NUFLO MC III WP Flow Analyzer Technical Data Sheet

User Manual: Pdf NUFLO MC-III WP Flow Analyzer Technical Data Sheet Resource Library

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadNUFLO MC-III WP Flow Analyzer Technical Data Sheet Nuflo-mc-iii-wp-flow-analyzer
Open PDF In BrowserView PDF
TECHNICAL SPECIFICATIONS

NUFLO MC-III WP Flow Analyzer
Cameron’s NUFLOTM MC-IIITM WP Flow Analyzer offers state-of-the art liquid and gas measurement
with data logging and Modbus® communications in an easy-to-use weatherproof totalizer.
With the capacity to record up to 384 daily flow logs, 768 hourly logs, and 345 event logs,
the MC-III WP is a powerful addition to any flow measurement operation.

Features
The MC-III WP offers:

• R S-485 Modbus communications
• Extensive log archival capacity
• High-speed downloads (less than

• Simultaneous indication of rate
and total

•
•
•
•

a minute, based on 115 K baud)

• E asy-to-read LCD displays
• 12-point linearization

Loop-powered analog output
Nonvolatile memory
Password-protected security options
Direct or remote mount

Keypad Configuration
The MC-III WP is easily configured with the six-button keypad on the front of the
instrument. Built-in shortcuts to common functions (see figure below) reduce the user’s
time spent on-site.

MENU

OUTPUT
MENU

DISPLAY
MENU

Calibration
Calibrating the MC-III WP

Configure 4 to 20 mA output and pulse output
Enter slave address and baud rate
Calibrate instrument
Set flow meter
input sensitivity
K-FACTOR
Select pulse input

Modbus communication,
logging and accurate
flow measurement –
all in one compact
weatherproof device
Each unit is supplied with
one conduit hub for I/O
access; two seals can be
replaced with additional
hubs (as shown).

for liquid measurement is as
Set engineering
units and decimal
positions for total
and rate readout

easy as entering the calibration factor of
the flow meter and selecting the desired
units of measurement. The instrument
automatically calculates its own divisor.

ENTER
LOG
Navigate menus
Access daily
volume archive

TEST

SAVE

Enter/change values and decimal positions
Toggle on/off settings
Test temperature and system voltage

Save calibration
settings and totals
Zero the total
readout (by pressing
the log and save
keys simultaneously)

Inputs/Outputs
The MC-III WP connects to a turbine meter or
a pre-amplifier. Users can select a 4 to 20 mA
output, a pulse output, or an amplified flow
meter frequency output that allows remote
equipment to calculate flow rates and volume.

When the instrument is paired with a
gas flow meter, the user enters the
calibration factor of the meter, pressure
and temperature parameters and FPV via
the MC-III interface software. The wide
variety of unit options for total and rate
gives users the freedom to customize
the display, inputs and outputs for
specific needs.

Display
• E ight-digit display of total
• Six-digit display of rate
(11-segment characters for
easy-to-read prompts)

• C
 haracter height - 0.300”
• Adjustable contrast and
update period

• User-selectable units of
measurement:
Total: bbl, gal, liters,
cubic meters, cubic
feet, standard cubic feet,
user-defined units (and
all units x 1000)
 ate: Any of the above
R
total engineering units
per day, hour, minute,
or second

Power Supply Options
• 3.6 VDC lithium battery pack

Remote Reset Input

• Optically isolated
• Supply range: 3.0 to 30 VDC
Pulse Input

• O
 ptically isolated
• S upply range: 3.0 to 30 VDC

Outputs
Analog Output

• 4 to 20 mA, loop-powered
(two-wire)

• 1 6-bit resolution
• A
 ccuracy: 0.1% of FS at 25°C,
50 PPM/°C temperature drift

• L oop power: 8.0 to 30 VDC
• Zero and full-scale engineering
values configurable from
front panel
RS-485 Communications

• Baud rates: 300, 600, 1200,
2400, 4800, 9600, 19200,
38400, 57600 and up
to 115.2K

T wo-year typical life (main or
backup power supply)
T ransport is subject to
hazardous goods restrictions

• Alkaline battery pack option

Volumetric Pulse Output

• S olid-state relay
• O
 utput rating: 60 mA max
at 30 VDC

(main or backup power supply)

• External power supply (6 to
30 VDC) with internal
battery backup

• Loop-powered (4 to 20 mA output)
with internal battery backup

Temperature Range

• Configurable pulse duration

• LCD contrast is reduced
below -20° C

Inputs
Turbine Meter Input

• C
 onfigurable sensitivity adjustment
• Frequency range: 0 to 3500 Hz

K-factor changes
Input setting changes

Communications/
Archive Retrieval
• R TU mode Modbus
• Enron Modbus
• 16-bit slave address
supported

• Data printouts in
tabular or chart formats

• Data export to
spreadsheet
(.xls and .csv formats)

MC-III Interface
Software
• Provided at no
additional charge

• Complete configuration
to include multipoint
and gas calibration

• Real-time data
• Downloads
Reports

Amp and Square Output

Charts

• Open-drain transistor output
of turbine meter input signal

• Output rating: 50 mA at 30
VDC (analog output and amp
and square outputs cannot be
used simultaneously)

(-40° C to 70° C)
(-18° C to 55° C)

• 3 84 daily logs
• 768 hourly logs
• 345 event logs

and scale factor

• Lithium battery: -40° F to 158° F
• Alkaline battery pack: 0° F to 130° F

Flow Archive

Certification
•
•
•
•

CSA approved for US and Canada

E xports to .xls and
.csv formats

• Wizard offers step-by-step
calibration procedure

• Windows® 2000 or
XP required

L O C AT I O N S
North and South America
14450 JFK Blvd.
Houston, TX 77032
USA
Tel 1 281 582.9500
ms-us@c-a-m.com
Europe, Africa, Caspian and Russia
3 Steyning Way
Southern Cross Trading Estate
Bognor Regis
West Sussex PO22 9TT
England, UK
Tel 44 1243 826741
ms-uk@c-a-m.com
Asia Pacific
Suite 16.02 Menara AmFirst
No. 1 Jalan 19/3
46300 Petaling Jaya
Selangor Darul Ehsan
Malaysia
Tel 603 7954 0145
ms-kl@c-a-m.com
Middle East
Level 9, Al Jazira Club Tower A
PO Box 47280, Muroor Road
Abu Dhabi
United Arab Emirates
Tel 971 2 596 8400
ms-uk@c-a-m.com
O t h e r locations
ALGERIA
C A N A DA
CHINA
INDIA
M A L AYS I A

Class I, Div. 2, Groups A, B, C, D

R U SS I A

Type 4 enclosure

UA E

Type 5 temperature class

UK
USA
www.c-a-m.com/measurement

© Copyright 2013 | NUFLO and MC-III are trademarks of Cameron. Modbus is a registered trademark of the Modbus Organization, Inc. Windows is a registered trademark of Microsoft. All Rights Reserved. | SWP 09/13 AD01095M



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2013:09:27 11:36:15-05:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2013:09:27 12:46:48-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:09:27 12:46:48-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:03c9726a-f786-e74c-86c6-2368c6e18442
Original Document ID            : xmp.did:0480117407206811822A95473FED6B20
Document ID                     : xmp.id:0F0E8BFCF92168118A6DD409643A7CC3
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:0E0E8BFCF92168118A6DD409643A7CC3
Derived From Document ID        : xmp.did:5758EFA7222468118A6DD227A30CB1DC
Derived From Original Document ID: xmp.did:0480117407206811822A95473FED6B20
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2013:09:27 11:36:15-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu