VGG19468
2014-06-24
: Pdf Vgg19468 VGG19468 pdf
Open the PDF directly: View PDF .
Page Count: 5
Download | |
Open PDF In Browser | View PDF |
Grohtherm 3000 Cosmopolitan 19 468 19 963 (UK) Grohtherm 3000 Cosmopolitan D .....1 GB .....2 F .....3 E .....4 I .....5 NL .....6 S .....7 DK .....8 N .....9 GR FIN .....10 CZ PL .....11 H UAE .....12 P Design + Engineering GROHE Germany 96.516.131/ÄM 228372/08.13 .....13 TR .....17 BG .....21 RO .....25 .....14 SK .....18 EST .....22 CN .....26 .....15 SLO .....19 LV .....23 RUS .....27 .....16 HR .....20 LT .....24 19 468 19 963 (UK) 19 468 19 963 (UK) 1 35 500 35 050 (UK) 2 A B W 3 4 E F Bitte diese Anleitung an den Benutzer der Armatur weitergeben! Please pass these instructions on to the end user of the fitting. S.v.p remettre cette instruction à l'utilisateur de la robinetterie! D 34 C 19mm mm *19 332 I 6 5 10 11 I I1 L2 M L1 L H 7 J1 J2 12 W G J Y O W2 G1 N1 W1 N 8 34 mm *19 332 9 13 Q Z 19mm S 38 °C II V R X m 8m Adjusting GB Installation Always take care with the concealed mixer housing, see fold-out page I. - Plaster and tile the wall, excluding the area occupied by the mounting template. Seal any apertures in the wall so that they are watertight to spray water. • Seal prefabricated walls with a permanently plastic compound. Installation of functional elements, see fold-out page I, Figs. [1] to [4]. Shut off cold and hot water supplies. 1. Remove the mounting template, see fold-out page I, Fig. [1]. 2. Unscrew closure plug (A) and plug (B), see Fig. [2]. 3. Screw in sound absorber (C), see Fig. [3]. 4. Grease O-ring of race (D) with the special grease supplied. Install race (D); there is only one possible position, see detail, Fig. [3]. 5. Grease O-ring of adapter (E) with the special grease supplied. Fasten adapter (E), see Fig. [4]. 6. Install Aquadimmer (F); there is only one possible position, see detail, Fig. [4]. Open cold and hot-water supply and check connections for water-tightness. Installation of escutcheon (L) and shut-off handle (N), see fold-out page II, Figs. [5] to [7]. 1. Attach sleeve (H), bracket (I) and sleeve (I1), see fold-out page II, Fig. [5]. 2. Grease seals (L1) of escutcheon mounting base (L2) with the special grease supplied, push on escutcheon mounting base (L2) and fasten with screws (M), see Fig. [6]. 3. Attach escutcheon (L). 4. Attach stop ring (G) so that marking (G1) is at the top, see Fig. [7]. 5. Attach splined adapter (J); the faces (J1) coincide in only one position and turn splined adapter (J) so that the arrow (J2) points upwards. 6. Screw in mounting set (O). 7. Attach shut-off handle (N) so that marking (N1) is at the top. If the thermostat has been installed at too great a depth, this can be increased by 27.5mm with an extension set (see Replacement parts, fold-out page I, Prod. no.: 47 781). Operating shut-off handle (N) Shut-off handle in central position = closed Turn shut-off handle clockwise = discharge from spout Turn shut-off handle anti-clockwise = discharge from shower Reversed connection (hot on right - cold on left). Replace thermostatic compact cartridge (W), see Replacement parts, fold-out page I, Prod. no.: 47 186 (3/4”). Installation of the temperature control handle (R) and temperature adjustment, see fold-out page II, Figs. [8] and [9]. • Before the mixer is put into service, if the mixed water temperature measured at the point of discharge varies from the specified temperature set on the thermostat. • After any maintenance operation on the thermostatic cartridge. 1. Open the shut-off valve and check the temperature of the water with a thermometer, see Fig. [8]. 2. Turn the regulating nut (Q) clockwise or anticlockwise until the water temperature reaches 38 °C. 3. Screw in mounting set (S), see Fig. [9]. 4. Install temperature control handle (R) so that button (V) is at the top. Temperature limitation The safety stop limits the temperature range to 38 °C. If a higher temperature is desired, the 38 °C limit can be overridden by pressing button (V), see Fig. [9]. 