Thermo Scientific TVA 1000B Instruction Manual
TVA-1000B
User Manual: Pdf TVA-1000B
Open the PDF directly: View PDF .
Page Count: 197
Download | |
Open PDF In Browser | View PDF |
For Sales & Service Contact 2650 E. 40th Ave. • Denver, CO 80205 Phone 303-320-4764 • Fax 303-322-7242 1-800-833-7958 www.geotechenv.com TVA-1000B TOXIC VAPOR ANALYZER INSTRUCTION MANUAL P/N BK3500 THERMO ENVIRONMENTAL INSTRUMENTS INC. 8 WEST FORGE PARKWAY FRANKLIN, MASSACHUSETTS 02038 TELEPHONE: (508) 520-0430 FACSIMILE: (508) 520-1460 5-15-01 Other brands and product names mentioned in this instruction manual are trademarks of their respective owners. Copyright 2001 Thermo Environmental Instruments, Inc. Franklin, Massachusetts “This manual is a work protected under Copyright law. Copying or other reproduction of any of its contents without the prior written consent of Thermo Environmental Instruments is expressly prohibited.” Publications Comments Form Fax 508-520-1460 Document Part Number BK3500 Title Model TVA-1000B Instruction Manual We continually seek to improve the content and usability of our technical documents. You can help us by answering the questions below and mailing this form to us. How do you use this document? Introduction to the product Classroom resource Self-study Programming procedures Advanced programming techniques Operating instructions Reference Other How did you get this document? Received with equipment Received from Sales or Customer Service Representative Ordered from TEI Do not know Other Please rate this document. Technical Accuracy Does the system work as described in the manual? Readability Is the manual easy to read and understand? Clarity Are the instructions easy to follow? Examples Are the examples helpful and realistic? Are there enough examples? Organization Is the organization of the manual logical? Is it easy to find what you are looking for? Illustrations Are the illustrations clear and useful? Appearance What do you think of the layout, printing, binding, etc.? Excellent Good Yes No Yes No Poor Are there any terms or concepts that are not defined clearly? If so, what are they? ____________________________________________________________________________________ After reading this manual, are you able to use the equipment? What errors did you find in the manual? Please include page numbers. Attach extra sheets if necessary. ____________________________________________________________________________________ Do you have any comments or suggestions? ____________________________________________________________________________________ ____________________________________________________________________________________ Name: _____________________________________ Street: ____________________________________ Title: ______________________________________ City: ____________________________________ Dept./Mail Stop ____________________________ State/Country: _____________________________ Company: _________________________________ Zip Code: _________ Telephone: ______________ Thank you for your help. Sent by __________________________ __________________________ _______________________ Thermo Environmental Instruments, Inc. 8 West Forge Parkway Franklin, MA. 02038-3136 Attn: Technical Publications PLACE STAMP HERE TVA 1000B Toxic Vapor Analyzer July 28, 2000 Overall Table of Contents For Manual P/N BK3500 DOCUMENT DESCRIPTION MI 611-185 TVA-1000B Toxic Vapor Analyzer, Operation, Configuration, and Maintenance MI 611-187 TVA-1000 Toxic Vapor Analyzer PC Software Ml 611-186 PC Interface Program (PCIP) Software for Interfacing a PC and a TVA-I000B Toxic Vapor Analyzer Ml 611-183 CENTURY TVA-1000 ToxicVaporAnalyzer 11.8 eV PID Lamp Capsules (Part No. CR01 IYZ) Ml 611-182 WATERTRAP Probe (Part No. CRO13EA) PL 611-139 TVA-1000B Toxic Vapor Analyzer - Parts List Addendum Importing TVA-1000B Files into Microcoft Excel via the PCIP Software General Instructions TEI designs, manufactures, and tests its products to meet many national and international standards. However, for these products to operate within their normal specifications, you must properly install, use, and maintain these products. The following instructions must be adhered to and integrated with your safety program when installing, using, and maintaining Foxboro products. ♦ ♦ ♦ ♦ ♦ ♦ ♦ Read and save all instructions prior to installing, operating, and servicing the product. If you do not understand any of the instructions, contact your Foxboro representative for clarification. Follow all warnings, cautions, and instructions marked on and supplied with the product. Inform and educate your personnel in the proper installation, operation, and maintenance of the product. To ensure proper performance, use qualified personnel to operate, update, program, and maintain the product. When replacement parts are required, ensure that the qualified service technician uses replacement parts specified by Foxboro. Unauthorized substitutions may result in fire, electrical shock, other hazards, or improper operation of equipment. Except when maintenance is being performed by qualified personnel, ensure that all equipment doors are closed and protective covers are in place, to prevent electrical shock and personal injury. ix MI 611-185 – June 1996 x General Instructions Instruction MI 611-185 1-22-01 TVA-1000B Toxic Vapor Analyzer Operation, Configuration, and Maintenance Style AA Copyright 2001 by Thermo Environmental Instruments All rights reserved MI 611-185 – January 2001 Contents Figures............................................................................................................................. vii Tables............................................................................................................................. viii General Instructions ......................................................................................................... ix Introduction ..................................................................................................................... Overview ............................................................................................................................. Instrument Functions .......................................................................................................... Using the Instrument .......................................................................................................... Standard Specifications ....................................................................................................... External Influences .............................................................................................................. Product Safety Specifications ............................................................................................... 1 1 2 2 3 5 6 Theory of Operation ........................................................................................................ 7 Flame Ionization Detection (FID) ....................................................................................... 7 Benefits of Flame Ionization Detection ........................................................................... 8 Photoionization Detection .................................................................................................. 8 Benefits of Photoionization Detection ............................................................................ 8 Dual Detectors .................................................................................................................... 9 Benefits of Dual Detectors .............................................................................................. 9 Concentration Calculation and Calibration ....................................................................... 10 Hardware ....................................................................................................................... Instrument Connections ................................................................................................... Analog Outputs ................................................................................................................ Instrument Sidepack Display ............................................................................................ Instrument Sidepack Keypad ............................................................................................. Probe Connections ............................................................................................................ BASIC Probe Display ........................................................................................................ BASIC Probe Keys ............................................................................................................ Enhanced Probe Display ................................................................................................... Enhanced Probe Keys ........................................................................................................ 11 11 12 12 13 15 15 16 17 17 Startup and Familiarization ............................................................................................ 19 Quick Start Procedure ....................................................................................................... 19 iii MI 611-185 – June 1996 Contents Display Menus ............................................................................................................... Main Menu Structure ....................................................................................................... Control Menu ................................................................................................................... Setup Procedure ................................................................................................................ Passcode Protection ........................................................................................................... Calibration ........................................................................................................................ Scenario 1 ..................................................................................................................... Scenario 2 ..................................................................................................................... Scenario 3 ..................................................................................................................... Calibration Configuration ............................................................................................ Detector Counts ........................................................................................................... Defining the Span Gas Concentration(s) ...................................................................... Defining the Response Factor ....................................................................................... Alarm Levels ................................................................................................................. Log Methods ................................................................................................................ Hardware Configuration (Barcode Reader/Probe Display) ................................................ User Identification Number ......................................................................................... Date ............................................................................................................................. Time of Day ................................................................................................................. User Options ................................................................................................................ Information Menu ............................................................................................................ PC Link/Memory ......................................................................................................... Run Mode ......................................................................................................................... Accessing the Run Menu .............................................................................................. Using the Enhanced Probe ................................................................................................ The Enhanced Probe and the RUN Mode .................................................................... Auto Logging with the Enhanced Probe ....................................................................... VOC Logging with the Enhanced Probe ...................................................................... FE (Fugitive Emissions) Logging with the Enhanced Probe .......................................... Additional Component Information ............................................................................. 21 21 24 24 25 25 25 26 26 27 29 30 31 36 39 45 46 46 47 47 48 48 55 56 58 58 59 59 59 62 Maintenance................................................................................................................... Removable, Renewable Parts ............................................................................................. Normal Operating Maintenance ....................................................................................... Battery and Battery Charger ......................................................................................... Hydrogen Gas Tank ..................................................................................................... Servicing the PID Cartridge ......................................................................................... Servicing an FID Cartridge ........................................................................................... Cleaning the FID Detector Cap ................................................................................... Replacing the Flame Arrestor ........................................................................................ Cleaning the FID or PID Detector Cavities .................................................................. Cleaning or Replacing a Sintered Metal Filter ............................................................... Replacing Sample Line ................................................................................................. 63 63 64 64 65 66 67 68 68 69 69 70 iv Contents MI 611-185 – June 1996 Troubleshooting............................................................................................................. 73 Warning Messages ............................................................................................................. 76 Accessories...................................................................................................................... 79 Telescoping Extension Option ..................................................................................... 79 Activated Charcoal Filter Adapter ................................................................................. 79 Appendix A: Text Data Formats..................................................................................... Route List File Format ...................................................................................................... Sample Route List File ...................................................................................................... Configuration File Format ................................................................................................ Sample Configuration File ................................................................................................ Calibration File Format ..................................................................................................... Sample Calibration File (Dual Detectors) ......................................................................... Logged Data File Format (Upload Only) .......................................................................... Sample Logged Data File (FE format) ............................................................................... Sample Logged Data Files ................................................................................................. 81 81 82 82 83 84 85 85 86 87 Index .............................................................................................................................. 93 v MI 611-185 – June 1996 vi Contents Figures 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Analyzer Sidepack ........................................................................................................ 1 Typical Flame Ionization Detector ............................................................................... 7 Typical Photoionization Detector ................................................................................ 9 TVA-1000B Dual Detector Configuration ................................................................ 10 TVA-1000B Instrument Connections ........................................................................ 11 Keypad ....................................................................................................................... 14 Sample Probe Assembly .............................................................................................. 15 TVA-1000B BASIC Probe Display ............................................................................ 16 TVA-1000B Enhanced Probe Display - Menu Mode ................................................. 17 PID Lamp Cleaning Kit ............................................................................................. 67 Sintered Metal Filter - Cleaning or Replacing ............................................................ 70 Replacing Sample Line ............................................................................................... 71 Telescoping Extension Option ................................................................................... 79 Activated Charcoal Filter Adapter .............................................................................. 80 vii MI 611-185 – June 1996 Tables Tables 1 2 3 viii Specifications ............................................................................................................... 3 External Influences ....................................................................................................... 6 Product Safety Specifications ........................................................................................ 