NUFLO MC III WP Flow Analyzer Technical Data Sheet
User Manual: Pdf NUFLO MC-III WP Flow Analyzer Technical Data Sheet Resource Library
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
TECHNICAL SPECIFICATIONS NUFLO MC-III WP Flow Analyzer Cameron’s NUFLOTM MC-IIITM WP Flow Analyzer offers state-of-the art liquid and gas measurement with data logging and Modbus® communications in an easy-to-use weatherproof totalizer. With the capacity to record up to 384 daily flow logs, 768 hourly logs, and 345 event logs, the MC-III WP is a powerful addition to any flow measurement operation. Features The MC-III WP offers: • R S-485 Modbus communications • Extensive log archival capacity • High-speed downloads (less than • Simultaneous indication of rate and total • • • • a minute, based on 115 K baud) • E asy-to-read LCD displays • 12-point linearization Loop-powered analog output Nonvolatile memory Password-protected security options Direct or remote mount Keypad Configuration The MC-III WP is easily configured with the six-button keypad on the front of the instrument. Built-in shortcuts to common functions (see figure below) reduce the user’s time spent on-site. MENU OUTPUT MENU DISPLAY MENU Calibration Calibrating the MC-III WP Configure 4 to 20 mA output and pulse output Enter slave address and baud rate Calibrate instrument Set flow meter input sensitivity K-FACTOR Select pulse input Modbus communication, logging and accurate flow measurement – all in one compact weatherproof device Each unit is supplied with one conduit hub for I/O access; two seals can be replaced with additional hubs (as shown). for liquid measurement is as Set engineering units and decimal positions for total and rate readout easy as entering the calibration factor of the flow meter and selecting the desired units of measurement. The instrument automatically calculates its own divisor. ENTER LOG Navigate menus Access daily volume archive TEST SAVE Enter/change values and decimal positions Toggle on/off settings Test temperature and system voltage Save calibration settings and totals Zero the total readout (by pressing the log and save keys simultaneously) Inputs/Outputs The MC-III WP connects to a turbine meter or a pre-amplifier. Users can select a 4 to 20 mA output, a pulse output, or an amplified flow meter frequency output that allows remote equipment to calculate flow rates and volume. When the instrument is paired with a gas flow meter, the user enters the calibration factor of the meter, pressure and temperature parameters and FPV via the MC-III interface software. The wide variety of unit options for total and rate gives users the freedom to customize the display, inputs and outputs for specific needs. Display • E ight-digit display of total • Six-digit display of rate (11-segment characters for easy-to-read prompts) • C haracter height - 0.300” • Adjustable contrast and update period • User-selectable units of measurement: Total: bbl, gal, liters, cubic meters, cubic feet, standard cubic feet, user-defined units (and all units x 1000) ate: Any of the above R total engineering units per day, hour, minute, or second Power Supply Options • 3.6 VDC lithium battery pack Remote Reset Input • Optically isolated • Supply range: 3.0 to 30 VDC Pulse Input • O ptically isolated • S upply range: 3.0 to 30 VDC Outputs Analog Output • 4 to 20 mA, loop-powered (two-wire) • 1 6-bit resolution • A ccuracy: 0.1% of FS at 25°C, 50 PPM/°C temperature drift • L oop power: 8.0 to 30 VDC • Zero and full-scale engineering values configurable from front panel RS-485 Communications • Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and up to 115.2K T wo-year typical life (main or backup power supply) T ransport is subject to hazardous goods restrictions • Alkaline battery pack option Volumetric Pulse Output • S olid-state relay • O utput rating: 60 mA max at 30 VDC (main or backup power supply) • External power supply (6 to 30 VDC) with internal battery backup • Loop-powered (4 to 20 mA output) with internal battery backup Temperature Range • Configurable pulse duration • LCD contrast is reduced below -20° C Inputs Turbine Meter Input • C onfigurable sensitivity adjustment • Frequency range: 0 to 3500 Hz K-factor changes Input setting changes Communications/ Archive Retrieval • R TU mode Modbus • Enron Modbus • 16-bit slave address supported • Data printouts in tabular or chart formats • Data export to spreadsheet (.xls and .csv formats) MC-III Interface Software • Provided at no additional charge • Complete configuration to include multipoint and gas calibration • Real-time data • Downloads Reports Amp and Square Output Charts • Open-drain transistor output of turbine meter input signal • Output rating: 50 mA at 30 VDC (analog output and amp and square outputs cannot be used simultaneously) (-40° C to 70° C) (-18° C to 55° C) • 3 84 daily logs • 768 hourly logs • 345 event logs and scale factor • Lithium battery: -40° F to 158° F • Alkaline battery pack: 0° F to 130° F Flow Archive Certification • • • • CSA approved for US and Canada E xports to .xls and .csv formats • Wizard offers step-by-step calibration procedure • Windows® 2000 or XP required L O C AT I O N S North and South America 14450 JFK Blvd. Houston, TX 77032 USA Tel 1 281 582.9500 ms-us@c-a-m.com Europe, Africa, Caspian and Russia 3 Steyning Way Southern Cross Trading Estate Bognor Regis West Sussex PO22 9TT England, UK Tel 44 1243 826741 ms-uk@c-a-m.com Asia Pacific Suite 16.02 Menara AmFirst No. 1 Jalan 19/3 46300 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 603 7954 0145 ms-kl@c-a-m.com Middle East Level 9, Al Jazira Club Tower A PO Box 47280, Muroor Road Abu Dhabi United Arab Emirates Tel 971 2 596 8400 ms-uk@c-a-m.com O t h e r locations ALGERIA C A N A DA CHINA INDIA M A L AYS I A Class I, Div. 2, Groups A, B, C, D R U SS I A Type 4 enclosure UA E Type 5 temperature class UK USA www.c-a-m.com/measurement © Copyright 2013 | NUFLO and MC-III are trademarks of Cameron. Modbus is a registered trademark of the Modbus Organization, Inc. Windows is a registered trademark of Microsoft. All Rights Reserved. | SWP 09/13 AD01095M
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2013:09:27 11:36:15-05:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2013:09:27 12:46:48-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:09:27 12:46:48-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:03c9726a-f786-e74c-86c6-2368c6e18442 Original Document ID : xmp.did:0480117407206811822A95473FED6B20 Document ID : xmp.id:0F0E8BFCF92168118A6DD409643A7CC3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:0E0E8BFCF92168118A6DD409643A7CC3 Derived From Document ID : xmp.did:5758EFA7222468118A6DD227A30CB1DC Derived From Original Document ID: xmp.did:0480117407206811822A95473FED6B20 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:09:27 11:36:15-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2EXIF Metadata provided by EXIF.tools