Traverse LED Spec Sheet
2017-07-19
: Pdf Traverse Led Spec Sheet Traverse_LED_spec_sheet spec products beacon
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
TRAVERSE SERIES Cat.# Job Type design . per formance . technology Approvals SURFACE/CEILING/GARAGE SPECIFICATIONS PRODUCT IMAGE(S) Intended Use: The Traverse luminaire is a wall surface mounted luminaire with a field replaceable LED light engine & optical bezel system. Internal components are totally enclosed in rain-tight and corrosion-resistant die cast aluminum housing. The TRV Luminaire is suitable for wet locations. Construction: • Traverse luminaire consists of a die cast aluminum two-piece housing. • Die cast main (thermal) housing provides direct heat exchange between the LED light engine and the cool outdoor air by drawing heat through integral heat channels and out to the sculptured and functional luminaire surface. • LED drivers are thermally isolated from the main housing, mechanically attached and heat sinked to the rear housing. • Main housing is designed with heat dissipat ing fins for LED thermal management without the use of metallic screens, cages, or fans. • Shape of the main housing is designed to prevent debris accumulation and as a bird nesting deterrent. The back and main housings are designed to hinge open for easy mounting and easy access. Electrical: • 100V through 277V, 50 Hz to 60 Hz (UNV). • Power factor is min 0.92 at full load. • All electrical components are rated at 50,000 hours at full load and 40°C ambient conditions per MIL-217F Notice 2. • Optional 0 to 10 volt dimming drivers are available upon request. • Component-to-component wiring within the luminaire may carry no more than 80% of rated load and is listed by UL for use at 600VAC at 50°C or higher. • Plug disconnects are listed by UL for use at 600 VAC, 15A or higher. 15A rating applies to primary (AC) side only. • Surge protection - 20KA www.beaconproducts.com/products/energeni • In addition, Traverse can be specified with SiteSync™ wireless control system for reduction in energy and maintenance cost while optimizing light quality 24/7. See ordering information or visit: www.hubbelllighting.com/sitesync/ for more details Installation: • Rear housing (back plate) is designed with various bolt patterns for direct wall mounting or mounting to a recessed 4” junction box. • Rear housing has three integral 3/4” NPT power feed locations (bottom and each side) for surface mounted conduit applications. • After mounting the rear housing to the wall or junction box, the main housing is designed to hang and hinge closed after connecting the male and female quick connectors. • Mounting design permits a simple retrofit to existing wall luminaires that utilize surface mount or recessed junction boxes. Finish: • IFS polyester powder-coat electro- statically applied and thermocured. • IFS finish consists of a five stage iron phosphate chemical pretreatment regimen with a polymer primer sealer, oven dry off, and top coated with a thermoset super TGIC polyester powder coat finish. • The finish meets the AAMA 605.2 perfor mance specification which includes passing a 3000 hour salt spray test for corrosion resistance and resists cracking or loss of adhesion per ASTM D522 and resists surface impacts of up to 160 inch-pounds. Shown with SiteSync™ DIMENSIONS 12 1/2” 7 1/4” LED/Optics: • Optical one piece cartridge system consisting of an LED engine, LED lamps, optics, gasket and stainless steel bezel. • Cartridge is held together with internal brass standoffs soldered to the board so that it can be field replaced as a one piece optical system. • A two-piece die cut silicone and polycarbon ate foam gasket ensures a weather-proof seal around each individual LED and allows the Traverse luminaire to be rated for high-pressure hose down applications. • Optical cartridge is secured to the extruded housing with fasteners and a heat pad to ensure thermal conductivity. • Optics are held in place without the use of adhesives and the complete assembly is gasketed for high pressure hose down cleaning. • Cartridge