6 Introduction NOTE: References in this manual to BASIC and enhanced probes do not apply to Leak Tracker users. Overview The TVA-1000B Toxic Vapor Analyzer, illustrated in the figure below, is an advanced-design, portable, organic/inorganic vapor monitor for the gas survey industry. This analyzer uses either a flame ionization detector (FID), or a photoionization detector (PID), or both types of detectors to sample and measure concentration of gases. The vapor concentration may be read immediately on either of two displays — one mounted directly on the hand-held sample probe and the other on the instrument sidepack itself. Vapor concentration can be displayed on both displays in parts per million (ppm), parts per billion (ppb), or percent concentration (%). The data displayed may also be collected and saved in analyzer memory and downloaded to a personal computer for analysis. Through the sidepack keyboard, you can choose the mode of operation, select concentration units for the display, set alarm thresholds, select data collection mode, and change setup (configuration) parameters. This unit is shipped with the battery installed. The unit is ready for operation upon completion of setup, calibration, and charging. TVA-1000B ABC ABC 1 1 ABC ABC ABC 1 1 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 ABC 1 Figure 1. Analyzer Sidepack 1 MI 611-185 – June 1996 Introduction Instrument Functions This analyzer functions in any of four modes: ♦ RUN ♦ SETUP ♦ INFO ♦ PC LINK/MEMORY In the RUN mode, the instrument automatically displays its measured values in units of ppm, ppb, or %. The RUN mode may be operated either as survey only, in which the instrument displays measured values but does not store any data, or survey and log, in which the instrument displays measured values and also stores the information in memory. In SETUP mode, you can enter or select operational parameters, such as calibration values, alarm levels, operator ID, datalogging method and interval, date, and time. This may be performed locally by using the analyzer keypad or remotely by using the RS-232 connection to a personal computer (PC). In INFO mode, you can review operational parameters entered or selected in SETUP mode as well as instrument serial number, battery status, etc. In PC LINK/MEMORY mode, you can download data stored within the TVA-1000B to a PC for analysis and printing, upload route list, calibration, and configuration parameters from a PC to the TVA-1000B, or clear data memory. Each of the four modes is explained in detail later in this document. Using the Instrument While operating this instrument in the field, you normally carry the TVA-1000B at your side, using the shoulder strap. With the pump on, detector(s) on, and the unit warmed up, you monitor the area of concern. As soon as the instrument analyzes a sample, the probe displays concentration of the vapor. The display on the sidepack duplicates the vapor concentration on the probe display. Using the BASIC probe, you can toggle the display between detector types by pressing the DET button on the probe, log the survey data by pressing the LOG button, and backlight the LCD display by pressing the lamp button. An optional enhanced probe for Fugitive Emissions (FE) monitoring applications allows you to select options from special menus. These probe types will be detailed later in this document. WARNING: Do not connect/disconnect any electrical device (such as battery charger, analog output, personal computer, or auxiliary port device) to the instrument in an area classified as hazardous due to the presence of flammable vapors. 2 Introduction MI 611-185 – June 1996 Standard Specifications Table 1. Specifications Item Accuracy Repeatability Analog Output Dynamic Range Linear Range Minimum Detectable Level Response Time using close area sampler Recovery Time using close area sampler Response Time using telescoping wand extender Recovery Time using telescoping wand extender Specification PID Instrument — ±25% of reading or ±2.5 ppm, whichever is greater, from 0.5 to 500 ppm. Accuracy listed is achieved using isobutylene with a 1-point calibration in the range from 100 to 300 ppm (including drift) at the temperature and humidity of the calibration. FID Instrument —±25% of reading or ±2.5 ppm, whichever is greater, from 1.0 to 10,000 ppm. Accuracy listed is achieved using methane with a 1-point calibration in the range from 100 to 500 ppm (including drift) at the temperature and humidity of the calibration. PID Instrument — ±1% at 100 ppm of isobutylene FID Instrument — ±2% at 100 ppm of methane Two analog output signals, 0 to 2 V dc, proportional to the count output from each detector. PID Instrument — 0.5 to 2,000 ppm of isobutylene FID Instrument — 1.0 to 50,000 ppm of methane PID Instrument — 0.5 to 500 ppm of isobutylene FID Instrument —1.0 to 10,000 ppm of methane The minimum detectable level is defined as two times the peak-topeak noise. PID Instrument — 100 ppb of benzene FID Instrument — 300 ppb of hexane PID Instrument — Less than 3.5 seconds for 90% of final value, using 100 ppm of isobutylene FID Instrument — Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane PID Instrument — Less than 5.0 seconds to return to 10% of base line, using 100 ppm of isobutylene FID Instrument — Less than 5.0 seconds to return to 10% of base line, using 10,000 ppm of methane PID Instrument — Less than 5.0 seconds for 90% of final value, using 100 ppm of isobutylene FID Instrument — Less than 5.0 seconds for 90% of final value, using 10,000 ppm of methane PID Instrument — Less than 5.0 seconds to return to 10% of base line, using 100 ppm of isobutylene FID Instrument — Less than 5.0 seconds to return to 10% of base line, using 10,000 ppm of methane 3 MI 611-185 – June 1996 Introduction Table 1. Specifications (Continued) Item Response Time using charcoal filter adapter Recovery Time using charcoal filter adapter Data Storage Interval Sample Flow Rate Battery Battery Charger PID Lamp Life FID Life Audio Output Level Gas Cylinder Capacity Hydrogen Supply Operating Time Enclosure Description 4 Specification PID Instrument — Less than 20 seconds for 90% of final value, using 100 ppm of isobutylene FID Instrument — Less than 20 seconds for 90% of final value, using 10,000 ppm of methane PID Instrument — Less than 20 seconds to return to 10% of original value, using 100 ppm of isobutylene FID Instrument — Less than 20 seconds to return to 10% of original value, using 10,000 ppm of methane Auto Mode — 1 per second to 1 per 999 minutes, user selectable VOC or FE Mode — 2 to 30 seconds, user-selectable 1 liter/minute, nominal, at sample probe inlet The battery can be fully charged in less than 16 hours. The battery operating time is 8 hours minimum at 20° (32°F). Use of the backlight on the probe display shortens battery life. The battery is replaceable by removing the bottom cover of the instrument. (WARNING: Do not replace battery in an area classified as hazardous due to presence of flammable gases or vapors.) The battery charger is a separate unit capable of operating the analyzer while simultaneously charging the internal battery. An adapter cable is provided to charge the battery separate from the analyzer. The charger can charge a fully discharged battery in a maximum of 16 hours. Charging takes longer if performed while the instrument is operating. Two types of chargers are available, one for 120 V ac, 50/60 Hz and another for 230 V ac, 50/60 Hz. (WARNING: Do not operate battery charger in an area classified as hazardous due to presence of flammable gases or vapors.) Greater than 2000 hours for 10.6 eV lamp, with normal cleaning Greater than 2000 hours Greater than 75 dB at 3 feet Pressure — 15.3 MPa at 25°C (2200 psi at 77°F) maximum Empty — 85 cc (5.19in3) Greater than 8 hours of continuous operation, starting from a cylinder charged up to 15.3 MPa (2200 psi) The analyzer enclosure and front panel are made from a chemically resistant thermoplastic material. The approximate dimensions are 343 x 262 x 81mm (13.5 x 10.3 x 3.2 in). The enclosure is designed to provide environmental protection. Introduction MI 611-185 – June 1996 Table 1. Specifications (Continued) Item Specification Electrical Interface Connections Mating female connectors for Analog Output, RS-232 Interface (Host), and Battery Charger are provided on the side of the analyzer case below the keypad. Mechanical Connections Mechanical connections for Sample Input and for Vent Outlet are provided on the side and bottom surfaces. Portability The analyzer is designed to be carried by a removable shoulder strap. The strap, which is provided with every instrument, does not hinder the user when viewing or using the analyzer front panel. The strap is designed to support the probe when the instrument is not in use and to carry accessory tools. Tool Kit An accessory tool kit is provided with each instrument. The kit contains special tools for accessing the battery and removing the detector capsules. Approximate Mass Analyzer (PID plus FID): PID only —4.8 kg (10.5 lb) FID only —4.8 kg (10.5 lb) Dual — 5.2 kg (11.9 lb) Probe Assembly: Standard Probe — 0.55 kg (1.1 lb) Enhanced Probe —0.79 kg (1.75 lb) External Influences This product is intended for use in indoor and outdoor environments as a portable instrument carried by a user, as specified in the following table. The same environmental conditions also apply to the sample stream being monitored. 5 MI 611-185 – June 1996 Introduction l Table 2. External Influences External Influence Ambient Temperature Ambient Pressure Relative Humidity Radiated Susceptibility Conducted Susceptibility Conducted Emission Radiated Emission ESD Sensitivity Battery Charger Supply Voltage Battery Charger Supply Frequency Reference Operating Conditions 23±2 °C 73±2 °F 860 to 1060 mbar 50%±10% None Normal Operating Conditions 0 to +40°C 32 to 104 °F 70 to 108 kPa FID: 20 to 95% PID: 20 to 70% noncondensing Operative Limits 0 and +50°C 32 and 122 °F 15 and 95% noncondensing Transportation and Storage Limits -20 to +60°C -4 and 140 °F 20 to 108 kPa 0 to 100% 30 V/m 27 to 500 MHz Not Applicable, Battery Operated Not Applicable, Battery Operated 80 dBµV 0.15 to 30 MHz >6000 Volts 120 or 230 ±1% Vac 50/60 Hz ±0.5 Hz 120 or 230 +15%, -10% V ac 47 to 63 Hz Not Applicable 47 and 63 Hz Not Applicable Product Safety Specifications Table 3. Product Safety Specifications Testing Laboratory, Types of Protection, and Area Classification FM: intrinsically safe for Class I, Division 1, Groups A, B, C, and D *CENELEC: intrinsically safe for Zone 1 and Zone 2, (EEx ib d IIC) *CSA: intrinsically safe for Class I, Division 1, Groups A, B, C, and D. Conditions of Classification Temperature Class T4 Electrical Classification Code FAZ Temperature Class T4 EBZ Temperature Class T4 CAZ *Not available at release. Contact Thermo Environmental Instruments for current status. 6 Theory of Operation Flame Ionization Detection (FID) A Flame Ionization Detector (FID) measures organic compounds by utilizing a flame produced by the combustion of hydrogen and air. When hydrocarbons in the sample are introduced to the detection zone, ions are produced by the following reaction: where RH + O → RHO+ + e– → H2O + CO2 R = carbon compound A collector electrode with a polarizing voltage is also located within the detector chamber, and the ions produced by this reaction are attracted to it. As the ions migrate towards the collector, a current is produced which is directly proportional to the concentration of hydrocarbons introduced to the flame. This current is then amplified and sent to a microprocessor and/or analog readout device. The FID has a wide dynamic range. The effective dynamic range can be further expanded by use of a dilutor kit which reduces very high volatile organic compounds (VOC) concentrations to within the dynamic range (or even linear range) of the analyzer. The dilutor kit can also be used to enrich oxygen deficient samples by adding ambient air that is rich in oxygen (20.9% usually). Low oxygen can affect the characteristics of the hydrogen flame, causing readings to be artificially elevated and possibly extinguishing the flame. As a general rule of thumb, greater than 16% oxygen is required to support the flame. If underground gases or samples in gas bags are to be measured by an FID, it is advised that the dilutor be used to combat the problem. EXHAUST METER IGNITION FILAMENT COLLECTOR ELECTRODE JET AIR SAMPLE FUEL (H2) Figure 2. Typical Flame Ionization Detector 7 MI 611-185 – June 1996 Theory of Operation Benefits of Flame Ionization Detection ♦ ♦ ♦ ♦ Wide dynamic and linear range High sensitivity to hydrocarbon vapors (including methane) Very stable and repeatable response Virtually unaffected by ambient levels of CO, CO2, and water vapor Photoionization Detection A Photoionization Detector (PID) consists of an ultraviolet (UV) lamp of a specific energy and an ionization chamber. Compounds passing through the chamber are excited by photons of UV energy and ionized according to the following equation: R + hυ → R+ + e– where R = most organic/inorganic compounds These ions are attracted to a collecting electrode, producing a current proportional to the concentration of the compound. Whether or not a compound can be detected by a PID depends upon the energy required to remove an electron from the compound (its ionization potential). If the lamp energy is greater than the compound’s ionization potential, the PID will detect it. The standard lamp in the TVA-1000B is 10.6 eV. Other lamps (9.6 and 11.8 eV) are also available. The 11.8 eV lamp permits detection of many compounds not ionized by the standard lamp. The lower energy (10 eV) lamps, however, allow more selectivity by not responding to undesired compounds with a higher ionization potential. NOTE: Refer to MI 611-183 for information and guidance on proper use of the 11.8 eV lamp. Because of its smaller dynamic range (0-2000 ppm), the PID is not the detector of choice for measuring high concentrations of vapors. A PID is also more susceptible to interference from water vapor than a FID. However, as a PID does not require hydrogen or oxygen, it is the detector of choice when fuel is limited or unavailable, or when ambient oxygen concentrations are low. The PID is also very sensitive to aromatic and chlorinated compounds, and can even measure some inorganic compounds that the FID does not detect at all (ammonia, carbon disulfide, carbon tetrachloride, chloroform, ethylamine, formaldehyde, and hydrogen sulfide, to name a few). Benefits of Photoionization Detection ♦ ♦ ♦ ♦ ♦ 8 High sensitivity to aromatics, unsaturated hydrocarbons and chlorinated hydrocarbons Ability to measure some inorganic gases Very simple operation No support gases required Non-destructive detector allows sample to be recovered Theory of Operation MI 611-185 – June 1996 UV SOURCE LAMP IONIZATION CHAMBER WINDOW METER SAMPLE OUT SAMPLE IN COLLECTING ELECTRODE Figure 3. Typical Photoionization Detector Dual Detectors The benefits of each individual detector are very clear: both the FID and the PID have their advantages and disadvantages. However, with either detector alone, the number of organic and inorganic vapors that one can detect is limited by the measurement capabilities of that detector. With the TVA-1000B, users can obtain complete information about more organic and inorganic vapors more quickly and easily than with single detector technology alone. Since both detectors may be displayed and logged simultaneously, the relative response of the two detectors may give some clues about the identity of the compound being measured. For instance, the PID does not respond to methane at all, but the FID responds very well. A high FID reading with virtually no PID response might indicate the presence of methane. Consequently, PIDs respond very well to some inorganic gases that FIDs cannot detect. A high PID reading with no FID reading might suggest the presence of an inorganic compound. With readings from both detectors readily available, the TVA-1000B can help a user make decisions about the type of compound present and which detector reading to use. Benefits of Dual Detectors ♦ ♦ ♦ Cost-effective packaging Detector response ratios can help characterize compounds Enhanced analytical capability derived from simultaneous detection 9 MI 611-185 – June 1996 Theory of Operation PID 00000 PPM FID 00000 PPM % AMPLIFIER METER EXHAUST FLAME ARRESTOR FID TVA-1000B COLLECTOR ELECTRODE PID IGNITION FILAMENT JET LAMP VENT AIR SAMPLE OUT COLLECTOR ELECTRODE AIR SAMPLE IN AIR SAMPLE IN HYDROGEN SUPPLY Figure 4. TVA-1000B Dual Detector Configuration Concentration Calculation and Calibration The concentration calculation is defined as the process that transforms a detector count into a displayed final concentration. The process is as follows: DETECTOR COUNT TRANSLATED INTO A STANDARD DETECTOR CONCENTRATION USING A DETECTOR COUNT VS. DETECTOR CONCENTRATION CALIBRATION CURVE. STANDARD DETECTOR CONCENTRATION IS CORRECTED TO A SPECIFIC GAS USING THE INSTRUMENT RESPONSE FACTOR. SPECIFIC GAS CONCENTRATION IS BACKGROUND CORRECTED (IF ENABLED) INSTRUMENT RESPONSE FACTOR AND BACKGROUND CORRECTED CONCENTRATION IS RF CORRECTED USING THE CURRENT ROUTE ENTRY RF (IF ANY) FINAL CONCENTRATION READING 10 Hardware NOTE: A TVA-1000B may be configured in any of several different packaging arrangements. The configuration described in this document is for the BASIC probe and carrying case. Instrument Connections There are six external instrument connections on the TVA-1000B, as shown in the figure below. The umbilical attached to the probe consists of two connections, an electrical cable with locking connector and a sample line with locking fitting. A connector for a serial tag reader (i.e., a laser barcode reader) is located next to the hydrogen on/off valve. These three connections are located on the side of unit above the display. Three additional connections — analog output, battery charger input, and RS-232 interface — are located on the opposite side of the unit, below the keypad. All mechanical connections are keyed for easy orientation. HYDROGEN ON/OFF VALVE ELECTRIC AND PNEUMATIC CABLES FROM SAMPLE PROBE CONNECT HERE SERIAL TAG READER CONNECTOR HYDROGEN GAS TANK WITH INTEGRAL GAUGE OUTPUT GAUGE FOR HYDROGEN PRESSURE REGULATOR SAMPLE VENT ALARM SOUNDER PID DETECTOR (REMOVABLE CARTRIDGE) FID DETECTOR (REMOVABLE CARTRIDGE) KEYPAD AND DISPLAY SHOULDER STRAP CONNECTS TO RINGS (2) ANALOG OUTPUT (OUT) BATTERY CHARGER (CHRG) RS-232 INTERFACE (HOST) Figure 5. TVA-1000B Instrument Connections WARNING: To prevent a potential explosion, never connect or disconnect any devices to the analog output, battery charger, or RS-232 interface ports in an area classified as hazardous due to presence of flammable gases or vapors. 11 MI 611-185 – June 1996 Hardware WARNING: To prevent a potential explosion, do not operate the instrument with the PID or FID detector caps removed. Analog Outputs The TVA-1000B has two analog output signals, one for each detector (FID and PID). The analog output cable has a single plug at the instrument end and four individual banana plugs at the output end. The orange plug is the FID output, the blue plug is the PID output. The two black plugs are connected to a common ground. It is important to note that these outputs are non-calibrated outputs which are proportional to the raw count output signal from each detector. The outputs are not proportional to the PID and FID dynamic ranges of 0-2000 and 0-50000 ppm. To calibrate these outputs, it is necessary to measure the output voltage at the time of gas calibration. When zero gas is introduced to the unit, measure the output voltage for each detector (this is the zero output voltage). When the span gas is introduced to the unit, measure the output voltage for each detector (this is the span output voltage). The output voltage for any other concentration can be calculated with the following formula: Vx = Vo + Cx [(Vs -Vo)/(Cs)] where: Vx = Output voltage at the concentration of interest Cx = Concentration of interest Vs = Span output voltage Cs = Span concentration Vo = Zero output voltage Instrument Sidepack Display The liquid crystal display (LCD), in the instrument sidepack, as shown in the figure that follows, has four 16-character lines for three types of displays (MENU, ENTRY, and RUN). In menu displays, the whole screen is normally dedicated to the menu. In entry displays, the screen provides prompts and instructions for inputting new data. The normal run display consists of the live measurement data on lines 1 and 2 and menu items on lines 3 and 4. Other display information appears as you page through various menus. 