Traverse LED Spec Sheet

2017-07-19

: Pdf Traverse Led Spec Sheet Traverse_LED_spec_sheet spec products beacon

Open the PDF directly: View PDF PDF.
Page Count: 4

CERTIFICATIONS/LISTINGS
DIMENSIONS
PRODUCT IMAGE(S)SPECIFICATIONS
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2016 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA TRV-SPEC 11/16
Cat.#
Approvals
Job Type design . performance . technology
design . performance . technology
TRAVERSE
SERIES
SURFACE/CEILING/GARAGE
Intended Use:
The Traverse luminaire is a wall surface
mounted luminaire with a eld replaceable LED
light engine & optical bezel system. Internal
components are totally enclosed in rain-tight
and corrosion-resistant die cast aluminum
housing. The TRV Luminaire is suitable for wet
locations.
Construction:
• Traverse luminaire consists of a die cast
aluminum two-piece housing.
• Die cast main (thermal) housing provides
direct heat exchange between the LED light
engine and the cool outdoor air by drawing
heat through integral heat channels and out
to the sculptured and functional luminaire
surface.
• LED drivers are thermally isolated from the
main housing, mechanically attached and
heat sinked to the rear housing.
• Main housing is designed with heat dissipat
ing ns for LED thermal management without
the use of metallic screens, cages, or fans.
• Shape of the main housing is designed to
prevent debris accumulation and as a bird
nesting deterrent. The back and
main housings are designed to hinge open
for easy mounting and easy access.
LED/Optics:
• Optical one piece cartridge system
consisting of an LED engine, LED lamps,
optics, gasket and stainless steel bezel.
• Cartridge is held together with internal brass
standos soldered to the board so that it
can be eld replaced as a one piece optical
system.
• A two-piece die cut silicone and polycarbon
ate foam gasket ensures a weather-proof
seal around each individual LED and allows
the Traverse luminaire to be rated for
high-pressure hose down applications.
• Optical cartridge is secured to the extruded
housing with fasteners and a heat pad to
ensure thermal conductivity.
• Optics are held in place without the use of
adhesives and the complete assembly is
gasketed for high pressure hose
down cleaning.
• Cartridge assembly is available in various
lighting distributions using TIR designed
acrylic optical lenses over each LED.
Electrical:
• 100V through 277V, 50 Hz to 60 Hz (UNV).
• Power factor is min 0.92 at full load.
• All electrical components are rated at 50,000
hours at full load and 40°C ambient
conditions per MIL-217F Notice 2.
• Optional 0 to 10 volt dimming drivers are
available upon request.
• Component-to-component wiring within the
luminaire may carry no more than 80% of
rated load and is listed by UL for use at
600VAC at 50°C or higher.
• Plug disconnects are listed by UL for use at
600 VAC, 15A or higher. 15A rating applies
to primary (AC) side only.
Surge protection - 20KA
Controls/Options:
• Traverse is available with an optional passive
infrared (PIR) motion sensor capable of
detecting motion 360° around the
luminaire. When no motion is detected
for the specied time, the Motion Response
system reduces the wattage down
to a factory preset level, reducing light level
accordingly. When motion is detected,
the luminaire returns to full wattage and
full light output. Please contact Beacon
Products if project requirements vary
from the standard congurations
Available with Energeni for optional set
dimming with simple delay, or timed dimming
based on time of night
(see Energeni product page for more details
www.beaconproducts.com/products/energeni
In addition, Traverse can be specied with
SiteSync™ wireless control system
for reduction in energy and maintenance cost
while optimizing light quality 24/7. See
ordering information or visit:
www.hubbelllighting.com/sitesync/
for more details
Installation:
• Rear housing (back plate) is designed with
various bolt patterns for direct wall mounting
or mounting to a recessed 4” junction box.
• Rear housing has three integral 3/4” NPT
power feed locations (bottom and
each side) for surface mounted conduit
applications.
• After mounting the rear housing to the wall or
junction box, the main housing is designed to
hang and hinge closed after connecting the
male and female quick connectors.
• Mounting design permits a simple retrot
to existing wall luminaires that utilize surface
mount or recessed junction boxes.
Finish:
• IFS polyester powder-coat electro-
statically applied and thermocured.
• IFS nish consists of a ve stage
iron phosphate chemical pretreatment
regimen with a polymer primer sealer,
oven dry o, and top coated with
a thermoset super TGIC polyester
powder coat nish.
• The nish meets the AAMA 605.2 perfor
mance specication which includes
passing a 3000 hour salt spray test for
corrosion resistance and resists cracking or
loss of adhesion per ASTM D522
and resists surface impacts of up to 160
inch-pounds.
Listings:
• The luminaire shall bear a CSA label and be
marked suitable for wet locations (standard).
This product is approved by the Florida Fish
and Wildlife Conservation Commission.
Separate spec available at:
http://www.beaconproducts.com/products/traverse
Warranty:
Five year limited warranty for more information visit:
www.hubbelllighting.com/resources/warranty
Bottom View
Top View
Front View
Side View
14”
12 1/2”
7 1/4”
*3000K and warmer CCTs only
Shown with SiteSync™
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA TRV-SPEC 11/16
design . performance . technology
ORDERING INFORMATION
SERIES
TRV-D Traverse Down
Light
TRV-U1Traverse Up
Light (lens req.)
OPTICS
T2 Type II
T3 Type III
T4 Type IV
T5R Type V, rectan-
gular
2X2 Narrow spot
flood
5X5 Medium flood
VOLTAGE
UNV 120-277V
347 347V
480 480V
FINISH
BBT basic black textured
BMT black matte textured
WHT white textured
MBT metallic bronze textured
BZT bronze textured
DBT dark bronze textured
GYS gray smooth
DPS dark platinum smooth
GNT green textured
MST metallic silver textured
MTT metallic titanium textured
OWI old world iron
RAL _____________
CONTROL OPTIONS
GENI-XX6Energeni
SWP7,8 SiteSync Wire-
less Pre-Com-
mission
SWPM7,8,9 SiteSync Wire-
less Pre-Com-
mission w/
Occupancy
Sensor
LED COLOR11
3K 3000K
4K 4000K
5K 5000K
ENGINE-WATTS
24NB-27 27 Watts - LED
array
24NB-55 55 Watts - LED
array
36NB-80 80 Watts - LED
array
48NB-110 110 Watts - LED
array
60NB-136 136 Watts - LED
array
ELECTRICAL OPTIONS
PEC Photocell, button
2PF2,3, 10 Dual power feed
BPC4Cold weather battery
pack
1 Indoor use only
2 Not available on 24NB-27
3 Not available @ 347V or 480V input
4 36NB-80 only, not available with SWP or SWPM control options
5 Not available on 48NB-110 or 60NB-136
6 When ordering Energeni, specify the routine setting code (example GENI-04). See Energeni brochure and
instructions for setting table and options. Not available with sensor options.
7 Not available with other control or sensor options. PEC is available with MOB and OCS.
8 Specify group and zone. See SiteSync product page www.hubbelllighting.com/controls/sitesync for more details.
9 Specify time delay; dimming level and mounting height.
10 Not available with SWP or SWPM control options.
11 This product is approved by the Florida Fish and Wildlife Conservation Commission. Separate spec available at:
http://cdn.beaconproducts.com/content/products/specs/specs_files/Traverse_LED_turtle_spec_sheet.pdf
ORDERING EXAMPLE: TRV-D/60NB-136/5K/T5R/UNV/GENIXX/PEC/BBT
SENSOR OPTIONS
MOB3,5,7,9 Occupancy Sensor
(33% or 50%
dimming)
SiteSync Lighting Control is available from
our most popular brands in a broad range of
award-winning product families.
PRECOMMISSIONED SITESYNC ORDERING INFORMATION: When ordering a fixture with the SiteSync lighting
control option, additional information will be required to complete the order. The SiteSync Commissioning Form
or alternate schedule information must be completed. This form includes Project location, Group information, and
Operating schedules. For more detailed information please visit www.hubbelllighting.com/products/sitesync/ or
contact Hubbell Lighting tech support at (800) 345-4928.
SiteSync fixtures with occupancy sensor (SWPM) require the mounting height of the fixture for selection of the lens.
Examples: TRV/24NB-55/5K/T3/UNV/SWP/DBT SiteSync only
TRV/24NB-55/5K/T3/UNV/SWPM-20F/DBT SiteSync with Occupancy Sensor
MOB ORDERING INFORMATION: When ordering a fixture with a dimming occupancy sensor option (MOB), please
specify the appropriate information. These settings are specified in the ordering as shown in the example below.
TRV/24NB-55/5K/T3/UNV/MOB - __________ - __________ - _____ / DBT
1 to 30 min.33% or 50% ??
High to Dim Delay Low Level Mounting Height (ft.)
Catalog Number Description
SWUSB* SiteSync loaded on USB flash drive (Windows based only)
SWTAB* SiteSync Windows Tablet
SWBRG+SiteSync Wireless Bridge Node
* When ordering with SiteSync, one of the following interface options must be chosen and ordered
separately. Each option contains the SiteSync License, GUI and Bridge Node.
+ If needed, an additional Bridge Node can be ordered.
Accessories and Services (Ordered Separately)
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA TRV-SPEC 11/16
design . performance . technology
5K
(5000K nominal, 70 CRI)
4K
(4000K nominal, 70 CRI)
3K
(3000K nominal, 80 CRI)
# LED’S
DRIVE
CURRENT
(MILLIAMPS)
SYSTEM
WATTS
DISTRIBUTION
LUMENS
LPW
1
B
U
G
LUMENS
LPW
1
B
U
G
LUMENS
LPW
1
B
U
G
24 350mA 27w
T2 2833 105 1 0 1 2805 104 1 0 1 2408 89 1 0 1
T3 2805 104 1 0 1 2777 103 1 0 1 2392 89 1 0 1
3086
114
1
0
1
3055
113
1
0
1
2623
97
1
0
1
3142
116
2
0
2
3111
115
2
0
2
2670
99
2
0
2
5X5 3031 112 2 0 1 3001 111 2 0 1 2577 95 2 0 1
2X2 3287 122 3 0 1 3254 121 3 0 1 2794 103 3 0 1
24 700mA 55w
T2 5666 102 2 0 2 5610 101 2 0 2 4816 86 1 0 2
5610
101
1
0
2
5554
100
1
0
2
4784
86
1
0
2
6171
111
1
0
2
6110
109
1
0
2
5245
94
1
0
2
T5R 6283 113 3 0 3 6221 111 3 0 3 5341 96 3 0 3
5X5 6063 110 3 0 1 6002 109 3 0 1 5153 94 3 0 1
2X2 6573 118 4 0 1 6508 117 4 0 1 5587 100 4 0 1
36 700mA 80w
8505
101
2
0
3
8415
100
2
0
3
7224
87
2
0
2
8415
100
2
0
2
8331
99
2
0
2
7175
86
2
0
2
T4 9256 110 1 0 3 9164 109 1 0 3 7868 94 1 0 3
T5R 9425 112 3 0 3 9331 111 3 0 3 8011 96 3 0 3
5X5 9094 109 4 0 1 9003 108 4 0 1 7730 93 3 0 1
9860
118
4
0
1
9762
116
4
0
1
8381
100
4
0
1
48 700mA 110w
11332
102
3
0
3
11220
101
3
0
3
9633
87
2
0
3
T3 11220 101 2 0 3 11108 100 2 0 3 9567 86 2 0 3
T4 12342 111 2 0 3 12219 110 2 0 3 10491 95 2 0 3
T5R 12567 113 4 0 4 12441 112 4 0 4 10682 96 3 0 3
12126
109
4
0
1
12004
108
4
0
1
10307
93
4
0
1
13147
118
5
0
1
13016
117
5
0
1
11175
101
5
0
1
60 700mA 136w
T2 14165 103 3 0 3 14025 102 3 0 3 12041 88 3 0 3
T3 14025 102 3 0 3 13885 101 3 0 3 11959 87 3 0 3
T4 15427 113 2 0 3 15274 111 2 0 3 13114 96 2 0 3
15708
115
4
0
4
15259
111
4
0
4
13352
97
4
0
4
15157
111
4
0
1
15006
110
4
0
1
12884
94
4
0
1
2X2 16434 120 5 0 2 16269 119 5 0 2 13968 102 5 0 1
1Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be
representative of the configurations shown. Actual performance may differ as a result of end-user environment and application.
PERFORMANCE DATA
Type II
TRV-60NB-136-5K-T2
Type III
TRV-60NB-136-5K-T3
Type IV
TRV-60NB-136-5K-T4
PHOTOMETRICS
Beacon Products • 2041 58th Avenue Circle East Bradenton, FL 34203 • Phone: 800-345-4928
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2015 BEACON PRODUCTS, All Rights ReservedFor more information visit our website: www.beaconproducts.com • Printed in USA July 18, 2017 2:42 PM
design . performance . technology
PROJECTED LUMEN MAINTENANCE
AMBIENT
TEMP.
0
25,000
50,000
1
TM-21-11
60,000
100,000
Calculated L70
(HOURS)
25°C / 77°F 1.00 0.97 0.96 0.95 0.93 >560,000
1 Projected per IESNA TM-21-11
Data references the extrapolated performance projections for the base model in a 40°C
ambient, based on 10,000 hours of LED testing per IESNA LM-80-08.
AMBIENT TEMPERATURE
LUMEN MULTIPLIER
0°C
32°F
1.02
10°C
50°F
1.01
20°C
68°F
1.00
25°C
77°F
1.00
30°C
86°F
1.00
40°C
104°F
0.99
50°C
122°F
0.98
Use these factors to determine relative lumen output for average ambient
temperatures from 0-50°C (32-122°F).
# OF LEDS
NUMBER
OF
DRIVERS
DRIVE
CURRENT
(mA)
INPUT VOLTAGE
(V)
OPER. CURRENT
(Amps)
SYSTEM POWER
(Watts)
24 1(350mA)
120
0.23
27.0
277
0.10
24 2(700mA)
120
0.46
55.0
277
0.20
36 1(700mA)
120
0.68
80.0
277
0.30
48 1(700mA)
120
0.92
110.0
277
0.40
60 1(700mA)
120
1.13
136.0
277
0.49
ELECTRICAL DATA

Navigation menu