100% F140643 Q SJT ZJCZ(105C,VW 1,FT1,18AWG) Report
2016-09-21
: Pdf report Report VendorTechDocs 328289 ProductFiles
Open the PDF directly: View PDF .
Page Count: 14
Download | |
Open PDF In Browser | View PDF |
Project No. F140643 LABORATORY DATA PACKAGE File E313867 Page 1 of 14 The wire should be 18AWG confirmed with IC. ULS-00062-ZJCZ-DataSheet-2001 Form Page 1 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 LABORATORY DATA PACKAGE File E313867 Page 2 of 14 Number of pages in this package _14___ (Fill in when using printed copy as record) CLIENT INFORMATION Manufacturer NINGBO XUANHUA ELECTRIC CO LTD Name 100030-765 Manufacturer Subscriber No. AUDIT INFORMATION: [X] Description Per of Tests Standard No. [ ] Tests Conducted by + [] UL Staff conducting or witnessing testing (WTDP, TMP, WMT only) [] UL Staff supervising UL Staff in training [] Authorized Signatory (CTDP, TPTDP, TCP, PPP, SMT) Reviewed and accepted by qualified Project Handler ULS-00062-ZJCZ-DataSheet-2001 Form Page 2 [X] UL 62 Edition/ Revision date Nineteenth/ 2014-03-14 [] UL 2556 Third/ 2013-03-22 [X] CSA C22.2 No. 49 Fourteenth/ 2014-03 [] UL 507 Ninth/ 2010-04-20 [] UL 1042 Fifth/ 2010-06-16 [] UL 1278 Third/ 2010-06-16 - - Printed name Signature - - Printed name Signature. Include date for CTDP, TPTDP, TCP, PPP, WMT, TMP, SMT - Jessie Wu Printed Name Signature Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 LABORATORY DATA PACKAGE File E313867 TESTS TO BE CONDUCTED: Test Done No. +++ Test Name 1 X PHYSICAL PROPERTIES Page 3 of 14 [] Comments/Parameters [X]Tests Conducted by ++ Jerry Shen/ Jerry Shen 2 X MECHANICAL STRENGTH Randy Wang/ Randy Wang 3 X VERTICAL FLAME TEST - VW-1 OR FV2 Randy Wang/ Randy Wang 4 X VERTICAL FLAME TEST - FT1 OR FV1 Randy Wang/ Randy Wang ULS-00062-ZJCZ-DataSheet-2001 Form Page 3 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 LABORATORY DATA PACKAGE File E313867 Page 4 of 14 Instructions + - When all tests are conducted by one person, printed name and signature can be inserted here instead of including printed name and signature on each page containing data. Must indicate number of pages in the data package. ++ - When test conducted by more than one person, printed name and signature of person conducting the test can be inserted next to the test name instead of including printed name and signature on each page containing data. Test dates may be recorded here instead of entering test dates on the individual datasheet pages. Must indicate number of pages in the data package. +++ - Use of this field is optional and may be employed differently. If used to include a date instead of entering the testing date on the individual datasheet pages, the date shall be the date the test was conducted. Special Instructions [x] It shall be permitted to use a mandrel with a smaller size for heat shock, cold bend & flexibility test. If nonconforming results are obtained, a mandrel as specified on these data sheets shall be used. Unless specified otherwise in the individual Methods, the tests shall be conducted under the following ambient conditions. Confirmation of these conditions shall be recorded at the time the test is conducted. Ambient Temperature, C 23±5 Relative Humidity, % <70 Barometric Pressure, mBar N/A [x] No general environmental conditions are specified in the Standard(s) or have been identified that could affect the test results or measurements. Refer to individual test method for the requirement of ambient condition. RISK ANALYSIS RELATED TO TESTING PERFORMANCE: The following types of risks have been identified. Take necessary precautions. This list is not all inclusive. [ ] Electric shock [ ] Radiation [ ] Energy related hazards [ ] Chemical hazards [X] Fire [X] Noise [X] Heat related hazards [ ] Vibration [X] Mechanical [X] Other (Specify)occupational injury To Lab Staff: Refer to the below table for the unit conversion on the following datasheet. 