assembly is available in various lighting distributions using TIR designed acrylic optical lenses over each LED. Controls/Options: • Traverse is available with an optional passive infrared (PIR) motion sensor capable of detecting motion 360° around the luminaire. When no motion is detected for the specified time, the Motion Response system reduces the wattage down to a factory preset level, reducing light level accordingly. When motion is detected, the luminaire returns to full wattage and full light output. Please contact Beacon Products if project requirements vary from the standard configurations • Available with Energeni for optional set dimming with simple delay, or timed dimming based on time of night (see Energeni product page for more details Side View 14” Front View Listings: • The luminaire shall bear a CSA label and be marked suitable for wet locations (standard). • This product is approved by the Florida Fish and Wildlife Conservation Commission. Separate spec available at: http://www.beaconproducts.com/products/traverse Top View Warranty: Five year limited warranty for more information visit: www.hubbelllighting.com/resources/warranty CERTIFICATIONS/LISTINGS Bottom View *3000K and warmer CCTs only Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. design . per formance . technology © 2016 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA TRV-SPEC 11/16 ORDERING INFORMATION SERIES ORDERING EXAMPLE: TRV-D/60NB-136/5K/T5R/UNV/GENIXX/PEC/BBT LED COLOR11 ENGINE-WATTS TRV-D Traverse Down Light TRV-U1 Traverse Up Light (lens req.) 24NB-27 24NB-55 36NB-80 27 Watts - LED array 55 Watts - LED array OPTICS 3K 3000K 4K 4000K 5K 5000K T2 Type II T3 Type III T4 Type IV 80 Watts - LED array T5R Type V, rectan- 48NB-110 110 Watts - LED array 2X2 Narrow spot 60NB-136 136 Watts - LED array FINISH CONTROL OPTIONS BBT BMT WHT MBT BZT DBT GYS GENI-XX Energeni SWP7,8 SiteSync Wire6 SWPM7,8,9 gular flood 5X5 Medium flood less Pre-Commission SiteSync Wireless Pre-Commission w/ Occupancy Sensor basic black textured black matte textured white textured metallic bronze textured bronze textured dark bronze textured gray smooth DPS dark platinum smooth GNT green textured VOLTAGE MST metallic silver textured UNV 120-277V SENSOR OPTIONS 347 347V MTT metallic titanium textured OWI old world iron MOB3,5,7,9 Occupancy Sensor 480 480V (33% or 50% dimming) RAL _____________ ELECTRICAL OPTIONS PEC Photocell, button 2PF2,3, 10 Dual power feed Indoor use only Not available on 24NB-27 Not available @ 347V or 480V input 4 36NB-80 only, not available with SWP or SWPM control options 5 Not available on 48NB-110 or 60NB-136 6 When ordering Energeni, specify the routine setting code (example GENI-04). See Energeni brochure and instructions for setting table and options. Not available with sensor options. 7 Not available with other control or sensor options. PEC is available with MOB and OCS. 8 Specify group and zone. See SiteSync product page www.hubbelllighting.com/controls/sitesync for more details. 9 Specify time delay; dimming level and mounting height. 10 Not available with SWP or SWPM control options. 11 This product is approved by the Florida Fish and Wildlife Conservation Commission. Separate spec available at: http://cdn.beaconproducts.com/content/products/specs/specs_files/Traverse_LED_turtle_spec_sheet.pdf 1 BPC4 Cold weather battery 2 pack 3 Accessories and Services (Ordered Separately) Catalog Number Description SWUSB* SiteSync loaded on USB flash drive (Windows based only) SWTAB* SiteSync Windows Tablet SWBRG SiteSync Wireless Bridge Node + PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting control option, additional information will be required to complete the order. The SiteSync Commissioning Form or alternate schedule information must be completed. This form includes Project location, Group information, and Operating schedules. For more detailed information please visit www.hubbelllighting.com/products/sitesync/ or contact Hubbell Lighting tech support at (800) 345-4928. * When ordering with SiteSync, one of the following interface options must be chosen and ordered separately. Each option contains the SiteSync License, GUI and Bridge Node. + If needed, an additional Bridge Node can be ordered. SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens. Examples: TRV/24NB-55/5K/T3/UNV/SWP/DBT TRV/24NB-55/5K/T3/UNV/SWPM-20F/DBT SiteSync only SiteSync with Occupancy Sensor MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. 