StrideLinx Industrial VPN Router User Manual Appendix F Appxf
User Manual: Pdf Appendix F StrideLinx Series Industrial VPN Router - AutomationDirect
Open the PDF directly: View PDF
.
Page Count: 6
| Download | |
| Open PDF In Browser | View PDF |
Capabilities of Connected AutomationDirect Devices In this Appendix... Appendix F Network Topology.......................................................................................................F-2 Network with StrideLinx VPN router using wired or WiFi network connectivity..........F-3 Network with StrideLinx VPN router using 4G cellular network connectivity..............F-4 Device Capabilities......................................................................................................F-5 Linx E F 3 4 5 6 7 8 9 10 11 12 13 14 A B C D Appendix F: Capabilities of Connected AutomationDirect Devices Network Topology F-2 To facilitate description of the capabilities of various AutomationDirect product lines when connected to a StrideLinx VPN router, the overall topology of a network connecting plant devices to the StrideLinx platform can be divided into three zones, as illustrated in the two figures later in this appendix. The zones are defined as follows. • Zone 1 is outside the company network, and includes the StrideLinx platform and secure connections to it from various devices. • Zone 2 is the company network, which exists behind a corporate firewall. This zone may include various computer systems, but is isolated from the plant/controls network by the internal firewall of the VPN router. • Zone 3 comprises the devices connected to the VPN router, and thus potentially capable of secure remote connection. NOTE: Zone 2 does not participate at all in StrideLinx communications when a 4G cellular connection is used on the VPN router, since the 4G connection does not traverse the company network. StrideLinx™ Industrial VPN Routers User Manual 1st Edition, Rev. C Appendix F: Capabilities of Connected AutomationDirect Devices Network with StrideLinx VPN router using wired or WiFi network connectivity Zone 1 Linx Linx HTTPS Connection Linx VPN Connection Zone 2 Outgoing Connection Linx Corporate Servers Linx Corporate Fire Wall Company Network Linx Company WiFi Internal Fire Wall Zone 3 VPN router PLC EtherNet/IP Devices Ethernet Plant/Controls Network HMI Plant WiFi Hand-held Scanner VFD/Motor Application PLC StrideLinx™ Industrial VPN Routers User Manual Field I/O 1st Edition, Rev. C Linx E F 3 4 5 6 7 8 9 10 11 12 13 14 A B C D F-3 Linx Appendix F: Capabilities of Connected AutomationDirect Devices Network with StrideLinx VPN router using 4G cellular network connectivity F-4 Zone 1 Linx Linx HTTPS Connection Linx VPN Connection Linx Linx Zone 2 4G Cellular Connection Internal Fire Wall Zone 3 4G VPN router Plant/Controls Network PLC EtherNet/IP Devices Ethernet E F 3 4 5 6 7 8 9 10 11 12 13 14 A B C D HMI Plant WiFi Linx Hand-held Scanner VFD/Motor Application PLC StrideLinx™ Industrial VPN Routers User Manual Field I/O 1st Edition, Rev. C Appendix F: Capabilities of Connected AutomationDirect Devices Device Capabilities The following table describes the capabilities of devices to establish communications connections across various network zones, as defined earlier. Communications Capabilities of Devices Connected to StrideLinx Router Functionality Zone 1->3 (StrideLinx App or Browser w/o VPN) Zone 1->3 (VPN) Zone 2->3 1,6 Zone 3->2 6 Zone 3->1 Zone 3->3 Generic PLC programming SW (Windows) N Y Y NA NA Y Productivity programming SW N Y Y NA NA Y BRX programming SW N Y Y NA NA Y C-more programming SW N Y Y NA NA Y C-more Remote Access (PC) N Y Y NA NA Y PxK/C-more web server Y4 Y Y NA NA Y PxK/C-more FTP access (into PxK/C-more) N Y Y NA NA Y BRX/PxK/C-more Email to Server (sent from BRX/PxK/C-more) NA NA NA Y2 Y2 NA PxK/C-more FTP to PC (sent from PxK/C-more) NA NA NA Y2 Y2 NA PxK/C-more mobile app (connect by WiFi) N N Y3 NA NA Y 3rd party PLC or HMI web/VNC server Y5 Y Y NA NA Y Windows-based machine control N Y Y NA NA Y 2nd StrideLinx Router (M2M or site-to-site) NA NA NA NA N NA 1. Connections from Zone 2 to 3 can be made through VPN on a PC but require firewall adjustments (port forwarding) for other devices. Consideration for security should be made before making firewall adjustments. 2. StrideLinx router firewall must be configured to allow internet access from the LAN side or allow access to corporate network. This data does not pass through the VPN tunnel. 3. StrideLinx router firewall must be configured to allow access to corporate network in order for the C-more Mobile App to connect. 4. PxK/C-more web server must be configured in StrideLinx platform (services tab) to provide the shortcut on the router dashboard page. 5. Web/VNC server capability depends on 3rd party device capability. Web/VNC server must be configured in StrideLinx platform (services tab) to provide the shortcut on the router dashboard page. 6. Connections to/from Zone 2 are not applicable when using a 4G cellular connection. 7. NA is used when the device is not located in the starting or ending zone. NOTE: The StrideLinx router & platform should operate with any TCP/UDP Ethernet device designed with remote connectivity functions such as unicast messaging, default gateway support and retry timeout parameters. ADC tech support can assist with basic networking/connectivity troubleshooting for any device connected to a StrideLinx router, but only officially supports ADC hardware and programming software tools. StrideLinx™ Industrial VPN Routers User Manual 1st Edition, Rev. C E F 3 4 5 6 7 8 9 10 11 12 13 14 A B C D F-5 Linx Appendix F: Capabilities of Connected AutomationDirect Devices E F 3 4 5 6 7 8 9 10 11 12 13 14 A B C D F-6 StrideLinx™ Industrial VPN Routers User Manual 1st Edition, Rev. C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : AutomationDirect Create Date : 2018:05:02 14:40:07-04:00 Modify Date : 2018:05:17 14:55:08-04:00 Subject : StrideLinx Remote Access Solution Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Title : StrideLinx Industrial VPN Router User Manual Creator : AutomationDirect Description : StrideLinx Remote Access Solution Metadata Date : 2018:05:17 14:55:08-04:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:029f8a11-d6f0-462b-a69b-fc383791ecd9 Original Document ID : xmp.did:AC8300A79C14E311B497E908AC6DEAF6 Document ID : xmp.id:12e208af-7ae2-f44b-92c5-327d65352905 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:38c5d804-aa6f-874c-ace9-aa2bf09ee382 Derived From Document ID : xmp.did:2caa773e-5446-6244-bcb8-6970ebda2322 Derived From Original Document ID: xmp.did:AC8300A79C14E311B497E908AC6DEAF6 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2018:05:02 14:40:07-04:00 Producer : Adobe PDF Library 15.0 Trapped : False Page Layout : SinglePage Page Mode : UseOutlines Page Count : 6EXIF Metadata provided by EXIF.tools