19 468: max. 80 °C 19 963 (UK): max. 46 °C Temperature end stop [not for 19 963 (UK)] If the temperature end stop is at 43 °C, use handle with Prod. no.: 47 812 (see Replacement parts fold-out page I). Prevention of frost damage When the domestic water system is drained, thermostats must be drained separately, since non-return valves are installed in the hot and cold water connections. The complete thermostat assemblies and non-return valves must be unscrewed and removed. Maintenance Inspect and clean all parts, replace as necessary and lubricate with special grease. Shut off cold and hot water supplies. I. Thermostatic compact cartridge (W), see fold-out page II, Figs. [10], [11] and [12]. • Loosen screw ring (Y) using a 34mm tool. • If necessary, lever out thermostatic compact cartridge (W) via recess (W1). • Unscrew screw ring (Y). Assemble in reverse order. Observe the correct installation position of thermostatic compact cartridge (W), see detail (W2). Readjustment is necessary after every maintenance operation on the thermostatic cartridge (see Adjusting). II. Non-return valve (X), see fold-out page II, Figs. [10], [11] and [13]. Assemble in reverse order. Observe the correct installation positions. III. Aquadimmer (Z), see fold-out page II, Figs. [10], [11] and [13]. Assemble in reverse order. Observe the correct installation positions. Replacement parts, see fold-out page I (* = special accessories). Care For directions on the care of this fitting, refer to the accompanying Care Instructions. 2 D ✆ +49 571 3989 333 impressum@grohe.de A ✆ +43 1 68060 info-at@grohe.com AUS Argent Sydney ✆ +(02) 8394 5800 Argent Melbourne ✆ +(03) 9682 1231 B ✆ +32 16 230660 info.be@grohe.com BG ✆ +359 2 9719959 grohe-bulgaria@grohe.com CAU ✆ +99 412 497 09 74 info-az@grohe.com CDN ✆ +1 888 6447643 info@grohe.ca CH ✆ +41 448777300 info@grohe.ch CN ✆ FIN ✆ +358 10 8201100 teknocalor@teknocalor.fi GB ✆ +44 871 200 3414 info-uk@grohe.com GR ✆ +30 210 2712908 nsapountzis@ath.forthnet.gr H ✆ +36 1 2388045 info-hu@grohe.com HK ✆ +852 2969 7067 info@grohe.hk I ✆ +39 2 959401 info-it@grohe.com IND ✆ +91 124 4933000 customercare.in@grohe.com IS ✆ +354 515 4000 jonst@byko.is J ✆ +81 3 32989730 info@grohe.co.jp +86 21 63758878 CY ✆ +357 22 465200 KZ ✆ +7 727 311 07 39 info-cac@grohe.com info@grome.com CZ ✆ +420 22509 1082 LT ✆ +372 6616354 grohe@grohe.ee grohe-cz@grohe.com DK ✆ +45 44 656800 LV ✆ +372 6616354 grohe@grohe.ee grohe@grohe.dk E ✆ +34 93 3368850 MAL ✆ +1 800 80 6570 info-singapore@grohe.com grohe@grohe.es EST ✆ +372 6616354 N ✆ +47 22 072070 grohe@grohe.no grohe@grohe.ee F ✆ +33 1 49972900 marketing-fr@grohe.com NL ✆ +31 79 3680133 vragen-nl@grohe.com NZ ✆ +09/373 4324 P ✆ +351 234 529620 commercial-pt@grohe.com PL ✆ +48 22 5432640 bLXro@grohe.com.pl www.grohe.com BiH ME MK SLO SRB HR KS ✆ +385 1 2911470 adria-hr@grohe.com Eastern Mediterranean, Middle East - Africa Area Sales Office: ✆ +357 22 465200 info@grome.com RI ✆ +62 21 2358 4751 info-singapore@grohe.com RO ✆ +40 21 2125050 info-ro@grohe.com ROK ✆ +82 2 559 0790 info-singapore@grohe.com RP ✆ +63 2 8041617 RUS ✆ +7 495 9819510 info@grohe.ru S ✆ +46 771 141314 grohe@grohe.se SGP ✆ +65 6 7385585 info-singapore@grohe.com SK ✆ +420 22509 1082 grohe-cz@grohe.com T ✆ +66 2610 3685 info-singapore@grohe.com TR ✆ +90 216 441 23 70 GroheTurkey@grome.com UA ✆ +38 44 5375273 info-ua@grohe.com USA ✆ +1 800 4447643 us-customerservice@grohe.com VN ✆ +84 8 5413 6840 info-singapore@grohe.com 2013 / 03 / 26 AL IR OM UAE YEM ✆ +971 4 3318070 grohedubai@grome.com Far East Area Sales Office: ✆ +65 6311 3600 info@grohe.com.sg
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2013:08:27 10:53:29Z Modify Date : 2014:06:20 08:53:08+01:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 5.0.5 (Windows) Metadata Date : 2014:06:20 08:53:08+01:00 Format : application/pdf Document ID : uuid:508b9d56-f7fd-436c-919b-d2a431aa4393 Instance ID : uuid:dcb781cd-b06c-44d3-bd46-de9675d2a2ef Page Layout : SinglePage Page Mode : UseThumbs Page Count : 5EXIF Metadata provided by EXIF.tools