33% or 50% - _____ ?? / DBT 1 to 30 min. - __________ TRV/24NB-55/5K/T3/UNV/MOB - __________ High to Dim Delay Low Level Mounting Height (ft.) SiteSync Lighting Control is available from our most popular brands in a broad range of award-winning product families. Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. design . per formance . technology © 2015 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA TRV-SPEC 11/16 PHOTOMETRICS Type III TRV-60NB-136-5K-T3 Type II TRV-60NB-136-5K-T2 Type IV TRV-60NB-136-5K-T4 PERFORMANCE DATA # LED’S DRIVE CURRENT (MILLIAMPS) 5K (5000K nominal, 70 CRI) SYSTEM WATTS 24 350mA 27w 24 700mA 55w 36 700mA 80w 48 700mA 110w 60 700mA 136w DISTRIBUTION TYPE LUMENS T2 T3 T4 T5R 5X5 2X2 T2 T3 T4 T5R 5X5 2X2 T2 T3 T4 T5R 5X5 2X2 T2 T3 T4 T5R 5X5 2X2 T2 T3 T4 T5R 5X5 2X2 2833 2805 3086 3142 3031 3287 5666 5610 6171 6283 6063 6573 8505 8415 9256 9425 9094 9860 11332 11220 12342 12567 12126 13147 14165 14025 15427 15708 15157 16434 4K (4000K nominal, 70 CRI) 3K (3000K nominal, 80 CRI) LPW1 B U G LUMENS LPW1 B U G LUMENS 105 104 114 116 112 122 102 101 111 113 110 118 101 100 110 112 109 118 102 101 111 113 109 118 103 102 113 115 111 120 1 1 1 2 2 3 2 1 1 3 3 4 2 2 1 3 4 4 3 2 2 4 4 5 3 3 2 4 4 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 2 1 1 2 2 2 3 1 1 3 2 3 3 1 1 3 3 3 4 1 1 3 3 3 4 1 2 2805 2777 3055 3111 3001 3254 5610 5554 6110 6221 6002 6508 8415 8331 9164 9331 9003 9762 11220 11108 12219 12441 12004 13016 14025 13885 15274 15259 15006 16269 104 103 113 115 111 121 101 100 109 111 109 117 100 99 109 111 108 116 101 100 110 112 108 117 102 101 111 111 110 119 1 1 1 2 2 3 2 1 1 3 3 4 2 2 1 3 4 4 3 2 2 4 4 5 3 3 2 4 4 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 2 1 1 2 2 2 3 1 1 3 2 3 3 1 1 3 3 3 4 1 1 3 3 3 4 1 2 2408 2392 2623 2670 2577 2794 4816 4784 5245 5341 5153 5587 7224 7175 7868 8011 7730 8381 9633 9567 10491 10682 10307 11175 12041 11959 13114 13352 12884 13968 LPW1 B U 89 89 97 99 95 103 86 86 94 96 94 100 87 86 94 96 93 100 87 86 95 96 93 101 88 87 96 97 94 102 1 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown. Actual performance may differ as a result of end-user environment and application. Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. design . per formance . technology © 2015 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA TRV-SPEC 11/16 1 1 1 2 2 3 1 1 1 3 3 4 2 2 1 3 3 4 2 2 2 3 4 5 3 3 2 4 4 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G 1 1 1 2 1 1 2 2 2 3 1 1 2 2 3 3 1 1 3 3 3 3 1 1 3 3 3 4 1 1 PROJECTED LUMEN MAINTENANCE AMBIENT TEMP. 25°C / 77°F TM-21-11 Calculated L70 60,000 100,000 (HOURS) 0.95 0.93 >560,000 1 0 25,000 1.00 0.97 50,000 0.96 1 Projected per IESNA TM-21-11 Data references the extrapolated performance projections for the base model in a 40°C ambient, based on 10,000 hours of LED testing per IESNA LM-80-08. ELECTRICAL DATA # OF LEDS NUMBER OF DRIVERS DRIVE CURRENT (mA) 24 1 (350mA) 24 2 (700mA) 36 1 (700mA) 48 1 (700mA) 60 1 (700mA) INPUT VOLTAGE (V) 120 277 120 277 120 277 120 277 120 277 OPER. CURRENT (Amps) 0.23 0.10 0.46 0.20 0.68 0.30 0.92 0.40 1.13 0.49 SYSTEM POWER (Watts) 27.0 55.0 80.0 110.0 AMBIENT TEMPERATURE 0°C 32°F 10°C 50°F 20°C 68°F 25°C 77°F 86°F 30°C 40°C 104°F 50°C 122°F LUMEN MULTIPLIER 1.02 1.01 1.00 1.00 1.00 0.99 0.98 Use these factors to determine relative lumen output for average ambient temperatures from 0-50°C (32-122°F). 136.0 Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. design . per formance . technology © 2015 BEACON PRODUCTS, All Rights Reserved • For more information visit our website: www.beaconproducts.com • Printed in USA July 18, 2017 2:42 PM