12 Hardware In menu displays, the whole screen is normally dedicated to the menu. MI 611-185 – June 1996 MAIN MENU 1 RUN== 2 SETUP 3 INFO 4 PCLINK/MEMORY MENU DISPLAY In entry displays, the screen provides prompts and instructions for entering new data. ENTER LOW CEIL: FID: = 000.00 PPM UP/DN NEXT UNIT ENTER ACCEPT ENTRY DISPLAY The normal run display consists of the live measurement data in Lines 1 and 2 and menu items on lines 3 and 4. PID: 0.50 PPM FID: = 2.50 PPM TAG: BLD _ PRESS CHAR KEY Other display information appears as you page through various menus. RUN DISPLAY Instrument Sidepack Keypad The keypad, as shown on the following page, has 19 keys, some of which are dual function. When you press a key, the screen displays the selection. When you make a selection that creates or changes a parameter, you must then press the ENTER key. The left/right arrow keys move the character entry position. The up/down keys make page selections or switch from ppm, ppb, or % to another reading. The following figure and table show the functions of all keys. 13 MI 611-185 – June 1996 Hardware TVA-1000 CONTROL 8888888888888888 8888888888888888 8888888888888888 8888888888888888 ABC DEF GHI 1 2 3 JKL MNO PQR 4 5 6 YZ SP ON STU VWX 7 8 OFF EXIT 0 9 ENTER Figure 6. Keypad NOTE: To activate OFF, CONTROL, EXIT, and ENTER functions, press and HOLD the key for approximately 1/2 second. Key ON OFF CONTROL EXIT ENTER Function The ON key enables power from the battery to the instrument. The OFF key disables power from the battery to the instrument. The CONTROL key is multi-function and is used to turn the pump, PID, and FID on or off, and to ignite the FID. The EXIT key clears any entry made in error or bypasses information that you do not want to change, and clears error or warning screens. The ENTER key has three functions: 1. Press ENTER if you have typed one or more characters and wish to keep that information. 2. Press ENTER to respond to a menu question. Left/Right Arrows Up/Down Arrows 14 3. Press ENTER instead of the LOG key on the standard probe to initiate logging. The left and right arrow keys move character entry positions. The up and down arrow keys make page selections or scroll through options in SETUP entry screens. Hardware MI 611-185 – June 1996 Key Function Alphanumeric The alphanumeric keys enable you to type letters or numbers into various menus. If a display asks for a number only, simply press the desired key. Two steps are required to type an alphanumeric character. First, press the key with the desired letter or number. The screen then displays a selection prompt at the bottom in which 1 = first letter, 2 = second letter, 3 = third letter, and 0 = number. Press the appropriate key to execute the selection. Three uses: ♦ Select menu options ♦ Enter numbers, 0-9, using single keystroke ♦ Enter alphanumeric data, A-Z, 0-9, SPACE, using 2 keystrokes per character Probe Connections The sample probe assembly is a hand-held device that enables you to take vapor samples at precise locations. It connects to the instrument by means of an umbilical. The umbilical has two quick-disconnect fasteners (one electrical, one sample line) at the instrument end. Use the slide-on connector, located at the forward end of the probe, to attach various sampling devices. The operator keypad and measurement display are also located on the handle, as shown in the following diagram. PROBE NUT AND SLEEVE CLOSE AREA SAMPLING ASSEMBLY PROBE KEYPAD AND DISPLAY THE CLOSE AREA SAMPLER (*CHARCOAL FILTER OR WATER TRAP) CAN BE PLACED DIRECTLY INTO THE READOUT UNIT OR EXTENDED BY USING THE OPTIONAL TELESCOPING WAND. *OPTIONAL Figure 7. Sample Probe Assembly BASIC Probe Display The BASIC sample probe has a 4-character LCD display, as shown below, that displays measurement information. The display also contains an overrange indication, expressed as “>” when active. Three measurement unit types — ppm, ppb, or % — (selected during setup) are displayed to the right of the measurement data. Only those units selected during setup, however, are visible during survey. 15 MI 611-185 – June 1996 Hardware A segmented analog bargraph that represents a logarithmic scale for the total analyzer range appears below the digital display. This display, which may be backlit under low light conditions, is active only in the RUN mode. In all other modes, it displays OFF. The measured value display area is used to flash logging prompts during survey and log mode. In addition, errors on the sidepack are indicated by “Err” on the probe. Errors are cleared by using the LOG key. MEASURED VALUE AND ERROR/LOGGING PROMPTS MEASUREMENT UNITS DETECTOR BEING DISPLAYED 8.8.8.8. fid DET DETECTOR SELECTOR BUTTON pid % ppm ppb > >> OVERRANGE INDICATOR LOGARITHMIC BARGRAPH LOG LOG SELECTOR BUTTON BUTTON FOR DISPLAY BACKLIGHTING Figure 8. TVA-1000B BASIC Probe Display NOTE: Use of the backlight draws additional power from the battery and will shorten the runtime of the TVA-1000B. BASIC Probe Keys The BASIC probe keypad has three keys. The keys are labeled with DET, LOG, and a lamp symbol. Key DET Function Press and release this key to select the display of either the FID or the PID readings in the RUN mode. Press and hold this key (approx. 2 seconds) to cancel selected logging modes. Press and release this key to start the datalogging feature. Survey information is LOG then automatically stored in the analyzer memory. The selection in SETUP/Log must be AUTO or VOC. Press and release this key to clear a sidepack error when the display reads “ Err”. Lamp Symbol Press this key to turn the backlight for the probe display on or off. You should use it only during low light conditions as it draws additional power from the battery and thus shortens instrument run time. 16 Hardware MI 611-185 – June 1996 Enhanced Probe Display The enhanced probe also has an LCD screen which displays the basic measurement information. Unlike the BASIC probe, the enhanced probe display is larger (8 line x 20 character display) and is capable of providing several menu-driven functions. These MENU selections allow the user to start a datalogging application, switch detectors, ignite the FID, and perform a background scan. In Fugitive Emissions monitoring applications, the MENU selections also allow the user to step through a tag route, search for a selected tag, start a logging event, log repair data, etc. The display, which may be backlit under low light conditions, is active only in the RUN mode. In all other modes, the display is OFF. MEASURED VALUE OVERRANGE INDICATOR TVA-1000B DETECTOR BEING DISPLAYED fid pid 8.8.8.8. >> XXX MEASUREMENT UNITS (%, PPM, PPB) SEGMENTED BARGRAPH >> < >> MENU PROBE MENU DISPLAY BUTTON < > > <<< CLR MENU>> SELECT MENU SELECTOR BUTTON BUTTON FOR DISPLAY BACKLIGHTING Figure 9. TVA-1000B Enhanced Probe Display - Menu Mode NOTE: Use of the backlight draws additional power from the battery and will shorten the runtime of the TVA-1000B. Enhanced Probe Keys The enhanced probe has three keys, labeled MENU, SELECT, and a lamp Symbol. MENU and SELECT are multi-functional. Key Function MENU Press and release this key to show the probe display menu or to move to the next menu option. Press and hold this key (approx. 2 seconds) to toggle the info screen on/off. SELECT Press and release this key to select the highlighted menu option. Lamp Symbol Press this key to turn the backlight for the probe on or off. As it draws additional power from the battery and thus shortens instrument run time, use it only during low light conditions. 17 MI 611-185 – June 1996 18 Hardware Startup and Familiarization This section shows you how to start the instrument and become familiar with the keypad and display by demonstrating the top level menu structure. To begin, connect the sample probe (electrical and sample line connections) to the appropriate receptacles on the TVA-1000B, calibrate the instrument per the procedure beginning on page 25, and then follow the procedure described on the next page. NOTE: If the unit is on but not yet set up/configured, it uses factory default values. To make the instrument function with your specific parameters, follow the setup procedures described under Display Menus in this manual. The procedure below is a quick start guide for starting up your unit. We strongly recommend that you read the entire manual before using the analyzer for its intended operations. Quick Start Procedure Before starting the unit, perform the following steps: 1. Charge battery. 2. Connect sample probe. 3. Fill/install hydrogen tank (FID versions). 4. Open the hydrogen valve (FID versions). To start the unit, execute the following procedure: 1. Press ON. 2. Press CONTROL. 3. Press 3 to ignite. 4. Press 2 = Setup. 5. Press 1 = Calibrate 6. Press 2 = Span Concentration. 7. Enter Span Concentration for calibration gas being used. NOTE: If PID only, enter concentration of isobutylene. If FID only, enter concentration of methane. If dual, enter concentration of both gases. 8. Press 3 = Zero. 9. Press 1 = Both. 10. Challenge analyzer with zero gas sample. 11. Press ENTER = start. 19 MI 611-185 – June 1996 Startup and Familiarization 12. Wait to stabilize. 13. Press ENTER = start. 14. Press 4 = Span 15. (PID 1st) Press 2 = PID. 16. Press ENTER = start. 17. Challenge analyzer with isobutylene span gas and wait for readings to stabilize. 18. Press ENTER to accept. 19. Press 4 = Span. 20. Press 3 = FID. 21. Press ENTER = Start. 22. Challenge analyzer with methane span gas and wait for readings to stabilize. 23. Press ENTER = Accept. 24. Press 5 = Response Factor. 25. Confirm that Response Factor says “RF0:DEFAULT” 26. Press EXIT 2 times to main menu. 27. Press 1 = Run. You are now in the survey mode. NOTE: To perform more sophisticated operations, you will need to read the rest of the manual . To power down this instrument, simply press and hold the OFF key. With FID versions, you must also shut off the gas valve to avoid depleting the tank supply. 20 Display Menus Main Menu Structure The display on the TVA-1000B analyzer is a menu-driven device. The various menus prompt you to select or enter information. With various key strokes, you can accomplish all necessary setup (configuration) and operational tasks. Whenever you turn on the TVA-1000B, the Main menu screen display is the first usable display to appear. It contains selections that move you to all other menus. When you press the appropriate number key, as described below, the desired menu and the associated display or menu appear automatically. Menu Selection 1 = RUN 2 = SETUP 3 = INFO 4 = PCLink/Memory MAIN MENU 1=Run 2=Setup 3=Info 4=PCLink/Memory Function Use this selection to assign tags to specific surveys and to view/log analysis of organic/inorganic compounds This menu contains configuration procedures and menu structure for performing calibrations, entering ID numbers, setting alarm levels, selecting log modes, entering response multipliers and setting time/date. This is a view-only menu structure that allows you to display various information. Use this menu to download/upload information to/from a personal computer, to perform a remote SETUP from a personal computer, or to clear memory. Once you are familiar with the various menus and know where to enter specific information, you may want to use a short cut method of tracking the menu structure. The following figure shows the complete menu structure for the TVA-1000B Analyzer. Warning messages and meanings can be found in the Troubleshooting section of this manual (see “Warning Messages” on page 76). 21 MI 611-185 – June 1996 1 RUN 22 Display Menus 2 SETUP (Passcode Protected) CALIBRATION CONFIG NUMBER SPAN POINTS BACKGROUND CORRECT ACCEPT MODE SAVE MODE RF CALC MODE SPANCONC (Enter Span Gas Conc.) ZERO (CALIB) SPAN (CALIB) RESPONSE FACTOR CHANGE NAME VALUE ACCEPT BACKGROUND (CONC UPDATE) ALARMS STEL LOW CEILING HIGH CEILING LOG NONE AUTO VOC/FE VOC FE CUSTOM PASSCODE NEW PASSCODE ENABLE DISABLE HARDWARE PROBE DISPLAY BASIC ENHANCED BARCODE READER SELECT READER NONE HP SMART WAND PSC LASER INITIALIZE READER OTHER USER ID DATE TIME USER OPTIONS KEY CLICK DISPLAY DELAY 3 INFO 4 PCLINK/MEMORY PC LINK CHANGE TYPE ESTABLISH LINK CLEAR ROUTE & LOGGING MEMORY Display Menus MI 611-185 – June 1996 Control Menu The Control menu is used for turning the sampling pump on and off, turning the PID lamp and FID on and off, and for initiating gas ignition of FID. The menu has four options: 1 = Turn Pump ON/OFF 2 = Turn FID ON/OFF 3 = Ignite FID 4 = Turn PID OFF/ON Selecting Option 1 toggles the pump on or off. Selecting Option 2 toggles the FID on or off. In the RUN mode, when the FID is off, dashes will appear instead of a reading and all FID alarms are overridden. Selecting Option 3 initiates the FID flame ignition sequence, which momentarily turns on the ignite coil and simultaneously turns off the pump. Selecting Option 4 toggles the PID on or off. In the RUN mode, when the PID is off, dashes will appear instead of a reading, and all PID alarms are overridden. After running the initial startup diagnostic, the Control menu can be accessed at any time. Setup Procedure Setup (configuration) of the TVA-1000B is the most important step in obtaining accurate gas samples. During setup, you must set four parameters, as follows: 1. Calibration Settings 2. Alarm Levels 3. Date (year/month/day) (Set once only.) 4. Time of Day (Set once only.) NOTE: Time may be set only if the date is within the valid range of 1980 to 2037. You may also set the following parameters: 1. Log Methods 2. Type of Probe Display or Barcode Reader 3. Compound Names and Response Factors 4. Reader Type and Port Initialization (if used) 5. User Identification Number 6. Optional Settings (Calibration Passcode, Key Click, Display Delay, Calibration Mode) Each parameter is explained in detail in the following. 23 MI 611-185 – June 1996 Display Menus Passcode Protection The TVA-1000B Setup Menu can be passcode protected. This option allows you to protect the setup parameters from anyone who is not familiar with your 6-digit passcode. If this feature is enabled, you need to enter your passcode each time you choose to display the SETUP menu. A selection in the SETUP menu entitled “Passcode” allows you to administer the passcode protection feature. From the SETUP menu, choose option #4 (Passcode). The TVA-1000B will give you three choices: 1. New Passcode This selection allows you to enter and/or change the 6-digit calibration passcode. You may use any characters from the alphanumeric keypad in your passcode. You must then verify the passcode to make sure you have entered it properly. 2. Enable This selection allows you to activate the passcode protection feature. Once this feature is activated, you must enter your passcode whenever you request access to the SETUP menu. Once passcode protection has been enabled and you exit the SETUP menu, the option can only be disabled by entering the passcode to gain access to the SETUP menu again. REMEMBER YOUR PASSCODE! 3. Disable This selection allows you to deactivate the passcode protection feature. Once this feature is deactivated, you have unlimited access to the SETUP menu without entering a passcode. NOTE: In the event you inadvertently forget your passcode, contact TEI for assistance. Calibration The use of multipoint calibration and multiple response factors/curves with the TVA-1000B must be fully understood before employing these features. To help explain these TVA-1000B capabilities, three scenarios follow: Scenario 1 To maximize standard accuracy, it is highly recommended that you calibrate with methane for the flame ionization detector and isobutylene for the photoionization detector. Almost all published response factors for FIDs and PIDs are based upon methane and isobutylene, respectively. By employing a multipoint calibration for these compounds, you will improve the accuracy of each detector over the entire dynamic range. Response factors/curves can then be employed for correcting the detector’s response to different compounds. However, once a multipoint calibration has been employed, any response curve must characterize only the relative response at each concentration, excluding curvature of the calibrated compound. Thus , use of both multipoint calibration and response curves at the same time is difficult, and is not recommended. 24 Display Menus MI 611-185 – June 1996 Scenario 2 If, for example, you want to measure several different compounds over wide concentration ranges, it is best to use a single-point calibration and then enter response curves for each specific compound (up to 9 response factors/curves can be entered into the analyzer). Scenario 3 If, instead, you want to measure in direct readings (response factor = 1) for one specific compound with maximum accuracy over a wide range of concentrations, perform a multipoint calibration with the specific compound. Up to 9 span points (plus zero) can be entered for each detector. The use of a response curve is thus unnecessary as the detector is already reading the direct PPM for that specific compound. CAUTION: If you use multipoint calibration or a gas other than methane or isobutylene and then apply response factors/curves (that have been generated with reference to a single point methane/isobutylene calibration), the resulting measurements will probably be incorrect. To provide the specified accuracy, the instrument must be calibrated at the beginning of each workday. To reach the CALIBRATION menu from the MAIN MENU, choose 2 = Setup and 1 = Calib. When you reach the CALIBRATION menu, you will see the following selections: Calibration MENU 1=Cfg 2=SpanConc 3=Zero 4=Span 5=RF 6=Backgnd The steps involved in calibrating the TVA-1000B are as follows: 1. Configure the calibration variables (Cfg). 2. Define the span concentrations to be used (SpanConc). 3. Zero the instrument using either a zero gas or clean ambient air (Zero). 4. Calibrate the reference point(s) using known span gases. The TVA-1000B can be configured for as many as nine (9) different span gas values (Span). 5. Optional: Set instrument response factors if necessary (RF). 6. Optional: Take background reading (Backgnd). NOTE: Prior to performing calibration, the instrument must be on and warmed up for approximately 30 minutes. The pump must be ON, the PID lamp must be ON, and the FID must be ignited throughout the warm-up period. 