VGG19468

2014-06-24

: Pdf Vgg19468 VGG19468 pdf

Open the PDF directly: View PDF PDF.
Page Count: 5

D.....1 I.....5 N.....9 GR .....13 TR .....17 BG .....21 RO .....25
GB .....2 NL .....6 FIN .....10 CZ .....14 SK .....18 EST .....22 CN .....26
F.....3 S.....7 PL .....11 H.....15 SLO .....19 LV .....23 RUS .....27
E.....4 DK .....8 UAE .....12 P.....16 HR .....20 LT .....24
Design + Engineering GROHE Germany
Grohtherm 3000 Cosmopolitan
Grohtherm 3000 Cosmopolitan
96.516.131/ÄM 228372/08.13
19 468
19 963 (UK)
I
Please pass these instructions on to the end user of the fitting.
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
19 468
19 963 (UK)
19 468
19 963 (UK)
W
35 500
35 050 (UK)
1 2
A
B
3
DC
4
E
F
19mm
34mm
*19 332
II
Q
38 °C
8
O
N
N1
J1
G
J
G1
J2
7
I
I1
H
56
L
M
L1
L2
10
X
Z
19mm
8mm
13
W
Y
34mm
*19 332
12
W2
W1
R
V
S
9
11
2
GB
Installation
- Plaster and tile the wall, excluding the area occupied by the
mounting template. Seal any apertures in the wall so that
they are watertight to spray water.
Seal prefabricated walls with a permanently plastic
compound.
Installation of functional elements, see fold-out page I,
Figs. [1] to [4].
Shut off cold and hot water supplies.
1. Remove the mounting template, see fold-out page I, Fig. [1].
2. Unscrew closure plug (A) and plug (B), see Fig. [2].
3. Screw in sound absorber (C), see Fig. [3].
4. Grease O-ring of race (D) with the special grease supplied.
Install race (D); there is only one possible position,
see detail, Fig. [3].
5. Grease O-ring of adapter (E) with the special grease
supplied. Fasten adapter (E), see Fig. [4].
6. Install Aquadimmer (F); there is only one possible position,
see detail, Fig. [4].
Open cold and hot-water supply and check connections
for water-tightness.
Installation of escutcheon (L) and shut-off handle (N),
see fold-out page II, Figs. [5] to [7].
1. Attach sleeve (H), bracket (I) and sleeve (I1), see fold-out
page II, Fig. [5].
2. Grease seals (L1) of escutcheon mounting base (L2) with
the special grease supplied, push on escutcheon mounting
base (L2) and fasten with screws (M), see Fig. [6].
3. Attach escutcheon (L).
4. Attach stop ring (G) so that marking (G1) is at the top,
see Fig. [7].
5. Attach splined adapter (J); the faces (J1) coincide in only
one position and turn splined adapter (J) so that the
arrow (J2) points upwards.
6. Screw in mounting set (O).
7. Attach shut-off handle (N) so that marking (N1) is at the top.
If the thermostat has been installed at too great a depth,
this can be increased by 27.5mm with an extension set
(see Replacement parts, fold-out page I, Prod. no.: 47 781).
Operating shut-off handle (N)
Shut-off handle in central position = closed
Turn shut-off handle clockwise = discharge from spout
Turn shut-off handle anti-clockwise = discharge from shower
Reversed connection (hot on right - cold on left).
Replace thermostatic compact cartridge (W), see
Replacement parts, fold-out page I, Prod. no.: 47 186 (3/4”).
Adjusting
Installation of the temperature control handle (R) and
temperature adjustment, see fold-out page II, Figs. [8] and [9].
Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the thermostat.
After any maintenance operation on the thermostatic
cartridge.
1. Open the shut-off valve and check the temperature of the
water with a thermometer, see Fig. [8].
2. Turn the regulating nut (Q) clockwise or anticlockwise until
the water temperature reaches 38 °C.
3. Screw in mounting set (S), see Fig. [9].
4. Install temperature control handle (R) so that button (V) is at
the top.
Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can be
