RECESSED ARCHITECTURAL / TRE22
EXAMPLE TRE22224GRFAEPU
22
ORDERING INFORMATION
CONSTRUCTION
Luminaire housing and end caps are die formed code gauge cold
rolled steel. Reector is stiened with linear forms, proled to a
precision curve. High transmission extruded acrylic enclosed lens
features linear prisms custom frost for superior lamp diusion.
All reective surfaces are nished after fabrication with unique
formula high reectivity matte white paint for soft, uniform
indirect illumination. Optional Antimicrobial® paint (AM option)
resists bacterial growth on exposed painted surfaces.
SHIELDING
Enclosed thermoplastic light seals snap into the housing at both
ends of the lens to prevent light leaks. Lens hinges down for
easy access to center wireway. Optional gasketing available to
surround the lamp cavity.
FINISH
All reective surfaces are nished after fabrication with unique
formula high reectivity matte white paint for soft, uniform
indirect illumination. Antimicrobial® high performance matte
white paint available as option, specify -AM as option.
INSTALLATION
An access plate is furnished with each luminaire for fast
wiring access from the plenum without the necessity to
open the xture or wireway.
BALLASTS
Energy ecient, thermally protected, automatic resetting, Class P,
high power factor, sound rated A, unless otherwise specied. CEE
NEMA Premium compliant.
ELECTRICAL
Standard class “P”, thermally protected, auto-resetting HPF
ballast, sound rated A. CEE NEMA Premium compliant. All ballast
leads extend a minimum of 6" through access location. NEC/
CEC-compliant ballast disconnect is standard.
CEILING COMPATIBILITY
NEC-compliant T-Bar clips supplied with all grid trim xtures. See
ceiling details on reverse. For 9⁄16" wide Slot Grid or Screw Slot
ceilings (SG) order G ceiling type; xture in SG will be regressed
3/8” from the face of the ceiling tee. For hard ceilings order G
ceiling type and FK ange accessory. Cable Mount (CM) provides
suspension below the ceiling plane.
CERTIFICATION
All luminaires are built to UL 1598 standards and bear appropriate
UL and cUL or CSA labels. Damp location listing is standard. Wet
location listing available on most congurations. Emergency-
equipped xtures labeled UL 924 and Dry Location unless
specied. For IC rated congurations, contact your local Hubbell
Lighting representative. UL Sanitation Approved.
FEATURES
• Enclosed high transmission extruded acrylic lens features linear prisms
custom frost for superior lamp diusion
• Appropriate for schools, medical facilities, dining areas, locker rooms, and
public spaces
• Enclosed lens protects against intrusion of contaminants
• Optional Antimicrobial® paint (AM option) resists bacterial growth on
exposed painted surfaces
• High performance matte white paint standard
• T8, T5, T5HO, and Twin Tube lamps available; for LED see LTRE series
• Lens gasket optional
• Wet label listing optional
• Controls compatible for code compliance and energy savings
• Completely recessed; provides a smooth ceiling aesthetic with
uniform illumination
SIZE
22 2' × 2'
CEILING TYPE
GGrid Lay-in1
SM Surface Mount
CM Cable Mount2
OPTIONS
C388 3-Wire Flex
C488 4-Wire Flex
C588 5-Wire Flex
GLR Fast Blow Fuse
EL Emergency Battery Pack6,7
EL5 Emergency Battery Pack,
T5 or T5HO6,7
NYC NYC Compliant
NYCU NYC Compliant, Union Label
AM Antimicrobial® Paint4
G1 Lens Gasketing
WL Wet Label6,7
EOR End of Row (SM and CM only.
Provides end wiring access for
continuous row mounting.)
INT Intermediate (SM and CM only.
Provides ends with wiring
access for continuous row
mounting.)
CP Chicago Plenum
ACCESSORIES
ORDER SEPARATELY
FK22 2' × 2' Single Flange Kit
(Shipped separately)
CM48Y2SC3F-KIT 48" Cable Mount Kit for 2'
wide CM Trim fixtures, 3 Wire
VOLTAGE
U120V-277V
– –
SHIELDING
RFA Ribbed Frosted
Acrylic
– –
RFA
MODEL
TRE Transition®
Enclosed High
Efficiency
Architectural
Lens
TRE
NO. OF LAMPS
1One
2Two
3Three
LAMP TYPE
17 2', T8: 17 Watt
14 2', T5: 14 Watt
24 2', T5HO: 24 Watt
40TT Twin Tube
Compact, 2G11
Base: 40 Watt
50TT Twin Tube
Compact, 2G11
Base, 50 Watt
BALLAST
EElectronic T8, Instant Start
ED Electronic Dimming T8 and T5*
EP Electronic T5, T5HO, or T8,
Programmed Start
ESD Electronic Step Dimming for
2-Lamp T8 or T5 (14W) only3
E104 Electronic T8, 1.04 Ballast Factor,
Instant Start
ESD104 Electronic T8, 1.04 Ballast Factor,
Step Dimming, Programmed
Start3
ETT Electronic Twin Tube, Instant
Start (specify voltage)
EPTT Electronic Twin Tube,
Programmed Start
*Specify vendor and series.
1 For drywall order FK22 accessories separately.
2 Order hanger accessories separately.
3 Can be converted to fixed output by tying hot leads together.
4 Optional Antimicrobial® paint (AM option) resists bacterial growth on exposed painted surfaces.
5 In-Fixture Module Antenna adds 2" to overall fixture height at power feed location.
6 Not available with Surface Mount ceiling types.
7 Not available with Cable Mount ceiling types.
Page 1/3 Rev. 07/26/17
TRE22
2' × 2' Transition® Enclosed High Efficiency Architectural Lens
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Catalog No.