1 mm = 0.03937 inch 1 KN = 224.8089lbf ULS-00062-ZJCZ-DataSheet-2001 Form Page 4 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Page Tested by: 5 of 14 Date Printed Name Signature TEST LOCATION: (To be completed by Staff Conducting the Testing) [X] UL or Affiliate [] WTDP [] CTDP [] TPTDP [] WMT [] TMP Company Name [] SMT UL-CCIC Company Limited 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122, China Address TEST EQUIPMENT INFORMATION Inst. ID No. Instrument Type Test Number +, Test Title or Conditioning Function /Range Last Cal. Date Next Cal. Date - - - - - - + - If Test Number is used, the Test Number must be identified on the data sheet pages or on the Data Sheet Package cover page. The following additional information is required when using client’s or rented equipment, or when a UL ID Number for an instrument number is not used. The Inst. ID No. below corresponds to the Inst. ID No. above. Inst. ID No. - Make/Model/Serial Number/Asset No. - [x] UL test equipment information is recorded on Meter Use in UL’s Laboratory Project Management (LPM) database. TEST SAMPLE IDENTIFICATION: The table below is provided to establish correlation of sample numbers to specific product related information. Refer to this table when a test identifies a test sample by "Sample No." only. Sample Card No. 1865376 Date Received [X] Test No. Sample No. 2014-04-29 1-4 W1-W16 Manufacturer, Product Identification and Ratings Referred to the attached sample tag + - If Test Number is used, the Test Number or Numbers the sample was used in must be identified on the data sheet pages or on the Data Sheet Package cover page. [] Sampling Procedure – [] This document contains data using color and if printed, should be printed in color to retain legibility and the information represented by the color. ULS-00062-ZJCZ-DataSheet-2001 Form Page 5 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Printed Name Page 6 of 14 Date 2014-05-13~ 2014-05-21 Signature PHYSICAL PROPERTIES: UL 62 and CSA C22.2 No. 49, Clauses 5.1.1 Sample Card No.: 1865376 Material: PVC Ins/Jkt: Ambient Temp.: Sample No.: W1 Ins. Color: Black Humidity: 23°C 55% RH Ambient Temperature Requirement : 24 ± 8 °C Sample Type: [x] Insulation [ ] Jacket Sample Preparation: [x] Tubular [ ] Die Cut [ ] Buffed Speed of Separation: 20 Inches Per Minute Actual Speed of Separation: 20 Inches Per Minute [ ] Planed Conditioning: [X] Unaged Specimen No. 1 2* 3* 4* 109.1 - - - 51.3 - - - - - - - 17.85 - - - 2450.8 - - - Bench marks broke at, in. 3.87 - - - Elongation, percent 287 - - - Results Results of * 2450.8 - Min. 1500 287 - Min. 100 O.D., mils. Cond dia, mils. 2 Area, in Peak load, lbf Tensile strength, lbf/in 2 2 Average tensile strength, lbf/in Average elongation, percent All Specimens were broken within gauge mark. ULS-00062-ZJCZ-DataSheet-2001 Form Page 6 J.S. Requirement 2014-05-21 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Printed Name Page 7 of 14 Date 2014-05-13~ 2014-05-21 Signature PHYSICAL PROPERTIES: (CONT’D) UL 62 and CSA C22.2 No. 49, Clauses 5.1.1 Sample Card No.: 1865376 Material: PVC Ins/Jkt: Ambient Temp.: Sample