25 MI 611-185 – June 1996 Display Menus Calibration Configuration Before you calibrate the TVA-1000B for the first time, you may want to customize certain calibration settings. Once you have configured these settings, you don’t need to set them again every time you calibrate unless you want to change one. In order to set your calibration options from the CALIBRATION menu, choose menu selection #1 (Cfg). This will produce the following CAL CONFIG MENUs which can be scrolled through by using the Up and Down arrows: Cal Config MENU 1= Number Span Pt. 2=Backgnd corrct Up/Dn=More Cal Config MENU 1= Accept Mode 2=Save Mode Cal Config MENU 1= RF calc mode Up/Dn=More Up/Dn=More Number Span Pt This selection allows you to determine the number of span points that will be used to calibrate your TVA-1000B. Choosing this selection will produce the following screen: PID: FID: 1 1 Span Pts. 1=Both 2=PID 3=FID From this screen, you may choose which detector you wish to set the number of span points for. Choosing one of these selections produces the following screens: FID only PID only FID/PID Number Span Pts: FID: 1 Number Span Pts: PID: 1 Number Span Pts: P&F: 1 Select: 1 to 9 Select: 1 to 9 Select: 1 to 9 From these screens, press the number of span points that you wish to use. Both detectors can have up to 9 span points each, and they do not necessarily need to have the same number of span points. IMPORTANT NOTE: If you choose to use more than one span point, data logged by the TVA-1000B cannot be downloaded to the original PC software supplied with old style TVA-1000A units. You must use the new PCIP software supplied with your new TVA-1000B to download this data. 26 Display Menus MI 611-185 – June 1996 Background Correct This selection allows you to choose whether or not to apply background correction to the detector readings displayed and logged in memory. If you choose to apply background correction, the last background reading stored in memory will be subtracted from the measured reading. This corrected reading will be the value displayed and the value logged. Choosing this selection from the CAL CONFIG MENU produces the following display: Backgrnd Correct: Off 1=Both 2=None 3=FID 3=PID The second line of the display shows what option is currently selected. You can change this option by choosing any one of the menu selections. You may choose to apply correction to FID, PID or both detectors. NOTE: A default background value of 0 is stored in memory until a background reading is taken. Cal Accept Mode This selection allows you to choose whether or not calibrations will be automatically accepted. Choosing this selection from the CAL CONFIG MENU produces the following display: Cal Accept Mode: Auto 1=Manual 2=Auto The second line of the display shows what option is currently selected. If “Manual” is chosen, the instrument will display the detector count during calibration and prompt the user to decide when to accept the calibration value:. If “Auto” is chosen, the instrument will automatically determine the value to be stored and when to do it. Cal Save Mode This selection allows you to choose whether or not the TVA-1000B will automatically save an accepted calibration. Choosing this selection from the CAL CONFIG MENU produces the following display: Cal Save Mode: Auto 1=Manual 2=Auto 27 MI 611-185 – June 1996 Display Menus The second line of the display shows what option is currently selected. If “Manual” is chosen, after a calibration value has been accepted the instrument will prompt the user to decide whether to save the calibration value or repeat the calibration (1 = Yes or 2 = Again?). If “Auto” is chosen, the instrument will automatically store the accepted calibration value without prompting the user. RF Calc Mode This selection allows you to choose how response factor correction will be applied to the reading. Choosing this selection from the CAL CONFIG MENU produces the following display: RF calc Mode: Factor 1=Factor 2=Curve The second line of the display shows what option is currently selected. If “Factor” is chosen, the TVA-1000B will use a single constant response factor which is multiplied by the reading. If “Curve” is chosen, the TVA-1000B will use a two constant equation. For more information, refer to the section of the manual on “Response Factors.” Detector Counts Detector counts are the raw, unscaled detector output values associated with a gas measurement performed by the FID or the PID. Before a detector reading is displayed or recorded, the detector signal is converted from analog to digital. The result is a raw number, or A/D counts. When a detector is calibrated, the detector counts for the zero gas and each of the span gases are saved in memory. These detector counts are then used as reference points for calculating the concentration values to be displayed or stored. When calibrating the TVA-1000B in the “Manual” accept mode, the counts from the last calibration (Zero or Span) are displayed before the calibration process is initiated. Once the calibration process is initiated, the live detector counts are then displayed. You can refer to these counts as an indication of when the reading has stabilized, or as a means of tracking the repeatability of your calibrations. You can also use these counts as an indication of the success of a calibration. The “zero” counts are the counts expected when a zero gas is applied to the detector. The span counts are the counts expected when a span gas of known concentration is applied to the detector. Finally, the detector sensitivity can be calculated by subtracting the zero counts from the span counts and dividing by the span gas concentration. Use the following general observations as a guideline: Detector Zero Counts FID 2000-4000 PID (10.6 eV lamp) 2000-20,000 PID (11.8 eV lamp) 2000-20,000 28 Detector Sensitivity 160-260 counts/ppm Methane 3500-6000 counts/ppm Isobutylene 300-900 counts/ppm Isobutylene Display Menus MI 611-185 – June 1996 Example: A TVA-1000B FID is calibrated with zero air and a 100 ppm Methane in air span gas. The counts observed for the zero are 2895 and the counts observed for the span are 27395. The span sensitivity is thus 245 counts/ppm [(27395-2750)/100 ppm]. Since both of these values (2895 zero counts and 245 detector sensitivity) are within the acceptable range, the calibration is a good calibration. Examples of a bad calibration include unusually high zero counts, or unusually low detector sensitivity. These problems can often be attributed to poor calibration gases, contaminated sampling accessories, a faulty detector capsule, or failure to follow the proper calibration procedure. For more information, consult the “Troubleshooting” guide in this manual or contact TEI for assistance. Defining the Span Gas Concentration(s) NOTES: 1. The span gas concentration is the known concentration of the gas standards used to calibrate your TVA. Methane in air is the recommended calibration standard for the FID, and Isobutylene in air is the recommended calibration standard for the PID. Other gases may be used if desired. 2. If your instrument is equipped with dual detectors, you may choose to calibrate the PID and FID separately or together. 3. If your instrument is configured for multiple span points, be sure to set the concentration for ALL span points. 1. From the CALIBRATION menu display, press 2=SpanConc. The upper display (or two displays if the unit is a dual detector version) will display the concentration value of your span gas (expressed as ppb, ppm, or %) as of the last calibration: FID only FID: 100 ppm Span Gas Concent Enter=New conc PID only PID: 100 ppm Span Gas Concent Enter=New conc FID/PID PID: 100 ppm FID: 100 ppm Span Conc 1=Both 2=PID 3=FID If the TVA-1000B is configured for multiple calibration points, the span gas concentration values for Point #1 will be displayed. The Up and Down arrow keys can be used to scroll through the span gas concentration values for other points: FID only FID: 100 ppm Span Pt 1 (Up/Dn) Enter=New conc PID only PID: 100 ppm Span Pt 1 (Up/Dn) Enter=New conc FID/PID PID: 100 ppm FID: 100 ppm Span Pt 1 (Up/Dn) 1=Both 2PID 3FID 29 MI 611-185 – June 1996 Display Menus 2. To change a span gas concentration value, choose the detector(s) of interest if using a dual detector analyzer, or press ENTER if using a single detector analyzer. The following display will appear: FID only PID only FID/PID Enter Span Conc: FID: 000000 ppm Up/Dn=Next unit Enter=Accept Enter Span Conc: PID: 000000 ppm Up/Dn=Next unit Enter=Accept Enter Span Conc: P&F: 000000 ppm Up/Dn=Next unit Enter=Accept Use the up and down arrow keys to select the measurement units (%, ppm, or ppb) and the decimal point position. There are 5 selections to choose from: Range 5 4 3 2 1 Display DD.DD DDDDDD DDDD.D DDD.DD DDDDDD Units % ppm ppm ppm ppb The range of the instrument is determined by your selection of measurement units and decimal point placement. In the run mode, the instrument will auto range upward only to select the optimum range for displaying measurement information. For example, if you entered a value in Range 3 and the measured value changes to a high value, the instrument will automatically switch to range 4. If it increases further, it will switch to Range 5. Auto-ranging will not switch ranges beyond the span gas range in the downward direction. After you have selected the measurement units and decimal point placement, use the keypad to enter the concentration value. Press ENTER to accept this value and store it in the TVA’s memory. 3. If your TVA-1000B is a dual detector analyzer, you may repeat the procedure for the second detector. If your TVA-1000B is configured for more than one span point, you may use the Up/Dn arrow keys to select the next span point and repeat the procedure. 4. When the last gas concentration value has been entered, you can return to the CALIBRATION menu, by pressing the EXIT key. Defining the Response Factor Although the FID and PID are calibrated with span gases of known concentration (usually Methane and Isobutylene, respectively), both detectors respond to many different compounds with differing levels of sensitivity. In order to adjust the analyzer reading from “ppm of Methane” or “ppm of Isobutylene” to ppm of the compound of interest, a correction factor must be applied to the reading. This correction factor is also known as a Response Factor. You can choose from up to nine (9) user-defined response factors, or use the default response factor of 1.00. Each response factor can be assigned a 9-character alphanumeric name. 30 Display Menus MI 611-185 – June 1996 The TVA-1000B uses one of two different response factor formats: a Multiplier or a Curve. Response Factor Multiplier A response factor multiplier is defined as follows: Actual Concentration Response Factor = ---------------------------------------------------------Measured Concentration Example: If 100 ppm of a compound produces an FID response of 50 ppm on an analyzer calibrated with Methane, then the FID response factor would be 2.00 (100/50). When using a response factor multiplier to correct a TVA-1000B reading, the analyzer multiplies the reading by the response factor and displays the corrected reading. As in the example give above, if a 50 ppm reading is obtained by the TVA-1000B, the analyzer would automatically multiply 50 times 2.00 to get the actual concentration of 100 ppm. Response Curve Response factors can change as concentration changes. The response factor for a compound determined at 500 ppm may not be the same as the response factor determined at 10,000 ppm. By using a response curve, you can characterize a compounds response over a broader range of concentrations. If the actual concentration is plotted as Y vs. X (measured concentration), the resulting curve can be represented by the rational equation AX Y = ---------------------------------------BX - 1 + ------------------------ 10000ppm When using the RF Calc Mode “curve”, the terms A and B are entered into the TVA-1000B. A represents the response factor multiplier at very low concentrations and B represents a change to the response for every percent concentration increase. The curve can only be defined by collecting response data at several different concentrations and using a xy math spreadsheet to calculate the “best-fit” polynomial expression. NOTE: Once the response curve has been fit, the calibration gas concentrations and number of span points should not be changed without readjusting the curve fit. To define and/or choose a response factor, choose 5=RF from the CALIBRATION menu. The following display will appear: RF0: Default Up/Dn=Next RF Enter=Accept The top line shows the currently active response factor. If no response factor is applied, the currently active response factor will be the factory DEFAULT (1.00 for FID methane and 1.00 for PID isobutylene). The name and value of the default response factor cannot be 31 MI 611-185 – June 1996 Display Menus changed. You can scroll through the other response factors by using the Up and Down arrow keys. The other response factor names will show as you scroll through them: RF1: Hexane Up/Dn=Next RF 1=Change Enter=Accept If you would like to activate a different response factor, press ENTER=Accept. The TVA-1000 will show an ACCEPTED message. If you would like to modify the response factor name or numbers, press 1=Change: PID only FID/PID FID only RF1: Hexane RF1: Hexane RF1: Hexane PID: 1.00 FID: 1.00 PID: 1.00 FID: 1.00 1=Name 2=Numbers 1=Name 2=Numbers 1=Name 2=Numbers If you would like to change the name assigned to the response factor, press 1=Name. If you would like to change the response factor value, press 2=Numbers. If you choose 1=Name, the following display will appear: Enter name: RF1: ------------Press char key Use the alphanumeric keypad to enter a compound name for the response factor. Press enter when you are finished. If you choose 2=Numbers, the following display will appear: FID only RF1: Hexane PID: 00.00 Enter=Accept PID only RF1: Hexane FID: 00.00 Enter=Accept FID/PID RF1: Hexane P&F: 00.00 Enter=Accept Use the keypad to enter a new response factor and press ENTER to store it in instrument memory. NOTES: 1. The TVA-1000B will not accept a response factor of 00.00. 2. If a response curve is used, the TVA-1000B will prompt you to enter two numbers. 32 Display Menus MI 611-185 – June 1996 Zero Reference Point Calibration 1. From the CALIBRATION menu display, press 3=Zero. NOTES: 1. The following sequence shows the procedure when the TVA-1000B is configured with both Cal Accept mode and Cal Save mode = Auto. If either mode is Manual, an extra confirmation is required at the appropriate step. 2. If your instrument is a dual detector type (PID and FID), you can zero the PID and FID separately, both together, or one in zero gas and one in clean ambient air. To do so, follow the same procedure. However, it is suggested that you zero both detectors together. If you press 3=Zero, the display will show: FID-only PID-only 0 FID: Zero Cal: Enter=Start PID/FID 0 PID: PID: FID: 0 0 Zero Cal: 1=Both 2=PID 3=FID Zero Cal: Enter=Start 2. To perform the actual ZERO procedure for an FID-only: or PID-only: or PID/FID: Press ENTER Press ENTER Press 1, 2, or 3 Apply Zero Gas FID Enter=Start Exit=Cancel Apply Zero Gas PID Enter=Start Exit=Cancel Apply Zero Gas At Sample inlet Enter=Start 3. Apply the zero gas to the probe at ambient pressure (using a clean and labeled gas sampling bag) and then press ENTER. FID FID Zero Gas Exit=Cancel 0 PID PID Zero Gas Exit=Cancel 0 PID FID: 0 0 Wait for Zero = =Cancel+ Exit = The instrument analyzes the zero sample. FID FID ACCEPTED 0 PID PID ACCEPTED 0 0 0 PID FID: - ACCEPTED - 33 MI 611-185 – June 1996 Display Menus The ACCEPTED message appears for a short time and is then replaced by the normal CALIBRATION menu. When the ACCEPTED message disappears and the CALIBRATION menu appears, the ZERO reference value is stored. This value is stored in non-volatile memory until the next calibration is performed. The date and time of this calibration are stored and can be accessed through the INFO menu. NOTE: For optimum accuracy, re-zero the FID every time the hydrogen supply valve is turned on. Span Reference Point(s) To set the span reference point, execute the procedure described below. Note that the procedure is the same as that for setting the zero reference except that a span gas is used instead of a zero gas. The procedure is: 1. From the CALIBRATION MENU display, press 4=Span. NOTES: 1. The following sequence shows the procedure when the TVA-1000B is configured with both Cal mode and Cal Save mode = Auto. If either mode is Manual, an extra confirmation is required at the appropriate step. 2. If your instrument is a dual detector type (PID and FID), you can set the span reference for the PID and FID separately, both together, or one in one type of calibration gas and one in another type of gas. To do so, follow the same procedure. 3. If multiple span points are used, repeat the following procedure for each and every span point. When you press 4=Span, the display will show: FID-only FID 7654321 Span P+1 (Up/Dn) Enter=New Calib PID-only PID 7654321 + Span P1 (Up/Dn) Enter=New Calib PID/FID PID 7654321 FID 7654321 Span Pt1 (Up/Dn) 1==Both 2Pid 3Fid If more than one reference span gas concentration has been configured, pressing the Up/Dn keys will allow you to scroll through all defined reference gas concentration points. 34 Display Menus MI 611-185 – June 1996 2. To perform the actual SPAN calibration (for example at 100 ppm): FID-only: Press ENTER Apply Span Gas FID: 100.00 ppm Enter=Start or PID-only: Press ENTER Apply Span Gas PID: 100.00 ppm Enter=Start or PID/FID: Press 1, 2, or 3 Apply Span Gas 100.00 ppm Enter=Start 3. Apply the appropriate span gas to the probe at ambient pressure (using a clean and labeled gas sampling bag) and then press ENTER. FID 7654321 FID: 100.00 ppm Wait for Span Exit=Cancel PID 7654321 PID: 100.00 ppm Wait for Span Exit=Cancel PID 7654321 FID 7654321 Wait for Span Exit=Cancel The instrument analyzes the span sample. FID 7654321‘ -ACCEPTED- PID 7654321 -ACCEPTED- PID 7654321 FID 7654321 -ACCEPTED- When only one reference span gas concentration is used, the ACCEPTED message appears for a short time and is then replaced by the normal CALIBRATION menu. When the ACCEPTED message disappears and the CALIBRATION menu appears, the SPAN reference value is stored. This value is stored in non-volatile memory until the next calibration is performed. The date and time of this calibration are stored and can be accessed through the INFO menu. 4. If more than one reference span gas concentration has been defined, the span calibration display returns. Move to the next concentration point (Up/Dn keys) and repeat steps 2-3 above until each reference gas concentration point has been calibrated. Alarm Levels The TVA-1000B is supplied with three user-configurable alarms — HI Ceiling, Low Ceiling, and STEL (short term exposure limit). When any of these alarms is exceeded, an alarm message appears on the sidepack display and probe display (enhanced version only) and an alarm tone is generated. Press EXIT to acknowledge the alarm message and sounder. Once acknowledged, the display returns to the live measurement with an upper case letter representing the alarm or alarm combination appearing to the right of the display. The three types of user configurable alarms are: 35 MI 611-185 – June 1996 Display Menus Alarm Type Low Ceiling: High Ceiling: STEL: Description This alarm is a warning that a lowest level threshold has been exceeded. Once acknowledged, the letter L appears to the right of the live measurement for the appropriate detector. This alarm is a warning that a second, higher level, threshold has been exceeded. Once this alarm is acknowledged, the letter H appears to the right of the live measurement for the appropriate detector. The Short Term Exposure Limit alarm indicates that measurements averaged over a 15-minute interval have exceeded the set alarm limit. Once this alarm is acknowledged, the letter S appears to the right of the live measurement for the appropriate detector. The three alarm messages appear on the instrument display as follows: Low Ceiling High Ceiling STEL Level ALARM!== Low ceiling alarm exceeded! Exit=Clr ALARM!== High ceiling alarm exceeded! Exit=Clr =ALARM!== STEL alarm level exceeded! Exit=Clr NOTE: To display and change the alarm menus, the instrument must be ON but does not have to be warmed up. Accessing the Alarm Menu 1. From the MAIN menu display, press 2=Setup. 2. From the SETUP menu display, press 2=Alarms and follow the procedures for the appropriate alarm settings: STEL Level Alarm 1. From the ALARM LEVELS display, press 1=STEL. The previous alarm settings for STEL alarm are then displayed, as follows. FID-only FID: 80.00 ppm STEL Alarm Enter=New Value 36 PID-only PID: 80.00 ppm STEL Alarm Enter=New Value PID/FID PID: 80.00 ppm FID: 80.00 ppm STEL: 1=Both 2=PID 3=FID Display Menus MI 611-185 – June 1996 2. To change the alarm level to a new value, press ENTER on a single detector instrument or 1, 2, or 3 on a dual detector instrument and see: FID-only Enter STEL: FID: 000.00 ppm Up/Dn=Next Unit Enter=Accept PID-only Enter STEL: PID:000.00 ppm Up/Dn=Next Unit Enter=Accept PID/FID Enter STEL: P&F:000.00 ppm Up/Dn=Next Unit Enter=Accept Use the up and down arrow keys to select %, PPM, PPB, and decimal point position, then type the numeric value for the alarm level desired. 3. Press ENTER to store new values into instrument memory. 4. Press EXIT to return to the ALARM LEVELS without making a change. Low Ceiling Alarm 1. From the ALARM LEVELS display, press 2=Low Ceiling. The previous alarm settings for the Low Ceiling alarm are then displayed, as follows. FID-only FID: 80.00 ppm Low Ceiling Alarm Enter=New Value PID-only PID: 80.00 ppm Low Ceiling Alarm Enter=New Value PID/FID PID: 80.00 ppm FID: 80.00 ppm Low Ceiling: 1=Both 2=PID 3=FID 2. To change the alarm level to a new value on a single detector instrument, press ENTER; on a dual detector instrument, press 1, 2, or 3, and see: Enter low ceil: FID: 000.00 ppm Up/Dn=Next Unit Enter=Accept Enter low ceil: PID:000.00 ppm Up/Dn=Next Unit Enter=Accept Enter low ceil: P&F:000.00 ppm Up/Dn=Next Unit Enter=Accept Use the up and down arrow keys to select %, PPM, PPB, and decimal point position, and then type the numeric value for the alarm level desired. 3. Press ENTER to store the new values into instrument memory. 4. Press EXIT to return to the ALARM LEVELS. 