E ZB 01 EMC Report
Zb-01 Emc Report ZB-01_EMC_Report ZB-01_EMC_Report CertsReports 177344 ProductFiles assets.mhint
Zb-01 Emc Report ZB-01_EMC_Report ZB-01_EMC_Report CertsReports 177320 ProductFiles assets.mhint
Zb-01 Emc Report ZB-01_EMC_Report ZB-01_EMC_Report CertsReports 177313 ProductFiles assets.mhint
Zb-01 Emc Report ZB-01_EMC_Report ZB-01_EMC_Report CertsReports 177337 ProductFiles assets.mhint
2016-04-05
: Pdf Zb-01 Emc Report ZB-01_EMC_Report CertsReports 177351 ProductFiles
Open the PDF directly: View PDF
.
Page Count: 59
| Download | |
| Open PDF In Browser | View PDF |
EMC TEST REPORT Issued Date: 2009-09-25 Report No. : Equipment : I0808002E AC/DC TRAVEL CHARGER Model No. : ZB-01-XXYYZ(XX indicates output Voutage,YY indicates output current 10W max,Z=EU,EN;EU indicate for EU plug,EN indicate for BS plug Input: 100-240Vac 50/60Hz Output: Applicant : See Page 9 ZHONGBAI ELECTRONIC CO., LTD. Address : NO.9, YingCheng 1ST ROAD ,XIABIAN VILLAGE,CHANGAN TOWN DONGGUAN CITY CHINA Tested by: ATT Product Service Co., Ltd Data of Test: 09/10/2009 –09/18/ 2009 Testing Engineer : Reviewer : Authorized Signatory : Testing Laboratory:ATT Product Service Co., Ltd Address : : 2F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China TEL: 0769 8509 8000 FAX: Website: http://www.attps.cn E-mail: att@attps.cn 0769 8509 8777 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 1 of 59 Declaration ATT represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. ATT's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. ATT shall have no liability for any declarations, inferences or generalizations drawn by the client or others from ATT issued reports. ATT’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ATT-self, extracts from the test report shall not be reproduced except in full with ATT’s authorized written approval. ATT’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 2 of 59 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 MEASUREMENT UNCERTAINTY 8 2.1 GENERAL DESCRIPTION OF EUT 9 2.2 DESCRIPTION OF TEST MODES 10 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.4 DESCRIPTION OF SUPPORT UNITS 12 3 . EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION 3.1.2 MEASUREMENT INSTRUMENTS LIST 3.1.3 TEST PROCEDURE 3.1.4 DEVIATION FROM TEST STANDARD 3.1.5 TEST SETUP 3.1.6 EUT OPERATING CONDITIONS 3.1.7 TEST RESULTS 13 13 13 14 14 14 14 15 3.2 RADIATED EMISSION MEASUREMENT 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 3.2.2 MEASUREMENT INSTRUMENTS LIST 3.2.3 TEST PROCEDURE 3.2.4 DEVIATION FROM TEST STANDARD 3.2.5 TEST SETUP 3.2.6 EUT OPERATING CONDITIONS 3.2.7 TEST RESULTS 19 19 20 20 20 21 21 22 3.3 HARMONICS CURRENT MEASUREMENT 3.3.1 LIMITS OF HARMONICS CURRENT MEASUREMENT 3.3.2 MEASUREMENT INSTRUMENTS LIST 3.3.3 TEST PROCEDURE 3.3.4 DEVIATION FROM TEST STANDARD 3.3.5 TEST SETUP 3.3.6 EUT OPERATING CONDITIONS 3.3.7 TEST RESULTS 26 26 26 27 27 27 27 28 3.4 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 3.4.1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKSMEASUREMENT 3.4.2 MEASUREMENT INSTRUMENTS LIST 3.4.3 TEST PROCEDURE 3.4.4 DEVIATION FROM TEST STANDARD 31 31 31 31 31 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 3 of 59 Table of Contents 3.4.5 TESTSETUP 3.4.6 EUT OPERATING CONDITIONS 3.4.7 TEST RESULTS 4 . EMC IMMUNITY TEST Page 32 32 33 34 4.1 STANDARD COMPLIANCE/SERVRITY LEVEL/CRITERIA 34 4.2 GENERAL PERFORMANCE CRITERIA 35 4.3 GENERAL PERFORMANCE CRITERIA TEST SETUP 35 4.4 ESD TESTING 4.4.1 TEST SPECIFICATION 4.4.2 MEASUREMENT INSTRUMENTS 4.4.3 TEST PROCEDURE 4.4.4 DEVIATION FROM TEST STANDARD 4.4.5 TEST SETUP 4.4.6 TEST RESULTS 36 36 36 36 37 37 38 4.5 RS TESTING 4.5.1 TEST SPECIFICATION 4.5.2 MEASUREMENT INSTRUMENTS 4.5.3 TEST PROCEDURE 4.5.4 DEVIATION FROM TEST STANDARD 4.5.5 TEST SETUP 4.5.6 TEST RESULTS 39 39 39 39 39 40 41 4.6 EFT/BURST TESTING 4.6.1 TEST SPECIFICATION 4.6.2 MEASUREMENT INSTRUMENTS 4.6.3 TEST PROCEDURE 4.6.4 DEVIATION FROM TEST STANDARD 4.6.5 TEST SETUP 4.6.6 TEST RESULTS 42 42 42 42 42 43 44 4.7 SURGE TESTING 4.7.1 TEST SPECIFICATION 4.7.2 MEASUREMENT INSTRUMENTS 4.7.3 TEST PROCEDURE 4.7.4 DEVIATION FROM TEST STANDARD 4.7.5 TEST SETUP 4.7.6 TEST RESULTS 45 45 45 45 46 46 47 4.8 INJECTION CURRENT TESTING 4.8.1 TEST SPECIFICATION 4.8.2 MEASUREMENT INSTRUMENTS 4.8.3 TEST PROCEDURE 4.8.4 DEVIATION FROM TEST STANDARD 48 48 48 48 48 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 4 of 59 Table of Contents 4.8.5 TEST SETUP 4.8.6 TEST RESULTS Page 49 50 4.9 POWER FREQUENCY MAGNETIC FIELD TESTING 4.9.1 TEST SPECIFICATION 4.9.2 MEASUREMENT INSTRUMENTS 4.9.3 TEST PROCEDURE 4.9.4 DEVIATION FROM TEST STANDARD 4.9.5 TEST SETUP 4.9.6 TEST RESULTS 51 51 51 51 51 52 53 4.10 VOLTAGE INTERRUPTION/DIPS TESTING 4.10.1 TEST SPECIFICATION 4.10.2 MEASUREMENT INSTRUMENTS 4.10.3 TEST PROCEDURE 4.10.4 DEVIATION FROM TEST STANDARD 4.10.5 TEST SETUP 4.10.6 TEST RESULTS 54 54 54 54 54 55 56 5 . EUT TEST PHOTO 57 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 5 of 59 1. CERTIFICATION Equipment Trade Name Model No. Applicant Data of Test Test Item Standards : : : : : AC/DC TRAVEL CHARGER N/A ZB-01 ZHONGBAI ELECTRONIC CO., LTD. 09/10/2009 –09/18/ 2009 : ENGINEERING SAMPLE : EN 55022:1998+A1: 2000+A2: 2006 EN 55024:1998+A1: 2000+A2: 2003 EN 61000-3-2:2006 EN 61000-3-3:1995+A1+A2 IEC 61000-4-2:1995+A1+A2 IEC 61000-4-3: 2006 IEC 61000-4-4: 2006 IEC 61000-4-5: 2006 IEC 61000-4-6: 1996+A1 IEC 61000-4-8: 1994+A1 IEC 61000-4-11: 2004 The above equipment has been tested and found compliance with the requirement of the relative standards by ATT Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-EMC-1-0609C001) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of CNAS according to the ISO-17025 quality assessment standard and technical standard(s). ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 6 of 59 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: EMC Emission Standard Test Item Limit Judgment Conducted Emission Class B PASS Radiated Emission Class B PASS EN 61000-3-2:2006 Harmonic Current Emission Class A PASS EN 61000-3-3:1995 +A1+A2 Voltage Fluctuations & Flicker ------ PASS EN 55022:1998 +A1+A2 :2006 Section IEC 61000-4-2:1995 +A1+A2 EMC Immunity (EN 55024: 1998+A1:2001+A2:2003) Performance Test Item Criteria Judgment Electrostatic Discharge B PASS IEC 61000-4-3:2006 RF electromagnetic field A PASS IEC 61000-4-4:2004 Fast transients B PASS Surges B PASS Injected Current A PASS IEC 61000-4-8:1994+A1 Power Frequency Magnetic Field A PASS IEC 61000-4-11:2004 Volt. Interruptions Volt. Dips B/C/C NOTE (3) PASS IEC 61000-4-5: 1995 +A1+A2 IEC 61000-4-6: 1996 +A1+A2 Remark Remark NOTE: (1)” N/A” denotes test is not applicable in this Test Report (2) The power consumption of EUT is less than 75W and no Limits apply. (3) Voltage dip: >95% reduction – Performance Criteria B Voltage dip: 30% reduction – Performance Criteria C Voltage Interruption: >95% reduction – Performance Criteria C ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 7 of 59 2.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 A. Conducted Measurement : Test Site C01 Method ANSI Measurement Frequency Range 150 KHz ~ 30MHz U,(dB) 1.94 NOTE U,(dB) NOTE B. Radiated Measurement : Test Site OS02 Method Measurement Frequency Range ANSI 30MHz ~ 200MHz 30MHz ~ 200MHz 200MHz ~ 1,000MHz 200MHz ~ 1,000MHz Ant. H/V V H V H 3.82 3.60 3.86 3.94 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 8 of 59 2.2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment : AC/DCTRAVEL CHARGER Model No.: ZB-01 Model Difference: N/A Input: 100-240Vac 50/60Hz Output: See Page 9 Test Sample: ZB-01 EUT Modification(s): N/A Factory: ZHONGBAI ELECTRONIC CO., LTD. Factory Address: NO.9 Yingcheng 1st Rd,Xiabian.Changan Town Dongguan City,GuangDong Prorince China Model No. Input Output Transformer ZB-01-42~55YYZ DC4.2~5.5V 2A/10W (max) EE1910-ZB40 ZB-01-56~68YYZ DC5.6~6.8V 1.78A/10W(max) EE1910-ZB50 ZB-01-70~82YYZ DC7.0~8.2V 1.42A/10W(max) EE1910-ZB60 ZB-01-83~95YYZ DC8.3~9.5V 1.2A/10W(max) EE1910-ZB70 ZB-01-12YYZ DC12V 0.8A(max) EE1910-ZB80 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 9 of 59 2.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Description Mode 1 FULL LOAD For Conducted Test Final Test Mode Description Mode 1 FULL LOAD For Radiated Test Final Test Mode Description Mode 1 FULL LOAD For Harmonics / Flicks Test Final Test Mode Description Mode 1 FULL LOAD For EMS Test Final Test Mode Description Mode 1 FULL LOAD ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 10 of 59 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED C-1 E-1 EUT E-2 Dummy Load C-1 Power Cable ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 11 of 59 2.4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Mfr/Brand Model/Type No. E-1 AC ADAPTER N/A E-2 Dummy Load N/A N/A Item Shielded Type Ferrite Core Length C-1 NO NO 1.5M ZB-01-5020EU FCC ID Series No. Note N/A N/A EUT N/A N/A Note Note: (1) (2) Unless otherwise marked as ※ in 『 Remark 』 column, ATT consigns the support equipment to the tested system. For detachable type I/O cable should be specified the length in cm in『Length』column. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 12 of 59 3. EMC EMISSION TEST 3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION FREQUENCY (MHz) (Frequency Range 150KHz-30MHz) Class A (dBuV) Class B (dBuV) Quasi-peak Average Quasi-peak Average 0.15 -0.5 79.00 66.00 66 - 56 * 56 - 46 * 0.50 -5.0 73.00 60.00 56.00 46.00 5.0 -30.0 73.00 60.00 60.00 50.00 Note: (1) The tighter limit applies at the band edges. (2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 3.1.2 MEASUREMENT INSTRUMENTS LIST Item Kind of Equipment 1 LISN 2 Pulse Limiter 3 4 Manufacturer SCHWARZBECK MESS-ELEKTRONIK Type No. Serial No. Calibrated until NSLK 8127 8127-432 06/12/2009 Agilent 11947A 3107A03668 06/12/2009 Test Cable N/A C01 N/A 06/12/2009 EMI Test Receiver SCHWARZBECK MESS-ELEKTRONIK FCKL1528 1528-184 06/12/2009 Remark: ” N/A” denotes No Model No. , Serial No. or No Calibration specified. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 13 of 59 3.1.3 TEST PROCEDURE a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item –EUT Test Photos. 3.1.4 DEVIATION FROM TEST STANDARD No deviation 3.1.5 TEST SETUP 3.1.6 EUT OPERATING CONDITIONS The EUT exercise program used during radiated and/or conducted emission measurement was designed to exercise the various system components in a manner similar to a typical use. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 14 of 59 3.1.7 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020EU Temperature: 26℃ Relative Humidity: 48 % Pressure: 1008 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Freq. Terminal (MHz) 0.17 0.25 L/N Line Line Measured(dBuV) QP-Mode 62.41 54.26 AV-Mode 52.21 47.05 Limits( dBuV) QP-Mode 65.03 61.69 AV-Mode 55.03 51.69 Margin (dB) -2.62 -4.64 Note (QP) (AV) Remark (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。 Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=1MHz,VBW=10Hz, Swp. Time =0.3 sec./MHz。 (2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。 (3) Measuring frequency range from 150KHz to 30MHz。 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 15 of 59 Job No.: Z B 09103415 Phase: Standard: FCC Part15 CE-Class B_QP Power Source: AC 230V/50 Test item: Date: 09/09/11/ Temp.( Conduction Test C)/Hum.(%) 25.5 EUT: ADAPTER Mode: FULL LOAD Model: C / 51 % L1 Time: 9/27/34 Engineer Signature: ZB-01-5020 Note: No. 1 Freq. Reading (MHz) (dBuV) 0.1539 49.07 Factor (dB) 10.64 Result (dBuV) 59.71 Limit Margin Detector dBuV (dB) 65.78 -6.07 QP 2 0.1539 28.26 10.64 38.90 55.78 -16.88 3 0.1940 43.33 10.67 54.00 63.86 4 0.1940 25.01 10.67 35.68 53.86 -18.18 AVG 5 1.5980 26.16 11.20 37.36 56.00 -18.64 QP 6 1.5980 15.72 11.20 26.92 46.00 -19.08 AVG -9.86 Remark AVG QP ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 16 of 59 EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 48 % Pressure: 1008 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Freq. Terminal (MHz) 0.17 0.25 L/N Neutral Neutral Measured(dBuV) QP-Mode 62.77 53.76 AV-Mode 50.82 45.92 Limits( dBuV) QP-Mode 64.92 61.50 AV-Mode 54.92 51.50 Margin (dB) -2.15 -5.58 Note (QP) (AV) Remark (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。 Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=1MHz,VBW=10Hz, Swp. Time =0.3 sec./MHz。 (2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of Interference Voltage Measured。 (3) Measuring frequency range from 150KHz to 30MHz。 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 17 of 59 Job No.: Z B 09103415 Phase: Standard: FCC Part15 CE-Class B_QP Power Source: AC 230V/50 Test item: Date: 09/09/ Temp.( EUT: Mode: Model: Conduction Test C)/Hum.(%) 25.5 C / 51 % N Time: 9/29/30 ADAPTER Engineer Signature: FULL LOAD ZB-01-5020 Note: No. 1 Freq. Reading (MHz) (dBuV) 0.1940 40.65 Factor (dB) 10.67 Result (dBuV) 51.32 Limit Margin Detector dBuV (dB) 63.86 -12.54 QP 2 0.1940 23.15 10.67 33.82 53.86 -20.04 AVG 3 0.3700 35.53 10.72 46.25 58.50 -12.25 QP 4 0.3700 18.32 10.72 29.04 48.50 -19.46 AVG 5 1.8620 25.38 11.23 36.61 56.00 -19.39 QP 6 1.8620 15.04 11.23 26.27 46.00 -19.73 AVG Remark ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 18 of 59 3.2 RADIATED EMISSION MEASUREMENT 3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT (Below 1000MHz) Class A (at 10m) Class B (at 10m) dBuV/m dBuV/m 30 – 230 40 30 230 – 1000 47 37 FREQUENCY (MHz) Notes: (1) The limit for radiated test was performed according to as following: CISPR 22/ FCC PART 15B /ICES-003. (2) The tighter limit applies at the band edges. (3) Emission level (dBuV/m)=20log Emission level (uV/m). LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz) FREQUENCY (MHz) Above 1000 Class A (dBuV/m) (at 3m) Class B (dBuV/m) (at 3m) PEAK AVERAGE PEAK AVERAGE 80 60 74 54 Notes: (1) The limit for radiated test was performed according to FCC PART 15B. (2) The tighter limit applies at the band edges. (3) Emission level (dBuV/m)=20log Emission level (uV/m). FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators) Highest frequency generated or Upper frequency of measurement used in the device or on which the device operates or tunes (MHz) Range (MHz) Below 1.705 30 1.705 – 108 1000 108 – 500 2000 500 – 1000 50000 5 harmonic of the highest frequency or 40 GHz, whichever is lower th Above 1000 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 19 of 59 3.2.2 MEASUREMENT INSTRUMENTS LIST Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Log-Bicon Antenna SCHWARZBECK VuLB9168 9168-192 06/29/2009 2 Test Cable N/A 10M_OS01 N/A 06/29/2009 3 Test Cable N/A C01-1/-2 N/A 06/29/2009 4 Pre-Amplifier HP 8447D 2944A09491 06/29/2009 5 Spectrum Analyzer HP 8591A 10201103 06/29/2009 6 Test Receiver R&S ESVS 10 825475/002 06/29/2009 7 Antenna Mast N/A N/A N/A N/A 8 Turn Table N/A N/A N/A N/A Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 3.2.3 TEST PROCEDURE a. The measuring distance of at 10 m shall be used for measurements at frequency up to 1GHz. For frequencies above 1GHz, any suitable measuring distance may be used. b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m or 10 meter open area test site. The table was rotated 360 degrees to determine the position of the highest radiation. c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. f. For the actual test configuration, please refer to the related Item –EUT Test Photos. 3.2.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 20 of 59 3.2.5 TEST SETUP 3.2.6 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special operating condition is specified in the follows during the testing. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 21 of 59 3.2.7 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 48 % Pressure: 1009 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Freq. (MHz) 49.40 68.80 Ant. H/V v v Reading(RA) Corr.Factor (CF) Measured(FS) (dBuV) (dB) (dBuV/m ) 35.35 -6.89 28.46 33.02 -5.55 27.47 Limits(QP) (dBuV/m) 40.00 40.00 Margin (dB) - 11.54 - 12.53 Note Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。 (2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measure-ment didn‘t perform。 (3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not how in table。 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 22 of 59 Job No.: Z B 09103415 Polarization: Standard: FCC Part15 RE-Class B_30-1000MHz Power Source: AC 230V/50H Test item: Date: 2009-09-11 Temp.( EUT: Radiation Test C)/Hum.(%) 25.5 开关电源 Mode: FULL LOAD Model: ZB-01-5020 C / 51 % Horizontal Time: 9:56:24 Engineer Signature: Distance: 3m Note: 1 Freq. Reading (MHz) (dBuV/m) 30.0000 6.60 Factor (dB) 17.40 2 135.9163 15.05 12.98 28.03 43.50 -15.47 peak 3 156.9765 10.98 14.08 25.06 43.50 -18.44 peak No. Result Limit Margin Detector (dBuV/m) (dBuV/m) (dB) 24.00 40.00 -16.00 peak Remark ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 23 of 59 EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 48% Pressure: 1009 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Freq. (MHz) 44.55 182.77 Ant. H/V H H Reading(RA) Corr.Factor (CF) Measured(FS) (dBuV) (dB) (dBuV/m ) 44.65 -15.92 28.73 38.65 -11.09 27.56 Limits(QP) (dBuV/m) 40.00 40.00 Margin (dB) - 11.27 - 12.44 Note Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./MHz。 (2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measure-ment didn‘t perform。 (3) Measuring frequency range from 30MHz to 1000MHz。 (4) If the peak scan value lower limit more than 20dB, then this signal data does not how in table。 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 24 of 59 Job No.: ZB09103415 Polarization: Standard: FCC Part15 RE-Class B_30-1000MHz Power Source:AC 230V/50Hz Test item: Date: 09/09/11/ Temp.( Radiation Test C)/Hum.(%) 25.5 EUT: 开关电源 Mode: FULL LOAD Model: ZB-01-5020 C / 51 % Vertical Time: 9/34/27 Engineer Signature: Distance: 3m Note: 1 Freq. Reading (MHz) (dBuV/m) 30.0000 12.03 Factor (dB) 17.40 2 134.4911 12.91 No. 9.10 Result Limit Margin Detector (dBuV/m) (dBuV/m) (dB) 29.43 40.00 -10.57 QP 22.01 43.50 -21.49 Remark QP ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 25 of 59 3.3 HARMONICS CURRENT MEASUREMENT 3.3.1 LIMITS OF HARMONICS CURRENT MEASUREMENT IEC 555-2 Table - I Table - II Equipment Harmonic Max. Permissible Equipment Harmonic Max. Permissible Category Order Harmonic Current Category Order Harmonic Current n (in Ampers) n (in Ampers) Non Portable Tools or TV Receivers Odd Harmonics 2.30 3 1.14 5 0.77 7 0.40 9 0.33 11 0.21 13 0.15.15/n 15≤n≤39 Even Harmonics 1.08 2 0.43 4 0.30 8 0.23.8/n 8≤n≤40 TV Receivers Odd Harmonics 0.80 3 0.60 5 0.45 7 0.30 9 0.17 11 0.12 13 0.10.15/n 15≤n≤39 Even Harmonics 0.30 2 0.15 4 0.05 DC EN 61000-3-2/IEC 61000-3-2 Equipment Max. Permissible Equipment Harmonic Max. Permissible Category Harmonic Current Category Order Harmonic Current Class A (in Ampers) n Same as Limits Specified in 4-2.1, Table - I, but only odd harmonics required 3 5 7 9 11 13≤n≤39 Class D (in A) (mA/w) 3.4 2.30 1.9 1.14 1.0 0.77 0.5 0.40 0.35 0.33 see 3.85/n Table I only odd harmonics required 3.3.2 MEASUREMENT INSTRUMENTS LIST Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Harmonic & Flicker California PACS-1 72344 06/29/2009 2 Power Source California 3001iX 56309 06/29/2009 ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 26 of 59 3.3.3 TEST PROCEDURE a. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the maximum harmonic components under normal operating conditions. b. The classification of EUT is according to section 5 of EN 61000-3-2: 2000.The EUT is classified as follows: Class A: Balanced three-phase equipment, Household appliances excluding equipment as Class D, Tools excluding portable tools, Dimmers for incandescent lamps, audio equipment, equipment not specified in one of the three other classes. Class B: Portable tools. Portable tools.; Arc welding equipment which is not professional equipment. Class C: Lighting equipment. Class D: Equipment having a specified power less than or equal to600 W of the following types: Personal computers and personal computer monitors and television receivers. c. The correspondent test program of test instrument to measure the current harmonics emanated from EUT is chosen. The measure time shall be not less than the time necessary for the EUT to be exercised. d. For the actual test configuration, please refer to the related item –EUT Test Photos. 3.3.4 DEVIATION FROM TEST STANDARD No deviation 3.3.5 TEST SETUP 3.3.6 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special operating condition is specified in the follows during the testing. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 27 of 59 3.3.7 TEST RESULTS Harmonics – Class-D per Ed. 2.1(Run time) EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 48% Pressure: 1009 hPa Test Power : AC 230V/50Hz Test Mode : Full Load 0.15 300 0.10 200 0.05 100 0.00 0 -0.05 -100 -0.10 -200 -0.15 -300 Harmonics and ClassA limit line Voltage (Volts) Current (Amps) Current & voltage waveforms European Limits 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 4 Test result: Pass 8 12 16 20 24 Harmonic # 28 32 36 40 Worst harmonic was #25with 0.94% of the limit. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 28 of 59 Current Test Result Summary (Run time) Model No. : ZB-01-5020 Temperature: AC ADAPTER 26℃ Relative Humidity: 48 % Pressure: 1009 hPa Test Power : AC 230V/50Hz EUT: Highest parameter values during test: V_RMS (Volts): 230.03 Frequency(Hz): 50.00 I_Peak (Amps): 0.055 I_RMS (Amps): 0.009 I_Fund (Amps): 0.003 Crest Factor: 7.075 Power (Watts): 15.53 Power Factor: 0.318 Test Mode: Full Load Harm# Harms(avg) 100%Limit %of Limit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 0.001 0.002 0.001 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 1.080 2.300 0.430 1.140 0.300 0.770 0.230 0.400 0.184 0.330 0.153 0.210 0.131 0.150 0.115 0.132 0.102 0.118 0.092 0.107 0.084 0.098 0.077 0.090 0.071 0.083 0.066 0.078 0.061 0.073 0.058 0.068 0.054 0.064 0.051 0.061 0.048 0.058 0.046 0.1 0.1 0.2 0.2 0.1 0.2 0.0 0.4 0.1 0.5 0.1 0.8 0.1 1.1 0.0 1.2 0.1 1.2 0.1 1.3 0.1 1.3 0.1 1.3 0.1 1.3 0.1 1.3 0.1 1.3 0.1 1.2 0.1 1.2 0.1 1.1 0.1 1.0 0.1 Harms(max) 150%Limit %of Limit 0.001 0.003 0.001 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.002 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 0.001 0.000 1.620 3.450 0.645 1.710 0.450 1.155 0.345 0.600 0.276 0.495 0.230 0.315 0.197 0.225 0.173 0.199 0.153 0.178 0.138 0.161 0.125 0.147 0.115 0.135 0.106 0.125 0.099 0.116 0.092 0.109 0.086 0.102 0.081 0.096 0.077 0.091 0.073 0.087 0.069 0.08 0.09 0.15 0.13 0.10 0.19 0.04 0.32 0.08 0.38 0.10 0.57 0.08 0.76 0.04 0.82 0.08 0.88 0.08 0.91 0.06 0.93 0.06 0.94 0.07 0.94 0.06 0.94 0.06 0.91 0.07 0.88 0.08 0.83 0.08 0.78 0.08 0.71 0.08 Status Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 29 of 59 Voltage Source Verification Data (Run time) Model No. : ZB-01-5020 Temperature: AC ADAPTER 26℃ Relative Humidity: 48 % Pressure: 1009 hPa Test Power : AC 230V/50Hz EUT: Highest parameter values during test: V_RMS (Volts): 230.03 Frequency(Hz): 50.00 I_Peak (Amps): 0.055 I_RMS (Amps): 0.009 I_Fund (Amps): 0.003 Crest Factor: 7.075 Power (Watts): 15.23 Power Factor: 0.318 Test Mode: Full Load Harm# 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Harmonics V-rms Limit V-rms % of Limit Status 0.160 0.598 0.104 0.077 0.057 0.057 0.027 0.062 0.024 0.032 0.024 0.014 0.020 0.013 0.015 0.014 0.017 0.018 0.019 0.013 0.015 0.015 0.010 0.007 0.007 0.009 0.006 0.011 0.005 0.011 0.007 0.007 0.008 0.012 0.009 0.010 0.009 0.009 0.010 0.460 2.070 0.460 0.920 0.460 0.690 0.460 0.460 0.460 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 0.230 34.75 28.90 22.50 8.41 12.40 8.22 5.98 13.57 5.31 14.01 10.22 6.12 8.61 5.78 6.39 6.18 7.21 7.76 8.46 5.46 6.40 6.71 4.31 2.87 3.04 4.07 2.39 4.83 2.37 4.95 2.85 3.25 3.35 5.28 3.81 4.46 3.91 3.80 4.49 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 30 of 59 3.4 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 3.4.1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKSMEASUREMENT Limits Tests IEC555-3 Descriptions IEC/EN 61000-3-2 Pst ≤ 1.0, Tp= 10 min. ≤ 1.0, Tp= 10 min. Short Term Flicker Indicator Plt N/A ≤ 0.65, Tp=2 hr. Long Term Flicker Indicator dc ≤3% ≤ 3.3 % Relative Steady-State V-Chang dmax ≤4% ≤4% Maximum Relative V-change d (t) N/A ≤ 3.3% for > 500 ms Relative V-change characteristic 3.4.2 MEASUREMENT INSTRUMENTS LIST Item Manufacturer Type No. Serial No. Calibrated until 1 Harmonic & Flicker Kind of Equipment California PACS-1 72344 06/29/2009 2 Power Source California 3001iX 56309 06/29/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 3.4.3 TEST PROCEDURE a. Harmonic Current Test: Test was performed according to the procedures specified in Clause 5.0 of IEC555-2 and/or Sub-clause 6.2 of IEC/EN 61000-3-2 depend on which standard adopted for compliance measurement. b. Fluctuation and Flickers Test: Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC/EN 61000-3-3 depend on which standard adopted for compliance measurement. c. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct measurement using flicker-meter. d. For the actual test configuration, please refer to the related Item –EUT Test Photos. 3.4.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 31 of 59 3.4.5 TESTSETUP 3.4.6 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special operating condition is specified in the follows during the testing. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 32 of 59 3.4.7 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 25 ℃ Relative Humidity: 56 % Pressure: 1009 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Pst i and limit line European Limits 1.00 0.75 0.50 0.25 0.00 10:12:18 Time is too short for Plt plot Parameter values recorded during the test: Vrms at the end of test (Volt): 229.67 Highest dt (%): Time(mS) > dt: 0.00 Test limit (%): 0.0 Test limit (mS): 3.30 PASS 500.0 PASS Highest dc (%): 0.00 Test limit (%): 3.30 PASS Highest dmax (%): 0.00 Test limit (%): 4.00 PASS Highest Pst (10 min. period): 0.001 Test limit: 1.000 PASS Highest Plt (2 hr. period): 0.001 Test limit: 0.650 PASS ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 33 of 59 4. EMC IMMUNITY TEST 4.1 STANDARD COMPLIANCE/SERVRITY LEVEL/CRITERIA Tests Standard No. 1. ESD IEC/EN 61000-4-2 2. RS IEC/EN 61000-4-3 3. EFT/Burst IEC/EN 61000-4-4 4. Surges IEC/EN 61000-4-5 5 Injected Current IEC/EN 61000-4-6 6. Power Frequency Magnetic Field IEC/EN 61000-4-8 7. Volt. Interruptions Volt. Dips IEC/EN 61000-4-11 * Remark: TEST SPECIFICATION Level 8KV air discharge 4KV contact discharge 4KV HCP discharge 4KV VCP discharge 80 MHz to 1000 MHz 3V/m(rms), 1 KHz, 80%, AM modulated 900 +/- 5MHz 3V/m(rms), Duty cycle 50% Repetition frequency:200Hz 1.0KV(peak) 5/50ns Tr/Th 5KHz Repetition Freq. 0.5 KV(peak) 5/50ns Tr/Th 5KHz Repetition Freq. 1 KV(5P/5N) 1.2/50(8/20) Tr/Th us 2 KV(5P/5N) 1.2/50(8/20) Tr/Th us 0.15 MHz to 80 MHz 3V(rms), 1KHz 80%, AM Modulated 150Ω source impedance 0.15 MHz to 80 MHz 3V(rms), 1KHz 80%, AM Modulated 150Ω source impedance 0.15 MHz to 80 MHz 3V(rms), 1KHz 80%, AM Modulated 150Ω source impedance 50 Hz, 1A/m Voltage dip>95% / 30% Interruption>95% Test Mode Test Ports Perform. Criteria Direct Mode B Indirect Mode B Remark A Enclosure B AC ADAPTER Port B CTL/Signal Data Line Port B L-N B L-PE N-PE B CTL/Signal Port A AC Power Port A DC Power Port A Enclosure A <5% / 70% <5% B/C N/A N/A N/A C (1) “N/A”: denotes test is not applicable in this Test Report. : ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 34 of 59 4.2 GENERAL PERFORMANCE CRITERIA According to EN55024:1998+A1:2001+A2:2003 standard, the general performance criteria as following: Criterion A Criterion B Criterion C The equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. After the test, the equipment shall continue to operate as intended without operator Intervention. No degradation of performance or loss of function is allowed, after the application of the phenomenon below a performance level specified by the manufacturer, when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operating state if stored data allowed to persist after the test. If the minimum performance level (or the permissible performance loss ) is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer’s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost. 4.3 GENERAL PERFORMANCE CRITERIA TEST SETUP The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special operating condition is specified in the follows during the testing. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 35 of 59 4.4 ESD TESTING 4.4.1 TEST SPECIFICATION Basic Standard: Discharge Impedance: Required Performance Discharge Voltage: IEC/EN 61000-4-2 330 ohm / 150 pF B Air Discharge:2kV/4kV/8kV (Direct) Contact Discharge:2kV/4kV (Direct/Indirect) Polarity: Number of Discharge: Positive & Negative Air Discharge: min. 20 times at each test point Contact Discharge: min. 200 times in total Single Discharge 1 second minimum Discharge Mode: Discharge Period: 4.4.2 MEASUREMENT INSTRUMENTS Item 1 Kind of Equipment ESD Simulator Manufacturer Type No. Serial No. Calibrated until Noiseken ESS-2002 ESS0625214 06/29/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.4.3 TEST PROCEDURE The test generator necessary to perform direct and indirect application of discharges to the EUT in the following manner: a. Contact discharge was applied to conductive surfaces and coupling planes of the EUT. During the test, it was performed with single discharges. For the single discharge time between successive single discharges was at least 1 second. The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test points. One of the test points shall be subjected to at least 50 indirect discharges to the center of the front edge of the horizontal coupling plane. The remaining three test points shall each receive at least 50 direct contact discharges. If no direct contact test points are available, then at least 200 indirect discharges shall be applied in the indirect mode. Test shall be performed at a maximum repetition rate of one discharge per second. Vertical Coupling Plane (VCP): The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. Horizontal Coupling Plane (HCP): The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. b. Air discharges at insulation surfaces of the EUT. It was at least ten single discharges with positive and negative at the same selected point. c. For the actual test configuration, please refer to the related Item –EUT Test Photos. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 36 of 59 4.4.4 DEVIATION FROM TEST STANDARD No deviation 4.4.5 TEST SETUP Note: TABLE-TOP EQUIPMENT The configuration consisted of a wooden table 0.8 meters high standing on the Ground Reference Plane. The GRP consisted of a sheet of aluminum at least 0.25mm thick, and 2.5 meters square connected to the protective grounding system. A Horizontal Coupling Plane (1.6m x 0.8m) was placed on the table and attached to the GRP by means of a cable with 940k total impedance. The equipment under test, was installed in a representative system as described in section 7 of IEC /EN 61000-4-2, and its cables were placed on the HCP and isolated by an insulating support of 0.5mm thickness. A distance of1-meter minimum was provided between the EUT and the walls of the laboratory and any other metallic structure. FLOOR-STANDING EQUIPMENT The equipment under test was installed in a representative system as described in section 7 of IEC/EN 61000-4-2, and its cables were isolated from the Ground Reference Plane by an insulating support of0.1-meter thickness. The GRP consisted of a sheet of aluminum that is at least 0.25mm thick, and 2.5meters square connected to the protective grounding system and extended at least 0.5 meters from the EUT on all sides. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 37 of 59 4.4.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 23 ℃ Relative Humidity: 51 % Pressure: 1007 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Mode Location 1 2 3 4 5 6 7 8 9 Criteria Result Judgment 2KV P N A A A A A A A A A A 12KV P N 2KV P A A N A A B A PASS Mode Location 1 2 3 4 Criteria Result Judgment Air Discharge 4KV 8KV P N P N A A A A A A A A A A A A A A A A A A A A 2KV P N A A A A A A A A HCP Discharge 4KV 6KV P N P N A A A A A A A A B A PASS Contact Discharge 4KV 6KV P N P N A A A A 8KV P N B A PASS 8KV P N 2KV P A A A A N A A A A VCP Discharge 4KV 6KV P N P N A A A A A A A A B A PASS P 8KV N Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2) Test condition: Direct / Indirect (HCP/VCP) discharges: Minimum 50 times (Positive/Negative) at each point. Air discharges: Minimum 10 times (Positive/Negative) at each point. 3) Test location(s) in which discharge (Air and contact discharge) to be applied illustrated by photos shown in next page(s) 4) The Indirect (HCP/VCP) discharges description of test point as following: 1.left side 2.right side 3.front side 4.rear side 5) N/A - denotes test is not applicable in this test report 7) Criteria B: The EUT function loss during the test, but self-recoverable after the test. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 38 of 59 4.5 RS TESTING 4.5.1 TEST SPECIFICATION Basic Standard: Required Performance Frequency Range: Field Strength: Modulation: Frequency Step: Polarity of Antenna: Test Distance: Antenna Height: Dwell Time: IEC/EN 61000-4-3 A 80 MHz - 1000 MHz 3 V/m 1kHz Sine Wave, 80%, AM Modulation 1 % of fundamental Horizontal and Vertical 3m 1.5 m at least 3 seconds 4.5.2 MEASUREMENT INSTRUMENTS Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Signal Generator R&S SMT 06 832080/007 06/29/2009 2 Power Amplifier(RS) M2S AC8113-800/25 0A 9904-113 06/29/2009 3 Antenna(500W) MESS-ELEKTRONIK VULB9161 4022 06/29/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.5.3 TEST PROCEDURE The EUT and support equipment, which are placed on a table that is 0.8 meter above ground and the testing was performed in a fully-anechoic chamber. The testing distance from antenna to the EUT was 3 meters. The other condition as following manner: a. The field strength level was 3V/m. b. The frequency range is swept from 80 MHz to 1000 MHz, with the signal 80%amplitude modulated with a 1kHz sine wave. The rate of sweep did not exceed 1.5x 10-3 decade/s. Where the frequency range is swept incrementally, the step size was 1% of fundamental. c. The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to respond. d. The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of the four sides. e. For the actual test configuration, please refer to the related Item –EUT Test Photos. 4.5.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 39 of 59 4.5.5 TEST SETUP Note: TABLE-TOP EQUIPMENT The EUT installed in a representative system as described in section 7 of IEC/EN 61000-4-3 was placed on a non-conductive table 0.8 meters in height. The system under test was connected to the power and signal wire according to relevant installation instructions. FLOOR-STANDING EQUIPMENT The EUT installed in a representative system as described in section 7 of IEC/EN 61000-4-3 was placed on a non-conductive wood support 0.1 meters in height. The system under test was connected to the power and signal wire according to relevant installation instructions. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 40 of 59 4.5.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 57 % Pressure: 1004 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Frequency Range RF Field R.F. (MHz) Position Field Strength Azimuth Perform. Criteria Results Judgment A PASS 0 3 V/m (rms) 80MHz - 1000MHz H/V 90 AM Modulated 1000Hz, 80% A 180 270 Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2) N/A - denotes test is not applicable in this test report. 3) Criteria A: There was no change operated with initial operating during the test. 4) Criteria B: The EUT function loss during the test, but self-recoverable after the test. 5) Criteria C: The system shut down during the test. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 41 of 59 4.6 EFT/BURST TESTING 4.6.1 TEST SPECIFICATION Polarity: Impulse Frequency: Impulse Wave shape : IEC/EN 61000-4-4 B Power Line:1 kV Signal/Control Line:0.5 KV Positive & Negative 5 kHz 5/50 ns Burst Duration: Burst Period: Test Duration: 15 ms 300 ms Not less than 1 min. Basic Standard: Required Performance Test Voltage: 4.6.2 MEASUREMENT INSTRUMENTS Item 1 Kind of Equipment EMC Immunity Test System Manufacturer Thermo Type No. EMCPRO PLUS Serial No. Calibrated until 0502214 06/29/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.6.3 TEST PROCEDURE The EUT and support equipment, are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. The other condition as following manner: a. The length of power cord between the coupling device and the EUT should not exceed 1 meter. b. Both positive and negative polarity discharges were applied. c. The duration time of each test sequential was 1 minute d. For the actual test configuration, please refer to the related Item –EUT Test Photos. 