No.: W2.W3 Ins. Color: Black Humidity: 23°C 55% RH Conditioning: [X] After 7 [ ] After Days In Air Oven at 136 °C Hrs / Days in IRM902 Oil at _____ °C Test Start Date/Time: 2014-05-13/17:00 Test End Date/Time: 2014-05-20/17:00 Actual Aging Temperature: 136°C Specimen No. 1 2 3* 4* 5* O.D., mils. 109.1 109.1 - - - Cond dia, mils. 51.3 51.3 - - - - - - - - 18.83 19.07 - - - 2586.2 2618.7 - - - Bench marks broke at, in. 3.61 3.24 - - - Elongation, percent 261 224 - - - Area, in2 Peak load, lbf Tensile strength, lbf/in 2 Results Results of * Requirement 2602.5 - -- Percent of original 106.2 - Min. 85 Average elongation, percent 242.5 - -- Percent of original 84.5 - Min. 65 Average tensile strength, lbf/in 2 All Specimens were broken within gauge mark. ULS-00062-ZJCZ-DataSheet-2001 Form Page 7 J.S. 2014-05-21 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Printed Name Page 8 of 14 Date 2014-05-13~ 2014-05-21 Signature PHYSICAL PROPERTIES: UL 62 and CSA C22.2 No. 49, Clauses 5.1.2 Sample Card No.: 1865376 Material: PVC Ins/Jkt: Ambient Temp.: 23°C Sample No.: W4 Jkt. Color: Humidity: Black 55% RH Ambient Temperature Requirement: 24 ± 8 °C Sample Type: [ ] Insulation [x] Jacket Sample Preparation: [ ] Tubular [X] Die Cut [ ] Buffed Speed of Separation: 20 Inches Per Minute Actual Speed of Separation: 20 Inches Per Minute [ ] Planed Conditioning: [X] Unaged Specimen No. 1 2* 3* 4* width of die, mils. 250.0 - - - thickness of die, mils. 31.5 - - - - - - - Peak load, lbf 21.07 - - - Tensile strength, lbf/in2 2676.2 - - - Bench marks broke at, in. 3.82 - - - 282 - - - Results Results of * 2676.2 - 2 Area, in Elongation, percent Average tensile strength, lbf/in2 Average elongation, percent 282 All Specimens were broken within gauge mark. J.S. ULS-00062-ZJCZ-DataSheet-2001 Form Page 8 2014-05-21 Form Issued: Form Revised: Copyright 2012 UL LLC Requirement Min. 1500 Min. 100 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Printed Name Page 9 of 14 Date 2014-05-13~ 2014-05-21 Signature PHYSICAL PROPERTIES: (CONT’D) UL 62 and CSA C22.2 No. 49, Clauses 5.1.2 Sample Card No.: 1865376 Material: PVC Ins/Jkt: Ambient Temp.: Sample No.: W5.W6 Jkt. Color: Black Humidity: 23°C 55% RH Conditioning: [X] After 7 [ ] After Days In Air Oven at 136 °C Hrs / Days in IRM902 Oil at _____ °C Test Start Date/Time: 2014-05-13/17:00 Test End Date/Time: 2014-05-20/17:00 Actual Aging Temperature: 136°C Specimen No. 1 2 3* 4* 5* width of die, mils. 250.0 250.0 - - - thickness of die, mils. 31.5 31.5 - - - - - - - - 26.61 24.68 - - - 3378.7 3134.1 - - - 2.81 2.80 - - - 181 180 - - - Area, in2 Peak load, lbf Tensile strength, lbf/in 2 Bench marks broke at, in. Elongation, percent Results Results of * Requirement 3256.4 - -- Percent of original 121.7 - Min. 85 Average elongation, percent 180.5 - -- Percent of original 64.0 - Min. 45 2 Average tensile strength, lbf/in All Specimens were broken within gauge mark. ULS-00062-ZJCZ-DataSheet-2001 Form Page 9 J.S. 2014-05-21 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Printed Name 1865376 Material: PVC 10 of 14 Date 2014-05-22 Signature MECHANICAL STRENGTH Sample Card No.: Page UL 62 and CSA C22.2 No. 49, Clause 5.1.4 Jacket: Sample No.: W7 -- Color: Ambient Temp.: 22 °C [X] Dead Weight Method [ ] Tensile Testing Machine Method Black Humidity: 59 % RH Applied force, lb. 150 Actual force applied, lb. 150 Requirement: There shall be no breaking of grounding or circuit conductors. RESULTS Specimen # 1 Were there any broken conductors? ULS-00062-ZJCZ-DataSheet-2001 