Ftp://ftp.zenex.pl/katalogi/schneider/5_systemy_automatyki_i_bezpieczenstwa_w_budynkach/5_1_andover_continuum/pdf/instrukcje_materialy_techniczne/i2_200_controller_installation_instructions.en I2 200 Controller Installation Instructions.en
User Manual: Pdf ftp://ftp.zenex.pl/katalogi/schneider/5_systemy_automatyki_i_bezpieczenstwa_w_budynkach/5_1_andover_continuum/pdf/instrukcje_materialy_techniczne/i2_200_controller_installation_instructions.en instructions pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Mechanical 2.75 (70) 7.5 (191) 200 Installation 30-3001-786 Rev H 4.870 (124) 0.33 (8) 5.5 (140) 6.5 (165) RS-232 RS-485 + RD RD TD RD TD TD 5 SHLD + RD TD RD TD RD TD 3 SHLD + UL864 SMOKE CONTROL NOTICE 6.67 (170) In UL864 Installations (Smoke Control), this cabinet must be surface mounted only. 2 - 7.625 (194) 300 1200 2400 9600 19200 38400 76800 SPARE 1 2 3 4 5 6 7 8 8.0 (203) + 8.5 (216) BAUD RATE 4 SHLD SHLD + POWER 1 SHLD (INPUT) ENCLOSED-CLASS MOUNTING DIMENSIONS OPEN-CLASS * MOUNTING DIMENSIONS 0.19 (5) * OPEN-CLASS MOUNTING: This equipment is intended for field installation within a UL-listed enclosure. Power Connection WHITE NEUTRAL USE COPPER CONDUCTORS ONLY BLACK HOT USE COPPER CONDUCTORS ONLY 115/230 VAC ~ 50/60 HZ, 3 VA AC MAINS 24 V --1.0 W L +V N -V LINE VOLTAGE 115V SELECTOR GREEN EARTH GROUND + 24 VDC ! USE GROUND STUDS PROVIDED INSIDE CHASSIS FOR EARTH GROUND 115V SETTING 115V Use care when attaching power wiring (AC or DC) to these connectors. They are not to be used as a strain relief. The connectors cannot withstand excessive bending or flexing. USE GROUND STUDS PROVIDED INSIDE CHASSIS FOR EARTH GROUND 230V 230V SETTING 200ac 200dc Signal Connection RS485 4000 ft (max.) 1219 m (max.) RS485 4000 ft (max.) 1219 m (max.) RS485 4000 ft (max.) 1219 m (max.) RS485 4000 ft (max.) 1219 m (max.) 2 3 Note: These circuits are Supervised. 4 5 200 RS232 1 (INPUT) RS485 Wiring Rules Building Ground Requirements High voltage AC Power wiring should be routed to the conduit opening nearest the AC power terminals. Do not bundle or route AC Power wiring with low voltage input or output wiring. Be absolutely certain that your installation complies with all aspects of the National Electric Code, NFPA 70. Be especially sure that your system is properly grounded. Cable Recommendations: RS-485: 22-24 AWG blanced, twisted-pair cable with braided shield Be sure that all equipment from Schneider Electric is grounded to true earth ground. True Earth ground protects the equipment from transients and other power surges in the area. Special studs are pressed into the inside of the chassis for use as a ground connection. We cannot guarantee that the controller system will operate as documented without a properly grounded installation. An example of a sub-standard ground is a galvanized steel cold water pipe. As the pipe corrodes, it does not act as a true ground. The corrosion acts as an insulator, raising the potential of the pipe with respect to the ground. Caution: Earth ground ( ) must be connected to avoid module damage. ! RS485 Connections Communications Baud Rate RS485 NETWORK ACTIVITY INDICATORS BAUD RATE WHITE + SHLD TD 1 (INPUT) SHIELD 34 5 6 7 8 - RD 1 2 BLACK 300 1200 2400 9600 19200 38400 76800 SPARE To select a baud rate, slide the appropriate switch to the right. Warning: Only one switch may be activated at a time. If no switch is selected unit will not operate. All connected network rates must be the same. RS485 InfiNet I speed is limited to 19200 RS232 Connections System Indicators/Controls 1 POWER indicates that the proper power is applied to the unit. PIN 1: CHASSIS GROUND PIN 7: SIGNAL GROUND PIN 2: TRANSMIT DATA PIN 9: +12VDC @ 25mA PIN 3: RECEIVE DATA PIN 10: -12VDC @ 25mA PIN 4: ENABLE PIN 20: ENABLE POWER © 2010 Schneider Electric, All Rights Reserved. Schneider Electric - One High Street - North Andover MA USA 01845
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2EXIF Metadata provided by EXIF.tools