4.6.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 42 of 59 4.6.5 TEST SETUP Note: TABLE-TOP EQUIPMENT The configuration consisted of a wooden table (0.8m high) standing on the Ground Reference Plane. The GRP consisted of a sheet of aluminum (at least 0.25mm thick and 2.5m square) connected to the protective grounding system. A minimum distance of 0.5m was provided between the EUT and the walls of the laboratory or any other metallic structure. FLOOR-STANDING EQUIPMENT The EUT installed in a representative system as described in section 7 of IEC/EN 61000-4-4 and its cables, were isolated from the Ground Reference Plane by an insulating support that is 0.1-meter thick. The GRP consisted of a sheet of aluminum (at least 0.25mm thick and 2.5m square) connected to the protective grounding system. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 43 of 59 4.6.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 57 % Pressure: 1004 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Mode ( X ) AC Power Line Test Level Port(s) ( ) DC Power Line 1KV ( ) Signal/Control Line 0.5KV 0.5KV Polarity Results Polarity P A P P N A N N P A P P N A N N P P P N N N Signal/Control P P P Line N N N Line (L) Neutral (N) Ground (PE) Results Polarity Results Criteria B B B Result A N/A N/A Judgment PASS N/A N/A Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2) N/A - denotes test is not applicable in this test report 3) Criteria A: There was no change operated with initial operating during the test. 4) Criteria B: The EUT function loss during the test, but self-recoverable after the test. 5) Criteria C: The system shut down during the test. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 44 of 59 4.7 SURGE TESTING 4.7.1 TEST SPECIFICATION Basic Standard: Required Performance Wave-Shape: Test Voltage: Surge Input/Output: Generator Source: Impedance: Polarity: Phase Angle: Pulse Repetition Rate: Number of Tests: IEC/EN 61000-4-5 B Combination Wave 1.2/50 us Open Circuit Voltage 8 /20 us Short Circuit Current Power Line:0.5 kV, 1 kV, 2 kV L1-L2, L1-PE, L2-PE 2 ohm between networks 12 ohm between network and ground Positive/Negative 0 /90/180/270 1 time / min. (maximum) 5 positive and 5 negative at selected points 4.7.2 MEASUREMENT INSTRUMENTS Item 1 Kind of Equipment EMC Immunity Test System Manufacturer Thermo Type No. EMCPRO PLUS Serial No. Calibrated until 0502214 06/29/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.7.3 TEST PROCEDURE a. For EUT AC ADAPTER: The surge is to be applied to the EUT AC ADAPTER terminals via the capacitive coupling network. Decoupling networks are required in order to avoid possible adverse effects on equipment not under test that may be powered by the same lines, and to provide sufficient decoupling impedance to the surge wave. The power cord between the EUT and the coupling/decoupling networks shall be 2meters in length (or shorter). b. For test applied to unshielded unsymmetrically operated interconnection lines of EUT: The surge is applied to the lines via the capacitive coupling. The coupling /decoupling networks shall not influence the specified functional conditions of the EUT. The interconnection line between the EUT and the coupling/decoupling networks shall be 2 meters in length (or shorter). c. For test applied to unshielded symmetrically operated interconnection /telecommunication lines of EUT: The surge is applied to the lines via gas arrestors coupling. Test levels below the ignition point of the coupling arrestor cannot be specified. The interconnection line between the EUT and the coupling/decoupling networks shall be 2 meters in length (or shorter). d. For the actual test configuration, please refer to the related Item –EUT Test Photos. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 45 of 59 4.7.4 DEVIATION FROM TEST STANDARD No deviation 4.7.5 TEST SETUP ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 46 of 59 4.7.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 57 % Pressure: 1004 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Wave Form EUT Ports Tested Polarity +/+/- 90° A A +/- 180° A A +/- 270° A A L-N 0 +/- 90° +/- 180° +/- 270° +/- 0° +/- 90° +/- 180° +/- 270° +/- 0° +/- 90° +/- 180° +/- 270° +/- 0° +/- 90° +/- 180° +/- 270° N - PE Signal Line (N/A) Criteria Judgment B PASS B N/A B N/A B N/A B N/A 2kV ° +/L - PE Signal Line (N/A) 1.2/50(8/20)Ti/Th us Voltage Phase 0.5kV 1kV 1.5kV A A 0° Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2) Polarity and Numbers of Impulses:5 Pst / Ngt at each tested mode 3) N/A - denotes test is not applicable in this Test Report 4) All voltages of the lower levels shall be satisfied ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 47 of 59 4.8 INJECTION CURRENT TESTING 4.8.1 TEST SPECIFICATION Basic Standard: Required Performance Frequency Range: Field Strength: Modulation: Frequency Step: Dwell Time: IEC/EN 61000-4-6 A 0.15 MHz - 80 MHz 3 Vr.m.s. 1kHz Sine Wave, 80%, AM Modulation 1 % of fundamental at least 3 seconds 4.8.2 MEASUREMENT INSTRUMENTS Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Signal Generator IFR 2023A 202301/368 06/29/2008 2 Power Amplifier(CS) M2S A0122-250 9902-111 06/29/2008 3 CDN MEB M3 13389 06/29/2008 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.8.3 TEST PROCEDURE The EUT and support equipment, are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. The other condition as following manner: a. The field strength level was 3V. b. The frequency range is swept from 150 KHz to 80 MHz, with the signal 80%amplitude modulated with a 1kHz sine wave. The rate of sweep did not exceed 1.5x 10-3 decade/s. Where the frequency range is swept incrementally, the step size was 1% of fundamental. c. The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to respond. d. For the actual test configuration, please refer to the related Item –EUT Test Photos. 4.8.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 48 of 59 4.8.5 TEST SETUP For the actual test configuration, please refer to the related Item –EUT Test Photos. NOTE: FLOOR-STANDING EQUIPMENT The equipment to be tested is placed on an insulating support of 0.1 meters height above a ground reference plane. All relevant cables shall be provided with the appropriate coupling and decoupling devices at a distance between 0.1 meters and 0.3 meters from the projected geometry of the EUT on the ground reference plane. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 49 of 59 4.8.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 57 % Pressure: 1004 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Test Ports (Mode) Input/ Output Freq. Range MHz) Field Strength 0.15 ---80 Perform. Results Judgment A A PASS A N/A N/A A N/A N/A A N/A N/A Criteria AC. Power Port Input/ Output 0.15 --- 80 DC. Power Port 3V(rms) AM Modulated Signal Line 0.15 --- 80 ( N/A ) Signal Line 1000Hz, 80% 0.15 --- 80 ( N/A ) Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2) N/A - denotes test is not applicable in this Test Report. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 50 of 59 4.9 POWER FREQUENCY MAGNETIC FIELD TESTING 4.9.1 TEST SPECIFICATION Basic Standard: Required Performance Frequency Range: Field Strength: Observation Time: Inductance Coil: IEC/EN 61000-4-8 A 50Hz 1 A/m 1 minute Rectangular type, 1mx1m 4.9.2 MEASUREMENT INSTRUMENTS Item 1 Kind of Equipment Magnetic Field Test Generator Manufacturer FCC Type No. F-100-4-8-G-1 25A Serial No. Calibrated until 04032 06/27/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.9.3 TEST PROCEDURE The EUT and support equipment, are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. The other condition as following manner: a. The equipment cabinets shall be connected to the safety earth directly on the GRP via the earth terminal of the EUT. b. The cables supplied or recommended by the equipment manufacturer shall be used. 1 meter of all cables used shall be exposed to the magnetic field. c. For the actual test configuration, please refer to the related Item –EUT Test Photos. 4.9.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 51 of 59 4.9.5 TEST SETUP Note: TABLE-TOP EQUIPMENT The equipment shall be subjected to the test magnetic field by using the induction coil of standard dimension (1 m x 1 m). The induction coil shall then be rotated by 90 degrees in order to expose the EUT to the test field with different orientations. FLOOR-STANDING EQUIPMENT The equipment shall be subjected to the test magnetic field by using induction coils of suitable dimensions. The test shall be repeated by moving and shifting the induction coils, in order to test the whole volume of the EUT for each orthogonal direction. The test shall be repeated with the coil shifted to different positions along the side of the EUT, in steps corresponding to 50 % of the shortest side of the coil. The induction coil shall then be rotated by 90 degrees in order to expose the EUT to the test field with different orientations. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 52 of 59 4.9.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 57 % Pressure: 1004 hPa Test Power : AC 230V/50Hz Test Mode : Full Load Duration Perform (s) Criteria X 30 s A A PASS 1 A/m Y 30 s A A PASS 1 A/m Z 30 s A A PASS Test Mode Test Level Antenna aspect Enclosure 1 A/m Enclosure Enclosure Results Judgment Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2) N/A - denotes test is not applicable in this test report ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 53 of 59 4.10 VOLTAGE INTERRUPTION/DIPS TESTING 4.10.1 TEST SPECIFICATION Basic Standard: Required Performance: Test Duration Time: Interval between Event: Phase Angle: Test Cycle: IEC/EN 61000-4-11 B (For >95% Voltage Dips) C (For 30% Voltage Dips) C (For >95% Voltage Interruptions) Minimum three test events in sequence Minimum ten seconds 0°/45°/90°/135°/180°/225°/270°/315°/360° 3 times 4.10.2 MEASUREMENT INSTRUMENTS Item 1 Kind of Equipment EMC Immunity Test System Manufacturer Thermo Type No. EMCPRO PLUS Serial No. Calibrated until 0502214 06/27/2009 Remark: ” N/A” denotes No Model No. / Serial No. and No Calibration specified. 4.10.3 TEST PROCEDURE The EUT shall be tested for each selected combination of test levels and duration with a sequence of three dips/interruptions with intervals of 10 s minimum (between each test event). Each representative mode of operation shall be tested. Abrupt changes in supply voltage shall occur at zero crossings of the voltage waveform. 4.10.4 DEVIATION FROM TEST STANDARD No deviation ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 54 of 59 4.10.5 TEST SETUP For the actual test configuration, please refer to the related Item –EUT Test Photos. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 55 of 59 4.10.6 TEST RESULTS EUT: AC ADAPTER Model No. : ZB-01-5020 Temperature: 26 ℃ Relative Humidity: 48% Pressure: 1004hPa Test Power : AC 230V/50Hz Test Mode : Full Load Voltage Periods Reduction Perform Criteria Results Judgment Voltage dip >95% 0.5 B A PASS Voltage dip 30% 25 C A PASS 250 C C PASS Interruption>95% Note: 1) P/N denotes the Positive/Negative polarity of the output voltage. 2). N/A - denotes test is not applicable in this test report. ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 56 of 59 EUT Photo Type of equipment, model: ZB-18USB [ x ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom View: [ x ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 57 of 59 View: [ x ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom View: [ x ] general [ ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 58 of 59 View: [ ] general [ x ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom View: [ ] general [ x ] front [ ] rear [ ] right [ ] left [ ] top [ ] bottom ATT Product Service Co., Ltd 2 F., B2/B3 Area, City Plaza, ChangAn Town, DongGuan City, GuangDong, P.R.China Phone: 86-769-8509 8000; Fax: 86-769 8509 8777 Report NO.:10808002E Page: 59 of 59
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2009:12:05 10:43:49+08:00 Create Date : 2009:12:05 10:43:49+08:00 Format : application/pdf Title : E:\研发2009\[客户资料\ZB-01\ZB-01 EMC Report.doc Creator : Administrator Document ID : uuid:0d25d6cd-0fc3-408f-b0f9-ac3e2a01bdfa Instance ID : uuid:7d6c40b4-42f0-4ff1-a7c4-734d269dac68 Page Count : 59 Author : AdministratorEXIF Metadata provided by EXIF.tools