Tre22
2017-07-29
: Pdf Tre22 tre22 spec products columbia
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
TRE22 2' × 2' Transition® Enclosed High Efficiency Architectural Lens PROJECT INFORMATION FEATURES • • • • • • • • • • Enclosed high transmission extruded acrylic lens features linear prisms custom frost for superior lamp diffusion Appropriate for schools, medical facilities, dining areas, locker rooms, and public spaces Enclosed lens protects against intrusion of contaminants Optional Antimicrobial® paint (AM option) resists bacterial growth on exposed painted surfaces High performance matte white paint standard T8, T5, T5HO, and Twin Tube lamps available; for LED see LTRE series Lens gasket optional Wet label listing optional Controls compatible for code compliance and energy savings Completely recessed; provides a smooth ceiling aesthetic with uniform illumination Project Name Type Catalog No. Date CONSTRUCTION Luminaire housing and end caps are die formed code gauge cold rolled steel. Reflector is stiffened with linear forms, profiled to a precision curve. High transmission extruded acrylic enclosed lens features linear prisms custom frost for superior lamp diffusion. All reflective surfaces are finished after fabrication with unique formula high reflectivity matte white paint for soft, uniform indirect illumination. Optional Antimicrobial® paint (AM option) resists bacterial growth on exposed painted surfaces. SHIELDING Enclosed thermoplastic light seals snap into the housing at both ends of the lens to prevent light leaks. Lens hinges down for easy access to center wireway. Optional gasketing available to surround the lamp cavity. FINISH All reflective surfaces are finished after fabrication with unique formula high reflectivity matte white paint for soft, uniform indirect illumination. Antimicrobial® high performance matte white paint available as option, specify -AM as option. INSTALLATION An access plate is furnished with each luminaire for fast wiring access from the plenum without the necessity to open the fixture or wireway. BALLASTS Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant. ELECTRICAL Standard class “P”, thermally protected, auto-resetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/ CEC-compliant ballast disconnect is standard. CEILING COMPATIBILITY NEC-compliant T-Bar clips supplied with all grid trim fixtures. See ceiling details on reverse. For 9⁄16" wide Slot Grid or Screw Slot ceilings (SG) order G ceiling type; fixture in SG will be regressed 3/8” from the face of the ceiling tee. For hard ceilings order G ceiling type and FK flange accessory. Cable Mount (CM) provides suspension below the ceiling plane. CERTIFICATION All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location listing is standard. Wet location listing available on most configurations. Emergencyequipped fixtures labeled UL 924 and Dry Location unless specified. For IC rated configurations, contact your local Hubbell Lighting representative. UL Sanitation Approved. ORDERING INFORMATION 22 TRE EXAMPLE TRE22-224G-RFA-EPU – MODEL – NO. OF LAMPS TRE Transition® Enclosed High Efficiency Architectural Lens 1 One 2 Two 3 Three SIZE 22 2' × 2' ACCESSORIES (ORDER SEPARATELY) FK22 2' × 2' Single Flange Kit (Shipped separately) CM48Y2SC3F-KIT 48" Cable Mount Kit for 2' wide CM Trim fixtures, 3 Wire 2 Page 1/3 Rev. 07/26/17 – CEILING TYPE SHIELDING G Grid Lay-in1 SM Surface Mount CM Cable Mount2 RFA Ribbed Frosted Acrylic LAMP TYPE 17 14 24 40TT 2', T8: 17 Watt 2', T5: 14 Watt 2', T5HO: 24 Watt Twin Tube Compact, 2G11 Base: 40 Watt 50TT Twin Tube Compact, 2G11 Base, 50 Watt For drywall order FK22 accessories separately. Order hanger accessories separately. 3 Can be converted to fixed output by tying hot leads together. 4 Optional Antimicrobial® paint (AM option) resists bacterial growth on exposed painted surfaces. 5 In-Fixture Module Antenna adds 2" to overall fixture height at power feed location. 6 Not available with Surface Mount ceiling types. 7 Not available with Cable Mount ceiling types. 1 RFA – OPTIONS VOLTAGE U 120V-277V C388 C488 C588 GLR EL EL5 E Electronic T8, Instant Start ED Electronic Dimming T8 and T5* EP Electronic T5, T5HO, or T8, Programmed Start ESD Electronic Step Dimming for 2-Lamp T8 or T5 (14W) only3 E104 Electronic T8, 1.04 Ballast Factor, Instant Start ESD104 Electronic T8, 1.04 Ballast Factor, Step Dimming, Programmed Start3 ETT Electronic Twin Tube, Instant Start (specify voltage) EPTT Electronic Twin Tube, Programmed Start * Specify vendor and series. NYC NYCU AM G1 WL EOR BALLAST INT CP 3-Wire Flex 4-Wire Flex 5-Wire Flex Fast Blow Fuse Emergency Battery Pack6,7 Emergency Battery Pack, T5 or T5HO6,7 NYC Compliant NYC Compliant, Union Label Antimicrobial® Paint4 Lens Gasketing Wet Label6,7 End of Row (SM and CM only. Provides end wiring access for continuous row mounting.) Intermediate (SM and CM only. Provides ends with wiring access for continuous row mounting.) Chicago Plenum RECESSED ARCHITECTURAL / TRE22 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com TRE22 2' × 2' Transition® Enclosed High Efficiency Architectural Lens PHOTOMETRIC DATA ZONAL LUMEN SUMMARY Zone LUMINAIRE DATA TRE22-224G-RFA-EPU TRA Transition, Recessed Architectural 2 x 2 2-lamp with frosted linear prismed lens ICN-2S24 1.00 F24T5 1750 51 Recessed 0º = 90 90º = 90 0º = 1.22 90º = 1.38 Length: 1.92 Width: 1.92 Height: 0.00 Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet RCR 3 74 80 50 30 85 82 10 78 70 87 70 50 30 83 80 10 77 717 20.5 24.7 ENERGY DATA 1188 33.9 40.9 Total Luminaire Efficiency 83.0% 0-60 2177 62.2 74.9 0-90 2906 83.0 100.0 0-180 2906 83.0 100.0 Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 57 Non-Compliant $4.21 based on 3000 hrs. and $0.08 per KWH INDOOR CANDELA PLOT AVG. LUMINANCE (Candela/Sq. M.) 90 75 COEFFICIENTS OF UTILIZATION (%) RC RW 70 1 90 2 81 0-30 0-40 450 50 80 50 30 77 10 74 0 0 68 74 68 63 79 72 67 62 69 64 60 56 64 57 51 71 63 56 51 60 55 50 46 4 67 57 49 43 65 56 48 43 53 47 42 39 5 62 50 43 37 60 49 42 37 48 41 36 34 6 57 45 38 32 55 44 37 32 43 36 32 29 7 52 41 33 28 51 40 33 28 39 32 28 26 8 49 37 30 25 47 37 30 25 36 29 25 23 9 46 34 27 22 44 34 27 22 33 26 22 20 10 43 31 25 20 42 31 25 20 30 24 20 18 60 Average Luminance Angle Luminaire Test 6946 Test Date 4/25/2013 Lumens % Lamp % Fixt. 0 30 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90.0 2648 2508 2394 2321 2244 2169 2067 1976 1861 1737 1597 1441 2648 2559 2489 2436 2385 2332 2266 2197 2126 2031 1900 1675 2648 2680 2702 2709 2721 2744 2768 2798 2817 2741 2573 2178 2648 2785 2904 2977 3066 3187 3323 3434 3458 3441 3077 2513 2648 2825 2977 3072 3193 3355 3545 3641 3705 3689 3245 2680 900 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance Page 2/3 Rev. 07/26/17 RECESSED ARCHITECTURAL / TRE22 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com TRE22 2' × 2' Transition® Enclosed High Efficiency Architectural Lens DIMENSIONAL DATA — GRID CEILING COMPATIBILITY Ceiling Type G placed in flat T-Bar Grid Ceiling 2315⁄16" 2311⁄16" 0.875" K.O. 43/4" 24" 47⁄8" 24" Recessed Section (G) End Type G Ceiling Mounting 24" For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum heights of 11/2" allowed. Ceiling Type G placed in Slot Grid or Screw Slot Ceiling Back of Housing, Grid 2311⁄16" 23 15/16" 0.875" K.O. 47⁄8" 24" 1/2" K.O. (2X) 2315⁄16" End Type SG Ceiling Mounting 24" For 9/16" slot grid type ceilings. Luminaire will be regressed 3/8" horizontal surface of the tee. Optional 1 5/8" 3 1/16" 11 15/16" FK Flange Kit 1 5/8" For hard ceiling applications, fixtures must be ordered with a flange kit that wires directly into the concealed ceiling opening for a clean finished appearance. For row configurations contact your local Columbia Representative. Flange kit cut out dimension for single FK22: 24 3⁄8" x 24 3⁄8" DIMENSIONAL DATA — SURFACE MOUNT End View Surface Section (SM) 53/16" 53/16" 247⁄8" 247⁄8" Back of Housing, Surface Mount (SM) and Cable Mount (CM) 247⁄8" 41/2" x 5" Mounting Collar (SM Only)* Surface Mount (SM) Option: (4) 3⁄8" DIA KOs (A) Surface Mount: Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 3⁄8", provided in center channel as indicated at left, marked "A". 23/4" 11/2" Thru Hole 247/8" Cable Mount (CM) Option: (4) 1/4" Thru Holes (B) 4" 23/4" Ground Screw 145/16" * Cable Mount: Order CM ceiling type. Use CM48Y2SC3F-KIT 48" Cable Mount Kit for 2' wide CM ceiling type fixtures. Mounting holes are provided in diagonal straps shown at left, marked "B". 41⁄2" For Cable Mount a 2" x 3" access plate with (4) 7⁄8" KOs provided in place of Mounting Collar shown. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 3/3 Rev. 07/26/17 RECESSED ARCHITECTURAL / TRE22 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com