Form Page 10 [Yes] Form Issued: Form Revised: Copyright 2012 UL LLC [No] 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Page Tested by: Date Printed Name Signature VERTICAL FLAME TEST – VW-1 OR FV2 Sample Card No.: 1865376 Material: PVC Ambient Temp.: 2014-05-22 UL 62 and CSA C22.2 No. 49, Clause 5.1.5.4 Ins./Jkt.: 23 °C 11 of 14 Sample No.: W8-W10 Ins. Color: Black Humidity: 51 % RH Requirement: There shall be no ignition of cotton, burns shall not exceed 60 sec, and no more than 25% of the indicator flag shall be consumed. Specimen # 1 # 2 # 3 Duration after 1st application (sec) 1 1 1 Duration after 2nd application (sec) 1 0 1 Duration after 3rd application (sec) 0 0 0 Duration after 4th application (sec) 0 0 0 Duration after 5th application (sec) 0 0 0 Percent of indicator flag burned 0 0 0 [Yes] [No] [Yes] [No] [Yes] [No] Cotton ignition? ULS-00062-ZJCZ-DataSheet-2001 Form Page 11 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Printed Name 1865376 Material: PVC Ambient Temp.: 12 of 14 Date 2014-05-22 Signature VERTICAL FLAME TEST – VW-1 OR FV2 Sample Card No.: Page UL 62 and CSA C22.2 No. 49, Clause 5.1.5.4 Ins./Jkt.: 23 °C Sample No.: W11-W13 Jkt. Color: Black Humidity: 51 % RH Requirement: There shall be no ignition of cotton, burns shall not exceed 60 sec, and no more than 25% of the indicator flag shall be consumed. Specimen # 1 # 2 # 3 Duration after 1st application (sec) 0 0 0 Duration after 2nd application (sec) 0 0 0 Duration after 3rd application (sec) 0 0 0 Duration after 4th application (sec) 0 0 0 Duration after 5th application (sec) 0 0 0 Percent of indicator flag burned 0 0 0 [Yes] [No] [Yes] [No] [Yes] [No] Cotton ignition? ULS-00062-ZJCZ-DataSheet-2001 Form Page 12 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Page Tested by: Date Printed Name 1865376 Material: PVC Ambient Temp.: 2014-05-22 Signature VERTICAL FLAME TEST – FT1 OR FV1 Sample Card No.: 13 of 14 UL 62 and CSA C22.2 No. 49, Clause 5.1.5.1 Ins./Jkt.: 23 °C Sample No.: W14-W16 Jkt. Color: Black Humidity: 51 % RH Requirement: Burns shall not exceed 60 sec, and more than 25% of the indicator flag shall not be consumed. [ ] Note: Conduct Vertical Flame Test – FT1 OR FV1 only when Vertical Flame Test – VW-1 or FV2 fails. Specimen Duration of specimen flaming after 5th flame application (sec.) Dripping of flaming particles Percent of indicator flag burned ULS-00062-ZJCZ-DataSheet-2001 Form Page 13 # 1 # 2 # 3 0 0 0 Yes / No Yes / No Yes / No 0 0 0 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL. Project No. F140643 File E313867 Tested by: Page Date Printed Name Signature 14 of 14 2014-05-22 END OF DATASHEET PACKAGE.THIS PAGE INTENTIONALLY LEFT BLANK ULS-00062-ZJCZ-DataSheet-2001 Form Page 14 Form Issued: Form Revised: Copyright 2012 UL LLC 2004-02-20 2011-05-16 Only those products bearing the UL Mark should be considered as being covered by UL.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Extract Author : 33796 Create Date : 2014:05:27 14:35:42+08:00 Modify Date : 2016:09:21 14:59:36+08:00 Subject : XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : GPL Ghostscript 9.07 Keywords : Creator Tool : PDFCreator Version 1.7.1 Metadata Date : 2016:09:21 14:59:36+08:00 Document ID : uuid:a8ae6c4d-e7c4-11e3-0000-cd313475d560 Instance ID : uuid:c711ab42-d3bb-4182-a38c-dd469d8e2f99 Format : application/pdf Title : 100% F140643 Q SJT ZJCZ(105C,VW-1,FT1,18AWG) Creator : 33796 Description : Description (x-repair) : Page Count : 14EXIF Metadata provided by EXIF.tools