37 MI 611-185 – June 1996 Display Menus High Ceiling Alarm 1. From the ALARM LEVELS display, press 3=High Ceiling. The previous alarm settings for the High Ceiling alarm are displayed. FID-only FID: 80.00 ppm High Ceiling Alarm Enter=New Value PID-only PID: 80.00 ppm High Ceiling Alarm Enter=New Value PID/FID PID: 80.00 ppm FID: 80.00 ppm High Ceiling: 1=Both 2=PID 3=FID 2. To change the alarm level to a new value, press ENTER on a single detector instrument or 1, 2, or 3 on a dual detector instrument and see: Enter high ceil: FID: 000.00 ppm Up/Dn=Next Unit Enter=Accept Enter high ceil: PID:000.00 ppm Up/Dn=Next Unit Enter=Accept Enter high ceil: P&F:000.00 ppm Up/Dn=Next Unit Enter=Accept Use the up and down arrow keys to select %, PPM, PPB, and decimal point position, and then type the numeric value for the alarm level desired. 3. Press ENTER to store the new values into instrument memory. 4. Press EXIT to return to the ALARM LEVELS display. Log Methods Selecting the LOG mode not only identifies the way in which data is stored in instrument memory but also governs the way the RUN mode works. Four possible choices in the LOG mode are available. Each is explained below. Option Description 1. NONE Selecting None means that no logging action takes place at all. When the instrument is in the RUN mode, you can only display readings. 2. AUTO When you select and configure the AUTO method, the RUN mode functions automatically once an action is initiated. You choose an automatic logging rate between 1 second and 999 minutes, type a tag* identifier, and start the instrument. You initiate automatic sampling by either pressing the LOG key on the probe or the ENTER key on the instrument. From that point on, the instrument automatically logs the reading of the sample at the end of each countdown and continues to do so until the battery goes low or you press the EXIT key. 38 Display Menus Option 3. VOC 4. F.E. MI 611-185 – June 1996 Description The VOC method of sampling is a manual means of triggering a sample/log. Once configured for VOC, the RUN mode prompts you to type a tag* identifier. After you enter the tag, the instrument stands ready until you press either the LOG key on the basic probe or the ENTER key on the instrument. Once LOG is initiated, the instrument counts down. Samples are taken over that count down and the highest reading achieved, or average (or last) reading is logged in memory and displayed on both displays. The stored values are cleared by pressing either the LOG key on the basic probe or the ENTER key on the instrument. Each VOC log must be done manually and individually. The F.E. method of sampling is a manual means of triggering a sample/log using a pre-configured monitor route file which has been downloaded and stored in instrument memory. The F.E. method requires use of the optional enhanced FE probe. You choose a sample time of between 2 and 20 seconds and you choose to log either the highest reading or average (or last) reading achieved during the sample time. Once configured for F.E. and the RUN mode entered, the FE probe menu screen guides you through the monitor route, displaying each pre-configured tag identifier in sequential order. A SEARCH function is available at the probe menu to allow you to find tags that are out of order. The probe display prompts you to confirm the tag* identifier, after which the instrument stands ready until you either select LOG from the probe or press the ENTER key on the instrument. Once initiated, the instrument begins a count down, sampling over the configured sample time. The reading sampled during the countdown is displayed on both displays and your are given the option to save the reading in memory or to select LOG again. The stored values are cleared by selecting LOG on the probe display or by pressing ENTER on the instrument. Each F.E. log must be done individually and manually. *Tags may be entered manually or via a reader. The RUN mode displays (as governed by the LOG selection) are: NONE AUTO, VOC, or F.E. PID: 80.00 ppm FID: 80.00 ppm Exit=Stop or PID: 80.00 ppm FID: 80.00 ppm Logging: 10 sec Exit=Stop NOTE: To display and change the log menu, the instrument must be ON but does not have to be warmed up. 39 MI 611-185 – June 1996 Display Menus Accessing the LOG Menu 1. From the MAIN MENU display, press 2=Setup. 2. From the SETUP MENU display, press 3=Log. The following display will appear: Log Mode None 1=None 2=Auto 3=VOC/FE 4=Custom The previous log selection is displayed on the second line. Follow the procedure below to set the log mode. Log None 1. From the LOG MODE Menu, press 1=None. LOG MODE Auto, rate=5 sec 1=None 2=Auto 3=VOC/FE 4=Custom Press 1=None to display this message briefly. The screen then returns to the SETUP menu. = None -ACCEPTED- Log Auto From the LOG MODE Menu, press 2=Auto. The previous log selection is then displayed on the second line of the screen. LOG MODE None 2=Auto 1=None 3=VOC/FE 4=Custom Press 2=Auto to display this message. Enter log rate: Auto, rate=000sec Up/Dn=Sec↔Min Enter=Accept 2. Use the up and down arrow to select minutes (min) or seconds (sec). Then, type the appropriate time interval desired for the automatic sampling. 3. Press ENTER and, after a brief message of acceptance, the automatic sampling is ready to be used in the RUN Mode. NOTE: To allow for STEL calculations in the personal computer utility, the log rate value must be less than 90 seconds. If a log rate greater than 90 seconds is selected, a warning message will appear. Press EXIT to bypass this message and proceed. 40 Display Menus MI 611-185 – June 1996 In the LOG AUTO mode, data is logged in the format described below: 1. Every time RUN mode is entered a new header is created. 2. Data is logged periodically, at the user-entered log rate, in the following format: Date 7/28/93 7/28/93 7/28/93 7/28/93 7/28/93 Time 11:20:57:00 11:21:29:00 11:21:54:00 11:22:19:00 11:22:36:00 PID (PPM)Alarms 187.1 L 436.6 H 708.4 LH 300.7 L 223.8 FID (PPM) Alarms 157.1 L 519.6 L 847.0 LH 381.9 L 265.1 Approximately 9500 data samples may be taken with a single header. Log VOC 1. From the LOG MODE Menu, press 3=VOC/FE, then 1=VOC. LOG MODE Auto,rate=12 sec 1=None 2=Auto 3=VOC 4=FE Press 3, then 1 to display this message. Enter Sampling: Voc, Time=00s, Max Up/Dn=Next type Enter=ACCEPT 2. Press the Up/Dn arrow keys to choose the type of sampling to be used (Max, Avg, Smp). a. Max=the maximum reading obtained during the log interval. b. Avg=the average reading obtained during the log interval. c. Smp=the last reading obtained during the log interval. 3. Type the appropriate time interval desired for VOC sampling. 4. Press ENTER, and, after a brief message of acceptance, the VOC method of logging is now ready to be used in the RUN Mode. NOTE: The allowable Sample Time range is 2-30 seconds. If a Sample Time of less than 2 seconds or greater than 30 seconds is selected, a warning message will appear and you will be required to re-enter the Sample Time. 41 MI 611-185 – June 1996 Display Menus In the LOG VOC mode, data is logged in the format described below: 1. Every time RUN mode is entered a new header is created. 2. Data is logged in the following format whenever you press the LOG button: Date 7/28/93 7/28/93 7/28/93 7/28/93 7/28/93 Time 11:20:57:00 11:21:29:00 11:21:54:00 11:22:19:00 11:22:36:00 PID (PPM) Alarms 187.1 L 436.6 H 708.4 LH 300.7 L 223.8 FID (PPM) Alarms 157.1 L 519.6 L 847.0 LH 381.9 L 265.1 Tag TAG1 TAG2 TAG3 TAG4 TAG5 Approximately 4500 data samples may be taken. Log F.E. 1. From the LOG MODE menu, press 3=VOC/FE, then 2=FE The previous log selection is then displayed on the second line of the screen. Press 3=VOC/FE, then 2=FE to display LOG MODE Logging=VOC, Time=05s, this message. Max 1=None 2=Auto 3=VOC/FE 4=Custom Enter Sampling: FE,Time=00s, Max Up/Dn=Next Type Enter=ACCEPT 2. Press the Up/Dn arrow keys to choose the type of sampling to be used (Max, Avg, Smp). a. Max = the maximum reading obtained during the log interval. b. Avg = the average reading obtained during the log interval. c. Smp = the last reading obtained during the log interval. 3. Type the appropriate time interval desired for F.E. sampling. 4. Press Enter, and, after a brief message of acceptance, the F.E. method of logging is now ready to be used in the RUN mode. NOTE: The allowable Sample Time range is 2-30 seconds. If a Sample Time of less than 2 seconds or greater than 30 seconds is selected, a warning message will appear and you will be require to re-enter the Sample Time. Log Custom The TVA-1000B has several pre-designed logging methods. However, if you find that you would prefer to log data in a different fashion, you can use Custom logging to create your own log type. The TVA-1000B will prompt you through a series of questions which will assist you in setting the various logging options. The end result is a logging method which collects data the way you want it to. 42 Display Menus MI 611-185 – June 1996 The following variable settings can be configured when designing a Custom log method: 1. Log data type This setting allows you to choose the format in which data will be saved. The choices are as follows: a. None. b. Auto – Data stored in a fashion similar to Auto logging for download to the TEI datalogging software only (tag, calibration information, Detector Counts, time/ date, alarms). c. VOC – Data stored in a fashion similar to VOC logging for download to the TEI datalogging software only (Tag, Calibration Information, Detector Counts, time/date, alarms). d. FE – Data stored in a fashion similar to FE logging for download to FEMS or via the Text protocol. 2. Sample time This setting allows you to adjust the sampling interval. 3. Log time units This setting allows you to choose the units for the sample interval (seconds or minutes). 4. Log sample type This setting allows you to choose the way in which sample readings are collected over the sample rate or interval. The choices are as follows: a. Last sample — the last reading obtained within the sample interval is stored b. Max — the maximum reading obtained within the sample interval is stored c. Avg — the average reading obtained over the sample interval is stored 5. Log unit lock This setting allows you to decide whether to enable auto-ranging or lock the TVA-1000 units to one of three choices: ppb, ppm, or %. 6. Log auto repeat This setting allows you to determine whether the TVA-1000B should automatically cycle through logging events (auto repeat ON) or pause for a user command before logging (auto repeat OFF). 7. Log save accept This setting determines whether the TVA-1000B prompts the user before saving a logged reading (Manual) or automatically saves the reading without a user prompt (Auto). 8. Tag active This setting determines whether or not you want to assign tags to logged readings. If you wish to assign tags, choose ON. If you wish to skip tagging, choose OFF. 43 MI 611-185 – June 1996 Display Menus 9. Route active This setting determines whether the logging should follow a pre-loaded route list of tags. If you wish to upload a list of tags to the TVA-1000B and follow that list while logging, choose ON. If you do not wish to use routing, choose OFF. 10. Barcode reader This setting determines whether the barcode reader is used merely to enter tags (Enter tag) or if it is required to verify that the user has read a tag in the monitoring route (Verify tag). Hardware Configuration (Barcode Reader/Probe Display) NOTE: To select a barcode reader or probe display, the instrument must be ON but does not have to be warmed up. The TVA-1000B must be configured to operate with the appropriate barcode reader and probe display. To select which accessories to use: 1. From the MAIN menu display, press 2 = Setup. 2. From the SETUP menu display, press 5 = Hardware. The Hardware menu will appear: Hardware Menu 1=Probe Display 2=Barcode Reader To select a probe display: 1. From the HARDWARE menu, choose 1 = Probe display. The PROBE DISPLAY menu will appear: Probe display Basic 1=Basic 2=Enhanced 2. The second line of the display shows the currently configured display type. To choose the basic probe display, press 1. To choose the Enhanced FE probe display, press 2. To select a barcode reader: 1. From the HARDWARE menu, choose 2 = Barcode reader. The BARCODE menu will appear: Barcode Menu None 1=Select Reader ENTER=Initialize 44 Display Menus MI 611-185 – June 1996 2. The second line of the display shows the currently configured barcode scanner type. To select a reader, press 1. The BARCODE READERS menu will appear: Barcode Readers 1=None 2=HP Smart Wand 3=PSC Laser 3. To choose no reader, press 1. To choose the HP Smart Wand, press 2. To choose the PSC laser scanner, press 3. 4. To initialize a reader, ensure that the reader is plugged into the 9-pin reader port and securely fastened in place. From the BARCODE menu screen, press ENTER=Initialize. The message “Barcode reader initialization in progress” will appear. A successful initialization will result in an “Initialization Complete” message. If the reader is not properly connected or if an incorrect model is connected, a “WARNING: Barcode reader not found” message will appear. WARNING: Not all readers are approved for use in areas classified as hazardous due to the presence of flammable gases or vapors. Contact TEI for more information. User Identification Number NOTE: To set the User ID number, the instrument must be ON but does not have to be warmed up. 1. From the MAIN menu display, press 2=Setup. 2. From the SETUP menu display, press 6=Othr. 3. From the OTHER SETTINGS menu, press 1=User ID. 4. From the User ID prompt, press ENTER. 5. Use the keypad to type your user ID. 6. Press ENTER to store the user ID into memory. Date NOTE: To set the correct date, the instrument must be ON but does not have to be warmed up. Date entries earlier than Jan. 1, 1980 or later than 2037 are invalid. 1. From the MAIN menu display, press 2=Setup. 2. From the SETUP menu display, press 6=Othr. 3. From the OTHER SETTINGS menu, press 2=Date. 4. The next screen reads the current date. If OK, press EXIT or ENTER to change. EXIT returns to the OTHER SETTINGS menu. ENTER prompts you to type 45 MI 611-185 – June 1996 Display Menus the correct date. Do so by typing month/day/year, and then press ENTER to store the date in memory. The display then returns to OTHER SETTINGS. Time of Day NOTE: To set the correct time, the instrument must be ON but does not have to be warmed up. The date must be within the valid range of 1980 to 2037. 1. From the MAIN menu display, press 2=Setup. 2. From the SETUP menu display, press 6=Othr. 3. From the OTHER SETTINGS menu, press 3=Time. 4. The next screen reads the current time. If it is OK, press EXIT or ENTER to change. EXIT returns to the OTHER SETTING Menu, ENTER prompts you to type the correct time. Do so by typing hour/minute/second. Then press ENTER to store the time in memory. The display then returns to OTHER SETTINGS. User Options Key Click If the key click is on, a chirp is heard every time a key is pressed. NOTE: To select key click on/off, the instrument must be ON but does not have to be warmed up. 1. From the MAIN MENU display, press 2=Setup. 2. From the SETUP MENU display, press 6=Othr. 3. From the OTHER SETTINGS Menu, press 4=User Options. 4. From the USER OPTION Menu, press 1=Key Click. 5. From the Key click Menu, press 1=On or 2=Off. The screen displays the previous selection. When a new selection is made, the display returns to USER OPTIONS. Display Delay This function determines the length of time that temporary messages remain on the screen. NOTE: To select the display delay, the instrument must be ON but does not have to be warmed up. 1. From the MAIN menu display, press 2=Setup. 2. From the SETUP menu display, press 6=Othr. 3. From the OTHER SETTINGS menu, press 4=User Options. 46 Display Menus MI 611-185 – June 1996 4. From the USER OPTION menu, press 2=Display Delay. 5. From the Display Delay menu, press 1=Short, 2=Medium or 3=Long. The screen displays the previous selection. When a new selection is made, the display returns to USER OPTIONS. NOTE: “Short” is approximately 0.5 sec, “Medium” is approximately 1.5 seconds, and “Long” is approximately 3.5 seconds. Information Menu The information menu is a view-only list of 14 items/parameters existing in the instrument. No changes may be made in this menu. Enter the INFO Menu from the MAIN menu by pressing 3=Info. Use the up/down keys to page through the list. The parameters/items you may view are: ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Model: TVA-1000B S/N DDDDDDDDDDDD Date Time Memory: how much is free to use Reader: Serial reader is found or not found Ver: Current Software Version No. PID span calibration: Date and time of last calibration FID span calibration: Date and time of last calibration PID zero calibration: Date and time of last calibration FID zero calibration: Date and time of last calibration Det: PID, FID, or both Pump: On or Off Bat: Battery voltage listed, OK or low NOTE: To view calibration information, you must return to the calibration menu in SETUP. Press EXIT to return to MAIN menu. PC Link/Memory WARNING: The RS-232 port is not approved for use in areas classified as hazardous due to the presence of flammable gases or vapors. This menu allows you to link the TVA-1000B to a personal computer (PC) through the RS-232 communications port or to clear existing route or log memory within the instrument. 47 MI 611-185 – June 1996 Display Menus To enter the PCLINK/MEMORY menu from the MAIN menu, press 4=PCLink/Memory. The following display will appear: PCLINK/MEMORY 1 = PC Link 2 = Clear Route & Logging Memory Choosing 2 = Clear Route & Logging Memory will erase any downloaded routes or any logged data stored in TVA-1000B memory. A warning that “You are about to clear all memory” will appear and must be acknowledged before the TVA-1000B will clear its memory. Be absolutely sure that you wish to clear memory before choosing this action. Once memory is cleared, it cannot be retrieved. Choosing 1 = PCLink will allow you to either change the TVA’s communications protocol, or begin to send or receive data. One of the following displays will appear: PCLINK Type=FEMS 1=Change Type 2=Send 3=Receive PCLINK Type=TVAPC 1=Change Type 2=Establish Link PCLINK Type=Text - Manual 1=Change Type 2=Send 3=Receive PCLINK Type=Text - Auto 1=Change Type 2=Establish Link The second line of the display shows the type of communications protocol the TVA-1000B is currently set to use. Choosing 1 = Change type will allow you to select a new communications protocol: PCLINK TYPE Type=TVAPC 1=TVAPC 2=FEMS 3=Text Choosing 1 = Foxboro will configure your TVA-1000B to communicate with the TEI TVA-1000 Datalogging software. Choosing 2=FEMS will allow your TVA-1000B to communicate with Envirometrics’ F.E.M.S. (Fugitive Emissions Monitoring Software). Choosing 3=Text will allow your TVA-1000B to output data in a straight ASCII text format to a serial printer, terminal emulation software, or the PCIP software supplied with your TVA-1000B. This ASCII format can be read and understood by many commercially available spreadsheets and data management software packages. If you choose Text mode, you will also need to select whether the communications will occur automatically (if your software is set up to automatically command the TVA-1000B; e.g., the PCIP) or manually (if you need to send commands from the keypad). 48 Display Menus MI 611-185 – June 1996 TEI TVA-1000B Software Link NOTE: If you are using a mulitpoint calibration curve, you cannot download your data to the PC via the TEI TVA-1000 software. Use the text transfer mode to download to an ASCII file. 1. Connect the cable between the PC serial port and the RS-232 port of the TVA-1000B (marked HOST). 