Project Name Type
Date
PROJECT INFORMATION
RECESSED ARCHITECTURAL / TRE22
ZONAL LUMEN SUMMARY
Zone Lumens % Lamp % Fixt.
0-30 717 20.5 24.7
0-40 118 8 33.9 40.9
0-60 2177 62.2 74.9
0-90 2906 83.0 100.0
0-180 2906 83.0 100.0
PHOTOMETRIC DATA
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
190 85 82 78 87 83 80 77 80 77 74 68
281 74 68 63 79 72 67 62 69 64 60 56
374 64 57 51 71 63 56 51 60 55 50 46
467 57 49 43 65 56 48 43 53 47 42 39
562 50 43 37 60 49 42 37 48 41 36 34
657 45 38 32 55 44 37 32 43 36 32 29
752 41 33 28 51 40 33 28 39 32 28 26
849 37 30 25 47 37 30 25 36 29 25 23
946 34 27 22 44 34 27 22 33 26 22 20
10 43 31 25 20 42 31 25 20 30 24 20 18
COEFFICIENTS OF UTILIZATION (%)
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
INDOOR CANDELA PLOT
ENERGY DATA
Total Luminaire Eciency 83.0%
Luminaire Ecacy Rating (LER) 57
IESNA RP-1-1993 Compliance Non-Compliant
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$4.21 based on
3000 hrs. and
$0.08 per KWH
LUMINAIRE DATA
AVG. LUMINANCE
Candela/Sq. M.
Test 6946 Test Date 4/25/2013
0.0 22.5 45.0 67.5 90.0
Average Luminance Angle
02648 2648 2648 2648 2648
30 2508 2559 2680 2785 2825
40 2394 2489 2702 2904 2977
45 2321 2436 2709 2977 3072
50 2244 2385 2721 3066 3193
55 2169 2332 2744 3187 3355
60 2067 2266 2768 3323 3545
65 1976 2197 2798 3434 36 41
70 1861 2126 2817 3458 3705
75 1737 2031 2741 34 41 3689
80 1597 1900 2573 3077 3245
85 1441 1675 2178 2513 2680
Luminaire TRE22-224G-RFA-EPU
TRA Transition,
Recessed Architectural
2 x 2 2-lamp with frosted linear
prismed lens
Ballast ICN-2S24
Ballast Factor 1.00
Lamp F24T5
Lumens per Lamp 1750
Watts 51
Mounting Recessed
Shielding Angle 0º = 90 90º = 90
Spacing Criterion 0º = 1.22 90º = 1.38
Luminous Opening
in Feet
Length: 1.92
Width: 1.92
Height: 0.00
Horiz 0-180
450
900
0
15 30 45
90
75
60
0.0 45.0 90.0
Page 2/3 Rev. 07/26/17
TRE22
2' × 2' Transition® Enclosed High Efficiency Architectural Lens
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
RECESSED ARCHITECTURAL / TRE22
DIMENSIONAL DATA — GRID CEILING COMPATIBILITY
For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum heights of
1½" allowed.
For hard ceiling applications, xtures must be ordered with a ange kit that wires directly into the
concealed ceiling opening for a clean nished appearance. For row congurations contact your local
Columbia Representative.
Flange kit cut out dimension for single FK22: 24 3⁄8" x 24 3⁄8"
Type G Ceiling
Mounting
Type SG Ceiling
Mounting
FK Flange Kit
Ceiling Type G placed in at T-Bar Grid Ceiling
Recessed Section (G)
4¾"
24" 24"
24"
23⁄"
23⁄"
23⁄"
23⁄"
24"
24"
End
End
For ⁄" slot grid type ceilings. Luminaire will be regressed ⁄" horizontal surface of the tee.
Ceiling Type G placed in Slot Grid or Screw Slot Ceiling
Back of Housing, Grid
23 ⁄"
½" K.O. 2X
Optional
1 ⁄" 1 ⁄"
3 ⁄"
0.875" K.O.
0.875" K.O.
4⁄"
4⁄"
11 ⁄"
DIMENSIONAL DATA — SURFACE MOUNT
NOTE: All dimensions are in inches; dimensions and specications are subject to change without notice. Please consult factory or check sample for verication.
* For Cable Mount a 2" x 3" access plate with (4) ⁄" KOs provided in place of Mounting Collar shown.
Surface Section (SM)
5⁄"
24⁄"
End View
Back of Housing, Surface Mount (SM) and Cable Mount (CM)
24⁄"
14⁄" 4⁄"
24⁄"
2¾"
1½" Thru Hole
4½" x 5" Mounting
Collar (SM Only)*
Cable Mount
(CM) Option:
(4) ¼" Thru
Holes (B)
Surface Mount
(SM) Option:
(4) ⁄" DIA KOs (A)
2¾" Ground
Screw
4"
24⁄"
5⁄"
Surface Mount:
Order SM ceiling type. Mounting
collar required for surface mounting.
(4) Mounting knock-outs, ⁄",
provided in center channel as
indicated at left, marked "A".
Cable Mount:
Order CM ceiling type. Use
CM48Y2SC3F-KIT 48" Cable Mount
Kit for 2' wide CM ceiling type
xtures. Mounting holes are
provided in diagonal straps shown at
left, marked "B".
Page 3/3 Rev. 07/26/17
TRE22
2' × 2' Transition® Enclosed High Efficiency Architectural Lens
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com