overridden by pressing button (V), see Fig. [9].
19 468: max. 80 °C
19 963 (UK): max. 46 °C
Temperature end stop [not for 19 963 (UK)]
If the temperature end stop is at 43 °C, use handle with
Prod. no.: 47 812 (see Replacement parts fold-out page I).
Prevention of frost damage
When the domestic water system is drained, thermostats must
be drained separately, since non-return valves are installed in
the hot and cold water connections.
The complete thermostat assemblies and non-return valves
must be unscrewed and removed.
Maintenance
Inspect and clean all parts, replace as necessary and lubricate
with special grease.
Shut off cold and hot water supplies.
I. Thermostatic compact cartridge (W), see fold-out page II,
Figs. [10], [11] and [12].
Loosen screw ring (Y) using a 34mm tool.
If necessary, lever out thermostatic compact cartridge (W)
via recess (W1).
Unscrew screw ring (Y).
Assemble in reverse order.
Observe the correct installation position of thermostatic
compact cartridge (W), see detail (W2).
Readjustment is necessary after every maintenance operation
on the thermostatic cartridge (see Adjusting).
II. Non-return valve (X), see fold-out page II, Figs. [10], [11]
and [13].
Assemble in reverse order.
Observe the correct installation positions.
III. Aquadimmer (Z), see fold-out page II, Figs. [10], [11]
and [13].
Assemble in reverse order.
Observe the correct installation positions.
Replacement parts, see fold-out page I (* = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
Always take care with the concealed mixer
housing, see fold-out page I.
www.grohe.com
2013 / 03 / 26
D
+49 571 3989 333
impressum@grohe.de
A
+43 1 68060
info-at@grohe.com
AUS
Argent Sydney
+(02) 8394 5800
Argent Melbourne
+(03) 9682 1231
B
+32 16 230660
info.be@grohe.com
BG
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
+99 412 497 09 74
info-az@grohe.com
CDN
+1 888 6447643
info@grohe.ca
CH
+41 448777300
info@grohe.ch
CN
+86 21 63758878
CY
+357 22 465200
info@grome.com
CZ
+420 22509 1082
grohe-cz@grohe.com
DK
+45 44 656800
grohe@grohe.dk
E
+34 93 3368850
grohe@grohe.es
EST
+372 6616354
grohe@grohe.ee
F
+33 1 49972900
marketing-fr@grohe.com
FIN
+358 10 8201100
teknocalor@teknocalor.fi
GB
+44 871 200 3414
info-uk@grohe.com
GR
+30 210 2712908
nsapountzis@ath.forthnet.gr
H
+36 1 2388045
info-hu@grohe.com
HK
+852 2969 7067
info@grohe.hk
I
+39 2 959401
info-it@grohe.com
IND
+91 124 4933000
customercare.in@grohe.com
IS
+354 515 4000
jonst@byko.is
J
+81 3 32989730
info@grohe.co.jp
KZ
+7 727 311 07 39
info-cac@grohe.com
LT
+372 6616354
grohe@grohe.ee
LV
+372 6616354
grohe@grohe.ee
MAL
+1 800 80 6570
info-singapore@grohe.com
N
+47 22 072070
grohe@grohe.no
NL
+31 79 3680133
vragen-nl@grohe.com
NZ
+09/373 4324
P
+351 234 529620
commercial-pt@grohe.com
PL
+48 22 5432640
bLXro@grohe.com.pl
RI
+62 21 2358 4751
info-singapore@grohe.com
RO
+40 21 2125050
info-ro@grohe.com
ROK
+82 2 559 0790
info-singapore@grohe.com
RP
+63 2 8041617
RUS
+7 495 9819510
info@grohe.ru
S
+46 771 141314
grohe@grohe.se
SGP
+65 6 7385585
info-singapore@grohe.com
SK
+420 22509 1082
grohe-cz@grohe.com
T
+66 2610 3685
info-singapore@grohe.com
TR
+90 216 441 23 70
GroheTurkey@grome.com
UA
+38 44 5375273
info-ua@grohe.com
USA
+1 800 4447643
us-customerservice@grohe.com
VN
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL HR KS
ME MK SLO SRB
+385 1 2911470
adria-hr@grohe.com
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
+357 22 465200
info@grome.com
IR OM
UAE YEM
+971 4 3318070
grohedubai@grome.com
Far East Area Sales Office:
+65 6311 3600
info@grohe.com.sg

Navigation menu