2. Enter the PC LINK menu and change the link type (1 = Change type) to Foxboro. If the link type is already set to Foxboro, proceed to the next step. 3. From the PC LINK menu, choose 2 = Establish link. The following display will appear: PC LINK STATUS Waiting for PC Request ... Exit=Cancel For more information about the TVA-1000A Datalogging software, refer to MI 611-187, PC Software. F.E.M.S. Software Link Receive Before the TVA-1000B can be used in FE logging mode, a previously configured route file must be created in F.E.M.S. and downloaded to the instrument’s memory. Use the following instructions to download a route to the TVA-1000B from F.E.M.S.: 1. Connect the cable between the PC serial port and the RS-232 port of the TVA-1000B (marked HOST). 2. Enter the PC LINK menu and change the link type (1 = Change type) to F.E.M.S. If the link type is already set to F.E.M.S., proceed to the next step. 3. Before attempting to download, be sure that F.E.M.S. is configured to operate with the TVA-1000B: File/Preferences Window: Datalogger set to “Foxboro TVA-1000B” Monitor Run/Communications Window: 9600 baud, 8 data bits, 1 stop bit, no parity If these parameters are already properly set, proceed to the next step. 4. Follow the F.E.M.S. instruction manual to create a monitoring route for downloading to the TVA-1000B. 5. When F.E.M.S. instructs you to set the datalogger so that it is ready to accept data, choose 3=Receive from the PC LINK menu. A warning will appear informing you 49 MI 611-185 – June 1996 Display Menus that the new route will erase any existing route. Once you have acknowledged this warning by pressing ENTER, the following display will appear: PC LINK STATUS Waiting for PC Connection ... Exit=Cancel NOTE: Do not place the TVA-1000B into this wait mode until F.E.M.S. instructs you to. Doing so will cause the TVA-1000B and F.E.M.S. handshaking to fail. 6. Now that the TVA-1000B is waiting to receive data, click on OK at the F.E.M.S. window, instructing F.E.M.S. to begin the download. 7. Once F.E.M.S. has finished sending the route to the TVA-1000B, the TVA-1000B display will read “PC data transfer successfully completed” and return to the PC LINK menu. Send Once the TVA-1000B has been used to collect fugitive emissions data in the FE monitoring mode using a F.E.M.S. created route, the data can then be uploaded to the PC. Use the following instructions to upload data from the TVA-1000B to F.E.M.S.: 1. Connect the cable between the PC serial port and the RS-232 port of the TVA-1000B (marked HOST). 2. Enter the PC LINK menu and change the link type (1=Change type) to F.E.M.S. If the link type is already set to F.E.M.S., proceed to the next step. 3. Before attempting to upload, be sure that F.E.M.S. is configured to operate with the TVA-1000B: File/Preferences Window: Datalogger set to “Foxboro TVA-1000B” Monitor Run/Communications Window: 9600 baud, 8 data bits, 1 stop bit, no parity If these parameters are already properly set, proceed to the next step. 4. When F.E.M.S. instructs you to set the datalogger so that it is ready to send data, choose 2 = Send from the PC LINK menu. The following display will appear: PCLINK STATUS Waiting for PC Connection ... Exit=Cancel NOTE: Do not place the TVA-1000B into this wait mode until F.E.M.S. instructs you to. Doing so will cause the TVA-1000B and F.E.M.S. handshaking to fail. 50 Display Menus MI 611-185 – June 1996 5. Now that the TVA-1000B is waiting to send data, click on OK at the F.E.M.S. window, instructing F.E.M.S. to begin the upload. 6. Once the analyzer has finished sending the data to F.E.M.S., the TVA-1000B display will read “PC data transfer successfully completed” and return to the PC LINK menu. Text Transfer The TVA-1000B is also capable of data transfer to an IBM PC running software to emulate a terminal. The data is formatted as readable ASCII text. The following information can be uploaded from the TVA-1000B to the PC: a. Route List b. TVA-1000B Configuration c. TVA-1000B Calibration Parameters d. Logged Data The following information can be downloaded from a PC to the TVA: a. Route List b. TVA-1000B Configuration c. TVA-1000B Calibration Parameters Two control modes are supported: a. Manual – the user requests a specific text upload or download at the TVA-1000. b. Auto – the TVA-1000B performs a specific text upload or download as requested by a control character received from the IBM PC. The TVA-1000B stays in this mode until canceled by the user at the TVA-1000B or by a control code from the IBM PC. Communications A commercially available PC communications software package is required to establish a link with the TVA-1000B. Examples of such packages include PROCOMM PLUS and Windows Terminal. The following settings should be used: Baud Rate: Data Bits: Stop Bit: Parity: Flow Control: 9600 7 1 Odd XON/XOFF The data can be uploaded from the TVA-1000B to a file, a terminal screen or a serial printer. Data can also be downloaded to the TVA-1000B. Downloaded files must follow the format prescribed in this manual precisely to ensure proper data transmission. 51 MI 611-185 – June 1996 Display Menus Text Data Formats Messages to be uploaded and downloaded must be written in straight ASCII text and must contain blank spaces between text, not tabs. For more information on Text Data Formats, see Appendix A. Downloading Data from the PC to the TVA-1000B (Manual) 1. Connect the cable between the PC serial port and the RS-232 port of the TVA-1000B (marked HOST). 2. Enter the PC LINK menu and change the link type (1 = Change type) to TextManual. If the link type is already set to Text, proceed to the next step. 3. From the PC LINK menu, choose 3 = Receive. 4. The TVA-1000B will warn you that new data will automatically erase old data. Once you have acknowledged this warning, the following screen will appear: PC LINK STATUS Waiting for PC to send data ... Exit=Cancel 5. Following the instructions from your PC software package, command the PC to send the appropriate file. 6. When the text transfer is complete, the TVA-1000B display will read “PC data transfer successfully completed.” NOTE: For more information about sending data with your communications software, consult your software users manual. Uploading Data from the TVA-1000B to the PC (Manual) 1. Connect the cable between the PC serial port and the RS-232 port of the TVA-1000B (marked HOST). 2. Enter the PC LINK menu and change the link type (1 = Change type) to TextManual. If the link type is already set to Text, proceed to the next step. 3. Prepare your PC communications software so that it is ready to receive data. For more information, consult your PC communications software users manual. 4. From the PC LINK menu, choose 2 = Send. 5. The TVA-1000B will ask you what data you wish to send (Route, Configuration, Log data, or Calibration). Select the data that you wish to transmit. 52 Display Menus MI 611-185 – June 1996 6. The following screen will appear: PC LINK STATUS Sending data to PC... Exit=Cancel 7. When the text transfer is complete, the TVA-1000B display will read “PC data transfer successfully completed.” NOTE: For more information about receiving data with your communications software, consult your software users manual. Auto Upload/Download NOTE: Text-Auto is used to communicate with the PCIP software shipped with your unit. For more information, refer to MI 611-186. 1. Connect the cable between the PC serial port and the RS-232 port of the TVA-1000B (marked HOST). 2. Enter the PC LINK menu and change the link type (1 = Change type) to TextAuto. If the link type is already set to Text-Auto, proceed to the next step. 3. Prepare your PC communications software so that it is ready to send or receive data. For more information, consult your PC communications software users manual. 4. From the PC LINK menu, choose 2 = Establish Link. 5. The following screen will appear: PC LINK STATUS Waiting for PC request... Exit=Cancel 6. Follow the instructions included with your software package to send control messages and data to the TVA. Commands to upload data will trigger the TVA-1000B to send the appropriate information to the PC. Commands to download data will trigger the TVA-1000B to wait to receive information from the PC. The following table illustrates which control keys command which activities: Activity Upload to PC from TVA Upload to PC from TVA Upload to PC from TVA Upload to PC from TVA Information Route List TVA-1000B Configuration TVA-1000B Calibration Logged Data Auto Control Key CTRL-E CTRL-G CTRL-L CTRL-D 53 MI 611-185 – June 1996 Display Menus Activity Information Auto Control Key Download from PC to TVA Route List CTRL-R Download from PC to TVA TVA-1000B Configuration CTRL-F Download from PC to TVA TVA-1000B Calibration CTRL-B Download from PC to TVA Any of the above CTRL-Y Abort the current transfer N/A CTRL-A Terminate link N/A CTRL-T 7. After any transfer, the TVA-1000B may then be commanded to perform another transfer. When you are finished transferring data, a CTRL-T command should be sent (or press the EXIT key on the sidepack) to terminate the connection. The TVA-1000B will then display a “Connection terminated” message and return to the PCLink menu. NOTE: For more information about sending or receiving data with your communications software, consult your software users manual. Run Mode How the instrument functions in the RUN mode is governed by the selection made in the SETUP/LOG menu. The LOG menu selects how data is stored in the instrument memory. There are four possible choices in the LOG mode as defined in “Log Methods” on page 38. The TVA-1000B performs accurately only after it has been properly set up (configured). The three RUN mode displays (as governed by the LOG Selection) are: NONE AUTO, VOC, or F.E. PID: 80.00 ppm FID: 80.00 ppm Exit=Stop PID: 80.00 ppm FID: 80.00 ppm Sampling: 10 sec Exit=Cancel If your instrument is equipped with an FID, you should turn the red hydrogen supply valve to ON and wait 2-3 minutes before entering the RUN mode. Upon entering the RUN mode, the pump will automatically turn ON and the FID will ignite. NOTE: For best performance, prior to entering the RUN mode, the instrument must be ON, warmed up for approximately 15 minutes, and display the main menu. The pump must also be ON throughout the warmup period. If the instrument is FID equipped, and the FID is to be used, the flame must be ignited throughout the warmup period. If the instrument is PID equipped and the PID is to be used, the lamp must be ON throughout the warmup period. 54 Display Menus MI 611-185 – June 1996 Accessing the Run Menu From the MAIN MENU display, press 1=Run. Run: Log None Whenever the TVA-1000B is in the RUN mode with Log None as the logging selection, the instrument operates as a survey tool only. The readings on the probe display and instrument display show the live reading for the samples at that time. No logging action is taking place. Any alarms that are set will function normally. PID: 225.ppm FID: 225.ppm Exit=Stop Run: Log Auto Whenever the TVA-1000B is in the RUN Mode with Log Auto as the logging selection, the instrument operates as an automatic survey tool PID: 225.ppm FID: 225.ppm that logs its readings into memory at an interval selected in the Setup _ Menu. After the 1=Run key is pressed, the first screen viewed is the one Press char key shown at the right. The tag information should be typed in before starting or a tag read with the barcode scanner. The tag may be left blank if desired. Type the tag information in the space provided or scan a tag with the reader. Once the tag information is entered, press the ENTER Key. The screen then changes to the next display. The instrument is now ready to start logging. The screen displays live readings and the tag name. However, no logging takes place until you press either the LOG key on the basic probe or the ENTER key on the instrument. Press ENTER or the LOG key on the basic probe to start the automatic logging. The instrument counts down from the time selected in the SETUP/Log Menu and stores the reading at the end of the count down. For instance, if 12 seconds was selected as the logging time, the instrument will count down from 12 and display 11,10,9,8,7,6,5,4,3,2,1,store. The instrument logs into memory either the highest, average, or last reading during the countdown. PID: 225.ppm FID: 225.ppm Tag: BLDG 19 Press char key PID: 225.ppm FID: 225.ppm BLDG 19 Enter=Start log PID: 225.ppm FID: 225.ppm Sampling: 11sec Exit=Stop This action continues until the instrument shuts down due to low battery or the EXIT key is pressed. 55 MI 611-185 – June 1996 Display Menus Run: Log VOC Whenever the TVA-1000B is in the RUN mode with Log VOC as the PID: 225.ppm logging selection, the instrument operates as a manual survey tool that FID: 225.ppm logs its readings into memory whenever you initiate logging. When the _ _ _ Press char key 1=Run key is pressed, the first screen viewed is the one shown on the right. The tag information should be typed or a tag read with the barcode scanner. The tag may be left blank if desired. Enter the tag information in the space provided (up to 10 characters) PID: 225.ppm or scan a tag with the reader. Once the tag information is entered, press FID: 225.ppm Tag: BLDG 19__ the ENTER key. The screen then changes to the next display. Press char key The instrument is now ready to start logging. The screen displays live readings and the tag name but no logging takes place until you press either the LOG key on the basic probe or the ENTER key on the instrument. Press ENTER or LOG to start the VOC logging sequence. After the instrument counts down for the time selected in the SETUP/Log menu, the word Save appears. When confirmed, the instrument logs into memory either the highest average or last reading achieved during the countdown sample. After the information is stored into memory, the display returns to live measurements and prompts for a new tag. Each VOC log must be done manually and individually. PID: 225.ppm FID: 225.ppm Tag: BLDG 19 Enter= Start log PID: 225.ppm FID: 225.ppm Sampling: 9sec Exit=Stop Run: Log F.E. Whenever the TVA-1000B is in the RUN mode with Log F.E. as the logging selection, the instrument logs its readings based on a pre-configured route file. NOTE: The operation of the Log F.E. mode is menu driven from the hand-held probe display and requires the use of the optional TVA-1000B Enhanced F.E. Probe. The procedure for using the TVA-1000B for Fugitive Emissions monitoring involves the following four steps: 1. Create a monitoring route using a Fugitive Emissions personal computer software program. 2. Download the route file to the TVA-1000B. 3. Log readings by following the monitoring route shown on the TVA-1000B display. 4. At the end of the monitoring route, upload the logged readings to the personal computer. 56 Display Menus MI 611-185 – June 1996 Using the Enhanced Probe This probe/display allows you to perform menu-driven operational/datalogging functions from the handheld unit and reduces the need to access the sidepack keypad. NOTE: In order to use the Enhanced Probe, be sure that the HARDWARE setting in the TVA-1000B SETUP menu is properly configured. There are three buttons on the Enhanced Probe which allow you to interact with the TVA-1000B: ♦ MENU – Used to cause the menu to appear on the bottom of the probe display and to step through the available selections ♦ SELECT – Used to choose the currently highlighted menu selection; e.g., “LOG”. ♦ Light Bulb Icon – Used to turn the display backlight on and off The Enhanced Probe and the RUN Mode 1. From the MAIN menu, press 1 = RUN. 2. The enhanced probe display will display the detector reading (FID or PID) at the top and an analog bargraph on the bottom. Press the MENU key on the Enhanced probe display to show the Opening menu: FID 5.70 ppm [ Enter logging mode ] - Ignite - Other det - Background - Exit The highlighted menu item is the item surrounded by brackets. Pressing the MENU key will cause the brackets to move from menu item to menu item. When you reach the menu item you wish to choose, press SELECT. The Opening menu items are as follows: Menu Item Function Enter logging Enters FE, VOC, or Auto logging mode, allowing you to enter tags, toggle mode through route files, log data, etc. If no logging is selected in the SETUP menu, then this selection does not appear. Ignite Ignites FID. This selection does not appear in PID-only models. Other det Toggles between FID and PID reading. This selection does not appear in single detector models. Background Records a new background reading. Exit Clears the menu and returns to the Bargraph display. 57 MI 611-185 – June 1996 Display Menus Auto Logging with the Enhanced Probe 1. In the RUN mode, press the MENU key to cause the menu to appear. Select “Enter logging mode.” 2. Use the sidepack or barcode reader to enter a tag, or simply select “Accept” to enter a blank tag. 3. Choose “Start log sampling” to begin Auto logging. 4. The Enhanced probe will display the countdown and continue to log until EXIT is selected at the probe or the sidepack keypad. 5. Once EXIT is selected, you may enter another tag and begin logging again or exit from the RUN mode. VOC Logging with the Enhanced Probe 1. In the RUN mode, press the MENU key to cause the menu to appear. Select “Enter logging mode.” 2. Use the sidepack or barcode reader to enter a tag, or simply select “Accept” to enter a blank tag. 3. Choose “Start log sampling” to begin Auto logging. 4. The Enhanced probe will display the count down for the interval selected in the SETUP menu and freeze on the reading to be saved (either the Maximum, Average, or Last Reading). 5. You may choose to save the reading (SAV), repeat the reading for the same tag (AGAIN), or return to the previous menu (EXIT). 6. Once you have saved a reading, you may enter another tag and begin logging again or exit from the RUN mode. FE (Fugitive Emissions) Logging with the Enhanced Probe In FE logging, you follow a preconfigured route list consisting of component records for equipment to be monitored. You should first download a route to the TVA-1000B’s memory before entering the RUN mode. For more information on downloading routes, see the PCLink section of the “Display Menus” chapter. In the RUN mode, press the MENU key to cause the menu to appear. Select “Enter logging mode.” The following display will appear on the Enhanced probe: FID 5.70 ppm Tag: 12345 Eqp: PMP Size: 2.500 Max: 1000 550 ppm LastLog [Start log sampling] - Next -Prev -Exit In addition to the concentration display at the top, the FE mode shows several fields which have been filled in by the downloaded route. The TVA-1000B starts at the first record in the 58 Display Menus MI 611-185 – June 1996 route and displays the component tag number (Tag), equipment type (Eqp), equipment size (Size), and leak definition (Max). If a reading has already been logged into memory for this record, it will also be displayed followed by the words “LastLog.” Route Entry Response Factor A secondary response factor correction is based on the response factor associated with the current route entry. This secondary correction adjusts the concentration reading for different component measurements in the same route. For example, let a route contain two entries, one for propane and one for methane. Assume that propane has only half the detector response of methane. If each route location has a leak of 100 ppm, a single response factor based on methane would produce a concentration reading of 100 ppm for methane, but only 50 ppm for propane. The addition of a secondary response factor allows each entry to be corrected for detector sensitivity. Thus, if the secondary response factor is 1.0 for methane and 2.0 for propane, both route samples will read correctly as 100 ppm. Only the linear correction mode is used for the secondary route response correction: Linear: FinalConc = RouteRF x BackConc The secondary RouteRF is downloaded to the instrument as part of each route entry. This factor is applied to both detectors, as it is expected that when operating in this mode, only one detector will be used. Entries inserted by the instrument default to a RouteRF of 1.0. Navigating the Route File Selecting “Next” from the first logging mode screen will allow you to step to the next record in the route. Selecting “Prev” will allow you to step to the previous record in the route. You can also enter a tag via the keypad or barcode scanner and the TVA-1000B will automatically skip to that tag if it is contained within the route. If the tag is not contained within the route, a “TAG NOT FOUND” message will appear and you will be given the option to “Insert” that tag into the route or “Exit.” Logging Data Once you have reached the correct tag for the component you wish to monitor, you may select “Start log sampling” to begin recording data. The TVA-1000B will display the readings from both detectors and begin counting down for the time interval selected in the SETUP menu. The countdown is shown on the last line of the display: 100.0 FID ppm Tag: 12345 Eqp: PMP Size: 2.500 Max: 1000 65.5 PID 100.0 FID Sampling: 5 s [Exit] 59 MI 611-185 – June 1996 Display Menus Once the countdown is complete, the TVA-1000B display will freeze on the reading to be logged and indicate if it is a leak (i.e., if the reading of the active detector exceeds the indicated leak rate). You will be given several options: FID 100.0 ppm Tag: 12345 Eqp: PMP Size: 2.500 Max: 1000 100.0 FID NoLeak - Repair [Sav] -Again -Exit If you choose “Sav”, the TVA-1000B will store the reading in memory (replacing any previously logged readings for that Tag) and proceed to the next component record in the route. If you choose “Again,” the TVA-1000B will repeat the countdown and obtain a new reading. If you choose “Exit” the TVA-1000B will return to the previous screen. Repair Menus If the reading obtained during the logging interval exceeds the leak definition, the TVA-1000B will indicate that it is a leak by printing “Leaker!” If you wish, you may record what part of the component is leaking and what action was taken as a first attempt at repair. Choose “Repair” instead of “Sav” and the TVA-1000B will proceed to the Repair menus: FID 100.0 ppm Leak Source: N/A Repair Method: N/A [Select leak source] -Select repair mthd -Exit The two lines below the reading show the currently selected leak source and repair method. Choosing “Select leak source” will allow you to record what part of the component is leaking by choosing from a list of leak sources (Valve Bonnet, Compressor Seal, Downstream Flange, Valve Packing, Pump Seal, Upstream Flange). Choosing “Select repair method” will allow you to record what method was used for the first attempt at repair (Place Cap, Gun Pack Valve, Place Plug, Repack Valve, Replace Gasket, Replace, Seal Job, Steam Seal, Tighten Bonnet, Tighten Cap, Tighten Flange, Tighten Packing, Tighten Plug, Wash Seal). Choosing “Exit” will return you to the previous display. If you choose a leak source and repair menu, be sure to select “Sav” when you return to this menu so the reading and repair information will be saved in memory before proceeding to the next component record. 60 Display Menus MI 611-185 – June 1996 Additional Component Information Displays containing additional information about the component and the TVA-1000B status are available from the handheld unit. If you press and hold the MENU key for approximately 2 seconds, the Enhanced display will present an INFO page: FID 5.70 ppm Tag: 12345 Eqp: PMP Size: 2.500 Loc: Plant1 Station2 Reagent feed pump downstream of vessel 17:33:51 [Pg] -Exit The INFO page overwrites the bottom four lines of the record with other fields such as Location (Loc) and Description (the two lines below the location). The Location field contains the Area and the Subarea where the component is located. The Description field displays up to 40 characters of additional information about the component. Selecting “Pg” at the bottom of the display will step you through other INFO pages containing information such as Run ID, Record number, number of points logged, number of leakers found, number of repairs performed, pump status, free memory, barcode reader status, etc. Selecting “Exit” will return you back to the normal component record. 61 MI 611-185 – June 1996 62 Display Menus Maintenance Removable, Renewable Parts WARNING: Parts replacement and maintenance should not be performed in areas classified as hazardous due to presence of flammable gases or vapors. Opening of the analyzer is not recommended under any circumstances, due to the intrinsic safety rating of the analyzer. Violation of this policy could void the warranty of this product. (Extended Service Plans are available; contact Foxboro Authorized Service for further information.) Foxboro suggests that you return the entire instrument to the factory or an authorized service center once a year for cleaning, testing, and calibration. Opening the TVA-1000B instrument case could void the warranty. From time to time, you must remove and renew several components of the TVA-1000B analyzer. Some components may be replaced as normal maintenance functions performed by operating personnel. Other components, however, should be replaced only by personnel thoroughly trained and familiar with the analyzer instrument and its applications. The components that may be maintained or replaced by operating personnel as part of normal operation are: 1. Battery – you may charge the battery in or out of the instrument or replace it with a charged battery. 2. Hydrogen Tank – remove the tank to refill it. 3. PID Cartridge – remove and clean frequently. Replace when needed. 4. FID Cartridge – remove and clean frequently. Replace when needed. 5. Close Area Sampler – replace if probe tip is clogged or damaged. 6. Filter Cups (in the sampler assembly and sidepack assembly) – clean/replace frequently. 7. Optional Water Trap – replace membrane or membrane support if worn or damaged. 8. Optional Charcoal Filter Adapter – replace charcoal frequently. 9. Sample Line Tubing – replace when dirty. 10. Sample Line Fitting – replace if damaged. 11. FID End Cap and Flame Arrestor – remove and clean frequently. Replace when required. 12. FID Cavity – clean periodically. 13. PID cavity – clean periodically. 63 MI 611-185 – June 1996 Maintenance WARNING: Never change an electrical component in an area classified as hazardous due to presence of flammable gases or vapors. Normal Operating Maintenance The items described in this section may be performed as normal operating procedures. Battery and Battery Charger WARNING: Do not remove or install batteries and do not use the battery charger in any area classified as hazardous due to the presence of flammable gases or vapors. The nickel cadmium battery, supplied with the unit, lasts for a minimum of eight hours of continuous use at 20 °C. Extreme heat or cold and/or use of the backlight, however, will shorten that time. A battery charger with cable is shipped with the instrument. You do not have to remove the battery for charging. Simply plug the output of the charger into the mating connector marked CHRG in the instrument. Then, insert the charger plug into the appropriate wall outlet. A green power indicator is ON when the charger is operating. A yellow indicator is activated when the charger is connected to the instrument and the instrument is ON. Normal charge time for a fully discharged battery is approximately 16 hours, or two hours of charge for every hour of use. Indicator Light Green Green Yellow Condition Indication ON Charger is plugged in and operating. OFF Charger is not plugged in. ON Charger is connected to the TVA-1000B and the TVA-1000B is ON while the charger is operating (i.e., trickle charging). Do not leave the battery on charge for extended periods (greater than 96 hours). If you wish to remove the battery from the TVA-1000B for charging or swapping with a spare battery, turn the instrument off. Using the special tool supplied with the accessory kit, unscrew the screw on the battery compartment cover on the rear of the instrument and remove the battery cover. As the battery pack fits snugly in the instrument housing, use care in removing the battery pack and its internal connector. As you remove the battery pack, note the location of the battery connector. When re-inserting the battery pack in the instrument, be sure to push the connector into the same location, so that it does not interfere with placement of the battery pack. To charge the battery outside of the unit, use the adapter supplied in the accessory kit. 64 Maintenance MI 611-185 – June 1996 Hydrogen Gas Tank FID instruments are supplied with an 85cc hydrogen gas tank. This tank, which may be pressurized to 2200 psi maximum at 25°C, will provide 8 hours operation when fully charged. The tank has an integrally mounted high pressure gauge that can be easily read when the tank is in or out of the instrument. Install the tank in the instrument by inserting it into the receptacle on the left side and tightening (left hand threads, tighten counterclockwise) until the rubber tank boot is flush with the instrument sidepack and a slight resistance is felt. Do not overtighten. Fuel Refilling Procedure WARNING: A safe refill operation means there are no hydrogen leaks. Before any valves are opened, use a wrench to firmly tighten connections to the hydrogen supply tanks and the tank fill adapter. If escaping hydrogen is heard during the filling operation, close all valves and correct the leak before proceeding. Leak test with soapy water or equivalent. NOTES: 1. Use prepurified ZERO grade hydrogen (certified total hydrocarbons as methane <0.5 ppm recommended). 2. The hydrogen filling assembly contains a flow-limiting safety device. Approximately two minutes are required to fill the tank. CAUTION: Do not fill hydrogen tank to a pressure greater than 15.2 MPa (2200 psig). Precautions in Handling and Storage The major hazard associated with the handling of hydrogen is flammability. The following specific rules apply when handling hydrogen: 1. Never use cylinders of hydrogen in areas where flames, excessive heat, or sparks may occur. 2. Use only explosionproof equipment and sparkproof tools in areas where hydrogen is handled. 3. Ground all equipment and lines used with hydrogen. 4. Never use a flame to detect hydrogen leaks — use soapy water. 5. Do not store reserve stocks of hydrogen with cylinders containing oxygen or other highly oxidizing or combustible materials. 6. Store hydrogen tanks in a well ventilated area. 7. Follow all regulatory safety and labeling precautions when shipping hydrogen in the TVA-1000B. 65 MI 611-185 – June 1996 Maintenance NOTE: A bleeder assembly is provided in the tool kit to allow the hydrogen tank to be emptied for common carrier shipment. To use the bleeder, manually screw the bleeder onto the tank valve and allow the hydrogen to vent. This process will take about two minutes to complete. CAUTION: Observe all hydrogen handling procedures listed above. When transporting the instrument, remove the hydrogen tank and place it in its normal location in the carrying case. To fill the tank, use the following procedure: NOTE: All hydrogen fittings are left hand thread — do not overtighten. 1. Turn supply tank valve OFF. 2. Attach tank fill adapter to supply tank with valve OFF and with manifold valve on OFF position. 3. Attach TVA-1000B hydrogen tank to tank fill adapter. (Note left hand thread — do not overtighten.) 4. Open supply tank valve. Move fill adapter valve to FILL position. 5. Wait for TVA-1000B tank to fill. This may take 2 to 3 minutes because of flow restrictors in the tank and fill adapter. 6. Close fill adapter valve. 7. Remove TVA-1000B tank. 8. Close supply tank valve. 9. Remove tank fill adapter. Always remove the tank from the instrument before storing in the instrument carrying case. Servicing the PID Cartridge To service the PID cartridge, use the following procedure: 1. Turn the instrument OFF. 2. Using the special spanner wrench provided with the instrument tool kit, unscrew the blue cap holding the PID cartridge in place. 3. Screw the special extractor tool provided with the accessory kit into the off-center hole in the cartridge. (Do not exceed three full turns. Refer to Figure 10.) 4. Remove the cartridge by pulling on the extractor. Unscrew the extractor from the cartridge. Clean or replace the cartridge. 5. To insert a new cartridge, reverse the procedure. Note that the standard 10.6 eV PID cartridge is marked with a blue band. Other energy level lamps are marked with different colors (not red). 66 Maintenance MI 611-185 – June 1996 For NORMAL periodic cleaning of a PID lamp window (other than an 11.8 ev lamp), use the following procedure: 1. Remove the cartridge from the instrument as described above. 2. Clean the lamp window using a cotton swab with isopropyl alcohol. 3. Using a heat gun, dry the cartridge for about 60 seconds to evaporate the alcohol. Reinsert the cartridge into the instrument. 4. Screw in the blue PID detector cap, using the special spanner wrench supplied with the tool kit. Do NOT overtighten cap. In cases where the lamp window is severely coated, refer to the procedure below for using the optional PID lamp cleaning kit. EXTRACTOR TOOL DETECTOR COLORED BAND (BLUE FOR PID 10.6 EV LAMP, RED FOR FID) Figure 10. PID Lamp Cleaning Kit To clean a PID lamp window with the optional PID lamp cleaning kit, use the following procedure: 1. Remove the cartridge from the instrument, as described above. 2. Clean the window of the lamp, using the materials suppled with the optional PID lamp cleaning kit. Follow the instructions included with the cleaning kit, being careful never to touch the window with your fingers. 3. When the cartridge is dry (dry at 40°C to 55°C for 1 hour), screw the extractor into the cartridge and re-insert it into the instrument. 4. Screw in the blue PID detector cap, using the special spanner wrench supplied with the tool kit. Do NOT overtighten cap. NOTE: Refer to MI 611-183 on proper cleaning techniques for an 11.8 eV lamp. Servicing an FID Cartridge To remove the FID cartridge, use the following procedure; 1. Close the hydrogen supply valve on the side of the instrument. Turn the instrument off. 2. Using the special spanner wrench provided with the instrument tool kit, unscrew the red cap holding the FID cartridge in place. 67 MI 611-185 – June 1996 Maintenance 3. Screw the special extractor tool provided with the accessory kit into the off-center hole in the cartridge (see Figure 10). 4. Remove the cartridge by pulling on the extractor. Unscrew the extractor from the cartridge. Clean or replace the cartridge. 5. To insert a new cartridge, reverse the procedure. Note that a FID cartridge is marked with a red band. To clean an FID cartridge, you will need a cotton swab and some isopropyl alcohol. Dip the swab into the isopropyl alcohol and insert it into the center of the cartridge. Swab the surface until clean and discard the swab. Take care not to touch the igniter coil, which is located close to the end of the capsule opposite the threaded hole used to remove capsule. Then dry the cartridge in an oven at 45°C to 55°C for one hour. When dry, re-insert the cartridge into the instrument, reversing the removal procedure. Do NOT overtighten cap. CAUTION: Do not allow any contact with the igniter coil during cleaning. Cleaning the FID Detector Cap To clean the FID detector end cap, use the following procedure: 1. Close the hydrogen supply valve on the side of the instrument and turn off the power. 2. Using the special spanner wrench provided with the tool kit, unscrew and remove the FID red detector cap. 3. Clean the cap using the isopropyl alcohol followed with a deionized or distilled water rinse. Blow out carefully with compressed dry air. 4. Replace the cap. Replacing the Flame Arrestor The flame arrestor, located in the center of the red FID end cap, can be either cleaned or replaced. To replace the flame arrestor, use the following procedure: 1. Close the hydrogen supply valve on the side of the instrument and turn off the power. 2. Using the special spanner wrench provided with the tool kit, unscrew and remove the FID red detector cap. 3. Remove spring. 4. Place the detector cap on a flat surface, face up. 5. Place a screwdriver through the center hole of the end cap, resting on the flame arrestor. 6. Strike the end of the screwdriver with a hammer to drive the old flame arrestor out of the end cap. 7. Remove the old flame arrestor. 68 Maintenance MI 611-185 – June 1996 8. Turn the end cap over so the red outer surface lies flat and the gray surface faces up. 9. Place the new flame arrestor in the center hole. 10. Place a screwdriver on the newly installed flame arrestor. 11. Strike the end of the screwdriver with a hammer to secure the new flame arrestor in place. 12. Replace the spring. 13. Replace the detector cap on the unit. Cleaning the FID or PID Detector Cavities 1. Close the hydrogen supply valve on the side of the instrument. Turn the instrument off. 2. Using the special spanner wrench provided with the tool kit, unscrew the cap holding the respective detector cap. 3. Using the special extractor tool provided with the tool kit, screw the extractor into the cartridge. 4. Remove the cartridge by pulling on the extractor. Unscrew the extractor from the cartridge. 5. Carefully clean the inside of the detector cavity using a cotton swab and isopropyl alcohol. Be sure to clean the high voltage contacts along the side of the cavity. Be especially careful around the detector signal collector probe at the rear of the cavity (and the thermocouple probe in the FID). 6. Dry the inside of the cavity using a low heat gun. 7. Insert the cartridges into their respective cavities by reversing the procedure. Note that the cartridges must be rotated to properly locate the key tabs. CAUTION: Do not intermix the detector cartridges. Cleaning or Replacing a Sintered Metal Filter To remove the sintered metal filter cup from the close area sampling assembly, simply unscrew the cap from the sampler and tip the assembly so that the filter falls out. The same filter cup and spring are also located behind the sample line quick connect at the sidepack assembly. To remove, unscrew the quick connect so that the filter falls out. The internal spring will not fall out. Refer to the assembly diagram below. You may clean the filter by immersing it in isopropyl alcohol or equivalent solvent and/or swabbing the surface with a Q-tip or cotton swab. After thoroughly cleaning the surface of the filter, place the filter in an oven and dry it at 40 °C to 55 °C for one hour. You can then reinsert the filter into the sampling assembly (with the closed end of the filter in first) and screw in the cap. 69 MI 611-185 – June 1996 Maintenance SPRING SINTERED METAL FILTER CAP Figure 11. Sintered Metal Filter - Cleaning or Replacing Replacing Sample Line To replace the sample line, refer to Figure 12 below and execute the following procedure: 1. Loosen the probe nut and remove the sampling assembly by pulling it free from the probe assembly. 2. Insert a thin rod through the hole in the side of the probe fitting adapter. You will use this rod to pull the adapter and tubing from the probe assembly. 3. Remove the tubing from the quick-connect fitting by pressing firmly on the ring at the back of the fitting (a tool may be necessary) while pulling on the tubing. 4. At the base of the probe handle, gently push the tubing into the probe. At the same time, use the rod to pull the probe fitting adapter and tubing forward from the probe assembly. When the adapter fitting is fully exposed, cut the tubing from the fitting and pull the remainder of the tubing back through the probe assembly until it is completely out of the probe. 5. Cut a new piece of tubing about three inches longer than the old tubing. 6. Insert new tubing through the bottom protective covering (where you connect to the analyzer), and slowly feed the tubing through toward readout handle. 7. Once the tubing exits the top protective covering, insert the new tubing into the probe handle and carefully push it through to the other end. When the tubing is in position, cut the end square and push it over the barbed adapter fitting. (Heating the tube end may aid in fitting the tubing over the adapter.) 8. Grasp the tubing below the probe assembly handle and pull it back through the probe assembly until the adapter fitting is properly seated in the probe assembly. 9. Cut the other end of the tubing to the proper length and insert it into the end of the quick-connect fitting. (Allow 5/8-inch of tubing inside the fitting.) 70 Maintenance MI 611-185 – June 1996 PROBE NUT PROBE FITTING ADAPTER PROBE ASSEMBLY HANDLE QUICK-CONNECT QUICK-CONNECT ELECTRICAL FITTING UMBILICAL WITH SPIRAL WRAP (OR OUTER TUBING) Figure 12. Replacing Sample Line 71 MI 611-185 – June 1996 72 Maintenance Troubleshooting Problem Unit will not turn on Pump won’t turn on Low pump flow Possible Reason Battery charge low Solution/Action Charge battery. Bad battery connection Ensure proper battery connection. Bad battery Replace battery. Blown fuse or faulty keypad Defective pump Faulty keypad Clogged sample intake Contact TEI authorized service center. Contact TEI authorized service center. Pump fault Faulty keypad Contact TEI authorized service center. Contact TEI authorized service center. Hydrogen valve off Turn on hydrogen supply valve and allow 1-2 minutes before igniting. Insufficient hydrogen supply (<500 psi) Check hydrogen gauge on supply tank. Refill tank if necessary. Hydrogen leak Check low pressure hydrogen output gauge. If <10.5 psi, contact TEI authorized service center. Broken igniter Inspect igniter coil on FID capsule for breakage. If broken, replace capsule. Dirty igniter contacts Inspect/clean igniter contacts (NOT igniter coils). Battery charge low Charge battery pack. Clean/replace filter cups. Clean/replace sample line. Clean/replace flame arrestor. Keypad will not respond Probe display blank or Faulty probe/display assembly Replace probe/display assembly. probe buttons will not Contact TEI authorized service center. respond Turn pump on. FID won’t ignite Insufficient sample flow Clean/replace filter cups. Clean/replace flame arrestor. 73 MI 611-185 – June 1996 Problem FID noisy Troubleshooting Possible Reason Water/contamination in the detector chamber Erratic pump flow Solution/Action Clean/replace FID capsule and flame arrestor. Clean/replace filter cups. Clean/replace flame arrestor. Ensure proper calibration. Unable to calibrate FID Bad calibration FID flame out Ignite FID. Span concentration not prop- Input correct span gas concentration at CAL erly set menu. Cal gases contaminated Use clean cal gases and sampling equipment. Sample line/filter cups contaminated Clean/replace sample line. Clean/replace filter cups. FID capsule contaminated or Clean/replace FID capsule. faulty Contaminated hydrogen tank Replace hydrogen tank. Excessive hydrogen consumption (<8 hours of run time for 2200 psi hydrogen) Flameout problems Internal detector fault or con- Contact TEI authorized service center. tamination Insufficient hydrogen pressure Refill tank. Leaking hydrogen tank Replace tank. Internal hydrogen leak Sample hydrocarbon content too high Contact TEI authorized service center. Use dilutor kit to achieve concentration within the dynamic range of the TVA. Insufficient oxygen in the sample (<14%) Use dilutor kit to dilute sample with air containing sufficient oxygen. Use PID for measurements. FID capsule contamination Clean/replace FID capsule. Insufficient sample flow Clean/replace filter cups. Clean/replace flame arrestor. Clean/replace filter cups. Clean/replace flame arrestor. Moisture at FID flame Insufficient sample flow arrestor NOTE: Normal operation produces some moisture. If performance is affected, attempt these solutions. 74 Insufficient warmup time Allow 15-20 minutes warmup. Troubleshooting MI 611-185 – June 1996 Problem Possible Reason PID lamp not operat- Bad PID lamp ing PID noisy Bad PID lamp Unable to calibrate PID Solution/Action Replace PID capsule. Replace PID capsule. Dirty PID window Clean PID window. Erratic pump flow Clean/replace filter cups. Clean/replace flame arrestor. Bad calibration Pump not on Ensure proper calibration. Turn pump on. PID lamp not on Turn PID lamp on. Span concentration not prop- Input correct span gas concentration at CAL menu. erly set Slow response time High background readings Cal gases contaminated Use clean cal gases and sampling equipment. Sample line/filter cups contaminated Clean/replace sample line. Clean/replace filter cups. PID window dirty or capsule contaminated or faulty Clean PID window. Replace PID capsule. Internal detector fault or con- Contact TEI authorized service center. tamination Insufficient sample flow Clean/replace filter cups. Clean/replace flame arrestor. Clean/replace sample line. Sampling non-volatile compounds High ambient concentration Contact TEI Applications Laboratory. Zero drift/improper calibration Ensure proper zero/span calibration. Sample line contamination Clean/replace sample line. Clean/replace filter cups. Detector capsule contamination Clean/replace FID capsule. Clean PID window. Replace PID capsule. N/A. 75 MI 611-185 – June 1996 Troubleshooting Warning Messages Message =WARNING== = Battery Power is low. Exit=Clr = = = WARNING= Pump must be on to select mode. Exit=Clr =WARNING== Logger memory is already full. Exit=Clr This display occurs whenever the battery has reached a low level (approximately 6.0 V). It indicates that approximately 15 minutes of operating time remain. Press EXIT to return to the operating display. The lower right corner of all displays now show ± (blinking). If you continue to operate after the warning is displayed, the unit will eventually shut off automatically. To restart after an auto shut down, you must first recharge or replace the battery. Note that collected data is not lost This display occurs when the pump is not on for a function that requires the pump to be on. Log memory is full. You cannot continue to log any entries until you have transferred the log memory to a PC or have cleared log memory. The instrument will, however, continue to operate. =WARNING== FID flameout! Ignite again. Exit=Clr This display appears whenever the FID flame is extinguished. Press EXIT to clear, then CONTROL key and 2 to ignite. This warning is active only in RUN and CALIBRATE modes. In the RUN mode, once the alarm is acknowledged, a flashing F appears on the sidepack display and the probe display flashes. =WARNING== PID lamp not operating Exit=Clr This message indicates that the PID lamp activity is low. Check lamp and re-zero the PID. This warning is active only in RUN and CALIBRATE modes. In the RUN mode, once the alarm is acknowledged, a flashing P appears on the sidepack display and the probe display flashes. =WARNING== Log rate too slow for PC STEL calc Exit=Clr 76 Description This message appears whenever you enter a log rate value greater than 90 seconds. The data sampling rate is too low for valid STEL calculations in the PC. Press EXIT to bypass the warning. Troubleshooting MI 611-185 – June 1996 Message =WARNING== Log rate invalid! Exit=Clr WARNING== Entry is invalid! Exit=Clr WARNING== Bad Calibration parameters! Exit=Clr = Hardware Failure WARNING== PID lamp must be ON to continue Exit=Clr Description This message appears whenever you enter a log rate of zero. To correct the problem, enter a log rate other than zero. This message appears whenever you enter a value equal to zero (except for alarm levels). To correct the problem, enter numbers other than zero. This warning display appears during calibration if the current zero calibration value equals or exceeds the span calibration value. To correct the problem, perform a re-zero, a re-span, or both. This message appears as a result of a self-test failure. Return the instrument to the factory for service. The PID has been turned OFF. To continue, use the Control Menu to turn the PID on. 77 MI 611-185 – June 1996 78 Troubleshooting Accessories Telescoping Extension Option To use an optional telescoping extension, loosen the probe nut and unplug the sampling assembly. Next, insert the telescoping wand and tighten the probe nut. Then, insert the appropriate sampling assembly into the other end of the extension unit and tighten the retaining nut. PROBE ASSEMBLY PROBE NUT CLOSE AREA SAMPLER FILTER ADAPTER TELESCOPING EXTENSION UNIT Figure 13. Telescoping Extension Option Activated Charcoal Filter Adapter The Activated Charcoal Filter Adapter is an accessory that can be installed or attached to the end of the standard probe or to the end of a telescoping extension. The filter is typically filled with activated charcoal which acts as an adsorbent and effectively filters out organic vapors other than methane or ethane. A screw cap on the probe end may be removed for refilling the filter with activated charcoal or other filtering medium. Applications of the filter include: 1. Obtaining a clean air sample for zero baseline check and adjustment. 2. Rapid screening of methane and non-methane organic vapors. 3. Selective screening for natural gas surveys. The charcoal filter adapter fits directly into the telescoping wand. The life of the filter depends on the time in use, the types of compounds, and concentrations of the compounds being filtered. Under typical industrial air monitoring conditions, the filter will last for many days of continuous sampling. 79 MI 611-185 – June 1996 Accessories To replace charcoal in a charcoal filter, use the following procedure: 1. Remove the sampling assembly from the probe by loosening the probe nut and pulling the sampling assembly free from the probe. 2. Unscrew the cap from the sampling assembly. This will expose the end of the charcoal filter cartridge. See diagram below. 3. Tip the cartridge up and empty the charcoal from the cartridge. 4. Clean the inside of the cartridge with a cotton swab dipped in isopropyl alcohol. 5. Dry the cartridge thoroughly. 6. Re-fill the cartridge with new “dust-free” charcoal of the type specified for the filter. 7. Apply Teflon tape to the male threads of the charcoal cartridge and screw on the cap. 8. Re-insert the sampling assembly into the probe and tighten the probe nut. CARTRIDGE FILLED WITH ACTIVATED CHARCOAL THREADED END WITH TEFLON TAPE CAP Figure 14. Activated Charcoal Filter Adapter For information on additional accessories, such as calibration kits, enhanced probes, barcode readers, optional energy lamps (PID), or dilutor kits, please contact TEI. 80 Appendix A: Text Data Formats Route List File Format The route list format is as follows: Format ROUTE LIST VER=x.x RUN ID=aaaa END Comments Title, not processed x=0-9 a=0-9, A-Z, a-z Blank line, not processed Blank line, not processed See route entry header below: not processed See route entry header below: not processed See route entry header below: not processed See route entry below Blank line, not processed Marks end-of-text The first eight lines of the route list constitute the route header. The last three lines of the route header are composed of text column headers (route entry header lines 1 and 2) and an underline of dashes (route entry header line 3). The route entry headers are specified below by specification of header text for lines 1 and 2 and starting position (all other characters blank spaces, not tabs). Line 3 is a dash character ‘-’ for all route entry characters except the delimiter (space instead). The route entry header format is as follows: Start 0 17 26 35 41 46 50 57 105 106 Header Line 1 Header Line 2 TAG AREA SUBAREA RATE FACT TYP SIZE LEAK RESP EQP EQUIP DESCRIPTION The remaining lines in the route list are route entries. Each route entry consists of tag, area, subarea, leak rate, response factor, equipment type, equipment size, and description. The route entry format is as follows: Byte 0 16 17 25 26 34 35 40 41 45 46 49 50 56 57 105 106 Length 16 1 8 1 8 1 5 1 4 1 3 1 6 1 48 1 1 Item Tag delimiter Area delimiter Subarea delimiter Leak rate delimiter Response factor delimiter Equipment type delimiter Equipment size delimiter Description Format text space text space text space floating point space floating point space text space text space text 0DH 0AH 81 MI 611-185 – June 1996 Appendix A: Text Data Formats NOTE: Downloaded route entries may be terminated any time after the tag by the . Partial text entries are processed as ending in trailing spaces. Partial number entries are processed as if complete. The default value for fields not included in the entry are: Default Field Area all spaces Subarea all spaces Leak rate 0.0 Response factor 1.0 Equipment type all spaces Equipment size all spaces Description all spaces Sample Route List File ROUTE LIST VER= 1.00 RUN ID=0001 TAG ---------------1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 AREA -------AREA1 AREA2 AREA3 AREA4 AREA5 AREA6 AREA7 AREA8 AREA9 AREA10 AREA11 AREA12 AREA13 AREA14 AREA15 AREA16 AREA17 AREA18 AREA19 AREA20 AREA21 AREA22 AREA23 AREA24 AREA25 SUBAREA -------SUBAREA1 SUBAREA2 SUBAREA3 SUBAREA4 SUBAREA5 SUBAREA6 SUBAREA7 SUBAREA8 SUBAREA9 S-AREA10 S-AREA11 S-AREA12 S-AREA13 S-AREA14 S-AREA15 S-AREA16 S-AREA17 S-AREA18 S-AREA19 S-AREA20 S-AREA21 S-AREA22 S-AREA23 S-AREA24 S-AREA25 LEAK RATE ----0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5000 99999 10000 40000 50 RESP FACT ---1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.00 5.00 .001 .01 0.01 .1 00.1 1 10 100 1000 EQP TYP --N/A BON CSL DFL PKG PSL RPL VLV FLG FLG VLV PRV VLV CMP VLV VLV VLV FLG FLG VLV VLV VLV VLV FLG VLV EQUIP SIZE -----1.00 0.50 1.75 10.00 5.50 0.25 950.50 0.25 0.75 0.75 0.75 1.50 0.75 0.00 0.75 0.75 1.50 1.50 0.75 0.75 0.75 0.75 0.75 0.50 0.75 DESCRIPTION ----------DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 END Configuration File Format The configuration format is as follows (options are separated by a '|'): Format CONFIGURATION VER=X.X MODEL=xxxxxxxxxx SERIAL NUMBER=ididididid DETECTOR=PID|FID|PID&FID OPERATOR ID=opopopopop LOGGING ------- LOG MODE=NONE|AUTO|VOC|FE|CUSTOM LOG AUTO REPEAT=OFF|ON LOG UNIT LOCK=OFF|PPB|PPM|PERCENT LOG SAVE MODE=MANUAL|AUTO LOG STORAGE FORMAT=NONE|FOXAUTO|FOXVOC|FEVOC LOG SAMPLE TIME=nnnnn 82 Appendix A: Text Data Formats MI 611-185 – June 1996 LOG SAMPLE TIME UNIT=SEC|MIN LOG DATA STORED=SAMPLE|AVERAGE|MAXIMUM BARCODE VERIFY=OFF|ON ROUTE ACTIVE=OFF|ON TAG ACTIVE=OFF|ON CALIBRATION ----------- CAL AUTO ACCEPT=OFF|ON CAL AUTO SAVE=OFF|ON CAL UNIT LOCK=OFF|PPB|PPM|PERCENT CAL NUM SPAN POINTS (PID)=n CAL SPAN PT 1 (PID)=ffffff PPB|PPM|PERCENT CAL SPAN PT n (PID)=ffffff PPB|PPM|PERCENT CAL NUM SPAN POINTS (FID)=n CAL SPAN PT 1 (FID)=ffffff PPB|PPM|PERCENT CAL SPAN PT n (FID)=ffffff PPB|PPM|PERCENT BACKGROUND CORRECTION (PID)=OFF|ON BACKGROUND CORRECTION (FID)=OFF|ON RESPONSE FACTORS ---------------- SELECTED=n MODE=FACTOR|CURVE RF1 (PID) nnnnnnnnnn xx.xx + yy.yy RF9 (PID) nnnnnnnnnn xx.xx + yy.yy RF1 (FID) nnnnnnnnnn xx.xx + yy.yy RF9 (FID) nnnnnnnnnn xx.xx + yy.yy ALARMS ------ HIGH (PID)=ffffff PPB|PPM|PERCENT LOW (PID)=ffffff PPB|PPM|PERCENT STEL (PID)=ffffff PPB|PPM|PERCENT HIGH (FID)=ffffff PPB|PPM|PERCENT LOW (FID)=ffffff PPB|PPM|PERCENT STEL (FID)=ffffff PPB|PPM|PERCENT USER OPTIONS ------------ BARCODE READER=NONE|HP|PSC DIGITAL DATA LOGGING=NONE|FID&PID|PPM DISPLAY DELAY=SHORT|MEDIUM|LONG KEY CLICK=OFF|ON PC LINK TYPE=FOXBORO|FEMS|TEXT-MANUAL|TEXT-AUTO PROBE=BASIC|ENHANCED END NOTES: 1. Lines containing information on uninstalled detectors (PID) or (FID) are not output. 2. Spaces are allowed in names and other text fields entered by the user. 3. Number fields are right justified, leading spaces. 4. The second detector repeats the RF names. During download, the last RF name encountered is used. Sample Configuration File CONFIGURATION VER= 1.00 MODEL=TVA-1000B SERIAL NUMBER=000007156962 DETECTOR=PID&FID OPERATOR ID=USERID LOGGING ------LOG MODE=NONE LOG STORAGE FORMAT=NONE LOG SAMPLE TIME=0 LOG SAMPLE TIME UNIT=SEC LOG DATA STORED=SAMPLE LOG UNIT LOCK=OFF LOG AUTO REPEAT=OFF LOG SAVE MODE=MANUAL TAG ACTIVE=OFF ROUTE ACTIVE=OFF BARCODE VERIFY=OFF CALIBRATION ----------- 83 MI 611-185 – June 1996 Appendix A: Text Data Formats CAL AUTO ACCEPT=OFF CAL AUTO SAVE=OFF CAL UNIT LOCK=OFF BACKGROUND CORRECTION (PID)=ON BACKGROUND CORRECTION (FID)=ON RESPONSE FACTORS ---------------SELECTED=0 MODE=FACTOR RF0 (PID)=DEFAULT RF1 (PID)=---------RF2 (PID)=---------RF3 (PID)=---------RF4 (PID)=---------RF5 (PID)=---------RF6 (PID)=---------RF7 (PID)=---------RF8 (PID)=---------RF9 (PID)=---------RF0 (FID)=DEFAULT RF1 (FID)=---------RF2 (FID)=---------RF3 (FID)=---------RF4 (FID)=---------RF5 (FID)=---------RF6 (FID)=---------RF7 (FID)=---------RF8 (FID)=---------RF9 (FID)=---------ALARMS -----STEL (PID)= LOW (PID)= HIGH (PID)= STEL (FID)= LOW (FID)= HIGH (FID)= 0.00 0.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 PPM PPM PPM PPM PPM PPM USER OPTIONS -----------PROBE=BASIC BARCODE READER=NONE KEY CLICK=OFF DISPLAY DELAY=MEDIUM PC LINK TYPE=TEXT-AUTO DIGITAL DATA LOGGING=NONE END Calibration File Format The calibration header format is as follows: Format CALIBRATION DATA VER=x.x END Comments Title, not processed x=0-9 Blank line, not processed Blank line, not processed PID if available, see below FID if available, see below Marks end-of-text The calibration data format is as follows (note: from 1 to 9 span gas points are allowed): ddd CALIBRATION: CALIB KNOWN CALIB TYPE CONC DATE/TIME ----- ---------- -----------------ZERO aaaaaa uuu dd mmm yy hh:mm:ss SPAN1 aaaaaa uuu dd mmm yy hh:mm:ss . . . . . . . . . . . . . . . . . . . . . . . . . . . SPANn aaaaaa uuu dd mmm yy hh:mm:ss where: ddd = detector type “FID” “PID” MEASURED CALIB VALUE ------------------------- bbbbbbbb COUNTS fffffffff bbbbbbbb COUNTS fffffffff . . . . . . bbbbbbbb COUNTS fffffffff aaaaaa = gas concentration, floating point, right justified, leading spaces uuu = concentration units: “PPB”, parts-per-billion 84 Appendix A: Text Data Formats MI 611-185 – June 1996 “PPM”, parts-per-million “%” , percent dd = day of calibration, 01-31 mmm = month of calibration, Jan-Dec yy = year of calibration, 00-99 hh = hour of calibration, 00-23 mm = minute of calibration, 00-59 ss = second of calibration, 00-59 bbbbbbbb = detector reading for calibration gas, integer, right justified, leading spaces fffffffff = count status: “OK” , no errors “DET_OFF”, detector reading invalid “DET_FAIL”, detector failed, not invalid “OVERFLOW”, A/D overflow, not invalid “UNDERFLOW”, A/D underflow, not invalid or A/D overflow n = span gas number, 2-9 Sample Calibration File (Dual Detectors) CALIBRATION DATA VER= 1.00 PID CALIBRATION: CALIB TYPE ----ZERO SPAN1 KNOWN CONC ---------0 PPB 0 PPB CALIB DATE/TIME ------------------01 JAN 80 00:00:00 01 JAN 80 00:00:00 MEASURED CALIB VALUE ------------------------0 COUNTS OK 0 COUNTS OK CALIB DATE/TIME ------------------01 JAN 80 00:00:00 01 JAN 80 00:00:00 MEASURED CALIB VALUE ------------------------0 COUNTS OK 0 COUNTS OK FID CALIBRATION: CALIB TYPE ----ZERO SPAN1 KNOWN CONC ---------0 PPB 0 PPB END Logged Data File Format (Upload Only) The logged data format is as follows: Format LOGGED DATA VER=x.x . . . END Comments Title, not processed x=0-9 Blank line, not processed See below Blank line, not processed Marks end-of-text The logged data record is different for each data storage type. A header is printed whenever the data storage type changes. The data type records are: Auto logged header and data, single detector: AUTO DATA DATE --------dd mmm yy tttttttttttttttt TIME CONCENTRATION -------- -------------------- hh:mm:ss xxxxxx uuu fffffffff 85 MI 611-185 – June 1996 Appendix A: Text Data Formats Auto logged header, dual detector: AUTO DATA DATE --------dd mmm yy tttttttttttttttt TIME PID CONCENTRATION -------- -------------------hh:mm:ss xxxxxx uuu fffffffff FID CONCENTRATION -------------------- xxxxxx uuu fffffffff VOC logged header and data, single detector: VOC DATA DATE TIME --------- -------dd mmm yy hh:mm:ss TAG ---------------tttttttttttttttt CONCENTRATION -------------------- xxxxxx uuu fffffffff VOC logged header and data, dual detector: VOC DATA DATE TIME --------- -------dd mmm yy hh:mm:ss TAG ---------------tttttttttttttttt PID CONCENTRATION -------------------xxxxxx uuu fffffffff FID CONCENTRATION -------------------- xxxxxx uuu ffffffff FE logged header and data: FE DATA DATE TIME --------- ---------- dd mmm yy hh:mm:ss RRRRR where: ttt... = tag TAG DET ---------------- LEAK REPAIR