAILURE 0x02 INVALIDPARAMETER 0x03 INVALID_TASK 0x04 MSG_BUFFER_NOT_AVAIL 0x05 INVALID_MSG_POINTER 0x06 INVALID_EVENT_ID 0x07 INVALID_INTERRUPT_ID 0x08 NO_TIMER_AVAIL 0x09 NV_ITEM_UNINIT 0x0A NV_OPER_FAILED 0x0B INVALID_MEM_SIZE 0x0C NV_BAD_ITEM_LEN 0x10 bleNotReady 0x11 bleAlreadyInRequestedMode 0x12 bleIncorrectMode 0x13 bleMemAllocError 0x14 bleNotConnected 0x15 bleNoResources 0x16 blePending 0x17 bleTimeout 0x18 bleInvalidRange 0x19 bleLinkEncrypted 0x1A bleProcedureComplete 0x30 bleGAPUserCanceled 0x31 bleGAPConnNotAcceptable 0x32 bleGAPBondRejected 0x40 bleInvalidPDU Page 194 of 195 Copyright © 2014-2015 Texas Instruments Inc. TI BLE HCI Vendor Specific HCI Guide 0x41 bleInsufficientAuthen 0x42 bleInsufficientEncrypt 0x43 bleInsufficientKeySize 0xFF INVALID_TASK_ID Table 8: List of Possible Host Error Codes Page 195 of 195 Copyright © 2014-2015 Texas Instruments Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 195 Language : en-US Tagged PDF : Yes Title : TI BLE HCI Vendor Specific HCI Guide Author : Lefeuvre, Florian Creator : Microsoft® Word 2010 Create Date : 2015:04:23 15:55:51-07:00 Modify Date : 2015:04:23 15:55:51-07:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools